HomeMy WebLinkAboutSUB202100089 Review Comments Preliminary Plat 2021-06-04From: Victoria Fort <vfort@rivanna.org> Sent: Thursday, June 3, 20218:36 PM To: Bill Fritz <BFRITZ@albemarle.org> Cc: Dyon Vega <DVega@rivanna.org>; Scott Collins <scott@collins-engineering.com>; Richard Nelson <rnelson @servicea uthority.org> Subject: SDP202100044 Victorian Heights Initial Site Plan and SUB202100089 Victorian Heights Preliminary Subdivision Plat CAUTION: This message originated outside the County of Albemarle email system. DO NOT CLICK on links or open attachments unless you are sure the content is safe. M1 RWSA has reviewed the initial site plan and preliminary plat for Victorian Heights as prepared by Collins Engineering and dated 4/5/2021 and has the following comments: General Comments: RWSA is in discussions with the applicant regarding the acquisition of a permanent water line easement along Woodburn Road for the future construction of a new 36" raw water main. The proposed easement is shown on the plans on sheets 3 & 4 as "proposed RWSA utility easement'. RWSA will continue to coordinate the details of this new easement with the applicant. Sheet No. 2: 1. Show and label the RWSA 3W water main (ductile iron) and 24" water main (cast iron), which run parallel to the property line between TMP 45-68C2 & 45-68E. Please also show the 24" interconnection between these two mains. 2. Show the two existing RWSA water valves located at an interconnection between these two water mains. 3. Show and label the RWSA 12" water line (ductile iron) running parallel to Woodburn Road on TMP 45-68C2. 4. Show and label existing ACSA water service lines near the frontage of 45-68E on Woodburn Road. S. Remove temporary construction easement (DB 1439, P 196), as this is no longer in effect. Sheet No. 3: 1. RWSA is concerned about the proximity of units in buildings 2, 3, and 6 to the existing 24" and 30" finished water lines. Additional review is needed, but RWSA may request additional easements to allow a larger buffer between these critical water mains and the proposed new building units. 2. No street trees will be permitted within existing or proposed RWSA water easements. A list of permissible plantings in utility easements can be provided for review by request. Sheet No. 4: 1. Show and label the RWSA 30" water main (ductile iron), 24" water main (cast iron), and the 24" interconnection between the two mains. 2. Show the two RWSA water valves located at the interconnection. 3. Show and label the RWSA 12" water line (ductile iron) running parallel to Woodburn Road on TMP 45-68C2. 4. Show and label existing ACSA water service lines near the frontage of 45-68E on Woodburn Road. 5. See comment No. 1 on Sheet No. 3, above, regarding the potential need for additional easement. 6. There is extensive fill proposed along Berkmar Drive, which may impact the RWSA 24" and 30" water mains. Test pits may be required to determine the current depth of both water mains and whether this grading may negatively impact the RWSA water mains. 7. A minimum of 18" of vertical separation will be required at all utility crossings with the RWSA water mains. Test pits may be required to ensure adequate separation. 8. Per VDH Waterworks Regulations, all sanitary sewer lines that cross RWSA finished water mains shall be constructed of ductile iron pipe. Each pipe segment crossing the water mains shall be spaced evenly over the water main to maximize the distance between the water main and a sewer line joint. 9. Please show and call out all proposed water connections to RWSA mains. Please let me know if you have any questions. Thank you, Victoria Victoria Fort, P.E. Senior Civil Engineer Rivanna Water and Sewer Authority 695 Moores Creek Lane Charlottesville, VA 22902 (0): (434) 977-2970 ext. 205 (F): (434) 295-1146