HomeMy WebLinkAboutSP202100001 Energy Product Guide Special Use Permit 2019-10-23BiHiKu
SUPER HIGH POWER BIFACIAL POLY PERC MODULE
390W-410W
UP TO 30% MORE POWER FROM THE BACK SIDE
CS3W-3901395140014051410PB-AG
MORE POWER
ExTRA Up to 30% more power from the
POWER backside
24 % more front side power
than conventional modules
Low NMOT: 41 t 3 °C
41°C
Low temperature coefficient(Pmax):
-0.37 % / °C
@ Better shading tolerance
MORE RELIABLE
TLower
internal current,
lower hot spot temperature
Minimizes micro -cracks and
snail trails
* * *
Heavy snow load up to 5400 Pa,
0
wind load up to 2400 Pa
®
Fire Class A and Type 3 / Type 13
*For detail informatiom please refer to Installation Manual.
�� CanadianSolar
rnvimi
bAr N
30 1 linear power output warranty*
years
*""m.....xx✓�F _
2 enhanced product warranty on
* years materials and workmanship*
11
*According to the applicable Canadian Solar Limited Warranty Statement.
MANAGEMENT SYSTEM CERTIFICATES*
ISO 90012015 / Quality management system
ISO 14001:2015 / Standards for environmental management system
OHSAS 18001:2007 / International standards for occupational health & safety
PRODUCT CERTIFICATES*
IEC 61215 / IEC 61730: VDE / CE / MCS / INMETRO
UL 1703 / IEC 61215 performance: CEC listed (US)
UL 1703: CSA / IEC 61701 ED2: VDE / IEC 62716: VDE / IEC 60068-2-68: SGS
Take -a -way
DVE 0. C
* us
As there are different certification requirements in different markets, please contact
your local Canadian Solar sales representative for the specific certificates applicable to
the products in the region in which the products are to be used.
CANADIAN SOLAR INC. is committed to providing high quality
solar products, solar system solutions and services to custo-
mers around the world. No.1 module supplier for quality
and performance/price ratio in IHS Module Customer Insight
Survey. As a leading PV project developer and manufacturer
of solar modules with over 36 GW deployed around the world
since 2001.
CANADIAN SOLAR INC.
545 Speedvale Avenue West, Guelph, Ontario N1 K 1 E6, Canada, www.canadiansolar.com, support@canadiansolar.com
ENGINEERING DRAWING (mm)
Rear View
ELECTRICAL DATA I STC*
Frame Cross Section
A -A B-B
Mounting Hole
CS3W-400PB-AG / I-V CURVES
A A
M
II a
6
5
4
3
2
Nominal
Opt.
Opt.
Open
Short
Max.
Operating
Operating
Circuit
Circuit
Module
Power
Voltage
Current
Voltage Current
Efficiency
(Pmax)
(Vmp)
(Imp)
(VOC)
(Isc)
CS3W-390PB-AG 390 W
38.3 V
10.19 A
46.8 V
10.74 A
17.45%
5% 410 W
38.3 V
10.71 A
46.8 V
11.28 A
18.35%
Bifacial 16429 W
38.3 V
11.21 A
46.8 V
11.81 A
19.20%
Gain** 20% 468 W
38.3 V
12.23 A
46.8 V
12.89 A
20.95%
30% 507 W
38.3 V
13.25 A
46.8 V
13.96 A
22.69%
CS3W-395PB-AG 395 W
38.5 V
10.26 A
47 V
10.82 A
17.68%
5% 415 W
38.5 V
10.78 A
47 V
11.36 A
18.57%
Bifacial 10% 435 W
38.5 V
11.3 A
47 V
11.9 A
19.47%
Gain** 20% 474 W
38.5 V
12.31 A
47 V
12.98 A
21.21 %
30% 513 W
38.5 V
13.34 A
47 V
14.07 A
22.96%
CS3W-400P_B_-AG 400 W
38.7-V
10.34 A
47.2 V
10.9 A
17.90%
5% 420 W
38.7 V
10.86 A
47.2 V
11.45 A
18.80%
Bifacial 10% 440 W
38.7 V
11.37 A
47.2 V
11.99 A
19.69%
Gain** 20% 480 W
38.7 V
12.41 A
47.2 V
13.08 A
21.48%
30% 520 W
38.7 V
13.44 A
47.2 V
14.17 A
23.27%
CS3W--405PB-AG 405 W
38.9 V
10.42 A
47.4 V
10.98 A
18.13%
5% 425 W
38.9 V
10.94 A
47.4 V
11.53 A
19.02%
Bifacial 10% 445 W
38.9 V
11.46 A
47.4 V
12.08 A
19.92%
Gain** 20% 486 W
38.9 V
12.5 A
47.4 V
13.18 A
21.75%
30% 527 W
38.9 V
13.56 A
47A V
14.27 A
23.59%
CS3W-410PB-AG 410 W
39.1 V
10.49 A
47.6 V
11.06 A
18.35%
5% 431 W
39.1 V
11.03 A
47.6 V
11.61 A
19.29%
Bifacial 10% 451 W
39.1 V
11.54A
47.6V
12.17A
20.18%
Gain** 20%492W
39.1V
12.59A
47.6V
13.27A
22.02%
30% 533 W
39.1 V
13.64 A
47.6 V
14.38 A
25%
*Under Standard Test Conditions
(STC) of irradiance of 1000 W/m2, spectrum AM 1.5
an3.8d cell
temperature of 25-C.
** Bifacial Gain: The additional gain
from the backside compared
to the
power of the front side
at the standard test condition. It depends on mounting (structure, height, tilt angle etc.) and
albedo of the ground.
ELECTRICAL DATA
Operating Temperature
-400C-+85*C
Max. System Voltage
1500 V (IEC/UQ or 1000 V (IEC/UQ
Module Fire Performance
TYPE 3 /Type 13 (UL 1703)
or CLASS A (IEC61730)
Max. Series Fuse Rating
25 A
Application Classification
Class
Power Tolerance
0-+5W
Power Bifaciality*
70 %
* Power Bifaciality= Pmax. / Pmax_ both Pmax,N, and Pmax,m are tested under STC, Bffad-
ality Tolerance: ±5 %
v
5 10 15 20 25 30 35 40 45 W
5 10 15 20 25 30 35 40 45 50
1GW w/W
5-C
&qw/W
25-C
Wow.
45-C
4WW/m'
65-C ■
2W w/m'
ELECTRICAL DATA I NMOT*
Nominal
Opt.
Opt.
Open
Short
Max.
Operating
Operating Circuit
Circuit
Power
Voltage
Current
Voltagge
Current
(Pmax)
(Vmp)
(Imp)
(Voc)
(Isc)
CS3W-390PB-AG 291 W
35.7 V
8.15 A
".0 V
8.66 A
CS3W-395PB-AG 295 W
35.9 V
8.21 A
44.2 V
8.72 A
CS3W-400PB-AG 299W 36.1V 8.27A 44.4V 8.79A
CS3W-405PB-AG 302 W 36.3 V 8.33 A 44.6 V 8.85 A
CS3W-410PB-AG 306 W 36.5 V 8.39 A 44.8 V 8.92 A
* Under Nominal Module Operating Temperature (NMOT), irradiance of 800 W/m'
spectrum AM 1.5, ambient temperature 2WC, wind speed 1 m/s.
MECHANICAL DATA
Specification
Data
Cell Type
Poly -crystalline
Cell Arrangement
144 [2X (12 X6) ]
Dimensions
2132 x 1048 x 30 mm (83.9 x 41.3 x 1.2 in)
Weight
28.2 kg (62.2 Ibs)
Front / Back Glass
2.0 mm heat strengthened glass
Frame
Anodized aluminium alloy
J-Box
IP68, 3 diodes
Cable
4.0 mm2 (IEC), 12 AWG (UL)
Portrait: 400 mm (15.7 in) (+) / 280 mm
Cable Length (Inclu-
(11.0 in) (-); landscape: 1400 mm (55.1
ding Connector)
in); leap -frog connection: 1850 mm (72.8
in)*
Connector
T4 series or H4 UTX or MC4-EV02
Per Pallet 35 pieces
Per Container (40' HQ) 700 pieces
or 560 pieces (only for US
* For detailed information, please contact your local Canadian Solar sales and
technical representatives.
TEMPERATURE CHARACTERISTICS
Specification Data
Temperature Coefficient (Pmax) -0.37 %/ *C
Temperature Coefficient (Voc) -0.29 %/ °C
Temperature Coefficient (Isc) 0.05 % / °C
Nominal Module Operating Temperature 41 ±30C
PARTNER SECTION
* The specifications and key features contained in this datasheet may deviate slightly from our
actual products due to the on -going innovation and product enhancement. Canadian Solar Inc.
reserves the right to make necessary adjustment to the information described herein at any time
without further notice.
Please be kindly advised that PV modules should be handled and installed by qualified people
who have professional skills and please carefully read the safety and installation instructions
beforeusing our PV modules. ':................................................................................................................. :
CANADIAN SOLAR INC.
545 Speedvale Avenue West, Guelph, Ontario N1 K 1 E6, Canada, www.canadiansolar.com, support@canadiansolar.com
October 2019. All rights reserved, PV Module Product Catasheet V5.584EN
Preliminary Datasheet
100/125kW, 1500Vdc String Inverters for North America
f/CPS
CPS SCH100/125KTL-DO/US-600
■
The 100 & 125kW medium power CPS three phase string inverters are designed for ground mount applications. The units are high
performance, advanced and reliable inverters designed specifically for the North American environment and grid. High efficiency at
99.0% peak and 98.5% CEC, wide operating voltages, broad temperature ranges and a NEMA Type 4X enclosure enable this inverter
platform to operate at high performance across many applications. The CPS 100/125kW products ship with the standard wire -box,
each fully integrated and separable with touch safe fusing, monitoring, and AC and DC disconnect switches. The CPS Flex Gateway
enables communication, controls and remote product upgrades.
Key Features
■ NEC 2014/17 compliant & UL listed Arc -Fault circuit protection
■ Touch safe DC Fuse holders adds convenience and safety
■ CPS Flex Gateway enables remote FW upgrades
■ Integrated AC & DC disconnect switches
■ 1MPPTwith 16and 20inputs for maximum flexibility
■ Copper and Aluminum compatible AC connections
en 100/125kW Standard Wire -box
F
w 522
woinwusnmi FC
mxamammawwu
(alloWpQQlxXatpI.101 pR\501MefIXWM
■ NEMAType 4X outdoor rated, tough tested enclosure
■ Advanced Smart -Grid features (CA Rule 21 compatible)
■ kVA Headroom yields 100kW @ 0.9PF and 125kW @ 0.95PF
■ Generous 1.5 DC/AC Inverter Load Ratio
■ Separable wire -box design for fast service
■ Standard 10 year warranty with extensions to 20 years
100/125kW Centralized Wire -box
0 CHINT POWER 2018/03-MKT NA Chint Power Systems America
7060 Koll Center Parkway, Suite 318 Pleasanton, CA 94566
Tel 855-584-7168 Mail: AmericaSales@chintpoweccom Web: www.chintpowersystems.com
Technical Data
Model Name
CPS SCA100KTL-DO/US-600 CPS SCA125KTL-DO/US-600
DC Input
Max. PV Power
150kW 187.5kW
Max. DC Input Voltage
1500V
Operating DC Input Voltage Range
860-1450Vdc
Start-up DC Input Voltage / Power
900V / 250W
Number of MPP Trackers
1
MPPT Voltage Range
870-1300Vdc
Max. PV Input Current (Ise x1.25)
220A 275A
Number of DC Inputs
16 inputs 20 inputs
DC Disconnection Type
Load rated DC switch
DC Surge Protection
Type II MOV, Up=2.5kV , In=20kA(820us)
AC Output
Rated AC Output Power
100kW 125kW
Max. AC Output Pourer'
100kVA (111 KVA @ PF>0.9) 125kVA (132KVA @ PF>0.95)
Rated Output Voltage
600Vac
Output Voltage Range'
528-660Vac
Grid Connection Type'
30 / PE / N (Neutral optional)
Nominal AC Output Current @600Vac
106.9A 127.2A
Rated Output Frequency
60Hz
Output Frequency Range'
57-63Hz
Pourer Factor
>0.99 (f0.8 adjustable) >0.99 (t0.8 adjustable)
Cunent THD
<3%
AC Disconnection Type
Load rated AC sWtch (Standard Wkre box only)
AC Surge Protection
Type II MOV, Up=2.5kV , In=20kA(8/20us)
System
Topology
Transfomlerless
Max. Efficiency
99.0%
CEC Efficiency
98.5%
Stand-by / Night Consumption
<2W
Environment
Enclosure Protection Degree
NEMA Type 4X
Cooling Method
Variable speed cooling fans
Operating Temperature Range
-22aF to+140aF /-30°C to+60aC (defating from +113°F /+45°C)
Non -Operating Temperature Range°
40aF to +158aF / 40aC to +70aC maximum°
Operating Humidity
0-100%
Operating Altitude
8202ft / 2500m (no derating)
Audible Noise
<65dBA@im and 25°C
Display and Communication
User Interface and Display
LED Indicators, WiR+APP
Inverter Monitoring
Modbus RS485, PLC Option (Standard Wire -box only)
Site Level Monitoring
CPS Flex Gateway (1 per 64 inverters)
Modbus Data Mapping
SunSpedCPS
Remote Diagnosbcs/FW Upgrade Functions
Standard
Mechanical
Dimensions (WxHxD)
45.28x24.25x9.B4in (1150x616x250mm) width Standard Wire -box
39.37x24.254.84in (1000416x250mm) with Centralized Wire -box
Weight
Inverter: 121lbs / 55kg; Wire -box: 55lbs / 25kg (standard); 33lbs / 15kg (centralized)
Mounting/Installation Angle
15 - 90 degrees from horizontal (vertical, angled)
AC Termination'
M8 Stud Type Terminal Block (Wire range: #6 - 3/OAWG CU/AL6, Lugs not supplied)
DC Termination
Screw Clamp Fuse Holder (Wire range: #12 -#64WG CU) - Standard Wire -box
Busbar, M8 PEMserts (Wire range: #tAWG - 250kcmil CU/AL, Lugs not supplied) - Centralized Wire -box
Fused String Inputs
20A fuses provided (Fuse values of 15/25/30A available)
Safety
Safety and EMC Standard
UL1741SA-20166, UL1699B, CSA-C22.2 NO.107.1-01, IEEE1547a-2014; FCC PART15
Grid Standard
IEEE 1547a-2014, CA Rule 216
Smart -Grid Features
Voltage-RideThru, Frequency-RideThru, Soft -Start, Voft-Var, Frequency -Watt
Warranty
Standard
10 years
Extended Terms
15 and 20 years
1)'ass.AC Ai .P.e'Ming vWW xBM1in MPPTwldge nrpeaMlempenture rm.do Cb N'C (-22 ..V4"F)bt IMM PFa0.5 u 1]SoN PF a0.55
2)TM-0u1 Voltl aflm "aM-0N Fr wq amge"mry difv au ine
b ft specific end tlaMazd
])Wye.,A,r d. Dell may rot be cerrer9rowitletl.
4)8 �mamel br WN rrequireme re ring -mi.-
5)R requires bi.moallic mmpr mlug w WmH Iic Mapter.
61 Ge atiom PeMing.
0 nextracker nextracker.com
A Flex Company
Serving as the backbone on over 35 gigawatts of solar power plants around the world,
the NX Horizon'n' smart solar tracker system combines best -in -class hardware and software
to help EPCs and asset owners maximize performance and minimize operational costs.
Flexible and Resilient by Design
With its self -aligning module rails and vibration -proof fasteners, NX Horizon can
be easily and rapidly installed. The self -powered, decentralized architecture
allows each row to be commissioned in advance of site power, and is
designed to withstand high winds and other adverse weather conditions.
On a recent 838 megawatt project in Villanueva, Mexico, these design
features allowed for the project to go online nine months ahead of schedule.
TrueCapture and Bifacial Enabled
Incorporating the most promising innovations in utility scale solar,
NX Horizon with TrueCapture'" smart control system can add additional
energy production by up to six percent. Further unlocking the advantages
of independent -row architecture and the data collected from thousands
of sensors across its built-in wireless network, the software continuously
optimizes the tracking algorithm of each row in response to site terrain and
changing weather conditions. NX Horizon can also be paired with bifacial
PV module technology, which can provide even more energy harvest and
performance. With bifacial technology, NX Horizon outperforms conventional
tracking systems with over 1% more annual energy.
Quality and Reliability from Day One
Quality and reliability are designed and tested into every NX Horizon
component and system across our supply chain and manufacturing
operations. Nextracker is the leader in dynamic wind analysis and safety
stowing, delivering major benefits in uptime and long-term durability
NX Horizon is certified to UL 2703 and UL 3703 standards, underscoring
Nextracker's commitment to safety, reliability and quality.
Features and
Benefits
5 years in a row
Global Market Share Leader (2015-18)
35 Gw
Delivered on 5 Continents
Best -in Class
Software Ecosystem and
Global Services
Up to 6%
Using TrueCapture Smart
Control System
GENERAL AND MECHANICAL
Tracking type
Horizontal single -axis, independent row.
String voltage
1,500 V. orl,000 V..
Typical row size
78-90 modules, depending on module
string length.
Drive type
Non-backdriving, high accuracy slew gear.
Motortype
24 V brushless DC motor
Array height
Rotation axis elevation
1.3 to 1.8 m /4'3"to 5'10"
Ground coverage
ratio (OCR)
Configurable. Typical range 28-50%.
Mounting options available for virtually all
Modules supported
utility -scale crystalline modules, First Solar
Series 6 and First Solar Series 4.
Bifacial features
High-rise mounting rails. bearing +driveline
gaps and round torque tube.
Tracking range
of motion
Options for 360°or 350'
Operating
SELF POWERED:-30°C to 55-C(--22°F to 131°F)
temperature range
AC POWERED:-40°C to 55°C(--40°F to 131"F)
1 in portrait.3 x 1,500 V or 4 x 1,000 V strings
Module configuration
per standard tracker. Partial length
trackers available.
Module attachment
Self -grounding, electric
tool -actuated fasteners.
Materials
Galvanized steel
Configurable up to 225 kph (140 mph)
Allowable wind speed
3-second gust
Intelligent wind stowing with symmetric
Wind protection
dampers for maximum array stability in
all wind conditions
Foundations
Standard W6 section foundation posts
ELECTRONICS AND CONTROLS
Astronomical algorithm with backtracking
Solar tracking method
TrueCapture— upgrades available for
terrain adaptive backtracking and diffuse
tracking mode
Control electronics
NX tracker controller with inbuilt
inclinometer and backup battery
Zlgbee wireless communications to all
Communications
tracker rows and weather stations via
network control units (NCUS)
Nighttime stow
Yes
SELF POWERED: NX provided 30 or 60W
Smart Panel
Power supply
AC POWERED: Customer -provided
120-240 W.circut
INSTALLATION, OPERATIONS AND SERVICE
PE stamped structural
calculations and
Included
drawings
Onsite training and
Included
systemcommissioning
Installation
Simple assembly using swaged fasteners
requirements
and bolted connections. No field cutting,
drilling or welding.
Monitoring
NX Data Hub- centralized data aggregation
and monitoring
Module cleaning
Compatible with NX qualified
compatibility
cleaning systems
Warranty
10-year structural, 5-year
drive and control components.
Codes and standards
UL 3703 / UL 2703 / IEC 62817
C Nextracker Inc. Contents subject to change without notice.
6200 Paseo Padre Parkway I Fremont, CA 945551 USA 1+1510 270 25001 nextracker.com
MKT-000060-C
® BATTERY ENERGY
STORAGE SYSTEM
POWIN BATTERY ENCLOSURE
POWIN SMART ENCLOSURES
Powin Energy's cost effective smart enclosures are a scalable
purpose-built battery solution that includes all of the
balance of system (BOS) equipment that can be modified
to meet local AHJ requirements. The thermal management
of this enclosure has been meticulously designed through
air ducting and HVAC, providing an optimal temperature
controlled environment for the battery enabling deployment
in many different geographical climate types. Powin Smart
Enclosures come in 20r , 4o° and 53FT sizes.
FULLY INTEGRATED
+ Up to zo Stack225s or Stack230s per enclosure in parallel
+ Powin's patented StackOS integrated Battery Management
and Energy Management Platform
+ HVAC &forced airwith ducting that directly targets the stacks
PPowin Energy
+ AC breaker panel for coms and aux loads
+ Fire suppression system that also provides detection
and monitoring
+ DC Collection, cable and tray
+ I P 54 rated
+ Insulation options for hot and cold climates
+ Isolation, and over current and fault protection
+ Minimal on site installation requirements
COMMUNICATION CABINET
+ Full state of awareness monitoring for fire suppression/
HVAC/inverter and transformer status/E stop/UPS aux
+ Switch
+ Router
+ UPS - Control
+ Linux computer
+ HMI
+ Controls interface can connect to any SCADA system
anPOWIN ENERGY ENCLOSURES
TECHNICAL SPECIFICATIONS Powin
MODELI
Stack Product
ENCLOSURE
Stack225 Stack230
40" ENCLOSURE
Stack230P St3ck225 Stack23o
S31"ENCLOSURE
Stack225 Stack230
Battery Chemistry
Lithium Iron Phosphate [LFP]
Integrated BMS • EMS
StackOS"
Rated BC Power (kW)
66o
345
2100
1540
805
2200
1150
Maximum OC Energy*
1350
1380
3220
3150
3290
4500
46o0
Duration @ Rated Power [hrs]
z
4
1.5
z
4
2
4
DC Voltage Range
76o-963 vDc
Max Current (A)
1o8o 540
2870 25z0 126o
1800 x z 90o x z
Depth of Oischarge
100%
DC RoundTdp Efficiency@ Rated Power('Ya
93%
91%
93%
Performance Guarantee
8o% SoH after 3,65o
cycles Or70%SoH
after 15 yrs
66.5%SoH after 7,3oo
cycles Or70%SoH
after zo years
8o% SoH after 5,840
cyclesor8o%SoH
after 16 yrs
8o% SoH after 3,650
cyclesOr7o%SOH
after 15 years
66.5% SoH after 7,300
cycles Or70%SoH
after zo years
8o% SoH after 3,650
cycles Or70%SoH
after 15 yrs
66.5%SoH after 7,300
cycles Or70%SoH
after 20 years
Weight Jibs / kg]
42,i25 / 19,to8
90,500 / 41,050
126,455 / 57,36o
Dimensions
19'10.2" L x 8'w x 9'6"H
40'Lx 8'wx 9'6"H
53 Lx 8'wx9'6"H
Enclosure Type / Rating
150 HC / NEMA3 / IP54
Ambient Temperature Range
-10 to +50 °c
Number of Stacks
6
14
20
Energy Density [kWh /W2]
7.73 1 8.08
9.15 8.95 936
9-65 10.09
Fire Suppression
Included with Fire Suppression Agent, Fire Detection Panels with Sensors, Pull Handle, and Lights, and FDC dry standpipe connection
Cooling
Dual Redundant Forced Air HVAC with Thermostat, Humidity Control, & Economizer
OC Collection, Cable Tray, AC Load Panel
Included
Code and Standards Compliance
UL1973, UL9540A, IEC62619, NFPAS55, IS01496-1
*Usable energy for fully populated container; Actual usable energy varies by use case and DC topology; Contact Powin for an accurate estimate
ABOUT POWIN ENERGY
Powin Energy is creating the next wave of safe and scalable battery energy storage that is purpose-built for the demands of utility -scale, commercial and industrial,
and microgrid applications. With an unrivaled team of experts from across the energy industry, almost three decades of supply chain management expertise, extensive
battery management software proficiency, a modular architecture, and a streamlined installation processes, Powin is making energy storage highly cost-effective
and relatively pain free.