HomeMy WebLinkAboutSDP202000052 Plan - Submittal (First) 2021-07-14PRELIMINARY CENTRAL SEWAGE SYSTEM PLAN FOR: REGENTS SCHOOL OF CHARLOTTESVILLE S D P2020-010 LEGEND TAX MAP 75, PARCEL 66 EXISTING NEW DESCRIPTION TAX MAP 76, PARCEL 17 BOUNDARIES 011111110 BENCHMARK ALBEMARLE COUNTY, VIRGINIA SITE PROPERTY LINE ADJACENT PROPERTY LINE VICINITY MAPSCALE : , =1000' BUILDING SETBACK PARKING SETBACK SITE TEXT OWN ER/DEVELOPER 10 10 PARKING COUNT Regents School of Charlottesville Inc. TOPOGRAPHY 3045 Ivy Road B U C K I N G H A M INDEX CONTOUR Charlottesville, Virginia 22903 �' BALM 0 R A L INTERVAL CONTOUR PLAN PREPARATION HEIGHT S RESERVOIR ROAD 311.5 x �� SPOT ELEVATION Shimp Engineering, P.C. Umversdy Q Montesson School 311.5 TC x TOP OF CURB ELEVATION 912 East High Street Charlottesville, VA 22902 Charlottesville, ,SITE Fontaine Research Park Q 311.5 TW x TOP OF WALL ELEVATION (434) 227-5140 m� Rugged Mountain Q my Presoytenan 311.5 BW x �— BOTTOM OF WALL ELEVATION ZONING Hnmr+tl I �urch — STREAM EC - Entrance Corridor STREAM BUFFER R1 - Residential SP201800011 approved on September 18, 2019 andr..rre•bra 0 100 YEAR FLOODPLAIN permitting a private school use on the site n BUILDING MAGISTERIAL DISTRICT BUILDING Samuel Miller RETAINING WALL SOURCE OF TITLE STAIRS EDGE OF PAVEMENT DB 5237 P 251 DB 660 P 780 (plat) IMAGE PROVIDED BY GOOGLE MAPS ROAD CENTERLINE EXISTING USE FRONT OF CURB Vacant Land BACK OF CURB PROPOSED USE CG-12 TRUNCATED DOME SIDEWALK Private School (Grades K-12) 468 Students BIKE PARKING NOTES HANDICAP ACCESSIBLE AISLE Regents School site plan improvements shown for reference only. HANDICAP PARKING This plan only proposes the new sanitary sewer system to serve MATERIAL Regents School. SHIMP CONCRETE RELIABILITY CLASSIFICATION RIPRAP Class ENGINEERING2. ASPHALT LAND PLANNING -PROJECT MANAGEMENT EC-2 MATTING EC-3 MATTING SHEET INDEX 912 E. HIGH ST. 434.227.5140 WETLAND CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM TREELINE C1 COVER X X FENCE C2 SITE OVERVIEW UTILITY C3 SANITARY SEWER FORCE MAIN PLAN UTILITY POLE m m GUY WIRE C4 SANITARY SEWER GRAVITY FLOW PLAN OHU OHU OVERHEAD UTILITY CS SANITARY SEWER PUMP STATION DETAILS ucu —ucu — UNDERGROUND UTILITY C6 SANITARY SEWER PUMP STATION CALCULATIONS p STORM v JLJ TUN S Y Lie. N . 45183 STORM MANHOLE 113 2 1 w4 q q DROP INLET �0 STORM SEWER G `S IONAL E� ROOF DRAIN SANITARY SANITARY MANHOLE SANITARY SEWER MAIN CENTRAL SEWAGE SYSTEM PLAN S S SANITARY SEWER LATERAL REGENTS WATER W W WATER LINE SCHOOL O O WATER METER 0 o WATER METER VAULT 111"M FIRE HYDRANT ALBEMARLE COUNTY, VIRGINIA A A FIRE DEPARTMENT CONNECTION SUBMISSION: GAS 2021.07.12 GAS GAS — GAS LINE REVISION: EASEMENTS CONSTRUCTION GRADING ACCESS SIGHT DISTANCE UTILITY STORMWATER FACILITY MAINTENANCE STORMWATER ACCESS FILE NO. DRAINAGE 18.020 SANITARY WATERLINE GASLINE COVER NOTE: 1. THE SIZE OF THE SYMBOLS MAY VARY FROM WHAT IS SHOWN. C1 / / / NH / DAVID HARLOW 6/ D.B. 290, PG . 154 / TM 75-61 \ / ZONE: R1 RESIDENTIA/ / USE: SINGLE FAMILY R SI NTIAL \ N/ / RICHARD SHRUM / D.B. TM 7 , PG. 60 194 / USE: SINGLEEN RFAMILRESYDRESIDENTIAL r� N / TON DI DINH D B 4415, PG. 7 TM 75-61A ZONE R1 RESIDENTIAL USE: SINGLE FAMILY RESIDENTIAL � >7 O \ Cy \ 222 52':. N4^ N 47 09,—_�7___ REGENTS SCHOOL OF CHARLOTTESVILLE INC m� D.B. 5237, PG. 251 / i? TM 75-66 / T O O I I1 1 I 1 1 I I 1 I 1 1 1 N/F I N/F 1 CECL JOHNSON UNIVERSITY OF VIRGINIA FOUNDATION I D.B. 936, PG. 722 1 TM 76-14 1 D.B. 4170, PG. 689 ZONE: R1 RESIDENTIAL I TM 76-13B 1 USE: SINGLE FAMILY RESIDENTIAL ZONE: R1 RESIDENTIAL USE: SINGLE FAMILY RESIDENTIAL 45.02'44" E 264.31' REGENTS SCHOOL OF CHARLOTTESVILLE INC D,B. 5237, PG. 251 TM 76-17 Z/S \ REGENTS SCHOOL SITE NEW 60" DIA. PUMP STATION TO SERVE REGENTS SCHOOL ......... — r w wow w w w M �w } �._ 322 p��.�m�$ O 1 E X, k7-0 ate$ 4 k w°srai�iw 4 ` k � S � NEW 3)1 FORCE MAIN TO ACSA SANITARY SEWER SYSTEM TRINITY PRESBYTERIAN CHURCH t:. GraphicScale:•0 NEW ACSA MANHOLE NEW GRAVITY SEWER 38 LF EXISTING ACSA SANITARY SEWER SYSTEM 240 SHIMP ENGINEERING LAND PLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM U Lie. N . 45183 � 12 k 4� � OX72TT. E01. � 1 CENTRAL SEWAGE SYSTEM PLAN REGENTS SCHOOL ALBEMARLE COUNTY, VIRGINIA SUBMISSION: 2021.07.12 REVISION: FILE NO. CENTRAL SEWER OVERVIEW 18.020 C21 20 dry. \�\ _% C� 30 0 30 60 90 o Graphic Scale: 1 "=30' 00 \ \ w w —w�� �w �w �w —w —w {— 2 w —wI—w —w '8Xo _ -- _-\ \ -_ - — i. ° — \\\9.7 �00 61 CG-6 NOT T�1 �. —.. —.. —.. _ — — NEW 2 �_T SA EXCEED i SLOPE — — — — \ — �i i-N, \ \ AT6G�12 3 SVC — — \ % — i i 17+00 6�\\ \ L7F \11A�'00 �L� _ raa . ^ a; — — T — . �..0 ..,, / i75+ 5/8' WM / — — _��w CW 0� lV IN / W \ SF \ — — C ON','SRO• ASSR�OM ETAINING WALL M%> EIGHT 6' \ \ \ — "� 2,�86 S� _ 2,255 SF / F 5X00 8. 514.� / \ — ADMINISTRATIVE \ &EGEI9TS — / BUILDING L/ HALL -F-E 518 E3T8:5� .5-- — 606 F — — �/,�_ \ \ \ \ \ \ \ \ \ — — — _ — — — — — / // i _F_'!_ \ .,�.``• // \ \� O. \\ \ \ \ CLASS 0 \ ^ /FFE 5 r — — —FE IS ^\ / CL sSF- ME SR0,01 -- ` — — — — — — — — 5,74.5 m /CI N--CL-6A0 S0 SBOOM ` o 'EOM OFFS / \ \\ \ _ — — — \ \ \ \�_" \/ \ /\ ✓/__'_/—\ I �7II�I\� _—_ _— -- �GV0P� 51Ooy. 5E5RsF ��5 //FF_ `/ /I// I //\///IIS// ,la `'I r/ / /// — / / �--\\� \�\ \\�\ \_ \\ _Y\'—\� \— —�—\ -- — --- -----_ _-- ------ -- --� -- _ —`_\— —�\_ \ / —�\\ I — — \ \ \ \\�7` / l\ 1\ \ `\// 1II/ I �I // �/ FFE 514.5 00I N/ EVl /10F IVAT S�ANAR-0ROD-OOM 6 DIAMETER z SE FFE 514.5 k5 MP STATIOiV IiASEM�T 0Z / 7 9Q/A2Op// . nI / BUILDING 4, / / / — — _ \ \ \ � / / / / / I I I / I I I cR \ \ I ,ELEVATED ON PIER // / / / / / / ,— — _ — \ — \ — — — \ ` \ I\ \) / /I / / / / / / / / // / / / 11 l I I I I (A \� F FOUNBATIONS \ NEW 247 LF - 8,, SDR- 8 — / / / / / / / / / / `" \ — — — - / / / / / / \\----------_\ _ — \ _ / / / / --pQe- I / I L �\ �4 °, P� LO 0 � 00 N C� 240----/ PH Cl- CD CD \ \ \ 8' WL 40pp-� \� W _ W\ 23+ 00 �,. T.X: LINE' \ \ ) I Lf) I I /�� / -PL C� X' T� R wl I ROUTE 2 24t50 W zc— \ \ EPLA E q E LINE WITH�ALLEL INSi�iL ? W _ _ � 70 - RES �'— )9 I � w W 10 0p - ERVO -ROAD ) . 25+00� F ) / / CUT & CAP EX. 6 LINE / \ 26+00 \ 2+00 27+25 F �` UPON eOWLETfORT \ .. .. \.. . F - NEi4-8" N� F a \ .. w —w ,f SHIMP ENGINEERING LAND PLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM U Lie. N . 45183 � i2 � IOX72T. E� CENTRAL SEWAGE SYSTEM PLAN REGENTS SCHOOL ALBEMARLE COUNTY, VIRGINIA SUBMISSION: 2021.07.12 REVISION: FILE NO. 18.020 SANITARY SEWER FORCE MAIN PLAN C3 BACKUP RENERATXR .1. WATER AI SLEV. - 185.31' LAC ROW'N' El£V. A9A.21 I D PUMP 'ORT ELEV. A93.2L— ALL PIMPS'OR" ELEV. ABR.A7— .. OF MET.1 ELEV. ABB.Ctl CONTROL PANEL BOY. SHALL CONTAIN A REMOTE MONITORING SYBTEY TO BE MANAGED BY A CONTRACTED PRCTESSIoNAL THIRD PARTY. �MICN WATER AXSL uCAIT CCH1R(IL PANEL IMET .1 - ABBS9' S' TOP VIEW CCMCBm PAD BAIXUP WIERARM BM"'l PANEL O FRONT VIEW SIDE VIEW SANITARY SEWER PUMP STATION DETAILS Scale: 1 CONTRACTOR SHALL OBTAIN SHOP DRAWINGS FROM VENDOR FOR PUMP ASSEMBLY, GENERATOR, AND CONTROL PANELS. SUBMIT SHOP DRAWINGS TO ENGINEER FOR REVIEW OF ANY PROPOSED CHANGES AND FINAL APPROVAL OF DRAWINGS PRIOR TO PURCHASE OF PUMP -RELATED EQUIPMENT. (B-WAY) TRACED MP£ INSTALLED ALONG OISMARCIS TINE DISCNARIE TINE SHIMP ENGINEERIN 32 LAND PLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM U Lie. N . 45183 h ilk 4� kpp CENTRAL SEWAGE SYSTEM PLAN REGENTS SCHOOL ALBEMARLE COUNTY, VIRGINIA SUBMISSION: 2021.07.12 REVISION: FILE NO. 18.020 SANITARY SEWER 30 0 30 60 90 PUMP STATION DETAILS Graphic Scale: Hcrx: 1"-30' Vert: 1 "=10 C5 APPLICATION DATAAND CONSTRUCTION DETAILS Maximum Solid Size 3" Minimum Casing Thickness 516" Casing Corrosion Allowance W. Maximum Working Pressure 30 PSI Maximum Submergence 50 feet Minimum Submergence Fully submerged for continuous operation 6" below top of motor for intermittent operation Maximum Environmental Temperature 400 C(104° F) continuous operation, 60°C(140" F) intermittent operation Power Cable -Type (See Motor Information forAWG data/size.) Type SJTOW: single phase, 1 6 and 2 HP Type STOW: single phase, 1'k - 3 HP and 5 HP, 460 V Type STOW: single phase, 3 and 5 HP, three phase 5 HP, 230 V and 71h HP Motor Cover, Bearing Housing, Seal Housing, Casing Gray Cast Iron -ASTM A48, Class 30 Impeller - Standard, Optional Gray Cast Iron -ASTM A48 or Cast Bronze - ASTM B584 C87600 Motor Shaft AISI 300 Series Stainless Steel Motor Design NEMA 56 Frame, oil filled with Class F Insulation Motor Overload Protection Singlephase: on winding thermal overload protection auto reset Threephase: requires Class 10 overloads in control panel External Hardware 300 Series Stainless Steel Im ellerT a Semi -open with pump out vanes on back shroud Oil Capacity- Seal Chamber 1.5 quarts Oil Capacity - Motor Chamber life-5 HP single and threephase: 7 quarts 7%HP three phase: 6.5 quarts Mechanical Seals - Standard PUpper I Carbon/Ceramic; Type 21 Lower I Silicon Carbide/Silicon Carbide; Type 31 Mechanical Seals - Optional Lower I Silicon Carbiderrungsten Carbide; Type 31 (All dimensions are in inches. Do not use for construction purposes.) 25 a it FLAN E 3.50" APPLICATIONS Used in a variety of residential, commercial and industrial applications such as: • Sewage systems, Flood and Pollution Control, Dewatering/Effluent, Farms, Hospitals, Trailer Courts, Motels SPECIFICATIONS Pump: • Maximum solid size: 3" • Discharge size: 4 , 125 # ANSI flange • Maximum capacity: 620 GPM • Maximum total head: 60 feet • 300 Series stainess steel fasteners • 20' Power cord • Standard silicon carbide/silicon carbide outer seal Motor: • Maximum ambient temperature: 1040 F (40' C) continuous duty, 140' F (60' C) intermittent duty • Rated for continuous duty when fully submerged • Insulation: Class F e 60 Hertz • Single row ball bearings • 300 Series stainless steel keyed shaft Single Phase: • 1.5 - 5 HP; 208 and 230 volts e Built-in thermal overloads with automatic reset e Built-in capacitors MODELAND MOTOR Throe Phase: • 1.5 - 7.5 HP; 200, 230,460 and 575 volts • Class 10 overload protection must be provided in control panel MOTORS • Fully submerged in oil -filled chamber: High grade turbine oil surrounds motor for more efficient heat dissipation, permanent lubrication of bearings and mechanical seal for complete protection against outside environment. • Class F insulation • Designed for Continuous Operation: Pump ratings are within the motor manufacturer's recommended working limits and can be operated continuously without damage when fully submerged. • Bearings: Upper and lower heavy duty ball bearing construction for precision positioning of parts and to carry thrust loads. • Power Cable: Severe duty rated, oil and water resistant. Epoxy seal on motor end provides secondary moisture barrier in case of outer jacket damage and to prevent oil wicking. 20 foot standard with optional lengths available. • O-ring: Assures positive sealing against contaminants and oil leakage. AGENCY LISTINGS c Tested to UL 778 and CSA 22.2 108 Standards By Canadian Standards Association File #LR38549 Order No. NP Phase Voth RPM Impeller Dia. in. Maximum Am LB. Am KVA Code Power Cable F.L. Resistance Wt. (lbs.) Start Line -Line WS1518D4M W51512D4M 1.5 1 208 1750 5.63 17.2 50.8 B 14/31.4 1.1 0.9 195 230 14.7 29.5 E 1.8 WS1538D4M W51532D4M 3 200 11.5 40.9 H 14/4NA 1.7 230 10.0 40.0 F P.3 W 15 4D4M WS1537D4M 46 5.0 20.0 F 9.3 575 4.0 14.4 H 14.8 WS1518D4 WS1512D4 W51538D4 WS1532D4 1.5 1 208 1750 6.25 17.2 50.8 B 14/31.4 1.1 0.9 195 230 14.7 29.5 E 1.8 3 200 11.5 40.9 H 14/4 81 MP' 1.7 230 10.0 40.0 F 83 2.3 W 15 4D4 WS1537D4 46 5.0 20.0 F 8 9.3 575 4.0 14.4 H 74 14.8 WS2018D4 WS2012D4 WS2038D4 W52032D4 WS203404 2 1 208 1750 6.63 20.3 50.8 B 14/31.4 1.1 0.9 200 230 17.3 36.9 D 1.5 3 200 13.3 40.9 H 14/4NA9.3 1.7 230 11.6 40.0 F 2.3 460 5.8 20.0 F W52037D4 575 4.6 14.4 H 14.8 W53018D4 W53038D4 WS3032D4 3 208 ;1750.' 7.00 25.5 50.8 B �C; f10%3.�1.01 M85 1.1 0.9WS3012D4i ;2301 ;215' '46.41 1.0'208 3 20016.6 53.8 G 10/4 1.3 230 14.4 49.5 H 14/4NA 1.9 WS3034D4 WS3037D4 7.2 24.8 H 75205 5.8 17.3 G 11.6 WS5012D4 WS5038D4 5 1 7.25 26.5 57.7 A 10/3 80 1.0 0.8 213 350 19.1 73.9 F 10/4NA 84 0.9 210WS5037D4 t 14/480 6.6 22.8 E 7.4 W57532D4 W57534D4 7.5 3 50 7.69 23.0 105.0 G 10/4 83 NA 0.7 225 11.5 52.5 G 83 2.8 WS7537D4 9.2 42.0 E 84 4.4 PAGE 2 PUMP SPECIFICATIONS C6 Scale: N/A Discharge Pipe Information Pipe 1 3" force main Pipe 1 Pipe length (feet) 1500 ft Pipe diameter (inches) 3 in Pipe C-factor 120 Portion of Flow 1 Cross -sectional area (feet) 0.049 ft Hydraulic radius 0.063 ft Suction water surface elevation (A) Suction water surface elevation (B) Discharge water surface elevation Static head (A) Static head (B) 488.00 feet 489.00 feet 490.00 feet 2.0 feet 1.0 feet Daily Average Flowrates Type: Unit: Number of Units: gpcVunk Total(gpd) Grade School w/ Showers per student / staff 468 16 7,488 F I I I I `day assumed to be 12-hrfor purpose of this analysis. Total 7,488 Daily Peak Flowrates Type: Un it: Number of Units: Daily Average Flow gpd (12-hr) 7,486 Daily Average Flow gpm 10.40 Peaking Factor n/a 2.5 Peak Daily Flow gpm 26.01 Wet Well Sizing Type: Lin it: Number of Units: Diameter ft 5 Volume per foot gallons 100 Wet Working Depth ft 5.24 Wet Working Volume gallons 5.95 Total Storage gallons 1,422 Pumping Rate gpm 75 Time to Empy minutes 19 Duplex Rump (2 Pumps) I Parameter Ftessure Ppe Length, (ft) Rpe Dia., (in) HazenWllliam;Gbeff. C 1500 3 120 "Piping from purrp basin to discharge point Minor Losses Typg Kvalues # Fittings Cate Valve 0.19 0 Rua Valve a/oo 0.86 1 Butterfly Valve 0.4 0 SeAng Check Valve 2.5 1 W Bend 0.25 1 45' Bend 0.2 3 22.50 Bend 0.12 0 11.25' Bend 0.06 0 Tee (through) 0.6 0 Tee side out 1.8 0 QoSs hrcu h 0.6 0 QnSs Iside cut 1.8 0 Heduoerf Increaser 0.1 0 Discharcietoar 1 1 120.00 100.00 80.00 x = 60.00 0 40.00 20.00 System Curve - Head Loss Calculations Flowrake Water Velocity In: Dynamic Losses, It Total Dynamic Head Total Dynamic Head (+20%) gpm cfs Velocity ft/s Minor Losses Pipe Friction Max. Lift ft Min. Lift fk Max. Lift ft Min. Lift ft 0 0 0 0 0 2.00 1.00 2.40 1.20 5 0.01 0.23 0.00 0.21 2.21 1.21 2.66 1.46 10 0.02 0.45 0.01 0.75 2-77 1.77 3.32 2.12 15 0.03 0.68 0.03 1.60 3.63 2.63 4.35 3.15 20 0.04 0.91 0.06 2.72 4.78 3.70 5.73 4.53 25 0.06 1.13 0.09 4.11 6.20 5.20 7.44 6.24 30 0.07 1.36 0.13 5.75 7.09 6.09 9.46 0.26 35 0.08 1.59 0.18 7.65 9.83 8.83 11.80 10.60 40 0.09 1.02 0.24 9.00 12.03 11.03 14.44 13.24 45 0.10 2.04 0.30 12.10 14.40 13.48 17.37 16.17 50 0.11 2.27 0.37 14.80 17.17 16.17 20.60 19.40 55 0.12 2.50 0.45 17.66 20.10 19.10 24.12 22.92 60 0.13 2.72 0.53 20.74 23.27 22.27 27.92 26.72 65 0.14 2.95 0.62 24.05 26.67 25.67 3201. 30.81 70 0.16 3.10 0.72 27.58 30.31 29.31 36.37 35.17 75 0.17 3.40 0.03 31.34 34.17 33.17 41.00 39.80 80 0.18 3.63 0.94 35.31 38.26 37.26 45.91 44.71 85 0.19 3.86 1.07 39.50 42.57 41.57 51.08 49.88 90 0.20 4.08 1.19 43.91 47.10 46.10 56.53 55.33 95 0.21 4.31 1.33 48.53 51.86 50.86 62.23 61.03 100 0.22 4.54 1.47 53.36 56.83 55.83 68.20 67.00 Wet Well Calculations Wet Well Diameter 5 ft Wet Well Height 10 ft Pump Rate 75 gpm 'Pump rate is where system curve and pump curve cross Min active wetwell volume: 1) Mn of tminute pump rate time 75 gallons 2) 10 minutes pump cycle time ( 3 cycles/hr/pump ) 187.5 gallons Dimensions ofsloped portion around base ofwetwell (ft): height= 1.00 width = 1.00 Volume perfootof depth ofwetwell : Volume of storage per ftofheight Depth (ft) Volume (gal) 147 gal/ft 0 0 1 100 2 247 3 394 4 540 5 687 6 834 7 981 8 1128 9 1275 10 1 1422 3 PUMP STATION CALCULATIONS C6 Scale: N/A flow rate into Wet Well Qin= scharge Flow Out of WetWell Qout= imum cycle time between starts Tmin= Storage Volume of Well ghtto start pump ime storage atpump start e to S tartPu m p from empty e to Empty From Start imum cycle time between starts 31 Cycle Time Ies per Day(12 Hours) Ies per hour cCycles per hour Wet Well 26.01 gpm 75.00 gpm Omin Vmin= I 93.751gal 5.24 ft 723 gal 25.39 min 9.65 min 5.00 min 14.65 min 23.70 cycles/12hr 1.97 cycl/hr 4.10 cycl/hr Minimum Submergence Hx Fd= 0.020 Hx= 0.175 ft Hmin= 4.775 ft System & Pump Curves - Regents School/Trinity Church 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 Flow (gpm) 0.058 cfs 0.167 cfs 0.42 hr 0.16 hr 0.08 hr 0.24 hr Pum p settings 1)Bottom ofwet well 488.00 ft 2)Pump Inlet 488.29 ft 2)AII pumps off 488.47 ft 3) Lead pump on 493.24 ft (Condition A) 4) Lag pump on 494.24 ft (Condition B) 5)High Water Alarm 495.24 ft 6)Top ofwet well 498.00 ft SYSTEM & PUMP CURVES C6 Scale: N/A Pump Selection Pump 5 Goulds WS_D4 Series Model. 3888D4 WS30D4 Oder No. WS3012D4 3 " (Solids) 4"Discharge Flange 1-Phase 230V 1750 RPM Max Amps: 21.5 Flow Pump 5 TDH (gpm) TDH (ft) 0 46.00 5 45.50 10 45.00 15 44.50 20 44.00 25 43.75 30 43.50 35 42.88 40 42.25 45 42.13 50 4200. 55 41.50 60 41.00 65 40.63 70 40.25 75 40.13 80 40.00 85 39.50 90 39.00 95 38.75 100 38.50 105 38.25 110 38.00 115 37.75 120 37.50 125 37.00 130 36.50 TDH - Max. TDH - Min. -*-Pump 5 SHIMP ENGINEERIN 32 LAND PLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM U Lie. 1 CENTRAL SEWAGE SYSTEM PLAN REGENTS SCHOOL ALBEMARLE COUNTY, VIRGINIA SUBMISSION: 2021.07.12 REVISION: FILE NO. 18.020 SANITARY SEWER PUMP STATION CALCULATIONS C6