HomeMy WebLinkAboutSDP202100061 Correspondence 2021-07-20LINE+GRADE C I V I L E N G I N E E R I N G July 19, 2021 Albemarle County Community Development 401 Mcintire Road, North Wing Charlottesville, VA 22902 Attention: William Fritz, AICP Development Process Manager RE: SDP202100061 Mountain View (Cale) Dear Bill Fritz, On behalf of Albemarle County School Board, we offer the following responses and plan revisions to comments dated July 16, 2021. Our Responses are in bold italic text below each comment. Albemarle Fire Rescue — Howard Lagomarsino >Mountain View Elementary 1) There needs to be access to all sides of the structure within 150 ft of the fire apparatus access route. The current configuration suggests the long axis of the modular is 64 ft and the short axis is roughly 24 ft. - based on this, the current configuration of the parking and proposed firelane provides this requirement. If different dimensions exist for the building, please provide the measurements of the exterior walls of the unit to ensure compliance. Please note, the long axis of the modular is 120', the short axis 64.' There will be access to all sides of the structure. Exterior dimensions for the new building are now included in the plan, sheet C2.0. 2) Please provide a note on the plan of the calculated ISO fire flow rate for the modular building. The modular building requires a Fire Flow of 1,500 gpm. Calculations can be found on sheet CO.1. L I N E + GRADE CIVIL ENGINEERING 113 4`^ STREET N E, STE. 100 CHARLOTTESVILLE, VA 22902 LINE-GRADE.COM SDP202100061 Mountain View (Cale) Comment Response Letter January 01, 20191 Page 2 3) 1 see an existing hydrant at the parking area but on the plans as presented to me, I can not conclusively calculate the distance from the hydrant to the building and without the ISO fire flow I cannot determine the spacing of hydrants or number of hydrants required. Please clarify on the plans the distance from this hydrant to the modular unit (furthest spacing distance permitted is 500 ft with no building more than 250 ft from a hydrant, however as fire flow requirement increases, the spacing is closer). Because the distance from the nearest hydrant to the modular unit is in excess of 250; the modular building shall include a fire suppression sprinkler system which shall be approved by the Fire Marshall prior to the Certificate of Occupancy being issued. 4) Please provide a note on the plan of the fire flow available from the hydrants. The existing hydrant has been labeled with the calculated flow rate on sheet C2.0, worksheet is included on sheet CO.1. 5) Please provide signage to alert that there is no parking at the end of the parking lot to ensure no one blocks the entrance to the portion of the fire lane to be constructed and to indicate no parking the length of the fire lane to construct itself. Signs have been added to the plan at the entrance to the new fire lane to prevent its obstruction. L I N E + GRADE r'.IV I I IF NC IN FFR INC 113 4th STREET NE, STE. 100 CHARLOTTESVILLE, VA 22902 LINE-GRADE.COM