HomeMy WebLinkAboutARB202100056 Application 2021-05-13 "Of". Albemarle Count
'' ;,, `'• '• Planning-Application
PARCEL/ OWNER,INFORMATION
TrAP• '045o,0-06-00-094A0' Own er(s):'SCi RIO1 itLL LLC
Application# I4RB2O21 OOO5G
PROPERTY INFORMATION 'I
LegalDesciiPtion I ACREAGE"PARC .qA,B,.'•C,D&E-RIOHICLSHOPPINGCENTER ,•
Magisterial Dist. Rio Land:Use Primary Cotnmercial 1..-
Current,.FD !Not.in"A;dF District .n 1 Current Zoning Prima ri Planned Development Shopping;Center ('.!"
APPLICATION INFORMATION
Street-Address Entered Ey
__ -----� ,_ __-------------_. —.---------- ___ Jennifar5O1141 ;
21
Application Type Architectural Review Board 'w, F
Project. SIGN:-T]:MAXX- DIGITAL
Received Date :05/13/.21 Received Date Final" SubmittafDate 05/24121 Total Fees
Closing File Date Submittal Date Final ' Total Paid
Revision Number
"Comments .,
1
Leg al'Ad .. .. .. _ - . . ..
SUB APPLICATION(s)
-I-SttbM plieatiO,I . .. ... Con=ment . ." . . , I
SIGN" ` O5f2-/2"3.
APPLICANT [CONTACT INFORMATION
ContactT+jpe, Nan.e Address ." „ I, , Gib/State. [" Zip . ;Phone I PhoaeCell
Owrnr`..:?}.__ri ".. Cl-RIO.HILL LLC ..300:'GnLLERLA:PARkwm 12TH '".-TL NTA.gA '30339 ';77099524434 i
?rr ry Cc.rtpct •TANYA SILVESTER!-,ANCHOR SIGN,INC 220,0 DI H R SCERAVE 6CHARLESTOfd,.SC 429405 '8435753298
Signature of Contractaror"Authoirized'Agent Date
Application and Checklist for Sign Permit
V���ApA
Part A: Applicant and Parcel Information
Project Name: TJ Maxx(TJ-0623) Address: 1850 Rio Hill Center
Tax map and parcel(s): Parcel ID#04500-00-00-094A0 Zoning: Commercial
Contact(Who should we call w/questions?)Name: Tanya Silvester Business Name: Anchor Sign, Inc.
Address 2200 Discher Avenue City Charleston State SC Zip 29405
Daytime Phone(843) 576-3298 Fax#(843) 576-7298 E-mail tsilvester@anchorsign.com
Contractor Name: Anchor Sign, Inc. Business Name:
Address 2200 Discher Ave city Charleston State SC Zip 29405
Daytime Phone(843) 576-3298 Fax#(843) 576-7298 E-mail tsilvester@anchorsign corn
Business Owner Name: SCT Rio Hill LLC Business Name:
Address 300 Galleria Parkway 12th Floor City Atlanta State GA Zip 30339
Daytime Phone(770) 995-2434 Fax#(770) 576-7298 E-mail
Part B: Determining application requirements,and fees
1. Sign Permit-Please indicate which sign type you are applying for:
❑ Freestanding or Monument Sign. $91 64
❑ If a footing is required,an additional fee is required: $32.64
❑ Wall Sign(Including property,awning,fuel pump canopy signs)• $91 64
10 Sign Refacing: $59 00
2. Electrical Permit- Will the sign be illuminated?
❑ Yes (Illuminated signs require an electrical permit and an electrical schematic.) $48.96
❑ No $ 0 00
3. ARB Review- Will the permanent sign(s)be constructed in an Entrance Corridor?
(Go to www.albemarle.org/arb for more information.)
❑ Yes (This sign will be constructed in an Entrance Corridor and it does not meet the criteria of an $129.00
approved Comprehensive Sign Plan. See ARB requirements next pages.)
❑ Yes (This sign will be constructed in an Entrance Corridor and it does meet the criteria of a Waive Fee
Comprehensive Sign Plan(CSP) Write the name of the CSP here:
See ARB requirements next pages.For more info on CSPs,go to the link at www.albemarle.org/arb.
❑ No (This sign will not be constructed in an Entrance Corridor) $0 00
FEE TOTAL(Please add all the amounts checked in sections 1
—�(3)• ���� r n $150.64
FOR OFFICE USE ONLY BP#'50706 I ' I 3'I1— I S !U ARB#CJ"-i
Fee Amount$ Date Paid By who? Receipt# Check# By
County of Albemarle Department of Community Development
401 McIntire Road Charlottesville,VA 22902 Voice: (434)296-5832 Fax: (434) 972-4126
1/2/2020 Page 1 of 4
Part C: Submittal Items Required
Note: Submittal packages must contain 4 collated copies of all information unless otherwise indicated. Additional submittal
materials may be required if review by the Architectural Review Board is necessary. Applicants will be notified if additional
materials or ARB review are required.
SECTION f: FREESTANDING, SUBDIVISION OR DIRECTORY SIGNS
A. Submittal Requirements
❑ Site plan or latest approved plat showing, to scale, the proposed location of the sign(s) with dimensions.
❑ Distance from the sign to the property lines and/or edge of the VDOT right-of-way.
❑ A footing/foundation diagram showing how the base or pole will be anchored in the ground.
❑ If the sign will be located in an easement, a letter of approval from the easement holder will be required.
❑ A to -scale color illustration of the proposed sign showing
❑ Dimensions of the sign, including overall height from the ground; cabinet size, length, width and depth; base
size, etc. (Be sure to also include these dimensions on the diagrams provided in the Sign Permit Application packet.)
❑ Proposed lettering and/or graphics in their proposed location.
❑ Entrance Corridor Requirements: If the sign is to be constructed in an Entrance Corridor, consult the Entrance
Corridor Sign Guidelines at www.albemarle.ore/arb for design requirements. Provide a color illustration of the front
and side elevations of the sign showing:
o If internally illuminated, indicate which areas of the sign are opaque and which are illuminated. Internally
illuminated cabinet signs must have opaque backgrounds. (Opaque materials don't allow light to pass through.
When lit only from behind, the color of an opaque material cannot be detected nor can objects be seen through it.)
o Identification of proposed materials and colors. Include standard color id numbers (Pantone, Benjamin Moore,
Acrylic, etc.) for all materials, text, graphics, base, faces, trim caps, returns, etc.
o If colors other than Pantone equivalents are identified, provide accurate physical samples of all colors proposed,
preferably in the material proposed. (Paint chips that accurately reflect the proposed colors are acceptable.)
o Provide a site plan showing proposed landscaping around the sign, including botanical names and planting sizes.
o Additional submittal materials may be required if review by the Architectural Review Board is necessary. (The
applicant will be notified if this requirement applies.)
B. Inspection Requirements for Freestanding, Subdivision or Directory Signs
❑ Applicant must mark the location of the property lines and the location of the sign with stakes in preparation for a
preliminary zoning inspection. (All four corners of the sign must be marked with stakes that are easily visible to all
inspectors)
❑ A preliminary zoning inspection must be completed to verify the location of the sign before the permit can be
issued.
❑ Freestanding signs are required to have footing inspections. (scheduled by applicant)
❑ Freestanding signs are required to have electrical inspections if illuminated. (scheduled by applicant)
❑ Freestanding signs are required to have final building and zoning inspections. (scheduled by applicant)
1/2/2020 Page 2 of 4
SECTION 2: WALL SIGNS
A. Submittal Requirements
❑ A drawing, to scale, showing dimensions of the sign (length, height, depth).
❑ Elevation drawing(s) or modified photograph of the entire building, to scale and in color, showing
❑ The sign location on the building, sign height above grade, and the length of building frontage. (Be sure to also
include these dimensions on the diagrams provided in Appendix B.)
❑ Sign lettering and/or graphics in their proposed location.
❑ Entrance Corridor Requirements: If the sign is to be constructed in an Entrance Corridor, consult the Entrance
Corridor Sign Guidelines at www.albemarle.org/arb for design requirements. Provide a color illustration of the front
and side elevations of the sign showing:
o Indication of sign type (channel letters, cabinet, panel, etc.).
o Indicate on the drawings the proposed materials and colors. Include standard color identification numbers
(Pantone, Benjamin Moore, Acrylic, etc.) for all materials, text, graphics, faces, trim caps, etc. For channel letter
signs, indicate on the drawing that the raceway color shall match the color of the wall to which the raceway is
attached.
o If colors other than Pantone equivalents are identified, provide accurate physical samples of all colors proposed
in the sign, preferably in the material proposed. (Paint chips that accurately reflect the proposed colors are
acceptable.)
o If externally illuminated, indicate the location of proposed light fixtures and provide manufacturer's cut sheets
describing illumination type, intensity, style, shielding, color, and height. All lighting must meet ordinance
requirements as outlined in Section 4.17.
o For internally illuminated signs, indicate which areas of the sign are opaque and which are illuminated. (Opaque
materials don't allow light to pass through. When lit only from behind, the color of an opaque material cannot be
detected nor can objects be seen through it. Internally illuminated cabinets must have opaque backgrounds.)
B. Inspection Requirements for Wall or Projecting Signs
❑ Wall and projecting signs are required to have electrical inspections if illuminated. (Scheduled by applicant)
❑ Wall and projecting signs are required to have final building and zoning inspections. (Scheduled by applicant)
SECTION 3: ILLUMINATION REQUIREMENTS
A. If the proposed sign is to be illuminated, the applicant must provide the following:
❑ Electrical permit
❑ Electrical schematic
❑ The location of proposed light fixtures identified on a plan and/or elevation
❑ Manufacturer cut sheets describing illumination type, intensity, style, shielding, color, and height. All lighting must
1/2/2020 Page 3 of 4
SECTION 4: WORK VALUATION
A. Work Valuation $
Part D: Applicant Agreement
Applicant must read and sign
• Each application package must contain 4 folded copies of all plans and documents being submitted. Only 1 set of
material/color samples is required. All submittal items become the property of Albemarle County. Applicants are
encouraged to maintain duplicate copies in their own files.
• The application package is not complete without this checklist, completed, signed, and included with the required
submittal materials indicated on the checklist.
I hereby certify that the information provided on this application and accompanying information is accurate, true and
correct to the best ofmy knowledge and beliefand contains all information required by these checklists
Signature of person completing checklist Date
Printed Name / Title Daytime phone number of Signatory
County of Albemarle Department of Community Development
401 McIntire Road, North Wing, Charlottesville, VA 22902-4596
(434) 296-5832 Tel, (434) 972-4126 Fax
www.albemarle.org
1/2/2020 Page 4 of 4
3/3112021
License lookup: license Search Results
DPOR License LOOkUp License Number 2705048147
License
Details
Name
ANCHOR SIGN OF VIRGINIA INC
DBA Name
ANCHOR SIGN INCORPORATED
License Number
2705048147
License Description
Contractor
Firm Type
Corporation
Rank t
Class B
Address
2200 DISCHER AVENUE, NORTH CHARLESTON, SC
29405
specialtie32
Billboard / Sign (BSC)
Initial Certification Date
1999-03-10
Expiration Date
2023-03-31
Refer to the Statutory Definitions (http://law.lis.virginia.gov/vacode/title54.1/chapterl l /section54.1-
1100n for descriptions of the rank or class of license (A, B, or C) that determines the monetary limits on
contracts/projects.
Refer to the Classification Definitions (http:/Als.virginia.gov/cgi-bin/Iegp6G4.exe?000+reg+18VAC50-22-
20) and Specialty Definitions (http:/4is.virginia.gov/cgi-bin/Iegp604.exe?000+reg+18VAC50-22-30) for
detailed definitions of these classifications and specialties.
The data located on this website are not the public records of the Department of Professional and Occupational
Regulation (DPOR). All public records are physically located at DPOR's Public Records Section: 9960 Mayland
Drive, Suite 400, Richmond, VA 23233. While DPOR works to ensure the accuracy of the data provided online, the
data available on these pages are updated routinely but may not be up to date at all times (due to document
processing delays, technical maintenance, etc.).
DPOR assumes no liability for any errors, omissions, or inaccuracies in the information provided or for any
reliance on data provided online. While DPOR has attempted to ensure that the data contained herein are
accurate and reflect the status of its regulants, DPOR makes no warranties, expressed or implied, concerning the
accuracy, completeness, reliability, or suitability of this data. if discrepancies or errors are discovered, please
inform DPOR so that appropriate action may be taken.
DPOR License Lookup build 1,472 (built 2021-02-15 10:16:48).
dpo ebApw.virginia.gov/U"nseL,Dokup✓Uce=Detail 1/I
TOJOMM);W(
SIGNB TJ Maxx
D/F Under Canopy
Internally Illuminated w/ LEDs
2.50
Bottom of Sign to Grade = 8'-0"
SIGN C TJ Me.
New Acrylic Panel w/ Applied Vinyl
23" x 48`
21"x 44"
7.67
Rio Hill Shopping Center
TO)02/i812B21
Y
/`
Client: TJ Mexx
01=1321
odinal Rendering
So
n,, re�o9 r u. nmpxly or Aornor
sreA m� n r°' m• �'%n'• °%• =i
son n.,y
.•„ a•aoe.
n� we a.••i�'•a � m ee
., proruo eo,or shbsoda r
mm �ma.mm
012M!321
Atlded mtl note to elevation e. Addetl m setl photo to Sign C.
KB
Site #: TJ-0623
Revised Sign C an Site Ma & Updates] Sign C S
LC
Address: 1980 Rio Hill Center
03 laD21
Revised site ma location and existing idum fir
BA
Charlottesville, VA 22901
Rio Hill Shopping Center
PP 9
IW lWD21
Updated Sign dime
NW
SIGN B TJ Maur
D/F Under Canopy
Intemally Illuminated w/ LEDs
2.50
Bottom of Sign to Grade = 8'4r
Front Elevation (Southeast)
Scale: 3132" = V-0'
Under Canopy Sign
(Centered Over Entrance)
Allowable Square Footage this Elevation ®'
r
Actual Square Footage this Elevation: MEN
TojeMC13Xre
Client: TJ Mau
OV192B21
On inaI Rendering
So
m - n. ,m
re sreanoeoelevaf9B2
M
en
mime ray. a�Po�m ma,�u=:
resamme �nm.usm�.,:
01@BVF
Aetlretl tion aAtltletl m setl photo to signC.
KB
Ste#: TJ-0623Sift.
021Re
nCon Ma &U signtlaeCS
Addss. 1980 Rio Hill Center
0.i3Vag21
cture r on
Re setl ste me location and ensnn fi
BA
Charlottesville, VA 22901
stedS nC dime
NW
Rio Hill Shopping Center
SIGN A 54'TJ Mane
IndiNdual Channel Letters
Internally Illuminated w/ LEDs
162.50
Top of Sign to Grade = 20'4 3/4"
Bottom of Sign to Grade=14'-61/Y
SIGN MUST BE CENTERED HORIZONTALLY
AND VERTICALLY ON THE FACADE
r-
Red LEDs
(3) PL-PS-12-60 Transformer @ 1.1 amps
Total Amps: 3.3
(1) 20 amp 120V Circuit Req. (DUMB
This sign is to be installed in accordance with
the requirements of Article 600 of the National
Electrical Code.
1) Grounded and bonded per NEC 600.7/NEC 250
2) Existing branch circuit in compliance with
NEC 600.5, not to exceed 20 amps
3) Sign is to be UL listed per NEC 600.3
4) UL disconnect switch per NEC 600.6- required per
sign component before leaving manufacturer'
'For multiple signs, a disconnect is permitted but
not required for each section
Sign Layout Detail
Scale: 1/4" = V-0"
1. Existing Facade: EIFS I Plywood I Metal Studs
2..040" Pre -finished Maxi Brite Black aluminum returns
3. 1" Pre -finished Wagner Black trimcap bonded to face and #8 pan head screws to returns
4..080"Aluminum backs fastened to retums w/ 1/2" 18 gauge staples. Seal w/ VOC compliant 360 white latex
caulk to prevent moisture penetration. (interior of sign can painted white for maximum illumination)
5. White LEDs
6. 3/16" RH #2793 red acrylic faces
7. Disconnect switch UL Outdoor rated toggle type w/ neoprene boot per NEC 600-6
8. Primary electrical feed in UL conduit / customer supplied UL junction box
9. Transformers within UL enclosure (removable lid), 1/4" x 1' min screws
10. 2" x 2" x 3/16 galvanized angle mounting clips w/ #12 sheet metal screws
Section 0 LED Channel Letter
Front -lit (Remote) Scale: N.T.S.
Y
/`
Client: TJ Mary
01=G21
Origin Rendering
So
m�. re�e.noeum.n�n=Mmno=no.
S, ��� n is rn m. a ti a ... of
"It iz. as
n o�s��m dr= I,e � t o =1 L r •
mmm °e°,°o=nw,o9,e,;;-. rr
D1(79@D21
Added red note to elevation a. Atltletl m setl photo to Si n C.
Ka
Site #: TJ-0623
D2/ia12D21
Revised S' n C an Site Ma & updated sign C S
LC
Address: 1980 Rio Hill Center
D3/31=1
Revised site me location and enstin idum fir
BA
Charlottesville, VA 22901
0.1/1WD21
U atetl Si nCtlime
NW
Rio Hill Shopping Center
SIGNB TJ Mary
D/F Under Campy
Intemally Illuminated w/ LEDs
2.50
Bottom of Sign to Grade = 8'-0'
TejeMCY
/`
Client: TJ Mau
01=1321
Origin Rendering
So
IDIsreN•no9utlnpmpeey WFornor
s'a "ten r°'°'•�'%'°•°%•_�
son iz_.a u••n•ro .m== i
.•„ a•noe. m ..,1 / r
n-p we wgln•I as am �1 m ee (.
m/m��lmamosg�°i2 rr
mm �ma.mm��
0129I2B21
Added red note to elevation e. Addetl m setl photo to SignC.
KB
Site#: TJ-0623
.1321
Revised S' n C an Bite Ma & U d.aal Sinn C S
LC
Address: 1980 Rio Hill Center
03/31Y2B21
Revised site me location and enstin icture fir
BA
Charloftesville, VA 22901
IW/1Y2B21
Updated Si nCtlime
NW
Rio Hill Shopping Center
PP 9
&SIGN
Ne� "lie Panel wl Applied Vinyl
l Size:
Viewable Size:
Square Footage:
Panel Replacement on Existing D/F Pylon
QTY 2 (1 SET) scale: 1" =1'-0"
1. #7328 White Acrylic Panel
2. First Surface Applied Vinyl to match PMS Cool Gray 8C
3. Existing 1 1/2" Rretainers
Proposed
Existing
Client: TJ Maxc
01f1212B21
Cd inal Render,
So
IDIs reN• , N psss ly W A-h,,
s'a "ten r°'°'•�'%'°•°%•_�
am•i as amV1tee/`
;m-�sgm°
ma�. �a ma.mm��
M
012121
Atltletl--d note to elevation e. Added m setl photo to SignC.
KB
Site #: TJ-0623
02/18I2021
Revisetl S' n C on Site Ma & U datetl Si n C S
LCTO)Y
Address: 1980 Rio Hill Center
0.&/31nB21
Ravisetl site ma locationand enstin idumfir
BA
Charlottesville, VA 22901
Rio Hill Shopping Center
PP 9
@ViY2B21
U ated SinC dime
NW