Loading...
HomeMy WebLinkAboutWPO200600061 Review Comments 2007-03-23�pF A vt�r�1Q COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 Project: Avemore Connector Road (WP0200600061) Plan preparer: WW Associates [fax 978 -1444 email cratkovich @wwassociates.net] Owner or rep.: Chris Schooley [fax 975 -3542 email ccchooley @stonehaus.net] Date: 23 Mar 2007 Dear Sirs, The Avemore Connector Road Plans and Erosion & Sediment Control Plans (WP0200600061) were previously approved by the County. However, we have erred and should not have yet approved the plans. I apologize for this. A stormwater management ammendment has not been reviewed or approved for this project, and must be approved before the E &S plans can be approved or a grading permit can be obtained. An adequate stormwater management amendment serving the connector road and Fontana is necessary, as a detention basin serving Fontana is proposed to be removed. It appears that detention could be met by routing stormwater to the Luxor Pond #2 across Olympia Drive. Stormwater Management will also need to be provided for the proposed connector road. Once again, I apologize for overlooking the necessary Stormwater Plans. We will do our best to work quickly with you to correct this issue. Sincerely, Jonathan Sharp Civil Engineer Albemarle County Phone: (434) 296 -5832 ex. 3025 Email: jsharp @albemarle.org Glenn Brooks County Engineer Albemarle County Phone: (434) 296 -5832 ex. 3273 Email: gbrooks @albemarle.org David M. Jensen, PE Project Engineer WW Associates 1402 Greenbrier Place Charlottesville, VA 22901 April 13, 2007 Plan Review of Filterra Avemore Connector Road, Albemarle County Dear Sirs filleffa Thank you for submitting the partial plans (04- 09 -07) for our review of the Avemore Connector Road project. Filterra® structures 6A, (8'x4') and 7A,(8'x4') were studied for; • Planned Filterra® box size • Filterra® contributing drainage area meeting project's regional sizing specification • Spot elevations (TC) for Filterra® and bypass relief • Filterra® invert elevations are 3.5' below TC • The bypass is lower than the Filterra® elevation (spot elevations) • The grading pattern encourages cross linear flow and not head -on flow • The Filterra® outlet drain pipe is sized correctly and exits perpendicular to the wall • For any conflicting structures such as storm drain pipes below Filterra® • For most efficient placement of Filterra® units • 4 -6" opening throat detail and standard notes on plans The plan review concluded that the Filterra structures listed above were sited and sized appropriately to treat stormwater to our published specifications. Operational consistency with these specifications is contingent upon the stormwater units being installed correctly and according to the plans, as well as regular maintenance being performed. Installation Help documents will be forwarded to the Buyer at time of order. The Filterra Installation, Operation and Maintenance Manual will be forwarded to the Owner when the units are activated by Americast. Yours sincerely Edward Kay, Filterra Operations Manager Manufactured by Americast T: (804) 798 -6068 *MERIQI�07 11352 Virginia Precast Road F: (804) 752 -6838 Ashland, VA 23005 E: design @filterra.com www.filterra.com