HomeMy WebLinkAboutSDP202100001 Correspondence 2021-03-19 (2)608 Preston Avenue P 434.295.5624 Suite 200 IF434.295.1800 T I M M O N S GROUP Charlottesville, VA 22903 www.timmons.com March 19, 2021 Mariah Gleason, Senior Planner County of Albemarle Dept. of Community Dev. 401 McIntire Rd, North Wing Charlottesville, VA 22902 RE: Ivy Proper — Final Site Plan Review — SDP202100001 - Comment Response Letter Dear Ms. Gleason: We have reviewed all of your comments from February 24, 2021 and made the necessary revisions. Please find our responses to the comments below in bold lettering. [32.5.2(a)] Application ID. Final site plan receive unique application numbers, separate from initial site plans. Please include the application numbers for both the final site plan (SDP202 10000 1) and initial site plan (SDP2020000065) for this development on the Cover Sheet. Both site plan numbers are now included on the cover sheet. 2. [32.5.2(i), 32.5.2(m)] Easement Plat. Prior to final site plan approval, any required easements supporting the site plan will need to be reviewed, approved, and recorded. The recorded easements will then need to be located on the site plan with the recorded deed book and page noted. According to the site plan, the plat will need to address the following: a. Private shared access easement for the entrance and parking area (for the benefit of TMP 58A2-20A). A shared use parking agreement and easement plat will be submitted prior to Final Site Plan Approval. b. Drainage easements. Drainage and SWM easements have been added to the plan. c. Private landscaping, construction, and maintenance easements, as necessary. Construction and landscape easement has been added to the plan. d. (Optional) Vacation of property line as shown on the Existing Conditions Sheet. 3. [32.7.9] Landscape Plan. (Note: If there are conflicts between comments made by Planning and ARB, once their review begins, Planning will defer to the ARB as their guidelines are more strict.). ENGINEERING I DESIGN I TECHNOLOGY a. Staff recommends providing the landscape plan as a separate sheet within the site plan. A separate landscape plan is now provided. See sheet L 1.0. b. If existing landscape features will be preserved, as shown on the northern and western portions of the lot, the landscape plan should show — as applicable — the tree area to be preserved, the limits of clearing, the location and type of protective fencing, any grade changes requiring tree wells or walls, and trenching or tunneling proposed beyond the limits of clearing. Also, a signed conservation checklist will be needed in accordance with 32.7.9.4(b). The trees indicated to remain are not counting towards stormwater management or landscape requirements. As such, tree protection fencing has been omitted. c. The Plat Schedule notes 12 Willow Oaks are being provided, however the plan map only shows I I Willow Oaks. Please revise accordingly. The landscape plan has been revised. Planting schedule has been revised to agree with the trees shown graphically in plan view. d. The plan indicates that 8 large trees are being provided along Ivy Road, however the Landscaping Along The Frontage table indicates only 7 large trees are being provided. Please revise accordingly. The landscape plan has been revised and now includes 8 large street trees. e. Please clarify what is being used to calculate the 891 square feet of interior parking lot landscaping area that is being provided by the plan. Additional breakdown of interior parking lot landscaping will be provided. f. The Tree Canopy requirement should be based off the total parcel area, as surveyed, which is 0.87 acres. Please update the Tree Cover Calculations table accordingly. The canopy calculation has been updated accordingly. 4. [32.5.2(n)] Outdoor Lighting. Is there any outdoor lighting proposed for this project? If so, please see Sec. 32.6.2(k) and Sec. 4.17 regarding materials that need to be provided for staff review and minimum performance standards/design requirements, respectively. Also, please keep the character of the surrounding area in mind when developing the light plan. A photometric plan and lighting cut sheets have been included and comply with County Ordinance. S. [32.5.2(n), 32.7.2.3] Sidewalks along streets. Revise the walkway in front of the building to meet VDOT standards. See Sec. 32.7.2.3 for more information. The material of this walk has been revised to be concrete. 6. [32.5.2(n), 4.12.19] Dumpster Pad. Provide details for the proposed dumpster pad that demonstrates that the minimum design requirements contained in Sec. 4.12.19 are being met. The proposed dumpster pad is 20'X 12' which provides 8' of heavy duty concrete outside of the enclosure for garbage truck front wheel loading. 7. [32.5.2(a)] Owner Information. Following the recent sale of the property, update the parcel owner and associated information for the subject properties across all applicable sheets. (Note: This information may need to be updated again when an easement plat is approved and recorded. See Comment 2). The owner information and associated information has been updated for the subject properties. 8. [32.5.2(a)] Zoning Notes. If/when the special exception for the disturbance of critical slope areas is approved, the approval and any conditions thereof will need to be included in the Zoning notes. Acknowledged. 9. [32.5.2(b)] Open Space. As a commercial development, this plan is not required to provide open space. As such, staff advise that the "Proposed Open Space" data under the proposed Use notes be removed. (Note: There is a requirement for a certain amount of tree canopy onsite, which can be met by preserving existing tree areas, however, there is no specific requirement for the provision of "open space", per Sec. 4.7). The open space callout has been removed from the plans. 10. [32.5.2(a), 4.20] Setbacks. Include in the setback notes that the maximum front setback is 30 feet from the right-of-way. The maximum setbacks are now included on the cover sheet site notes. 11. [32.5.2(f)] Water -related notes. a. On the Cover Sheet, please revise the drainage district to explicitly state that the subject property lies within the "Ivy Creek water supply watershed". The drainage district has been revised accordingly. b. Since Little Ivy Creek is not adjacent to this parcel, it does not need to be included in the notes. However, if the applicant desires to leave it on the site plan, staff recommends amending the drainage district notes to state that Little Ivy Creek is located near, but not adjacent to, the site OR 'Y' feet away. The note has been revised to call out the distance Little Ivy Creek is from the site. 12. [32.5.2(d)] Topography. a. Knowing Engineering has requested the Erosion & Sediment sheets be removed from the final site plan, please keep in mind that proposed grading is still a required element of final site plans. Therefore, this information will still need to be included somewhere within the final site plan. Comment noted. The ESC sheets will be removed from the final site plan and the proposed grading will still be included in the submission. b. Show where critical slope areas will remain on the site following any proposed disturbance/construction. A callout for critical slopes to remain has been added to the plans. 13. [32.5.2(n), 32.5.2(r)] Paving materials. Provide a legend for proposed paving materials on the Layout Plan sheet. A paving legend has been added to the layout sheet. 4. [32.5.2(n)] Signs. Identify where parking signs for handicap parking spaces will be placed/posted. Handicap parking signs have been added to the plans and called out. S. [32.5.2(a)] Surrounding parcel information. Provide the zoning district and present uses for TMP 58A2-20A and TMP 58A2-21. Also, please update the owner information for TMP 58A2-21. The surrounding parcel information has been updated as requested. 16. [32.5.2(a), 32.5.2(s)] Labels. a. On the Existing Conditions & Demolition Plan Sheet, please avoid placing labels beneath or in conflict with hatched Iinework. Text overwrites have been updated to avoid conflict. i. Move the curve data for the southern portion of the boundary line along Ivy Road outside of the hatched area. Consider using a leader line, similar to how the other curved boundary line data is provided. The curve data has been relocated as requested. ii. Relocate the critical slopes label. The critical slope labels have been relocated as requested. iii. Move the "Remove Broken Asphalt" label. The label has been moved accordingly. iv. Move the benchmark label. The benchmark label has been moved accordingly. b. Please identify what the solid grey line running roughly along Ivy Proper, but not parallel to the subject property boundary represents. This line can be seen running northwest from the westernmost property corner. A label has been added to help better identify the solid gray line. 17. [32.6.2(h)] Signature panel. Include a signature panel on the Cover Sheet for signature by each member of the site review committee. Staff can provide an example signature panel upon request. A signature panel is now included on the cover sheet. 18. [32.5.2(k)] VDH approval. VDH approval of the private well and septic fields is needed prior to final site plan approval. Acknowledged. This process is underway and approvals will be granted prior to final site plan approval. 19. [Comment] Critical Slopes Waiver. The critical slopes waiver that submitted in association with this final site plan is being processed by staff under SE202100002. County staff will be in contact if additional information is needed to process this waiver request. Comment acknowledged. Albemarle County Engineering Services — David James - Engineer: 1. VSMP plan & application will need to be submitted and approved prior to FSP approval. A VSMP application and WPO has been included with this submittal. 2. A plat will need to be recorded prior to FSP approval. Acknowledged. Applicable plats will be recorded prior to FSP approval. 3. Please remove the E&SC and SWM-related sheets from the site plan. They're to be submitted & reviewed separately with the VSMP application (Sheets C3.0-C3.3, C6.0). Comment acknowledged. The ESC and SWM related sheets will be removed from the site plan and included in the VSMP submission. 4. Show public drainage easement over storm str/pipes 115 to 101. Drainage easements have been included. 5. Show public drainage easement over storm str/pipes I I I to 106 (pipes appear to carry stormwater from off -site that pass through the site). Drainage easements have been provided as requested. 6. Ensure SWM pipe meet easement width requirement shown on page 15, ACDSM. SWM easements have been revised accordingly to meet the easement width requirements. For the DI- Is, provide half -clogged design following VDOT drainage manual, chpt. 9. DI-I's have been updated to design at half clogged. Albemarle County Information Services (E91 1) — Brian Becker: I. No objection. Albemarle County Building Inspections — Betty Slough Add the following notes to the general notes page: . Retaining walls greater than 3 feet in height requires a separate building permit. Walls exceeding 4 feet in height require a stamped engineered design also. Walls require inspections as outlined in the USBC. Acknowledged. Stamped wall plans will be provided to the County for review and approval prior to installation. 2. Accessible parking spaces, access isles, and accessible route shall be installed in accordance with ICC ANSI AI 17.1-09 and the 2015 Virginia Construction Code. Noted 3. All water lines, sewer lines, and fire lines from the main to the structure located on private property MUST have a visual inspection performed by the building department. Comment noted. There are no proposed fire lines on this project 4. All roof drains shall discharge in a manner not to cause a public nuisance and not over sidewalks. Noted. All roof drainage is picked up in underground roof drains and tie to adjacent inlet structures. 8" roof drain pipes that tie to adjacent inlets have been added to the plan. S. Depending on the occupant load and egress travel paths, the pea gravel sidewalk on the south side may not meet egress travel requirements. The path has been revised to concrete. Albemarle County Dept of Fire Rescue — Shawn Maddox: I. No objection. Albemarle County Service Authority — Richard Nelson: I. No objection. Virginia Department of Health: 1. TBD — Pending: Comments will be forwarded upon receipt. No comments have been received upon time of resubmittal. Virginia Dept of Transportation — Adam Moore: 1. Requested Changes; see comment letter attached. Responses to letter provided separately. Albemarle County Planning Services ARB — Khris Taggard: 1. Requested changes; See ARB-2020-104 Action Letter. Responses to letter provided separately. We have included PDF copies of the plans and calculations for your review. If you have any questions or comments, please feel free to give me a call at 434.295.5624 or email clint.shifflett(CDtimmons.com . Sincerely, Clint Shifflett, PE