HomeMy WebLinkAboutVA202000001 Action Letter 2020-12-04COUNTY OF ALBEMARLE
Department of Community Development
401 McIntire Road
Charlottesville, Virginia 22902-4579
Phone (434) 296-5832 Fax (434) 972-4126
December 4, 2020
Michael & Michelle Corbett
8979 Dick Woods Road
Afton, VA 22920
RE: Board of Zoning Appeals Action
VA202000001 Corbett Agricultural Barn/Michael & Michelle Corbett (owners)
Tax Map Parcel: 06900-00-00-02000
Dear Mr. & Mrs. Corbett:
At their meeting on December 1, 2020, the Board of Zoning Appeals found that the
variance application met the definition of a variance in the Virginia Code and that the
variance met all of the requirements in the Virginia Code and voted 5-0 to grant
variance application VA202000001 Corbett Agricultural Barn to allow the proposed barn
to be located 36 feet from the right-of-way of Dick Woods Road, a variance of 39 feet,
with the following conditions:
1. The design of the proposed barn must reflect the elevation and footprint
dimensions and the proposed barn location must be in general accord as shown
in Attachments A and B (attached).
2. The proposed barn may not be used as a dwelling unit or a homestay.
If you are aggrieved by this decision, you have the right to appeal it within thirty (30)
days of the date of the decision, in accordance with Section 15.2-2314 of the Code of
Virginia. If you do not file a timely appeal, this decision shall be final and unappealable.
An appeal shall be taken only by filing a petition specifying the grounds on which
aggrieved with the Circuit Court of Albemarle County within the prescribed thirty (30)
days.
If you have any questions, please feel free to contact our office.
Sincerely,
Bart J. Svoboda
Zoning Administrator
Enclosures
VA2020-01
Corbett Agricultural Barn
ATTACHMENTA
Water Protection
Legend
es zoA2
Ordinance Buffer
P
(Note Some Hems on map may not appear In legene)
a
co
cc
m
`
69-19IA2
O
cO
Oriental
ys
■ Water Protection OrdinanceBuffers
O
\
�
Parcellnfo
❑ Parcels
Elevation
V2 Ellegartion Contours
1
— Y2018 Elevatim Contours (100 %)
— Y2018 Elevatim Contours (0 %)
— V2018 Ekvatim Contours (40 %)
— Y2018 Elevatim Contours (20 %)
— Y2018 Elevatim Contours (4 ft)
Zoning Info
Flood Hazand Overay (100 Year Flo
Steep Slopes Overlay
■ Critical Slopes
Steep Slopes - Managed
8979
a
Steep Slopes - Presented
p
69-19A8
y0
8ZOtt
ad
d,Jl
cp
W f ww�
p
DO i~
O do d!
w
P
A.
m
N PI O.
M pow co, ru m Ott .O
1P
�1p,
_
Ml
f
�O
W
O
mTl`el
W
O
p
O�
8
By9 `%6
69-20C f.
r
pH
1
rtr R
f
?
BY\�9��
860 8S6 !'�
m N
O
f .1 8.
y0,
B6 8S. �F
pip
ft
t 896�
680 on
lghg,
is
fr
909
9•
n
9�1. fC
00r f W O,
9
ZOf, f
O
100 ft
r
2 rn<a
M
r• Mr
Op
02 m GI
GeDi se
Gararvicea
Nwr N]9hic
My daterminalion oftopo3rapby or contours, or any depiction of physical Improvements, property lines or boundaries Isforgereral informalion only and shall ml Mused tm Me design, modification or construction of Improvements to real property or for flood plain determination. Noymmig $3020
Map elements may scale larger than GIS data measured in the map or as provided on the data tlownlced page due to the projection used. Map nocturnal : VJGS84 yJab Mercator (Auuliary Sphere) (EPSG 3857)
ATTACHMENT A.
tl 50 100 200 IF = Iron FoOnd This is to certify that on August 13.14 & V.
{�® UP = Utility Pole 2015, I surveyed the property shown on this plat
!F and the title lines and walls of the building
SCALE IN FEET are shown hereon. This property lies in Zone
7( and does not lie n an area designated as
na'i a 100 Year Flood Hazard as shown on Federal
2 �Y Flood Rate Insurance Map No. 51003CO2250,
effective Oate. Feb. 4, 2005
am 2,61,20' ¢ ,�- 1 Survey performed without the benefit
Um S,ys2'A3'. 6"E � i IF } lN` of a title report and may not indicate
ut 1 R x all encumbrances on the property.
CCO
t.._ \�� Petal)p..-
\, CainOwner:
I Kathleen B. PIahanes
This plat was prepared for, I� S3 t 1 urn
Rebecca L. Pocock utility
tilLegal References.
w'ty 1 313.845 P9.294
} t O B A007 Pg.68
02.1383
D.8 1332 PPgg.7 7
{1g5.4457-E 28597' spike } I
Itypical) Property Line Courses:
1 IF I I ) 1) S62'16'04-E 66A2'
f�ARq 2) R-346.70' L-14.99-
j 3) 507.10'05'E 669i'
A 4) 803'4959'E 66.10'
} I I s) 604 I5ro4 E 78.24
6) S02-52.49-E 37852'
T.W 69--1M4 n ` I I 7) R-1083.16' L=65.06'
K19thlea7 A;alxa.2es i 1 ( I e) S00'33.41-V 154A7'
L?B.4007 Pg.68 0nelling is 95' "A 9) R=3097.76' L=75.00'
W t y Rrc rtY L1r�e to) R=1590.02' L�5412'
t f t i 11) S03'43'057E 195.88'
t1� 1
!i
dl}
Irad - a
rr
\ft is- Z f 6 ro~ Sycamore z �1 l
i t '
Pa=120G
5.00 Acres
z Parcel20A2
7.85 Acresra
t'q�'j La
t I
IF I i
IFS85'44'5; "4I 283.83 1 I
I
I� I II
} Ityplcab ]S I I
N82 l g 42 "Y! 3 .35S 1 {
cl
►�L- z PLAT SHOWING
Robert N. Calemap, Jr. l 69 -M PHYSICAL SURVEY OF
L IC. 9..6.1383 Pg.I1B !
t;j2-��7-5 � T M.P. S 69 - 2OA2 & 2OC
4*,o suav0°
ALSO KNOWN AS
RESIDENTIAL WHISTLING HOLLOW
SURVEYING SERVICES 8979 DICK WOOD ROAD
(434) 245-8744 ALBEMARLE COUNTY, VIRGINIA
CHARL)TTESVILLEI"IVIP51NIED AT22903 AUGUST 26, 2015 1'= too-
15-125
ATTACHMENT B
Corbett Barn Variance Application Description
Dear Board of Zoning Appeals,
In December 2019, we purchased Whistlin' Hollow Farm (Parcels 69-20C and 69-20A2)
with plans to rehabilitate and sensibly expand an historic 90 year -old farmhouse and 13-
acre agricultural property. The grounds had previously thrived as a successful family
farm, raising Katandin Sheep, Sebastopol Geese, and Guinea Hens, as well as growing
a variety of fruits and vegetables. Sadly, this farm had not been maintained by the most
recent owners — who neglected the outbuildings, pastures, garden beds — and allowed
their horses to damage a delicate ecological refuge area. Since we purchased the land,
we have actively restored the garden beds, started growing crops for a local CSA
market, established a new flock of chicken layers, and are actively collaborating with the
James River Association on restoring the stream buffer.
We are applying for a variance to the setback requirements on the front boundary to
build an agricultural barn to support our farm operations in the most practical and least
disruptive location on the farm. The barn will allow us to replace several dilapidated
outbuildings, house our farm vehicles (tractor & implements), and provide a space to
process our crops.
The barn — a classic, traditional -looking structure — was intentionally designed to
minimize new land disturbance and fit the existing topography and site features. Our
intention is to be good stewards of the farm and make conscientious choices to restore
the health and productivity of the riparian area, pastures, and garden beds. We hope to
build the current design in the proposed location for the following reasons:
• The barn is designed to minimize additional cut and fill by taking advantage of a
retaining wall recently rebuilt to stabilize the only existing parking area on the
site, which had been severely compromised. When the property was
purchased, the current parking and access area was held up by a pressure
treated beam retaining wall that was failing due to poor DIY construction,
lack of care, and many years of significant water run-off from a neighboring
property. Due to the increasingly heavy rains, it was clear that we would
(1) have no place to park and (2) no means to access our house at grade
without shoring up the parking lot with a concrete replacement wall. Since
this location is also a perfect place for a barn to house farm equipment and
implements, the new retaining wall can also serve as the foundation wall,
supporting access and entry into the barn.
Corbett Barn Variance Application 1 1
ATTACHMENT B
• By taking advantage of already established infrastructure —the driveway,
parking area, and retaining wall — these features don't need to be created or
expanded into productive pasture or the sensitive buffer areas.
• The proposed location minimizes disturbance from construction and long-term
use in the stream protection area. We are working to improve the condition of the
stream buffer for water quality, habitat, and flood mitigation purposes, and we
don't want to offset our progress by converting a section of the stream protection
area to a new building site.
• We are currently in the process of
restoring and expanding the old
farmhouse, which is located just
9.5 feet from the edge of the property
line. The barn, to be located about
50 feet North from the farmhouse, will
be 36 feet from the property line. The
proximity of the original house to the
road makes the barn feel significantly
set back from the road. The barn is
also designed as a Bank Barn to drop
the building profile and tuck it into the
hillside to minimize visual impact from
the road, and to match the grade of the
parking lot, which is already 8 feet
lower than the road.
With the extreme rains and flooding
we've had recently, we've seen the
stream jump out of its banks on a more
regular basis. We urgently see the
need to invest in stream stabilization and re -vegetation strategies, and we fear
adding another structure in this area will further compromise the function of the
stream protection zone to absorb flood waters, as well as put the structure and its
uses at risk. A recent visit from Kory Kirtland, the NRCS District Conservationist,
and Anne Marie Roberts of the James River Association, both confirmed the
wisdom and benefits of the proposed location.
We first consulted Albemarle County Engineering staff about our plans and their effect
on the stream buffer in November 2019, but were not made aware of any front setback
requirements. In response to our submitted Farm Building Exemption form, County staff
Corbett Barn Variance Application 1 2
ATTACHMENT B
has explained they cannot grant exception to the front setback and must therefore
recommend the structure encroach into the stream protection buffer. This seems to be
an illogical and unfortunate consequence of the usually well-intentioned rules, which is
why we are now applying for a variance to build in the front setback area.
We thank you for working with us to find a mutually beneficial solution, which we all
earnestly believe is in the best interests of the environment, our county, and our lovely
farm. We ultimately and passionately want to take advantage of the existing topography
and site layout, minimizing new land disturbance, protect sensitive areas, and restore
agricultural use of the land. We plan to spend a great deal of time and money repairing
and enhancing the current riparian buffer — so putting the barn further down onto the
property from the current parking area will not only damage the pristine area we are
seeking to preserve — but also contradicts the purpose of the county's stream
protection ordinance in the first place.
We would like to stress that the current topography of the property contains a
parking area just below the road, and that the rest of the land slopes quite steeply
down from there, leaving no space for parking or conveniently accessing
anything (house or barn) other than from this area. Putting the barn 20 feet
further west would require an enormous amount of fill, great expense, and an
extremely unattractive causeway from the current parking/access/entry area to
the barn. The site is tight and the barn will be fairly obscured by a new privacy
fence, and is still out of the riparian buffer we are seeking to remediate. These
plans reflect the best practices and priorities enjoined by the county.
Thanks again for your help and
consideration — we really do
appreciate it.
Michael & Michelle Corbett
Round Top Roots Farm ®RO�IUdNh&VDtT,OP
Corbett Barn Variance Application 1 3
ATTACHMENT B
FRONT / EAST ELEVATION
CORBETT BARN
GEOBARN
k'YL1 I INI-ti I I -I -\/a V 1AI
WIN
Kl(�[lI / NUKI I -I LLLVAI [UN
LET /5UU1 fl CLCVHIIUN
COIRBETT
BARN
AFTON, VIRGINIA
DRAWING TITLE:
COVER
DATE: OG-3-2020
DRAWN BY: DVS
SCALE:
1 /6" = 1 '-0"
REVISIONS
0711012020
07/ 1 G/2020
1010212020
COVER
ATTACHMENT B
r,
0
on
BASEMENT FLOOR PLAN
PROJECT:
CORBETT
BARN
AFTON, VIRGINIA
ARCHITECT OF RECORD:
BUILDER:
GEO5ARN5. LLC
923 KINGS HIGHWAY
WHITE RIVER JCT.. VT OSCO
PHONE: (,502) 359- 191 2
MEP ENGINEER:
STRUCTURAL ENGINE -ER -.-
DRAWING TITLE:
BASEMENT FLOOR
PLAN
DATE: OG-3-2020
DRAWN BY: DMS
SCALE:
1 /4" = 1 '-0"
REVISIONS
07/ 10/2020
07/ 1 G/2020
1010212020
A2.0
ATTACHMENT B
8
t
0
(V
I
u
is
II II II II
II jl II II
II
II II II II
III ICI
I I I I
I I I I
I I I I
I I I I
TRUCK BAY
I T.O. SUBFLOOR I I
ELEV @ 0'-0"
I I I I
I I I I
I I I I
I I I I
I I I 1
I I I I
ICI ICI
I of I of
I¢I Iml
IDZI ICI
I o1 I
IDZI ICI
I N
I hI o
II II
II II II II
II II II II
I; II 11 II
II II 1 11 I
I, I I 11 I I
3
------------ H-----------
LINE OF FLOOR AND WALL ABOVE
FARM EQUIPMENT
T.O. 5UBFLOOR
ELEV @ 0'-0"
26'-T
T.O. SUBFLOOR
ELEV @ 0'-0"
in
FI RST FLOOR PLAN
PROJECT:
CORBETT
BARN
AFTON. VIRGINIA
ARCI11TECT OF RECORD:
BUILDER:
"iIL �I'v'_PJ0 v-i C?i�UG
PhONE-;b02) 32
MEP ENGINEER:
5TRUCTURALENGINEER:
DRAWING TITLE:
FIRST FLOOR PLAN
DATE: OG-3-2020
DRAWN BY: DM5
SCALE:
1 /4" = 1 '-0"
fPEVISIONS
1 07/ 1 0/2020 1
1 07/ 1 G/2020 I
1 1010212020 1
A2. I
ATTACHMENT B
—I a-01
7-O"
3/0 X 3/0 DH
A
7-O
3/0 X 3/0 DH
G'_0" HEADROOM
7-0" HEADROOM
8'-0" HEADROOM
I 3%O X 2/O 3/0 X 2/0 I T.O.5UBFLOOR
B
Z I I I ELEV @ 9'-0"
Q O I �P�ENCUPf�CA I
PT},O
- - -
Z RIDGEE q LINE ABOVE OV R1DGE LINE ABOVEDOWN
— —4,->2t,
3
D
� -- -
_
0
-,Ica
,Iro-
b
N
_
x
N
m
I
-
�
0
44-0"
HEADROOM
— _ — — — — j
— _-
8'-0' HEADROOM
7-0"HEADPy00M
------- _
7'HEADROOM
="
-2 HEADROOM
— —
0 (n n
_0"
HEAD
6'OROOM
2'-0"
2'-0-
II II
II
II I II
II II
II
R00f I
II I
II II
II II
� II
II II
II
IL------------ — — --------------II
L--------------------------------------------- L-J
2 T-G"
SECOND FLOOR PLAN
COR13ETT
BARN
AFTON, VIRGINIA
GEOBARNS. LLC
923 KINGS HIGHWAY
WHITE RIVER JCL.
PHONE: (802) 3S3
hAFP FAVJ
DRAWING TITLE:
SECOND FLOOR
PLAN
DATE: OG-3-2020
DRAWN BY: DMS
SCALE:
1 /4" = I -0"
REVISIONS
07/ 1 0/2020
07/ 1 G/2020
1 0/02/2020
A2.2