HomeMy WebLinkAboutSDP202100022 Plan - Revision 2021-05-19WALL A DRAWING INDEX Sheet 1 Site Plan 2 General Notes/ Design Parameters 3 Details 4 Wall A - Sta. 0 to 5ta. 78 Wall B - Sta. 0 to Sta. 48 5 Wall C - Sta. 0 to Sta. 55.5 \nkifL:E MD rry _ SITE PLAN N W E Scale: I" = 100 FT 0 50 100 42" Tall Safety Handrail or Fence w/ Sleeve -It SW Fence -Post Anchoring System Lap Unit Secure to Top Unit w/ Concrete Adhesive Anchor Diamond Pro Units Drainage Aggregate Min 12" Thick VDOT No. 57 Stone Weephole w/Wall Drain Pro Daylight Pipe Through Wall 40' OC Spacing (Typ.) Compacted Bockf ill Crushed Stone Leveling Pad 6" Thick x 24" Wide Non -Woven Filter Fabric Mirafi 140N or Equivalent 6eogrid Reinforcement (Typical) Refer to Wall Profile for Geogrid Type, Geogrid Length (GL) and Location y-24" Vertical Spacing (TYp') Retained Soil Reinforced Fill 4" Dia. Drain Pipe Granular or Low Plasticity Soil (See Drain Detail) Compact To Min 95% Standard GL Proctor Density 10 _I See Wall Profile TYPICAL RETAINING WALL CROSS SECTION (Not to Scale) EL 12-1/2" i ----------------- 0 0 12" _ Rear Lip 18" 1" Setback 8-1/2" 8" f Anchor Diamond Pro Segmental Retaining Walls Albemarle Business Campus - Block 5 �� MICMAEL .0 Albemarle County, Virginia We.Oi124; Site Plan Adapted From the Grading Plan, Sheet No. C7, 4/9/Z/ Dated October 5, 2020 (Rev. 4 - 4/5/21), Prepared By 5himp Engineering, P.C. Site Plan For Illustrative Purpose. Approx. Scale: 1" = 100 FT fs��NAL 4 ir)IN t�tr Y Straight Split Face ANCHOR DIAMOND PRO UNIT (Not to Scale) Circeo Geotechnical Engineering, P.C. I 5956 Buckland Mill Road Roanoke, Virginia 24019 Phone:(540) 366-2379 Project No. I RW-2554 NOTES: DESIGN PARAMETERS: 1.0 STRIP VEGETATIVE AND ORGANIC SOIL FROM THE WALL AND GEOGRID ALIGNMENT. 2.0 BENCH CUT ALL EXCAVATED SLOPES. 3.0 DO NOT EXCAVATE BEYOND EXCAVATION LINES SHOWN ON PLAN UNLESS DIRECTED BY THE GEOTECHNICAL ENGINEER TO REMOVE UNSUITABLE SOIL. 4.0 CONTRACTOR SHALL ENSURE TEMPORARY EXCAVATIONS ARE STABLE AND PROVIDE EXCAVATION SUPPORT IF NEEDED. 5.0 GEOTECHNICAL ENGINEER SHALL VERIFY FOUNDATION SOILS AS BEING COMPETENT PER THE DESIGN PARAMETERS. 6.0 LEVELING PAD SHALL CONSIST OF COMPACTED SAND, GRAVEL, OR COMBINATION AND SHALL BE A MINIMUM 6-INCH THICK LAYER WITH A MINIMUM WIDTH OF 24 INCHES. 7.0 A 4-INCH-DIAMETER SLOTTED DRAINAGE PIPE SHALL BE INSTALLED BEHIND THE WALL AND CONNECT TO WEEPHOLES INSTALLED AT THE BASE OF THE WALL (40 FEET ON CENTER) AND EXTEND BEYOND THE FINAL GRADE TO DAYLIGHT (SEE DRAIN DETAIL). 8.0 DRAINAGE AGGREGATE AND UNIT (CORE) FILL SHALL CONSIST OF CLEAN ANGULAR GRAVEL (VDOT NO.57 STONE), MEETING THE FOLLOWING GRADATION AS DETERMINED IN ACCORDANCE WITH ASTM D-422. SIEVE SIZE PERCENTAGEPA55ING 1-112 INCH 100 1 INCH 95-100 1/2 INCH 25 - 60 NO.4 0-10 NO. 8 0-5 9.0 GEOGRIDS SHALL BE LAID HORIZONTALLY ON COMPACTED BACKFILL FOR THE REQUIRED GE06RID LENGTH (GL) IN THE TENSILE STRENGTH DIRECTION (PERPENDICULAR TO WALL FACE) NOTED ON THE WALL PROFILE. THE GEOGRID SHALL BE PLACED WITHIN ONE INCH OF THE FRONT FACE OF THE UNIT BELOW AND EXTEND HORIZONTALLY OVER COMPACTED FILL. 10.0 ANCHOR DIAMOND PRO UNITS MOLDED DIMENSIONS SHALL BE 8 INCHES HIGH BY 18 INCHES LONG BY 12 INCHES DEEP AND SHALL NOT DIFFER MORE THAN + 1/8 INCH IN ANY DIMENSION. 11.0 A 1-INCH SETBACK PER UNIT (REAR LIP) SHALL BE MAINTAINED FOR PROPER BATTER (I.E. 7 DEGREE CANT FROM VERTICAL). 12.0 GEOGRIDS SHALL BE PLACED WITHIN 1 INCH OF THE FRONT FACE OF THE UNITS AND GEOGRID5 PULLED TIGHT (AFTER PLACEMENT OF THE NEXT COURSE OF BLOCK UNITS) TO REMOVE SLACK AND TO INTEGRATE GEOGRIDS AND UNITS. 13.0 FIELD ADJUSTMENTS OF BLOCK ALIGNMENT MAY BE MADE ON NON -REINFORCEMENT LAYERS WITH THE USE OF SHIMS OR ASPHALT SHINGLES TO RAISE ONE COURSE OF BLOCK BY A MAXIMUM OF 1/4 INCH VERTICAL HEIGHT. 14.0 REINFORCED FILL SHALL CONSIST OF GRANULAR SOIL FILL 1 BUILDING CODES: 2015 VIRGINIA UNIFORM STATEWIDE BUILDING LODE (USBC) WITH U5C5 SOIL TYPES GP, 6W, GM, 6C, 5W, SP, SM OR 5C AND 2015 INTERNATIONAL BUILDING CODE (IBC). WITH A MINIMUM ANGLE OF INTERNAL FRICTION, OF 28 DEGREES 2 THE WALL PROFILES ARE BASED ON THE GRADING PLAN, SHEET NO. C7, AS OUTLINED IN DESIGN PARAMETERS - NOTE 5. DATED OCTOBER 5, 2020 (REV. 4 - 4/5/21), PREPARED BY SHIMP ENGINEERING, P.L. MAXIMUM PARTICLE SHALL BE LIMITED TO 4INCHES IN DIAMETER. 3 WALL DETAILS SHOWN ON THIS PLAN ARE FOR ANCHOR DIAMOND PRO THE FINE FRACTION (MINUS NO. 40 SIEVE) SHALL HAVE A MAXIMUM SEGMENTAL RETAINING WALL (SRW) UNITS MEETING THE NATIONAL LIQUID LIMIT (LL) OF 40 AND A MAXIMUM PLASTICITY INDEX (PI) CONCRETE MASONRY ASSOCIATION (NCMA) CRITERIA FOR SRW WALL SYSTEMS. OF 20. THE BACKFILL SHALL BE FREE OF DEBRIS AND ORGANIC MATTER. 4 ENGINEERING ANALYSIS BASED ON USE OF STRATAGRID 56200 GEOGRIDS. LOW PLASTICITY SILT OR CLAY (ML-CL) CAN BE USED SUBJECT TO OTHER COMPATIBLE GE06RID5 MAY BE SUBSTITUTED WITH THE APPROVAL APPROVAL BY THE GEOTECHNICAL ENGINEER. OF THE WALL DESIGN ENGINEER. HIGHLY EXPANSIVE SOILS (MH-CH) SHALL NOT BE USED IN THE 5 THE DESIGN OF THE SEGMENTAL RETAINING WALL (SRW) REINFORCED FILL ZONE. ASSUMES THE FOLLOWING PARAMETERS: Ym, Moist FRICTION 15.0 REINFORCED FILL SHALL BE PLACED IN 8-INCH LIFTS AND SOIL SOIL UNIT WEIGHT ANGLE COHESION COMPACTED TO A MINIMUM OF 95% OF MAXIMUM STANDARD CONDITIONS Type (PCF) (DEG) (PSF) PROCTOR DENSITY (A5TM D-698) AND WITHIN + 3 PERCENTAGE REINFORCED FILL Granular or Low Plasticity Soil 120 28 0 POINTS OF OPTIMUM MOISTURE CONTENT. COMPACTION TESTS SHALL RETAINED SOIL Silt to Sandy Silt 120 28 0 BE PERFORMED AS THE WALL IS INSTALLED. COMPACTION WITHIN FOUNDATION SOIL Silt to Sandy Silt 120 28 100 3 FEET OF THE WALL SHALL BE LIMITED TO HAND -OPERATED EQUIPMENT. 6 SOIL STRENGTH PARAMETERS ARE BASED ON USE OF GRANULAR SOIL FILL 16.0 A VIBRATORY PLATE TAMPER SHALL BE USED TO DEN5IFY OR LOW PLASTICITY SOIL IN THE REINFORCED FILL ZONE. NO.57 STONE. COMPACTION TESTS CAN BE WAIVED ALL ENGINEERED FILL SHALL BE PLACED IN MAXIMUM 8-INCH LIFTS WHERE NO.57 STONE IS USED AS REINFORCED FILL. AND EACH LIFT I5 COMPACTED TO A MINIMUM OF 95% OF 17.0 CONTRACTOR SHALL SLOPE SITE GRADES TO DIRECT SURFACE MAX. STANDARD PROCTOR DENSITY, AND WITHIN+ 3 PERCENTAGE POINTS RUNOFF AWAY FROM WALL AT END OF EACH DAY TO AVOID OF OPTIMUM MOISTURE CONTENT, USING PORTABLE COMPACTION EQUIPMENT. WATER DAMAGING THE WALL WHILE UNDER CONSTRUCTION. 18.0 ANY SURFACE DRAINAGE FEATURES, FINISH GRADING, PAVEMENT, DO NOT USE HIGH PLASTICITY CLAY (CH-MH), ROOTS OR TOPSOIL IN REINFORCE OR TURF SHALL BE INSTALLED IMMEDIATELY AFTER THE WALL IS COMPLETED. ZONE. ANY SOFT, SATURATED SOIL ENCOUNTERED IN 5UBGRADE SHALL BE 19.0 IF SITE AND SOIL CONDITIONS, WALL GEOMETRY, OR WALL UNDERCUT AND REPLACED WITH CRUSHED STONE TO STABILIZE THE LOADING ARE DIFFERENT THAN THE DRAWINGS AND THE DESIGN FOUNDATION 5UB6RADE OR AS DIRECTED BY THE GEOTECHNILAL ENGINEER. PARAMETERS, THE CONTRACTOR MUST CONTACT THE WALL DESIGN ENGINEER PRIOR TO PROCEEDING WITH THE CONSTRUCTION OF THE WALL. WALL A - MAX. WALL HEIGHT = 10 FEET (INCLUDING EMBEDMENT) WALL B - MAX. WALL HEIGHT = 2 FEET (INCLUDING EMBEDMENT) 20.0 DETAIL FOR PEDESTRIAN GUARD POSTS AT THE TOP OF THE WALL WALL C - MAX. WALL HEIGHT = 4 FEET (INCLUDING EMBEDMENT) IS PROVIDED FOR PLACEMENT OF POSTS BEHIND THE WALL (SEE SHEET 3 OF 5). 1" Setback FRONT SLOPE = LEVEL TO MAX. 3H:1V BALKSLOPE BEHIND THE WALL = LEVEL SURCHARGE AT TOP OF WALL = 100 P51F MIN FACTOR OF SAFETY (SLIDING) = 1.5 MIN FACTOR OF SAFETY (OVERTURNING) = 2.0 )pen Cells MIN FACTOR OF SAFETY (BEARING CAPACITY) = 2.0 Filled With Stone) DESIGN SOIL BEARING PRESSURE = 1,500 PSF Albemarle r_�CiWV Circeo1" Rear Lip < = G:0technical I ( O NOWr Engineering, P.0 No. 011246 UNIT CONNECTION DETAIL (Not to Scale) A. Scale Date: 5956 Buckland Mill Road Roanoke, Virginia 24019 Phone:(540) 366-2379 F 1 Project No. I RW-2554 r�r WALL A Abut Wall A to Building 0 t Q O t } Additional Weephole @ Low Point — 464 462 n} 1J1 tw 452 0 450 Surcharge = 100 psf TOC = 454.33 TOW = 454.01 GL=IOFT TOC = 453.67 TOW = 453.33 —■ •gm �.� • -----■-----'�■---------- �---■----- ------� -- Tom_=M=`�-I® -------■-- IIIIwo■ d 446 �++ ' _' =lO FT ..... I ' BOW = 450.00 444 I GL=8FT BOW =448.00 GL=10FT GL=10FT 6"Thick Stone gOW=446.00 I Proposed Grade at Bottom of Wall 4344 8 BOW = 444.67 Leveling Pad I i 436 BOW = 444.00 (Low Point) Drain Pipe to Daylight - 40 FT O.C. (Typical) 434 F SO 20 30 40 48 60 r64 70 7S Station (ft) I� GL = 10 FT — I GL = 8 FT GL = 6 FT cif GL = 4 FT WALL B . -------■-----■n---- �ru---- Vr■:ar---- c:rm---- • • • F•ME -- • ---■---- -- --/ —u■----1 r■■�---- —u■----1 ---- -••----••----___--- ••----------I ■----- -I�--� --••-� ---- -•---'---- ---- ---1=--== 1■---I---■-I��-� P.M.. � _ _ 1 _ _ _ _ _ T �� Ina-_---r-.==� I IM 6" Thick Store BOW 453.33 Leveling 'a El 10 LEGEND ® Cap Unit (4" Height) 0 Anchor Diamond Pro Units (8" Height x 18" Width) Leveling Pad (Min. 6" Thick x 24" Wide Crushed Stone) TOC Top of Cap Unit TOW Top of Wall (Excluding Cap Unit) BOW Bottom of Wall (Including Embedment) — 200 • — • StratoGrid 56200 0 4" Drain Pipe to 457.00 = 456.67 Tie Into Grade Along �Sirlewnik (EL. 457 +) 00 3 } W W = 454.67 ottom of Wall 20 30 40.5 Station (ft) I — No Geogrid I RETAINING WALL A Sta. 0 to Sta. 78 RETAINING WALL B Sta. 0 to Sta. 48 Viewed From Front Face of Wall Design Soil Bearing Pressure = 1,500 WALL A w/ 42" Tall Pedestrian Guard Sta. RET-r\ )RAIL Sta.60 Ht` a, Filter Fabric VDOT No. 57 Stone 0 0 0 0 0 0 0 SRW Unit Ex. Structure t Abutment, Alternate Full Unit with Half Unit Every Other Course. Do Not Attach to Structure. } 15 RETAIN 55 W. 42" Sta.78 o MAX H /40.5- Sta 20 WA - A"rI ,i i v _ in dz \ 1\ ENLARGED SITE PLAN . No. 02124: 4/yjz ��ONAL I WALL ABUTMENT DETAIL (Not to Scale) C""— 0 N j Sta. 20 .4e-x Sta. RETAIL 0 TENANT 2,298 SF 40 LP 53-- 38 5 FFE-4�4.00 ,.. s BLOCK ' G 0ALL WALL B M ANDRAI w/ 42" Tall Pedestrian Guard J c 4 1, Sta. 0 400. _ Scale: 1" = 20 FT 0 10 20 Immm - Rlnrk 5 Circeo 5956 Buekland Mill Road Geotechnical _ Engineering, P.C. Roanoke, Virginia 24019 j Phone:(540) 366-2379 Scale: H' ' = 2 rr. V: 1"= to ft. Project No. RW-2554 Date: 04/09/21 Revision: --- Sheet 1 4 of 5 WALL C FE Cut Geogrid Around Manho Min 24" 464 462 460 458 456 } 454 w. 452 0 450 448 N 446 W 444 442 440 438 436 434 —Manhole Behind Wall C =mmmmmm �ht at Each End of Tr ME IN 0 0 0 I IN MIN IN IME -------------0 ■- �— — . • - . - . ii �■ �■ ■ • -- • --■--AI---N -- --• --■-•I—M --■-r�—..�.— orm- --------------------------- a■—W—� ai Iv= 6" Thick Stone I BOW= 442.00 (Low Point) Proposed Grade at Bottom of 'W El10 20 30 40 Station (ft) I I� GL=4FT Manhole Use All No. 57 Stone In Reinforced Zone z o Around Storm Structure Ern N � J L � Min 24" 7 d L _ i■■■■■■■■■■■■■in 011■■f���������1 ■■■■■■■■■■■■■ ■� ■■■■■I■■■■■■■■■I I■■■■■■■■■■■■■ ■U■■■■■■■■■■■■■I■l�■■■■■■I • ' . AIROUND MANHOLE (Not to Scale) ® Cap Unit (4" Height) 0 Anchor Diamond Pro Units (8" Height x 18" Width) Leveling Pad (Min. 6" Thick x 24" Wide Crushed Stone) TOC Top of Cap Unit TOW Top of Wall (Excluding Cap Unit) BOW Bottom of Wall (Including Embedment) 200 • — • StratoGrid 56200 GL 0 4" Drain Pipe to nch Drain 46.33 46.00 V u) r } W BOW = 443.33 = 442.00 (Low Point) ill 50 55.5 i 443.33 454.00 464:67 IGHT: 43' SEGMENTAL BLOCK RETAINING WALL MAX HEIGHT 2.7' ENLARGED SITE PLAN ATOR B -,,WALL C14Z� 4263 w/ 42" Tall Pedestrian Guard 91 742�s 8 S ____"R - s _s Scale: 1" = 20 FT Illf i �r 0 10 20 Carle Business Campus - Block 5 Albemarle County, Virqinia Circeo Geot ineeral RETAINING WALL C a MiMIR CIRI p Engineering, P.C. Sta. 0 to Sta. 55.5 No. oilY45 �: 1"= 10 ft. Viewed From Front Face of Wall04/v/Z/ Scale: V: 1"= loft. S�ONAL �� Date: 04/09/21 [Design Soil Bearing Pressure = 1,500 psf] I I Revision: --- 5956 Buckland Mill Road Roanoke, Virginia 24019 Phone:(540) 366-2379 Project No. I RW-2554