Loading...
HomeMy WebLinkAboutSP202100001 Energy Product Guide Special Use Permit 2019-10-23BiHiKu SUPER HIGH POWER BIFACIAL POLY PERC MODULE 390W-410W UP TO 30% MORE POWER FROM THE BACK SIDE CS3W-3901395140014051410PB-AG MORE POWER ExTRA Up to 30% more power from the POWER backside 24 % more front side power than conventional modules Low NMOT: 41 t 3 °C 41°C Low temperature coefficient(Pmax): -0.37 % / °C @ Better shading tolerance MORE RELIABLE TLower internal current, lower hot spot temperature Minimizes micro -cracks and snail trails * * * Heavy snow load up to 5400 Pa, 0 wind load up to 2400 Pa ® Fire Class A and Type 3 / Type 13 *For detail informatiom please refer to Installation Manual. �� CanadianSolar rnvimi bAr N 30 1 linear power output warranty* years *""m.....xx✓�F _ 2 enhanced product warranty on * years materials and workmanship* 11 *According to the applicable Canadian Solar Limited Warranty Statement. MANAGEMENT SYSTEM CERTIFICATES* ISO 90012015 / Quality management system ISO 14001:2015 / Standards for environmental management system OHSAS 18001:2007 / International standards for occupational health & safety PRODUCT CERTIFICATES* IEC 61215 / IEC 61730: VDE / CE / MCS / INMETRO UL 1703 / IEC 61215 performance: CEC listed (US) UL 1703: CSA / IEC 61701 ED2: VDE / IEC 62716: VDE / IEC 60068-2-68: SGS Take -a -way DVE 0. C * us As there are different certification requirements in different markets, please contact your local Canadian Solar sales representative for the specific certificates applicable to the products in the region in which the products are to be used. CANADIAN SOLAR INC. is committed to providing high quality solar products, solar system solutions and services to custo- mers around the world. No.1 module supplier for quality and performance/price ratio in IHS Module Customer Insight Survey. As a leading PV project developer and manufacturer of solar modules with over 36 GW deployed around the world since 2001. CANADIAN SOLAR INC. 545 Speedvale Avenue West, Guelph, Ontario N1 K 1 E6, Canada, www.canadiansolar.com, support@canadiansolar.com ENGINEERING DRAWING (mm) Rear View ELECTRICAL DATA I STC* Frame Cross Section A -A B-B Mounting Hole CS3W-400PB-AG / I-V CURVES A A M II a 6 5 4 3 2 Nominal Opt. Opt. Open Short Max. Operating Operating Circuit Circuit Module Power Voltage Current Voltage Current Efficiency (Pmax) (Vmp) (Imp) (VOC) (Isc) CS3W-390PB-AG 390 W 38.3 V 10.19 A 46.8 V 10.74 A 17.45% 5% 410 W 38.3 V 10.71 A 46.8 V 11.28 A 18.35% Bifacial 16429 W 38.3 V 11.21 A 46.8 V 11.81 A 19.20% Gain** 20% 468 W 38.3 V 12.23 A 46.8 V 12.89 A 20.95% 30% 507 W 38.3 V 13.25 A 46.8 V 13.96 A 22.69% CS3W-395PB-AG 395 W 38.5 V 10.26 A 47 V 10.82 A 17.68% 5% 415 W 38.5 V 10.78 A 47 V 11.36 A 18.57% Bifacial 10% 435 W 38.5 V 11.3 A 47 V 11.9 A 19.47% Gain** 20% 474 W 38.5 V 12.31 A 47 V 12.98 A 21.21 % 30% 513 W 38.5 V 13.34 A 47 V 14.07 A 22.96% CS3W-400P_B_-AG 400 W 38.7-V 10.34 A 47.2 V 10.9 A 17.90% 5% 420 W 38.7 V 10.86 A 47.2 V 11.45 A 18.80% Bifacial 10% 440 W 38.7 V 11.37 A 47.2 V 11.99 A 19.69% Gain** 20% 480 W 38.7 V 12.41 A 47.2 V 13.08 A 21.48% 30% 520 W 38.7 V 13.44 A 47.2 V 14.17 A 23.27% CS3W--405PB-AG 405 W 38.9 V 10.42 A 47.4 V 10.98 A 18.13% 5% 425 W 38.9 V 10.94 A 47.4 V 11.53 A 19.02% Bifacial 10% 445 W 38.9 V 11.46 A 47.4 V 12.08 A 19.92% Gain** 20% 486 W 38.9 V 12.5 A 47.4 V 13.18 A 21.75% 30% 527 W 38.9 V 13.56 A 47A V 14.27 A 23.59% CS3W-410PB-AG 410 W 39.1 V 10.49 A 47.6 V 11.06 A 18.35% 5% 431 W 39.1 V 11.03 A 47.6 V 11.61 A 19.29% Bifacial 10% 451 W 39.1 V 11.54A 47.6V 12.17A 20.18% Gain** 20%492W 39.1V 12.59A 47.6V 13.27A 22.02% 30% 533 W 39.1 V 13.64 A 47.6 V 14.38 A 25% *Under Standard Test Conditions (STC) of irradiance of 1000 W/m2, spectrum AM 1.5 an3.8d cell temperature of 25-C. ** Bifacial Gain: The additional gain from the backside compared to the power of the front side at the standard test condition. It depends on mounting (structure, height, tilt angle etc.) and albedo of the ground. ELECTRICAL DATA Operating Temperature -400C-+85*C Max. System Voltage 1500 V (IEC/UQ or 1000 V (IEC/UQ Module Fire Performance TYPE 3 /Type 13 (UL 1703) or CLASS A (IEC61730) Max. Series Fuse Rating 25 A Application Classification Class Power Tolerance 0-+5W Power Bifaciality* 70 % * Power Bifaciality= Pmax. / Pmax_ both Pmax,N, and Pmax,m are tested under STC, Bffad- ality Tolerance: ±5 % v 5 10 15 20 25 30 35 40 45 W 5 10 15 20 25 30 35 40 45 50 1GW w/W 5-C &qw/W 25-C Wow. 45-C 4WW/m' 65-C ■ 2W w/m' ELECTRICAL DATA I NMOT* Nominal Opt. Opt. Open Short Max. Operating Operating Circuit Circuit Power Voltage Current Voltagge Current (Pmax) (Vmp) (Imp) (Voc) (Isc) CS3W-390PB-AG 291 W 35.7 V 8.15 A ".0 V 8.66 A CS3W-395PB-AG 295 W 35.9 V 8.21 A 44.2 V 8.72 A CS3W-400PB-AG 299W 36.1V 8.27A 44.4V 8.79A CS3W-405PB-AG 302 W 36.3 V 8.33 A 44.6 V 8.85 A CS3W-410PB-AG 306 W 36.5 V 8.39 A 44.8 V 8.92 A * Under Nominal Module Operating Temperature (NMOT), irradiance of 800 W/m' spectrum AM 1.5, ambient temperature 2WC, wind speed 1 m/s. MECHANICAL DATA Specification Data Cell Type Poly -crystalline Cell Arrangement 144 [2X (12 X6) ] Dimensions 2132 x 1048 x 30 mm (83.9 x 41.3 x 1.2 in) Weight 28.2 kg (62.2 Ibs) Front / Back Glass 2.0 mm heat strengthened glass Frame Anodized aluminium alloy J-Box IP68, 3 diodes Cable 4.0 mm2 (IEC), 12 AWG (UL) Portrait: 400 mm (15.7 in) (+) / 280 mm Cable Length (Inclu- (11.0 in) (-); landscape: 1400 mm (55.1 ding Connector) in); leap -frog connection: 1850 mm (72.8 in)* Connector T4 series or H4 UTX or MC4-EV02 Per Pallet 35 pieces Per Container (40' HQ) 700 pieces or 560 pieces (only for US * For detailed information, please contact your local Canadian Solar sales and technical representatives. TEMPERATURE CHARACTERISTICS Specification Data Temperature Coefficient (Pmax) -0.37 %/ *C Temperature Coefficient (Voc) -0.29 %/ °C Temperature Coefficient (Isc) 0.05 % / °C Nominal Module Operating Temperature 41 ±30C PARTNER SECTION * The specifications and key features contained in this datasheet may deviate slightly from our actual products due to the on -going innovation and product enhancement. Canadian Solar Inc. reserves the right to make necessary adjustment to the information described herein at any time without further notice. Please be kindly advised that PV modules should be handled and installed by qualified people who have professional skills and please carefully read the safety and installation instructions beforeusing our PV modules. ':................................................................................................................. : CANADIAN SOLAR INC. 545 Speedvale Avenue West, Guelph, Ontario N1 K 1 E6, Canada, www.canadiansolar.com, support@canadiansolar.com October 2019. All rights reserved, PV Module Product Catasheet V5.584EN Preliminary Datasheet 100/125kW, 1500Vdc String Inverters for North America f/CPS CPS SCH100/125KTL-DO/US-600 ■ The 100 & 125kW medium power CPS three phase string inverters are designed for ground mount applications. The units are high performance, advanced and reliable inverters designed specifically for the North American environment and grid. High efficiency at 99.0% peak and 98.5% CEC, wide operating voltages, broad temperature ranges and a NEMA Type 4X enclosure enable this inverter platform to operate at high performance across many applications. The CPS 100/125kW products ship with the standard wire -box, each fully integrated and separable with touch safe fusing, monitoring, and AC and DC disconnect switches. The CPS Flex Gateway enables communication, controls and remote product upgrades. Key Features ■ NEC 2014/17 compliant & UL listed Arc -Fault circuit protection ■ Touch safe DC Fuse holders adds convenience and safety ■ CPS Flex Gateway enables remote FW upgrades ■ Integrated AC & DC disconnect switches ■ 1MPPTwith 16and 20inputs for maximum flexibility ■ Copper and Aluminum compatible AC connections en 100/125kW Standard Wire -box F w 522 woinwusnmi FC mxamammawwu (alloWpQQlxXatpI.101 pR\501MefIXWM ■ NEMAType 4X outdoor rated, tough tested enclosure ■ Advanced Smart -Grid features (CA Rule 21 compatible) ■ kVA Headroom yields 100kW @ 0.9PF and 125kW @ 0.95PF ■ Generous 1.5 DC/AC Inverter Load Ratio ■ Separable wire -box design for fast service ■ Standard 10 year warranty with extensions to 20 years 100/125kW Centralized Wire -box 0 CHINT POWER 2018/03-MKT NA Chint Power Systems America 7060 Koll Center Parkway, Suite 318 Pleasanton, CA 94566 Tel 855-584-7168 Mail: AmericaSales@chintpoweccom Web: www.chintpowersystems.com Technical Data Model Name CPS SCA100KTL-DO/US-600 CPS SCA125KTL-DO/US-600 DC Input Max. PV Power 150kW 187.5kW Max. DC Input Voltage 1500V Operating DC Input Voltage Range 860-1450Vdc Start-up DC Input Voltage / Power 900V / 250W Number of MPP Trackers 1 MPPT Voltage Range 870-1300Vdc Max. PV Input Current (Ise x1.25) 220A 275A Number of DC Inputs 16 inputs 20 inputs DC Disconnection Type Load rated DC switch DC Surge Protection Type II MOV, Up=2.5kV , In=20kA(820us) AC Output Rated AC Output Power 100kW 125kW Max. AC Output Pourer' 100kVA (111 KVA @ PF>0.9) 125kVA (132KVA @ PF>0.95) Rated Output Voltage 600Vac Output Voltage Range' 528-660Vac Grid Connection Type' 30 / PE / N (Neutral optional) Nominal AC Output Current @600Vac 106.9A 127.2A Rated Output Frequency 60Hz Output Frequency Range' 57-63Hz Pourer Factor >0.99 (f0.8 adjustable) >0.99 (t0.8 adjustable) Cunent THD <3% AC Disconnection Type Load rated AC sWtch (Standard Wkre box only) AC Surge Protection Type II MOV, Up=2.5kV , In=20kA(8/20us) System Topology Transfomlerless Max. Efficiency 99.0% CEC Efficiency 98.5% Stand-by / Night Consumption <2W Environment Enclosure Protection Degree NEMA Type 4X Cooling Method Variable speed cooling fans Operating Temperature Range -22aF to+140aF /-30°C to+60aC (defating from +113°F /+45°C) Non -Operating Temperature Range° 40aF to +158aF / 40aC to +70aC maximum° Operating Humidity 0-100% Operating Altitude 8202ft / 2500m (no derating) Audible Noise <65dBA@im and 25°C Display and Communication User Interface and Display LED Indicators, WiR+APP Inverter Monitoring Modbus RS485, PLC Option (Standard Wire -box only) Site Level Monitoring CPS Flex Gateway (1 per 64 inverters) Modbus Data Mapping SunSpedCPS Remote Diagnosbcs/FW Upgrade Functions Standard Mechanical Dimensions (WxHxD) 45.28x24.25x9.B4in (1150x616x250mm) width Standard Wire -box 39.37x24.254.84in (1000416x250mm) with Centralized Wire -box Weight Inverter: 121lbs / 55kg; Wire -box: 55lbs / 25kg (standard); 33lbs / 15kg (centralized) Mounting/Installation Angle 15 - 90 degrees from horizontal (vertical, angled) AC Termination' M8 Stud Type Terminal Block (Wire range: #6 - 3/OAWG CU/AL6, Lugs not supplied) DC Termination Screw Clamp Fuse Holder (Wire range: #12 -#64WG CU) - Standard Wire -box Busbar, M8 PEMserts (Wire range: #tAWG - 250kcmil CU/AL, Lugs not supplied) - Centralized Wire -box Fused String Inputs 20A fuses provided (Fuse values of 15/25/30A available) Safety Safety and EMC Standard UL1741SA-20166, UL1699B, CSA-C22.2 NO.107.1-01, IEEE1547a-2014; FCC PART15 Grid Standard IEEE 1547a-2014, CA Rule 216 Smart -Grid Features Voltage-RideThru, Frequency-RideThru, Soft -Start, Voft-Var, Frequency -Watt Warranty Standard 10 years Extended Terms 15 and 20 years 1)'ass.AC Ai .P.e'Ming vWW xBM1in MPPTwldge nrpeaMlempenture rm.do Cb N'C (-22 ..V4"F)bt IMM PFa0.5 u 1]SoN PF a0.55 2)TM-0u1 Voltl aflm "aM-0N Fr wq amge"mry difv au ine b ft specific end tlaMazd ])Wye.,A,r d. Dell may rot be cerrer9rowitletl. 4)8 �mamel br WN rrequireme re ring -mi.- 5)R requires bi.moallic mmpr mlug w WmH Iic Mapter. 61 Ge atiom PeMing. 0 nextracker nextracker.com A Flex Company Serving as the backbone on over 35 gigawatts of solar power plants around the world, the NX Horizon'n' smart solar tracker system combines best -in -class hardware and software to help EPCs and asset owners maximize performance and minimize operational costs. Flexible and Resilient by Design With its self -aligning module rails and vibration -proof fasteners, NX Horizon can be easily and rapidly installed. The self -powered, decentralized architecture allows each row to be commissioned in advance of site power, and is designed to withstand high winds and other adverse weather conditions. On a recent 838 megawatt project in Villanueva, Mexico, these design features allowed for the project to go online nine months ahead of schedule. TrueCapture and Bifacial Enabled Incorporating the most promising innovations in utility scale solar, NX Horizon with TrueCapture'" smart control system can add additional energy production by up to six percent. Further unlocking the advantages of independent -row architecture and the data collected from thousands of sensors across its built-in wireless network, the software continuously optimizes the tracking algorithm of each row in response to site terrain and changing weather conditions. NX Horizon can also be paired with bifacial PV module technology, which can provide even more energy harvest and performance. With bifacial technology, NX Horizon outperforms conventional tracking systems with over 1% more annual energy. Quality and Reliability from Day One Quality and reliability are designed and tested into every NX Horizon component and system across our supply chain and manufacturing operations. Nextracker is the leader in dynamic wind analysis and safety stowing, delivering major benefits in uptime and long-term durability NX Horizon is certified to UL 2703 and UL 3703 standards, underscoring Nextracker's commitment to safety, reliability and quality. Features and Benefits 5 years in a row Global Market Share Leader (2015-18) 35 Gw Delivered on 5 Continents Best -in Class Software Ecosystem and Global Services Up to 6% Using TrueCapture Smart Control System GENERAL AND MECHANICAL Tracking type Horizontal single -axis, independent row. String voltage 1,500 V. orl,000 V.. Typical row size 78-90 modules, depending on module string length. Drive type Non-backdriving, high accuracy slew gear. Motortype 24 V brushless DC motor Array height Rotation axis elevation 1.3 to 1.8 m /4'3"to 5'10" Ground coverage ratio (OCR) Configurable. Typical range 28-50%. Mounting options available for virtually all Modules supported utility -scale crystalline modules, First Solar Series 6 and First Solar Series 4. Bifacial features High-rise mounting rails. bearing +driveline gaps and round torque tube. Tracking range of motion Options for 360°or 350' Operating SELF POWERED:-30°C to 55-C(--22°F to 131°F) temperature range AC POWERED:-40°C to 55°C(--40°F to 131"F) 1 in portrait.3 x 1,500 V or 4 x 1,000 V strings Module configuration per standard tracker. Partial length trackers available. Module attachment Self -grounding, electric tool -actuated fasteners. Materials Galvanized steel Configurable up to 225 kph (140 mph) Allowable wind speed 3-second gust Intelligent wind stowing with symmetric Wind protection dampers for maximum array stability in all wind conditions Foundations Standard W6 section foundation posts ELECTRONICS AND CONTROLS Astronomical algorithm with backtracking Solar tracking method TrueCapture— upgrades available for terrain adaptive backtracking and diffuse tracking mode Control electronics NX tracker controller with inbuilt inclinometer and backup battery Zlgbee wireless communications to all Communications tracker rows and weather stations via network control units (NCUS) Nighttime stow Yes SELF POWERED: NX provided 30 or 60W Smart Panel Power supply AC POWERED: Customer -provided 120-240 W.circut INSTALLATION, OPERATIONS AND SERVICE PE stamped structural calculations and Included drawings Onsite training and Included systemcommissioning Installation Simple assembly using swaged fasteners requirements and bolted connections. No field cutting, drilling or welding. Monitoring NX Data Hub- centralized data aggregation and monitoring Module cleaning Compatible with NX qualified compatibility cleaning systems Warranty 10-year structural, 5-year drive and control components. Codes and standards UL 3703 / UL 2703 / IEC 62817 C Nextracker Inc. Contents subject to change without notice. 6200 Paseo Padre Parkway I Fremont, CA 945551 USA 1+1510 270 25001 nextracker.com MKT-000060-C ® BATTERY ENERGY STORAGE SYSTEM POWIN BATTERY ENCLOSURE POWIN SMART ENCLOSURES Powin Energy's cost effective smart enclosures are a scalable purpose-built battery solution that includes all of the balance of system (BOS) equipment that can be modified to meet local AHJ requirements. The thermal management of this enclosure has been meticulously designed through air ducting and HVAC, providing an optimal temperature controlled environment for the battery enabling deployment in many different geographical climate types. Powin Smart Enclosures come in 20r , 4o° and 53FT sizes. FULLY INTEGRATED + Up to zo Stack225s or Stack230s per enclosure in parallel + Powin's patented StackOS integrated Battery Management and Energy Management Platform + HVAC &forced airwith ducting that directly targets the stacks PPowin Energy + AC breaker panel for coms and aux loads + Fire suppression system that also provides detection and monitoring + DC Collection, cable and tray + I P 54 rated + Insulation options for hot and cold climates + Isolation, and over current and fault protection + Minimal on site installation requirements COMMUNICATION CABINET + Full state of awareness monitoring for fire suppression/ HVAC/inverter and transformer status/E stop/UPS aux + Switch + Router + UPS - Control + Linux computer + HMI + Controls interface can connect to any SCADA system anPOWIN ENERGY ENCLOSURES TECHNICAL SPECIFICATIONS Powin MODELI Stack Product ENCLOSURE Stack225 Stack230 40" ENCLOSURE Stack230P St3ck225 Stack23o S31"ENCLOSURE Stack225 Stack230 Battery Chemistry Lithium Iron Phosphate [LFP] Integrated BMS • EMS StackOS" Rated BC Power (kW) 66o 345 2100 1540 805 2200 1150 Maximum OC Energy* 1350 1380 3220 3150 3290 4500 46o0 Duration @ Rated Power [hrs] z 4 1.5 z 4 2 4 DC Voltage Range 76o-963 vDc Max Current (A) 1o8o 540 2870 25z0 126o 1800 x z 90o x z Depth of Oischarge 100% DC RoundTdp Efficiency@ Rated Power('Ya 93% 91% 93% Performance Guarantee 8o% SoH after 3,65o cycles Or70%SoH after 15 yrs 66.5%SoH after 7,3oo cycles Or70%SoH after zo years 8o% SoH after 5,840 cyclesor8o%SoH after 16 yrs 8o% SoH after 3,650 cyclesOr7o%SOH after 15 years 66.5% SoH after 7,300 cycles Or70%SoH after zo years 8o% SoH after 3,650 cycles Or70%SoH after 15 yrs 66.5%SoH after 7,300 cycles Or70%SoH after 20 years Weight Jibs / kg] 42,i25 / 19,to8 90,500 / 41,050 126,455 / 57,36o Dimensions 19'10.2" L x 8'w x 9'6"H 40'Lx 8'wx 9'6"H 53 Lx 8'wx9'6"H Enclosure Type / Rating 150 HC / NEMA3 / IP54 Ambient Temperature Range -10 to +50 °c Number of Stacks 6 14 20 Energy Density [kWh /W2] 7.73 1 8.08 9.15 8.95 936 9-65 10.09 Fire Suppression Included with Fire Suppression Agent, Fire Detection Panels with Sensors, Pull Handle, and Lights, and FDC dry standpipe connection Cooling Dual Redundant Forced Air HVAC with Thermostat, Humidity Control, & Economizer OC Collection, Cable Tray, AC Load Panel Included Code and Standards Compliance UL1973, UL9540A, IEC62619, NFPAS55, IS01496-1 *Usable energy for fully populated container; Actual usable energy varies by use case and DC topology; Contact Powin for an accurate estimate ABOUT POWIN ENERGY Powin Energy is creating the next wave of safe and scalable battery energy storage that is purpose-built for the demands of utility -scale, commercial and industrial, and microgrid applications. With an unrivaled team of experts from across the energy industry, almost three decades of supply chain management expertise, extensive battery management software proficiency, a modular architecture, and a streamlined installation processes, Powin is making energy storage highly cost-effective and relatively pain free.