Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ARB202100027 Plan - Revision 2021-05-10
FINAL SITE DEVELOPMENT PLAN LEGEND EXISTING NEW DESCRIPTION BOUNDARIES BENCHMARK SITE PROPERTY LINE ADJACENT PROPERTY LINE BUILDING SETBACK PARKING SETBACK SITE TEXT 10 10 PARKING COUNT TOPOGRAPHY INDEX CONTOUR INTERVAL CONTOUR 311.5 x z b SPOT ELEVATION 311.5 TO x z TOP OF CURB ELEVATION 311.5 TW x z b� TOP OF WALL ELEVATION 311.5 B W x x BOTTOM OF WALL ELEVATION - ... - ... - STREAM STREAM BUFFER 100 YEAR FLOODPLAIN BUILDING BUILDING RETAINING WALL STAIRS EDGE OF PAVEMENT ROAD CENTERLINE FRONT OF CURB BACK OF CURB CG-12 TRUNCATED DOME SIDEWALK BIKE PARKING HANDICAP ACCESSIBLE AISLE HANDICAP PARKING MATERIAL CONCRETE RIPRAP --------------------------------------- ASPHALT EC-2 MATTING EC-3 MATTING 0 WETLAND TREELINE X X FENCE UTILITY UTILITY POLE GUY WIRE oHu GHU OVERHEAD UTILITY ucu UGU UNDERGROUND UTILITY STORM STORM MANHOLE q q DROP INLET STORM SEWER ROOF DRAIN OAKIITAmw SANITARY MANHOLE SANITARY SEWER MAIN S SANITARY SEWER LATERAL S WATER W WATER LINE W O O WATER METER 0 0 WATER METER VAULT FIRE HYDRANT A FIRE DEPARTMENT CONNECTION GAS GAS GAS LINE GAS EASEMENTS CONSTRUCTION GRADING ACCESS SIGHT DISTANCE UTILITY STORMWATER FACILITY MAINTENANCE STORMWATER ACCESS DRAINAGE SANITARY WATERLINE GASLINE NOTE: 1. THE SIZE OF THE SYMBOLS MAY VARY FROM WHAT IS SHOWN. OWNER Windmill Ventures LLC 535 Foxdale Lane Charlottesville, VA 22903 DEVELOPER 999 Rio Road Development, LLC 912 East High Street Charlottesville, VA 22902 (434)218-0513 PLAN PREPARATION Shimp Engineering, P.C. 912 East High Street Charlottesville, VA 22902 (434)227-5140 ZONING NMD - Neighborhood Model District ZMA201900001 approved on March 4, 2020 The Code of Development associated with ZMA20190001 (revised January 29, 2020) establishes design guidelines, specific regulations, and block characteristics for the development of this property Overlays: Entrance Corridor, Airport Impact Area Initial site plan SDP202000045 approved on 7/22/2020 MAGISTERIAL DISTRICT Rio SOURCE OF TITLE DB 4505 PG 218 SETBACKS Per approved ZMA201900001, setbacks are provided as follows Block 1 (Mixed Use) Block 2 (Residential) FRONT MINIMUM: 3' FRONT MINIMUM: 5' FRONT MAXIMUM: 50' FRONT MAXIMUM: 40' SIDE MINIMUM: None SIDE MINIMUM: 3' SIDE MAXIMUM: 10' SIDE MAXIMUM: 15' REAR MINIMUM: None REAR MINIMUM: 10' REAR MAXIMUM: None REAR MAXIMUM: None BUILDING HEIGHT Per approved ZMA201900001, maximum building height in Block 1 and 2 is 35'. All non-residential uses shall be limited to one (1) story, or twenty-five (25) feet. SOURCE OF BOUNDARY AND TOPOGRAPHY Boundary & topographic survey provided by: Meridian Planning Group, LLC, March 20, 2019. BENCHMARK Datum for topography is NAVD 88 Visually verified by Shimp Engineering Staff on 12/23/2020 FLOODZONE According to FEMA Flood Insurance Rate Map, effective date February 4, 2005 (Community Panel 51003CO279D), this property is not located within a Zone AE 100-year floodplain. RESERVOIR WATERSHED This site is within the Meadow Creek Watershed. This site is not within a watershed of a public water supply. WATER & SANITARY SERVICES Site is served by ACSA public water and sewer. GENERAL CONSTRUCTION NOTES 1. Prior to any construction within any existing right-of-way, including connection to any existing road, a permit shall be obtained from the Virginia Department of Transit (VDOT). This plan as drawn may not accurately reflect the requirements of the permit.Where any discrepancies occur the requirements of the permit shall govern. 2. All materials and construction methods shall conform to the current specifications and standards of VDOT unless otherwise noted. 3. Erosion and siltation control measures shall be provided in accordance with the approved erosion control plan and shall be installed prior to any clearing, grading or other construction. 4. All slopes and disturbed areas are to be fertilized, seeded and mulched. 5. The maximum allowable slope is 2:1 (horizontal:vertical). Where reasonably obtainable, lesser slopes of 3:1 or better are to be acheived. 6. Paved, rip -rap or stabilization mat lined ditch may be required when in the opinion of the County Engineer or designee it is deemed necessary in order to stabilize a drainage channel. 7. All traffic control signs shall conform with the Virginia Manual for Uniform Traffic Control Devices. 8. Unless otherwise noted all concrete pipe shall be reinforced concrete pipe - Class III. 9. All excavation for underground pipe installation must comply with OSHA Standards for the Construction Industry (29 CFR Part 1926). GENERAL WATER & SEWER NOTES 1. Work shall be subject to inspection by Albemarle County Service Authority inspectors. The Contractor will be responsible for notifying the proper service authority officials at the start of the work. 2. The location of existing utilities across the line of the proposed work are not necessarily shown on the plans and where shown, are only approximately correct. The contractors shall on his own initiative locate all underground lines and structures as necessary. 3. All materials and construction shall comply with the current edition of the general water and sewer construction specifications as adopted by the Albemarle County Service Authority. 4. Datum for all elevations shown in National Geodetic Survey. 5. The contractor shall be responsible for notifying "MISS UTILITY" (1-800-552-7001). 6. All water and sewer pipes shall have a minimum of 3.5 feet of cover measured from the top of pipe, over the centerline of pipe. This includes all fire hydrant lines, service laterals and water lines, etc. 7. All water and sewer appurtenances are to be located outside of roadside ditches. 8. Valves on deadend lines shall be rodded to provided adequate restraint for the valve during a future extension of the line. 9. Trees are not permitted in the ACSA easement. 10. The contractor shall be responsible to comply with the no -lead regulation regarding brass fittings effective January 4, 2014 (Senate Bill 3874 which amends the Safe Drinking Water Act). 11. All public water and sewer facilities shall be dedicated to the Albemarle County Service Authority. 12. Backflow prevention is required for all connections to the water main. ITE Trip Generation AM PM Daily Use Description ITE Oty In I Out I Total In Out Total Total Single Family Detached 210 1 5 2 6 8 4 2 6 66 AM PM Daily Use Description ITE OtY In I Out I Total In I Out Total Total Multifamily (Low -Rise) 220 1 20 2 8 10 9 5 14 110 EXISTING USE Vacant Land PROPOSED USE Residential, Gross residential density: 13 du/ac Lots 1-7: Multifamily, 2 units/building, 14 units total Lots 8-13: Attached single-family, 6 units total Lots 14-18: Single-family detached, 5 units total LAND USE SCHEDULE EXISTING Area % Building 3,939 SF 4.7% Pavement 2,348 SF 2.8% Sidewalk 0 SF 0% Open Space 77,261 SF 92.5% Total= 83,548 SF (1.918 ac.) PROPOSED Area % Building 14,128 SF 16.9% Pavement 23,902 SF 28.6% Sidewalk 9,784 SF 11.7% Open space 35,734 SF 42.8 % Total= 83,548 SF (1.918 ac.) PARKING SCHEDULE Block 1 (Mixed Use) Multifamily units: 1 bedroom, 1.5 spaces per unit, 14 units total = 21 spaces required = 21 spaces provided Block 2 (Residential) Multifamily units (Single -Family Attached): 2 or more bedrooms, 2 spaces per unit, 6 units total = 12 spaces required = 12 spaces provided Single family detached: 2 spaces per unit, 5 units total = 10 spaces required = 10 spaces provided Total of 43 spaces required, maximum of 20% provided, 52 spaces provided FIRE FLOW Total estimated flow is 3,526 gpm. Ten -pound drop for a Q20 could not be achieved at the time of hydrant flow test. ISO needed fire flow is 1,500 gpm. RECREATION Recreational area shall comply with conditions of approved ZMA20190001. Block 1 and 2 shall provide amenity area no less P Y PP P tY than 20% of the total block area. Section 4.16 of the Albemarle County Zoning Ordinance shall apply to all recreational facilities. Block 1: 8,364 SF required, 8,518 SF provided. Block 2: 8,276 SF required, 10,082 SF provided. SIGNS All signs and pavement shall conform with the latest edition of the MUTCD Guidelines. A sign permit must be issued in accordance with the Albemarle County Sign Regulations prior to placement of any signs on -site. Contractor shall provide handicap signs as shown on plan. GENERAL NOTES 1. The information and data shown or indicated with respect to the existing underground utilities at or contiguous to the site are based on information and data furnished to the owner and engineer by the owners of such underground facilities or others. The owner or engineer shall not be responsible for the accuracy or completeness of such information or data. The contractor shall have full responsibility for confirming the accuracy of the data, for locating all underground utilities, for coordination of the work with owners of such underground utilities during construction, for the safety and protection thereof and repairing any damage thereto resulting from the work. All of these conditions shall be met at no additional cost to the owner. The contractor shall contact "Miss Utilities" of Virginia at 1-800-552-7001 prior to the start of work. 2. When working adjacent to existing structures, poles, etc., the contractor shall use whatever methods that are necessary to protect structures from damage. Replacement of damaged structures shall be at the contractor's expense. 3. The contractor shall be responsible for protecting all existing site structures from damage and coordinating work so that the owner can make necessary arrangements to modify/protect existing structures from damages. 4. The contractor shall be responsible for notifying all utility owners, adjacent land owners whose property may be impacted and the Virginia Department of Transportation prior to completing any off -site work. 5. Contractor shall notify and coordinate all work involving existing utilities with utility owners, at least 72 hours prior to the start of construction. 6. Contractor shall immediately report any discrepancies between existing conditions and contract documents to the owner and engineer. 7. Contractor shall submit for the approval of the owner submittals of all specified materials listed in the plans, to include shop drawings, manufacturer's specifications and laboratory reports. the owner's approval of submittals will be general and will not relieve the the contractor from the responsibility of adherence to the contract and for any error that may exist. 8. All bare areas shall be scarified, limed, fertilized, seeded and mulched. 9. All trees, saplings, brush, etc. shall be removed from within the right of way and the drainage easements. 10. Visibility of all mechanical equipment from the Entrance Corridor shall be eliminated. 11. Retaining walls require separate building permits. 12. All water service lines, sanitary laterals, and sprinkler lines must be visually inspected by the Albemarle County Building Department from the main to the structure. 13. Accessible parking spaces, access aisles, and accessible route shall be installed in accordance with ICC ANSI At 17.1-09. 14. Where the flood level rims of plumbing fixtures are below the elevation of the manhole cover of the next upstream manhole in the public sewer, the fixtures shall be protected by a backwater valve installed in the building drain, branch of the building drain or horizontal branch serving such fixtures. Plumbing fixtures having flood level rims above the elevation of the manhole cover of the next upstream manhole in the public sewer shall not discharge through a backwater valve." 15. All roof drains shall discharge in a manner not to cause a public nuisance and not over sidewalks. 16. Buildings or structures built before January 1, 1985 must have an asbestos survey performed in order to apply for a demolition permit. Asbestos removal permits are required if positive for such from Albemarle County and VDOLI. Contact VDOLI for their additional requirements and permits for demolition projects and 540-562-3580x131. NOTES PER APPROVED ZMA201900001 1. Development of TMP 61-154B shall follow the approved Code of Development as part of ZMA201900001. 2. Section 4.16 of the Albemarle County Zoning Ordinance shall apply to all recreational facilities. 3. Signange shall be provided to prohibit vehicular traffic on private street in Block 2, except for emergency vehicles; or, bollards shall be installed. 4. Notwithstanding anything herein to the contrary, all non-residential uses shall be limited in height to one (1) story, or twenty-five (25) feet. Such uses shall also be limited to a building footprint of six thousand (6,000) square feet. 5. Porches, eaves and awnings shall be considered part of the structure and shall not extend closer to the street than the required setbacks. 6. Minimum building separation shall be required per Section 4.11 of the Zoning Ordinance. 7. Any primary residential structures in Block 1 shall face Belvedere Boulevard. 8. The applicable setbacks for Block 2 shall be measured from the edge of Amenity Area D. 9. Pursuant to Section 32.7.9.7, the parking areas along the northern and southeastern boundaries of the subject property are required to be screened. In addition to Section 32.7.9.7(b), see the Code of Development for appropriate screening options. 10. Dumpsters and Dumpster Pads on the Property shall be screened pursuant to Section 4.12.19. 11. The Applicant shall be required to provide onsite treatment of 25% of the required stormwater treatment. Such techniques of treatment shall include pervious pavers, micro bioretention, or other approved measures. 12. 15% of the total residential dwelling units within the project shall be Affordable Dwelling Units (the " 15% Affordable Housing Requirement"). The 15% Affordable Housing Requirement may be met through a variety of housing types, including but not limited to, for -sale units or rental units. APPROVED SPECIAL EXCEPTIONS The private street authorization for amenity -oriented lots in Block 2 was approved by the Planning Commision on January 14, 2020. In addition to the private street authorization, the following special exceptions were additionally approved by the Planning Commission on January 14, 2020: curb & gutter, sidewalk, and planting strip for the private street in Block 2. 999 RIO ROAD S D P202100009 TAX MAP 61, PARCEL 154B ALBEMARLE COUNTY, VIRGINIA VICINITY MAPSCALE:1°=500' �Srhnoumouse 1hrih Shop Oy,�cetn Gulf 19 Auto and Truck Doctor �pnons' m Q Car Lovers Rio 0 a4 °; "1.s ;p Covenant Church © � RIO ROAD E s s.J ,c a y V, a SITE _ City Church (Central) © \ 4^b d �4 a% �°O q .O yyp VAIIM'»k r e3 44J< CATFC V \ 4 �J, I 01 S � 410 a W Me,PgfF� aa,M "quy, John SHEETINDEX C1 COVER C2 EXISTING CONDITIONS C3 SITE PLAN C4 UTILITY PLAN C5 OFF -SITE SEWER CONNECTION C6 UTILITY PROFILES C7 GRADING PLAN C8 AMENITY & LANDSCAPE PLAN C9 SITE, VDOT & ACSA DETAILS C10 SITE VDOT & ACSA DETAILS C11 ACSA DETAILS C12 SITE DETAILS C13 MAINTENANCE OF TRAFFIC IMAGE PROVIDED BY GOOGLE MAPS SHIMP ENGINEERING LAND PLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM f [>,LTH pF O G O ,� U Hr,9TFhhJ1 14IMP a 45183 4� T. E�& I FINAL SITE DEVELOPMENT PLAN 999 RIO ROAD ALBEMARLE COUNTY, VIRGINIA SUBMISSION: 2020.05.26 [INITIAL SDP] REVISION: 2021.01.21 [FINAL SDP] 2021.02.22 [ARB] 2021.04.13 [ACSA] 2021.05.10 [ARB] FILE NO. COVER 19.006 C1 TMP 61-155 CHURCH OF GOD; EDGAR WAYNE ROBERTS; PETER CEFARATTI & REGINALD GATLING TRUSTEES 70041 DB 5134 PG 222 ZONE: COMMERCIAL OFFICE USE: PUBLIC 6.91 AC SDM c PJM H .. - 15' DI-3B FH — .. _.... W W —.W —W —W —W —W — ov Ww.� —w w Wrv~ w=W ';W —w —W W —"w w,—w 4 Wuw ,#75 ig a a BELVEDERE BEND. / VARIABLE WIDTH R/W �— — —T PH NEB / DB 3772 PC 366 , pox uc 15''.DI-3B IN. :75 - 463 -. CURB - / / �WV. . .. _^-..¢ - - — 42'09'12'� o LI --- —_ — — _— POL -.'<I�- � ,o • � POLE co / ;�R °GUY TREELlkk\E TO BE R MOVED IF Q24 WALNUT \ \ \ \ \ I FRAME (TBR) \ \ \ \ \ SHED (TBR) /S II (TBR) 30 HEMLOCK\ \\ \\ 80.5' \I \� TREELINE TOJB� MOVED e^k // \\ \ \ \ \\ BUILDING TO BE REMOVED I� WALNUT I 1 \ \ \ \\ \ (TBR) ym EX. DRAINAGE / ,i TING - I \ I ESMT'.DB 377. _ \ 5LF OF 15" / FRAME \ \ \ PG 36 / r VA 2 RCP TBR o SHED (TBR) ( \ \ \ \ / / / / / / / / ��'� yMIP \�J \ zz.s / \ BUILDING TO BE\ REMOVED m I �� / / / / — — / �0.WELL (TBR) / / \ \ TMP 61 1154E / ^/ ' I6 SIG / /""\ 471 �/ \ WINDMILL VEN�URES LLC �4 / ^ 10 COFFEE ° / / h / �. � O(TBR) `p'I � DB 4505 �G 218 RIO ROAD EAST N�. ou 4 / / / ` — ZONE: INEIGHBORH00� MODEL DISTRICT / / Hp® / / \` — — — / / / / / / lK VARIABLE WIDTH R/W m' I /) USE: SINGLE FAMI�Y RESIDENTIAL \ DB 3772 PG 366 Ni W �/ // 28.2 TBR) / I I 1.918/AC�� EX. RWSA UTILITY ESM I \ /� I / / //(TBR) DB 356'3 68 / / / FFE= 5.1 1 STORY OD RICK #999 (TBR) z FE=475.17 D I / (oB) GWD A ° WELL / / / / TREELINE TO BE REMOVED / / / / / HOUSE // / / / / / /// / // // 018 HOLLY z (TBR) 18 HE L K BUILDING TO E MOVED m f� FR2CME ARPORT (TBR)lol / BE C'HMARK ASPHALT \ \ k E-114 633a 4 (TBR) I \d/ / Q / ` l\ l SHIMP ENGINEERING2. LAND PLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM p,LTH O U Jusx11P a 45183 ��S'SIONAL E� FINAL SITE DEVELOPMENT PLAN 999 RIO ROAD ALBEMARLE COUNTY, VIRGINIA SUBMISSION: 2020.05.26 [INITIAL SDP] REVISION: 2021.01.21 [FINAL SDP] 2021.02.22 [ARB] 2021.04.13 [ACSAI 2021.05.10 [ARB] a - ROW DEDICATION: "r�,- APPROX. LOCATIOt`A a-.3,082 SFOF EDGE OF EXISTING - 6X6' LANDSCAPE EASEMENT C� -- - a - BELVEDERE BLVD. MULTIUSE PATH a VARIABLE WIDTH R W — oX_ Rip TELEPHONE NEW VARIABLESTORM BOX - `° DB 3772 P /RICK FACING WALLS 30T TO RIO ROAD 185 TO ENTRANCE 2 MILL & 05 RPER WPP 2 - 5, p�PN"C�NG 55 SH �SYP i BOX UG MANAGEMENT- ATER 1,230 SOUSE pA 6 HORIZ TAD / I All 6X6' LANDS./APE EASEMENTS jI c \.� ppUL OOD B ARD1 TMP 61-155 CHURCH OF GOD; EDGAR WAYNE ROBERTS; PETER CEFARATTI 8 REGINALD GATLING TRUSTEES 7pp4p DB 5134 PG 222 ZONE: COMMERCIAL OFFICE USE: PUBLIC 6.91 AC SDM� l WMH 15' DI-3B FH. W �W',�.W .—W.—W— WWV —W W bW% W W W" W —W —:W —W:—W.'�W- w —W —_ W W LLJ Q ` a a BELVEDERE BLVD. a VARIABLE WIDTH R/W DB 3772 PG 366 15' DI 3B CURB - INV. IN.-463.75 , �——OHU—OHU—OHU—OHU—OHU—OHU—tUTLTY °GUY ■. ' "' POLE I C2 f MINfMUM NEWL6' .d - IF X X X -.-3tl Y MIN UM 3' FRON BUILDING SE ACK d'" U Q EV x I x m LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 I d° I LOT 8 LOT 9 888SF 891SF 892SF 896SF 899SF 901SF 903SF x x 1,412SF 1,277SF I [ FFE 478 FFE 478 FFE 478 ❑ FFE 478 FFE FFE 478 FFE 478 I m FFE 478.5 FFE 478.5 W(IIR NEW 5' I El❑ 478 ° .� DOGH US� LOT 1-7 �' � l� MH ❑ ❑ ❑ MF UNITS x I x I I Al >EI El El ING 45• o 5/a WM d � VA IT 4,j _ X X z OW -OFF 1 SSEMBL l° -- -- ; a _te q_ - Pa _G9PE-SVC�° H_F LOT 10 1,334SF FFE 478.5 LOT 8-13 AFFORDABLE ATTACHED UNITS SE1gPCK LOT 11 1, 397SF FFE 478.5 LOT 12 1,406SF FFE 477.5 LOT 13 1, 80OSF FFE 477.5 NJ N SETBACK y/ I I A2. I "-'NEW MH 1 �� NE MH-1 8 SDR-26 I _ I - �dk C `" 15. �� T01476.62 s a = - `. _ '� TQP 47$. NV. OUT=4 O,o S 0 MTECH SC-31 INV. - HDPE�. INV. IN=472.13 Ci 1 [ I 44 RREE MINIMUM 1 DIP xBTEE 3/4" ORP x TEE 0 ID N 1 N I(TYP.)I s V�' W W 1 '" W W STO� TMP.) W W t c 4„ CRq N'" �' 8" DIP W I P z W IR 1" C RP 4® m A1A EW 10 STOP IN CA -2 = G RIO ROAD EAST I INV. — — V RIABLE WIDTH R/W ell VDo #3 STONE-4WV.. J�4;15 F DB 3772 PG 366 W W A16 I .. _ EX. RWSA -UTILITY ESM 45' _ , _ , , _ -- DB, 3563 PG 68 FITTING - NEW 24" NYLOPLAST DETENTION ACCESS. I N _ a INV. 463.65 (SUMP I A IN STRUCTURE) I N F D� I I I I I ♦� I g I it BE CHMA K I -� Imo I■�__ .:6l 4 d®ii.► ,,. r -�� _®Aa'll�� ME II MIN■ ■I no I i T ®BOA W 30 I PLASM 901 BE�1 ...:.. . .. _ _ A IN IN �--- -----II I 15" HOPE C3 NEW NE I MH 1 5'�Rb UILDTNC' I �NIM BACK — — —'1— — e U Z m d. w 0 <Z m LOT 14 LOT 15 LOT 16 LOT 17 LOT 18 m 2,111SF 2,098SF 1,970SF 2,106SF 2,41OSF FFE 480 FFE 479.5 FFE FFE 479.5 FFE 478 0 ° N 479.5 LOT 14-18 M iSFD 5 _ a a I < N 39. 0838: 8 - EW 6' I 15" -H P 81 EW 0" - E 114 3633.2T - I I-3B I L LAST - MINIM M 10' ELIE -468. 6 I DRAI - IRON ACK W - X X- 7CJ—= — —' X= _x X—____x' — X X X— X X X X 0 TCHLIN 5 D TI TMP 62F-E277 UTILITY- --_ ALBEMARLE EX,- VARIABLE.YVIDTH -" y -.-POLE. - -DB 4830 PG.-20�I I AGSA UTILITY-ESMT --__ _______ - BENCHMARK I' N- I EM VE EX. BLOW- F ASSEMBLY _ _ _ _ _ _ E-11493847.99 _ _ 5003 t N1 AND EXTEND 8" WA RLINE . NAIL TMP 62F2-X WV DUNLORA V LLC TMP 62F2-A DB 4717 PG 703 SHEPHERDS RIDGE AT ZONE: R4 RESIDENTIAL [ TMP 62F2-B / DUNLORA COMMUNITY USE: UNASSIGNED I I SHEPHERDSRIDGE ATDUNLORA / 1 F�WL RID I ASSOCIATION INC I 0.10 AC vT L J ,,:,.. I DB 5202 PG 778 — — — ROAD PAVEME 1 Em x x x x TMP I 62F-El ON NEW 0. / 20 40 . 66 ISO NEEDED FIRE FLOW DATA: TOWNHOMES ARE CONSTRUCTION TYPE V-B WITH 3000 SF MAX FLOOR AREA PER UNIT. ISO NEEDED FIRE FLOW = 1500 GPM AVAILABLE FIRE FLOW = GPM TBD SHIMP ENGINEERING LAND PLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 CHARLOTTESALLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM 7�p,LTH �O u JU' HIMP a IT 45183 K' SIONAL E�Ole ALBEMARLE COUNTY, VIRGINIA SUBMISSION: 2020.05.26 [INITIAL SDP] REVISION: 2021.01.21 [FINAL SDP] 2021.02.22 [ARB] 2021.04.13 [ACSA] 2021.05.10 [ARB] 9Ima►[el UTILITY PLAN 19.006 C4� / it X X N I O / _ MIN UM 3' F ON BUILDING SE 3ACK T c / EV x S 7s I \ \ l as I 4A�4\ / N � / I LOT 1 LOT 2/ LOT 3 LOT 4 LppT 5 \ LOT 6 LOT 7� - - LOT 8� II LOT 9 LO\0 LOT 11 LOT 12 LLO0T 13 888SF 89A/SF 892SF I 8965 SJ9SF 901SF \ 903SF x x ` - 1,412SF q,277SF 1,334SF 1,397SF 1,406SF /f,8OOSF "' / �h / FFE 478 F� 478 FFE 478 FFE 4 8 F E \FFE 478 FFE 478 \ a\ I A� _ m FFE/478.5 FfE 478.5 FFE 478. 8 FFE 478.5 FFE 477.5 FFE 477.5 °.a 4�8 V V I a \ o A LOT 8-13 o\ o / 1� / [ 4i ❑ ❑ MOTUNIT 1 \ \ \ 243\ I �' \ \ AFFORDABLE / z �� wrn \ x \ I x �- n \ ATTACHED E \ \ UNITS / mm VA - - - � I L I _a. p/ N -` - -- --- .<� I ---°al -° _ - a _.T__j � a ` I - � .. a .<\a. ° � \ � I UM 1 REA UILDI SE ACK / 7 �w / N nay 138 a 76w « 7777�. R s 7s 7s \ sw W wW W w W 71 I / ` \ i / 7v b m A 753 E 2.0 m mo a 7 r ° 'a .`. `1/I / �[ .,.. aka A 76 ^v I �53% ro 8. 1 74 / '7 79 13 AAP Mu ROAD EAST 6/ — --J --1 ---� — 7I °,� C/ / I / N 76, °4 m LOT 14 LOT 15 / LOT 16 LOT 17 > I _01 18 m 2,111SF 2,098SF 1,970SF 2,106SF / B I 2, 10SF .°. o FFE 480 / FFE 479.5 FFE I FFE 479.5 I FF4 478 / LOT S14-18 \ 479.5 >S m . ° 72 N 39. 0838. 8 I \ I „ , / - 77' 81 /� N�6 E 114 3633. T - I 73 7 76 76 72 x MINIM M 1 '> R BUIL ELIE -468. 6 75 - 78 / -IRON ACK W �., 71 �'X X—/� —' X— Df� —X X X� �L 3h X X X X X \ X 0 2 RW A WM TO BE ABANDONED D TI TMP 62F—E2 ✓. �s �� a ,�� A :[.III\I, • III\� I ■' x y � / x wP / / 62F-�1 I ALL/4EIGHT/4' o / 40 60 SHIMP ENGINEERING LAND PLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM 7�p,LTH U JUSHIMP a IT 45183 K' SIONAL FINAL SITE DEVELOPMENT PLAN 999 RIO ROAD ALBEMARLE COUNTY, VIRGINIA SUBMISSION: 2020.05.26 [INITIAL SDP] REVISION: 2021.01.21 [FINAL SDP] 2021.02.22 [ARB] 2021.04.13 [ACSA] 2021.05.10 [ARB] 91ma►[el GRADING PLAN 19.006 T_12-�CPSRIOARW"M"AG "IIA ENRD - -0- 14 pi �7 [ I tale: 1 "=20' W W U a _ _ _ _PHASE, 2 NON—RESIDENTIAL _ m I A I I D D • �I N I I� D a UA� Z z Z ' m I m N I `� 0 m n r I T / 7 AI �� T / . /0 ONE �. OEM ME ono ■I aaai MAN lir VB�.1�a ;W10 s.PEW 1: ♦-_ low 4 . , • -• .�/ o iix �•v itEremM.Eei2e VRIMf�I_ W AN •, sw '� LOT 2 LOT 4 LOT 5 LOT 6 LOT 7 1f LOT 12 �.. / • ,478 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12 LOT 13 1,412SF 1,277SF 1,334SF 1,397SF 1,406SF 1,80OSF FFE 478.5 FFE 478.5 FFE 478.5 FFE 478.5 FFE 477.5 FFE 477.5 LOT 8-13 AFFORDABLE ATTACHED UNITS QP Co A i ITTING GARD N ° x 615 Sr p .l Block 1 Amenity: Multiuse Path 3,761 SF Dog Park 1,120 SF Courtyard + 3,637 SF Provided: 8,518 SF* Required: 8,364 SF *Additional 2,447 SF to be provided with future commercial site plan for a total of 10,965 SF of amenity area in Block 1 Block 2 Amenity: Multiuse Path 1,427 SF Central Greenspace 6,945 SF Sitting Garden 973 SF Natural Playscape + 737 SF Provided: 10,082 SF Required: 8,276 SF LANDSCAPE SCHEDULE Plant Min. Total Canopy Total Symbol Planting Type Botanical Name Common Name Cal./Height Quantity Height(ft) SF Canopy in 10 Yrs SF ///DQp Large Deciduous Tree Quercus phellos Willow Oak 2.5" 6 31 370 2220 4 Large Deciduous ree Ulmus americans 'Princeton' American Elm 'Princeton' 3 4 25 397 1588 .5" Large Deciduous ree Celtis x occidentalis Hockberry 2.5" 6 30 572 3432 OAF Large Deciduous ree Acer rubrum "Armstrong" "Armstrong" Red Maple 2.5" 3 30 44 132 O G Large Deciduous Tree Ginkgo biloba "Princeton Sentry" 2.5" 5 25 20 100 Princeton Sentry" Ginkgo SI Medium Deciduous Tree Soph Rjaponica 'Regent" "Regent" Scholartree 25" 7 28 394 2758 0 Ornamental Tree Magnolia x soulangiono Saucer Magnolia 6-8' Ht. 3 10 145 435 Semi —Evergreen Shrub g Viburnum x utile 'Conoy' "Cono " Viburnum y 24" Ht. 23 4 18 414 Q Evergreen Shrub Distyiium x 'PIIDIST—II' Blue Cascade 24" Ht. 12 4 PPAF Distylium Low Maintenance Ground Cover TOTAL SF: 10665 CODE OF DEVELOPMENT SCREENING SCHEDULE Plant Symbol Planting Type Botanical Name Common Name in. Cal./Height Quantity Total Height(ft) Canopy SF Total Canopy in 10 Yrs SF f'�, ( j '�„/ Small Deciduous Tree Acer campestre Hege Maple 5-8' Ht. 7 19 230 1610 Ornamental Tree Cercis conadensis Eastern Redbud 6-8' Ht. 4 17 124 496 Screening Evergreen Cryptomeria japonica 'Yoshino' Cryptomeria 4-5' Ht. 3 20 123 369 TOTAL SF: 2475 LANDSCAPING REQUIRED: SITE REQUIREMENT (SEC. 32.7.9.8): 15% CANOPY REQUIRED. -\ SITE AREA: 1.918 AC (83,548 SF) 11X6' LANDSCAPE SEMEN 83,548 SF x 15% = 12,532 SF CANOPY REQUIRED: 12,532 SF CANOPY PROVIDED: 10,665 SF + 2,475 SF = 13,140 SF ENTRANCE CORRIDOR STREETS: LARGE SHADE TREES (2.5" CAL.) - 35' \> Co O�c O.C. WITH INTERSPERSED ORNAMENTAL TREES, 190 LF OF FRONTAGE : 5 LARGE SHADE TREES PROVIDED: 5 LARGE SHADE TREES W/ 3 ORNAMENTAL / INTERIOR PARKING AREA (SEC. 32.7.9.6): 5% OF THE PAVED PARKING AREA & 1 LARGE OR MEDIUM SHADE TREE PER 10 PARKING SPACES 21,346 SF x 5% = 1,067 SF RED: 1,067 SF .� PROVIDED: 1,124 SF 48 PARKING SPACES PROVIDED RED: 5 LARGE SHADE TREES PROVIDED: 5 LARGE SHADE TREES 20 0 20 40 60 INTERIOR PEDESTRIAN WAYS: MEDIUM SHADE TREES (2.5" CAL.) — 25' O.C. PROVIDED: 15 LARGE SHADE TREES Scale: 1°'=20' NOTES: 1. All site plantings of trees and shrubs shall be allowed to reach, and be maintained at, mature height; the topping of trees is prohibited. Shrubs and trees shall be pruned minimally and only to support the overall health of the plant. 2. All landscaping and screening shall be maintained in a healthy condition by the current owner or property owners' association and replaced when necessary. Replacement material shall comply with the approved landscape plan. 3. All new planting shown on the plan will be completed after building and road construction to avoid tree planting damage. 4. All disturbed slopes 3:1 or steeper to have low maintenance ground cover. 5. Any existing tree proposed to remain shall be replaced in kind if negatively impacted by improvements associated with this project. SHIMP ENGINEERING LAND PLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM p,LTH o—,� to ��S�� v JUSTT 1R3 HIMP a U9. 45183 K' SIONAL FINAL SITE DEVELOPMENT PLAN 999 RIO ROAD REMAINING BACKFILL SHALL NOT CONTAIN ROCK MATERIAL 36"MIN LARGER THAN 5" IN ANY DIMENSION 24"MI INTIAL BACKFILL* 8"MIN (6" LIFTS) EMBEDMENT * THOROUGHLY COMPACTED SPRING LINE BY HAND OR APPROVED OF PIPE O MECHANICAL TAMPER HAUNCHING NO. 68 STONE - BEDDING 6" max 4" min FOUNDATION (SHALL BE REQUIRED WHEN SOIL CONDITIONS ARE UNSTABLE ALL PIPE) NOTE 1. OPEN CUTS IN PAVED AREAS WITHIN EXISTING VDOT RIGHT-OF-WAY SHALL BE BACKFILLED ENTIRELY WITH NO. 21A STONE. 2. FOR DUCTILE IRON PIPE THE BOTTOM OF THE TRENCH SHALL BE SCRAPED AND COMPACTED, AND ALL STONES REMOVED OR A 4" BEDDING OF NO. 68 STONE SHALL BE PROVIDED 3. WHERE ROCK IS ENCOUNTERED PIPE SHALL BE INSTALLED ON A MINIMUM 6" BEDDING OF NO. 68 STONE TYPICAL SEWER PIPE INSTALLATION IN TRENCH N TS FIG. S-3 ACSA: SEWER PIPE INSTALLATION (TYPSEWER PIPE INSTALLATION ) C9 NOT TO SCALE I I I I I RRADUS TO BE AS I yy�I Al >: STREET APPROACH SAE SURFACING I GENERAL NOTES AS MANLME ROADWAY (SEE MOTE fit SHOWN ON RAN31 9 C C _ _ _ _ _ _ _ 1 _ I t. WHEN CO-TI 6 USED FOR STREET CONNECTIONS THE CONNECTION MUST BE DESIGNED IN ALCDRDWa WRN T 1 fMX,S To BE AS AASHTO POLICY AND THE APPLICABLE REWRETENTS / RIDIL COMBINATION SHOWN ON PLANS) CURB AND °UTTER DOF T pROETAD'SMN CRAWL. NCLUDIMG ^+ION( ISTANCE / +P CPR, ( NOTE 7) I 2- WHEN THE ENIRWCE MR CANNOT ACCOMMODATE THE TLIRMD SEOW MS OF ANTICIPATED HEAVY TRUCK - -21' WWW 1RAFC THE DEPTH FOR SIDEWALK 6 CURS RAPS fHE SIDEWALK I (SEE MOTE 2) 8' I OPTIMAL g•• WITHIN LINTS DI 11E RIDI SMLLO FO NDIEM4D TO I ROW LINE-� 3. WHEN USED N COILLNCTBIN'MH STANDARD CO-3 --__ I OR W-] THE CUPS FACE ON THIS STANDARD IS TO TO TIE ENPAxSIOx Jp(i EXPANSION 1a JOINT BE ADJUSTED MATCH MOUNTABLE CURE CONFGRATON. W 4. SEE STANDARD CO-Q FOR CUR RAMP DESIGN TO BE NOTE:MOTH "B• 2'-0" 011 AS MAINLINE ROADWAY SHOWN ON TYPICAL SECTION. A -I USED MH THIS STANDARD. 5. OPTIONAL FLOWLBIE MAY REGIME WARPING OF A PLAN VIEW PORTION OF GARTER TO PRECLUOE POO4IHG OF WATER. ENTRANCE NOTES 4AVLWE ROADWAY SLOPE 6. PLANS ARE TO INDICATE WHEN CONSTRUCTION OF A FLOW D'PMABUIO CURVE LINE 6 REGO RED TO PROVIDE POSITIVE DRAWHM{ ACROSS DER OR OPTION& FLOW LINE 8%SEAL MORE CHANCE ® -- D TIE ENTRANCE. ]. "MENE PAVEMENT SNAIL BE CONSTRUCTED TO THE R/W LINE (EXCEPT MY SIIBPRADE STA ZAIM YAFILNE ROADWAY - - - _ - - - _ - REQUIRED FOR YARROM PAVEMENT wHKH CAN BE e% MM. p OMITTED N THE ENTRAMCEJ SLOPE CAGE ® _ _ 6. RADIAL CLP6 OR COMBINATION CURB AND WTTER D THE R/W LINE EXCEPT FOR RERLACEM�ENT PURPOSES. 20• WYIY FOR 9. THE DESRMLE AND YAXIMOV ENTRANCE GRADE CHNKES 5'IK COMMERCIAL ENTRANCE TABLE.ETHEM VALUELISTED IN S ARE NOT APBLE PLCASSEE TO STREET CONNECTIONS. M CONSTRUCT GAME CHANGES WITH A PARABOLIC CURVE. SECTION A - A ALLOWABLE ENTRANCE GRADE CHANGES B i. Y•a' -- ENTRANCE VOLUME GLIDE 'd' CHANGE DESIRABLE MAXMM HIGH YORE TRAM 1500 VPD 0 % ] % MEOW 500-1-Ap YPo s 3 % 6 % LOW LESS THAN SEND VPD WB% Ill NDTE. '�• 'N' '•' ALLOWABLE ENTRANGR CE ADE TABLE 6 ROT CL/SS)N w •4 .• APPLICABLE TO STREET COMECTIONS CONCRETE SECTION C-C MCIFICAITIONMETHOD OF TREATMENT - CONNECTION FOR STREET INTERSECTIONS ANSPORTATION ws ANDYIRGROACOMMERRCIALMENT HENTRANCES 2�VDOT: METHOD OF TREATMENT C9 NOT TO SCALE 1/f SECTION CAST SIGN 7- 1/A SECTXN STEEL NOTES 7- m LUGS TO BE T-31 L 2%+" A r/f" A H/� CAST III N D'-4" LONG 1. DEPTH E" jNE. FOR DEPTHR THAN AN 'USE LL 4A A 00N T STANDARDWA OPTIONAL c' BRACE RBS m 4'- " :6't a 2. THE "H' DMENSDN SHOWN ON ON THE ND STAARDS AND SPECIFIEDTHE PLANS WILL SE MEASURED FROM THE INVERT OF NE WELDED THE OUTFALL PPE TO THE TOP OF THE OINT STRUCTURE. PLANw- DIMENSIONS Al1E APPROXIMATE ONLT FOR ESTMATINIG WELD ALL PURPOSES AND THE ACTUAL Dq.EH6ION5 CONNECTORS SMALL BE DETERMINERS BY THE O COLLAR CONTRACTOR FROM FIELD CONDITIONS. 3. WHEN SPECFBD ON THE PLANS THE ADVERT 6 TO BE SHAPED N ACCORDANCE WITH STANDARD 6-1. THE COST OF FURNISHING AND PLACING AIL MATERIALS INCIDENT& TO THE SHAPING IS TO BE RPIIDED N THE BID PRICE FOR THE PLAN '/y • 11/i' • 4"J %i' A 4" STRUCTUE. UD SHEAR (ORATE REMOVED) LUGS IZ" 91/i' CONNECTORS 4. 4. N THE EVENT THE EVERT OF THE 01 PPE MS HIGHER THAN THE BOTTOM OF THE STRUCTURE. THE INVERT ffiy5EEE .L A OF THE STRUCTURE SHILL BE SHARED WITH CEMENT MORTAR TO PREVENT - SECTION B-B STANDING OR POIDING OF WATER N THE COLLAR DETAIL I i, NN RAISED �ETTE6NG STRUCTURE. THE COST OF FURNISHING TTODA ET NSHAPINGMISTTOAHE INCLUDED 21 IN THE BID PRICE FOR THE STRUCTURE. NS FORD NCI WASTE DEANS TO WATERWAYS CAST ON ONLY 5. STEPS ARE TO BE PROVIDED WHEN N IS 4•.0.. OR GREATER. FOR DETAILS SEE STANDARD ST-1. DETAIL B DETAIL A 6. �LI� MAY BE PRECAST OR CAST - HARDWARE 2 6'. 7. W 4 K W' SMOOTH TOWELS AT CLOTH 1'-3• SEE FOTAIL B APPROXIMATELY 12" C-C TO 8E I y PLACED In ALL MEAs MJALENr BERM, MCA. 1 TO ABUTTNG CONCRETE TO PREVENT FBa 070 OR SETTLEMENT. IN LIEU OF DOWELS 48 s 8" WIDTX Ingo Q� A 2"M4" NOTCH WAY E PROVIDER. n SEE STANDARD T-0-3.4 FOR D, COLLAR - 3• dLETER LTERNATE DESIGN. C9 ir,N S� NOTE'E8 S. THARDWAERPE PLASSTIICC CLOTH vi' MESON" Si ]i 1$' OR GLVANZEO STEEL WEE.M M 12"-6"-B" ON 24" CLOTH RED Ain in ����������� HARDWME ANCHORED FIRMLY nA rn D . p .D SEEE -T 1 SIB IIEIII������0 1 9. TO THE OUTSIDE OF THE STRUCTURE. CAST LAS M PLACE CONCRETE 6 TO BE t3000 A D, DETAIL 8 'YF.IB TE CONCRETE IS TO BE 4000 PS. CONCRETE BE 00 FOR. 1/i' SECTION A -A '•-I L Y' JJL� r ' � L1' -V- - Z" �4I,-,�� B. MY ALTERNATE IEMODS OF ANCHORAGE MEETING THE APPROVAL OF THE ENGINEER CONCRETE QUANTITIES FOR MRJ. DEPTH MAY BE SUBSTITUTED FOR THE CAST IRON t2" CONCRETE PIPE - L440 CU. YD. CONCETE 15" CONCRETE PIPE - 1.528 M. YD. CONCRETE I/•' �� APWRO%MATE WEIGHT Y� CAST IRON It. LUGS AS SHOWN HEREON. DUMP MO WASTE DRAINS TO WATERWAY B'• CONCRETE PPE - WO M. YD. CONCRETE GRATC J63 _ IB UTS LETTERING 6 REQUIRED ON Ll q-1 CONCRETE PIPE - L817 CM YD, CONCRETE SECTION C-C SECTION D-D VARY GRJUE BTLMANUFACTURER, TTEPNG MAY ADD ADDITIONAL TONNAL FOOT OF DEPTH. GRATE DETAIL STANDARD DROP INLETNR�R 1211 - 24" PIPE: MAXIMUM DEPTH (H) - 10' 233 R 104.01 VIRGINIA DEPARTMENT OF TRANSPMTATM J02 6.1 < NDTES� SHARING OF MANHOLE AND INLET INVERTS IN ACCORDANCE WITH THIS DRAWING 6 TO APPLY TO THOSE STRUCTURES SPECIFIED ON PLANS OR WHERE INVERT OF PIPE IS ABOVE INVERT OF STRUCTURE. t HANDLE OR DROP INLET IS TO BE FORMED ND CONSTRUCTED IN ACCORDANCE WITH APPLICABLE STANDARD OR SPEC DRAWING. THE INVERT SHAPING AS DETAILED HEREON 6 TO CONSIST OF A CLAW Cl. EXCEPT TCONCRETEW OFNCOAG��GREGATE WAY BE � IP TO 4- IN DIAMETER AND CONSIST OF STORE, BROKEN STICK, BROKEN CONCRETE OR BROKEN CONCRETE BLOCK. HE SUIFACE SHALL BE LEFT SMOOTH BY MEANS OF HARD TROWELLING- NOW OF THE COMSE AGGREGATE SHALL REMAIN EXPOSED � SLOPE TO DRAIN TO INVERT OF OUTLET PIPE SECTION A -A METHOD OF TREATMENT IN DROP INLETS SLOPE TO DRAIN TO INVERT OF OUTLET PIPE DETAILS OF INVERT SHAPING AS SHOWN HEREON ARE FOR EXAMPLE - [ • • : I PURPOSES ONLY. EACH ARMHOLE OR DROP (NET 6 TO SE SHAPED INDIVIDUALLY TO FORT FIT THE PARTICULAR INLET AND OUTLET CONFIGURATION AND FLOW LIKES. SECTION B-B PLAN METHOD OF TREATMENT IN MANHOLES \Vary STANDARD METHOD OF SHAPING SREFEREET ROAD ND BRIDGE STANDARDS REFEREE SHEET 1 OF 1 REVISION GATE MANHOLE & INLET INVERTS 302 108.08 NRCJBA DEPARTMENT OF TRANSPORTATION 4 MANHOLE & INLET INVERTS C9 NOT TO SCALE 01-7, 7A 79 DETAILS OF CONCRETE COVER AND GRATE f B DETAILS OF GUTTER AND 2• pMIEFER BAR R IOBe LBS./FT. LO W. To Suer s)m BE 0 z) NOTES METHOD OF PLACEMENT LBS/FT., <ABTN MB, MADE 60. 1. GRATE A S TO BE UTILIZED M + TEA LOCATIONS NOT NORMALLY NOTES J SUBJECT TO H/FFIC. 2. GRATE B IS TO BE UTILIZED IN 1. DI-) NO GUTTERS. LOCATIONS NORMALLY DI -)A NO CUTTER IN ONE DIRECTION. SUBJECT TO TRAFFIC. DI-7B GUTTER IN BOTH DIRECTIONS. 011 A 2. JOINTS BETWEEN METERS AND CONCRETE COVER 1 J. FOR DETAILS OF LOAD CARRYING ME i° BE DOWELED MH W % 8" 9.100H J� /=, % 4„ L2"%Y'%j'j' GRATE (GRATE B),ME T-d-), RMS 6 MPRO%. YZ" C-C TO PREVEM SETTLE - STUD STEM L21/i"X2Yf'SD/N. SHEET 103.08. MEN PMOINN ff OF DOWELS A 2" X 4+ NOTCH MAY ° CONNECTOR DETAIL A 4. CONCRETE COVER AND GRATE SEE STANDARD T-01-3, 4 ALTERNATE DESIGN. ME TO BE FURNSWD AS A MATE TYPE SINGLE UNIT. OUTSIDE 3. VARIABLE 2'1 OR PUTTER �B I OR II IR5X5'-0" BARS DNENSXNS OF %RATE TO PLAN VIEW GFROX PLANS) (12 REOT.) I - OR 3=4" % 2=DJ," (GRATEBE RE A' 4. DITCH GRADE MUST BE ADJUSTED TO REEF DIFFERENCE IN ELEVATION. SEE LONGITUDINAL SEE DETAIL ' + S. ALTERNATE METHODS OF SECTION. _ ANCHORING ANGLE ANON WILL BE 5. F DEPTH (D BECOMES LESS THEN 4" LENGTH ACCEPTABLE IF APPROVED BY THE OF WINGS ME TO BE EXTENDED AS dHRECTED SECTION A -A ]%" 1 " ENGINEER. BY THE MOWER. SECTION B- 6. GRATE AND DOLLAR ARE TO BE 6. CURTAIN WALL TO BE LOCATED AT THE END OF CRATE M GALVAMED. THE PAVED DITCH SECTIONS OF THE DI-7A L BM SPACING CHART 7. CONCRETE COVER MAY BE MANAGE. APPROXIMATE ARE NOT IBUTTEO BY OTHER APPROXIMATE OUANTRIES AT8 CILQLSON PRECAST DIN CAST M PLACE. CONCRETE RDKONCING TYPE A D B. CONCRETE TO BE CLASS M IF C,LST 7. F NORMAL DITCH GRADE IS TOO RAT TO ALLOW CLASS P3 STEEL IN PLACE. 4000 PSI IF PRECAST. FOR ADJUSTED GRACE TO MET A SPECIAL Od23 C. Y. 63 CBS. 2 S CANTER DETAIL WILL BE REOUIRCD ON PLANS. = 1• T 9. GGRRAONTE FLB S TO BE PANLLEL TO 2'ror�-�y1-o' SECTION A -A SEE NOTE NOTE lSEE NOTE 3 SfE NDTE BOTH SLOPES FLAT ONE STEER SLOPE A IXE INTERIM ATE SLOPE M I DRGM FIEF \ 1'roa - INLET BALK LP FORM diLH GUTTER GRADE TO BE PROVIDED J I _ p I = N1R6TFD TO MEET AS DIRECTED BY THE " 1 'T INLET ELEVATION ENGINEER 0-7A ORY). TYPICAL ELEVATION SEE NOTE 3 L.R. NOTE � N0MAL d1c1R,�"DE AN SEE TE 4 SEE NOTE 3 ,1 AIR FLATTEIR ONE STEEP SLCPE-ONE MT SLOPE BOTH SLOPES STEEP APPROXIMATE QUANTITY FOR CIE CURTAIN WALL, LOWITUDNL SECTION MEASURED FROM BOTTOM OF BUFFER (WHEN FILET B LOCATED ABOVE NORMAL DITCH GRACE) CONCRETE CLASS AI 0."'M. YDS. SEE NOTE 8. \VDO'F SPECIFICATION ROAD AND BRIDGE STANDARDS STANDARD MEDIAN DROP INLET REFERENCE SHEE7 2 OF J REVISION DATE 12" TO 42" PIPE z4, IOI.T3 YR41FA DEPMTMEM OF TRASPO TATION 503 APPROXIMATE WANTITIES CONCRETE DI-7 OaA dab CLASS u (M. Y05.) NONE 1.211 2148 �VDOT: STD. MEDIAN DROP INLET (DI-7) C9 NOT TO SCALE VI1 * COVER A A,. ❑ ❑ O`Z CONDITONS ❑❑ ❑❑❑1) A E❑❑ILETTERNG❑❑❑ ❑ ❑❑❑❑❑❑❑"�LWLOS. N' PLAN Tz�DIA AAA SECTION A -A i 1" YACHNfO 24'A" DIAL r COVER B zz)"Du - TRAFFIC Q ❑ = CONDITIONS MACHINED //.❑❑�Q❑I'\\ a: A A O r❑F-'11�.� I❑'1 I) \1 A m I m l UTTERING 11 /qw r0.11� Ly ' 11 El, N"dA \�❑dbd / �• APPROX.WIGHT Ili ❑� D - COVER DS LBS. ± ri '-- FRAME TOP OTHER COVER A OR B MAY K USED WON FRAME. MPROX WEIGHT 2Y' CIA 1.* COVER 90 1B5. ± x N 4ACMED SECTION A -A SHEET 4 a s BOB([ STANDARD MANHOLE FRAME AND COVER 224 302 VIRGINIA DEPARTMENT OF HANS'ORTAOM REV. )/02 De.a 6 VDOT: STD MH FRAME & COVER C9 NOT TO SCALE CG-6 NOTES: 1. THIS ITEM MAY BE PRECAST OR CAST N PULE. L CONCRETE TO BE CLASS AT IF CAST N PLACE. 4000 PSI IF PRECAST. 3. COMBINATION CURB 6 CUTTER HAVING A RADIUS OF 300 FEET OR LESS (ALONG FACE OF CURB)SHALL SE PM FOR AS RADIAL COMBINATION CURB A WTTM. 4. FOR USE WITH STPBLIM OPEN -GRADED DRAINAGE LAYER. THE BOTTON OF THE CURB AND GUTTER BE CONSTRUCTED PARHLEL TO THE SLOP SUBBASE COURSES AND TO TIE DEPTH OF THE PAVEMENT. 5. HLCWABLE CRITERIA FOR THE USE OF M-6 IS BASED ON ROADWAY CLASSIFICATION AND DESIGN SPEED AN N M SHOWN PF3ID1% A /^_I �2° R OF THE VOOT READ DESIGN MANUAL. e'• ' r•:r • D D D D • D 1'-1" ,- AD • • D D D D D. ---2 _ THE BOTTOM OF THE CURB AND GOITER MAY BE CONSTRUCTED I THE SOPEOA U- B• BIIRBASELCOTO URSED MINIMUM DEPTH OF T' I 5 MAINTAINED. THIS AREA MAY BE CONCRETE AT TIE OPTION OF THE CONTRACTOR V COMBINATION 6" CURB & GUTTER 502 REV.9/06 VIRGINIA DEPARTMENT OF TRANSEORTATION 201.03 VDOT: CG-6 NUI IU KALE DI-3A M, 3C EXPANSION KEYED EXPANSION JOINT 3'-10" FOR DETAILS OF INLET JOINT COAST, BARS = APPROACH FRAME N COVER BACK OF SIDEWALK s JgNT ^fGUTTER SEE STANDARD IC-2. " BARS G BM G OFFER 4•• •• 2" v) ro� GDTTER WAR m 2„ BARS C BARS B o GUMBASE HADWARE GL.Tj-�.- MS F SWEEP E PW', 6 yU\ w 110 11� , ;.-D.. 6. MIN. PLAN SECTION A -A MIN 1 'MAX. 10' MAX, F- A L-VARIABLE - MA%. 20' (' KEYED COAST. JOINT PUMPED P 2'.0" 8' 2'-8" S. ..C.. 2.. 11 GUTTER B Z BARS A WTHORMH W 1_ ____ _ ... 1•' B S C E BOBS F BARS E LAB :v roiM3" DIAMETERBARSE WEEP ROLE FRONT ELEVATION BARS F Burs B - - (GUTTER REMOVED) R• 6„ 1,. Sxyf BENT PLLl ATE a SECTION B-B IR TYPE a rv09E DETAIL SHILL BE USED WITH CG-3 M CC-7 STANDARDS, / R L2% X2'/2"Xy" TYPE B HOSE DETAIL SHALL BE USED WITH CG-2 & CO6 STANDARDS, GALVANIZED TYPE A TYPE B TO X 4" STIR SHEAR CONNECTOR WELDED GALVANIZED PLATE FOR TYPE A TO BE BENT ON AN ANGLE OF 68.30' TO ANGLE RON AT 2-C-C. CONNECTORS AND IS TO AT ANCHORED WITH %' x 4" STUD SHEAR NOSE DETAILS WELDED TO BENT PLATE AT rC-C, 2" W. PAVEMENT 01-3A �L ,� DI-36 L 01-30 - -WARPED PAVEMENT IAI z� FLOW _ _ _ _ FLOWw 1.-C.. 1 DETAIL WHEN USED FOR USE ON GRADES ADJACENT TO CURB FOR USE IN SAGS WITHOUT GUTTER BOTH SIDES TO BE SYMMETRIC& \VDOT SPEORCATION ROM AND BRIDGE STANDARDS STANDARD CURB DROP INLET REFERENCE 12" - 30" PIPE( MAXIMUM DEPTH (H) - 8' SHEET 1 OF 2 REVISION DATE 233 104.09 05/10 VIRGINIA DEPARTMENT OF TRANSPORTATION 302 ::8:�)VDOT: STD CURB DROP INLET (DI-3B C9 NOT TO SCALE D r' R D.G-F' . .!,D!,: SURFACE AM D.�AD,A ..e,..o.. SASE I I SUBBASE NOTES: 1. THIS ITEM MAY BE PRECAST OR CAST N PLACE. L CONCRETE TO BE CLASS M F CAST N PLACE.4000 PSI F PRECAST. 3. MIND HAVING A RADIUS OF NO FEET OR LESS (ALONG FACE OF CLROT WILL BE PAID FOR AS RADIAL CUR. 4. THE DEPTH OF CUB MAY BE REDUCED AS RICH AS 3" (W BERMS OR *INCREASED AS MUCH( AS 3- (S' DEPTH) N ORDER THAT THE BOTTOM OF THE IXWR WILL COINCIDE WITH THE TOP OF A COARSE OF THE PAVEMENT SUBSTRUCTURE. OTFERNg. THE DEPTH IS TO BE M• AS SHOWN NO ADUSTII NT N THE PIECE BE IS TO BE NAPE FOR A DECREASE OR AN INCREASE IN DEPTH. 5. CG-3 6 TO SE USED ON ROADWAYS MEETING THE fEOUIREHETITS FOR CG-) AS SHOWN N APPENDIX A OF THE VDOT ROM DESIGN MANUL N THE SECTION ON GS UIRAN STANDARDS. 6. WHEN THIS STANDARD IS TO BE TIED INTO EXISTING SAPPER CWB, THE TRANSITION IS TO BE MADE WITHIN TOOK THE MANGE N STANDMIS CAN BE MADE AT WGUAR OPENINGS, XV°Crr STANDARD 4" CURB OM sPEFERENCE REFERENCE ROAD AND BRIDGE STANDARDS VIRGINIA DEPARTMENT OF TRANSPORTATION Wri 502 SMUT I OF I REVISION DATE IOL02 VDOT: CG-3 NOT TO SCALE SFF STADARAD SL-I FOR APPLICABILITY OF SAFETY SLABS. B STANDARD MH-1 NOTTHE TIE i0P OF MASONDY IS TO BE LEFTER 1 FRAME M COVER SUFFICIENTLY LOW. TO PERMIT PROP L ADJUSTMENT OF COVER AND FRAME TO GRADE BY HE USE OF MORTAR OR = BRICK AS DIRECTED BY THE ENGINEER. 2 -d v b n T 1 •• 6" o FLAT SLAB TOP AS DETAILED ON STANDARD T-MH-2 MAY 8) 1 SUBSTITUTED FOR TAPERED O SECTION WHEN APPROVED BY - ••'. THE ENGINEER, ST-D. ST-I AM' .f" e.. - 6�A - DIAMETER=4'-8'V (2 + WALL THICKNESS) h SECTION B-B BRICK CONCRETE OR CONCRETE BLOCK 45- HALF PLAN VIEW HALF SECTION A -A (WITH FRAME AND COVER REMOVED) BRICK CONCRETE NOTES L OUANTITIES SHOWN ME FOR MANHOLE WIHDJT PIPES. THE AMOUNT DISPLACED BY PIPES MOST BE DEDUCTED TO TABLE OF OUMTITIES DEPTH BRICK MANHOLE CONCRETE MANHOLE BRICK CONCRETE CU. FEET THOUSANDS No.m YARDS CU.437 4 0.7 0.785 1.13] 5 OJ 0.785 1.699 6 OJ85 1.961 T 1.0 1.2 0.785 2.22J B 1.4 0.785 2.48 9 U 0.785 747 2.74) 11 1:8 0.970 3,455 11 19 0.970 3.417 12 2.5 3.81> f3 2.5 DOOR 0.970 4."9 l4 23 0.9)0 L5L 15 a.1 0.970 490J 16 D9]O 5.285 17 e_p 1 3 6.032 INLREVE\i p.582 OBTAIN TRUE WANITTIES. 2 A BASE THICKNESS OF 9" WAS USED IN COMPUTING CONCRETE GUANTITIES. 3. INCREMENTS TO BE ADDED FOR EACH ADDITIONAL FOOT OF DEPTH. 4, MATERIALS MAY BE BRICK, CONCRETE OR APPROVED CONCRETE MANHOLE BLOCK 5. IF BLOCKS ME USED THE MNFAUM THICKNESS OF SAME IS TO BE 5- OTHER TMCKWSMS ME TO CONFORM TO WALL THICKNESS SHOWN FOR CONCRETE. 6. ALL CONCRETE TO BE CLASS A3- 7. WHEN SPECFEO ON PLANS HE INVERT IS TO BE SHARED IN ACCORDANCE WITH STANDARD IS-i. THE COST OF FURNISHING AID PLACNL ALL MATERALS INCIDENTL TO HE SHMING IS TO BE INCLUDED IN THE B0 PRICE FOR THE STRUCTURE. 11 SPECIFICATIONIDOT REFERENCE MANHOLE FOR 12" - 48" PIPE CULVERTS ROAD AND BRIANDA 302 VIRGINIA DEPARTMENT OF TRANSPORTATION REVKIDN DATE SHEET 1 Or ! 04"0 106.0RGS 10 VDOT: MH-1 DETAIL C9 NOT TO SCALE DD-2 WTE51 I. THIS REM MAY E PREMT OR CAST N RARE. 2. CONCRETE TO eE CLASS U F CAST N RACE. 4000 PS F PRECAST. 3. CUR HAVING A RADIUS OF 3M AFT. OR LESS MONO FACE OF CURB) WILL FE PAID FOR AS RADA CURB. 4. THE DEPTH OF CURB MAY BE REDUCED 4 WON AS 3" HS" TEAT. OR INCREASED AS MUCH AS 3" CO' DEPT. N ORDER THAT THE BOttOM OF CURB WILL MINOU WIM THE TCP OF A COURSE OF THE PAVEMENT SUBSTRUCTURE. OTHERRSE TIE DEPTH IS TO SE W AS SHOWN. W ADJUSTMENT N THE PACE "' 6 TO BE MODE FOR A DECREASE OR AN "MAN N DEPTH. R 5.CG2 6 r0 FO USED ON ROADWAYS MEETING ME REQUIREMENTS FOR WAR AS S WARN N NRVDD A OF M VDOT ROAD DESIGN MAINUI e. -A I :i•:i - •I•A•:i• SURER" BE mix 4 :6- :'A om i A. i .0; A.:e I I sun= WEtl1CA1XN QE4G STANDARD 6" CURB 502 VIRGINIAFOPMTYENT OF TRANSPORTATION V. 9/O6 20L01 VDOT: CG-2 NUI IU SUALE GI-Z.2A 27Y4" MIN - 28Y4' MAX RAIL HEIGHT 3'-tv., N K 1�?).^laV O`NN. 1R' igMNJA" NNN .PNNN Art J IJ J J J J J GR-2 GR-2A W-3- POST SPACIWI t3'-F/i POST sPACMG) NAM DYNALC DEFLECTION • N MAX DYNAMIC DEFLECTION • 2' NOTES: AMORAL LOCATIONS SHOWN ON PLANS AM APPROXMATE ONLY AD CAN BE ADJUSTED CUIWIG CONSTRUCTION IF AND AS DIRECTED BY THE ENGINEER. FOR DETAILS OF POST AND BAgGUUTS SEE SHEET NO. SOLOS. • US NONL NOTED S RI. • USING NESTED SARI. OPTIONL IP-2A METHOD 0NB ADETAILS OF PAR ELEMENT. AND I RKOBACt OF POST ABSSOgRATED HARDWARE SIDE SHEETNOS. 501.01 AND 901.02. A WHEN NESTED RAN. OR ADDITKNL RAL 6 PLACED ON BACK OF POST RAIL ELEMENTS ME FURNISHED SHOP CURVED FOR RAN FOR M-2A THE MST SPACING WILL K W-3'. BETWEEN 5 FEET AND 150 FEET. ALL MMDRAL POSTS SHALL BE SET PLUMB. POST SNAIL NOT BE SET WITH A VARIATION OF MORE THAN /R- PER FOOT FROM VERTICAL. W-SEW, BLOCKMTS. AND POSTS SHALL BE SET AND ALIGNED WITHOUT ALTERATION OR FORCE. AS PER SECTION So, Or THE SPECFICANDAS. ALL GR-2 AND DR-2A RAIL SHILL BE MAINTAINED AT A STANDARD DI 3)M" ANN - 28iS" MAX AS MEASURED PER StANDAPp M-M. ALL W-BEAM RAMS SNAIL BE LAPPED N THE DIRECTION OF VEHCUAR TRAVEL FOR THE FINISHED ROADWAY. THE OPTIMAL GR-2A METHODS OF NESTING THE RAIL OR USE OF AN ADDITIONAL RAIL ON THE BACK OF THE POST FOR STANDAJD M-2A SHALL FO APPROVED By THE ENGINEER ANION TO INSTALLATION. FLARE RAPES DESION SPEED NLDE SHY LINE BEYOND SHY LINE YPH INC LS GLARE RATE FLARE RATC )0 9' 30+1 61 SO 8' 26,t Mn 90 6.9' 2N1 RH 40 30 4' 131 TI • SUGGESTED MAXINWM rLME RATE FOR SENRDO BARRIER SYSTEMS. \VOC]T A COPY OF THE ORCNL SELED AND SMNCO BRAWING 6 ON FILE N THE CENTRAL DEICE. SPECIrICATI ON ROAD AND BRIDGE STANDARDS STANDARD BLOCKED -OUT W-BEAM GUARDRAIL REFEREJCE 41EFr 1 or 2 REVISION DATE (STRONG POST SYSTEM) Do's 5p104 ON/M VIRGINIA DEPARTMENT OF TRANSPORTATION VDOT: GR-2 NOT TO SCALE SHIMP ENGINEERING LAND PLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM p,LTH �O HIMP lic. 45183 I od"IIIIII K' SIONAL FINAL SITE DEVELOPMENT PLAN 999 RIO ROAD ALBEMARLE COUNTY, VIRGINIA SUBMISSION: 2020.05.26 [INITIAL SDP] REVISION: 2021.01.21 [FINAL SDP] 2021.02.22 [ARB] 2021.04.13 [ACSA] 2021.05.10 [ARB] 9111110111►161 SITE, VDOT & ACSA DETAILS Mai 3 VDOT: STD. DROP INLET (DI-IA)C9_ C9 NOT TO SCALE 5 V COMPRESSION X 3/4' OR APPROVED EQUAL O FOR USE ON ATTACHE SINGLE FAMILY AL SERVICES OR DUAL RESDENTAL R RND RRI SERVICES. AND IflSGATON YRNCFS. 4R�NM TEENO NO 2. DUAL SERVICE L I' COMPRESSION . 3/4" MALE PIPE COUPUNC M APPROVED EQUAL 1' TYPE 'M SOFT COPPER O DR UALAI DETACHED SINGLE FAMILY RESIDENTIAL WHERE AN IRRIGATION METER IS NOTT PROA FRONDED. SINGLE SERVICE NOTE 1) SADDLES SHALL BE USED ON PVC PIPE. CAST IRON UD FINISHED MADE 12•-15 LOCKMNG METER yA�LL eox (INLET 6: QUIET) 36' MIN. COPPERSETTER 1/6 BEND COUPLING 9s METER CORPUUTON STOP ^/5'Y:"s'• _ BRICK AS NECESSARY SANG A DUST UNDER `�/''f':/..-"_,. ;'• �C.�Ef';;G 4' DIAMETER DRAWN PIPE, 12' BOX AND BETTER (2-INCH ii�yi'See�.^.., , f .`. i"+T: LONG STO ME POCKET, WOT SEC. 203. NO. 57 AGGREGATE MINIMUM THICKNESS) sy?. ;AA,�L,•.K,Vy'•},-!_L .-1M.;,�;J TYPICAL SERVICE LATERAL INSTALLATION (5/8" & 1" METERS) NTS FIG. W-6A TD-10 1�)ACSA:5/8" & 1" WATER METER INSTALLATION C1 NOT TO SCALE CG-12 NOTECOMPONENTS OF CURB RAMPS CONSIST OF THE FOLLOWING' HYDRAULIC CEMENT SIDEWALK (DEPTH IH INCHES. AREA N SQUARE YARDS) CAR WHEN EWNED ICC-2 ON CC-3 IN LFEAR FEETI GENERAL NOTES: DETECTIBLE WARNING SURFACE IMEA N SQUARE YAAUSI 1. THE DETECTABLE WARNING SHKL BE PROVIDED BY TRUNCATED DOLES. EACH I THE MOVE ITEMS IS A SEPARATE PAY ITEM AND SHOULD BE SUMMARIZED FOR EACH CAR CUT RAF. 2. ALL DETECTMLE WARNING SURFACE PRODUCES SNVL AIEEI MF EOUIREMfNTS t4811 tM" OF SECTIOE 504 OF `HE SPECPNDOUCOTS FORUSECGH12 ETTEFROM CTABLTHE MATE IAB`ACE, PROVEOPR ARNIN LIST ACE PR T23. SLOPING WES OF CURB RNF MAY K POUED MONOLITHICALLY WITH RAPFLOOR ON BY US'NG PERMISSIBLE CONSTRUCTION JONT WITH REWIRED BARS. 44. SEWNED BASS ARE r0 BE K0 5 X B" PA:ED 1'CENTER TO CENTER ALONGWIN SEES OF THE RAMP FLOW. MIDDEPTH OF RA,p FLOOR. MMNAM CONCRETE COVER 4/i'. uM 5. ROADWY CUM / CURBRAIMPSAARE INCLUDED IN PPAAY)MENTTFORGUTERS CURB / CURBANSIT( µ ADJITERR TO CURB TYPE A 6. CURB RAMPS ARE RECURRED FOR SIDEWALKS AND SHARED USE PATHS THE WIDTH OF PERPENDICULAR J✓� COWUNCTJ N RAMP SHAREMATCH USE EPATX THETMMMMH. N MOTH R$HAFLL BE THE ARE USED y. WAY Kr K,'4:I �IY�KHSR',C Ni •Q,P fyyTY„55M1 OF THE SHARED USE PATH - v1"Re•1. 1 :j'yA%L.•ASii�NYi j1fIY,'" N•I VmN ]. DETECTLF GFLOOR SHULL EXTEIO ME FULL WIDTH OF THE CURB PIMP Lmomc e. OUR RAMPS WILL BE INSTALLED AND LOCATED WITHIN PEDESTRIAN CROSSWALKS 12MIN AS SHOWN ON FILMS OR AS DIRECTED BY THE ENCNEER. CAN RAMPS SHOULD N07 B ETC. PE BEHIND VEHICLE LINES: E STEP LIGHT POLES. FIRE HYDRMIS.DROP BTYPE B 9. THE CUFBYOSE KNNc Is PLLAACERD WIITT" THE Ellis Of THE CROSSSWALLKKDAND PARALLEL THAT THE SLOE AT THE CONNECTION OF THE CURB OPENING S PERPExDCOAR 10 THE CURB. _ 10. Cf TIDE (MILE WARNING SURFACE PANELS SHALL BE INSTALLED FLUSH MTN THE BACK OF CURB. _ -- II. WHERE CURB MAKERS INTERSECT A RADIAL SECTION OF CURB AT ENTRANCES A tACYORY RADIUS STREET CA BETIONS Tf4LD MODIFIEDEAS RECOMMENDED BY INS WARNING SURFACE SHALL HAW 5 4N )K* YAAFACTWER TO MATCH THE STICK OF CEASE SEE CC-12-INS PAGES 204,06 AND 204.07 FON METHODS OF NSTALLNG DETECTABLE WARNINGS ON A RADIUS- •'. <. X .2' IUGHEN THAN EDGE OF PAVEMENT Ar %% ,SAME AS i0P a CUS TYPE C PARALLEL & PERPENDICULAR TRUNCATED DOME y1 .6"-2.4" C-C d O O O O O W - 0 0 0 0 0 O Q Q 0 0 0 O _ mr Q D D D D Q Q D D D D D LNIdXE RNP y1 000000000000000 y N 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Q D 0 0 0 0 0 0 0 O O O O O Q 0 0 0 D 0 0 0 0 0 O 0 O O O D 01'65'M DI BASE OIAMEifR AMETER O O O 0 0 O 0 O 0 O 0 0 0 0 O 'OEAT BAN LE WARNING SSEENO ILE CURB c O.9 Ad VARIABLE FULL WIDTH OF RAW FLOOR r PAY LMls DETECTABLE WARNING TRUNCATED DOME DETECTABLE WARNING INSTALLED ON A RADIUS DETAIL DETAIL `VDQ-F A COPv OF tK ORmIt AI 5E 4M AO SIGNED DRAWING I ON FILE N THE CENTRAL OFFICE. SPECIFICATION READ ND BRIDGESTANDAROS CG-12 DETECTABLE WARNING SURFACE KFERENDE sHECT I OF 5 REVISON OME (GENERAL NOTES) w5 042M F V+:IA DEPARTMENT OF TRANSPCBLTION 504 2D4D, VDOT: CG-12 GENERAL NOTES NUI IU SCALE CG 12 °5 DOWELS, 8" LONG lT PERMISSIBLE R AT 12" C-C 5'ILWR, JOIMiTRUGTION OIN IN i2-I MAX N' MN 12:1 MAX Y 1 P\ RM1P RNF JT WITH BUFFER STRIP MYf iMLEI (SEE rMLEI }RMSITOI WrtER P4Y SLOPE TRANS, WiiER PM SLOPE 10 20:1 TNROUGH RAMP LENGTH 2_I 5'Iury TO 20.1 TMWGH RAP LENGTH GUi I[R PM 4MWW SLOPE 20'I 77!Z v-o MIx SHAPE TD'Y CWB MATCH FACE WITHOUT BUFFER STRIP "' Pt U BACK OF too, LN"B 4 ., EXAMPLE INSTALLATION METHODS - SEE PLANS FOR LAYOUT SI .MI MA` 2"' MIN. SECTION A -A mi",6, MA<, R.aE DEtEC1ABLE WMNNG SIEACE PERMI_,I CVRB y c.NSrRKnoN ByH INN CROSSWALK �MuMy, r SECTION B-B R'"c1R`'S Cow " COME NOTES: ONE DIRECTION ONE DIRECTION 1. FOR GENERAL NOTES ON THE DETECTABLE WARNING SArADE. SEE SHEET 11 5WITHOUT BUFFER STRIP WITH BUFFER STRIP 0. _ t THE RECOMEO LENGTH OF A PARALLEL RAMP IS LIMITED TO 15 FEET, REGARDLESS OF THE SLOPE. 3. UTTER PAN SNAIL BE A MAXIMUM SLOPE OF 20.1 AT THE RAMP OPENING, 4- OACONAL PLACEMENT 5 NOT PERMITTED. TYPE 8 PARALLEL APPLICATION ROINWAY GRACE N REKENT MINIMUM RAN LENGTH N FEET ." CWB V CURB D 6 1 5 2 5 e 3 e 9 : s 10 0 6 14 IS CROBSWAN CROSS T 1 pp CROSSWALK TWO DIRECTIONS SMALLER RADII WITHOUT BUFFER STRIP `VEND-F A COPY Of THE ORIGWAL SEALED AND SIGNED OPENING IS ON FEE IN THIS CENTRAL OFFICE- SEC6MCA11W ROAD AD BRIDGE STANDMlOS CG-12 DETECTABLE WARNING SURFACE E""E"" SHEET 3 OF 5 REVISION DATE TYPE 8 (PARALLEL) APPLICATION 105 502 IOlO] 0.119 VIRGINIA DEPARTMENT OF TRANSPORTATION 504 3 VDOT: CG-12 TYPE B C10 NOT TO SCALE TACK COAT THE PROPOSED CONSTRUCTION JOINT EXISTING ASPHALT LAYERS PROPOSED ASPHALT LAYERS EXISTING SESSIONS PROPOSED SUBBASE COMPACTED SUBGRADE CONSTRUCTION JOINT DETAIL ® REMOVE EXISTMT ASPHALT LAYERS TO EXISTING SUBBASE AND REPLACE NTH PROPOSED ASPHALT WIDENING LAYERS ® PROPOSED MINIMUM 11/ INN THICK ASPHALT SURFACE COURSE fSEE NOTE 5) " MfRRIJM 12 ACHES. A GREATER AS NECESSARY TO ABUT THE FULL THICKNESS OF EXISTING ASPHALT LAYERS A4 I]ETERMNED BY CORES ISM NOTE 3) NOTES; E ASPHALT PAVEMENT WDERNG SHALL HAVE A PAVEMENT DESIGN IN ICCOlDAICE WITH CURRENT VOOT PROCEDLPES AND BE APPROVED BY THE ENSNEER. 2. THE PAVEMENT DESIGN FOR ASPHALT PAVEMENT WIDENING SHALL MEET A EXCEED THE DEPTHS AND TYPES OF THE LAYERS OF EXISTING PAVEMENT. SASRFACE MANAGE OF THE EgSTNG MD PDPOSD PAVEMENT SHALL BE AVMESSED IN THE PAVEMENT DESIGN. I A MNMJM OF THREE COTES SHALL E TAKEN ALONG THE CENTER OF THE ADJACENT TRAVEL LANE TO DETERME THE TYPE AND THICKNESS W EXISTING PAVEMENT LAYERS. THEY CONES SHALL BE SPADED NO MORE THAN 500 MET MART. 4. THE ADJACENT TRAVEL LANE SHALL BE MILLED A 1fNIM DEPTH OF 10 INCHES AND D O TBPLACNTH AN ASPHALT SURFACE COURSE TO MATCH THE PROPOSED PAVEMENT WIDENING SURFACE OWRSE,ULESS WAVED BY iE ENGINEER, 5. THE ENGINEER MAY REQUIRE THE MILLING DEPTH OF THE EXISTING PAVEMENT TO BE ADJUSTED TO ACHIEVE AN ACCEPTABLE PAVEMENT CROSS -SLOE AND EFFECTIVE SURFACE DRAINAGE. 6. EXITING PAVEMENT MARKINGS AND MARIFRS MEN THE PROJECT LIMITS SHALL BE RESTORED SUBMECT TO THE APPROVAL OF THE ENGINEER. 7. FAIL TRANSVERSE PAVEMENT TIE-IN SHALL CONFORM TO THE REQUIREMENTS OF SECTION 3161 OF THE SPECIFICATIONS EXCEPT THAT ALL JDNTS AT TE-M LOOATKNS SHALL Y TOFTD MISER A D FOOT STRAIGHTEDGE N ACCORDANCE NTH THE REQUIREMENTS OF SECTION 315A710 OF THE SPECIFICATIONS. RGAD ADS srAawmB ASPHALT PAVEMENT WIDENING -R�EffN - aEET 1 OF I REVN01H DATE FOR WIDENING SUBJECT TO TRAFFIC 50302 MINA DEPARTMENT OF TRANSPORTATION VDOT: ASPHALT PAVEMENT WIDENING NU I SCALE A GOMEL. 9- LONG a R^ C-C B LL "It i EI I I I B �TRWIHMP" GUTTER PAJ SLOPE TO 200 THROUGH RAMP LENGTH A iR SITION GUTTER PM! SLOPE GUTTER PN! YAXINLM COPE 201 TO 20A THROUGH RAMP LENGTH Irmo'Will, 1'_0" Xn 9. BACK OF 0.RB] r12'1 MAX- 4 20 I I 1 '4N_ SECTION A -A PEIFWSSIBLE CONSTRUCTOR JDNT SECTION B-B NOTES: t FOR GENERA NOTES ON THE DETECTABLE WMNNG SURFOCE,SEE SHEET ICE S. 2, TMIS DESIGN TO BE USED FOR CONSTRUCTION THAT INCORPORATES WRIER 50EWALK LANDING U'MOE)REQUIRED AT TOP OF [(NI RAF, MINIMUM CL.PI RAID LENGTH B FEET FOR NEW CONSTRUCTION. 3. GUTTER PAN SHALL Y A MANIMW SLOPE OF 200 AT THE RAMP OPEMNG. a. DIAGONAL PLACEMENT IS NOT PERMITTED. EXAMPLE INSTALLATION METHODS - SEE PLANS FOR LAYOUT Y Y � K U TYPICAL PLACEMENT AT INTERSECTION WITHIN CROSSWALK l.I.P IL Ut I L1_ I AULL YYAK NIINIo JUh 105 TYPE A (PERPENDICULAR) APPLICATION 502 s04 NRGIMA DEPARTMENT OF TRANSPORTATION `5�VDOT: CG-12 TYPE A C1 O /NOT TO SCALE CC 12 INS EXAMPLE BLENDED TRANSITION (NOT FOR USE IN NEW CONSTRUCTION FOR RETROFIT OR ALTERATIONS ONLYI 2'. SDETECTMLE WARNING PANEL -2', 3'DETECTABLE 2'. 4-DETECTIBLE wMVNC PANEL WARNING PANEL i I �\_'FAGIORY EDGE IG LAS"LU LINT FACTORY EDGE EXAMPLE CUI \11 PATTERN VLWA WARNING PANEL WARNING PANEL DETECTABLE M 4X4 4X4 POST POST )DOG PARK FENCE DETAIL C1 NOT TO SCALE Q TOP RAIL PALLET QUANTITY = 80 2' X 6" X 94-1/2• Deco Rai Ribbed. Qs PICKETS 0 PALLET QUANTITY - 12 Fill Kits 7/8' X 7' X 39-1/4". 12 Me v z' Full pickets and one end picket With tongue removed. 0 PICKET END CHANNEL Ba• 7/8" X 1' Qi BOTTOM RAIL Qi C' PALLET QUANTITY = 80 -. 2' X 6" X 94-1/2' Deco Rai Ribbed. Includes steel channel. © POST PALLET QUANTITY : 48 5'X5'X84' POST CENTERS -5X5=961/8• SCAN TYPICAL PLACEMENT AT INTERSECTION 8 WOODEN MECH. EQUIPMENT FENCE DETAIL WITHIN CROSSWALK (WITH BUFFER STRIP) NVDOT C1 O NOT TO SCALE NOTE: TO BE PAINTED WHITE OR TO MATCH THE ADJ. RESIDENTIAL UNIT ROAD AND BRIDGE STMOARDS REVISION DATE SHEET 2 OF 5 0./,9 xOADa EXAMPLE RADIAL INSTALLATION FACTORY EDGE TO FACTORY EDGE WMNNG PANEL TYP. DASHED LINE mmi, ::EXAFL•i •:•III^PATTERN •• i ..��.: NOTES L LOCATIONS WHERE THE DETDTA$E WARNING CANNOT K (INSTALLED WITH A MAXIMUM 2 OFFSET FROM THE BACK CP CURB SHALE HAVE A RADIUS 10 MATCH RADIUS OF THE CURB. DETECTABLE WARNING PANELS SMALL HAVE A FACTORY RAOUS OR IF MPROVED BY THE ENGINEER MAY BE FIELD MODIFIED AS RECOMMENDED BY THE MANUFACTWER TO MATCH THE BACK OF CURB. 2. JONTS BETWEEN DETECTABLE WMNNG PANELS SHALL BE FACTORY EDGES. CUT WES OF PANELS ME NOT PERMITTED TO ABUT ADJACENT PANELS. 3. AWNENT OF MKS. ON ADJACENT PANELS THAT WILL K MODIFIED TO FIT A RADIUS SHELL BE NA1iMME0 WHEN FIELD1A'JOFTNG DETECTAKE WHO PANELS. ! DETECTMLE WARNING PANEL SIZES SHOWN ME FOR EXAMPLE PURPOSES. OTHER PANEL SIZES MAY BE USED IN WKR TO MAINTAIN CONSISTENT ALIGNMENT OF THE DOMES FOR EACH CAR RAMP LOCATION. 5. BLENDED TRANSITION CURB MM'S ME FOR ALTERATION STUAVONS WHERE SI MEMO DIRECTIONAL CURB RAMPS ME HOT FEASIBLE WE TO STE CONStRM.ITS. BLENDED TRANSITgN CAS RAMPS ME NOT PERMTTED FOR NEW CONSTRUCTION 6. PARTIAL DETECTABLE WASHING DOMES THAT ME THE RESIAT OF CUTTING PANELS SHOULD BE CRWNO FLUSH ACTH THE PANEL SURFACE. 7- GARS BETWEEN ADJACENT DETECTMEE WARNING PANELS ME NOT PERMITTED. 6. SEE PANS FOR CROSSWALK MARKINGS. TURNING AREAS. ROUTE WEITHS. GRAM CHANGES, AND RAMP CONFIGURATIONS V, I A COPY OF THE ONIGNAL SEAR AND SIGNED DRAWING IS ON FILE N THE CENTRAL OFFICE, SPECFICATIVI CC-12 DETECTABLE WARNING SURFACE KFKOI IENCE ROM AND BRIDGE srAHIlMos sHEn 2 DF z REVISION DATE METHOD OF INSTALLING DETECTABLE WARNINGS ON A RADIUS wi 2a.07 MW 0.119 VRGNMAA DEPARTMENT- OF TRANSPORTATION- SOL ::6:)VDOT: CG-12 METHOD OF INSTALLATION C1 NOT TO SCALE 6" - 3,000 PSI CONCRETE AT 28 DAYS OR STRONGER. WIRE REINFORCING OR 00ooD000o00000000 #4 BARS AT 12" O.C. 4 COMPACTED VDOT #21A COMPACTED SUBGRADE TO BE FIELD VERIFIED 10 TYPICAL DUMPSTER PAD SECTION ;1 O NOT TO SCALE X 6" BOLLARD X 4" WOODEN POST . d N D d. . o D FENCE BOARD 1A_D 2" X 4" RAIL (TYP) , D D A D D , 4" X 4" STEEL COLUMNS FOR GATES A 9.. D , ., .. .,- . * :P• 4" X 6" TREATED WOODEN GATE FINISH TO MATCH BUILDINGS °< D: D , I• A' A ,..D C: CONCRETE PAD A s J 6, . X, 20'': AA.., p A. A 11 )DUMP 'TER PAD DETAIL C1 O NOT TO SCALE WOODEN NCE BOARD 4' STEEL COLUMNS FOR GATES X 6' 6" TREATED WOODEN FINISH TO MATCH BUILDINGS 4" RAIL (TYP) DRETE PAD HIRE JIESH FO BE NSTALLED 3EHIND NOODEN 3ILATS 01 12' POST 9 \WOODEN SCREENING FENCE DETAIL POST NU I SCALE 4" - 3,000 PSI CONCRETE 4" - VDOT #21A BASESTONE COMPACTED SUBGRADE MIN. CBR=6.0 TO BE FIELD VERIFIED 12 TYPICAL SIDEWALK SECTION ;1 O)NOT TO SCALE 1.5" OF SM-9.5A 2" OF BM-25 0000000000000000 6" - VDOT #21A BASESTONE m COMPACTED SUBGRADE 13�TYPICAL PAVEMENT SECTION C1 O NOT TO SCALE .375 5 c 2 2C 1 2C 1 6 R RIES& I MYA�ME 15 . A � Z5 © 2 R7AD R7.8 NO PARKING M �E A 1B C G 1 E r G N J X L LEGEND - GREEN (RETROREFL), WHITE SYMBOL ON BLUE(RETROREFL) 'z a 316 4D 1s 15D B 1D IBM in 11 BACKGROUND- WHITE(RETROREFL) 0 Ie a M 4Y 225 2G I USG I ISO I STBI IB "Reduce spacing 50%. PMINGA2n 7m GKGIBMLI2Prw **Seepage6-31. COLORS. LIED -GREEN IGETROIERfLRE!ITIXACIR UAGRR LEGEND -wxGE !RfTNOR1IECINfU • • •See page 6-2 tar arrow design. 6"2!ARBND-wllrt IRFiRNHIECIM) IYOIGRCIID-Nu IELRDEREcrNn 14 HC PARKING SIGNAGE C1 O NOT TO SCALE 4825' RESERVE425 5' D PARKING 4" ' 383 3825 .75 W T L SHIMP ENGINEERING LAND PLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM or O ANC Si U Ris�x11P a 45 lic. 183 K' SIONAL FINAL SITE DEVELOPMENT PLAN 999 RIO ROAD ALBEMARLE COUNTY, VIRGINIA SUBMISSION: 2020.05.26 [INITIAL SDP] REVISION: 2021.01.21 [FINAL SDP] 2021.02.22 [ARB] 2021.04.13 [ACSA] 2021.05.10 [ARB] 19.006 SITE, VDOT & ACSA DETAILS C10 FRAME & COVER '• COMPRESSION . 3/4' MALE PIPE COU°UNG OR APPROV0 MUAL (SEE FIG. S-I-D,E) SEWER SERVICE LATERAL CONNECTION NOTES: OD 1. WHERE A SEWER SERVICE LATERAL CONNECTS TO A MANHOLE STREET SURFACE OR i' TYPE x' AND NO INVERT ELEVATION FOR THE SERVICE LATERAL IS w NON -PAVED AREA SOFT COPPER FOR USE ON ATTACHED SINGLE FAMILY INDICATED THE TOP (CROWN) ELEVATION OF THE SERVICE _J Z SLOPED AREA RESICENBAL sD3 ICES OR DUAL FEWOEN11AL AND IRRIGATION SERVICES , LATERAL PIPE SHALL BE AT LEAST 0.2' HIGHER THAN THE TOP (CROWN) ELEVATION OF THE THE LOWEST PIPE CONNECTED ... TO THE MANHOLE. 1'-0" MAX " 2. SEWER LATERALS TAPPED INTO AN EXISTING SEWER MAIN SHALL 3000 PSI CONC. BASE 2 -0 NOTE BE CONNECTED USING A PIPE SADDLE. BENCH SLOPED TO FLOW SWEATS. nmNGS �� 2. 3. MINIMUM GRADE FOR SEWER SERVICE CONNECTION SHALL BE 2% Q (1/4" PER FOOT) �1 _ CHANNEL 1 /4" 1' MIN RUBBER COATED STEEL 3 MIN DUAL SERVICE R I.o ;' Q ■ STEPS CAST IN PLACE -0 1' cdJPREsyan . �/+' MALT 'RE CwnuNc 4. ALL SEWER LATERALS SHALL HAVE A MINIMUM COVER 2' MIN PRECAST REINFORCED OR APPROVED EWAL DIAMETER OF 4". CONCRETE SECTIONS 12"" MIN P0" RING SEALS 16" MAX TYPEx' SOFT COPPER 5 OF SEWER ET. LATERALS SHALL HAVE A MINIMUM COVER 77 t - BRANCH MINIMUM ELEVATION t 12 � 1 1 ■ DIFFERENCE ACROSS M.H. 5" 4'-0° 5' � FLI+ USE ON DET.CHr, eN(xs FAMILY SALT FROM INLET TO OUTLET � WIER 15 N SERVICE FWERE AN IRRIGATION TREATED N., SHALL BE 0.20 FEET. _ 2 x 4 FINISHED GROUND -� CONCRETE VARIES MARKER o 2 DEPTH OF FLOW FILLETS srucLE SERVICE CHANNEL TO BE 3/4 DIAMETER OF 1) SADDLES SHALL BE La' DN PvG PIPE CONTRIBUTING -- '=-sr_- q CAST IRON UP. SEWER. a a. ° s q A 12 FINISHED GRADE A FILLETED INVERT FOR A SMOOTH d r '2'-•s- NOTE: TRANSITION OF FLOW BETWEEN FLEXIBLE CONNECTION INLET &OUTLET PIPE SHALL BE LSIGKAING n °AL%E '+ h -BO R WITH STAINLESS STEEL ALL CONNECTIONS TO PROVIDED. MIN. 6" BEDDING I LI LEi;pl r BAND EXISTING MANHOLES SHALL NOTE W/ N0. 68 STONE 3D MIN a,P {x9ET1EA w BE CORED AND A FLEXIBLE PLUG END OF CONNECTION " BOOT " 1. BEDDING THICKNESS REQUIREMENT SHOWN IS MINIMUM AND SHALL BE a DENC COUPLING as ' MAIN LINE SERVICE LATERAL oINSTALLED SPECIFICALLY DETERMINED BY THE CONSULTANT FOR THE SOIL CONDITIONS. E� SECTION 2. THE CONSULTANT WILL DETERMINE WHETHER MANHOLES SHALL HAVE �NErE= ,:;:.::. s.:' 45'00 EXTENDED OR NON -EXTENDED BASES.'r' ai`-o .law "/i`".i4 3. ALL JOINTS, LIFT HOLES, INLETS, OUTLETS TO BE SEALED & GROUTED;.. v: ICK A'S ORPORATION 5RIP 1'!yy'•;.7 'elV��--rd!I� NNEECESSARY TYPICAL MANHOLE PLAN INSIDE AND OUT. ='=i5"°' � .1 ' SAND OR OUST ,HIDER ;: 4' OIAVVIER OR044 PPE 12' BOX AND SErIEt (2-INCM 4 1I;'.-K y','!i+'�*}f LONG STOW POCKET. VDOT SHOWING BRANCH TIE - IN TYPICAL MANHOLE SECTION MINIMUMTMCkNE55,:°:;,.�-=, _:=:=>?fixW.C. 2O&nO 57A 3ELgE SHOWING BRANCH TIE-IN TYPICAL SERVICE LATERAL INSTALLATION NTS N.T.S (5/8" & 1 METERS) IN LINE WYE-TEE FIG. S-I-B FIG. S-I-A PLAN NTS FIG. W-6A VARIES TD-27 TD-25 TD- t 0 R 1 ACSA: TYPICAL MH TIE IN PLAN VIEW 3 ACSA: TYP. MANHOLE SECTION BRANCH TIE-IN 5 ACSA: TYP. SERVICE LATERAL INSTALLATION SEWER SERVICE LATERAL CONNECTION C11 NOT TO SCALE C11 NOT TO SCALE C11 NOT TO SCALE N.T.S. FIG. S-2 SHIMP TD-33 L- E GALVANIZED " WITNESS " POST WITH GOOD FOUNDATION MATERIAL ROCKY FOUNDATION MATERIAL -- EETED, '^-L' ER LOCA11ON MAYBLUE IN REMOTE E SUBJECT 7 ACSA: SEWER LATERAL CONNECTION ENGINEERING T HI H "? Y" l E=RTMENT APPROVAL. NOTE; MIN. 60' DIAMETER MANHOLE REQUIRED. LAND PLANNING -PROJECT MANAGEMENT C11 NOT TO SCALE [� q FI I HE -cA-E M.H. STEP (TYP.) q DROP MANHOLE PVC CROSS U� q r� 24" IN 24' N INITIAL BACKFILL g" g" g" g" 912 E. HIGH ST. 434.227.5140 --- USE APPROVED FLEXIBLE RUBBER �i(' q 2' Boor. MIN MIN. MIN. MIN. O ` CHARLOTTESVILLE VA 22902 JUSTIN@SHIMP-ENGINEERING.COM r• o° r :; ,.xF,. 6" BEDDING it f e o > ,fs : x'. #68 STONE L1 AD TµDLE TTED RAFFIC RATED " a STOPGASKELOUPLING *STABLE SOIL ROCK VALVE $DX W/ LID o - z7• *SCRAPE THE BOTTOM OF THE TRENCH. REMOVE ALL I TH A A O Li � DROP PIPE STONES TO INSURE THE PIPE DOESN'T REST ON ROCK AND PIPE STRAPS e ° (STAINLESS STEEL) (STAINLESS SPACED EVERY THEN COMPACT THE SOIL OR PROVIDE A 4" BEDDING OF #68 STONE. NOTE: HYDRANT MUST BE EQUIPPED WITH CHARLOTTES - VILLE THREADS WHICH IS QS� 2' VERTICALLY a q 90' RESTRAINED BEND THE LOCAL STANDARD. � U JJS' �HIMP > T�1R345 SEWER FOUNDATION IN POOR SOIL UNDER -CUT CONDITION LENGTH OF BRANCH VARIES A : PIPE INFLUENT 6' MIN 2' TO 10' Ap (270) ��SSIONAL �. R SEWER 18"-22" V, ic A 4 AA44 7 CU. FT. VALVE BOX M .). GATE VALVE PLAN 4' 11 INITIAL BACKFILL 4 MI #68 STONE UNSTABLE a" e" B" s" --- --" SOIL- MIN O MIN.MIN MIN. #68 STONE ----- MIN, 6' BEDDING WITH NO, 68 STONE =GRANULAR FILL AS :, i' ` _APPROVED BY ACSA ` ` �;, 6" GATE 42"MIN . ° o o', VALVE 1. HEIGHTOF THEVERTICALDROP PIPE WILL BE DETERMINEDBYTHE ACSA, BUTSHALL NOT BE LESSTHAN TWO .a STABLE A '^III; 8" X 6" FINAL SITE DEVELOPMENT PLAN SOIL OR ROCI STABLE SOIL OR ROC (2)FEET. TEE T WA TE II LL`iE 2. VERTICAL DROP PIPE SHALL BE SDR 26 P.V.C, SIZED THE SAME AS THE INCOMING PIPE AND CONNECTED TO 2500 P.S.I. CONCRETE .' . °. •. ;�: :�r: 999 RI O ROAD / Ir THE DROP FITTING WITH STANDARD GASKETJOINT. NOTE BASE AND THRUST j • d 3.VERTICALDROP PIPESHALL BESTRAPPEDTOTHE MANHOLEAT PIPEJOINTS. STRAPSSHALL BEMADE OF 1. NO ROCKS SHALL BE ALLOWED WITHIN 24" OF THE WATER LINES. BLOCK AGAINST UNDISTURBED STABLE 1 _ 1 STAINLESS STEEL. 2. NO ROCKS LARGER THAN 6" IN ANY DIMENSION SHALL BE ALLOWED SOIL. STEEL PILE 4. SHAPE INVERT AS NEEDED TO PROVIDE SMOOTH TRANSITION FROM DROP CONNECTION DISCHARGE POINT ABOVE THE INITIAL BACKFILL. RESTRAINED JOINT FITTINGS 2500 P.S.I. TO SPRING LINE OF MANHOLE INVERT. 3.THE INITIAL BACKFILL SHALL BE PLACED AND COMPACTED IN 6" LIFTS. WHEN THE SOIL IS DISTURBED OR WHEN CONCRETE '.<F a 2'x 2' BEARING A, E- 4. NO ORGANIC OR FROZEN MATERIAL OR DEBRIS SHALL BE ALLOWED A HYDRANT IS LOCATED IN A FILL, IN ADDITION ALBEMARLE COUNTY VIRGINIA THRUST BLOCK 5. DROP CONNECTION DISCHARGE FITTING SHALL BE ORIENTED AT 45 DEGREES, INTO THE FLOW. TO POURING CONCRETE, A STEEL PILE SHALL IN THE TRENCH. BE USED AS ADDITIONAL SUPPORT. SUBMISSION: 6. VERTICAL DROP PIPE SHALL BE INSTALLED AT 90 DEGREES FROM THE ACCESS STEPS. 5. BELL HOLES SHALL BE DUG OUT IN ALL CASES. 7. MINIMUM 72" DIAMETER MANHOLE REQUIRED FOR ASINGLE 10" OR 12" DIAMETER DROP CONNECTION, OR 2020.05.26 [INITIAL SDP] - R TWO 8" DIAMETER DROP CONNECTIONS. a DUCTILE IRON WATER NOTE : REVISION: STANDARD INTERNAL DROP CONNECTION 2021.01.21 [FINAL SDP] PIPE INSTALLATION & BEDDING 1. SURROUND WEEP HOLES WITH GRAVEL AND KEEP FREE OF CONCRETE. N.T.S. 2. MAINTAIN A 3 1/2' MIN. COVER FROM THE MAIN TO THE FIRE HYDRANT 2021.02.22 [ARB] NOTE IN REMOTE AREAS, VALVE BOXES SHALL EXTEND SIX (6) INCHES ABOVE GRADE FIG. S-1-122 3.(FINISH DINDITCHES GRA ESHALL SLOPE AWAY FROM THE ERE HYDRANT AND 2021.04.13[ACSA] FIG.TW-2 VALVE BOX. 4. THE GATE VALVE IS ALLOWED IN SHOULDER OR BEHIND THE DITCH. 2021.05.10 AR [ B] TD-30 TD-2 TYPICAL GATE VALVE IS NOT THE DITCH. 4 ACSA: INTERNAL DROP CONNECTION 6 ACSA: DIP INSTALLATION 5.IFIRE HYD ANT SWSDHAILL BE INSTALLED AT LOCATIONS WHERE WEEP HOLES ARE ABOVE THE PREVAILING GROUNDWATER ELEVATION. IF NTS REQUIRED TO BE IN WET AREASTHE WEEP HOLES SHALL BE , C11 NOT TO SCALE C11 NOT TO SCALE FIG. W-5 PLUGGED AND THE HYDRANT SHALL BE PUMPED DRY. FILE NO. 19.006 TYPICAL FIRE HYDRANT ASSEMBLY DETAIL 2 ACSA: GATE VALVE TYP. N.T.S. ACSA DETAILS C11 NOT TO SCALE FIG. W-4 TD-8 8 ACSA: FIRE HYDRANT ASSEMBLY C11 NOT TO SCALE c 11 W III 6X6' LANDSCAPE EASEMENT PRIVATE STREET LAYOUT DETAIL NOT TO SCALE �_I GEOSYSTEMS Based on the evaluation, the following material is are recommended for the Geoweb application at the site. We assumed a heavier aide loading to account for construction traffic on the mad. 1. Prepare sub grade to a minimum CBR of 6.0%. 2. Provide a 4800 111 enhanced woven geotextile separation layer on top of Me sub grade and install in accordance with Manufacturer instructions including overlaps based on sub grade CBR. 3. Presto Geoweb GI IS - inch) panels filled with Engi nerd Fill. 4. Engineered infill shall to a mix atopsoil and aggregate having a homogeneous m0dure or a clear Crushetl aggregate having an AASHTO MS or similar designation blended with pulverized topsoil and a minimum 30% void space for air andlor water. The aggregate portion shall have a particle range from 0,375 to ID Inches (9.5 to 25 mm) with a Do of 0.5 inches (13 rum). The pulverized topsoil portion shall equal 25%ofthe total volume. The topsoil shall be banded With the aggregate to produce a homogeneous mixture. Once placed, the engineered fill shall be Compacted to a 95%Standard Proctor. 5. Conned the Geoweb sections with ATRAO Keys at each interleaf and end to end connection. S. Preshape the Geoweb panels before infill placement. 7. Limit the drop of infill into the Geoweb panels to prevent distortion. 8. Provid e 2 inch wear surface of engineered fill. For add itional Load Support Resources, click here' Load Support Design Engineering Resource Package If you have any questions or need any additional information, please call. Sincerely, SasJustice,, P E. Civil Design Engineer Presto Geosystems ela.aw.,... OJo 11-i.... e �,�io>Rierev imu � Vue>w.."i.n.,m. Nate.: TNN .wN.tlx. b eopY tad and b booed an the uw 1 Geri Geow,b mxuhxered b, Pn.tu Product. te. All ridyt. rvrN. An, uw t t Ie ewlae:,m to, any ce Al product o•.her 111 Nor Mmubc+md by ormw Produce Co. M strictly prahbllyd and M..o. tho..wm.een ..no 2. 0.N0, town RAS ID Hm lodl6d. 30 Np .Irdl. d.lw loWlnv dlw 235 pit gi. ple..gr. Iw it. trvn auo.m X Cea..A ii cod bx. w, A.. ,pdd,ra. w .sAi o of 2/3 ....r.d .00,.vme and 1/3 top.u;l nl.. ARr,. ;d.SW a 17 .Nh o 050 W 0.5' end pronto 301 wN .px..h.n wmpo.:rd. 4. Bow .MI be d• ter OR bwr.n .2% e+d 49 and 4' lor CAR .bme 49. 4. . rynh.d,'".. 4d00 Ib./R e,h.ar.ral ... deoteAle vro—o'— I." anal .—toll in o.caderce .dh w—Iti kwer rwol+nTddVMe h.Ndll .wlNpe bd.ed alp cob Ovid. OR ♦ lbr G vM pmA ball be wnneard .IN A1RA by, or cod, ntM.uf old end to cod wnnxtbr L Prodde A'IRA M.h>. to be,p pm0. open tar n91na .. rcoPirect. ♦ limn tM dlop or RMI to pr.w,r l= Jbl,llm. VLCEl sJAME \ OCCAU :Alit'[ FLLED WI ENGINEERED INFILL sm WTE 0 00000 0000 0000 0ovo 0000 00000 v000 e0o0v o0g0 vovo ovovo G000° oo°o o°o° o°o° °o°v o°o°0 0000 0-000 0020 0°0° 00.00 0t37f6X1 WE N01E 3 7 a ° 7" — 3,000 PSI CONCRETE a a 9 ed <a d oOOOOOOOo0 000000 6" — VDOT #21A BASESTONE 00000000000000000 IiI liI liI liI l MIN.OM PCBR ACTED 6.0 U BGR ADE TO BE FIELD VERIFIED HEAVY DUTY SIDEWALK SECTION 1 2)NOT TO SCALE PULL POTTING MIX AND ROOT MAT APART TO DIRECT THE OUTER ROOTS INTO THE ADJACENT SOIL. DO NOT LEAVE CIRCLING ROOTS NATIVE BACKFILL SOIL AMENDED WITH 15% DECOMPOSED ORGANIC COMPOST SOIL SURFACE ROUGHENED TO BIND NEW SOIL _ —III TREE PIT DEPTH EQUALS R L PREPARE SUBSOIL TO DEPTH. MEASURE BEFORE DIGGING WITH MOUND TO - - PREVENT SETTLING v - 2X RODTBALL DIAMETER DIM. III III III III 1. SEE PLANS FOR EXACT LAYOUT. SPACE PLANTS AS SPECIFIED IN PLAIT LIST OR AS SHOWN. IF SPACING NEEDS ADJUSTING CONTACT LANDSCAPE ARCHITECT. 2. PRIOR TO MULCHING, LIGHTLY TAMP SOIL AROUND THE ROOT BALL IN 6" LIFTS TO BRACE SHRUB. DO NOT OVER COMPACT. WHEN THE PLANTING HOLE HAS BEEN BACKFILLED, POUR WATER AROUND THE ROOT BALL TO SETTLE THE SOIL. SET TOP OF ROOT CROWN 2" ABOVE FINISHED GRADE 3" DOUBLE -SHREDDED HARDWOOD MULCH. WATERING BERM SHAPE SOIL SURFACE TO PROVIDE 3' DIA. WATERING RING FINISHED GRADE SET TRUNK PLUMB, SEE PLANS FOR EXACT LAYOUT AND SPACING ONE CENTRAL LEADER (NO CODOMINANT LEADERS UNLESS SPECIFIED) ARBOR TIES, OR EQUIV. 2"X2" SQ. OAK STAKES SET 180 DEGREES APART OUTSIDE ROOT PACKAGE TOP OF ROOT BALL SHALL BE 2" ABOVE FINISHED GRADE 4" LAYER OF WOOD CHIPS. NO MORE THAN 1" OF MULCH ON TOP OF ROOT BALL. ROUND -TOPPED SOIL BERM 4" HIGH X 8" WIDE ABOVE ROOT BALL SURFACE SHALL BE CONSTRUCTED AROUND THE ROOT BALL. BERM SHALL BEGIN AT ROOT BALL PERIPHERY. REMOVE BURLAP, STRING, AND WIRE FROM TOP 2/3 OF ROOT BALL. BOTTOM OF ROOT BALL RESTS ON EXISTING OR RECOMPACTED SOIL TO PREVENT SETTLING SLOPE AND ROUGHEN SIDES OF LOOSENED SOIL. SHRUB PLANTING — SECTION Not to Scale L E- 3X ROOTBALL DIAMETER DIM. TREE PLANTING DETAIL 12 Not To Scale VARIABLE WIDTH ROW o.o'1-1 10.0' 0' too' o.o' o' zo.o' BUILDING PLAYSCARE PAVED STREET PLAYSCARE UILDIN SETBACK AREA AREA ETBAC 2.0% z � f 2.0% - A �K� 7� 6" — GEOCELL W/ GROUNDCOVER MIX SEE DETAIL 2/C12 7,p,,OM�TED BROWN STONE TAR 6" — VDOT #21A rL & CHIP SURFACE BASESTONE SUBGRADE 8" — VDOT p21A (CBR = 6) BASESTONE SEE DETAIL 2/C12 PRIVATE STREET SECTION C1 2 NOT TO SCALE FINISHED GRADE EXISTING GRADE Y RIO ROAD EAST �; �l GRADED AREA MAINTENANCE F111111A� TRAVEL LANE BIKE LANE LANDSCAPE MULTI -USE PATH RIO ROAD EAST STREET SECTION NOT TO SCALE SHIMP ENGINEERING LAND PLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM OMV7��p,LTH o� 070 10 �I U JUSHIMP a I. D.O. AIRAw B5�TN.,DeR 7 KS810'NAL GUI E4 I — '�x E. G�m LOAD2-�p�.......... 1 Arm,'vAl ATM YEY 'i PRIVATE STREET REINFORCED TURF GEOCELL - MFR DETAILS NOT TO SCALE NOTE: Emergency access must be able to support 80,000 Ibs in all weather conditions. SEE TREE PLANTING DETAIL FOR STAKING ROOT BALL MODIFIED AS REQUIRED ROUND -TOPPED SOIL BERM 4" HIGH X 8" WIDE ABOVE ROOT BALL SURFACE SHALL BE CENTERED ON THE DOWNHILL SIDE OF THE ROOT BALL FOR 240. BERM SHALL BEGIN AT ROOT BALL PERIPHERY. 4" LAYER OF MULCH. NO MORE THAN 1" OF ON TOP OF ROOT ORIGINAL SLOPE SHOULD PASS FINAL SITE DEVELOPMENT PLAN THROUGH THE POINT WHERE THE TRUNK BASE MEETS SUBSTRATE/SOIL 999 RIO ROAD PRIOR TO MULCHING, LIGHTLY TAMP SOIL AROUND THE ROOT BALL IN 6" LIFTS TO BRACE TREE. DO NOT OVER COMPACT. WHEN THE PLANTING HOLE HAS BEEN BACKFILLED. POUR WATER AROUND THE ROOT BALL TO SETTLE THE SOIL. ALBEMARLE COUNTY, VIRGINIA SUBMISSION: LOOSENED SOIL. DIG AND TURN THE SOIIL TO REDUCE THE COMPACTION TO THE AREA AND 2020.05.26 [INITIAL SDP] DEPTH SHOWN. REVISION: SLOPE AND ROUGHEN SIDES OF 2021.01.21 [FINAL SDP] LOOSENED SOIL. 2021.02.22 [ARB] 2021.04.13 [ACSA] ORIGINAL GRADE 2021.05.10 [ARB] EXISTING SOIL IIIIIIIIAN01161 19.006 SITE DETAILS 3X WIDEST DIMENSION OF ROOT BALL -I 6 TREE ON SLOPE @ 25% 4: 1 to 50% 2: 1 C 12 C12 Not To Scale Page 611-14 September 2019 Typical Traffic Control Stationary Operation on a Shoulder (Figure TTC4 2) NOTES Standard 1. For long-term stationary work (more than 3 days) on divided highways having a median wider than 81, sign assemblies on both sides of the roadway shall be required as shown (ROAD WORK AHEAD (W20-1), RIGHT SHOULDER CLOSED AHEAD (W21-5bR), RIGHT SHOULDER CLOSED (W21-5aR)'), even though only one shoulder is being closed. For operations less than 3 days in duration, sign assemblies will only be required on the side where the shoulder is being closed. Guidance 2. Sign spacing should be 1300'-1500' for Limited Access highways. For all other roadways, the sign spacing should be 500'-800' where the posted speed limit is greater than 45 mph, and 350'400' where the posted speed limit is 45 mph or less. ODHOIC 3. 4. Standard: 5. Vehicle hazard warning signals shag not be used instead of the vehicle's high -intensity amber rotating, flashing, or' oscillating lights. Vehicle hazard warning signals can be used to supplement high -intensity amber rotating, flashing, or' oscillating, lights. 6. Taper length (L) shall be at the following: Taper Length L Speed Limit (Mph) no Width Fast Remarks L=S2w/GO L==SZ 60 L=S2W/5o L=S-W160 L=SW speedT Limit (Mph) ne Wimh Feet Remarks 9 10 11 12 9 10 11 12 25 95 105 115 125 50 450 500 550 600 L=SW 30 135 150 165 180 55 495 556 605 680 L= SW 35 185 205 225 245 60 540 1 600 660 1 720 L=SW 40 240 270 295 320 65 585 1 650 1 715 1 780 L=SW 45 405 450 495 540 70 630 1 700 1 770 1 940 L=SW Limited Access highways shall use a 10OW merging taper regardless of the posted speed, for shifting taper see Table 614.2' Shoulder Taper = Y3 L Minimum 7. Channelizina device soacine shall be at the following: Channeficing Device Spacing Spae:ng Speed Limit 'n h ion Spacing 0 Speed Lhaft m h Location Spacing Speed Limit (mph) 0-35 36+ 0-35 1 36+ 0-35 36+ Transition 1 20' 1 40- Travel 40' 1 80' I 'Construction Access 1 80' 1 120' "Construction access spacing may be increased to this distance, but shall not exceed one access per % mile. 8. On roadways with paved shoulders having a width of 8 feet or more, channelizing devices short be used to close the shoulder in advance of the merging taper to direct vehicular traffic to remain within the traveled way. 9. The buffer space length shall be as shown in Table 611-3 on Page 611-5 for the posted speed limit. 10. A truck -mounted attenuator (TMA) shall be used on the shadow vehicle on Limited Access highways and multi -lane roadways with posted speed limit equal to or greater than 45 mph for operations with a duration greater than 60 minutes. 11. When a side road intersects the highway within the temporary traffic control zone, additional traffic control devices shall be placed as needed. I: Revision 1-4/1/2015 2: Revision 2-9/1/2019 Page 611-48 September 2019 Lane Closure Operation with Temporary Traffic Barrier' (Figure TTC-20.2) NOTES Guidaance: 1. See Table 01-5, page 6H-6, for recom nded spacing of advance warning signs. 2. SHOULDER CLOSED (W21-5a) signs should be used on Lirrdud Access Highways where there ism opportunityfor disabled vehicles to pull off the roadway (see Figure TTC-6). 3. IO'hen closing a lane, a PCA& should be used in advance of the first warning sign if all of the left side 4. If drivers cannot see a pull -off area beyond the closed shoulder, information regarding the length of the shoulder closure should be provided infector miles, as appropriate. 5. An sonergencypull%'area shouldbeprovidedper Section 6G.18 and Temporary Traffic ConlrolFigure TTC-8. Standard: 6. On divided highways having a median wider than 81, right and left sign assemblies shall be required. 7. Group 2 chmnelWng device station shall be at the following: Group 2 Channellring Device Spacing Location Spacing Speed Limit (mph) O 35 36+ Location Spacing Speed Limk (mph) Location Spacing Speed Limit (mph) 0-35 36+ 035 36+ Transition 20' 40' TravelweIF 40' Ba Coretni on Accas8 80' 120' Construction access spacing may be increased m this dbtence but shall not exceed one access er'/. mile. Pa 9 Y P 8. For taper lengths, we TTC-19.1 9. See Table 611-6 for barrier transition flare rate.' When the barrier transition flare' Is on a horizontal alignment,the total offset shall be prorated around the curve in Neu of a straight-line P g flare. 10. End treatment of a barrier in order of preference: a. Where guardrail exists, attach to barrier with appropriate fixed object attachment. IN. Where cut slope exists, bury barrier into cut slope and provide for drainage as needed. c. Extend end of barrier until it is beyond the established clear zone (see Figure 2 on Page A-4 of Appendix A for clear zone values). PP ) Jr. When barrier end is inside the established clear zone attenuator service TypeI or Type e H shall be used. Refer to L&D special design drawings. 11. Barrier panels flinches in width and l2 inches in height shall be laced on to of the concrete barrier P g P P and spaced on 40' centers along the transition or taper sections and spaced on 80' centers along the parallel or tangent sections. Reflectorized surface shall be fluorescent orange prismatic lens P 8 g sheeting. The light at the beginning of the barrier run and at the breakpoint where the barrier becomes parallel to the roadway shall be a Type B flashing light. Barrier delinators shall be spaced on 20' centers along the transition or taper sections and spaced on 80' centers and centered' in- between the barrier panels along the parallel or tangent sections' approximately 24 inches up from the roadway surface. Guidance. 12. Eradication of existing pavement markings should be as shown in Figure TTC-55. 113. The barrier shown in this typical application is an example of one method that may be used to close a shoulder and lane' on a long-term project. 14. Long-term tmnsvere rumble strips maybe installed to enhance the work zone see Chapter 617, Section 6F- 99 pamgmph 12 and 13 for installation guidance and spacing. 1: Revision 1-4/112015 2: Revision 2-711/2019 September 2019 RIGHT SHOULDER CLOSED RIGHT SHOULDER AHEAD AHEAD ROAD WORK AHEAD l: Revision 1-411/2015 2: Revision 2 - 9/1/2019 Scplcmbcr 2019 Stationary Operation on a Shoulder (Figure TTC4 Maintenace of Traffic: Page 6H-15 TTC 20.2 & 23.2 to be used during entrance installation. TTC 4.2 to be used for multi -use path installation. G20-2 (V) 500' + 80' -120' - SHADOW VEHICLE REQUIRED >TMA REQUIREMENT SEE NOTE 10 ILLUMINATED FLASHING AMBER (CAUTION MODE) • SEE NOTE 9 TYPE B OR C • • • • SEE NOTE 6 • CHANNELIZING DEVICES SPACING SEE NOTE 7 NOTE 2 -5aR SEE NOTE 2 v reIGXi xoULDER LLDEfD W21-51DR AHEAD SEE NOTE 2 ROAD WORK W20-1 HEAD Lane Closure Operation with Temporary Traffic Barrier' (Figure TTC-20.2) END ROM WORN 0 z ¢ BEGINNING -�' ¢ ¢ AT ANGLE BREAK O_ Z a z w T OF BARRIER \\ ~> S"LINE a \ Page 6H-49 ROAD G20-2 (V) � 500' + BARRIER PANELS SEE NOTE 11 BARRIER DELINEATOR SEE NOTE 11 j TYPE B WARNING LIGHT SEE NOTE 11 BARRIER PANELS J SEE NOTE 11 BARRIER DELINEATOR O SEE NOTE 11 300' O GROUP 2 CHANNELIZING MIN. DEVICES SEE NOTE 7 o� SEE NOTE ERADICATE O 200' OF EXISTING PAVEMENT MARKING - GUARDRAIL SEE NOTE 11 O a SEE NOTES 4 0 a ILLUMINATED FLASHING SEE NOTE 11 AMBER ARROW TYPE O SEE NOTE 3 SEE 9�-SHOULDER TAPER *N6T�E 1 ® W4-2R i OPTIONAL LONG-TERM EE TRANSVERSE NOTE 1 RUMBLE STRIPS KEEP uME fxss SEE NOTE 14 i R4-V7L W9-2L MEPLE LEFT IFR SEE O NOTE 1 - - naxr - sax' uxE -y _ yF uxf W9-3R CLOSED ) LLDSEO na' SEE HUD NOTE 1 ROAD ROAD 1 RORK WORK �A1 1 1 i AHEAD W20-1 AHEAD 1: Seri Joe 1- 411/21115 2: Revision 2-7/I12018 PCMS - SEE NOTE 3 Page 6H-54 Typical Traffic Control Lane Closure on a Two -Lane Roadway Using Flaggers (Figure TTC-23.2) NOTES September 2019 Guidance: 1. Sign spacing distance should be 350'-500' where the pasted speed limit is 45 mph or less, and 500'-800' where the posted speed limit is greater than 45 mph. 2. Care should be exercised when establishing the limits of the workzone to insure maximum passible sight distance in advance of the flogger station and transition, based on the posted speed limit and at least equal to orgreater than the values in Table 6H-3. Generally speaking, motorists should have a clear line ofsight from the graphictlagger symbol sign to the flagger. 3. 'To maintain efficient trafic flow in a flagging operation on a two-lane roadway, the maximum time motorists should be stopped at a flogger station is 8 minutes for high volume roadways (average daily traffic of 500 or more vehicles per day) to a maximum of 12 minutes for low volume roadways (less than 500 vehicles per day). For additional information see Section CIE. 07 z Standard: 4. Portable Temporary Rumle Strips (PTRS) shall be used as noted in Section 617.99. 5. Flagging stations shall be located far enough in advance of the work space to permit approaching traffic to reduce speed and/or stop before passing the work space and allow sufficient distance for departing traffic in the left lane to return to the right lane before reaching opposing traffic (see Table 611-3 on Page 6H-5). 6. AS Baggers shall be state certified and have thew' certification card in their possession when performing flagging duties (see Section 6E.01, Qualifications for Flaggers). 7. Cone spacing shall be based on the posted speed and the values in Table 611-4 on Page 6H-6.' 8, A shadow vehicle with at least one high intensity amber rotating, flashing, or' oscillating light shall be parked 80'-120' in advance of the first work crew. Option: 8. A SLOW (W2l-V 10) siAzn2 maybe rquired in this area to give advance warning of the pemtion ahead by slowing aooroachinix traffic prior to reaching the flagaer station or queued traffic. Guidance: 9. If the queue of traffic reaches the BE PREPARED TO STOP (0734) sign then the signs, and if used the PTRS should be re fasted m ester dxstanees. ad1 greater 10. When a hi hw -rail crmsin exists within or upstream o the transition area and it is anticipated that g aY 8 tflee f Pm queues resulting from the Lane closure might exteml through the highway -rail grade crossing, the temporary traffic control zone should be extended so that the transition area precedes the highway -rail crossing (see Figure 7TC-56for additional information on highway -rail crossings). Standard: 11. At night, flogger stations shall be illuminated, except in emergencies (see Section 6E.08). Qrition: 12. Cones may be eliminated when using a pilot vehicle operation or when the total roadway width is 20 feet or less. 13. For low -volume situations with short work zones on straight roadways where the flag icr is visible to road Standard:' 14. When used', three portable temporary rumble (PTRS) strips shall be installed across the entire travel lane adjacent to the BE PREPARED TO STOP (W34) sign. The portable temporary rumble strips shall be monitored and adjusted as necessary during the work shift to ensure proper placement on the roadway. When the PTRS are installed, the RUMBLE STRIPS AHEAD (W20- V26) sign shall also be utilized. 1: Revision 1-4/1/2015 2: Revision 2-9/1/2019 September 2019 Lane Closure on a Two-lane Roadway Using Flaggers dFYgtire TTC-23.2j ° 9 8 S310N U ° NoUVIuYis a3eevT� ° 0 PIRG SPACING CENTER TO CENTER ( 1 POSTED/STATUTORY SPEED LIMIT S40 MPH fO FEET 41-55 MPH 15 FEET 55 MPH 20 FEET PTRS \ UNIT! SEE NOTE 4 >-nnnnnnap • O 0 0 0 0 c � OOS xsoa aros ON3 ® 02D-2 M 500 + D' - 100, BUFFER ff TABLE 6H-3 BD -120, SHADOW VEHICLE REQUIRED FBUFFER 'SEE TABLE 6H-3 50' - 100, FLAGGER STATION SEE NOTES 2, 3, 5 & 6 SEE NOTE 1 ^• Pnge 611-55 SEE \ r1/ NOTE 1 8E \/ PREPARED W3A TO STOP SEE NOTE 10 ROADWAY nnnnn� SEE NOTE 1 V CENTERLINE occur SEEN O SEE NOTE 15 PTRS SEE -m SEE NOTE 4 & 14 NOTE 1 WE W204 recso SEE AHEAD NOTE 1 ROAD mm W20-1 HEAD 1: Revision I-4/112015 2: Revision 2-91112019 SHIMP ENGINEERING LAND PLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM till p,LTH o�� O � �I U JUSHIMP a lit. 45183 �SIONAL FINAL SITE DEVELOPMENT PLAN 999 RIO ROAD ALBEMARLE COUNTY, VIRGINIA SUBMISSION: 2020.05.26 [INITIAL SDP] REVISION: 2021.01.21 [FINAL SDP] 2021.02.22 [ARB] 2021.04.13 [ACSA] 2021.05.10 [ARB] 9110161 19.006 MAINTENANCE OF TRAFFIC C13