Loading...
HomeMy WebLinkAboutSUB202000223 Review Comments Preliminary Plat 2021-01-29�,t Or Al� ��RCIN�P COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 229024596 Phone (434) 296-5832 Fax (434) 972-4126 January 29, 2021 Bethany Velasquez Roudabush, Gale & Associates 999 2"' St. SE, Suite 201 Charlottesville, VA 22902 bethanygroudabush.com RE: SUB202000223 Dunlora Farm Subdivision - Preliminary Subdivision Plat Dear Ms. Velasquez: The Site Review Committee has reviewed the development proposal referenced above. Initial comments from the following divisions of the Department of Community Development and other agencies, as applicable, are attached: Albemarle County Planning Services (Planner) Albemarle County Engineering Services (Engineer) Albemarle County Information Services (E911) Albemarle County Building Inspections Albemarle County Department of Fire Rescue Albemarle County Service Authority Rivanna Water and Sewer Authority Virginia Department of Transportation Virginia Department of Health Comments reflect information available at the time the development proposal was reviewed, and should not be considered final. However, the Site Review Committee has attempted to identify all issues that will be required to be resolved prior to Final Site Plan approval. The applicant shall request the project be deferred to allow required revisions if required. Please contact me at your earliest convenience if you have questions or require additional information. Sincerely, L N` w Cameron Langille Senior Planner II CC: Keith Lancaster Southern Development klancaster(c�r�,southem-development.com Albemarle County Planning Services (Planner) — Cameron Langille, blangille@albemarle.org — Required changes prior to preliminary plat approval: 1. [14-218] Total fees for the preliminary plat include $1,236.00 review fee + $75.00 Fire Rescue fee + $215.00 mailed notice fee = $1,526.00 total. County records show that $1,311.00 has been paid for this application. Please submit payment for the remaining $215.00 prior to the action deadline for this application (Friday, February 5, 2021). 2. [14-400] Please add a note stating what type of subdivision this is. Per Section 18-15.3, the minimum permitted lot size for standard level conventional subdivisions in the R4 district is 10,890 sq. ft. The minimum permitted lot size for bonus level conventional subdivisions is 7,260 sq. ft. There are lots as small as 1,700 sq. ft. proposed. The only subdivision types with no minimum lot sizes are standard level cluster developments, and bonus level cluster developments. Which subdivision type is proposed here? a. Since the lots sizes proposed can only be allowed through either a standard level cluster development or bonus level cluster development, state which type is proposed. b. Based on whatever development type is proposed, state the maximum permitted density. Standard level cluster developments have a maximum permitted density of 4 du/acre. Bonus level cluster developments have a maximum permitted density of 6 du/acre. c. State the maximum proposed density in a note. d. Per Section 18-2.2, cluster developments (both standard level and bonus level) must have a minimum of 25% open space. Add a note stating the minimum acreage of open space required, and the proposed acreage/percent of open space proposed. 3. [14-316, , 14-403, 14-409, 14-410] This plat shows two street connections to adjacent parcels, TMP 06200-00- 00-016DO and TMP 062A3-00-00-OO1130. Those parcels are within the limits of the Belvedere development. However, no streets have been created in either parcel. Please see comments from Albemarle County Fire & Rescue and the Virginia Department of Transportation (VDOT) for additional information. Please address the following: a. [14-316,14-410 (F), 14-403] The principal means of access to new subdivisions shall either be a public or private street. There are no existing streets or right-of-way located on the adjacent parcels where interconnections (Fowler Street and Adam Street) are proposed to provide access to the subdivision. The plat will be denied unless an application (road plan and right-of-way plat) are submitted that identify how the Dunlora Farm subdivision will connect to public streets on TMP 62-16D. 4. [14-410] Please see Fire & Rescue comments #2 and #4. The plat must be revised as follows: a. Revise cul-de-sac diameters so that they are 96' in width. b. Please confirm that the proposed street widths comply with the dimensions specified in Fire Rescue comment #4. 5. [14-302 (A)(12)] Please see attached Engineering comments (#1-7) regarding the topography exhibit in relation to Preserved Steep Slopes. In order to comply with applicable State and County regulations, the steep slopes exhibits must be revised so they are sealed by a licensed land surveyor in order to use LiDAR (currently shown) to establish true topography on site. 6. [14-302 (13)(1)] Please add a date of last revision. Comment to be addressed prior to final plat approval: 7. [General Comment] Road plan approval will be required prior to final plat approval. Prior to final plat approval, the private street will need to either be built or bonded. 8. [General Comment] Final plat must demonstrate compliance with all applicable Subdivision Ordinance requirements prior to approval. This includes all applicable Sections of 14-303, 14-302 through 14-312, 14-314, 14-316, 14-317, 14-318, and 14-400 through 14-441. 9. [14-302 (A)(3) & 14-302 (A)(4)] Please show the existing "non-exclusive right-of-way" described in DB 4299 page 58. This is not shown on the plat. Is this a private easement? Based on the recorded instrument referenced I this comment, this appears to be a private access easement. However, staff cannot find a plat that shows the locations of the easement. Please provide documentation as to whether this easement/ROW still exists, who owns it, and explain what the intent is for it. Will it be extinguished? 10. [14-302 (A)(4)] Please revise labels for all proposed private easements so that they state the easement dimensions. 11. [14-302 (A)(5)] Please show the location and dimensions of all existing and proposed public easements outside of a street right-of-way. Existing easements shall be labeled with the deed book and page number and the name of the public owner of record. Proposed easements shall be labeled as "dedicated to public use." 12. [14-302 (A)(8)] Please provide a table or note that specifies the number of single-family detached and single- family attached lots. a. Additionally, lot numbers are missing from some of the proposed single-family detached lots along Fowler Street. Please revise so that all lots have a lot number and their dimensions and acreages are stated. 13. [14-302 (A)(14)] Add a note to the plat stating who will own and maintain all private open space areas. 14. [14-302 (A)(15)] Please state the names and addresses of any easement holders that affect the properties as a note on the final plat. 15. [14-302 (B)(10)] Revise the WPO stream buffer labels so that it states "Water Protection Ordinance Stream Buffer." a. Add a note to the plat stating "The stream buffer(s) shown hereon shall be managed in accordance with the Albemarle County Water Protection Ordinance." 16. [14-303 (A)] On the final plat, please add a statement of consent to division as follows: "The platting or dedication of the following described land [insert a correct description of the land subdivided] is with the free consent and in accordance with the desire of the undersigned owners, proprietors and trustees, if any." 17. [14-303 (C)] Provide The exterior boundary lines of the property with bearings in degrees, minutes and seconds. Curvilinear data shall include radius, central angle, arc length, and tangent distance. All dimensions shall conform to the standards set forth in this chapter. 18. [14-303 (D)] Clearly state the total acreage of each existing lot and each proposed lot. 19. [14-303 (E)] All linear, angular, and curvilinear dimensions of lots, streets, alleys, public easements and private easements and shared driveways shall conform to the requirements set forth in 8 VAC 10-20-370(C), a copy of which shall be on file in the department of community development. Curvilinear data shall include radius, central angle, arc length, and tangent distances and may be shown either directly on the corresponding boundary or surveyed line or in table form. Easements shown for private streets, alleys and shared driveways shall be labeled as "private street easement', "alley easement' or "shared driveway easement." The easement holder(s) shall be identified on the plat. If shared driveways are shown, a note shall be added to the plat stating that maintenance shall be by the owners of the lots affected by the shared driveway easement, not by the Virginia Department of Transportation or the county. 20. [14-303 (G)] Please state who will own all common areas (private open space, private streets, etc.) within the development. 21. [14-303 (H)] Identify the location and material of all permanent reference monuments. 22. [14-303 (1)] Provide a definite bearing and distance tie between not less than two (2) permanent monuments on the exterior boundary of the property and further tie to existing street intersection where possible and reasonably convenient. 23. [14-303 (L)] Identify the location and dimensions of each public utility, drainage and sight distance easement outside of a street right-of-way; for each existing easement, include a note stating the deed book and page number. 24. [14-303 (M)l The name of each proposed street, which names shall be subject to approval by the agent. See E911 comments for more information. 25. [14-303 (0)] On the first sheet, add signature panels for each owner and for the agent or his designee. The signature panel for the owner shall be located immediately below the statement required by Section 14-303 (A) 26. [14-303 (P)] Add notary panels for the notary to acknowledge the signature of the owner. 27. [14-303 (Q)] Add a note stating that the properties will be served by the public water and sewer system. 28. [14-303 (S)] Provide at least four (4) control points, evenly distributed across the property and located at survey property comers, and shown on each sheet depicting the property. 29. [14-317] Prior to final plat approval, an instrument evidencing maintenance of all require improvements (open space lots, private easements, etc.) must be submitted and reviewed to ensure compliance all applicable sub- sections of Section 14-317. 30. [14-409] Prior to final plat approval, the plat must be revised so that at least one of the following streets is extended and coordinated to the abutting property line of TMP 62-16C: Fowler Street, Tazewell Drive, or Tarlton Street. 31. [14-418] Please show how the proposed emergency access road will connect to the street it will serve (Fire & Rescue comment #1). Please contact Cameron Langille at the Department of Community Development at blanig Ile@albemarle.org or 296- 5832 ext. 3432 for further information. Comments from Other Reviewers: Albemarle County Engineering Services (Engineer) — John Anderson, 4anderson2@albemarle.org — Required changes, see attached. Albemarle County Information Services (E911) — Brian Becker, bbeckeranalbemarle.org — Required changes, see attached. Albemarle County Historic Preservation — Margaret Maliszewski, mmaliszewskianalbemarle.org — Requested changes, see attached. Albemarle County Building Inspections — Michael Dellinger, mdellinger@albemarle.org — Required changes, see attached. Albemarle County Department of Fire Rescue — Shawn Maddox, smaddoxkalbemarle.org — Required changes, see attached. Albemarle County Service Authority — Richard Nelson, melson@serviceauthority.org — Approved with conditions, see attached. Rivanna Water and Sewer Authority— Victoria Fort, vfort@rivanna.org 434-977-2970, ext. 205 — Requested changes, see attached. Virginia Department of Transportation — Max Greene, max. greene n&vdot.vir ig nia.gov — Required changes, see attached. Virginia Department of Health — Alan Mazurowski, alan.mazurowski@vdh.vir ig nia.gov - No objection, see attached. � AI �h �lRGIN�P COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902-4596 Phone (434) 296-5832 Fax (434) 972-4126 Subdivision Plan Review Project title: Dunlom Farm Subdivision Preliminary Plat Project file number: SUB2020-00223 Plan preparer: Bethany Velasquez, Roudabush, Gale and Assoc. 999 Second St. SE, Charlottesville, VA 22902 bethanv(d�roudabush.com Owner or rep.: Phillips E L and Ann P Phillips, Living Trust, et al, c/o Caroline Molina -Ray 6704 Menchaca Road, Unit 33, Austin, TX 78745 Developer: Keith Lancaster, Southern Development / 142 S. Pantops Drive Charlottesville, VA 22911 [ klancaster(i�southem-develooment.com ] Plan received date: 17 Dec 2020 Date of comments: 28 Jan 2021 Plan Coordinator: Cameron Langille Reviewer: John Anderson SUB2020-00223 V1 1. VGIN LIDAR is acceptable source of topography. Please provide date of photometric data. 2. VGIN LIDAR data is acceptable source of exhibit topography, with LS-seal on Steep Slopes Exhibit. 3. Any sheet that shows existing topography and physical improvements must be sealed by a licensed land surveyor if VGIN LIDAR data is basis of existing or proposed topography. 4. Note: Please see email to RGA, 1/27/2021 11:13 AM, which outlines county interpretation re. use of LiDAR data as source of topography for any design that shows physical improvements. Also, § 54.1-402, Code of Virginia. 5. Please edit title of Critical Slopes Exhibit to Steep Slopes Exhibit since project is in the development area. 6. Please also ensure all numeric -text information on each sheet of Steep Slopes exhibit is readable, % slope for shaded (steep slopes) or unshaded (removed) areas, for example. 7. Please revise Note 9. to clarify that proposed grading shown on preliminary plat sheets occurs only in areas shown by VGIN LIDAR (or physical survey) to be less than 25% grade, since grading cannot occur on steep slope areas (>_ 25% slopes), except for SWM facility outfall/s. 8. Please revise Note 4 to reference May 16, 2016 (Floodplain Eff. Date, 18-30.3.2.) V2 9. Show FEMA horizontal limits of floodplain continuous, unobscured by steep slopes shading. ■niu "-'wa sR Engineering Review Comments Page 2 of 6 10. Recommend remove lot 26 from horizontal limits of floodplain (blue circle, image, below). 11. Provide copy of recorded Retaining Wall Maintenance Agreement for any wall that spans lot lines, Lots 22-23, 3-4, 6-9, 150-151, 78-80 (and 82), and Lots 11-13, for example. Albemarle is not party to these Agreements but needs deed bk.-pg. reference to recorded Retaining Wall Maintenance Agreements between owners of affected lots. 12. Provide additional existing contour labels near proposed grading /dwellings, Lots 11-30, to aid review. 13. Revise `Private SWM Facility Easement' to `Public SWM Facility Easement.' 14. Please ensure subsequent WPO and ROAD Plans show runoff from Odom Ct., a public road, routed to SWM facility (preliminary plat shows this via proposed storm line within easement between Lots 13-14), this SWM facility appears to discharge across preserved slopes. The only by -right construction of a SWM facility outfall across preserved steep slopes is if a SWM facility is a necessary, public facility, which it is if it receives /treats runoff from Odom Court. (Ref. 18-30.7.4.b.I.e.) 15. Revise `private drainage easement' label (Lots 13, 14) to read `public drainage easement.' 16. Submit WPO and ROAD Plan and Floodplain Development Permit (FDP) applications at earliest convenience. 17. Notes: a. Steep Slopes Exhibit approval is required prior to/with Preliminary Plat approval since the steep slopes exhibit proposes to remove critical areas proposed to be developed from the steep slopes overlay district based on UDAR /photometric survey data. b. Please see email sent to RGA on topic of slopes /LiDAR (January 22, 2021 3:35 PM, 1/27/2021 11:13 AM). c. FDP review /approval is required prior to WPO plan approval. (link to FDP Application: hfti)s://www.albemarle.org/home/Showpublisheddocument?id=176 d. Slopes exhibit approval is required prior to WPO plan approval, since SWM facility outfall crosses preserved steep slopes. e. ROAD Plan and WPO plan approval are required prior to Final Plat approval. f. With WPO, provide detail sufficient to demonstrate compliance with state SWM quality /quantity requirements. g. A deed of dedication of public drainage easement and separate deed of dedication of public SWM facility are required to be recorded with the final subdivision plat. h. A WPO plan bond is required to receive a Grading Permit. i. Roads must be built or bonded prior to final subdivision plat approval. j. Retaining walls higher than 3' require a building permit. k. Retaining walls higher than 4' require sealed plans. Engineering Review Comments Page 3 of 6 1. Submit sealed retaining wall plan to Engineering for review prior to/with ROAD plan or WPO plan (or at earliest convenience). m. Engineering review of retaining wall plans is separate from county building inspections review of retaining wall plans. 18. SWM, East of intersection of Fowler Street and Goldsbeny Lane: Clarify with revised preliminary plat how proposed grading with significant vertical interval works with proposed SWM. Identify type of SWM facility proposed to be constructed within proposed private SWM facility easement. 19. Please revise Private SWMfacility easement label (last comment) to read Public SWM facility easement. 20. Engineering has general concerns that proposed development, including physical improvements (retaining walls, residential units, SWM facilities, grades), occurs in close proximity to preserved steep slopes. 21. Once Steep Slopes Exhibit approved, revise steep slopes across all sheets to: preserve current steep slope overlay boundaries (indicate with line-type/labels), indicate areas of former steep slopes overlay (areas removed from steep slopes, no shading), and show steep slopes which persist steeper than 25%. Shade persistent steep slopes. Please call if any questions. Goal is to eliminate ambiguity: preliminary plat does not approve development across revised steep slopes. 22. RETAINING WALLS: Please review standards at 18-4.3.3.A. when designing retaining walls. 23. Cuts and Fills: Please review /ref. standards at 18-4.3.3.B. 24. Reverse slope benches /diversion: Please review 18-4.3.3.C. 25. Fire Access Road does not connect with Adams Street. Please clarify design intent. 26. Please ensure revised preliminary plat meets 18-30.3 requirements for permissible use or activity within mapped floodplain. 27. Revise Floodzone Note to reference May 16, 2016 (FIRM), rather than Feb. 04, 2005. (see 18-30.3.2) 28. Check that shaded preserved and managed steep slopes exclude areas shown to be flatter than 25%, per RGA Dunlora Farms Subdivision Critical Slopes Exhibit, dated 12/2/20, submitted with preliminary plat. 29. Ensure revised preliminary plat meets 18-30.3 requirements for permissible use or activity within mapped floodplain. V3 30. Label floodway if floodway linework displays on this sheet. V4 31. Please revise private drainage and private SWM facility easement labels to reference public drainage and public SWM facility easements. V5 32. Remove retaining wall, Lot 165, from limits of mapped floodplain. 33. Tarlton Street storm pipe (behind Lot 173) must be revised to direct discharge perpendicular to grade. Additional comments possible with WPO /ROAD (drainage) plan review. 34. It appears surface storm runoff may cross 3 or more lots, in one or more locations. Please note drainage plan review checklist requirement: provisions and easements for drainage across 3 or more lots. Dense development where fencing, decking, etc is expected should provide yard inlets and pipes in easements, rather than ditches {Policy} V3-V5 35. `W' (ACSA waterline) does not display, please increase pitch of abbreviation with revised preliminary plat, so visible. 36. Additional comments relating to roadway likely with ROAD Plan. For example: Miranda Drive appears to provide right -of way F beyond sidewalk on south side of road, but appears coincident with edge of walk on north side of road. Engineering requests public right-of-way extend F beyond sidewalks throughout the development to allow future VDOT maintenance of sidewalks without encroaching on individual lots. Engineering Review Comments Page 4 of 6 37. Please revise any label reading private drainage easement to read public drainage easement if storm system conveys runoff from a public road, whether runoff is routed to a SWM facility or not. 38. Floodplain, horizontal limits BFE: Although detail will be presented with the FDP Application, additional detail is requested to be shown with the preliminary plat at this location. Show BFEs for Rivanna River, as floodplain transits development parcel. Recommend overlay VFRIS FEMA FIRM floodway BFE data across plan sheets. Please carefully review VFRIS BFE data (355', 354') against VGIN LIDAR data. Sec. 30.3.13- Encroachment standards; determining impact on base Flood elevation. Any use, structure or other development authorized by section 30.3.11 shall be subject to the following: A. Within the floodwayin ZoneA1-30 orAE. The following shall apply within the regulatory flootlway of any 1-3oor AE: 1. Encroachmentprohibited unless owner demonstrates no increase in water surface elevation ofth ase flood. 39. Engineering Review Comments Page 5 of 6 Floodplain shaded blue with horizontal hatching; parcel outlined in yellow. (Albemarle County GIS — Critical Resource Map layer) Wy lOWn EI ti '... r Engineering Review Comments Page 6 of 6 Please feel free to call if any questions. Thank you I Anderson 434.296-5832 -x3069 SUB202000223 Dunlora Farm Subdivision prelim 012821 Review Comments for SUB202000223 Preliminary Plat Project Name: DUNLORA FARM SUBDIVISION - PRELIMINARY - DIGITAL Date Completed: Saturday, January 23, 2021 Department/DivisiordAgency: Review Status: Reviewer: Brian Becker CDD E911 Requested changes Critical Issues: Adams St. is not an acceptable name. Comments: The Albemarle County Road Naming and Property Numbering Ordinance and Manual does not permit approval of a road name that duplicates an existing road name, unless the road name is a dead-end street originating off the original road. Unfortunately, Adams Cf. is an existing road name in the County and Adams St. does not originate off it. Please provide an alternate road names for review. Odom Ct, Gokisberry Ln, Tarlton St, Tarlton Alley, Miranda Ave, Tazewell Dr and Diggs Dr will all be placed on the Albemarle County Reserved Road Name list. Resources A PDF version of the Ordinance and Manual can be found here: https://g isweb. alt)emarle.org/g isdata/Road_Naming_and_Property_Numbering_Ordi nan ce_and_Manual. pdf Albemarle County Master Road Names Directory: https://tfwab.abemade.org/Forrns/RoadNameindex Page: 1� County of Albemarle Printed On: 01 /25/20 11 Review Comments for SUB202000223 Preliminary Plat Project Name: DUNLORA FARM SUBDIVISION - PRELIMINARY - DIGITAL Date Completed: Thursday, January 21, 2021 Department/DivisiordAgency: Review Status: Reviewer: Betty Slough CDD Insoactions see Recommendations Add the following note to the general notes page: Retaining walls greater than 3 feet in height require a separate building permit. Walls exceeding 4 feet in height require a stamped engineered design also. Walls require inspections as outlined in the USBC. Add the following note to the general notes page: ALL water lines, sewer lines, and fire lines from the main to the structure located on private property MUST have a visual inspection performed by the building department. Add the following note to the general notes page: Where the flood level rims of plumbing fixtures are below the elevation of the manhole cover of the next upstream manhole in the public sewer, the fixtures shall be protected by a backwater valve installed in the building drain, branch of the building drain or horizontal branch serving such fixtures. Plumbing fixtures having flood level rims above the elevation of the manhole cover of the next upstream manhole in the public sewer shall not discharge through a backwater valve. Add the following to the general notes page: All roof drains shall discharge in a manner not to cause a public nuisance and not over sidewalks. Note to developer: Due to required distances from lot lines and structures as required by the NFPA, underground propane tanks may be prohibited. Plan accordingly. Page: 1� County of Albemarle Printed On: 01 /25/20 11 Review Comments for SUB202000223 Preliminary Plat Project Name: DUNLORA FARM SUBDIVISION - PRELIMINARY - DIGITAL Date Completed: Monday, January 2 , 2021 Department/DivisiordAgency: Review Status: Reviewer: Shawn Maddox Fire Rescue Requested Changes 1. 1 cannot see on the plans where the emergency access road connects to the streets it serves. 2. All cul-de-sac must be 96' diameter. None of the cul-de-sacs shown appear to meet the minimum standard. 3. Please provide the dimensions of the turn around provided on Odom Court. 4. To ensure adequate street width for all streets and alleys that serve as the primary means of access to a structure please confirm that this plat will allow compliance with: - No on street parking - >29 clear travel width. - Parking on one side - >28' but less than 36' clear travel width. - Parking on both sides - >36' clear travel width. Pager County of Albemarle Printed On: 01 /25/20 11 Review Comments for SUB202000223 Preliminary Plat Project Name: DUNLORA FARM SUBDIVISION - PRELIMINARY - DIGITAL Date Completed: Wednesday, December 16, 2020 Department/DivisiordAgency: Review Status: Reviewer: Margaret Maliszewski —3 CDD ARB see Recommendations Pager County of Albemarle Printed On: 01 /25/2021 Review Comments for SUB202000223 Preliminary Plat Project Name: DUNLORA FARM SUBDIVISION - PRELIMINARY - DIGITAL Date Completed: Wednesday, January 20, 2021 DepartmenUDivision/Agency: Review Status: Reviewer: Richard Nelson Ell ACSA see Recommendations I recommend this plat for approval with the following conditions, Submit 3 copies of the utility plan and water/sewer data sheets to ACSA for review and approval. A RWSA sewer capacity certification will be required. RWSA will need to review and approve the sewer connection to the RWSA manhole. ACSA will need to review the available sewer capacity along the Dunbra trunk sewer to confirm there is adequate capacity. Provide the proposed sewer flows that will be entering the existing ACSA owned sewer main for review. Thanks, Richard Nelson Civil Engineer Albemarle County Service Authority 168 Spotnap Road Charlottesville, Virginia 22911 (434)977-4511 Page: 1--1 County of Albemarle Printed On: 01 /25/2021 (Z) COMMONWEALTH of VIRGINIA DEPARTMENT OF TRANSPORTATION Stephen C. Brich, P.E. 1401 East Broad Street (804) 786-2701 Commissioner Richmond, Virginia 23219 Fax: (804) 786,2940 January 14, 2021 Cameron Langille County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Re: SUB-2020-00223- Dunlora Farm Subdivision — PP Dear Mr. Langille: The Department of Transportation, Charlottesville Residency Transportation and Land Use Section, has reviewed the above referenced Glenbrook at Foothill Crossing Phase IIB — Preliminary Plat, as submitted by Roudabush, Gale & Assoc., Inc., dated December 7, 2020 and find the following: 1. The proposed plat does not appear to connect to VDOT R/W at this time. Please show how the roadways will be connected. 2. Approved road plans meeting SSAR, and in compliance with the VDOT Road Design Manual are required prior to final plat approval. 3. Sight lines location of eye do not appear to be per RDM F-40 Intersection Sight Distance detail and table 2-5 and RDM B(1)19 Sight Distance. Eye location will be a minimum 14.5 feet from the edge of travel lane. 4. Please include a note stating the homeowners and/or homeowners association shall be responsible for keeping the variable sight distance easements clear from obstruction at all times for public safety. 5. 'There must be a 40' buffer between the cul-de-sac and parallel parking. 6. Recommend bump -outs for parking per AASHTO Green Book 2011— 4.20 On -Street Parking. 7. Please include a note stating that VDOT will only maintain within drainage easements to the extent necessary to protect the roadway from flooding or damage. VirginiaDOT.org WE KEEP VIRGINIA MOVING 8. Pavement designs need to be in accordance with the Pavement Design Guide for Subdivisions and Secondary Roads, 2018 edition. h"://www.virginiadot.orwbusiness/resources/Materials/Pavement Design Guide for S ubdivision_and _Secondarv_Roads.pdf 9. Note that the final plan must show conformance with the VDOT Road Design Manual Appendices B(1) and F, as well as any other applicable standards, regulations or other requirements. A VDOT Land Use Permit will be required prior to any work within the right of way. The owner/developer must contact the Charlottesville Residency land Use Section at (434) 422-9399 for information pertaining to this process. If you have further questions please contact Max Greene at (434) 422-9894. Sincerely, Adam J. Moore, P.E. Area Land Use Engineer Charlottesville Residency Review Comments for SUB202000223 Preliminary Plat Project Name: DUNLORA FARM SUBDIVISION - PRELIMINARY - DIGITAL Date Completed: Thursday, January 14, 2021 Department/DivisiordAgency: Review Status: Reviewer Victoria Fort —2 RWSA Requested Changes RwJA nas reviewed me uunlora Farm zsummsIOn PreOminary Plat dated 1 z/i/LULU ny Rouaanusn, Gale 15 ASSO., Inc. and has the following comments. Sheet V3: 1. RWSA would like to request an access easement following the ACSA sanitary sewer easement from the MH48 being tied into to the cul-de-sac. 2. The sewer is deep about 12' at least and has a liner that must be repaired when connecting to our Manhole- 3- When tying into the manhole observe the stairs inside the manhole and do not make a connection into the stairs. 4. Please attach the following on your plans, does not have to go on the plat. Sewer Connection Add the following note to the utility plan sheet: All connections to RWSA manholes shall be watertight and made with a flexible rubber boot. All coring methods, the coring contractor and all materials for construction shall be approved by RWSA in writing prior to construction. RWSA Engineering Staff shall be present for all cores into the manholes. Bypass pumping may be required at the sole discretion of RWSA staff. Grouting of the manhole bench or interior may be required, at the sole discretion of RWSA staff, for a smooth transition of flow. Existing manholes shall be backfrlled to original grade to the satisfaction of RWSA. Contact RWSA Engineering a minimum of 3 business days in advance to schedule a core of a manhole. If manhole is lined, add the following note in addition to those above: Existing RWSA manhole RVI-MH48 has a protectwe HDPE liner (Agru Sure Grip). Any modifications or damage caused to the liner must be repaired by a contractor that is approved by the manufacturer using the lining manufacturer's recommended method. The repair method and contractor must be approved by RWSA in writing. Let me know if you have any questions. Thanks, Dyon Vega Civil Engineer Pager County of Albemarle Printed On: 01 /25/2021 COMMONWEALTH of VIRGINIA In Cooperation with the Thomas Jefferson Health District ALBEMARLE CHARLOTTESVILLE State Department of Health FLUVANNACOUNTY (PALMYRA) 1138 Rose Hill Drive GREENE COUNTY (STANARDSVILLE) LOUISA COUNTY LOUISA) Phone (434) 972-6219 P 0. Box 7546 NELSON COUNTY ILOVINGSTON) Fax (434) 972-4310 Charlottesville, Virginia 22906 January 20, 2021 Cameron Langille, Senior Planner II Albemarle County Community Development 401 McIntire Road Charlottesville, VA 22902 RE: Dunlora Farm Subdivision Preliminary Plat TM#: 62-16A SUB2020-223 Mr. Langille: As requested, I've reviewed the subject plan, dated 12n120, the Albemarle County GIS database, as well as VDH records on file. It appears there are no existing onsite septic systems or wells associated with this parcel, and all new construction will be connected to public sewer & water systems. Therefore, I have no concerns or objections to the preliminary plat. If there are any questions or concerns, please give me a call, 434-972-4306. Sincerely, Alan Mazurowski Environmental Health Supervisor Thomas Jefferson Health District alan.mazurowski(a�vdh.vir ig nia.gov