DATE January 29, 1982
�= Katherine Imhoff , Pl r
P IJ
FROM: Fire Prevention Officer ;�`��
RE: Site Plan, Technical Review For EARLYSVII�LE FOREST
The below checked items apply to this site and are hereby recor,i.�ended to the
Commission:
� 1. Hydrants are required and must meet the followir_g requirements:
A. 2� C&O threads.
B. Located on highway right-of-way (when possible) .
C. No ci�ser than 50` or more than 400' to each major structure.
D. Every 800' along the roadway.
E. Every 500' around the perimeter of the building.
F, The fireflow requirement is gallons ger minute @ 20 PSI
(residual) .
X 2, A dry hydrant with adequate water from a pond is required. The surface
to the dry hydrant shall be accessable by use of an all weather compacteo
surface with a grade of not more thai� 20o and a turn-around space with a
radius of 90 feet the standpipe shall have a 4�" national standard
male fitting (see NFPA 1231) .
3. Dumpster location shall not be closer than 30' to any structure.
4. Handicapped provisions are required (see code of Virginia 35-124 & BOCA
Basic Building Code Article 316) .
X 5. Other comments and recommendations SEPARATION BETWEEN STRUCTURES
SHOULD NOT BE C7ASER THAN 100 FEET.
The attached plans do not show or incorrectly show:
Hydrant locations Handicapped facilities
Hydrant flow including curb cuts & ramps
Dumpster locations � Other
Mr_ S. Daley Craig - ZMA-81-11
April 20, 1981
Page four ,
D, Utilities; Fire Protection
. �* �* 1. Virqinia Department of Health approval of t��o (2} septic field locations
within each lot prior to Planninq Co�nission approval of any such lot.
Any lot not having adequate septic field location sha11 be combined with
a buildable lot and/or added to the cor.u::an open space. In addition,
- Homeowners' Association agreement shall include provision for use of oper
space far residential septic drainfields, if necessary;
� 2. All uses shall be served by one or_ more central water systems in
accordance with the regulations of the Virginia Department of Health,
the Co�e of Albemarle County, and all other applicable law. Water lines
and appurtenances shall be sized and desiqned in accordance with Albemar:
County 5ervice Authority specifica�ions for possible future acceptance;
�
��3. If a central well system is employed, Fire Official approval of aprurten�
. for future possible fire hydrant installations. Fire Official approval c:
appurtenances for future possible fire hydrant installations. Fire O��ic
approval of dry hydrant system orior to issuance of any certificate of oc
4. If a public water syste� is employed, Fire Official approvai of hy�rar.t
locations and fire flow prior to� �ssuance of any certificate of occupanc�
V5. A building separat�on of 100 fee_ shall b� maintai;�ed for dw�llzngs.
If you have any questions concerning tliis notification, please do not hesitate tc
contact this officeo