HomeMy WebLinkAboutARB202000126 Certificate of Appropriateness 2020-12-15COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902-4596 Phone (434) 296-5832 Fax (434) 972-4126 December 15, 2020 Peter Gropper Atlantic Coast Signs PO Box 243 Ruckersville, VA 22942 RE: ARB-2020-126: Auto Zone Signs (061WOO10A00300) Dear Applicant, We have reviewed your request for the above -noted signs and have approved the designs for the Architectural Review Board as illustrated in the attached drawings. Note that the approved channel letter sign drawings are noted as "CUSTOM". You may consider this letter your Certificate of Appropriateness. This approval is specifically conditioned on the following: 1. Execution of the design indicated on the final approved plans, attachments, materials, samples, and other submittal items presented. 2. The approved orange color is Pantone 1585C and the approved red color is Pantone 187C. 3. The backgrounds of the freestanding sign panels must be opaque. Please note the following: 1. Zoning, building, and other approvals may still be pending for your sign permit. This approval is only for the Architectural Review Board/Entrance Corridor. 2. This ARB approval is only one approval required prior to installing a sign. An approved sign permit is also required. DO NOT proceed with the construction or installation of your sign until you have received your signed permit. If you have questions about the status of a sign permit application, please contact the permit intake staff at 296-5832. 3. Any changes in the approved design will require a new application and additional review. 4. "Opaque" means that light will not pass through the material. Consequently, the color of the background portion of the face of the sign will not be visible when the sign is internally illuminated at night. If you have any question about this requirement for an opaque background, do not proceed with the construction or installation of the sign until you have spoken with County staff. If you have any questions concerning this action, please feel free to contact me. Sincerely, Margaret Maliszewski Planning Manager 434-296-5832 x3276 mmaliszewski@albemarle.org ....................... IIIIII1111MI IYII IIIIIIIIIIIIIII IIIIIIIIIIIIIII -- ---- MM _- == = ==E= I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I Y 11111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111 �........................1 �.... - ..................... _ E •E .......................... "iii" nmmnnmm�nnnnnnnnmmmm MM mmnmm�m 34LS CUSTOM FACE LIT CHANNEL LETTERS w/ STRIPES (Qty 1) AZ1CL34-371-5LINT SQUARE FOOTAGE: 87.5 AZ1CL34-371-5LEXT 30'-10 7/8" 8'-0" 17'-1 3/8" N vo o e FRONT VIEW SCALE: 1/4"=1'-0" LED LAYOUT SCALE:NTS SPECIFICATIONS 1. 3/16"THK WHITE PLEXIGLAS w/ DIGITALLY PRINTED TRANSLUCENT VINYL APPLIED FIRST SURFACE DP-2 AUTOZONE LETTERS 2. AUTOZONE LETTERS INTERNALLY ILLUMINATED w/ GE TETRA LED 3. 3/16" THK WHITE PLEXIGLAS w/ DIGITALLY PRINTED TRANSLUCENT VINYL APPLIED FIRST SURFACE DP-1 AUTOZONE STRIPES 4. AUTOZONE STRIPES INTERNALLY ILLUMINATED w/ GE TETRA LED 5. 5" PRE -FINISHED .040 BLACKANHITE ALUMINUM RETURNS LETTER LOCKED & RIVETED TO BACK AND CAULKED / INSIDE OF LETTERS AND STRIPES TO BE WHITE 6. 1" GLOSS BLACK JEWELITE TRIM FASTENED TO LETTERS & STRIPES w/ MINIMUM #8 SHEET METAL SCREWS PAINTED P-8 / SPACING SHALL NOT EXCEED 18" / NO FEWER THAN FOUR (4) SCREWS PER FACE 7. WHITEIWHITE ACM BACKS LETTER LOCKED & RIVETED TO RETURN AND CAULKED 8. WHITE ALUMINUM TAB w/ 0 DIGITALLY PRINTED VINYL APPLIED FIRST SURFACE DP-2 9. AUTOZONE REQUIRED MOUNTING HARDWARE: TOGGLE BOLTS -Ell WALLS OR MASONRY LAGS-CMU/MASONRY WALLS / INSTALLER TO PROVIDE HARDWARE (REFER TO WALL SYSTEMS w/APPROVED FASTENERS CHART) COLORSIFINISHES 10. 1/2" FLEXIBLE CONDUIT/ GREEN FIELD 0 P-7 SW 6091 RELIABLE WHITE 11. 1/4" DIA WEEP HOLES P-8 GLOSS BLACK 12. 120V-20 AMP PRIMARY ELECTRICAL CONNECTIONS /TO BE MADE BY LICENSED 0 DP-1 PMS 1585C ELECTRICAL CONTRACTORS 13. UL APPROVED ELECTRICAL SHUT OFF SWITCH DP-2 PMS 187C 14. TETRA POWER SUPPLY MOUNTED TO BOTTOM OF TRANSFORMER BOX 15. INTERIOR RACEWAY AS NEEDED: 4" x 5"H x.063 WHTIWHT ALUMINUM BREAKFORMED INTERIOR TRANSFORMER BOX w/ REMOVABLE FACE / PAINTED P-7 NOTES -ALL VISIBLE SCREW HEADS & POP RIVETS PAINTED P-8 5' 2" GAP IN BACK PANEL TO ALLOW ACCESS TO ELECTRICAL WHIPS 15 NIGHT VIEW SCALE:NTS .. 12 `1 4' 13 OC I0�' U I' IMOR 14 N sale 9 MUM 30111 THIS SIGN IS INTENDED TO BE INSTALLED FASCIA SECTION DETAIL SCALE: NTS OF ARTICLE 600 OF THE NATIONAL ELECTRIC CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. WALLSYSTEMS APPROVED FASTENER 318 THREADED ROD I HRU•BOLT WOOD, CONCRETE BLOCK OR EIFS wl NUT & WASHER 318" THREADED ROD THRU•BOLT wI I METAL OR EIFS TOGGLEANCHOR CONCRETE, MASONRYAND BRICK ��dr,,p1 318"CIA. LAG wl 318"SHIELD &WASHER .:,�.�y • EMBED A MINIMUM OF 3" 111tR$ 318' CIA RED HEAD LARGE DIAMETER TILT -UP CMU -EMBED A MINIMUM OF 3" TAPCON FASTENER 'FOR ALL OTHER WALL CONDRIONS NOT LISTED ON THIS APPROVED FASTENER SCHEDULE, INSTALLER IS TO DETERMINE A SUITABLE METHOD OF ATTACHMENT FOR SIGNAGE AND OBTAIN APPROVAL FROM JONES SIGN. IF INSTALLER IS UNSURE OF A METHOD, JONES SIGN MUST BE CONSULTED. FOR ALLATTACHMENT METHODS, INSTALLER MUST ADHERE TO GUIDELINES ON USE AND SITE PREPARATION RECOMMENDED BY FASTENER MANUFACTURER JONES SIGN Your Vision. Accomplished. WWW.JONESSIGN.COM J013#231685-114 DATE: 12.28.2018 DESIGNER: Jenee Sotka SALES REP: Mike Bjorklund PROJ I Sand Mansfield Y REV I DATE I BY DESCRIPTION CLIENTAPPROVAL DATE `` 1® �iO■O Site#6464 CHARLOTTESVILLE, VA SHEET NUMBER , 01.11,9 ,5 REVISED TO WET SO Fr REQUIREMENTS 3 °"°'° TS UEDATE RED&Ol C 3 03.0I30 i5 REDAIE REDION 1MM MENT TO RA$GNLWIS PER Cry /ODC Ii'1563i'RSLETTERSETS / REMOVE aPTlox i MCNUMEfIT 4 M= JB �^��TO� s 99.99m nc 6 00.00m ne xxne S 9a99m ne ncec e °B.°Bm nc ncxx LANDLORD APPROVAL DATE OC SIGN PHASE: CONCEPTUAL This is an original, unpublished drawing by Jones Sign Co., Inc. It is for your personal use in conjunction with a project being planned for you by JONES SIGN. It is not to be shown to anyone outside of your organization, nor is it to be used, reproduced, copied or exhibited in any fashion. Use of this design or the salient elements of this design in any sign done by any other company, without the express written permission of JONES SIGN, is forbidden by law and carries a civil forfeiture of up to 25%of the purchase price of the sign. JON ES SIGN will endeavor to closely match colors, including PMS, where specified. We cannot guarantee exact matches due to varying compatibility of surface materials and paints used. All sizes and dimensions are illustrated for client's conception of project and are not to be understood as being exact size or exact scale. 34NS CUSTOM FACE LIT CHANNEL LETTERS w/o STRIPES (Qty 1) AZ1CL34-205-5LINT SQUARE FOOTAGE: 48.5 AZ1 CL34-205-5LEXT 17'-1 3/8" N vo o e FRONT VIEW SCALE: IIC=1'-0" LED LAYOUT SCALE: NTS SPECIFICATIONS 1. 3/16" THK WHITE PLEXIGLAS w/ DIGITALLY PRINTED TRANSLUCENT VINYL APPLIED FIRST SURFACE DP-2 AUTOZONE LETTERS 2. AUTOZONE LETTERS INTERNALLY ILLUMINATED w/ GE TETRA LED 3. 5" PRE -FINISHED .040 BLACKANHITE ALUMINUM RETURNS LETTER LOCKED & RIVETED TO BACK AND CAULKED / INSIDE OF LETTERS AND STRIPES TO BE WHITE 4. 1" GLOSS BLACK JEWELITE TRIM FASTENED TO LETTERS & STRIPES w/ MINIMUM #8 SHEET METAL SCREWS PAINTED P-8 / SPACING SHALL NOT EXCEED 18" / NO FEWER THAN FOUR (4) SCREWS PER FACE 5. WHITE(WHITE ACM BACKS LETTER LOCKED & RIVETED TO RETURN AND CAULKED 6. WHITE ALUMINUM TAB w/ 0 DIGITALLY PRINTED VINYL APPLIED FIRST SURFACE DP-2 7. AUTOZONE REQUIRED MOUNTING HARDWARE: TOGGLE BOLTS-EIFS WALLS OR MASONRY LAGS-CMU/MASONRY WALLS / INSTALLER TO PROVIDE HARDWARE (REFER TO WALL SYSTEMS w/APPROVED FASTENERS CHART) 8. 112" FLEXIBLE CONDUIT/ GREEN FIELD 9. 114" DIA WEEP HOLES COLORSIFINISHES 10. 120V-20 AMP PRIMARY ELECTRICAL CONNECTIONS /TO BE MADE BY LICENSED 0 P-7 SW 6091 RELIABLE WHITE ELECTRICAL CONTRACTORS P-8 GLOSS BLACK 11. UL APPROVED ELECTRICAL SHUT OFF SWITCH DP-2 PMS 187C 12. TETRA POWER SUPPLY MOUNTED TO BOTTOM OF TRANSFORMER BOX 13. INTERIOR RACEWAY AS NEEDED: 4" x 5"H x .063 WHTIWHT ALUMINUM BREAKFORMED INTERIOR TRANSFORMER BOX w/ REMOVABLE FACE / PAINTED P-7 NOTES -ALL VISIBLE SCREW HEADS & POP RIVETS PAINTED P-8 5' MATERIAL LIST MATERIAL BREAKDOWN LED GEMXRD-W1 Modules 12V P/S Module GEMXRD-W1 121 Mod 61 Ft A 19.0 1 U 13.0 Power GEPS12-60U-NA 2 Ea T 10.0 Supply 0 14.0 1 Supply Wire 9409 125 Ft Z 21.0 Choose one wire 192160004 42 Ea O 14.0 connector 191600041 42 Ea N 14.0 End Caps 191600041 38 Ea E 16.0 2" GAP IN BACK PANEL TO ALLOW ACCESS TO ELECTRICAL WHIPS 13 NIGHT VIEW SCALE: NTS .. 10 `1 i 4" 11 tUJ 12 M sele 7 MUM 30111 THIS SIGN IS INTENDED TO BE INSTALLED FASCIA SECTION DETAIL SCALE: NTS OF ARTICLE 600 OF THE NATIONAL ELECTRIC CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. WALLSYSTEMS APPROVED FASTENER 318" THREADED ROD THRU-BOLT WOOD, CONCRETE BLOCK OR EIFS wl NUT & WASHER 318" THREADED ROD THRU-BOLT wI METAL OR EIFS TOGGLEANCHOR CONCRETE, MASONRYAND BRICK 318" CIA. LAG Al 318" SHIELD & WASHER • EMBED A MINIMUM OF 3" 3/8' CIA RED HEAD LARGE DIAMETER - -- TILT -UP CMU -EMBED A MINIMUM OF 3" TAPCON FASTENER "FOR ALL OTHER WALL CONDRIONS NOT LISTED ON THISAPPROVED FASTENER SCHEDULE, INSTALLER IS TO DETERMINE A SUITABLE METHOD OF ATTACHMENT FOR SIGNAGE AND OBTAIN APPROVAL FROM JONES SIGN. IF INSTALLER IS UNSURE OF A METHOD, JONES SIGN MUST BE CONSULTED. FOR ALLATTACHMENT METHODS, INSTALLER MUST ADHERE TO GUIDELINES ON USE AND SITE PREPARATION RECOMMENDED BY FASTENER MANUFACTURER JONES SIGN Your Vision. Accomplished. WWW.JONESSIGN.COM J013#231685-114 DATE: 12.28.2018 DESIGNER: Jenee Sotka SALES REP: Mike Bjorklund PROJ MGR: Sand Mansfield y REV I DATE I BY DESCRIPTION CLIENTAPPROVAL DATE `` 1® �iO■O Site#6464 CHARLOTTESVILLE, VA SHEET NUMBER , 01.11,9 ,5 REVISED TO WET SO Fr REQUIREMENTS 3 °"°'° TS UPDATE REDO C 3 03.0I30 i5 REDAIE REDION 1MM MENT TO RA$GNLWIS PER Cry /ODC l4'1563i'RSLETTERSETS / REMOVE aPTlox i MCNUMEfIT 4 020BA is REA��TO� s 99.99m nc 6 00.00m ne xxne a 9o.99m ne ncec e °B.°Bm nc ncxx LANDLORD APPROVAL DATE OC SIGN PHASE: CONCEPTUAL This is an original, unpublished drawing by Jones Sign Co., Inc. It is for your personal use in conjunction with a project being planned for you by JONES SIGN. It is not to be shown to anyone outside of your organization, nor is it to be used, reproduced, copied or exhibited in any fashion. Use of this design or the salient elements of this design in any sign done by any other company, without the express written permission of JONES SIGN, is forbidden by law and carries a civil forfeiture of up to 25%of the purchase price of the sign. JON ES SIGN will endeavor to closely match colors, including PMS, where specified. We cannot guarantee exact matches due to varying compatibility of surface materials and paints used. All sizes and dimensions are illustrated for client's conception of project and are not to be understood as being exact size or exact scale. D/F INTERNALLY LIT MONUMENT (Qty 1) AZ2FS48-96-24L CABINET SQUARE FOOTAGE: 32 BASE SQUARE FOOTAGE: 48 TOTAL SQUARE FOOTAGE: 80 SCALE: 311° SCALE: 311 SPECIFICATIONS 1. FRAMED CABINET W/ PRE -FINISHED BLKANHT ALUMINUM SKIN 2. 1 1/2' PRE -FINISHED BLKANHT ALUMINUM RETAINERS & DIVIDER BAR COLORSIFINISHES 3. WHITE POLYCARBONATE FACES 0 P-1 RUSTOLEUM 20-9109 WHITE PRIMER 4. FIRST SURFACE APPLIED 3M TRANSLUCENT VINYL GRAPHICS V-2 / DIGITALLY PRINTED TRANSLUCENT V-2 3M 3630-22 BLACK OPAQUE VINYL VINYL APPLIED FIRST SURFACE DP-1, I / FIRST SURFACE APPLIED DIE CUT BLOCK OUT VINYL V-0 O V-4 3M 3635-20B WHITE BLOCK OUT VINYL 5. INTERNALLY ILLUMINATED w/ GE LED STICKS 6. STEEL POLE SUPPORT / PORTION INSIDE CABINET PAINTED P-1 (POLE SUPPORT & FOOTING DP-1 PMS 1585C SIZE TO BE DETERMINED PER ENGINEERING DP-2 PMS 187C 7. THIN BRICK VENEER BASE, FIREHOUSE TUMBLED BRICK- ENVIRONMENTAL STONEWORKS/BY OTHERS HIGH I VIPW SCALE:NTS vJ O N ES SIGN Your Vision. Accomplished. WWW.JONESSIGN.COM JOB#:231685-R4 DATE: 12.28.2018 DESIGNER: Jenee Sotka SALES REP: Mike Bjorklund PROJ I Sand Mansfield Y REV I DATE I BY I DESCRIPTION CLIENTAPPROVAL DATE `` 1® �iO -O�J Site #6464 CHARLOTTEBVILLE, VA SHEET NUMBER I� ■O t f af.ff„ ,s R SEDTOWETWIFTWfN1IREMEfDS 3 ""°'° TS Dm WID&ElUD 3 U5. 6. TS DEDATE RUCK OlUJIGE RA$GNLWIS FERCITY /ODD Ii'1563i'RBtET1ER5ET5/ REMOVE OVTION i MONDMEPD 4 M= is E^��TO> s 00.00m nc XXXX 6 ao.'om ax xxxx S nanom xx xxxx e oB.onm xx xxxx LANDLORD APPROVAL DATE QC SIGN PHASE: CONCEPTUAL This is an original, unpublished drawing by Jones Sign Co., Inc. It is for your personal use in conjunction with a project being planned for you by JONES SIGN. It is not to be shown to anyone outside of your organization, nor is it to be used, reproduced, copied or exhibited in any fashion. Use of this design or the salient elements of this design in any sign done by any other company, without the express written permission of JONES SIGN, is forbidden bylaw and carries a civil forfeiture of up to 25%of the purchase price of the sign. JONES SIGN will endeavor to closely match colors, including PMS, where specified. We cannot guarantee exact matches due to varying compatibility of surface materials and paints used. All sizes and dimensions are illustrated for client's conception of project and are not to be understood as being exact size or exact scale. GENERAL NOTES: 1. Do Not Guess. Direct all Questions Concerning This Drawing to Elrod Engineering, LLC.(615-890-9405) 2. Do Not Scale This Drawing. 3. Graphics are not to be Reproduced From This Drawing. 4. Structural Steel Plate & Angle Shall Conform to ASTM A36 (Fy (Yield)= 36 ksi). 5. Steel Pipe Fabricated From Plate Shall Conform to ASTM A36 fFy (YIELD)= 36 ksi min.). 6. Steel Pipe not Fabricated From Plate Shall Conform to ASTM A53 Type "E" or "S". Grade "B" or Equivalent. (Fy (Yield)= 35 ksi min.) Do Not Use Mill Reject Pipe. A53 Type "F" is NOT Permitted. 7. Structural Steel Tubing Shall Conform to ASTM A500 Grade "B" (Fy = 46 ksi). 8. Aluminum Structural Shapes Shall Conform to the Specifications from The Aluminum Association's Aluminum Design Manual 2015 for 6061-T6; Square/Rectangular Tube & Round Pipe (Fy.35ksi Unwelded) Plate and Angle (Fy.35ksi Unwelded) All Structural Shapes (Welded Fy.15ksi S 0.375" Thick, 11ks! > 0.375" Thick) 9. For welding aluminum, Use 5356 alloy electrodes for 6061 Base Metal. 10. "Legible" Mill Test Certificates, Expressed in "KSI" or "PSI", are Required on all Pipe. All Pipe to Conform to ASTM A36 or ASTM A53 Type "E" or "S", Grade "B". The Yield Stress Limits are in Place to Help Ensure the Sign Structure Performs to the Engineered Design. Used Pipe and Pipe for Which Mill will not Provide Certification will not be Allowed! 11. As Pipe Sections are not Perfectly Round, Careful Shop Fit -Up of the Splice Connections Shall be Performed. Line-up Markings are to be Provided to Avoid Costly Labor and Crane Charges. 12. Pipe Shall be Considered Ovalled and Unacceptable if the Measured Outside Diameter at any Point Varies by More Than 2% of the Nominal Outside Diameter as Specified on the Design Documents. Large Diameter Pipes Should be Braced to Help Prevent Distortion After Fabrication. 13. Pipe with Dimpled Walls, Ovalled Pipe and Bent Connection Elements Shall not be Used. 14. Breach Openings of any Size in the Wall of any Pipe Sections are Strictly Prohibited. 15. All Metal not Specified as Aluminum Shall be Steel. 16. Steel Welding to Conform to Recommendations as Published by The American Welding Society 01.1. 17. Aluminum Welding to Conform to Recommendations as Published by The American Welding Society D1.2. 18. Workmen Who will Perform Welding Operations Shall be Certified for the Applicable Welding Procedure. 19. For welding steel, Use E70 Series Low HydrQgen Electrodes, 20. Fabricated Steel Shall be Cleaned of Mill Scale, Oil, & Other Surface Contaminates Prior to Painting. 21. All Steel, Pipe Sections(Exposed and Embedded), and Splice Connections Must be Primed, Painted and Allowed to Cure Prior to Shipping to Site. 22. Alteration to any Fabricated Part of the Structure by Use of a Cutting Torch or any Other Means is Prohibited Without the Consent of the Engineer. 23. The Base Section of Pipe Shall be "Plumb" Before Continuing with the Erection Procedure. 24. Any Holes Cut in Pipe for Handling Must be Completely Filled with Weld Material and Ground Smooth. 25. Cabinet Mounting Bolts to be ASTM F3125 Gr A325. Bolts, Nuts, Flat & Lock Washers to be Zinc Plated or Hot -Dip Galvanized with Threads Excluded From the Shear Plane. Vendor Shall use a Method For Tightening Bolts Such That Proper Pre -load is Obtained as Specified by The American Institute of Steel Construction & The Industrial Fasteners Institute. (J ER14EST ROBERTS ALLEY JR. Lic. No. 04002052279 FOUNDATION NOTES: 1. Concrete shall be Ready Mixed; Designed to develop a minimum compressive strength as stated in foundation criteria below. Water is NOT to be added to concrete at job site. 2. Reinforcing steel shall conform to ASTM A615 Grade 60 w/Deformations conforming to ASTM A-305. 3. Excavation is to be in compliance with OSHA regulations and shall have a level bottom free of loose soil, water and debris. 4. Where Extreme Frost Depth is below bottom of foundation, excavate to 6 inches below frost depth and increase concrete quantity. 5. Bearing Surfaces for foundations should not be disturbed or left exposed during Inclement Weather: Saturation of the on -site soils can cause a loss of strength and increased compressibility. If construction occurs during inclement weather, and placement of the foundation is not possible at time excavated, a layer of lean concrete should be placed on the bearing surface for protection. 6. If rain is expected within 24 hours of completing the concrete pour, the concrete must be covered. If temperatures are expected to drop below 40 degrees within the next 24 hours of completing the concrete pour, then concrete is to be covered and protected to prevent heat loss and freezing. 7. The base of pipe section shall be "Plumb" and "Adequately Braced" to prevent movement before, during, and after concrete pour and left in place until concrete has set. 8. Reinforcing steel shall be free from mud, oil or other nonmetallic coatings that decrease bond. 9. Maintain a minimum of 3" clear distance from face of concrete to all reinforcing steel, unless otherwise noted on drawing. 10. The base pipe is to be protected with an additional asphaltic coating applied to pipe from 6" below top of concrete to 12" above top of finished grade prior to concrete pour. Approved brands of asphaltic coatings are "Gardner Non-Fibered" and "Henry Non-Fibered" asphaltic coating. 11. Bottom reinforcement to be supported w/ concrete block solids no larger than 4"x4". 12. Do not weld reinforcing steel. Reinforcement shall be placed as detailed on the design drawings & "T!ed" securely to prevent movement during concrete pour. 13. Concrete shall not be placed on frozen ground. 14. Do not cold joint concrete. Foundation must be poured continuously until all concrete has been placed. Concrete must be poured as a workable mixture with a Slump between 4"-6". All concrete mixing trucks must thoroughly and completely mix the concrete prior to pouring. 15. Pipe is not required to be filled with concrete. 16. Additional water is not to be added to concrete on site. Additional water decreases the strength of the concrete mixture. Concrete should be rejected in lieu of changing concrete mixture on site. 17. Air Content - Exposure Class F2 & F3: AGGREGATE SIZE 1¢" = 7% AGGREGATE SIZE %" = 6% AGGREGATE SIZE 1" = 6% 18. Vendor should work the top of the concrete to ensure all rock has been covered by cement and top of concrete foundation is level. Top of concrete may be broom finished. 19. Minimum compressive strength of concrete masonry at 28 days as defined in the ACI 530/ASCE 6 Building Code Requirements For Masonry Structures shall be f'm = 1,500 psi. 20. Mortar shall conform to the following types as defined in the above referenced Building Code: Masonry in contact with earth:Type "M" mortar Exterior block walls and bearing walls:Type "M" or "S" mortar. 21. Provide medium -weight ladder -style horizontal joint reinforcement at 16" on center 22. Grout for filling concrete masonry cells shall conform to standard specifications for "Mortar and Grout For Reinforced Masonry", ASTM C-476, and shall have a compressive prism strength (Fm) = 3,000 psi at 28 days. The slump shall be between 9" and 11". Where the minimum dimension of any continuous vertical cell is 3" or less, use fine grout, otherwise use coarse (pea gravel) grout. 23. Mechanical Vibrators Shall be Used to Consolidate Concrete Around Support and/or Reinforcement. 24. Concrete must be allowed to cure for 14 dayl prior to installing remaining stages of structure or sign cabinet(s). 108/2019 POLE, FOOTING, AND MASONRY BASE PROVIDED AND INSTALLED BY THE GC POLE INSIDE CABINET NEEDS TO BE PAINTED PRIMER WHITE. GC TO COMPLETE. GC IS RESPONSIBLE FOR OBTAINING THE PERMIT AND REQUIRED INSPECTIONS FOR THE FOUNDATION AND MASONRY FOR THE SIGN ERNEST ROBERTS ALLEY JR. Lic. No. 0402052279 Q,r c N/l�/ZCSh7 `` 8'-0" STRUCTURE ELEVATION SCALE: )z" = 1'-0" DESIGN CRITERIA Building Code: IBC 2012/ASCE 7-10 Analysis: LRFD—AISC 14th Chanter 16: Section 1609.3.1 Ultimate Wind Speed Vmt = 110 mph Nominal Wind Speed V.w = 85.21 mph Risk Category. I V" = V"it.,0.6 Exposure: C FOUNDATION DESIGN CRITERIA et Sign Co.) Is wr ch shed Grade Cap Top of R 0 0 0 m Sign Company to Use Experienced Excavation Crew to Perform Foundation Excavation. Where Required, Place Electrical Conduit in Foundation Prior to Concrete Pour. 4.50" O.D. Pipe 0.337" Wall Sign Cabinet (Per Jones Sign Co.) Grout Fill All Reinforced Cells #5 Vertical Rebar W/Dowels From Footing to Match ap 18" Grade bar Pipe To Be Held 8— #5 Rebar 9 6" Off Excovation 3'-0" 8'-6' Long ttom Mat Top & Bottom Mat STRUCTURE PROFILE SCALE: V' = 1'-0" This concrete foundation has been designed in accordance with ACI 318-11 Allowable soil bearing pressure = 2,000 psf. Concrete Shall Develop a Minimum Compressive Strength of 2500psi in 28 Days. Verify Site Conditions Prior to Construction ------------------ 14 Steel Angle Cope Leg of & Weld All Around SECTION A SCALE: 11¢" = 1'-0" Cabinet frame per Jones Sign 42"0 A307 Bolts (Typical) RI—n" Steel Angle E t___ _ _____ i SECTION B SCALE: 1X" = 1'-0" Brick Veneer 8" CMU 00 000 OOO 4.50"0 Pipe 0.337" Wall OOO 000 OO NJ OOO VOOO 11 000 OOO 000 000 O O 0 T a 000 000 000 000 000 000 000 000 0 0 000 000 000 SECTION C SCALE: 1" = 1'-0" ERNEST ROBUTS AUr:Y JR. Lic. No. 0402052279 #5 Vertical Rebar W/Dowel from Footing to Match Cabinet frame per Jones Sign Y2"0 A307 Bolts (Typical) Grout Fill All Reinforced Cells 'C,,.