HomeMy WebLinkAboutSDP202000018 Correspondence 2021-03-24 (3)SHIMP ENGINEERING, P.C.
Design Focused Engineering
March 24, 2021
Richard Nelson
Albemarle County Service Authority
168 Spotnap Road
Charlottesville, VA 22911
RE: Response Letter #4 for SDP-2020-00018 (Brady Bushey Ford — Major Amendment)
Dear Richard,
Thank you for your review of the major site plan amendment for Brady Bushey Ford. This letter contains
responses to County comments dated March 23, 2021.Our responses are as follows:
1. Submit 3 hard copies and water/sewer data sheets for review and approval.
RESPONSE: 3 hard copies will be submitted to ACSA.
' Please clarify what fixtures are serving what building.
Audi/Porsche
Service
Building
VW
Mazda
Total
Lavatory
5
3
2
3
13
Urinal
0
2
0
0
2
Toilet
5
5
2
3
15
Fixture Value 60psi)
# of
Fixtures
Fixture Value
Lavatory
1.5
13
19.5
Urinal (Pedestal
Flush
35
2
70
Toilet (Flush
Valve
35
15
525
Site Total
614.5
Audi/Porsche/Service Buildin
Fixture Value 60psi)
# of Fixtures
Fixture Value
Lavatory
1.5
8
12
Urinal Pedestal Flush
35
2
70
Toilet Flush Valve
35
10
350
Audi/Porsche/Service Building Total
432
Volkswagen
Fixture Value 60psi)
# of Fixtures
Fixture Value
Lavatory
1.5
2
3
Urinal Pedestal Flush
35
0
0
Toilet Flush Valve
35
2
70
Volkswagen Total
73
912 E. High St. Charlottesville, VA 22902 1434.227.5140 1 shimp-engineering.com
Mazda Building
Fixture Value 60psi)
# of Fixtures
Fixture Value
Lavatory
1.5
3
4.5
Urinal Pedestal Flush
35
0
0
Toilet Flush Valve
35
3
105
Audi/Porsche/Service Building Total
109.5
3. Sheet C5: Adjust water main alignment as shown on PDF.
RESPONSE: Comment received. The water main alignment has been adjusted to be pulled away
from the parking spaces.
4. Call out WA tee and have a 6" reducer afterwards.
RESPONSE: Comment received. Please see the updated utility plan.
5. Shift proposed FHA 2' away from edge of pavement.
RESPONSE: Comment received. Please see the updated utility plan.
6. Labeling is congested behind Building B.
RESPONSE: Thank you for bringing this to our attention. The notes have been adjusted for better
legibility.
7. Move FHA closer to the end of island.
RESPONSE: Comment received. Please see the updated utility plan.
8. Sheet C6: One of the proposed trees in a parking island is within the proposed easement. This
may be corrected once the alignment is shifted.
RESPONSE: Comment received. Please see the adjusted water main and ACSA easement and the
revised landscape plan.
9. I will discuss the proposed trees within the ACSA easement along 250 with Pete and Jeremy.
RESPONSE: Thank you, we have received ACSA's approval separately and have provided this
documentation to ARB.
If you have any questions or concerns about these revisions, please feel free to contact me at
keane@shimp-en ing eering com or by phone at 434-227-5140.
Regards,
Keane Rucker
Shimp Engineering, P.C.