Loading...
HomeMy WebLinkAboutARB202000116 Staff Report 2020-12-09ARCHITECTURAL REVIEW BOARD STAFF REPORT Project #/Name ARB-2020-106 and -116: Albemarle Business Campus Review Type Initial Site Development Plan and first review of an architectural design Parcel Identification 07600-00-00-046AO and 07600-00-00-05400 and 07600-00-00-046FO (part) Location Rt. 631 at Rt. 780 (See Figure 1.) Zoned Residential (R2) / Entrance Corridor (EC) Owner/Applicant 51 Street Forest LLC / Shimp Engineering (Justin Shimp) Magisterial District Samuel Miller Proposal To construct a mixed -use development consisting of apartments, retail and office buildings, a hotel and a self -storage building. Context The surrounding area includes the County Office Building at 5 h Street, apartment communities, and the Region Ten Community Services Board office building, as well as single family detached residences. Visibility All the buildings in the portion of the development located east of Old Lynchburg Road, including the storage building, will be readily visible from the 51 Street Entrance Corridor. The apartment buildings proposed for the portion of the development west of Old Lynchburg Road are located further from the EC street (over 400' away), with some residences and wooded area between, but the 3- and 4-story heights will make the apartment buildings visible above and beyond the smaller scale residences that are closer to 51 Street. ARB Meeting Date December 7, 2020 Staff Contact Margaret Maliszewski PROJECT HISTORY The ARB has reviewed no previous proposals for this site. A rezoning (ZMA-2019-03) was approved for this property in October 2020. ANALYSIS Gray highlight = means the guideline can't be reviewed at initial site plan stage, but recommendations can be provided for final Yellow highlight = means the guideline can only be reviewed for location/configuration at the initial plan stage Regular text = means the guideline can be reviewed at initial plan stage, can be made a condition of initial plan approval, and can be the basis for denial REF GUIDELINE I ISSUE I RECOMMENDATION Pu ose; ConwadbUily with significant historic sues; Comw ilify with the character of the Entrance Corridor; Structure design I The goal of the regulation of the design of development within the The brick and its use at the base of Revise the storage designated Entrance Corridors is to insure that new development within the the building, and the treatments building design to corridors reflects the traditional architecture of the area. Therefore, it is the related to the comer entrance provide greater purpose of ARB review and of these Guidelines, that proposed elements have a basis in traditional organization and unity development within the designated Entrance Corridors reflect elements of architecture, but the overall design among the various design characteristic of the significant historical landmarks, buildings, and does not reflect the traditional building elements. structures of the Charlottesville and Albemarle area, and to promote orderly architecture of the area. The vinyl and attractive development within these corridors. Applicants should note film -covered windows, the that replication of historic structures is neither required nor desired. placement of CMU panels, the extensive use of EIFS, the extent of 2 Visitors to the significant historical sites in the Charlottesville and Albemarle area experience these sites as ensembles of buildings, land, and the brick bases on the side vegetation. In order to accomplish the integration of buildings, land, and elevations, the minimal height vegetation characteristic of these sites, the Guidelines require attention to increase of the corner storefront four primary factors: compatibility with significant historic sites in the area; elements and the lack of returns at the character of the Entrance Corridor; site development and layout; and the tops of those elements are non - landscaping. traditional features that outweigh the traditional components. The number 3 New structures and substantial additions to existing structures should respect the traditions of the architecture of historically significant buildingi and variety of elements do not in the Charlottesville and Albemarle area. Photographs of historic buildingi contribute to an overall unified in the area, as well as drawings of architectural features, which provide appearance. important examples of this tradition are contained in Appendix A. 4 The examples contained in Appendix A should be used as a guide for building design: the standard of compatibility with the area's historic structures is not intended to impose a rigid design solution for new development. Replication of the design of the important historic sites in the area is neither intended nor desired. The Guideline's standard of compatibility can be met through building scale, materials, and forms which may be embodied in architecture which is contemporary as well as traditional. The Guidelines allow individuality in design to accommodate varying tastes as well as special functional requirements. 5 It is also an important objective of the Guidelines to establish a pattern of compatible architectural characteristics throughout the Entrance Corridor in order to achieve unity and coherence. Building designs should demonstrate sensitivity to other nearby structures within the Entrance Corridor. Where a designated corridor is substantially developed, these Guidelines require striking a careful balance between harmonizing new development with the existing character of the corridor and achieving compatibility with the significant historic sites in the area. 9 Building forms and features, including roofs, windows, doors, materials, colors and textures should be compatible with the forms and features of the significant historic buildings in the area, exemplified by (but not limited to) the buildings described in Appendix A [of the design guidelines]. The standard of compatibility can be met through scale, materials, and forms which may be embodied in architecture which is contemporary as well as traditional. The replication of important historic sites in Albemarle County is not the objective of these guidelines. 10 Buildings should relate to their site and the surrounding context of Several buildings are proposed, but Provide material/color buildings. no physical connecting devices are used. The applicant's narrative samples for review. 12 Architecture proposed within the Entrance Corridor should use forms, shapes, scale, and materials to create a cohesive whole. suggests that all the buildings in the development will have a coordinated 14 Arcades, colonnades, or other architectural connecting devices should be used to unify groups of buildings within a development. appearance. As the first building to be constructed, the materials, colors and details of the storage building will set the tone for the overall development. Proposed materials include off-white and beige EIFS, light and dark grey CMU, and white and black brick. Samples have not been provided. 1 I The overall design of buildings should have human scale. Scale should be The building measures 230' long and None. integral to the building and site design. 90' wide and is approximately 42' tall. The brick base, awnings, and storefronts at both ends of the building help establish an appropriate scale. 13 Any appearance of "blankness" resulting from building design should be Much of the wall area is without None. relieved using design detail or vegetation, or both. windows, but blankness doesn't predominate due to the distribution of materials and colors, and the scoring of the EIFS panels. 15 Trademark buildings and related features should be modified to meet the The building does not appear to be a None. requirements of the Guidelines. trademark design. 16 Window glass in the Entrance Corridors should not be highly tinted or highly Some of the windows are proposed Eliminate the film coating reflective. Window glass in the Entrance Corridors should meet the with a vinyl film covering to hide the from the windows. following criteria: Visible light transmittance (VLT) shall not drop below storage units. The applicant offers, as 40%. Visible light reflectance (VLR) shall not exceed 30%. Specifications an alternative, replacing the windows on the proposed window glass should be submitted with the application for with additional EIFS panels in a gray final review. color. The gray EIFS panels are not a successful solution. Clear glass without a film coating is appropriate for the ECs. Accessory structures and equipment 17 Accessory structures and equipment should be integrated into the overall Dumpster locations appear to be Provide additional plan of development and shall, to the extent possible, be compatible with appropriate for the EC. The information to show that the building designs used on the site. architectural drawings show a 3'-tall parapet to be used for screening the 3'-tall parapet is sufficient to screen 18 The following should be located to eliminate visibility from the Entrance Corridor street. If, after appropriate siting, these features will still have a rooftop equipment. The equipment is rooftop equipment. negative visual impact on the Entrance Corridor street, screening should be not shown on the drawings; provided to eliminate visibility. a. Loading areas, b. Service areas, c. Refuse equipment often exceeds 3' in areas, d. Storage areas, e. Mechanical equipment, f. Above -ground utilities, height. and g. Chain link fence, barbed wire, razor wire, and similar security fencing devices. 19 Screening devices should be compatible with the design of the buildings and surrounding natural vegetation and may consist of. a. Walls, b. Plantings, and c. Fencing. 20 Surface runoff structures and detention ponds should be designed to fit into Stormwater features are proposed None. the natural topography to avoid the need for screening. When visible from the underground. Entrance Corridor street, these features must be fully integrated into the landscape. They should not have the appearance of engineered features. 21 The following note should be added to the site plan and the architectural plan: The note appears on the site plan, but Add the standard "Visibility of all mechanical equipment from the Entrance Corridor shall be not on the architectural plans. equipment visibility note eliminated." to the architectural plans. 22- Lighting Lighting is not included in the initial None at this time. 31 site plan. Landscaping 7 The requirements of the Guidelines regarding landscaping are intended to With near) 800' of frontage on 51 None. reflect the landscaping characteristic of many of the area's significant Street, the row of large shade trees historic sites which is characterized by large shade trees and lawns. along the EC will help establish a Landscaping should promote visual order within the Entrance Corridor and consistent, orderly and harmonious help to integrate buildings into the existing environment of the corridor. appearance along the corridor. 8 Continuity within the Entrance Corridor should be obtained by planting different types of plant materials that share similar characteristics. Such common elements allow for more flexibility in the design of structures because common landscape features will help to harmonize the appearance of development as seen from the street upon which the Corridor is centered. 32 Landscaping along the frontage of Entrance Corridor streets should include Large shade trees 3.5" caliper at Consider installing the the following: planting are shown spaced 35' on EC frontage trees with a. Large shade trees should be planted parallel to the Entrance Corridor center along the EC frontage. the first block that is Street. Such trees should be at least 3% inches caliper (measured 6 inches Smaller ornamental trees are constructed. above the ground) and should be of a plant species common to the area. irregularly interspersed among the Such trees should be located at least every 35 feet on center. shade trees. No conflicting utilities b. Flowering ornamental trees of a species common to the area should be are shown along the frontage. interspersed among the trees required by the preceding paragraph. The Additional trees are also shown ornamental trees need not alternate one for one with the large shade trees. along the parking lot perimeters that They may be planted among the large shade trees in a less regular spacing are adjacent to the EC, and a group pattern. of trees is added at the southeast c. In situations where appropriate, a three or four board fence or low stone comer of the site. Note: the applicant wall, typical of the area, should align the frontage of the Entrance Corridor does not plan to install the EC street. frontage trees with the Block 5 d. An area of sufficient width to accommodate the foregoing plantings and development. fencing should be reserved parallel to the Entrance Corridor street, and exclusive of road right-of-way and utility easements. 33 Landscaping along interior roads: No trees are proposed along Old Provide large trees, 2V2' a. Large trees should be planted parallel to all interior roads. Such trees Lynchburg and Mountainwood caliper at planting, along should be at least 2'/z inches caliper (measured six inches above the groundA Roads. Trees at the required spacing Old Lynchburg, Country and should be of a plant species common to the area. Such trees should be are shown along Rt. 875, but they are Green, and located at least every 40 feet on center. on, or very close to, a water line. Mountainwood Roads, Trees at the required spacing are free of utilities and shown along the internal road in the easements. eastern half of the development, but many of these are too close to storm pipes. 34 Landscaping along interior pedestrian ways: Trees are provided along all Where large shade trees a. Medium trees should be planted parallel to all interior pedestrian ways. sidewalks in the eastern half of the are not already provided Such trees should be at least 2% inches caliper (measured six inches above development, except along Old to meet other the ground) and should be of a species common to the area. Such tree] Lynchburg Road (where large shade requirements, provide should be located at least every 25 feet on center. trees are required). In the eastern half medium trees, 2'/z" of the development, sidewalks align caliper at planting, along the outer perimeters of the parking lot. Where the sidewalks are located all paths and sidewalks. 35 Landscaping of parking areas: Provide large trees, 2 %" a. Large trees should align the perimeter of parking areas, located 40 feet on between the parking and an caliper at planting, 40' on center. Trees should be planted in the interior of parking areas at the rate of apartment building, trees are not center along the perimeter one tree for every 10 parking spaces provided and should be evenly provided. Along some sidewalks of all parking areas. distributed throughout the interior of the parking area. (near the club house, for example) b. Trees required by the preceding paragraph should measure 2% inches there appears to be sufficient space caliper (measured six inches above the ground); should be evenly spaced; for trees, but none are provided. and should be of a species common to the area. Such trees should be planted in planters or medians sufficiently large to maintain the health of In the eastern half of the the tree and shall be protected by curbing. development, trees are provided c. Shrubs should be provided as necessary to minimize the parking area's along most parking lot perimeters; impact on Entrance Corridor streets. Shrubs should measure 24 inches in however, the middle of the northern height. perimeter is without trees and the spacing is too wide at the north end of the eastern perimeter. 36 Landscaping of buildings and other structures: Architectural designs have only been None at this time. a. Trees or other vegetation should be planted along the front of long provided for the storage building at buildings as necessary to soften the appearance of exterior walls. The this time. The need for landscaping spacing, size, and type of such trees or vegetation should be determined by to soften the appearance of exterior the length, height, and blankness of such walls. walls of the office, retail, hotel and b. Shrubs should be used to integrate the site, buildings, and other apartment buildings will be structures; dumpsters, accessory buildings and structures; "drive thru" determined when those designs are windows; service areas; and signs. Shrubs should measure at least 24 inches submitted for review. Note, however, in height. that there is no planting area provided on the east side of the office and storage buildings. A row of trees is provided along the front of the storage building. 37 Plant species: The proposed trees are found on the None. a. Plant species required should be as approved by the Staff based upon but various lists. not limited to the Generic Landscape Plan Recommended Species List and Native Plants or Virginia Landscapes (Appendix D . 38 Plant health: The note appears on the plans. None. The following note should be added to the landscape plan: "All site plantings of trees and shrubs shall be allowed to reach, and be maintained at, mature height; the topping of trees is prohibited. Shrubs and trees shall be pruned minimally and only to support the overall health of theplant." Site Development and layout Development paftern 6 Site development should be sensitive to the existing natural landscape and The proposed development is Note that the retail, office should contribute to the creation of an organized development plan. This arranged over multiple parcels of and hotel buildings will may be accomplished, to the extent practical, by preserving the trees and land and is divided by Old need to have fully rolling terrain typical of the area; planting new trees along streets and Lynchburg Road. The site layout in designed fronts on pedestrian ways and choosing species that reflect native forest elements; both parts of the development is elevations visible from insuring that any grading will blend into the surrounding topography generally organized. Buildings the EC street. thereby creating a continuous landscape; preserving, to the extent practical, located along the Entrance Corridor existing significant river and stream valleys which may be located on the street are oriented parallel to the site and integrating these features into the design of surrounding street. The retail, office and hotel development; and limiting the building mass and height to a scale that does buildings will need to have fully not overpower the natural settings of the site, or the Entrance Corridor. designed fronts on elevations visible from the street, even though parking 39 The relationship of buildings and other structures to the Entrance Corridor street and to other development within the corridor should be as follows: is to the side and/or rear as viewed a. An organized pattern of roads, service lanes, bike paths, and pedestrian from the EC. The site is currently walks should guide the layout of the site. wooded; all trees would be removed b. In general, buildings fronting the Entrance Corridor street should be from the site to accommodate the parallel to the street. Building groupings should be arranged to parallel the proposed development. The rolling Entrance Corridor street. terrain will not be preserved, but the c. Provisions should be made for connections to adjacent pedestrian and Block 5 building (and possibly vehicular circulation systems. others) will take advantage of the d. Open spaces should be tied into surrounding areas to provide continuity change in grade to reduce the within the Entrance Corridor. perceived scale of the structure. e. If significant natural features exist on the site (including creek valleys, Trees are proposed along the EC and steep slopes, significant trees or rock outcroppings), to the extent practical, internal streets. Sidewalks are then such natural features should be reflected in the site layout. If the proposed within the development provisions of Section 32.5.2.n of the Albemarle County Zoning Ordinance and they connect to sidewalks along apply, then improvements required by that section should be located so as the nearby streets. A dog park is to maximize the use of existing features in screening such improvements proposed at the north end of the from Entrance Corridor streets. eastern part of the development; f. The placement of structures on the site should respect existing views and there is no adjacent open space vistas on and around the site. available for connection. Site Grading 40 Site grading should maintain the basic relationship of the site to surrounding Retaining walls are proposed in the Integrate retaining walls conditions by limiting the use of retaining walls and by shaping the terrain eastern half of the development, with nearby site features. through the use of smooth, rounded land forms that blend with the existing including adjacent to the EC street at terrain. Steep cut or fill sections are generally unacceptable. Proposed contours the proposed office building and on the grading plan shall be rounded with a ten foot minimum radius where park. The topography falls away they meet the adjacent condition. Final grading should achieve a natural, from the EC street, so the height of rather than engineered, appearance. Retaining walls 6 feet in height and taller, the walls won't be visible, but some when necessary, shall be ten -aced and planted to blend with the landscape. of the walls are not integrated with nearby site elements; for example, the wall at the southeast comer of the office building. 41 No grading, trenching, or tunneling should occur within the drip line of any No trees are proposed to be retained. None. trees or other existing features designated for preservation in the final Certificate of Appropriateness. Adequate tree protection fencing should be shown on, and coordinated throughout, the grading, landscaping and erosion and sediment control plans. 42 Areas designated for preservation in the final Certificate of Appropriateness should be clearly delineated and protected on the site prior to any grading activity on the site. This protection should remain in place until completion of the development of the site. 43 Preservation areas should be protected from storage or movement of heavy equipment within this area. 44 Natural drainage patterns (or to the extent required, new drainage patterns) The utility plans show new None. should be incorporated into the finished site to the extent possible. stormwater pipes connecting to existing systems just east and west of the development. ATTACHMENTS A — ABC Initial Site Plan B — ABC Partial Revised Site Plan C — ABC Block 5 Storage Building Preliminary Architectural Plan SUMMARY OF RECOMMENDATIONS Staff recommends the following as the primary points of discussion: 1. The overall site layout. 2. EC frontage trees: timing of planting 3. The architectural design of the storage building: proposed building materials, windows and applied film, the techniques used to break up the length/mass of the building; overall organization. Staff recommends that the ARB forward the following recommendations to the Agent for the Site Review Committee: • Regarding requirements to satisfy the design guidelines as per § 18-30.6.4c(2), (3) and (5) and recommended conditions of initial plan approval: 1. Prior to Initial Plan approval the following items shall be resolved to the satisfaction of the ARB: None. • The ARB recommends approval of the Initial Plan without conditions. • Regarding recommendations on the plan as it relates to the guidelines: 1. Consider installing the EC frontage trees with the first block that is constructed. • Regarding conditions to be satisfied prior to issuance of a grading permit: None. • Regarding the final site plan submittal: A Certificate of Appropriateness is required prior to final site plan approval. The following items and all items on the ARB Final Site Plan Checklist must be addressed: 1. Revise the storage building design to provide greater organization and unity among the various building elements. 2. Provide material/color samples for review. 3. Eliminate the film coating from the windows. 4. Provide additional information to show that the 3'-tall parapet is sufficient to screen rooftop equipment. 5. Add the standard equipment visibility note to the architectural plans: Visibility of all mechanical equipment from the Entrance Corridor shall be eliminated. 6. Consider installing the EC frontage trees with the first block that is constructed. 7. Provide large trees, 2%z" caliper at planting, along Old Lynchburg, Country Green and Mountainwood Roads, free of utilities and easements. 8. Where large shade trees are not already provided to meet other requirements, provide medium trees, 2%" caliper at planting, along all paths and sidewalks. 9. Provide large trees, 2 %" caliper at planting, 40' on center along the perimeter of all parking areas. 10. Note that the retail, office and hotel buildings will need to have fully designed fronts on elevations visible from the EC street. 11. Integrate retaining walls with nearby site features. O ° Q' ^O Ar 6Q 76-46Ae1Qa v 780 D IF / •'� .76-54A1 ) c �/V rv1 16p��o/ 76-46F ;�eMountal�W � ✓ ° - / w ��J � 76-ascf' °dRd 0 Wahoo W`7aV 76'72 76-46A �SA•' 6-54 1211q y IT/ J z a Cf CWII N,-saP1 a / LJJ �76!46H .ountry-Green-Rd e76 a8311 f,� 76-54N1 ° 76-54P Registrar•:. 76-52Lf -44�, O r�pffie6-54Z,� 76-53� C Ln o ' e n �n !V ?j876-!may 76-54WIe-� 76-52L �„ 54H .'^r 76- 53A - yY- 76-5 ,p q O1 in 76+5 7653 .-4 f r 877 76-53B 76-56B „ ❑ 376 i[ _ 76-53A2 J ! ^ 76-53G 76-53G1 76-56D s.J, 76-53F 76.53E A76-53K _ 7 J53P J � /76-53J /sS\ 90A-2 Figure 1: Project location and surroundings. 10 TABLE A This report is based on the following submittal items: Sheet # Drawing Name Drawing Date/Bevision Date INITIAL SITE PLAN Cl Cover 10-5-2020 C2 Existing Conditions: Overview C3 Existing Conditions C4 Existing Conditions C5 Site Plan C6 Site Plan C7 Site Plan C8 Grading & Utility Plan C9 Grading & Utility Plan C10 Landscape Plan Cl1 Landscape Plan C12 Landscape Plan C13 Landscape Details PARTIAL UPDATED SITE PLAN Cl OF 2 Revisions to Initial Site Plan Submission 10-8-2020 10-26-2020 C2 OF 2 Revisions to Initial Site Plan Submission 10-8-2020 ARCHITECTURAL PLANS 1 Cover 10-26-2020 2 Narrative 3 Site Plan Block 5 4 Existing Site Conditions vs New Development 5 Exterior Elevations and Finish Materials 6 Exterior Elevations 7 Exterior Elevations — Alternative Option 8 Schematic Floor Plans I