Loading...
HomeMy WebLinkAboutSDP202100054 Review Comments Initial Site Plan 2021-07-28V 401 McIntire Road, North WinCounty of Albemarle Charlottesville, VA22902-4579COMMUNITY DEVELOPMENT DEPARTMENT Telephone: 434-296-5832 W W W.ALBEMARLE.ORG Memorandum July 28, 2021 Holly Thatcher and Ryan Yauger 28 Blackwell Park Ln. Suite 201 Warrenton, VA 20186 HHatcher@bohlereng.com and rvaueer&bohlereng com RE: SDP202100054 Discount Tire Initial Site Plan To Whom It May Concern: The Site Review Committee has reviewed the development proposal referenced above. Initial comments from the following divisions of the Department of Community Development and other agencies, as applicable, are attached: Albemarle County Planning Services (Planner) Albemarle County Engineering Services (Engineer) Albemarle County Building Inspections Albemarle County Department of Fire Rescue Virginia Department of Transportation (VDOT) Albemarle County Service Authority (ACSA) Virginia Department of Health (VDH) Albemarle County Information Services (13911) Albemarle County Architectural Review Board (ARB) Rivanna Water and Sewer Authority Comments reflect information available at the time the development proposal was reviewed and should not be considered final. However, the Site Review Committee has attempted to identify all issues that will be required to be resolved prior to approval of the initial site plan. Please contact me at your earliest convenience if you have questions or require additional information. Sincerely, A=Z# / Kevin McCollum Planner Albemarle County Planning Services (Planner) —Kevin McCollum, kmccollum@albemarle.org —Required changes: Comments to be addressed prior to final site plan approval: 1. [32.7.5.2(d)] Revise the plan to provide additional planting area along the Rt. 29 frontage to accommodate required frontage trees free of utilities and easements. Note that this will likely require the elimination of the 8- space parking row and possibly some of the adjacent travelway. 2. [32.5.2(a)] Please correct the Tax Map and Parcel Number on the cover sheet and any additional TMP reference number on the Plans to say Tax Map and Parcel number or simply TMP instead of "PIN." 3. [32.5.2(a)(b)] Please include the following general information and information regarding the proposed use on the Cover Sheet. a. Zoning District — Highway Commercial b. Zoning Overlay Districts — Airport Impact Area and Entrance Corridor c. Please include a reference to the Initial Site Plan Number: SDP202100054 d. The proposed use and square footage of the building e. The schedule of parking and amount provided f Maximum building height permitted and the proposed building height 4. [32.5.2(b), 4.12.6] The parking schedule on Sheet C-301 suggests that there are 15 employees and 6 service bays for a total minimum parking requirement of 27 spaces. Section 4.12.4 of the Zoning Ordinance states that the total number of parking spaces provided may not exceed the parking requirements by more than 20 percent. 33 parking spaces is ((33-27)/27 = 0.2222) 22.22 percent more than the parking requirements. Please remove one parking space or revise the Plans accordingly. 5. [32.5.2(i)] Please see VDOT comment # 1 (attached). Provide pedestrian accommodations across the entrance. 6. [32.5.2 (k)(1), 32.6.2(g)] Any new easements required for water, sewer, drainage facilities, or any proposed utilities will need to be reviewed, approved, and recorded prior to final site plan approval. Please submit an easement plat application the County for review. The final site plan will need to be updated so that all easements are shown and labeled identifying easement type, whether it's public or private, a width dimension, and the recorded instrument with deed book and page number. 7. [32.7.8 and 4.17.41 Please use a light loss factor of 1.0 to determine footcandles on site. It is unclear what LLF factor was used on the Lighting Plan. 8. [32.7.8 and 4.17.4] Please add a note to which states "Each outdoor luminaire equipped with a lamp that emits 3,000 or more initial lumens shall be a full cutoff luminaire and shall be arranged or shielded to reflect light away from adjoining residential districts and adjacent roads. The spillover of lighting from luminaires onto public roads and property in residential or rural areas zoning districts shall not exceed one-half footcandle." 9. [32.6.2(h)] Please provide a signature panel for signature by each member of the site review committee. 10. [4.12.19(c)] On the final site plan, please provide a plan and profile view detail of the proposed dumpster enclosure. Identify the dimensions, materials, etc. 11. [4.12.19 (b)] Please show that concrete will be used as the surface material at the dumpster enclosure. The concrete pad must extend a minimum of 8' beyond the front of the dumpster. 12. [32.5.2 (q)] Please provide traffic generation figures. See VDOT comments for further information. 13. [32.7.2.1 (b)] Please see VDOT comment #4. The proposed entrances to the site do not meet VDOT spacing requirements, and VDOT has stated that an Access Management Exception (AME) needs to be approved in order to allow the proposed entrance location. Please coordinate directly with VDOT to address the AME requirement. 14. [32.7.9] The Site Plan currently shows a 25' landscape buffer along the property frontage. Why is this being provided? Is this an existing easement that applies to the property? Please contact Kevin McCollum at the Department of Community Development at kmccollum@albemarle.org or 296- 5832 ext. 3141 for further information. Comments From Other Reviewers: Albemarle County Engineering Services (Engineer) — David James, diames2@albemarle.org — Requested changes (7/19/2021). 1. Land disturbance is over 10,000 sf submit a VSMP application for review. 2. The VSMP plan will need to be approved and bonded before final plat approval. 3. Sheet 302: Show storm structure numbering, type & pipe size/length information. 4. Show dumpster pad & detail. 5. Provide safety railing for walls over 30in. high. 6. Proposed wall in steep slope area have a maximum height of 61 [30.7.5 A.] 7. Parking area exceed 5% slope. [4.12.15 c.] 8. Minimum sidewalk width is 5ft adj. to parking/travelways. 9. Stormwater management facilities are not shown or mentioned. If SWM BMPs are expected they should be shown because it could affect the overall site design layout. 10. Provide TWBW elevations at each comer and the max. height point(s) along wall. 11. Show graded areas over 3:1. Where grading is over 3:1 provide low maintenance (not grass) ground cover. 12. Provide drainage area maps, drainage structure tables. 13. Show proposed utility lines & structures and profiles. 14. Pedestrian crossing was removed at entrance. Provide CG-12, sidewalk & pedestrian crossing to existing sidewalks. 15. Note: VDOT entrance permit required prior to approval. 16. Provide guardrail before wall drop-off (where height is a foot or above). Albemarle County Building Inspections — Betty Slough, bslough&albemarle.org — Requested changes, see below (7/7/2021). 1. Add the following note to the general notes page: Accessible parking spaces, access isles, and accessible route shall be installed in accordance with ICC ANSI Al 17.1-09 and the 2015 Virginia Construction Code. 2. Add the following note to the general notes page: ALL water lines, sewer lines, and fire lines from the main to the structure located on private property MUST have a visual inspection performed by the building department. 3. Add the following note to the general notes page: Where the flood level rims of plumbing fixtures are below the elevation of the manhole cover of the next upstream manhole in the public sewer, the fixtures shall be protected by a backwater valve installed in the building drain, branch of the building drain or horizontal branch serving such fixtures. Plumbing fixtures having flood level rims above the elevation of the manhole cover of the next upstream manhole in the public sewer shall not discharge through a backwater valve. 4. Add the following to the general notes page: All roof drains shall discharge in a manner not to cause a public nuisance and not over sidewalks. 5. Add the following note to the general notes page: Buildings or structures built before January 1, 1985 must have an asbestos survey performed in order to apply for a demolition permit. Asbestos removal permits are required if positive for such from Albemarle County and VDOLI. Contact VDOLI for their additional requirements and permits for demolition projects at 540-562-3580 x131. Albemarle County Department of Fire Rescue — Howard Lagomarsino, hlaQomarsinogalbemarle.org — Requested changes, see below (7/7/2021). 1. Emergency/fire vehicle access road/route needs to provide an unobstructed travel way width of 20 ft. if buildings/structures are under 30 feet tall and 26 ft. if buildings/structures are over 30 feet tall and extend so that all sides of the ground level are within 150 ft of the fire apparatus. To ensure these stay unobstructed, no parking signs are needed on the north and south sides of the building 2. Please provide as a note on the plans the ISO required fire flow for the building. 3. Hydrants need to be spaced according to the requirements that are based on the required fire flow (generally, no building is to be more than 250 feet from a hydrant, but a requirement for increased fire flow may require closer distances). Please indicate the location of the closest hydrant(s) and provide a note on the plan with the fire flow available to ensure it meets the ISO calculated flow. 4. A Knox Box will be required. Please place a note indicating this on the plan. The location of this can be coordinated with the Fire Marshal's Office. Please place a note on the plan acknowledging this Virginia Department of Transportation — Adam Moore, Adam.Moorekvdot.vir iginia.gov and Doug McAvoy Jr., douglas.mcavoy@vdot.vir iginia.gov—Requested changes, see attached (6/24/2021). Albemarle County Service Authority — Richard Nelson, rnelson@serviceauthority.org — Requested changes (7/23/2021). 1. Provide fixture counts to confirm the existing 5/81' meter can be reused. 2. Add a note on the demo plan that water/sewer services will be required to be disconnected prior to demo permit approval. 3. Confirm sewer lateral size. Confirm if an existing sewer lateral can be reused. 4. Confirm water service line depth going to 1640 Seminole Trail. 5. Confirm trees are outside of the ACSA sewer easement. Virginia Department of Health —Alan Mazurowski, alan.mazurowski@vdh.virginia.gov —No objection (7/12/2021). Albemarle County Information Services (E911) —Elise Kiewra, ekiewra@albemarle.org -No objection (6/22/2021). Albemarle County Architectural Review Board (ARB) — Khristopher Taggart, ktaeQart@albemarle.org — Requested changes, see attached (7/20/2021). Rivanna Water and Sewer Authority —Victoria Fort and Dyon Vega, vfort@rivanna.org and dvega@rinavvan.org — No Objection (7/7/2021). COMMONWEALTH of VIRGINIA DEPARTMENT OF TRANSPORTATION Stephen C. Brich, P.E. 1401 East Broad Street Commissioner Richmond, Virginia 23219 June 24, 2021 County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Attn: Kevin McCollum Re: Discount Tire — Initial Site Plan SDP-2021-00054 Review # 1 Dear Mr. McCollum: (804) 7862701 Fax: (804) 7862940 The Department of Transportation, Charlottesville Residency Transportation and Land Use Section, has reviewed the above referenced plan as prepared by Bohler, dated 4 June 2021, and offers the following comments: 1. There are no pedestrian accommodations shown across the entrance. Please add the crosswalk and CG-12 to the Plans. 2. Provide anticipated traffic generation numbers. 3. Provide turn lane warrants for Route 29. 4. Entrances do not meet spacing requirements; an Access Management Exception will be required. 5. Sight distance shown (465 ft) does not conform with the requirement of 500 ft in Table 2- 5 in Appendix F of the Road Design Manual. Please correct the problem, explain the discrepancy, or apply for a Design Waiver. 6. Please provide sight -distance profiles along the sight -distance lines. 7. Please show limits of mill and overlay in full lane widths required to complete this work on plans, ensuring compliance with Standard Drawing WP-2. Also, please add the WP-2 detail to the plans. 8. Video inspection of the existing stormwater pipe will be required to confirm it's condition before tying -in private lines. 9. Provide drainage calculations. 10. The Developer is proposing to remove two of the three architectural street lamps that fall within the right-of-way between the lateral limits of the subject property. VDOT is opposed to this, and requests a meeting to discuss conservation and relocation. 11. Note that the final plan must show conformance with the VDOT Road Design Manual Appendices 13(1) and F, as well as any other applicable standards, regulations or other requirements. VirginiaDOT.org WE KEEP VIRGINIA MOVING June 24, 2021 Attn: Kevin McCollum Please provide a digital copy in PDF format of the revised plan along with a comment response letter. If further information is desired, please contact Doug McAvoy Jr. at (540) 718-6113. A VDOT Land Use Permit will be required prior to any work within the right-of-way. The owner/developer must contact the Charlottesville Residency Transportation and Land Use Section at (434) 422-9399 for information pertaining to this process. Sincerely, Adam J. Moore, P.E. Area Land Use Engineer Charlottesville Residency �1 OF `ttR County of Albemarle Community Development Department - Planning July 20, 2021 Katherine Roberts, P.E. Bohler Engineering 28 Blackwell Park Lane, Suite 201 Warrenton, VA 20186 RE: ARB-2021-67: Discount Tire Initial Site Plan (TMP: 06100-00-00-120J0) Dear Applicant, Khristopher Taggart ktaooart@albemarle.org Telephone: (434) 296-5832 ext.3278 At its meeting on Monday, July 19, 2021, the Albemarle County Architectural Review Board unanimously voted to forward the following recommendations on the above -noted Initial Site Development Plan to the agent for the Site Review Committee: Regarding requirements to satisfy the design guidelines as per § 18-30.6.4c(2), (3) and (5) and recommended conditions of initial plan approval: o The ARB recommends approval of the Initial Site Plan with the following condition: Revise the plan to provide additional planting area along the Rt. 29 frontage to accommodate required frontage trees free of utilities and easements. Note that this will likely require the elimination of the 8-space parking row and possibly some of the adjacent travelway. • Regarding recommendations on the plan as it relates to the guidelines: None. Regarding conditions to be satisfied prior to issuance of a grading permit: None. Regarding the final site plan submittal: A Certificate of Appropriateness is required prior to final site plan approval. The following items and all items on the ARB Final Site Plan Checklist must be addressed: 1. Provide samples for all materials and colors. 2. Revise the masonry to one with a more finished appearance. 3. Revise the building forms to establish a more cohesive appearance for the overall building. 4. Revise the design of the north elevation to incorporate architectural detailing to relieve blankness. 5. Revise the size of building forms and the distribution of materials and colors to create a better sense of human scale and greater coordination throughout the building. 6. Revise the color of the ACM to a more muted, earth tone color. 7. Revise the architectural drawings to include the standard window glass note: Visible light transmittance (VLT) shall not drop below 40%. Visible light reflectance (VLR) shall not exceed 30%. Specifications on the proposed window glass should be submitted with the application for final review. 8. Show the location of mechanical equipment (building and ground mounted) on the site and architectural plans and show how it will be screened from the EC. 401 McIntire Road, North Wing, I Charlottesville, VA 22902-4579 9. Revise the site plan to provide a dumpster enclosure detail. A material that coordinates with that approved for the main building would be appropriate. 10. Add the standard mechanical equipment note to the site plan and architectural drawings: "Visibility of all mechanical equipment from the Entrance Corridor shall be eliminated." 11. Revise the photometric plan to indicate that the plan was calculated using an LLF of 1.0 for all fixtures and revise the photometrics accordingly. 12. Revise the color temperature of the pole -mounted lighting to a soft, warm white (3000K). 13. Revise the lighting plan to indicate the color temperature for the under -canopy lighting. A lighting temperature of 2000K-3000K would be appropriate. 14. Revise the height of the pole -mounted fixtures to a height that does not exceed 20', including the base and indicate this on the plan. 15. Add the standard lighting note to the lighting plan: "Each outdoor luminaire equipped with a lamp that emits 3, 000 or more initial lumens shall be a full cutoff luminaire and shall be arranged or shielded to reflect light away from adjoining residential districts and away from adjacent roads. The spillover of lighting from luminaires onto public roads and property in residential or rural areas zoning districts shall not exceed one half footcandle." 16. Revise the plan to provide additional planting area along the Rt. 29 frontage to accommodate required frontage trees free of utilities and easements. Note that this will likely require the elimination of the 8-space parking row and possibly some of the adjacent travelway. 17. Revise the site plan to provide a planting area along the north elevation of the building. 18. Revise the site plan to include the standard landscaping note: "All site plantings of trees and shrubs shall be allowed to reach, and be maintained at, mature height; the topping of trees is prohibited. Shrubs and trees shall be pruned minimally and only to support the overall health of the plant." 19. Revise the plan to show a pedestrian way across the frontage with the new development. 20. Add planting beds along the retaining walls to allow for trees at 2.5" caliper and shrubs at 24". 21. Revise the plan to indicate retaining wall material, color, manufacturer. A block in a muted, earth -tone color would be appropriate. Samples may be required. 22. Terrace all retaining walls over 6' in height and provide planting beds. 23. Revise the plans to correct the depth of the landscape buffer. 24. Please note separate sign applications are required for all proposed signs. The following preliminary comments are provided: a. Revise the wall signs to use either face illumination or halo illumination. b. Revise the sign proposed on the south elevation so that it has a more coordinated appearance. This can be done by reducing the size of the sign and/or changing the layout to a single line of text. c. The background of any cabinet signs proposed will be required to have an opaque background if internally illuminated. d. Include the size of the existing freestanding sign on the sign drawings. If the sign is taller than 12' and larger than 32 square feet, the proposal must include a 25% reduction in height and area until the height reaches 12' and area reaches 32 sf. 25. Provide a perspective showing the view of the north elevation from the street. 26. Consider reducing the width of the travelway on the north side to create planting area at the building. 27. Update the rendering to accurately show the scale and type of the proposed building materials. NWITL"A AA It 74 LTA I_\ 74 :1111591 ZTCI 401 McIntire Road, North Wing, I Charlottesville, VA 22902-4579 If you have any questions concerning any of the above, please feel free to contact me. Sincerely, i Khris Taggart, Planner cc: Mimosa LLC, ATTN: Frank Birckhead C/O Duffy Birckhead P.O. Box 7652 Charlottesville, VA 22906 Halle Properties C/O Discount Tire — Matthew Johnson 20225 N. Scottsdale Road Scottsdale, AZ 85255 File NWITL "Iw_\lU7"- T_\ VW*Wd 401 McIntire Road, North Wing, I Charlottesville, VA 22902-4579