HomeMy WebLinkAboutSDP200600076 Review Comments 2006-08-14 r . „4,4„4 A ;-,61,, ,4 4 1 y w 4 CCOMMO EALTH (OF VIRGIN IA DEPARTMENT OF TRANSPORTATION 1601 Orange Road Culpeper,Virginia 22701 VirginiaDOT.org GREGORY A.WHIRLEY ACTING COMMISSIONER August 14, 2006 Mr. Glenn Brooks Department of Engmeermg and Development 401 McIntire Rd. Subject: Site Review Meetmg Comments August 17th site review meeting Dear Mr.Brooks: Below are VDOT's comments on the Site Plans for the August 17th,2006 Site Review Committee Meeting: SDP-2006-00075 Crozet Gateway Center(David Pennock) • Look at extending the curbing along the entire frontage of the site including rte.240. • The final plan will need to mclude dramage calculations and pavement calculations. • The beginnmg of the turn lane should address the existing radius and 15 mch CMP and rework the radius and pipe to exclude the"notch"in the roadway. SDP-2006-00076 Boar's Head Inn Meeting Pavilion-Maior Amendment(Gerald Gatobu) • This work is all accessing private roads. • The increase in traffic at the intersection of rte.250 and Ednam Road should be indicated. • Show that the current intersection at rte. 250 is adequate,ie.turn lane dimensions, entrance grades,sight distances,and width. SDP-2006-00078 Old Trail Village Block 12(Francis MacCall) • Road C should be 36 feet wide unless parking is restricted on one side of the road. • VDOT has not received a traffic study showing impacts to Old Trail Road and the mtersections on rte.250 and 619. • For entrances with radii less than 25 feet,show that the design vehicle can adequately make the turning movement. • Drainage calculations and Pavement calculations need to be submitted with the final site plan. • Can someone send me a copy of Albemarle County's Neighborhood Model Development? 0 YES OF iRANSPo1M11019 EU(E i.NIr I 9 06 . . ' 20 :66 SDP-2006-00079 Berkmar Business Park—Major Amendment(Francis MacCall) • Existmg entrance needs to be checked and verified on the plan that it meets the current VDOT standards or needs to be upgraded. • Right turn lane needs to be 150 feet storage and 100 foot taper. • Need drainage and pavement calculations. SDP-2006-00080 Topeka's Steak House(Keith Lancaster) • All construction and connections are to private roads. • All mtersections with rte.250 have been modified with previous projects and are adequate. SDP-2006-00081 Black Cat Road Service Station(David Pennock) • Final plan needs to include road plans,typicals,pavement design, shoulder design,and drainage computations for rte. 616. • Show the turn lane and taper dimensions on rte. 616. Show the sight distance in both directions. • Show the entrance dimensions and profiles. • Plans must be in accordance with VDOT's Road Design Manual and the Minimum Standards of Entrances to State Highways. SDP-2006-00082 Wood Residence(Steve Ruswell) • Distance to property lines is needed • A narrative of plan revisions should accompany any resubmittal. • A typical section and an entrance profile is needed for this entrance. • Show location of entrance for field verification of sight distance. • Show entrance radius(25' minimum) and set the curb and gutter back from the EP 12' with a 48' (4:1)taper return to the existmg EP, as shown in the Minimum Standards of Entrances to State Highways on page 19. • Please provide a drainage easement for the pipe crossing the State Roadway. • Show all existing and proposed utility easements or add to the notes if there are none. • Show the ITE codes pertaining to this site and the projected traffic volumes from these codes. SUB-2006-00224 Rolling Meadows(Gerald Gatobu) • The intersection at rte.250 needs to show sight distance,turn lanes,and appropriate tie-in grades in accordance with VDOT's CG-11 standard. • Ditches need to be 3:1 or flatter. • Sheet 2 shows a 14 foot pavement width, sheet 3 shows 18 foot pavement width. The minimum width is 18 feet in this case. • The road needs to be designed in accordance with VDOT's Road Design Manual. • Pavement design,calculations,and drainage calculations need to be submitted with the final site plan. . a Please request the applicants submit a written descnption of the revisions when resubmitting for review. If you should have concerns with these comments,please discuss with this office prior to sharing with the applicants. Sincerely, Joel DeNunzio, P.E. Residency Program Manager VDOT Charlottesville Residency 434-293-0011 cc Alan Schuck, Bill Fritz, David Bemsh, Juan Wade, Blame Echols, Joan McDowell, Judith Weigand, Margaret Maliszewski, David Pennock, Steve Tugwell, Francis McCall, Keith Lancaster, and John Giometti