HomeMy WebLinkAboutSUB202100094 Approval - Agencies 2021-05-03 (3)OSE/PE Report for:
Construction Permit: Certification Letter: Subdivision: �X
Property Location:
911 Address: (NOTASSIGNED) City: Charlottesville, VA
Lot: 150 Section: Subdivision: Ashcroft Phase II, Section 9
GPINor Tax Map #: 78A - 01- Phase II - Section 9 - 150 Health Dept. ID #:
Latitude:
Applicant/Client Mailing Address:
Longitude:
Name: R.L. Beyer Construction
Address: 660 Hunters Place, Suite 101
City: Charlottesville, VA State: VA
Prepared By:
OSE Name: Stephen B. Vargo
Address: P.O. Box 187
City: Scottsville
PE Name: n/a
Address: n/a
City: n/a
Date of Report:
OSE/PE Job #:
Jan. 22, 2020
n/a
Zip Code: 22911
License #: 1940-0001113
State: VA Zip Code: 24590
License #:
State: n/a Zip Code: n/a
Date of Revision # 1:
Date of Revision #2:
Contents/Index of this report (e.g. Site Evaluation Summary, Soil Profile Descriptions, Site Sketch etc.)
SOIL SUMMARY (1) CERT. STATEMENT (6)
SOIL PROFILES (2)
ABBR. DESIGN (3)
SAN. SURVEY (4)
PLAT (5)
Certification Statement:
I hereby certify that the evaluations and/or designs contained herein were conducted in accordance with the Sewage Handling and Disposal
Regulations (12VAC5-610), the Private Well Regulations (12 VAC5-630) and all other applicable laws, regulations and policies implemented
by the Virginia Department of Health. I further certify that I currently possess any professional license required by the laws and regulations of
the Commonwealth that have been duly issued by the applicable agency charged with licensure to perform the work contained herein.
XIThe work attached to this cover page has been conducted under an exemption to the practice of engineering, specifically the
exemption in the Code of Virginia Section 54.1-402.11
I recommend that a: construction permit 0
subdivision approval 0
OSE/PE Signature:
=6 1
certification letter0
be: issued �X
denied
Date: Jan. 22, 2020
Soil Summary Report
General Information
Date: Jan. 22, 2020 Submitted to: Albemarle Health Department
Applicant: R.L. Beyer Construction Phone: 434 977-0778
Address: 660 Hunters Place, Suite 101
Charlottesville, VA
Owner: R.L. Beyer Construction
Address: 660 Hunters Place, Suite 101
Charlottesville, VA
Location: W. Side Summit Ridge Trail
Tax Map: 78A - 01 - Phase II - Section 9 - 150 Subdivision: Ashcroft Phase II, Section 9
Block: Section: Lot: 150
SOIL INFORMATION SUMMARY
1.
Position in landscape satisfactory YES XX NO=
Describe Wooded Piedmont Sideslope
2.
Slope 19 %
3.
Depth to rock or impervious strata Max. 65 Min 65 None
4.
Depth of seasonal water table (gray mottling or gray color)
YES inches
NO X
5.
Free water present YES NO FX
6.
Soil percolation rate estimated YES X Texture Group III
NO *Estimated Rate: 70
*All applicable regulations as well as the specific soil and site
conditions (including the trench sidewalls) were taken into
7.
Permeability test performed Yes account when the estimated percolation rate was assigned.
No X
If yes, note type of test performed and attach:
X
Site Approved: Primary drainfield to be placed
at a depth of. 30 inches at site delineated on permit
If required, reserve drainfield to be placed
at a depth of. 30 inches
Site Disapproved
Reasons for rejection:
1.
Position in landscape subject to flooding or periodic saturation
2.
Insufficient depth of suitable soil over hard rock
3.
Insufficient area of acceptable soil for required drainfield, and/or Reserve Area
4.
Rates of absorption too slow
5.
Insufficient area of acceptable soil for required drainfield, and/or Reserve Area
6.
Proposed system too close to well
7.
Other, Specify
(attach additional pages if necessary)
Iof6
2 of
:.2
Soil Profile Description Report
Date of Evaluation:
Jan. 22, 2020 Tax Map: - 01 - Phase II - Section 9
Where the local health department conducts the soil evaluation, the location of profile holes may be shown on the schematic
drawing on the
construction permit or the sketch submitted with the application. If soil evaluations are conducted by a private soil scientist, location of profile
holes and sketch of the area investigated including all structural features, i.e., sewage disposal systems, wells, etc., within 100
feet of site (see
Section 4) and reserve site
shall be shown on the reverse side of this page or prepared on a separate page and attached on this form.
See application
sketch page See construction permit X See attached sketch
Boring
Horizon
Depth Description of soil color, texture, etc.
Texture Group
N
No.
1 Ap
0-4 7.5YR 4/3 Loam, Friable
IIB
BA
4-9 10YR 5/6 Clay Loam, Friable
HI
Bt
9-65 7.5R 4/4 Silty Clay Loam, Firm
III
2 Ap
0-4 7.5YR 4/3 Loam, Friable
IIB
BA
4-11 10YR 5/6 Heavy Clay Loam, Friable
HI
Bt
11-65 1OR 5/6, few IOR 7/4 (parent) Silty Clay Loam, Firm
III
3 Ap
0-3 10YR 3/3 Loam, Friable
UB
Bt
3-65 1OR 5/6 Silty Clay Loam, Firm
IN
4 Ap
0-4 10YR 3/3 Loam, Friable
UB
BA
4-8 10YR 5/6 Clay Loam, Friable
IN
Bt
8-65 1OR 5/6 Silty Clay Loam, Firm
IN
3of6
Abbreviated Design Form
78A - 01- Phase H - Section 9 -150
Aqua Safe system - Primary & Reserve
Design Basis
1. A. Estimated Percolation Rate (minutes per inch)
B. Recommended trench bottom (inches)
C. Depth to restrictive feature or to limit of evaluation if none encountered (inches)
D. Minimum separation distance required (may be impacted by perc rate)
E. Separation distance in inches provided in design (1C-113)
F. Minimum trench bottom is 10 inches, unless slope is > 10%, then
[(% slope x .01 x trench width in inches) + 10 inch minimum]
G. Is the slope greater than 10%?
H. If slope is greater than 10%, does greater than 24" to rock exist below trench bottom
I. If slope is greater than 10%, and there is greater than 24" to trench bottom,
add 1' to minimum center to center spacing, beginning at 20% slope and continue
for each 10% slope increase above 20%. If trench bottom is less than 24" above
rock, add I'to the minimum center to center spacing beginning at 10% slope and
continue for each 10% slope increase above 10%. (For center to center spacing
increase above the minimum, see the box at right.)
2. Square feet required:
Loading rate: 0.64 gpd/sq.ft.
Square footage required per bedroom: (150 gpd/bedroom) / ( 0.64
3. Number of bedrooms
Area Calculations
4. Trench length
Length of available area
5. Trench width
6. Number of trenches
7. Center -to -center spacing
91
a
A. Width required [(# of trenches - 1) * (center spacing)] + (trench width)
B. Width of available area
Total square footage required (trench bottom s.f./bedroom) * (# of bedrooms)
10. Square footage in design (trench length)*(trench width)*(# of trenches)
11. Is a reserve area required? DYes n/a No
gpd/sq.ft.)
Percent required: 100%
Percent available: 100% Available in lower portion of area with (5) 65' pre-treated trenches
4 of
71WE B
. LLC
ON
ARE
I '
i
I
pFFSITE FEATURES NITHIN,20()1
IIIN ON THIS SKETCH
I '
i
I �
I
i
;
I
LOT 149
o l
LOT 150
I '
I
I '
i
i
•PUBLIC HATER AVAILABLE
;
----------
OFT law „SOD'
147
I I ii I
I I� I ii I
I
I
�I I
I
II I ii I
I I I ii I
.I I ii I
} 20 ACSA WA TERLINE -`
+ 08 4028 P ESMT.
6 718 „�ru
iof6
6of6
Certification Statement
County: Albemarle
Property Identification: 78A - 01- Phase H - Section 9 -150
Submitted by:
R Vargo. OSE N-o 1940-0001113
This is to certify according to subsection 32.1-163.5 of the Code of Virginia that work submitted for the referred
property is in accordance to and complies with the Sewage Handling and Disposal Regulations of the Virginia
Department of Health.
I recommend a Subdivision be approved.
Date: Jan. 22, 2020
Stephen B. Vargo, VA OSE Ng 1940 0001113