HomeMy WebLinkAboutSDP202100010 Review Comments Initial Site Plan 2021-03-25 (4)of At Christopher Perez
County of Albemarle Senior Planner
cpererg
Community Development De Department 434-296-5832 ext. 3443
�1@GI131Q'
Memorandum
To: Rob Cummings
Date: March 25, 2021
Subject: SDP202100010 Old Trail Block 32, Lots 34-40 Pocket Park - Initial Site Plan
The County of Albemarle Planning Division will recommend approval of the plan referenced above once the following
comments have been satisfactorily addressed (The following comments are those that have been identified at this time.
Additional comments or conditions may be added or eliminated based on further review.):
1. [35.11 Fees. The public notification fee of $435 was not paid prior to the SRC meeting. Please pay the fee prior to any further
review/action of the plan.
2. [32.5.2(a), ZMA2015-1 COD] On the final site plan provide a chart tracking how many units are already approved in Block
32. The maximum dwelling unit count for this block is 417 units. This will determine if the additional units are permitted.
3. [ZMA2015-1_COD] Garage and Driveway Construction Detail. The setbacks are incorrectly depicted for these lots. The
lots shall front on the pocket park, as they are amenity -oriented lots, and the private street shall be the rear of the lots.
Revise the site plan to depict the correct setbacks and relocate the proposed buildings to meet the front setback.
4. [ZMA2015-1_COD] Garage and Driveway Construction Detail. Each lot shall have a minimum of two (2) off street
parking spaces. Asphalt parking pads will be built with a minimum depth of 18 feet from the rear property lines adjacent to
the private road. Asphalt parking pads will be built with a minimum width of 18 feet to accommodate the required two
spaces. Also, there shall be a 3-foot minimum building separation from the parking pad to the building. Revise the final
site plan to address these requirements.
5. [ZMA2015-1_COD] Garage and Driveway Construction Detail. On the final site plan provide the grade of each driveway.
Driveway grades must be 8% or flatter.
6. [32.5.1(c), 4.12.16(b)] Design of Spaces. All parking spaces shall be designed so that no part of any vehicle will extend
over any lot line, right-of-way line, sidewalk, walkway, and driveway or aisle space. Revise the plan to omit the one (1)
foot driveway easements across the property lines, as this is not permitted. The width of the lots and the driveways shall be
revised to accommodate the required parking. Each parking space shall be a minimum of 9-foot-wide x 18-foot-long. Each
lot shall have a minimum of two (2) off street parking spaces.
7. [32.5.1(c), 32.5.2(b), 4.12, 4.12.8(a), 4.12.91 Alternatives available to provide minimum number ofparking spaces. The
three (3) required guest parking spaces are not provided. Per conversations with the applicant they are utilizing on -street
parking to meet the minimum number of required parking spaces. The required two (2) parking spaces per lot cannot be
located on the street but the guest parking spaces can. The approved road plan (SUB2018-164) already accounts for 88 on -
street parking spaces before the addition of these 3 new lots/units. Ensure additional parking spaces are available on this
road to meet the minimum required guest parking space requirement for these additional units.
On the cover sheet provide a note to this effect. Also, on the final site plan depict, label, and dimension the on -street
parking spaces and label they are for guests. Prior to final site plan approval these spaces shall be reviewed and approved
by Planning, Engineering, VDOT, and Fire Rescue. These spaces were not depicted nor labeled on the initial site plan, thus
these agencies have not reviewed nor considered the appropriateness or viability of these spaces on this road.
8. [32.5.2(b), 4.121 On the cover sheet revise the parking notes #17 and #18 to specifically relate to these 10 proposed units.
If you would like to keep the parking data you have provided for the entire development that is permitted, however, it
should be clearly noted and blocked off that these notes and the data in them are for the overall development. New parking
notes shall be provided specifically related to these 10 proposed units.
9. [32.5.2(b), 4.121 On the final site plan provide a revised parking schedule of parking required and the amount provided
specific to these 10 units.
10. [ZMA2015-1_Proffer #2, SUB2019-1371 Affordable Housing Units. The 7 original lots (Lots 34-40) in this section are
designated on the final subdivision plat as required affordable housing units. On the final site plan label 7 of these units
affordable housing units. Also, provide a note on the cover sheet that labels which of the 7 lots are affordable housing
units.
11. [ZMA2015-1 - COD] Provide a note on the cover sheet that state the minimum lot size shall be 1,000 SF for SFA units.
12. IZMA2015-11 Clarify the types of housing units proposed for the lots, as there are different requirements for different types
of units. I believe the proposed units are attached single-family (townhouse) units. On the cover sheet of the final site plan
provide a note to this effect.
13. [32.5.2(n)] Label and dimension all improvements depicted on the final site plan to include, driveways, the townhomes, all
sidewalks, and all other improvements.
14. [32.5.1(c), 32.5.2(a)] On the final site plan dimension the property boundaries and the new lot lines.
15. [32.5.1(c)] On the final site plan dimension the proposed structures and driveways.
16. [32.5.2(a)] On the final site plan provide the names of the owners, zoning district, tax map and parcel numbers and present
uses of abutting parcels.
17. [32.5.2(e)] Landscape Features. On the final site plan provide the existing landscape features as described in section
32.7.9.4(c).
18. [Comment] Remove the phase lines from Bicknell Street.
19. [32.5.2(n)] On the final site plan label all the proposed paving material types for all sidewalks, parking areas, and driveways.
20. [32.5.2(u)(iii), ZMA2015-1_COD] On the final site plan provide building elevations for all new or modified structures.
21. [32.7.2.11 Vehicular Access to Site. Each entrance onto any public street shall be designed and constructed as required by the
standards of the Virginia Department of Transportation. VDOT approval of the entrance to the site shall be required prior to
final site plan approval.
22. [32.8.21 A WPO plan shall be approved prior to final site plan approval.
23. [32.6] The final site plan shall meeting all the requirements of section 32.6 of Chapter 18 of the Code.
24. [Comment] The final site plan shall not be approved until all SRC reviewers have approved the plan. Their comments
attached.
25. [SUB2018-164] The approved road plan contains required street tree landscaping in the pocket park. To determine if there
is a conflict\ with the extended water line and the planting, the final site plan shall depict this planting (see below). It
appears it will cause a conflict and the tree shall be relocated out of the waterline easement. On the final site plan relocate
the single tree.
O i�4
P0C[6E'T` PARK. '.r
<< AA -AR
26. [Comment] Contrary to our previous discussions there is not an approved initial site plan nor an approved final site plan
for this specific section of townhomes. Rather there is an approved final subdivision plat (SU132019-137) and an approved
road plan (SUB2018-164).
27. [SRC Public Comment] Staff has received and forwarded to the applicant the adjacent neighbors' concerns about the
required parking for these units. Additionally, these residents are opposed to the additional units being added to this area.
SRC REVIEWERS
Engineering — Emily Cox
Comments attached
VDOT — Adam Moore
Comments attached
Fire and Rescue — Howard Lagomarsino
Comments attached
ACSA —Richard Nelson
Comments attached
RWSA — Dyon Vega
Comments attached
E911— Elise Kiewra
Comments attached
Building Official —Belly Slough
Comments attached
Please contact Christopher Perez in the Planning Division by using coerez e albemarle. org or 434-296-5832 ext. 3443 for further
information.
� AI
�h
�IRGRTF
County of Albemarle
Department of Community Development
Memorandum
To: Christopher Perez
From: Emily Cox
Date 19 March 2021
Subject: OLD TRAIL BLOCK 32, LOTS 34 - 40, POCKET PARK "A" AND 'B"
Initial Site Plan (SDP202 1000 10)
The initial site plan for OLD TRAIL BLOCK 32, LOTS 34 - 40, POCKET PARK "A" AND "B" has
been reviewed by Engineering. The following comments will need to be addressed before approval:
1. WPO201800077 must be amended to show this new proposed layout.
2. Plan must be signed, sealed and dated by professional registered in Virginia.
3. Please provide a detail for the proposed sidewalk.
4. Please provide a detail for the driveway curb entrances.
5. Provide the date of the topographic survey.
6. Show proposed topography, including first floor elevations and slopes of driveways.
7. Is the proposed sidewalk in an easement? Who will maintain this sidewalk?
8. Please show where roof drains will be directed.
Stephen C. Brich, P.E.
Commissioner
(Z)
COMMONWEALTH of VIRGINIA
DEPARTMENT OF TRANSPORTATION
1401 East Broad Street
Richmond, Virginia 23219
February 18, 2021
Christopher Perez
County of Albemarle
Department of Community Development
401 McIntire Road
Charlottesville, VA 22902
(804) 786-2701
Fax: (804) 786,2940
Re: SDP-2021-00010 - Old trail Block 32, Lots 34-40 and Pocket Park A - ISP
Dear Mr. Perez:
The Department of Transportation, Charlottesville Residency Transportation and Land Use
Section, has reviewed the above referenced Old trail Block 32, Lots 34-40 and Pocket Park A -
ISP, as submitted by Kirk Hughes & Assoc., dated January 05, 2021 and find it to be generally
acceptable.
A VDOT Land Use Permit will be required prior to any work within the right of way. The
owner/developer must contact the Charlottesville Residency land Use Section at (434) 422-9399
for information pertaining to this process.
If you have further questions please contact Max Greene at (434) 422-9894.
Sincerely,
Adam J. Moore, P.E.
Area Land Use Engineer
Charlottesville Residency
VirginiaDOT.org
WE KEEP VIRGINIA MOVING
Review Comments for SDP202100010 Initial Site Plan
Project Name OLD TRAIL BLOCK 32. LOTS 34 - 40, POCKET PARK "A" AND "B" - INITIAL - DIGITAL
Date Completed: Monday, March 15, 2021 Department/DivisionlAgency: Review Status:
Reviewer: Howard Lagomarsino
Fire Rescue Requested Changes
1) Please provide and indicate on plans the ISO needed fire flow for the structures and the ACSA available fire flow test
a) Available fire flow needs to meet or exceed the ISO required fire flow
2) Threads on (dire hydrants and fire department connections must be C & O, please indicate this on plans
3) Page 1 of plans, under ACSA water and sewer general notes - talks of a fire sprinkler system:
a) Provide location(s) of Fire Department Connection
b) Provide fire hydrant within 100 ft of fire department connection
4) Provide hydrants as mandated by the required fire flow (ex. fire flow required less than 1750 gpm, then average spacing is
500 feet and spaced so that the maximum distance from any point on the road frontage is no more than 250 feet - as the
required fire flow increases, the spacing decreases in distance)
5) The minimum acceptable turning radius is 25 feet, please indicate turning radius on plans
6) Each building requires a fire service access road that provides access to each building so that from the fire apparatus on the
road provides access to all sides of the ground level within 150 feet of the apparatus, which these plans appear to do. This
appartus access road must provide a minimum, unobstructed travel way of 26 feet due to building height over 30 ft. The road
width measurement is either face of curb to face of curb or edge of pavement to edge of pavement with the minimum and no
parking space can encroach on the travelway (example. - with no parking on the street, the road width must be 26 feet. If you
add parking on the street, the road width increases by the width of the nparking spaces).
7) Fire apparatus access road surface must be able to support the weight of 80,000 lb fire appartus in all weather
8) No overhead obstructions below the height of 13 ft 6 inches on fire apparatus access roads
Page: 1 County of Albemarle Printed On: 03/25/2021
Christopher Perez
From: Richard Nelson <rnelson@serviceauthority.org>
Sent: Thursday, March 18, 2021 2:57 PM
To: Christopher Perez
Subject: RE: Transmittal of SDP202100010 Old Trail Block 32, Lots 34-40 and Pocket Park A
Initial Site Plan
CAUTION: This message originated outside the County of Albemarle email system. DO NOT CLICK on links or open
attachments unless you are sure the content is safe.
Chris,
I recommend SDP202100010 Old Trail Block 32, Lots 34-40 and Pocket Park A - Initial Site Plan For approval with the
following conditions:
An update RWSA sewer capacity agreement will be required to account for the additional lots.
ACSA will need to approve the proposed service connections.
Thanks,
Richard Nelson
Civil Engineer
Albemarle County Service Authority
168 Spotnap Road
Charlottesville, Virginia 22911
(434) 977-4511
From: Christopher Perez <cperez@albemarle.org>
Sent: Tuesday, February 9, 2021 11:01 AM
To: Frank Pohl <fpohl@albemarle.org>; John Anderson <janderson2@albemarle.org>; Emily Cox
<ecox2@albemarle.org>; Matthew Wentland <mwentland@albemarle.org>; David James <djames2@albemarle.org>;
Adam Moore <Adam.Moore@vdot.virginia.gov>; Betty Slough <bslough@albemarle.org>; Loving
<brenda.loving@vdot.virginia.gov>; Elise Kiewra <ekiewra@albemarle.org>; Howard Lagomarsino
<hlagomarsino@albemarle.org>; Richard Nelson <rnelson@serviceauthority.org>
Subject: Transmittal of SDP202100010 Old Trail Block 32, Lots 34-40 and Pocket Park A - Initial Site Plan
All,
Transmittal of SDP202100010 Old Trail Block 32, Lots 34-40 and Pocket Park A - Initial Site Plan
The applicant submitted the above referenced plan digitally for review. Here is a LINK to the plan. Additionally, I have
attached the PDF of the plan incase you have trouble accessing the link. I'll send a Bluebeam invite shortly. This is a SRC
item, below is a short brief about the project.
Review comments are due by March 15, 2021.
PROJECT: SDP202100010 Old Trail Block 32, Lots 34-40 and Pocket Park A - Initial Site Plan
MAGISTERIAL DISTRICT: White Hall
TAX MAP/PARCEL: 055EO-01-32-03400, 055EO-01-32-03500, 055EO-01-32-03600, 055EO-01-32-03700, 055EO-01-
32-03800,055EO-01-32-03900,055EO-01-32-04000,and 055EO-01-32-OOOBO.
LOCATION: Vacant lots fronting Bicknell Street and Bishopgate lane.
PROPOSAL: Request for initial site plan approval for 10 single-family attached units. Three new lots proposed to be
added to the existing 7 lots, for a total of 10 lots.
ZONING: Neighborhood Model District (NMD) - residential (3-34 units/acre) mixed with commercial, service, and
industrial uses. In accordance with ZMA201500001 Old Trail Village.
ENTRANCE CORRIDOR: No
PROFFERS: Yes
COMPREHENSIVE PLAN: Block 32 is designated as Neighborhood Density Residential (3-6 units/acre) supporting uses
such as religious institutions, schools and other small scale non-residential uses within the Crozet Master Plan.
Christopher Perez
Senior Planner
Albemarle County
coerezAalbemarle.ora
office 434.296.5832 x 3443
401 McIntire Road, Charlottesville, VA 22902
7
Christopher Perez
From:
Dyon Vega <dvega@rivanna.org>
Sent:
Thursday, February 18, 2021 2:22 PM
To:
Christopher Perez
Cc:
vfort@rivanna.org; Richard Nelson
Subject:
Old Trail Block 32
CAUTION: This message originated outside the County of Albemarle email system. DO NOT CLICK on links or open
attachments unless you are sure the content is safe.
Chris,
RWSA has reviewed the site plan amendment for Old Trail Block 32 dated O1/05/21 and has the following comments.
General comment:
1. RWSA will require an updated flow acceptance when a project has a change in scope, time frame, or connection
point. Please send an updated flow acceptance.
Thanks,
Dyon Vega
Civil Engineer
RIVANNA
WATER 3 SEWERAUTHORITY
Rivanna Water & Sewer Authority
(434) 977-2970, Ext. 170
695 Moores Creek Lane
Charlottesville, VA 22902
www.nvanna.ora
Review Comments for SDP2O21OOO1O Initial Site Plan
Project Name I OLD TRAIL BLOCK 32. LOTS 34 - 40, POCKET PARK "A" AND "B" - INITIAL - DIGRAL
Date Completed: Thursday, February 11, 2021 DepartmenUDivisionlAgency: Review Status:
Reviewer: Elise Kiewra � CDD E911 No Objection
Page: 10 County of Albemarle Printed On: rOV2512021
Review Comments for SDP202100010 Initial Site Plan
Project Name: OLD TRAIL BLOCK 32, LOTS 34 - 40, POCKET PARK "A" AND "B" - INITIAL - DIGRAL
Date Completed: I Thursday, March 04, 2021 DepartmentlDivision/Agency: Review Status:
Reviewer: Betty Slough CDD Inspections . Requested Changes
Add the following note to the general notes page:
ALL water lines, sewer lines, and fire lines from the main to the structure located on private property MUST have a visual
inspection performed by the building department.
Add the following note to the general notes page:
Where the flood level rims of plumbing fixtures are below the elevation of the manhole cover of the next upstream manhole in the
public sewer, the fixtures shall be protected by a backwater valve installed in the building drain, branch of the building drain or
horizontal branch serving such fixtures. Plumbing fixtures having flood level rims above the elevation of the manhole cover of the
next upstream manhole in the public sewer shall not discharge through a backwater valve.
Add the following to the general notes page:
All roof drains shall discharge in a manner not to cause a public nuisance and not over sidewalks.
Page: 0 County of Albemarle Printed On: 031512021
Blue bdge Hearn District
VIRGINIA DEPARTMENT OF HEALTH
�01
L5�1 9
Christopher Perez, Senior Planner
Albemarle County Community Development
401 McIntire Road
Charlottesville, VA 22902
RE: Old Trail Village, Blk 32, Ph 2
Lots 34-40 and Pocket Park A
Initial Site Plan Review
SDP202100010
Mr. Perez:
Cho.wlr*sow/AweKr,ode
HeoNh DeparlmeM
1138 Rose HII Drive
Chorlottesvile. VA 22903
dike 434-972-6200 1 iex 434-972-4310
February 17, 2021
As requested, I've reviewed the Initial Site Plan, dated January 5, 2021 for the proposed
development, referenced above. Since all proposed construction will be connected to
ACSA water and sewer systems, I have no concerns and recommend approval.
If there are any questions or concerns, please give me a call, 434-972-4306.
Sincerely,
Alan Mazurowski
Environmental Health Supervisor
Blue Ridge Health District
alan.mazurowskikvdh.vir ig nia_gov