Loading...
HomeMy WebLinkAboutARB200400041 Plan - SubmittalO ti 11' -1 112" 7' -6 318° I rT-o I — -DLEINTEBNAI LY ILLUMINATED MONUMENT SIGN u so FT. ILLUMINATED (1) REQUIRED COLOR CHART VINYL CHART �1 M.A.P. SATIN FINISH WHITE V1 3M #3630.126 DARK EMERALD GREEN p� M.A.P. 47A -3P PLANTATION WHITE T�2 3M #3630 -97 BRISTOL BLUE SEGMENTED SUNBURST PEDIMENT FROM OUTWATER PRODUCTS ®1 FABRICATED ALUMINUM CABINET WITH HINGED FACE PAINTED M.A.P. SATIN FINISH WHITE P1 ROUTED .125" ALUMINUM FACE, ROUTED FOR PUSH - THROUGH COPY AND GRAPHICS: 'U', 'UNION ..TRUST, 24 HOUR BANKING, AND SCORE �OVERLAID WITH TRANSLUCENT GREEN VINYL V1 BLUE VINYL COPY AND GRAPHICS V2 APPLIED FIRST SURFACE P1 RICE AUG 10 2007 COMMUNITY DEVELOPNENl EXISTING CONDITIONS r . _ PHOTO SHOWS PROPOSED CHANNEL LETTERS. NOT TO SCALE. t0 I END VIEW I HAVE CAREFULLY REVIEWED AND HEREBY ACCEPT THE DRAWING(S) AS SHOWN. I REALIZE THAT ANY CHANGES TO THESE DESIGNS MADE BEFORE OR AFTER PRODUCTION MAY ALTER THE CONTRACT PRICE. ALL CHANGES MUST BE IN WRITING AND APPROVED BY BOTH PARTIES PRIOR TO PRODUCTION, SIGNATURE& DATE THE CUSTOM ARTWORK DEPICTED HEREIN IS 3 FOR REPRESENTATIONAL PURPOSES ONLY AND MAY NOT EXACTLY MATCH THE COLORS OF THE MATERIALS PROPOSED FOR USAGE. ELECTRIC SIGNS PRODUCED AT $ IMAGE WORKS CONFORM TO UL 48 e L STANDARDS AND DISPLAY THE UNDERWRITERS LABORATORIES LABEL. i ALL ONSITE PRIMARY ELECTRICAL CONNECTIONS BY OTHERS. u j DATE REVISION MCRIPTION DESIGNER � 7.26.07 ADD FOUNDATION WAM i n I c n 11046 LEADBETTER ROAD ASHLAND VIRGINIA 23005 PHONE 804.798.5533 FAX 804.798.5582 UNION SANK_. _ CLIENT CHARLOTTESVILLE, VA _.._. LOCATION IKEASHA_CHAPPELL SALE REPRESENTATIVE _WAM _ DESIGNER 7.16.07 _ DATE PREPARED SCALE UNION -BA- IVY -01 PROJECT ID M R1 DRAWING IDENTIFICATION �TNION SANK A RUST LETTERS MAY REQUIRED MODIFICATION TO ACCOMMODATE ILLUMINATION FACE -LIT INTERNALLY ILLUMINATED CHANNEL LETTERS 39 SQUARE FEET (1) SET REQUIRED LETTER CONSTRUCTION REQUIREMENTS FOR ELECTRICAL ILLUMINATION 2 AMP @ 120V BACKS:.040" WHITE / WHITE ALUMINUM PRIMARY ELECTRICAL LOCATION IS TO BE PROVIDED - VOLTAGE SHOULD READ NO MORE THAN (3) VOLTS BAFFLE: N/A BY OTHERS. A DEDICATED CIRCUIT WITH NO SHARED COLOR KEY RETURNS: 5" DEEP, .040 ALUMINUM, PMS #336C, SATIN FINISH NEUTRALS AND A GROUND RETURNING TO THE PANEL TRIM CAP: 1" GREEN IS REQUIRED FOR ALL INSTALLATIONS PMS #336C RETAINER: N/A SELF - CONTAINED: NO REQUIRED BY UL STANDARD #2161 AND IMAGE WORKS, REMOTE: YES ■ #2030 GREEN FLEX RACEWAY: N/A ALL TRANSFORMERS SHALL BE (GFI) GROUND FAULT INTERRUPTED TRANSFORMERS FACE DETAILS ALL SIGNS HAVE: PLEX: 3/16" TRANSLUCENT GREEN #2030 - DEDICATED BRANCH CIRCUITS LEXAN: N/A -THREE WIRES: LINE, NEUTRAL & GROUND FIRST SURFACE VINYLS: N/A -WIRE SIZE: MINIMUM 12 GAUGE THIN COPPER I ILLUMINATION ALSO NOTE; GAUGE OF COPPER IS DETERMINED BY THE LED: GREEN LENGTH OF RUN & AMPERAGE AS PER NEC ARTICLE 300. TRANSFORMERS: 60W - GROUND WIRE MUST BE CONTINUOUS AND GO FROM 2 AMP @ 120V THE SIGN TO THE PANEL BOARD GROUND BUS - VOLTAGE SHOULD READ NO MORE THAN (3) VOLTS WAM BETWEEN GROUND AND NEUTRAL - CONDUIT CAN NOT BE USED AS A GROUND PATH. EXISTING CONDITIONS r' Ii r PHOTO SHOWS PROPOSED CHANNEL LETTERS. NOT TO SCALE. ALUMINUM RETURNS #8 PANHEAD SCREW - 1" TRIMCAP 3/16" POP RIVET LED MODULES 1/2" EMT 6'ELECT #820 1/2" EMT COMPRESSION CONNECTOR PLEXIGLAS SIGN F, ALUMINUM BACK - 3/8" LAG BOLTS W/ SHIELDS AS REQUIRED 1/4" WEEP HOLES IN LOW SPOTS OF LETTERS, (2) EACH PER LETTER LED PO\ SUPPLY PFCL WITH LED ILLUMINATION, REMOTE POWER SUPPLY NOT TO SCALE I HAVE CAREFULLY REVIEWED AND HEREBY ACCEPT THE DRAWING(S) AS SHOWN. I REALIZE THAT ANY CHANGES TO THESE DESIGNS MADE BEFORE OR AFTER PRODUCTION MAY ALTER THE CONTRACT PRICE. ALL CHANGES MUST BE IN WRITING AND APPROVED BY BOTH PARTIES PRIOR TO PRODUCTION. SIGNATURE & DATE THE CUSTOM ARTWORK DEPICTED HEREIN IS FOR REPRESENTATIONAL PURPOSES ONLY AND MAY NOT EXACTLY MATCH THE COLORS OF THE MATERIALS PROPOSED FOR USAGE. ELECTRIC SIGNS PRODUCED AT IMAGE WORKS CONFORM TO UL 48 UL STANDARDS AND DISPLAY THE UNDERWRITERS LABORATORIES LABEL. ALL ONSITE PRIMARY ELECTRICAL CONNECTIONS BY OTHERS. DATE REVISION DESCRIPTION DESIGNER 11046 LEADBETTER ROAD ASHLAND VIRGINIA 23005 PHONE 804.798.5533 FAX 804.798.5582 UNION BANK Ile = I -u SCALE UNION -BA- IVY -01 PROJECT ID R2 DRAWING IDENTIFICATION CLIENT CHARLOTTESVILLE VA LOCATION KEASHA CHAPPELL SALE REPRESENTATIVE WAM DESIGNER 7.16.07 DATE PREPARED Ile = I -u SCALE UNION -BA- IVY -01 PROJECT ID R2 DRAWING IDENTIFICATION —T— o0 UNI ON BANK TRUST FLAT ALUMINUM PANEL 11 SQ. FT. .125" ALUMINUM PANEL, PAINTED WHITE, SATIN FINISH WITH FIRST SURFACE VINYLS 3M #3630 -126 DARK EMERALD GREEN (1) REQUIRED EXISTING CONDITIONS PHOTO SHOWS PROPOSED WALL SIGN. NOT TO SCALE. END VIEW MASORY ANCHORS AS REQ'D. I HAVE CAREFULLY REVIEWED AND HEREBY ACCEPT THE DRAWING(S) AS SHOWN. I REALIZETHATANY CHANGES TO THESE DESIGNS MADE BEFORE OR AFTER PRODUCTION MAY ALTER THE CONTRACT PRICE. ALL CHANGES MUST BE IN WRITING AND APPROVED BY BOTH PARTIES PRIOR TO PRODUCTION. SIGNATURE & DATE THE CUSTOM ARTWORK DEPICTED HEREIN IS FOR REPRESENTATIONAL PURPOSES ONLY AND MAY NOT EXACTLY MATCH THE COLORS OF THE MATERIALS PROPOSED FOR USAGE. ELECTRIC SIGNS PRODUCED AT U■ IMAGE WORKS CONFORM TO UL 48 o STANDARDS AND DISPLAYTHE UNDERWRITERS LABORATORIES LABEL. ALL ONSITE PRIMARY ELECTRICAL CONNECTIONS BY OTHERS. DATE REVISION DESCRIPTION DESIGNER 7.26.07 ADD PROD. SPEC. WAM 8.22.07 SIZE AND MORPH RLS 8.22.07 REVISE LIGHTING SPEC. WAM 11046 LEADBETTER ROAD ASHLAND VIRGINIA 23005 PHONE 804.798.5533 FAX 804.798.5582 UNION BANK DRAWING IDENTIFICATION CLIENT CHARLOTTESVILLE, VA LOCATION KEASHA CHAPPELL SALE REPRESENTATIVE WAM DESIGNER 7.16.07 DATE PREPARED 1" = 1' -0" SCALE UNION -BA- IVY -01 PROJECT ID DRAWING IDENTIFICATION -7 QI TCV i Q I r I NON - ILLUMINATED AWNING 2 SO. FT. COPY AREA AWNING FABRIC SUNBRELLA'ERIN GREEN' #4600, WITH 1' ALUMINUM AWNING FRAME. -COPY TO BE OPAQUE WHITE VINYL 3M 7725 -10 -MOUNT TO EXISTING MASORY (1) REQUIRED EXISTING CONDITIONS 1 2' -6 " PHOTO SHOWS PROPOSED AWNING. NOT TO SCALE, END VIEW I HAVE CAREFULLY REVIEWED AND HEREBY ACCEPT THE DRAWING(S) AS SHOWN, I REALIZE THAT ANY CHANGES TO THESE DESIGNS MADE BEFORE OR AFTER PRODUCTION MAY ALTER THE CONTRACT PRICE. ALL CHANGES MUST BE IN WRITING AND APPROVED BY BOTH PARTIES PRIOR TO PRODUCTION. 5fGNA7UPE &DATE THE CUSTOM ARTWORK DEPICTED HEREIN IS FOR REPRESENTATIONAL PURPOSES ONLY AND MAY NOT EXACTLY MATCH THE COLORS OF THE MATERIALS PROPOSED FOR USAGE. ELECTRIC SIGNS PRODUCED AT IMAGE WORKS CONFORM TO UL 48 STANDARDS AND DISPLAY THE UNDERWRITERS LABORATORIES LABEL ALL ONSITE PRIMARY ELECTRICAL CONNECTIONS BY OTHERS. DATE REVISION DESCRIPTION DESIGNER 11046 LEADBETTER ROAD ASHLAND VIRGINIA 23005 PHONE 804.798.5533 FAX 804,798.5582 UNION BANK ._ CLIENT CHARLOTTESVILLE. VA LOCATION _KEASHA CHAPPELL SALE REPRESENTATIVE DESIGNER DATE PREPARED 1 1/2" = f -0" SCALE UNION -BA- IVY -01 PROJECT ID DRAWING IDENTIFICATION .-�J �.-'� "'.i- t =�..- - _ .'s °: "�,xr.r�. _ _ - -_� .�. r-� •_'^_'P� •--.. �- ` ^tY�'R= ...^. -_'_ � .= _i.. +l'aT.1�,.YW'.�YY4Y116tV. z-- . -..s -. u_ l i 1 !} GQLor.l h1AJ�E A`�'aC?G� AST L-TO Tla �c I'" 1 A P [00 PA FeC.• f„ L 40C- - 2. / H C, 7-0 r J "C -4 PRC��'Ef2Y�f I�I�I✓ -.__. � _~ At�Jr7URltitflAUE / I � E.ASEME�IT. 6T, ANNEt> eE.LFIELD IWC- 0P,PO RAT 1 -0 l�� - -� _ - -- -_._ ,... FAX MAP 7 PARGI:�L 1 iv -- - ..___._.__ _._ _�_ --- R -1 z0N 1 hlG. AtvG >SGAP BUPf =E2 -- - -- - Z O x O Z t? O T f3AlZ8.0`6�A `T`¢L.�GT -rAx MAP 00 PAQ6EL, 4,0 E H.G - z- 0j tQc-j. ,Dl TE PLAN 5' 4LE; l`,=zc' i'� 19 ro� cam' / 9 ZIID Z�j / V� 12r -301 oil 0 1?-T H FLlTi�RE D,TM ,o �4 ONE- FLR-�...__ Fad t`I K I' H T, i `TH2LE I i l Li {U, E. 0'VE.I2H&Qej. - `� ql I LiGIH7 POLI<. x 12 GLISToME.R. Pl�fZKl>`1G � - _ 75 5.A.�- JIGIHWAY +fI _ � rrytt i 2 I G N T- O F -- \AMY. ..�V► -I I T k A .1 G� -�] 1 L• G. G?.i`!i P�1. k..1!r _ -r4&'G t— J &P-{AQ I-q,G. Z-DN! IJCG. I ftAA 9.� v 3j1 NOTE : THE CONTRACTOR SHALL CHECK ALL DIMENSIONS AND CON- DITIONS AT THE JOB.SITE AND REPORT ALL INCONSISTENCIES TO THE ARCHITE {.T 3 MARK DATE COMMENTS m rn m o. Q 0 m m z 3j1 NOTE : THE CONTRACTOR SHALL CHECK ALL DIMENSIONS AND CON- DITIONS AT THE JOB.SITE AND REPORT ALL INCONSISTENCIES TO THE ARCHITE {.T P-4 MARK DATE COMMENTS �(n 9 P-1 iii +• 7 CL ! . ! � / a r_a Z. .. .F n DETAIL NO LARGE SCALE r— SMALL SCA' E DETAIL ON INDICATION ON SHEET NO. SHEET NO. DETAIL REFERENCE SYSTEI1 NOTE : THE CONTRACTOR SHALL CHECK ALL DIMENSIONS AND CON- DITIONS AT THE JOB.SITE AND REPORT ALL INCONSISTENCIES TO THE ARCHITE {.T REVISIONS MARK DATE COMMENTS DATE -5 X01 e-)7 Joe � � I IBY SHEET