DRAWING INDEX
Sheet
1
Site Plan
2
General Notes/ Design Parameters
3-4
Details
5
Wall A - Sta. 0 to 5ta. 62
6
Wall B - Sta. 0 to Sta. 46.5
7
Wall C - 5to. 0 to Sta. 63
8
Wall D - Sta. 0 to Sta. 130.5
9 - 10
Wall E - Sta. 0 to 5ta. 168
N
42" Tall Safety Handrail or Fence
w/ Sleeve -It SDI Fence -Post Anchoring System
Cap Unit
E Secure to Top Um\
w/ Concrete Adhesive
Anchor Diamond Pro Units
Drainage Aggregate
Min 12" Thick
VDOT No. 57 Stone
x-E
----------------
'a
—„mow
^_ �,
Non -Woven Filter Fabric
Mirofi 140N or Equivalent
Geogrid Reinforcement (Typical)
Refer to Wnll Profile for Geogrid Type,
Geogrid Length (GL) and Location
41*
rl
— —
— — — —24" Vertical Spacing (TYp.)
Retained Soil
Reinforced Fill
�� _4" Dia. Drain Pipe Granular or Low Plasticity Soil
"_ !i Compacted Bockf ill See Drain Detail) ) Compact To Min 95% Standard
i' E Stone Leveling Pad GL Proctor Density
VDOT No. 21A Stone
i See Wall Prof ile
6" Minx 24' Wide .
, 0 RUITYPICAL RETAINING WALL CROSS SECTION
E TANG F
ELEX
TO RE.A,N
(Not to Scale)
F.T RUMMNG .EA'
xG YRNOE
LR "PGq°k EN.>5
TO RE --IN
O Al
NEW AULN qq� BuiLOiNC
A S B kI ' !{F NFW PgyStx! �'
RE p)o° s Es 9umN4
14 g5°
Scale: 1" = 100 FT
SITE PLAN 0 50 100
Anchor Diamond Pro Segmental Retaining Walls
Flow Automotive - 1300 Richmond Road
Albemarle County, Virginia
Site Plan Adapted From the Grading & Utilities Plan, Sheet No. C5 of 15
Dated February 21, 2020 (Rev. 8 - 3/8/21), Prepared By Shimp Engineering, P.C.
Site Plan For Illustrative Purpose.
Approx. Scale: 1" = 100 FT
Weephole w/Wall Drain Pro
Daylight Pipe
Through Wall
40' OC Spacing (Typ.)
g f 12-1/2" i
-----------------
0 0 1Iy2"
I
_ Rear Lip
18 1" Setback
8_1 '" >i
Straight
Split Face
I I
I I
I �
I I pri
I 1
I I
I �
� I
ANCHOR DIAMOND PRO UNIT
(Not to Scale)
Flow Automotive - 1300 Richr
Circeo
Geotechnical
5956 Buekland Mill Road
Roanoke, Virginia 24019
7AICHAf R. CIRCEO �'
3 Engineering, P.C.
ft. 021245 ��
Phone: (540) 366-2379
Scale:
1"=100 FT
Project No.
I RW-2530
fSS
Date:
02/07/21
ONAt LNG
1
Revision:
1 03/11/21
1 Sheet
I 1 of 10
NOTES:
1.0 STRIP VEGETATIVE AND ORGANIC SOIL FROM THE WALL
AND GEOGRID ALIGNMENT.
2.0 BENCH CUT ALL EXCAVATED SLOPES.
3.0 DO NOT EXCAVATE BEYOND EXCAVATION LINES SHOWN
ON PLAN UNLESS DIRECTED BY THE GEOTECHNICAL
ENGINEER TO REMOVE UNSUITABLE SOIL.
4.0 CONTRACTOR SHALL ENSURE TEMPORARY EXCAVATIONS ARE STABLE
AND PROVIDE EXCAVATION SUPPORT IF NEEDED.
5.0 GEOTECHNICAL ENGINEER SHALL VERIFY FOUNDATION
SOILS AS BEING COMPETENT PER THE DESIGN PARAMETERS.
6.0 LEVELING PAD SHALL CONSIST OF COMPACTED SAND, GRAVEL,
OR COMBINATION AND SHALL BE A MINIMUM 6-INCH THICK
LAYER WITH A MINIMUM WIDTH OF 24 INCHES.
AS AN ALTERNATIVE, A MINIMUM 3-INCH THICK LAYER OF
LEAN CONCRETE (FLOWABLE FILL) WITH A 28-DAY COMPRESSIVE
STRENGTH OF 200-300 P5I MAY BE USED AS A LEVELING PAD.
7.0 A 4-INCH-DIAMETER SLOTTED DRAINAGE PIPE SHALL BE INSTALLED
BEHIND THE WALL AND CONNECT TO WEEPHOLES INSTALLED AT
THE BASE OF THE WALL (40 FEET ON CENTER) AND EXTEND BEYOND
THE FINAL GRADE TO DAYLIGHT (SEE DRAIN DETAIL).
8.0 DRAINAGE AGGREGATE AND UNIT (CORE) FILL SHALL CONSIST OF
CLEAN ANGULAR &RAVEL (VDOT NO.57 STONE), MEETING THE FOLLOWING
GRADATION AS DETERMINED IN ACCORDANCE WITH ASTM D-422.
SIEVE SIZE PERCENTAGEPA55ING
1-112 INCH 100
1 INCH 95-100
1/2 INCH 25 - 60
NO.4 0-10
NO. 8 0-5
9.0 GEOGRIDS SHALL BE LAID HORIZONTALLY ON COMPACTED
BACKFILL FOR THE REQUIRED GE06RID LENGTH (GL) IN THE
TENSILE STRENGTH DIRECTION (PERPENDICULAR TO WALL FACE)
NOTED ON THE WALL PROFILE. THE GEOGRID SHALL BE
PLACED WITHIN ONE INCH OF THE FRONT FACE OF
THE UNIT BELOW AND EXTEND HORIZONTALLY
OVER COMPACTED FILL.
10.0 ANCHOR DIAMOND PRO UNITS MOLDED DIMENSIONS
SHALL BE 8 INCHES HIGH BY 18 INCHES LONG BY
12 INCHES DEEP AND SHALL NOT DIFFER MORE THAN
+ 1/8 INCH IN ANY DIMENSION.
11.0 A 1-INCH SETBACK PER UNIT (REAR LIP) SHALL BE MAINTAINED FOR
PROPER BATTER (I.E. 7 DEGREE CANT FROM VERTICAL).
12.0 GEOGRIDS SHALL BE PLACED WITHIN 1 INCH OF THE FRONT FACE
OF THE UNITS AND GEOGRID5 PULLED TIGHT (AFTER PLACEMENT
OF THE NEXT COURSE OF BLOCK UNITS) TO REMOVE SLACK
AND TO INTEGRATE GEOGRIDS AND UNITS.
13.0 FIELD ADJUSTMENTS OF BLOCK ALIGNMENT MAY BE MADE
ON NON -REINFORCEMENT LAYERS WITH THE USE OF SHIMS
OR ASPHALT SHINGLES TO RAISE ONE COURSE OF BLOCK BY
A MAXIMUM OF 1/4 INCH VERTICAL HEIGHT.
DESIGN PARAMETERS:
1 BUILDING CODES: 2015 VIRGINIA UNIFORM STATEWIDE BUILDING LODE (USBC)
14.0 REINFORCED FILL SHALL CONSIST OF GRANULAR SOIL FILL
AND 2015 INTERNATIONAL BUILDING CODE (IBC).
WITH U5C5 SOIL TYPES GP, GW, GM, &C, 5W, SP, SM OR 5C
2 THE WALL PROFILES ARE BASED ON THE GRADING & UTILITIES PLAN,
WITH A MINIMUM ANGLE OF INTERNAL FRICTION, OF 28 DEGREES
SHEET NO. C5 Of 15, DATED FEBRUARY 21, 2020 (REV. 8 - 3/8/21).
AS OUTLINED IN DESIGN PARAMETERS - NOTE 5.
PREPARED BY SHIMP ENGINEERING, P.L.
MAXIMUM PARTICLE SHALL BE LIMITED TO 4INCHES IN DIAMETER.
3 WALL DETAILS SHOWN ON THIS PLAN ARE FOR ANCHOR DIAMOND PRO
THE FINE FRACTION (MINUS NO. 40 SIEVE) SHALL HAVE A MAXIMUM
SEGMENTAL RETAINING WALL (SRW) UNITS MEETING THE NATIONAL
LIQUID LIMIT (LL) OF 40 AND A MAXIMUM PLASTICITY INDEX (PI)
CONCRETE MASONRY ASSOCIATION (NCMA) CRITERIA FOR SRW WALL SYSTEMS.
OF 20. THE BACKFILL SHALL BE FREE OF DEBRIS AND ORGANIC MATTER.
4 ENGINEERING ANALYSIS BASED ON USE OF STRATAGRID 56200 AND 56350
HIGHLY EXPANSIVE SOILS (MH-CH) SHALL NOT BE USED IN THE
GEOGRIDS. OTHER COMPATIBLE GEOGRIDS MAY BE SUBSTITUTED
REINFORCED FILL ZONE.
WITH THE APPROVAL OF THE WALL DESIGN ENGINEER.
5 THE DESIGN OF THE SEGMENTAL RETAINING WALL (SRW)
15.0 REINFORCED FILL SHALL BE PLACED IN 8-INCH LIFTS AND
A55UMES THE FOLLOWING PARAMETERS:
COMPACTED TO A MINIMUM OF 95% OF MAXIMUM STANDARD
Ym, Moist FRICTION
PROCTOR DENSITY (A5TM D-698) AND WITHIN + 3 PERCENTAGE
SOIL SOIL UNIT WEIGHT ANGLE COHESION
POINTS OF OPTIMUM MOISTURE CONTENT. COMPACTION TESTS SHALL
CONDITIONS Type (PCF) 0, (DEG) (PSF)
BE PERFORMED AS THE WALL IS INSTALLED. COMPACTION WITHIN
REINFORCED FILL Granular Soil 120 28 0
3 FEET OF THE WALL SHALL BE LIMITED TO HAND -OPERATED EQUIPMENT.
RETAINED SOIL On -Site Soil (MH) 120 26 0
FOUNDATION SOIL On -Site Soil (MH) 120 26 100
16.0 A VIBRATORY PLATE TAMPER SHALL BE USED TO DEN5IFY
NO.57 STONE. COMPACTION TESTS CAN BE WAIVED
WHERE NO.57 STONE IS USED AS REINFORCED FILL.
17.0 CONTRACTOR SHALL SLOPE SITE GRADES TO DIRECT SURFACE
RUNOFF AWAY FROM WALL AT END OF EACH DAY TO AVOID
WATER DAMAGING THE WALL WHILE UNDER CONSTRUCTION.
18.0 ANY SURFACE DRAINAGE FEATURES, FINISH GRADING, PAVEMENT,
OR TURF SHALL BE INSTALLED IMMEDIATELY AFTER THE WALL IS COMPLETED.
19.0 IF SITE AND SOIL CONDITIONS, WALL GEOMETRY, OR WALL
LOADING ARE DIFFERENT THAN THE DRAWINGS AND THE DESIGN
PARAMETERS, THE CONTRACTOR MUST CONTACT THE WALL DESIGN
ENGINEER PRIOR TO PROCEEDING WITH THE CONSTRUCTION OF THE WALL.
20.0 DETAIL FOR HANDRAIL OR FENCE POSTS AT THE TOP OF THE WALL
IS PROVIDED FOR PLACEMENT OF POSTS. FENCE P05T5 SHALL BE PLACED
DIRECTLY BEHIND THE WALL USING 5W SLEEVE -IT FENCE POST ANCHOR
SYSTEM.
1" Setback
)pen Cells
Filled With Stone)
1" Rear Lip
UNIT CONNECTION DETAIL
(Not to Scale)
6 SOIL STRENGTH PARAMETERS ARE BASED ON USE OF GRANULAR SOIL FILL
OR LOW PLASTICITY SOIL IN THE REINFORCED FILL ZONE.
ALL ENGINEERED FILL SHALL BE PLACED IN MAXIMUM 8-INCH LIFTS
AND EACH LIFT I5 COMPACTED TO A MINIMUM OF 95% OF
MAX. STANDARD PROCTOR DENSITY, AND WITHIN+ 3 PERCENTAGE POINTS
OF OPTIMUM MOISTURE CONTENT, USING PORTABLE COMPACTION EQUIPMENT.
DO NOT USE HIGH PLASTICITY CLAY (CH-MH), ROOTS OR TOPSOIL IN REINFORCE
ZONE. ANY SOFT, SATURATED SOIL ENCOUNTERED IN 5UBGRADE SHALL BE
UNDERCUT AND REPLACED WITH CRUSHED STONE TO STABILIZE THE
FOUNDATION 5UBGRADE OR AS DIRECTED BY THE GEOTECHNICAL ENGINEER.
WALL A - MAX. WALL HEIGHT = 7.33 FEET (INCLUDING EMBEDMENT)
WALL B - MAX. WALL HEIGHT = 6 FEET (INCLUDING EMBEDMENT)
WALL C - MAX. WALL HEIGHT = 8 FEET (INCLUDING EMBEDMENT)
WALL D - MAX. WALL HEIGHT = 6.67 FEET (INCLUDING EMBEDMENT)
WALL E - MAX. WALL HEIGHT = 12 FEET (INCLUDING EMBEDMENT)
FRONT SLOPE = LEVEL TO MAX. 2H:1V
BALKSLOPE BEHIND THE WALL = LEVEL TO MAX 2HAV
SURCHARGE AT TOP OF WALL = 100 P5F
MIN FACTOR OF SAFETY (SLIDING) = 1.5
MIN FACTOR OF SAFETY (OVERTURNING) = 2.0
MIN FACTOR OF SAFETY (BEARING CAPACITY) = 2.0
q = DESIGN SOIL BEARING PRESSURE = 1,000 P5F TO 2,000 PSF
(SEE NOTE ON WALL PROFILES)
MB. 021245
3ltt�Zi
Albemarle
Circe0
Geotechnical
Engineering, P.0
nia
5956 Buckland Mill Road
Roanoke, Virginia 24019
Phone:(540) 366-2379
Scale: 1 N/A I Project No. I RW-2530
Date: 02/07/21
I
Vehicle Guard Post (Standard VDOT GR2) @ 6'-3" O.C.
Use Utility Knife to Cut lop Geogrid Layer
Drive Post Through Geogrid Layers)
Offset Post Spacing To Avoid Conflict with Base of Sleeve -It 5D1
Cut Geogrid Around Sleeve
Use Utility Knife to Cut Geogrid
15.25"
Reinforced Fill
42" Tall Pedestrian Guard or Fence Post
30.6"
Min 12" Thick
VDOT No. 57 Stone
Sleeve -It SD1 Post Spacing (Verify) i L Start Geogrid Approx. 1"
From Front of Units
VDOT GR2 Post Spacing (Verify) Anchor Diamond Pro Unit
VEHICULAR GUARD POST THROUGH GEOGRID DETAIL
(Not to Scale)
Reinforced Fill
i6—
E= = Min 12" Thick
• -
\Ir1�\�Ir1r.
Imo���inie��n
==
arse
��
o Sleeve -It SDI
} d Fence -Post Anchor
S/Ys/Jt]e�m�
N i
L
I I
O I
O
ar
I I
I I
I I
I I
I I
I I
I I
I I
;
Start Geogrid Approx. 1'I
From Front of Units
SRW Unit
GEOGRID PLACEMENT DETAIL
(Not to Scale)
30.611
42" Tall Fence or Handrail Post
Sleeve -It 5 D1 Fence -Post
Anchor System - Top Dia. 7.4"
Grout Fill After Post Installation
Bottom Dia. 9.4"
FFilter Fabric - 4 FT Wide
Mirofi 140N or Equivalent
r Cantilever Base 30.6" L x 15.3"W
A'
Reinforced Fill
SLEEVE -IT FENCE POST DETAIL
Mo. 021245
3ltt�Zi
Standard GR-2 Guard Rail Post
Min 24" Clear Distance Behind Top of Wall,
Max. 6'-3" O.C. Post Spacing
Drive Post Through Geogrid Layer(s)
GUARDRAIL POST DETAIL
(Not to Scale)
Automotive -
Circeo 5956 Buckland Mill Road
GEng! nical Roanoke, Virginia 24019
_ Engineering, P.C. 9
Phone:(540) 366-2379
01 Project No. I RW-2530
WALL A
426
424
422
420
4}-
418
0
0
d 416
W
0
a
Q
O
3
a
Drain To Daylight
@ End of Wall
414
412
-00
408
Surcharqe = 100 psf
TOC = 418.33
TOW = 418.00
GL = 7.5 FT
6L=6FT I I� 6L=7.5 FT
TOC = 420.33 (HP)
TnW = 49n M
GL=7
GL = 7.5 FT
Lem
`BOW = 412.00 \
GL 7.5 FT I GL=9 FT
% BOW = 410.00 -6" Thick Stone
BOW = 408.67 (Low Point) I ICI 1I L Drain Pipe to Daylight - 40 FT O.C. (Typical) Levee l
406�r�
n I DO 18 37. 20 30 5 40
I
I j I Station (ft)
I I I I
LF GL = 6 FT —yam— GL = 7.5 FT — I GL = 9 FT GL = 7.5 FT
I I I
ENLARGED SITE PLAN VA \ CO ,� C' u
LEGEND
® Cap Unit (4" Height)
Anchor Diamond Pro Units (8" Height x 18" Width)
Leveling Pad (Min. 6" Thick Stone or Min. 3" Lean Concrete)
TOC Top of Cap Unit
TOW Top of Wall (Excluding Cap Unit)
BOW Bottom of Wall (Including Embedment)
200 ' StrotoGrid S6200
0 4" Drain Pipe to
/ LL. ,
/ 3 �Sta I
LLJ >,
o I \V
WALLA ---
w/ 42" Tall Pedestrian Guard
I \I
I
I
Begin Steps
I
QD
y
i
8l�
i
o
o >o
ta. 57 .LLJ CY
(/l LiJ
_ A
Sta. 62
Use Granular or Low Plasticity Soil
In Reinforced Fill Zone
RETAINING WALL A
Sta. 0 to Sta. 62
Viewed From Front Face of Wall
= Design Soil Bearing Pressure = 1,500
Abut Wall A To
Building Foundation
P. Wall
M d Transition To Sidewalk
" @ EL. 420.42
a
_ N
GL=6FT
� N
W
BOW = 418.67
— 1
BOW = 418.00
I I
L 6FT BOW = 416.00
= I
I I
—Concrete Steps
I
I I
1 I
I I
I I
Grade at Bottom of Wall
48 50 97 60 62
I I I
I I I
0 6eogrid �l
6L=66eogrid —I
FT
I �
Scale: 1" = 20 FT
0 10 20
rives rnulumunve - •avv rocnmunu muou
r�p.LTN 0—i Albemarle CountL Virginia
CIRCEO GEOTECH
Circeo 5956 Buckland Mill Road
i ,� — Geotechnical
Z � Engineering, P.C. Roanoke, Virginia 24019
HAE R. culnu Phone: (540) 366-2379
No. 021245
3!li/Z�
Scale: H: 1"= 5 ft.
S%ONAL Evk V: 1"= 5 ft. Project No. RW-2530
Date: 02/07/21
Surcharge = 100 psf
WALL B
TOC = 421.00
426 TOW = 420.67
Min 42" Toll Pedestrian Guard
TOC = 421.00
Abut Wall g
TOW = 420.67
To Building as
5
Foundation Wall
m
42
m
0 a
V) O 420
, GL=6FT GL=4.5 FT
=
F- GL=4.5 FT GL=6FT
W
eny
l!J 418
� 6L=6FT 6L=4.5 FT
_
3 6L = 6FT
416
GL=6FT
BOW = 418.00
} BOW = 418.00 GL=4.5 FT
of =
BOW 416.00
BOW = 416.00
ala _
BOW = 418.67 i i r i 61-=6 FT
..Thick Stone Proposed Grade at Bottom of Wall
_
Drain Pipe to Daylight
BOW = 414.67 (Low Point)
—Leveling Pad
alz
0 10.5
IB 30 31.5
40 46.5
I I
I � 6L = 4.5 FT ►I�
1
6L = 6 FT Station (ft) 6L = 4.5 FT �
I 1
1
I
�
Reinforced Fill
<<<
WALL B
/ � �
B U I L
w/ 42" Tall Pedestrian Guard f
E X. SALE'
<><><
Filter Fabric
SEGMENTAL E!._O',K
/1
/
ET.
�T�
WALL $MAX HEG i
VDOTN0.57Stone :ti'+'{'
/�
EEE
a<a<>< - --------
-----------
0 00 00 00
Sta 0
to.
BEE
'<
/Q 57
At Abutment, Alternate Full Unit
See Wall Abutment Detail, This Sheet
Ex. Structure
with Half Unit Every Other Course.
Do Not Attach to Structure.
II
Sta. 40
/
I I I i
' ;• �
rr-i
,•I ./1I;�,,ll\ I
\
Scale: 1" = 20 FT
WALL ABUTMENT DETAIL
<
v 3
�
(Not to Seale)
ENLARGED SITE PLAN
Sta.46.5
c��/,
o io zo
LEGEND
Flow Automotive
- 1300 Richmond Road
Use Granular or Low Plasticity Soil
In Reinforced Fill Zone
r`p�(,Tif O
J
' `'i
�'.
Albemarle
County, Virginia
® Cap Unit (a" Height)
0 Anchor Diamond Pro Units (8" Height x 18" Width)
Leveling Pad (Min. 6" Thick Stone or Min. 3" Leon Concrete)
Circeo
Geotechnical
1Engineering, P.C.
CIRCEO GEOTECH
5956 Buckland Mill Road
Roanoke, Virginia 24019
TOC Top of Cap Unit
RETAINING WALL B
Ov VICNA R. CIRCE y.
Phone: (540) 366-2379
TOW Top of Wall (Excluding Cap Unit)
Sta. 0 to Sta. 46.5
�• 021:2�
Scale:
H' 1"= 5 ft.
BOW Bottom of Wall (Including Embedment)
'j!/(�Z(
�^f
V: 1"= 5 ft.
200 — • Strota6rid SS200
Viewed From Front Face of Wall
S�ONAL
Project No. RW-2530
Date:
02/07/21
E�
GL Geogrid Length (ft) 0 4" Drain Pipe to Daylight
q = Design Soil Bearing Pressure = 1,500 psf
Revision:
1 03/11/21
Sheet 6 of 10
WALL C 41
TOC = 404.33
41
TOW = 404.00
\
o
1
}
o�
U
}
j 4(
d
3
W
t
L
4(
t
u)
4(
Drain To Daylight
@ End of Wall
1
Mom
-
MMMIMMMMIMM
■rw���r�■■��i
mim
M",
=r,■■nr,M■r
mmmmm■■■mm■�■s���.�.�
i
1�I�!Si1�■li•■•�■•�■•■■A���������i•�■�����■III���:���11��1
Immm'"W"
��l�Glli�����irir
r•rr•rr•rr•rr•r■rrrt
rrirrr��i�s�
Ii-1��VI-■��ni
wr��_�_�_■�
mdammm
■♦���I��■■I�Ir�r��M�r
rr�m____--_--
MI
im
1
I I I
GL=4.5FT I GL=6FT
I 1
Station (ft) I Proposed Grade at Bottom of Wall
I
GL=7.5FT GL=6FT
XV 1HO13H 'XVVTI vv^&-L- `-
13a '�NO� w�42"Tall Pedes
Bi` 0
ENLARGED SITE PLAN L x�`
1 I
I I
I
I� 6L = 4.5 FT �
Scale: 1" = 20 FT
0 10 20
LEGEND nvw nawnW11VW - 40WW n�cnmvna R„IAU
Use Granular or Low Plasticity Soil tPITN 0 Albemarle County, Virginia
® Cap Unit (4" Height) In Reinforced Fill Zone V1 1' CIRCEO GEOTECH
0 Anchor Diamond Pro Units (8" Height x 18" Width) a� I� Circeo 5956 Buekland Mill Road
0 Geoteneerinl
Leveling Pad (Min. 6" Thick x 24" Wide Stone) � � _3 Engineering, P.C. Roanoke, Virginia 24019
roc Top of Cap Unit RETAINING WALL C OV MICHA R. CI.` (< Phone: (540) 366-2379
TOW Top of Wall (Excluding Cap Unit) . NB. OQ21245 �•
BOW Bottom of Wall (Including Embedment) Sta. 0 to Sta. 63 '��� Scale: H' VI 5 ft.
— — 200 — ' StratoGrid 56200 Viewed From Front Face of Wall G� V: 1"= 5 ft. Project No. RW-2530
ONAL �� Date: 02/07/21
GL 6eogrid Length (ft) 0 4" brain Pipe to Daylight q = Design Soil Bearing Pressure = 1,500 psf Revision: 03/11/21 Sheet 7 of 10
mopnm Min Tall Pedestrian Guard!I.!!!!!!!!!!!!.I!!!MKIM r • 1 !.1
ME • !!!!.I!!!!!!I� !I.!!!!!!!!!!!!.I!!!-.
!!W • !!11!!!!.I!!!!!!I.!!!!!!!!!!!!.I!!!!!!I.!!!!!!!!!!!!.I!!!I- • . 1
!1!! !.•I
!!i! lI�I
!.I! lICI.!!!!!!!!!!!!.I!!!!lICI.!!!!!!!!—_— 11�\
.�,!I�!!!!.I!!!!!ll.���!!!!!l����•���---_— _.�1�!—!!!.IlI-!!!!It!!!!.1!!!!!-!.I!l111!!lI..1!!!!-!!!I\1.11..1
!r.l����.���--'—_— ���!!lI.II!!!ll1.I.!!!\•!!!!—!!!.IlI-!!!!■�!�!!.1!!!!!—!.I!!r'1!!lI..1!!!!—!!!\�-11..1 �
���1�•-I!!!!�•!I.!!■�!!!!�.!!lI.II!!!!l1.1.!!!\•!!!!—!!!.IlI-!!!!It!_.�Jl.1!!!!!—!.I!!rI!!lI..1!!!!—!!!\�1!"..1
■\!!_!_!_�1.I!!!!■•!I.!!I�!!!!\.!!lI.II!!!ll1.I.!!!\•!!!!—!!!.IlI-!!!!■�!lr��•��������1��5���_�_•��•�_�_�__________\_\\-_C_.-•
1 Ir�7��--���� I�------
_ _'ANlr��i1i�lliaifil.!!i!!!A!!!A! lAIS!!!!!!Al--•i llii
.r..l��lmmiim�.�iQii—.t..lAf•!!!A ..! I..Irirl..lrirl..lr
!!AI-!mmma•m lII..I .IlA!!lAIS!!!!!!A!!!A!. lAI.!!!!!!!!i� �lCr
ME
ME
ME
. � � rr�rrirlr�i, - .rr�irrrirr irrlrirlr�i�r -��rrirrlrir rrrr�rrz��r. �r1-!lrr�ir� � �; .
a
wosir� �.� �,�u�s ......ri.arr✓i�rri
a�
ll
: • ....
BOW= 398.00
Drain Pipe to Daylight - 40 FT O.C. (Typicall)
—Proposed Grade at Bottom of Wall
. r ,
t
'
v►I ..
Sta. 20
. t2o•. ' 0
• ..P,
?a. /
�0
:.
WALL b
i ' FT
I' �C
ENLARGED • 10 20
•• Richmond Road
Use Granular or Low Plasticity Soil Flow Automotive -
Cap Unit (4" Height) In Reinforced Fill Zone CIRCE0 GEOTECH
Albemarle County, Virginia
Anchor Diamond Pro Units (8" Height x 18" Width) 5956 Buckland Mill Road
=�-CGeeootechnical
Leveling Pad (Min. 6" Thick x 24" Wide Stone) Roanoke, Virginia 24019
TOC Top of Cap Unit RETAINING WALL 0
. '
• I i• BOW Bottom . 0
WALL E
FE
400
398
396
394
392
} 390
388
0 386
384
d 382
W
380
378
376
374
372
370
TOC = 382.33
TOW = 382.01
6L=6 FT
Min 42" Tall Pedestrian Guard
TOC = 389.00
TOW:388.67
GL=8 FT
GL = 10 FT
6L = 10 FT
GL =i 10 FT
= 10
Parking Lot/Vehicle Surcharge = 00 psf
w�l w
• M
������r■w� ■wwww■� �wwwwl �w��
• � i �■wwr�w■��wwwwl�wwww■
mow■ S�LS9i�� ■ww■ �w■� �wwwwl �wwww■
1� �r�i
� A9ii■w�ri
I.rrwli_i1osSS_�_!dw_
- irY.IrirlRlrirYiri✓•
wwwwwwwwww�■www
���wwwwwww�■www
- �ir•rY.�irY.�r.rrr�
�����
- _
•
_ _
_ _�
Y�mQ�■1
MAN_�__■____
•✓•IRIi�iJ�Y.ir•r�
�w�■wwww
r��n■n���
sir■rrir•
iw�■wwwwww■�wwwwwwwwwwww�■www
wwi■i✓•Y■w
- r•rwwrr✓•wwi✓•Y■wir•
wwwwwwwwww�■www
�w�■wwww
�w�■wwww
�Iri�✓•IRlri
�w�■wwww
wwwwwwwwww�
- r�iir�rirlRli.irl.r
wwwwwwwww�rn■www
■www
_ �t1�1�■w�wr
ww���l�IlA
rsilww
-
�
-'
ommmmma000wwwwwwww�i�w�����
6L=81ff /
I 6" Thick Stone I
= 380.67 I
Leveling Pad
Drain Pipe to Daylight - 40 FT O.C. (Typical) !
O I 12 38 30 40 50 ry 60 66 70
1 I I I I
I 6L = 6 FT I=g �� 6L = 10 FT I GL = 12 FT
�Im
Iq = 1,000 psf q = 1�,250 ppsf q = 1,500 psf q = 1,750 pst�1
\ N
06,
ta. 0 �6
- -- OK-- -Sta. 20 -._
- - - —-_-- Sta. 40
OS
ENLARGED SITE PLAN
LEGEND
®
Cap Unit (4" Height)
0
Anchor Diamond Pro Units (8" Height x 18" Width)
Leveling Pad (Min. 6" Thick Stone or Min. 3" Leon Concrete)
TOC
Top of Cap Unit
TOW
Top of Wall (Excluding Cap Unit)
BOW
Bottom of Wall (Including Embedment)
— — 200 • —
'Stratogrid 56200
350 — '
Stratogrid 56350
0 4" Drain Pipe to
'BOW = 380.00
Additional Weephole @ Low Point
Proposed Grade at Bottom of Wall
80
Station (ft)
-
90 100 ISO
GL=14FT
q = 2,000 ps
CQ-
0)
NI 7 to. 168
I� sSta L40 Xd 1St° �ti�
80 0 Jed H •85$CJZ
Use Granular or Low Plasticity Soil
In Reinforced Fill Zone
RETAINING WALL E
Sta. 0 to Stu. 120
Viewed From Front Face of Wall
q = Design Soil Bearing Pressure (p
- �- WALL E
w/ 42" Tall Pedestrian Guard
and Traffic Guard As Specified
Al
• W
w
• •�
EwwWA
�MMEM •
O
N
.r
t5
w
c
J
.c
u
0
= 378.67 (Low Point)
120
I
Scale: 1" = 20 FT
0 10 20
// Circeo 5956 Buekland Mill Road
= Geotechnical
3 Engineering, P.C. Roanoke, Virginia 24019
R R. 0 Phone: (540) 366-2379
No.021245 �,
3lll�Z�
Scald:
Project No-TRW2530
�OA+AL �� Date: 1 02/07/21
WALL E
w
c
0
t
i
d
w
G
400
398
396
394
392
390
388
386
384
382
380
378
376
374
372
370
Parking Lot
TOC = 384.33
TOC = 382.33
TOW = 382.00
Grade at Bottom of Wall
120 132 141 150 153 160 16
GL=14FT I 6L=12FT I�L=10FT GL=8FT I 51 &L=6FT I
spi
q = 2,000 psf I q = 1,750 psf I q = 1,500 psf q = 1,250 psf q = 1,000 psf I
LEGEND
® Cap Unit (4" Height)
Anchor Diamond Pro Units (8" Height x 18" Width)
Leveling Pad (Min. 6" Thick Stone or Min. 3" Lean Concrete)
TOC Top of Cap Unit
TOW Top of Wall (Excluding Cap Unit)
BOW Bottom of Wall (Including Embedment)
200 Stratagrid 56200
350 Stratagrid 56350
GL Geogrid Length (ft) 0 4" Drain Pipe to Daylight
Use Granular or Law Plasticity Soil
In Reinforced Fill Zone
RETAINING WALL E
Sta. 120 to Sta. 168
Viewed From Front Face of Wall
q = Design Soil Bearing Pressure (psf)
Flow Automotive - 1300 Richmond Road
Albemarle County. Virginia
irCGoceotechnical// c_Engineering, P.C.
4A No. 021245
Q 3
Scale: H: r"= 10 ft.
5956 Buckland Mill Road
Roanoke, Virginia 24019
Phone:(540) 366-2379
Fax: (540) 904-6200
Project No. I RW-2530