Loading...
HomeMy WebLinkAboutSDP202000062 Review Comments Minor Amendment 2020-11-23 • .:.r?Nf:l!vl�. County of Albemarle Department of Community Development Memorandum To: Jonathan Garber—Lineage Architects From: Tori Kanellopoulos—Senior Planner Division' Planning Services Date: October 30, 2020 Updated November 23, 2020 with Fire/Rescue, VDOT and VDH comments Subject: SDP202000062— DS Tavern— Minor Amendment dated 08-18-20 The Planner for the Planning Services Division of the Albemarle County Department Community Development will recommend approval of the plan referred above when the following items have been satisfactorily addressed. (The following comments are those that have been identified at this time. Additional comments or conditions may be added or eliminated based on further review ) [Each comment is preceded by the applicable reference to the Albemarle County Code.] Planning (Tori Kanellopoulos) 1 18-4.1(b) and 18-32.7.5.1(c) Water supplies and sewer systems: Health Department approval for the proposed development is required. 2. 18-4.2 Critical slopes. a. Label all 'steep slopes' as 'critical steep slopes'. b. Critical slopes must be shown and labeled on all plan sheets. c. 18-4.2.3(b)Any proposed grading must be shown. Any disturbance of critical slopes requires a special exception and Board of Supervisors approval. 3. 18-21.7 and 18-4.20 Commercial districts—buffer requirement The site plan shows parking approximately 12 feet from the adjacent property, TMP 59-16A, which is zoned Rural Area. 18-21.7 requires a 20-foot undisturbed buffer for commercial uses adjacent tor residential and rural uses. The parking on preapplication plan SDP201900076 appeared to meet this requirement, however the parking shown on this site plan does not appear to. Either the parking must be revised to be at least 20 feet from the property, or a special exception must be requested. A special exception requires approval from the Board of Supervisors. Use buffer adjacent to residential and rural areas districts. For the purpose of this subsection, a use buffer shall not be required when a commercial zone is across a street from a residential or rural area district. No construction activity including grading or clearing of vegetation shall occur closer than 20 feet to any residential or rural areas district. Screening shall be provided as required in section 32.7.9 4. 18-4.20 Setbacks. Remove the 50' side yard setback on the plan sheets on the east side adjacent to TMP 59-15A1 —this parcel is zoned C-1 and therefore the 50' setback does not apply. This setback does apply to the west side adjacent to TMP 59-16A, as shown on the site plan. 5 18-4.12.13 Loading space. The ordinance requires one loading space for office uses under 8,000 square feet: 18-4 12.13(c): Loading spaces shall be provided in addition to and exclusive of any parking requirement on the basis of: (2) one space for the first 8,000 square feet of office space plus one space for each additional 20,000 square feet of office space. This requirement may be waived per 18-4.12.13(f). Provide a loading space meeting the dimension requirements of 18-4.12.18 or provide a justification as to why a loading space is not needed. 6. 18-32.5.2 Contents of an initial site plan and 18-32.6.2 Contents of a final site plan: a. Topography/applicable sheets: i Existing topography and any proposed grading need to be shown on site plan sheets. ii. Show critical slopes on all plan sheets as well to determine if any grading is disturbing critical slopes. b Work appears to be shown on the adjacent property TMP 59-15A1, including plantings. Include ownership information for this parcel on Sheet 1. c. Sheet 1: i. Revise title to "SDP202000062 Minor Amendment: DS Tavern". ii. Include the owner of the property on Sheet 1: Ivy Road RE LLC. iii. Include the tax map parcel on Sheet 1: 059000000015A0. iv. Include the proposed use of the development. E.g. 'building addition for X square feet of office space. X additional parking spaces, etc.'. v. Rename 'Geometry of Zone C-1'to 'Setbacks and Building Height C-1 Commercial Zoning District'. vi. Include the Zoning of the property on Sheet 1: 1. Property is split-zoned C-1 Commercial and RA Rural Area. 2. Property is located within the Entrance Corridor Overlay District. 3. Property is subject to proffers per ZMA198400026. 4. Property has Critical Steep Slopes. vii. Include the magisterial district of the property. Samuel Miller District. viii. Include that the property is located in the South Fork Rivanna Water Supply Watershed. ix. Include a note that the property is not within the ACSA jurisdictional area and does not have access to public water/sewer. x. Include one datum reference for elevation. d. Sheet 3: i. Revise Note 4—property is split zoned C-1 and RA. ii. The zoning district of adjacent properties has not been included. Revise to the following: TMP 59-15B: Zoned Rural Area TMP 59-15: Zoned Rural Area TMP 59-16A: Zoned Rural Area iii The zoning district and ownership information for TMP 59-15A1 must also be included on this sheet(zoned C-1 Commercial). e. Sheet 4: i. Remove Note 12 from Sheet 4. A Tier 3 groundwater study is required and is currently under review. The 03-19-20 determination was that a special use permit is not required for the proposed use. ii. Remove note on Sheet 4 'Net Plans approved by Khristopher Taggart May 22, 2020'. f. Show/label Route 250 ROW on applicable sheets. g More clearly show any existing known easements and their dimensions, and show them on applicable sheets, such as the shared driveway access easement. h With resubmittals, continue to update revision dates. i Include the full following requirement: The location of existing and proposed ingress to and egress from the site, showing the distance to the centerline of the nearest existing street intersection. 7. 18-32.7.9.4 Landscape plan/preservation of existing trees. Include the signed Conservation Checklist with the landscape plan. 8. Chapter 17 WPO/VSMP. Based on Engineering review, it appears land disturbance is less than 10,000 square feet; therefore, a WPONSMP application does not appear needed. If land disturbance is greater than 10,000 square feet, please note that a WPONSMP will be required and must be approved prior to site plan approval. Engineering (John Anderson) 1. See attached review comment letter dated 10-09-20. 2. See Engineering comments on Tier 3 Groundwater Study, attached and sent separately to applicant. Updated with resubmitted groundwater study:No remaining review comments on the groundwater study. VDOT(Adam Moore) 1 No objection to the site plan. A VDOT Land Use Permit is required prior to starting any work within the right of way. See attached letter dated 11-23-2020. Fire/Rescue (Shawn Maddox) 1. The travel way appears to exceed 150'without an emergency apparatus turn around. 2. Please provide the distance from the parking surface to the far corner of the two story addition. Any structures constructed must be within 150'where emergency vehicles will park. 3. Provide an ISO needed fire flow for the structure. Provide the current fire flow data from the closest ACSA hydrant. 4. A knox box will be required. A note indicating the requirement can be added to the plan with the location approved by the fire marshal's office. Inspections (Michael Dellinger) 1. Show accessible parking and aisle on CO-4. 2. Provide detail of accessible parking space and aisle on CO-6. 3. Identify accessible route to building from accessible parking space. 4. Accessibility must be in compliance with the VCC, VEBC, and ANSI A117.1-09. Virginia Department of Health (Alan Mazurowski) 1. See attached letter dated 11-18-20. Architectural Review Board (Khris Taggart) 1. No objection Please contact Tori Kanellopoulos in the Planning Division at vkanellopoulos a(�albemarle.orq or 434-296-5832 ext. 3270 for further information. s ,4i1/ 3a, "trJ tX ,_ ■C a. COMMONWEALTH of VIRGINIA DEPARTMENT OF TRANSPORTATION 1601 Orange Road Culpeper,Virginia 22701 Charles A. Kilpatrick,P.E. Commissioner November 23, 2020 County of Albemarle Department of Community Development 401 McIntire Road Charlottesville,VA 22902 Attn: Tori Kanellopoulos Re: DS Tavern—Pre-application Plan SDP-2020-00062 Review#1 Dear Ms. Kanellopoulos: The Department of Transportation, Charlottesville Residency Transportation and Land Use Section, has reviewed the above referenced plan as submitted by Linage Architects, dated August 18, 2020, and find it to be generally acceptable. A VDOT Land Use Permit will be required prior to any work within the right-of-way. The owner/developer must contact the VDOT Charlottesville Residency Land Use Section at(434) 422-9399 for information pertaining to this process. Sincerely, Adam J. Moore,P.E. Area Land Use Engineer Culpeper District VirginiaDOT org WE KEEP VIRGINIA MOVING r k' l t�',�Tj \:a f.)P" oaf.�r COMMONWEALTH of VIRGINIA In Cooperation with the Thomas Jefferson Health District ALBEMARLE•CHARLOTTESVILLE Stale Department of Health FLUVANNA COUNTY IPALMYRA) 1138 Rose Hill Drive GREENE COUNTY(STANARDSVILLE) LOUISA COUNTY{LOUISA) Phone(434)972-6219 P.O. Box 7546 NELSON COUNTY(LOVINGSTON) Fax (434)972-4310 Charlottesville,Virginia 22906 November 18, 2020 Tori Kanellopoulos Planner Albemarle County Community Development 401 McIntire Road Charlottesville,VA 22902 RE: DS Tavern SDP2020-62 Ms. Kanellopoulos: As requested, I've reviewed the Amended Site Plan (8/18/20) for the proposed construction referenced above. It does not appear the proposed construction will impact the existing septic tank or drainfield. I also would like to reiterate that there should be an assessment of the septic system by a professional engineer or other licensed consultant to ensure the system has adequate capacity for the proposed use of 4 full time employees land meetings of 30 persons. If there are any questions or concerns,please give me a call, 434-972-4306. Sincerely, e/Pa*--- Alan Mazurowski Environmental Health Supervisor Thomas Jefferson Health District alan.mazurowski@vdh.virginia.gov