HomeMy WebLinkAboutSDP202100030 Correspondence 2021-07-19 (2)VDOTVirginia Department
of Transportation
February 2015
ACCESS MANAGEMENT EXCEPTION REQUEST: AM-E
ACCESS MANAGEMENT REGULATIONS 24 VAC 30-73
SECTION 120
Submitted by: COLLINS ENGINEERING
Date: 7-14-2021
Email Address: scott@collins-enigneering.com
Phone: 434-293-3719
Address: 200 Garrett Street, Suite K Charlottesville, VA 22902
Project Name: Scott's Ivy Exxon
Rte # 250
Locality: Albemarle County
Description of Project:
Expansion of existing gas/service station including site improvements such as paved formal parking spaces. Redevelopment of
a commercial site with existing commercial retail and office buildings and an existing entrance. Existing continuous site
entrance is being split into two entrances (one partial access and one full access) by installing a landscaped island within the
existing continuous entrance. See attached narrative.
VDOT District: Culpeper
Area Land Use Engineer: Lauren Wilson
NOTES:
(1). Submit this form and any attachments to one of the District's Area Land Use Engineers.
(2). See Section 120 of the Regulations for details on the requirements, exceptions, and exception request review process.
(3). Attach additional information as necessary to justify the exception request(s).
(4). If a traffic engineering study is required, the decision on the request will be based on VDOT engineering judgment.
(5). Use the LD-440 Design Exception or the LD-448 Design Waiver forms for design and engineering standards, e.g. radius, grade, sight
distance. See IIM-LD-227 on VDOT web site for additional instructions.
Select the Exception(s) Being Requested
❑ Exception to the shared commercial entrance requirement. (Access M. Regulations Section 120 C.2)
Reason for exception:
❑ A. An agreement to share the entrance could not be reached with adjoining property owner.
❑ Attached: Written evidence that adjoining property owner will not share the entrance.
❑ B. Physical constraints: topography, adjacent hazardous land use, stream, wetland, other.
❑ Specify constraint:
❑ Attached: Documentation of constraint such as aerial photo or topographic map.
❑ Exception to the vehicular connection to adjoining undeveloped property requirement. (Section 120 CA)
Reason for exception:
❑ A. Physical constraints: topography, adjacent hazardous land use, stream, wetland, other.
❑ Specify constraint:
❑ Attached: Documentation of constraint such as aerial photo or topographic map.
❑ B. Other reason:
February 2015
❑ Exception to the commercial entrance shall not be located within the functional area of an intersection
requirement. (See Regulation Section 120 C. 1; Appendix F, Rd Design Manual)
❑ Attached: A traffic engineering study documenting that the operation of the intersection and public
safety will not be adversely impacted.
❑ ✓ EXCEPTION TO THE SPACING STANDARDS FOR:
• Commercial entrances; intersections/median crossovers (Table 2-2);
• Commercial entrances/intersections near interchange ramps (Tables 2-3, 2-4); or
• Corner clearance (Figure 4-4). Appendix F, Road Design Manual
Information on the Exception Request
✓❑ ON A STATE HIGHWAY
Functional classification: Principal Arterial: ❑ Minor Arterial: ❑✓ Collector: ❑ Local:
Posted speed limit: 35 mph
NEAR AN INTERCHANGE RAMP (Submittal of a traffic engineering study required)
CORNER CLEARANCE (Submittal of a traffic engineering study required)
Type of intersection/entrance: Signalized [=-] Unsignalized [=-] Full Access 2 Partial Access 2
Required spacing distance 250 ft
Proposed spacing distance 125 ft
Requested exception: Reduction in required spacing 125 ft
REASON FOR EXCEPTION:
✓❑ A. To be located on an older, established business corridor along a highway where existing spacing did
not meet the standards prior to 7/1/08 or 10/14/09. (Regulation Section 120 C.3.c)
❑✓ Attached: Dated aerial photo of corridor identifying proposed entrance/intersection location.
❑ B. Not enough property frontage to meet spacing standard, but the applicant does not want a partial
access right-in/right-out entrance. (Section 120 C.3.f)
❑ Attached: A traffic engineering study documenting that left turn movements at the entrance will not have a
negative impact on highway operation or safety.
❑ C. To be located within a new urbanism mixed use type development. (Section 120 C.3.d)
❑ Attached: The design of the development and compliance with intersection sight distance.
❑ D. The proposed entrance meets the signal warrants but does not meet the signalized intersection
spacing standard. The applicant requests an exception to the spacing standard.
❑ Attached: A traffic engineering study that (i) evaluates the location's suitability for a roundabout and (ii)
provides documentation that the proposed signal will not impact safety and traffic flow. (Section 120 C.5)
February 2015
❑ E. The development's 2"d (or additional) entrance does not meet the spacing standards but is
necessary for the streets to be accepted into the secondary system. (section 120 C.3.e)
❑ Attached: Information on the development that identifies the location of entrances.
❑ F. To be located within the limits of a VDOT and locality approved access management corridor plan.
❑ Attached: Aerial photo of corridor identifying proposed entrance/intersection location. (Sect 120 C.3.1b)
FOR VDOT USE ONL
Recommendation on Exception Request: Approveo Denyr Date:
Area Land Use Engineer or: Name
Remarks:
Exception Request Action: Approved❑ Denied❑ Date:
District Administrator or Designee:
Name (and position if Designee)
Remarks:
District Staff: Please email copy to Bradley.Shelton(cDVDOT.Virginia.gov
3
Additional information for 4260 Ivy Road Exception Request
This proposed Access Management Exception Request is for relief of the intersection spacing
requirement for the existing entrance into the site.
Site Conditions: This project is an expansion of the existing service station building on a property
owned by SR&DR LLC. The current use of the building is a service station and gas station. Along with
the expansion of the service station, the site is also being updated to include more formal paved
parking areas on site. The existing entrance to the site does not currently meet access management
standards. The entrance is being improved to meet current VDOT standards, but the spacing
between the entrances and the other existing entrances on the adjacent properties will not change,
and this spacing does not meet VDOT intersection spacing requirements.
Site Access: The existing entrance into the site is currently 165 feet long and across the entire site's
road frontage. This means vehicles can enter and exit anywhere along the site frontage. The project
proposes a large island to break up the frontage and create two points of access. The east entrance
will be a two-way entrance. The adjacent properties owned by Rivanna Water and Sewer Authority
and Louis & Susan Eaton have an access easement across the site to allow vehicles from the adjacent
properties to access Ivy Road (Route 250). It should be noted the access easement and entrance is the
only access point to Ivy Road for these adjacent properties. The western entrance is a one-way
entrance with site egress only. This allows for a better flow of traffic and limits points of conflict along
the site frontage. The distance between these two entrances is 124'. This exception request is for a
spacing exception between these two entrances. Attached are the images of the existing site
conditions from 2002 and site conditions from 2018 showing that access from these same areas have
existed and not changed over this period of time. This site plan proposes to improve this existing
condition to break up and limit points of access.
Below is a summary of the exception request. These intersections are shown on the attached exhibit.
The Highway functional classification of Ivy Road is a Minor Arterial roadway. The Posted speed limit is
35 mph. The existing entrance for the site is a full access intersection.
Exception Request for Intersection spacing between 2 entrances
Required Spacing Distance: 250 feet
Proposed Spacing Distance: 125 feet
Requested exception #1: Reduction in required spacing: 125 feet
Summary:
This exception request is for the approval of the spacing between the 2 proposed intersections created by
breaking up the continuous Ivy Road frontage along the site with an island. The entrances require a
spacing exception from the full access eastern entrance to the partial access western entrance (site
egress only). The eastern entrance requires a full access entrance for the existing access easement and
ability for vehicles from the adjacent properties to reach Ivy Road (Route 250). This proposal will improve
existing conditions along the site's frontage by restricting points of conflict along the existing entrance.
IWEE
rowE—Ewee
EX
x I
/ — 1
u uze 8 �x
R1R [r �urolE n.0 as -
xnxsry IF .n
ro
EmffisY� UP
w¢ e
rmwsEos
L os ANSIO
w oNGE PEFAYS — W > z
' smzwE .ssav cs ens OF EIVWAy 1—VExuro1—N.a.E—Erwcx. W 2 4
1..,E E. _ —x ��. o .. 3 z i
NIE
x1.,n..,
xrwarwn.s.a Z <
iA
a
Irwao. y.. P w rw W z U
s,.rsu em,ovun,uie r oa, a+ QY
Ex 4 N O 9g
Ell
— - — - — - — - — - — - — - — - — - — -r �. — — — Po.� O a
— — — — — — —„ — UN
Ell
m.rtn, U302199
m,usxss.s P UP CMPMC SCALE
1.
IF ,uu� GA sa1K+ ® 1 30 a
a rre�1,E ex axe.
Scott's Ivy Exxon Aerial Photo-2002
Legend
LWt (Nalco Some Xenia on map may not appear In legend)
'A, •� Parcel Info
�.' El Parcels
r58A2. _ -- '
SI tY all7 51 •
4250
1�
Y 4272 58A2-24C
r 58A2-20 _ •
�-. - 58A2-21 1
a
4282
4zeo ,
i � a
,-
94 ft , _ j�}/� _ nGISM
—�a, ra+ .`a gtp GerepMCGateaervicer
.Ibemade.orw'se
�� hBcrNtn (434)2=2
Any determination oltopagrapby or contour, or any deplNon a1 mysical Improvements, properly lines or rearmament k for general lnluructen only add shall not be used for Me aesiyl mMificatlon, or comtmNon of Improvements to real propel, orfor fil plain determination. July 13,2021
Map elements may scale larger than GIS data measured In the map or as provided on the data channel page due to Me projection used Map Pool WGS00 Web Mercator (Auxiliary SpMre) (EPSG 3057)
Any doIerminalion of topography or mMours, or am, deplNm Mphyslral improvements, property Imes or WoMerke Is for general Information ony and shall hat be usM for the design, mcNifimtion, or mrutmcllon of ImpravemeMs to real property or for fioM plain determination. July 13, 3021
Map elements may stale layer Man GIS data rreasued In tM map or as pro iged an Me data dowibad page due to Me pro)ectm used. Map Profecton: VA3S80 Wee Mermtor Mimallary Splare) (EPSG 3857)