Loading...
HomeMy WebLinkAboutSDP202100056 Review Comments Final Site Plan and Comps. 2021-08-04t� OF ALB County of Albemarle COMMUNITY DEVELOPMENT DEPARTMENT �tBGIN�P' Site Plan review Project title: Airport Road Pump Station - ESP Project file number: SDP202100056 Plan preparer: Bradley J. Weiss, PE, SEH [bweiss e sehinc.com ] 3535 Vadnais Center Drive, St. Paul, MN 55110 Owner or rep.: Michelle S. Simpson, PE [msimpson e rivanna.org ] Rivanna Water and Sewer Authority 695 Moores Creek Lane, Charlottesville, VA 22902 Plan received date: 30 Jun 2021 Date of comments: 4 Aug 2021 Plan Coordinator: Andy Reitelbach Reviewer: John Anderson Engineering has reviewed the final site plan and offers these review comments. 401 McIntire Road, North Wing Charlottesville, VA 22902-4579 Telephone:434-296-5832 WWW.ALBEMARLE.ORG 1. Recommend revise plan title to include ref. to SDP202100056. 2. Revise TO to include reference to related plan, WPO202100035. 3. Revise sheet list, TO I, to remove ESC-SWM-PPP (WPO plan -related) sheets from the final site plan. 4. Revise TO topography note to confirm existing topography has been at least visually verified within the last 12 months [See Final Site Plan checklist forplan reviewers, p. 1, Existing conditions plan view information, 2nd item —ref. attached]. 5. Coordinate final site plan design with VDOT. VDOT has near -term plans to extend Berkmar Drive Ext. to Airport Drive. Ensure that the final site plan proposed grade (final contours) are consistent with roadway extension. At present, they are not. Proposed grade suggests relatively abrupt rise into the site, with gradual fall, west to east, across the site. Ref. sheet C 12 Grading Plan. If grade is to be flatter, consistent with future Berkmar Drive Ext. roadway, then grades must be lowered across the site. Retaining walls may be required between proposed development and parcel to immediate north in order to eliminate 4'-5' grade rise at entrance to RWSA pump station. Retaining walls are a common remedy for addressing grade issues. Retaining wall ht. > 4-ft. requires a sealed geotechnical retaining wall design. Please coordinate directly with VDOT on Berkmar Drive Ext. (future) design, and accommodate reasonably -predictable VDOT Berkmar Drive Ext. future design needs. Note: Virtually all sheets of the FSP show and label Anticipated VDOT Grading Easement (Typ.), yet the ESP proposes grades that conflict with Berkmar Drive Ext. future grading. Please revise ESP consistent with anticipated VDOT Grading Easement. 6. Please remove sheet C09 bioretention basin specific design elements (footprint with label is fine), as well as sheets C10, C11, C13, C16, DC03 from the site plan since ESC measures and SWM facilities are not approved with a site plan, but with a WPO plan. WPO plan review is pending (WPO202100035). 7. C 12: Provide final disposition of runoff along south side of site access, specifically: provide channel lining design and velocity/capacity calculations for runoff in ditch -line between contours 623 and 615. Proposed grade routes runoff to a bend in site access, at which point runoff appears to sheet across site access without routing to any SWM capture or conveyance system. Include a new Drainage Plan sheet that shows storm runoff collection and conveyance. 8. With WPO Plan, account specifically for increased sheet flow from impervious parking and site access (reasonably anticipated to occur) along south side of development, given close proximity to property line. Engineering Review Comments Page 2 of 2 9. C 15: Engineering defers to Planning Division as to whether proposed grading within 20.0' undisturbed landscape buffer qualifies as undisturbed. C08 Existing Conditions, accurately describes existing condition as `existing wooded area mix of deciduous and evergreen trees.' The site is 100% mature canopy mix. If mature mix of deciduous and evergreen trees is removed, replacements will not attain maturity for decades. Engineering defers to Planning, but if site grade is lowered, generally, it may be not only feasible but relatively easy to preserve 20.0' undisturbed landscape buffers along parcel boundaries, for the entire development. Engineering encourages design to preserve an undisturbed landscape buffer to the maximum extent practical. Retaining walls may aid in addressing this and other review comments. Please feel free to call if any questions: 434.296-5832 -x3069 Thank you J. Anderson SDP2021-00056 Airport Road Pump Station FSP 080421.doc