HomeMy WebLinkAboutSDP202000062 Correspondence Minor Amendment 2020-12-11OLINEAGE ARCIII'1'ECTS • ENGINEERS • SURVEYORS Tori Kanellopoulos, AICP Senior Planner County of Albemarle December 10, 2020 Re: DS Tavern Minor Site Plan Amendment Tori, VDOT comments dated November 23, 2020 stated no comment. We understand that a VDOT Land Use Permit would be required prior to any work within the right-of-way. VHD comments dated November 8, 2020 stated no comment. We understand that the septic system should be assessed by a professional engineer or other licensed consultant to ensure the system has adequate capacity for the proposed site staff and potential clientele. ARB stated no objection per the memorandum dated 08-18-20. We are in receipt of comments regarding SDP202000062, DS Tavern Minor Amendment dated 08-18-20. Planning comments dated 08-18-20 are listed below with our responses in bold. 1. 18-4.1(b) and 18-32.7.5.1(c) Water supplies and sewer systems: health Department approval for the proposed development is required. Understood. 2. 18-4.2 Critical Slopes. a. Label all 'steep slopes' as 'critical steep slopes'. Labels have been changed on each sheet to state 'critical steep slopes'. b. Critical slopes must be shown and labeled on all plan sheets. Understood. All plan sheets have been updated to show critical slopes. c. 18-4.2.3(b) Any proposed grading must be shown. Any disturbance of critical slopes requires a special exception and Board of Supervisors approval. Understood. All proposed grading is shown on sheet C-05. No disturbance will occur on critical slopes. 3. 18-21.7 and 18-4.20 Commercial districts — buffer requirement. The site plan shows parking approximately 12 feet from the adjacent property, TMP 59-16A, which is zoned Rural Area. 18- 21.7 requires a 20-foot undisturbed buffer for commercial uses adjacent to residential and rural areas. The parking on preapplication plan SDP201900076 appeared to meet this requirement, however the parking shown on this site plan does not appear to. Either the parking must be revised to be at least 20 feet from the property, or a special exception must be requested. P.O. 13ox 991 • 98 I,ce Highway • Verona, Virginia 24482 Phone: 540.248.5771 • Fax: 540.248.1628 info@lineagcarch.com A special exception requires approval from the Board of Supervisors. The parking layout has been updated so that all parking is now 20 feet from the property line. That change is reflected on sheets C-04, C-04A, C-0413, C-05. 4. 18-4.20 Setbacks. Remove the 50' side yard setback on the plan sheets on the east side adjacent to TMP 59-15A1— this parcel is zoned C-1 and therefore the 50' setback does not apply. The 50' side yard setback has been removed from the site adjacent to TMP 59-15A1. The change is reflected on sheets C-03, C-03A, and C-04. 5. 18-4.12.13 Loading space. The ordinance requires one loading space for office uses under 8,000 square feet. This requirement may be waived per 18-4.12.13(f). Provide a loading space meeting the dimension requirements of 18-4.12.18 or provide a justification as to why a loading space is not needed. We acknowledge and understand the requirement of ordinance 18-4.12.13(c), but we feel that the low level of on -site staff as well as the intended use of the office as a space for managing local assets will not generate the size or quantity of deliveries to the building such that a loading space would be necessary. These facts, in combination with the owner's intention to maintain the historic character of the site, lead us to believe that the loading space requirement should be waived via 18-4.12.13(f). This description of intent can be found at General Note 12 on sheet C-04. 6. 18-32.5.2 Contents of an initial site plan and 18-32.6.2 Contents of a final site plan: a. Topography/applicable sheets: i. Existing topography and any proposed grading need to be shown on site plan sheets. Existing topography is shown on sheets C-03 and C-05. All proposed grading is shown on sheet C-05. Topography and grading are confined to those sheets to preserve legibility of critical information on other sheets. ii. Show critical slopes on all plan sheets as well to determine if any grading is disturbing critical slopes. Critical slopes layer has been added to sheet C-05. No grading shall occur in any area designated as critical slopes. b. Work appears to be shown on the adjacent property TMP 59-15A1, including plantings. Include ownership information for this parcel on sheet 1. TMP 59-15A1 is owned in conjunction with TMP 59-15A. Ownership information has been added to sheet C-01. Parcel -specific ownership information is shown on sheet C-03. c. Sheet 1: i. Revise title to "SDP202000062 Minor Amendment: DS Tavern". Requested change has been made to sheet C-01. ii. Include the owner of the property on sheet 1: Ivy Road RE LLC. Change has been made. iii. Include the tax map parcel on sheet 1: 059000000015A0. Change has been made. iv. Include the proposed use development. E.g. 'building addition for X square feet of office space. X additional parking spaces, etc.'. Change has been made. v. Rename 'Geometry of Zone C-1' to 'Setbacks and Building Height C-1 Commercial Zoning District'. Change has been made. P.O. I3ox 991 • 98 I.ee IIighway • Verona, Virginia 24482 Phone: 540.248.3771 • Fax: 540.148.1618 intb@lineageaj-cli.com vi. Include the zoning of the property on sheet 1. All zoning information requested has been added to sheet C-01. vii. Include the magisterial district of the property: Samuel Miller District. Change has been made. viii. Include that the property is located in the South Fork Rivanna Water Supply Watershed. Change has been made. ix. Include a note that the property is not within the ACSA jurisdictional area and does not have access to public water/sewer. Note has been added to sheet C- ol. x. Include one datum reference for elevation. Datum reference has been added to sheet C-01. d. Sheet 3: I. Revise Note 4 — property is split zoned C-1 and RA. Note has been amended on sheet C-03. ii. The zoning district of adjacent properties has not been included. Revise to the following:... Requested revisions to zoning districts of adjacent properties have been made on sheet C-03. iii. The zoning district and ownership information for TMP 59-15A1 must also be included on this sheet. Understood. Requested information for TMP 59-15A1 has been added to sheet C-03. e. Sheet 4: i. Remove Note 12 from sheet 4. Indicated note has been removed from sheet C- 04. ii. Remove note on sheet 4: 'Net Plans approved by Kristopher Taggart May 22, 2020'. Indicated note has been removed from sheet C-04. f. Show/label Route 250 ROW on applicable sheets. Route 250 ROW is now shown and labeled on sheets C-03, C-03 A, C-04, and C-05. g. More clearly show any existing known easements and their dimensions, and show them on applicable sheets, such as the shared driveway access easement. Sheet C-03 A has been added to the set to increase legibility of all existing easements, buffers, etc. The shared access easement is shown on both sheet C-03 A, and sheet C-04. All existing easements are dimensioned on sheet C-03 A. In. With resubmittals, continue to update revision dates. Understood. i. Include the full following requirement: The location of existing and proposed ingress to and egress from the site, showing the distance to the centerline of the nearest existing street intersection. Location of existing point of site ingress and egress is shown on sheet C-03. No change in the point of ingress and egress is proposed. As such, the "proposed" point of ingress and egress is shown on sheet C-04 at the same location as the existing point of ingress and egress. The nearest existing public street intersection is Bloomfield Road approximately 1,553'to the west. This information is also shown on sheet C-03. P.O. Box 991 • 98 Lee Highway • Verona, Virginia 24482 Phone: 540.245.3771 • Fax: 540.248.1628 info@Iineagearch.com 7. 18-32.7.9.4 Landscape plan/preservation of existing trees. Include the signed Conservation Checklist with the landscape plan. Understood. 8. Chapter 17 WPO/VSMP. Based on Engineering review, it appears land disturbance is less than 10,000 square feet; therefore, a WPO/VSMP application does not appear to be needed. If land disturbance is greater than 10,000 square feet, please note that a WPO/VSMP will be required and must be approved prior to site plan approval. Understood. Engineering comments dated October 9, 2020 are listed below with our responses in bold. 1. C-01 Revise plan title to include SDP202000062. Title has been revised per recommendations. b. Note that begins 'Jon Garber is the Certified Land Disturber' should be deleted. Indicated note has been deleted. c. Tier III Groundwater Assessment report has been submitted and is under review by Engineering. GWA report must be approved prior to Minor Site Plan Amendment approval. Understood. 2. Note: C-05 A: E&SC Narrative,... Comments concerning current LOD estimate, increase in LOD, and requirements should the threshold of 10,000 square feet be crossed have been noted and taken under consideration. 3. At 0.19 Ac. LOD, VESCP/VSMP program and stream buffer avoidance/mitigation requirements do not apply. Engineering recommends text at item 2. Above be copied verbatim to Minor Amendment title sheet. Text from item 2. Has been copied to sheet C-01 per Engineering's recommendation. 4. A slight increase in land disturbance is possible without exceeding 10,000 sq.ft. Noted. Due to necessary revisions to parking area, land disturbances now total 9,827.7 sq. ft — 0.22 ac. E&SC narrative on sheet C-05 A has been updated to reflect the higher amount of disturbance. 5. Note: Should stream buffer requirements apply to a revised submittal,... Comments concerning the application of stream buffer, VESCP/VSMP requirements to current design versus how the same requirements may be affect a design revised for resubmittal are understood and have been taken into consideration. No revisions have been made that increase the LOD beyond the 10,000 sq.ft. threshold, nor have any revisions been made that place proposed design elements within So' of the stream centerline. 6. Note: Applicant may remove reference to ESC plan, narrative, VESCH detail / E&SC plan legend, Certified Land Disturber, etc. provided final design = area of Land disturbance is less than 10,000 scift Understood. 7. If Minor Amendment (MIA) retains ESC measures, narrative, details, etc., these elements may become binding with the approved site plan amendment. While Engineering encourages silt fence, ordinance does not mandate any VESCP measures for this project in proposed design configuration with LOD =0.19 Ac. Understood. Engineer of record agrees with use of silt fence on a project regardless of scale and as such silt fence has been retained. P.O. Box 991 • 98 Lcc Highway • Verona, Virginia 24485 Phonc: 540.24,8.3771 • Fax: 540.248.1628 info@lincagcarch.com O 8. MIA should retain all reference labels and linework that show/indicate stream buffer on parcel/s under development. With slight increase in estimated LOD, stream buffer requirements may apply. Understood. 9. C-03: Reatin line -type reference to critical slopes, and please revise steep slope overlay label/s to read critical slopes. Critical slope overlay has been retained on/added to all plan sheets. Label has been revised to read 'critical steep slopes' per this comment and similar comment from Planning. 10. 18-4.2, Critical slopes, requirements apply to design. a. 18-4.2.3 explains improvements shown on a site plan shall not be located on critical slopes. Understood. No proposed development occurs on critical slopes. b. C-03 shows a proposed stone retaining wall on critical slopes. To clarify, sheet C-03 is a record of existing site conditions only. The stone retaining wall already exists on the site. Also, said stone retaining wall defines the downslope edge of the critical slopes overlay, but is not itself located within the overlay. c. Coordinate critical slope modification or waiver with Site Plan review coordinator. Per response to 30.(a) /10.(b), neither modification nor waiver is needed. No action was taken. 11. US Rt. 250 right-of-way (ROW) a. Label ROW (linework) across parcels under development. VDOT ROW' label has been added to linework at indicated location on sheets C-03, C-03 A, C-04, C-04 B, and C-05. b. Note: A VDOT Land Use permit is required for work within public right-of-way. No work is proposed with the ROW. This requirement has been made clear to General Contractor. c. VDOT must approve entrance geometry and improvements within public right-of-way. Understood. d. C-03: Transfer sight distance lines that overlay photo to graphic portion of ex. conditions sheet. Sight distance inset has been removed from sheet C-03 and sight distance lines have been transferred to main existing conditions plan as requested. e. Provide (vertical) sight distance profile at Ivy Road to ensure adequate vertical sight distance at site entrance, for drivers entering onto Rt. 250. Profile has been added. See 'Sight Distance Profile at Ivy Road', sheet C-03. 12. C-03 a. Revise contour labels consistent with actual elevations. Understood. Existing contour labels on sheet C-03 and C-05 have been revised to reflect elevations as shown in Albemarle County GIS. b. General Note 6: Provide date of 'current field survey.' FSP checklist for plan reviewers requires topography be at least visually field verified by the designer within the last year. Indicated note has been updated to reference C-03, Note 1: Current field survey recorded by Lineage Architects, PC on Oct. 28, 2019. c. Label TMP 05900-00-00-015A3 if any development is proposed to occur on this parcel, and provide deed bk.-pg. ownership information for this parcel. No development is intended to occur on TMP 59-15A1. However, all ownership info, zoning, etc. for said parcel has been included on C-01 and C-03 per other department comments. P.O. Box 991 • 98 Lee Highway • Verona, Virginia 2,1482 Phone: 540.248.3771 • Pax: 540.248.1628 info@lineagearch.com O 13. C-04 a. Label stone retaining wall, and max. wall height. Change has been made to sheet C-04. b. Retaining wall height>3' requires a building permit, and safety railing. Retaining wall height >4' requires (PE -)sealed geotechnical design. Understood but not applicable to this project. c. Recommend spot elevations on C-04 supplement direction of proposed flow arrows shown on C-05. Noted. d. Label proposed parking area curb radii. Per C-04, Note 1, all parking radii not = 5' have been labeled on C-04. e. Label CG-6 curbing. The proposed design referenced in Minor Amendment 08-18-20 called for CG-2 curbing. However, no curbing has been labeled as the design team has requested that the requirement for curb and gutter as established by 18-4.12.15(g) be waived. Figures for pre -development impervious drive materials have been listed on sheet C-03, and post -development figures have been listed on C-04 for comparison. Each separate surface material has been labeled for further clarification. f. Label walkway widths. All proposed walkway widths have been labeled on sheet C-04. g. Label site entrance width (narrowest point). Site entrance dimensions have been added to sheet C-04. h. Label entrance (curve) radii at intersection with US Rt. 250. Radii have been added to C-04. 14. C-05 a. As noted above, VESCP requirements do not apply but grading needs to be shown with this MIA. Noted. b. Proposed grading on this Grading/E&SC Plan is ambiguous. Conventional heavier or darker linetype is not apparent. Comments on proposed contours are understood. Lineweights / linetypes for proposed grading as shown on sheet C-05 have been updated to add clarity. c. 'Limit of Construction' labels on this sheet do not correspond with distinct LOD line - type. LOD boundary has been update on sheet C-05 to reflect changes to proposed site plan. New LOD boundary has been labeled with 3 distinct 'Limits of Disturbance' leaders to add clarity. d. Provide labels to indicate Limits of Construction = 0.19 Ac. (area of land disturbance) Requested note has been added beneath 'Limits of Disturbance' label at east side of LOD boundary. e. E&SC plan elements (apart from grading), including proposed temporary E&SC perimeter measures (silt fence), seeding schedules, general erosion and sediment control notes, C-05 A text, and C-06 silt fence detail may be removed from Site Plan Amendment, but see item 14.j., below. Noted. Sheet C-05 A has been removed from the MIA. Additionally, seeding schedules and mulching schedules have been removed from sheet C-05. All E&SC measures have been removed from the plan on sheet C-05 apart from necessary tree protection for existing trees to remain and the sections of silt fence deemed useful, in our professional opinion. As such, the silt fence detail remains on sheet C-06. P.O. Box 991 • 98 Lee Highway • Verona, Virginia 24.4-82 Phone: 54,0.248.3771 • Fax: 540.24.8.1628 info@1ineagearch.com O f. Please delete General Erosion and Sediment Control Note ES-4. This requirement has been noted as "Not Used". g. E&SC Note ES-5 is problematic:... Wording has been altered to trigger upon offsite activities or on -site activities causing a cumulative 10,000 or more square feet disturbance. h. Retain E&SC Note ES-10 as a general note on Minor Site Plan Amendment (MIA). Noted. i. Note ES-13 is a useful reminder. Engineering recommends retain on MIA as a general note. Noted. j. Summary (General E&SC Notes)... Summary of Engineering's recommendations on notes to remain and what additional requirements must be met should the LOD exceed 10,000 sq ft is understood. k. Should LOD increase to >_ 10,000sq ft, a separate WPO Application is required with items listed at 14.e. transferred to a VSMP/WPO plan, which will in turn consider erosion and sediment control and stormwater management requirements, including a SWPPP with pollution prevention plan. Understood. Fire and Rescue comments are listed below with our responses in bold. 1. The travel way appears to exceed 150' without an emergency apparatus turn around. Understood. Per conversation with Tori Kanellopoulos and Shawn Maddox on December 4, 2020, the 'tee' intersection created between proposed gravel parking lot and site entrance on TMP 59-15A, and existing gravel driveway on adjacent parcel TMP 59-15A1 is deemed sufficient to meet the requirement for an emergency apparatus turnaround. 2. Please provide the distance from the parking surface to the far corner of the two-story addition. Any structures constructed must be within 150' where emergency vehicles will park. Understood. Two dashed lines with directional arrows have been added to sheet C-04. Each line is labeled 'Emergency Access' and includes the path distance, rounded up to the nearest foot, from the parking surface to the far corner of the two-story addition. 3. Provide and ISO needed fire flow for the structure. Provide the current fire flow data from the closest ACSA hydrant. The requested information has been listed on sheet C-04 under the heading 'Fire Fighting Information'. 4. A Knox Box will be required. A note indicating the requirement can be added the plan with the location approved by the fire marshal's office. Understood. The indicated note and the proposed location of the Knox Box have been added at the east side of the site entrance on sheet C-04. Inspections comments are listed below with our responses in bold. 1. Show accessible parking and aisle on C-04. Requested changes have been made to sheet C-04. 2. Provide detail of accessible parking and aisle on C-06. Requested detail can be found on sheet C-06 A. A note referencing the location of that specific detail has been added to sheet C-04. 3. Identify accessible route to building from accessible parking space. Aline with directional arrows has been added to the plan on sheet C-04 to designate the accessible path. The line is called out as'ADA Accessible Path'. P.O. Box 991 • 98 Lee Highway • Verona, Virginia 24482 Phone: 540.21.8.3771 • Fax: 540.248.1628 info@lineageai-ch.com 4. Accessibility must be in compliance with the VCC, VEBC, and ANSI A117.1-09. Noted. Thank you for the opportunity to respond to these comments. Please contact our office with any comments or questions. 3deth'an ry res C a er, Principal Engineer Lineage Architects, P.C. Cc: FGS Design, LLC Ralph Harvard, Inc. Monroe -Crocker, PC Michael Morris File JONATHAN F.GARBER No. 038568 AL P.O. Box 991 • 98 Lee Highway • Verona, Virginia 24482 Phone: 540.248.3771 • Fax: 540.248.1628 info@lineagearch.com