HomeMy WebLinkAboutARB200400041 Plan - SubmittalO
ti
11' -1 112"
7' -6 318°
I
rT-o I —
-DLEINTEBNAI LY ILLUMINATED MONUMENT SIGN u so FT.
ILLUMINATED
(1) REQUIRED
COLOR CHART VINYL CHART
�1 M.A.P. SATIN FINISH WHITE V1 3M #3630.126 DARK EMERALD GREEN
p� M.A.P. 47A -3P PLANTATION WHITE T�2 3M #3630 -97 BRISTOL BLUE
SEGMENTED SUNBURST PEDIMENT FROM
OUTWATER PRODUCTS ®1
FABRICATED ALUMINUM CABINET
WITH HINGED FACE PAINTED M.A.P.
SATIN FINISH WHITE P1
ROUTED .125" ALUMINUM FACE, ROUTED FOR
PUSH - THROUGH COPY AND GRAPHICS:
'U', 'UNION ..TRUST, 24 HOUR BANKING, AND SCORE
�OVERLAID WITH TRANSLUCENT GREEN VINYL V1
BLUE VINYL COPY AND GRAPHICS V2 APPLIED
FIRST SURFACE
P1
RICE
AUG 10 2007
COMMUNITY DEVELOPNENl
EXISTING CONDITIONS
r . _
PHOTO SHOWS PROPOSED CHANNEL LETTERS. NOT TO SCALE.
t0
I
END VIEW
I HAVE CAREFULLY REVIEWED AND HEREBY ACCEPT
THE DRAWING(S) AS SHOWN. I REALIZE THAT ANY
CHANGES TO THESE DESIGNS MADE BEFORE OR
AFTER PRODUCTION MAY ALTER THE CONTRACT
PRICE. ALL CHANGES MUST BE IN WRITING AND
APPROVED BY BOTH PARTIES PRIOR TO PRODUCTION,
SIGNATURE& DATE
THE CUSTOM ARTWORK DEPICTED HEREIN IS
3 FOR REPRESENTATIONAL PURPOSES ONLY
AND MAY NOT EXACTLY MATCH THE COLORS
OF THE MATERIALS PROPOSED FOR USAGE.
ELECTRIC SIGNS PRODUCED AT
$ IMAGE WORKS CONFORM TO UL 48
e L STANDARDS AND DISPLAY THE
UNDERWRITERS LABORATORIES LABEL.
i
ALL ONSITE PRIMARY ELECTRICAL CONNECTIONS BY OTHERS.
u
j DATE REVISION MCRIPTION DESIGNER
� 7.26.07 ADD FOUNDATION WAM
i
n
I
c
n
11046 LEADBETTER ROAD ASHLAND VIRGINIA 23005
PHONE 804.798.5533 FAX 804.798.5582
UNION SANK_.
_
CLIENT
CHARLOTTESVILLE, VA
_.._.
LOCATION
IKEASHA_CHAPPELL
SALE REPRESENTATIVE
_WAM _
DESIGNER
7.16.07
_
DATE PREPARED
SCALE
UNION -BA- IVY -01
PROJECT ID
M R1
DRAWING IDENTIFICATION
�TNION SANK
A RUST
LETTERS MAY REQUIRED MODIFICATION
TO ACCOMMODATE ILLUMINATION
FACE -LIT INTERNALLY
ILLUMINATED CHANNEL LETTERS
39 SQUARE FEET
(1) SET REQUIRED
LETTER CONSTRUCTION
REQUIREMENTS FOR ELECTRICAL ILLUMINATION
2 AMP @ 120V
BACKS:.040" WHITE / WHITE ALUMINUM
PRIMARY ELECTRICAL LOCATION IS TO BE PROVIDED
- VOLTAGE SHOULD READ NO MORE THAN (3) VOLTS
BAFFLE: N/A
BY OTHERS. A DEDICATED CIRCUIT WITH NO SHARED
COLOR KEY
RETURNS: 5" DEEP, .040 ALUMINUM, PMS #336C, SATIN FINISH
NEUTRALS AND A GROUND RETURNING TO THE PANEL
TRIM CAP: 1" GREEN
IS REQUIRED FOR ALL INSTALLATIONS
PMS #336C
RETAINER: N/A
SELF - CONTAINED: NO
REQUIRED BY UL STANDARD #2161 AND IMAGE WORKS,
REMOTE: YES
■ #2030 GREEN FLEX RACEWAY: N/A
ALL TRANSFORMERS SHALL BE (GFI) GROUND
FAULT INTERRUPTED TRANSFORMERS
FACE DETAILS
ALL SIGNS HAVE:
PLEX: 3/16" TRANSLUCENT GREEN #2030
- DEDICATED BRANCH CIRCUITS
LEXAN: N/A
-THREE WIRES: LINE, NEUTRAL & GROUND
FIRST SURFACE VINYLS: N/A
-WIRE SIZE: MINIMUM 12 GAUGE THIN COPPER
I
ILLUMINATION
ALSO NOTE; GAUGE OF COPPER IS DETERMINED BY THE
LED: GREEN
LENGTH OF RUN & AMPERAGE AS PER NEC ARTICLE 300.
TRANSFORMERS: 60W
- GROUND WIRE MUST BE CONTINUOUS AND GO FROM
2 AMP @ 120V
THE SIGN TO THE PANEL BOARD GROUND BUS
- VOLTAGE SHOULD READ NO MORE THAN (3) VOLTS
WAM
BETWEEN GROUND AND NEUTRAL
- CONDUIT CAN NOT BE USED AS A GROUND PATH.
EXISTING CONDITIONS
r' Ii r
PHOTO SHOWS PROPOSED CHANNEL LETTERS. NOT TO SCALE.
ALUMINUM RETURNS
#8 PANHEAD SCREW -
1" TRIMCAP
3/16" POP RIVET
LED MODULES
1/2" EMT
6'ELECT
#820 1/2" EMT COMPRESSION
CONNECTOR
PLEXIGLAS SIGN F,
ALUMINUM BACK -
3/8" LAG BOLTS W/ SHIELDS
AS REQUIRED
1/4" WEEP HOLES IN LOW SPOTS
OF LETTERS, (2) EACH PER LETTER
LED PO\
SUPPLY
PFCL WITH LED ILLUMINATION, REMOTE POWER SUPPLY
NOT TO SCALE
I HAVE CAREFULLY REVIEWED AND HEREBY ACCEPT
THE DRAWING(S) AS SHOWN. I REALIZE THAT ANY
CHANGES TO THESE DESIGNS MADE BEFORE OR
AFTER PRODUCTION MAY ALTER THE CONTRACT
PRICE. ALL CHANGES MUST BE IN WRITING AND
APPROVED BY BOTH PARTIES PRIOR TO PRODUCTION.
SIGNATURE & DATE
THE CUSTOM ARTWORK DEPICTED HEREIN IS
FOR REPRESENTATIONAL PURPOSES ONLY
AND MAY NOT EXACTLY MATCH THE COLORS
OF THE MATERIALS PROPOSED FOR USAGE.
ELECTRIC SIGNS PRODUCED AT
IMAGE WORKS CONFORM TO UL 48
UL STANDARDS AND DISPLAY THE
UNDERWRITERS LABORATORIES LABEL.
ALL ONSITE PRIMARY ELECTRICAL CONNECTIONS BY OTHERS.
DATE REVISION DESCRIPTION DESIGNER
11046 LEADBETTER ROAD ASHLAND VIRGINIA 23005
PHONE 804.798.5533 FAX 804.798.5582
UNION BANK
Ile = I -u
SCALE
UNION -BA- IVY -01
PROJECT ID
R2
DRAWING IDENTIFICATION
CLIENT
CHARLOTTESVILLE VA
LOCATION
KEASHA CHAPPELL
SALE REPRESENTATIVE
WAM
DESIGNER
7.16.07
DATE PREPARED
Ile = I -u
SCALE
UNION -BA- IVY -01
PROJECT ID
R2
DRAWING IDENTIFICATION
—T—
o0
UNI
ON
BANK
TRUST
FLAT ALUMINUM PANEL 11 SQ. FT.
.125" ALUMINUM PANEL, PAINTED WHITE, SATIN FINISH
WITH FIRST SURFACE VINYLS 3M #3630 -126 DARK EMERALD GREEN
(1) REQUIRED
EXISTING CONDITIONS
PHOTO SHOWS PROPOSED WALL SIGN. NOT TO SCALE.
END VIEW
MASORY ANCHORS
AS REQ'D.
I HAVE CAREFULLY REVIEWED AND HEREBY ACCEPT
THE DRAWING(S) AS SHOWN. I REALIZETHATANY
CHANGES TO THESE DESIGNS MADE BEFORE OR
AFTER PRODUCTION MAY ALTER THE CONTRACT
PRICE. ALL CHANGES MUST BE IN WRITING AND
APPROVED BY BOTH PARTIES PRIOR TO PRODUCTION.
SIGNATURE & DATE
THE CUSTOM ARTWORK DEPICTED HEREIN IS
FOR REPRESENTATIONAL PURPOSES ONLY
AND MAY NOT EXACTLY MATCH THE COLORS
OF THE MATERIALS PROPOSED FOR USAGE.
ELECTRIC SIGNS PRODUCED AT
U■ IMAGE WORKS CONFORM TO UL 48
o STANDARDS AND DISPLAYTHE
UNDERWRITERS LABORATORIES LABEL.
ALL ONSITE PRIMARY ELECTRICAL CONNECTIONS BY OTHERS.
DATE REVISION DESCRIPTION DESIGNER
7.26.07 ADD PROD. SPEC. WAM
8.22.07 SIZE AND MORPH RLS
8.22.07 REVISE LIGHTING SPEC. WAM
11046 LEADBETTER ROAD ASHLAND VIRGINIA 23005
PHONE 804.798.5533 FAX 804.798.5582
UNION BANK
DRAWING IDENTIFICATION
CLIENT
CHARLOTTESVILLE, VA
LOCATION
KEASHA CHAPPELL
SALE REPRESENTATIVE
WAM
DESIGNER
7.16.07
DATE PREPARED
1" = 1' -0"
SCALE
UNION -BA- IVY -01
PROJECT ID
DRAWING IDENTIFICATION
-7
QI TCV
i
Q I
r I
NON - ILLUMINATED AWNING 2 SO. FT. COPY AREA
AWNING FABRIC SUNBRELLA'ERIN GREEN' #4600, WITH
1' ALUMINUM AWNING FRAME.
-COPY TO BE OPAQUE WHITE VINYL 3M 7725 -10
-MOUNT TO EXISTING MASORY
(1) REQUIRED
EXISTING CONDITIONS
1 2' -6 "
PHOTO SHOWS PROPOSED AWNING. NOT TO SCALE,
END VIEW
I HAVE CAREFULLY REVIEWED AND HEREBY ACCEPT
THE DRAWING(S) AS SHOWN, I REALIZE THAT ANY
CHANGES TO THESE DESIGNS MADE BEFORE OR
AFTER PRODUCTION MAY ALTER THE CONTRACT
PRICE. ALL CHANGES MUST BE IN WRITING AND
APPROVED BY BOTH PARTIES PRIOR TO PRODUCTION.
5fGNA7UPE &DATE
THE CUSTOM ARTWORK DEPICTED HEREIN IS
FOR REPRESENTATIONAL PURPOSES ONLY
AND MAY NOT EXACTLY MATCH THE COLORS
OF THE MATERIALS PROPOSED FOR USAGE.
ELECTRIC SIGNS PRODUCED AT
IMAGE WORKS CONFORM TO UL 48
STANDARDS AND DISPLAY THE
UNDERWRITERS LABORATORIES LABEL
ALL ONSITE PRIMARY ELECTRICAL CONNECTIONS BY OTHERS.
DATE REVISION DESCRIPTION DESIGNER
11046 LEADBETTER ROAD ASHLAND VIRGINIA 23005
PHONE 804.798.5533 FAX 804,798.5582
UNION BANK ._
CLIENT
CHARLOTTESVILLE. VA
LOCATION
_KEASHA CHAPPELL
SALE REPRESENTATIVE
DESIGNER
DATE PREPARED
1 1/2" = f -0"
SCALE
UNION -BA- IVY -01
PROJECT ID
DRAWING IDENTIFICATION
.-�J �.-'� "'.i- t =�..- - _ .'s °: "�,xr.r�. _ _ - -_� .�. r-� •_'^_'P� •--.. �- ` ^tY�'R= ...^. -_'_ � .= _i.. +l'aT.1�,.YW'.�YY4Y116tV. z-- . -..s -. u_
l
i
1
!} GQLor.l h1AJ�E A`�'aC?G� AST L-TO
Tla �c I'" 1 A P [00 PA FeC.• f„ L 40C- - 2.
/ H C, 7-0 r J "C -4
PRC��'Ef2Y�f I�I�I✓ -.__. � _~ At�Jr7URltitflAUE / I
� E.ASEME�IT.
6T, ANNEt> eE.LFIELD IWC- 0P,PO RAT 1 -0 l�� - -� _ - -- -_._ ,...
FAX MAP 7 PARGI:�L 1 iv -- - ..___._.__ _._ _�_ ---
R -1 z0N 1 hlG.
AtvG >SGAP BUPf =E2 -- - -- -
Z
O
x
O
Z
t?
O
T
f3AlZ8.0`6�A `T`¢L.�GT
-rAx MAP 00 PAQ6EL, 4,0 E
H.G - z- 0j tQc-j.
,Dl TE PLAN
5' 4LE; l`,=zc'
i'�
19
ro�
cam' /
9
ZIID
Z�j /
V�
12r
-301 oil
0 1?-T H
FLlTi�RE D,TM
,o
�4
ONE- FLR-�...__
Fad t`I K I' H T,
i
`TH2LE
I
i l
Li {U, E.
0'VE.I2H&Qej.
-
`�
ql I
LiGIH7 POLI<. x
12 GLISToME.R. Pl�fZKl>`1G �
- _ 75 5.A.�- JIGIHWAY
+fI _ � rrytt
i
2 I G N T- O F -- \AMY.
..�V► -I I T k A .1 G� -�] 1 L• G. G?.i`!i P�1. k..1!r _
-r4&'G t— J &P-{AQ
I-q,G. Z-DN! IJCG.
I ftAA
9.�
v
3j1
NOTE : THE CONTRACTOR SHALL
CHECK ALL DIMENSIONS AND CON-
DITIONS AT THE JOB.SITE AND REPORT
ALL INCONSISTENCIES TO THE ARCHITE {.T
3
MARK
DATE
COMMENTS
m
rn
m
o.
Q
0
m
m
z
3j1
NOTE : THE CONTRACTOR SHALL
CHECK ALL DIMENSIONS AND CON-
DITIONS AT THE JOB.SITE AND REPORT
ALL INCONSISTENCIES TO THE ARCHITE {.T
P-4
MARK
DATE
COMMENTS
�(n
9
P-1
iii +•
7
CL
! . ! � / a r_a Z. .. .F n
DETAIL NO
LARGE SCALE r— SMALL SCA' E
DETAIL ON INDICATION ON
SHEET NO. SHEET NO.
DETAIL REFERENCE SYSTEI1
NOTE : THE CONTRACTOR SHALL
CHECK ALL DIMENSIONS AND CON-
DITIONS AT THE JOB.SITE AND REPORT
ALL INCONSISTENCIES TO THE ARCHITE {.T
REVISIONS
MARK
DATE
COMMENTS
DATE
-5 X01 e-)7
Joe �
� I
IBY
SHEET