Loading...
HomeMy WebLinkAboutSUB202000224 Certified Engineer's Report 2020-11-30 ( Old Dominion Onsite Inc. Page 1 of 116 Sylvia Road, Suite A,Ashland VA 23005 OSE/PE Report for Subdivision Approval Property Location: 911 Address: 165 Mountain Vista Rd City Scottsville Lot Section Subdivision GPIN or Tax Map# TM 130-35A Health Dept. ID# Latitude 37 80569 Longitude -78.503546 Applicant or Client Mailing Address: Name: Hilton Patterson Street: 22 Quite Meadow Dr City, State, Zip Code: Stuarts Draft,VA 24477 Prepared by: OSE Name Donald Hackler License# 1940001231 Address 40 Deer Tail Ln City, State, Zip Code Louisa,VA 23093 PE Name License# Address City, State, Zip Code Date of Report: November 30,2020 Date of revision#1 AOSE/PE Job Number 1231-20-039 Date of Revision#2 Contents/Index of this report: 1. Cover Page 2. Site Evaluation 3 Soil Profile 4 Site Plan 5 Abbreviated Design Certification Statement ' I hereby certify that the evaluations and/or designs contained herein were conducted in accordance with the applicable provisions of the Sewage Handling and Disposal Regulations(12 VAC5-610),the Private Well Regulations(12 VAC5-630),the Regulations for Alternative Onsite Sewage Systems(12 VAC5-613),and all other applicable laws, regulations,and policies implemented by the Virginia Department of Health. I further certify that I currently posses any professional license required by the laws and regulations of the Commonwealth that have been duly issued by the applicable agency charged with licensure to perform the work contained herein.The potential for both-conventional and alternative onsite sewage systems has been discussed with the owner/applicant. The work attached to this cover page has been conducted under an exemption to the practice of engineering, specifically the exemtion in Code of Virginia Section 54.1-402.A.11 I recommend a Subdivis" n Approva be issu OSE/PE Signature Date /#1fr, �� OSE Job#: 1231-20-039 1 � Page 2 of 5 Health Department ID# Site and Soil Evaluation Report Due Date (For certification letters and subdivisions) Old Dominion Onsite Inc. 40 Deer Tail Ln Louisa,VA 23093 Tax Map/GPIN Ref: 130-35A 540-223-0172 General Information Date: November 13,2020 Albemarle County Health Department Applicant: Same as Owner Telephone No.: 434-547-5837 Address: Owner Hilton Patterson Address: 22 Quite Meadow Dr,Stuarts Draft VA 24477 Location: 165 Mountain Vista Rd Subdivision. Block/Section: Lot: Soil Information Summary 1.Position in landscape satisfactory Yes n No n Describe Side Slope 2. Slope 7-8 % 3.Depth to rock/impervious strata Max. 32"+ Min. 32" None n 4.Free Water No El Yes n Range in Inches 32" 5.Depth to seasonal water table(gray mottling or gray color) 32" inches 6. Soil percolation rate estimated Yes X Texture group nI nII rxim nIV No n Estimated Rate 70 min./inch at 18 inches 7.Percolation test performed Yes n Number of percolation test holes No M Depth of percolation test holes Average percolation rate mpi Name(s)and title(s)of evaluator(s): Donald Hackler AOS- # 19 001231 540-223-0172 Signature(s) /,01( ®Site Approved. Absorption trench dispersing TL-3 to be placed at 18 (inches)depth at site designated on permit. Site provides a total of 1800 square feet of absorption area for primary and reserve. ElSite Disapproved.Reasons for Rejection(check all that apply) 1 Position in landscape subject to flooding or periodic saturation. 2 Insufficient depth of suitable soil over hard rock. 3 Insufficient depth of suitable soil to seasonal water table. 4 Rates of absorption to slow. 5 Insufficient area of acceptable soil for required drainfield,and/or Reserve Area. 6 Proposed system too close to well. 7 Other—Specify Revised 12/1/2014 OSE Job#: 1231-20-039 • Page 3 of 5 Date of Evaluation: November 13,2020 Profile Description SOIL EVALUATION REPORT Property ID: TM 130-35A, Hilton Patterson Where the local health department conducts the soil evaluation the location of profile holes may be shown on the schematic drawing on the construction permit or the sketch submitted with the application.If soil evaluations are conducted by a private soil scientist, location of profile holes and sketch of the area investigated including all structural features i.e.sewage disposal systems,wells,etc. within 100 feet of site and reserve site shall be shown on the reverse side of this page or prepared on a separate page and attached to this form. Ei See application sketch ❑ See construction permit IN See sketch on reverse side or page attached to this form. Hole# Horizon Depth Description of color, texture, etc. Texture (Inches) Group 1 A 0-8 5YR 3/3 Loam II Bt1 8-18 2.5YR 5/3 Clay Loam III Bt2 18-32 2.5YR 5/6 Clay Loam III few fine faint 2.5YR 4/8 mottles from parent material few fine faint 2.5YR 6/4 mottles 32 free water 2 A 0-3 5YR 3/3 Loam II Bt1 3-22 2.5YR 6/3 Clay Loam III Bt2 22-32 2.5YR 5/6 Clay Loam III few fine faint 2.5YR 4/8 mottles from parent material few fine faint 2.5YR 6/4 mottles 32 free water 3 A 0-6 5YR 3/3 Loam II Bt1 6-14 2.5YR 6/3 Clay Loam III Bt2 14-24 2.5YR 5/6 Clay Loam III few fine faint 5YR 6/4 mottles Bt3 24-32 2.5YR 5/6 Clay Loam III few fine faint 2.5YR 4/8&6/4 mottles few fine dominant 7.5YR 7/6 mottles from parent material 32 free water I I I 4 A 0-2 5YR 3/3 Loam Bt1 2-10 2.5YR 6/3 Clay Loam Bt2 10-32 2.5YR 4/8 Clay Loam 32 free water I I III III REMARKS: Revised 12/1/2014 OSE Job#• 1231-20-039 • Cons �LIUction Drawings Page 4 of 5 Property ID: TMS 130-35A = _----- ------------------ No Well _ _______ - _______Mountain Vista Road within 100' / . _ -----__--- - / of Proposed X- ---- —_ ------------- Drainfield North -- �_ TL-3 Alternative Scale 1" = 60' x � Prrimary & Reserve 4 Ditches 75' Long 0 20 40 60 / Vacant 900 Sq ft provided 865 sq ft required / �x /� x .„--, ,� / • Existing ' '/' No Well / Well within 100' to be X of Proposed Abandoned Drainfield 0 96' r CD • Shed cp R. x New Parcel "A" #1 0 a) 2.90 Acres CO Q No Well SIOpe p ' within 100' • # , #2 of Proposed c9 Drainfield Q If Existing well is not Abandoned, Drainfield area will need to 20' ACSA`, • • move 4' due South Easement ,, \ Schematic drawing of sewage disposal system and topographic features. Show the'lot lines,of the_uil int\lot and building site, sketch of property showing any topographic features which may impact on the design bf the'system,KI existing and/or proposed structures including sewage disposal systems and wells within 200 feet of sewage disposal system andreei a area. The scale drawing of the sewage disposal system shall show sewer lines, pretreatment unit, pump station,conveyan0 system, a\id' ubsurface soil absorption system,reserve area,etc. When a nonpublic drinking water supply is to be located on the,same yot,show\all sources of pollution within 200 feet. \ ‘ \ No Well within 100' AOSE Job# 1231-20-039 \\�\\\\ of Proposed Drainfield \� ' \ \ \�\ \\ Abbreviated Design Form Page 5 of 5 This form is for use with gravity,pump to gravity,enhanced flow,and low pressure distribution(LPD)sewage system designs and when applying for a certification letter or subdivision approval. This abbreviated design covers the primary and reserve area for TM 130-35A,Hilton Patterson Design Basis Total length of available area: 75 Total width of available area: 67 Estimated Perc.Rate 70 at 18 in.(depth) Number of bedrooms 3 Conveyance Method: Pump Distribution method(specify): D-Box Dispersal system basis Table 1 AOSS Regs. LGMI required? No Effluent quality required: Primary-TL-3 Reserve-TL-3 Square feet per bedroom: 300 Total trench bottom area required: 900 Square feet per bedroom reserve 300 Total area for reserve 900 Area Calculations Number of trenches 4 (Note if a pad is used) Length of pad or trenches: 75 Width of pad or trenches: 3 Center to center spacing: 9 Reserve required? Yes Percent reserve area required: 100% Total width of absorption area required 67 Total trench bottom area provided: 900 4 Ditches 75' Long Reserve The required width is calculated by multiplying the center-to-center spacing by one less than the number of trenches and adding 1 trench width plus any required reserve area. If the topography is not uniform across the length of the site the trenches will need to flare apart on one end to maintain contour. When this occurs it is necessary to use a center-to-center spacing that accounts for the flair or the installer will not be able to fit the system within the approved area. It is perfectly acceptable to have more area available, especially up and down the slope, than is required. AOSE Form E Revised July 18,2007 AOSE Job# 1231-20-039