HomeMy WebLinkAboutSDP202000073 Review Comments Minor Amendment 2021-01-08County of Albemarle
Department of Community Development
401 McIntire Road,
Charlottesville, VA, 22902
434-296-5832
Memorandum
To: Andrew Allison
From: Christopher Perez, Senior Planner
Division: Planning
Date: January 8, 2021
Subiect: SDP202000073 Keswick Hall SPA - Minor Site Plan Amendment
The County of Albemarle Planning Division will recommend approval of the plan referenced above once the following
comments have been satisfactorily addressed (The following comments are those that have been identified at this time.
Additional comments or conditions may be added or eliminated based on further review.): [Each comment is preceded by
the applicable reference, which is to the Subdivision/Zoning Ordinances unless otherwise specified.]
1. [SP2018-1] Condition 43. VDH approval is required. Review comments are pending to be forwarded once received.
2. 132.7.4.1, 32.7.4.21 Prior to site plan approval a WO plan amendment is required.
3. 132.5.21 Revise the site plan number on the cover sheet to SDP2020-73.
4. 132.5.2(n), 32.6.2(a)] Dimension and label the dumpster area, including the dumpster pad dimensions.
5. 14.12.131 Load Areas. Dimension and label the loading area.
6. 132.5.2(n), 4.17.41 Lighting. Provide lighting cut sheets of all the proposed fixtures.
7. 132.4.3.6, 32.4.3.21 The site plan shall not be approved until all reviewers have approved the plan. Their comments are
referenced below and attached.
Engineering — John Anderson
Comments attached
Building Official — Michael Dellinger
No objection
Fire and Rescue - Shawn Maddox
No objection
Virginia Department of Health (VDH) — Josh Kirtley
Comments pending to be forwarded once received.
Staff has provided references to provisions of Chapter 18 of the Code of the County of Albemarle. The Code is kept up to
date by the County Attorney's office. The Code may found on the County Attorney's website which may be found under
"Departments and Services" at Albemarle.org. In accord with the provisions of Section 32.4.3.5 of Chapter 18 of the Code
if the developer fails to submit a revised final site plan to address all of the requirements within six (6) months after the date
of this letter the application shall be deemed to have been voluntarily withdrawn by the developer. If you have any
questions about the comments please feel free to contact me.
Please contact Christopher Perez in the Planning Division by using coerez e albemarle.org or 434-296-5832 ext. 3443 for
further information.
Review Comments for SDP202000073 MinorAmendment
Project Name KESWICK HALL SPA- MINOR - DIGITAL
Date Completed: Friday, November 20, 2020 Department/Division/Agency: Review Status:
Reviewer John Anderson
CDD Engineering Requested Changes
1. C0.0: Revise Stormwater Nutrient Credits Note to reference 0.09 Ib./yr. surplus nutrient credits, consistent with
WPO201800078 Amendment #2
2. C0.0: Please revise Stormwater Nutrient Credits Note to reference WPO201800078 Amendment #2 sheet C6.0, dated
11-9-2020.
3. C4.0, C5.0: Provide CG-6 along lower edge of pavement of spa access, rather than CG-2. Curb with gutter is required
per 18-4.12.15.g. The lower edge of spa site access concentrates runoff, which is then conveyed to storm structure inlets 118
and 120.
4. Provide CG-6 where curb exists fronting the 3 (typ.) parking and 2 HC parking spaces (runoff is conveyed to Str. 116).
Also, review item 3, above.
5. C5.0: Reinforced turf pavers grading concentrates runoff along east edge of pavers for -200' over a 5' vent. interval.
Engineering recommends consider permanent measure at lower end of pavers to distribute this east edge concentrated flow.
Proposed grading virtually assures problems at this location, over time, especially during or after less frequent storm events
which will not have time to infiltrate pavers, but will behave more nearly as runoff from a fully impervious surface, with
concentrated runoff along the east edge likely to cause erosion. A shift in design now may help avoid remediation effort, later.
6. C7.1: Recommend revise 8" dome grate (increase size) to limit 6.593' spread at this location, given proximity to road
and sidewalk. 6.6' spread at this location is, however, permissible.
7. C7.1: Please ensure storm line profiles are consistent with WPO201800078 Amendment #2, d. 11/9/20
Page: 1 County of Albemarle Printed On: 01/08/2021
Review Comments for SDP202000073 MinorAmendment
Project Name KESWICK HALL SPA- MINOR - DIGITAL
Date Completed: Wednesday, December 02, 2020 Department/Division/Agency: Review Status:
Reviewer Betty Slough 1 CDD Inspections No Objection
Pape: 10 County of Albemarle Printed Cn: o1f118l21121
Review Comments for SDP2O2OOOO73 MinorAmendment
Project Name KESWICK HALL SPA- MINOR - DIGITAL
Date Completed: Sunday, November 29, 2020 Department/Division/Agency: Review Status:
Reviewer: Shawn Maddox Fire Rescue i- No Objection
Page: 10 County of Albemarle Printed On: r0110812021