Loading...
HomeMy WebLinkAboutSUB202000173 Plan - Approved 2021-08-04GENERAL NOTES APPROVED by the Albemarle County Community Development Department Date 8/4/21 File SUB202000173 OWNER: STANLEY MAR77N COMPANIES LLC 11710 PLAZA AMERICA DRIVE, SUITE 1100 RESTON, VA 20190 DEVELOPER: STANLEY MARTIN HOMES 404 PEOPLE PLACE, SUITE 303 CHARLOTTESVILLE, VA 22911 ENGINEER: COLLINS ENGINEERING 200 GARRETT ST SUITE K CHARLOTTESVILLE, VA 22902 (434)293-3719 TAX MAP NO.: 090000-00-00-03100 (DB 5237, PG.405) 1960 AVON STREET EXTENDED CHARLOTTESWLLE, VA 22902 TOTAL AREA: 5.262 ACRES ZONING: PRO PLANNED RESIDENTIAL DEVELOPMENT (ZMA 2012-0004 & ZMA2014-6) A VARIA77ON IS BEING REQUESTED WITH THIS INITIAL SITE PLAN AND PRELIMINARY SUBDIVISION PLAT PROPOSED USE: RESIDENTIAL DEVELOPMENT - TOTAL 30 RESIDEN7AL LOTS 28 SINGLE FAMILY ATTACHED RESIDENTIAL UNITS (TH UNITS) 2 EXISTING SINGLE FAMILY DETACHED RESIDENTIAL UNIT DENSITY- ALLOWABLE DENSITY PER ZMA APPLICA7ON PLAN: 6 DU/AC TOTAL ALLOWABLE NUMBER OF LOTS. 30 TOTAL LOTS TOTAL NUMBER OF PROPOSED UNITS 30 RESIDENTIAL LOTS PROPOSED VARIATIONS A VARIAT70N TO THE APPROVED APPLICATI0N PLAN IS BEING SOUGHT WITH A WAIVER REQUEST THAT SHALL ACCOMPANY THE REWEW AND APPROVAL OF THIS INITIAL SITE PLAN AND PRELIMINARY SUBDIVSION PLAT. THE WAIVER SHALL INCLUDE A MODIFICATION TO THE LAYOUT FROM THE ORIGINAL APPLICATION PLAN, A MODIFICATION TO THE ROADWAY NETWORK (BUT WILL KEEP THE SAME ROADWAY CONNECTIONS), A MODIFICA7ON TO THE SETBACKS (BASED ON THE ROADWAY CHANGES), AND A MODIFICATION TO THE TIMING OF THE INSTALLATION OF THE LANDSCAPING BUFFER AREAS AND SCRIM FENCE. OPEN SPACE: TOTAL OPEN SPACE PROPOSED = 1.328 AC (25.27) OPEN SPACE A: 6,850 SF OPEN SPACE B. 50,999 SF TOTAL OPEN SPACE REQUIRED (25%) = 1.316 ACRES OPEN SPACE TO BE OWNED AND MAINTAINED BY THE HOMEOWNERS ASSOCIATION. ALL OPEN SPACE SHALL BE RESERVED IN A DEED FOR THE COMMON USE OF LOT OWNERS IN THE SUBDIVISION AND NO OPEN SPACE IS PROPOSED TO BE DEDICATED PUBLIC SPACE. BUILDING HEIGHTS MAXIMUM BUILDING HEIGHTS SHALL NOT EXCEED 30 FEET RECREATIONAL AMENITIES PER PROFFER //8, 7HE OWNER SHALL PROVIDE AND INSTALL A 40'x5O' FENCED DOG PARK WITH (2) SMALL BENCHES AND (2) ADDITIONAL PLAY STRUCTURES FOR OLDER CHILDREN IN THE EXIS77NG TOT LOT AREA ON TMP090FO-00-00-OOA1, OWNED BY THE AVON PARK COMMUNITY ASSOCIA770N. SETBACKS: FRONT.- 10' MINIMUM (18' MINIMUM FROM R/W OR EDGE OF SIDEWALK TO GARAGE) SIDE. • NONE - MIN. 10' BUILDING SEPARATION REAR: 10' MINIMUM (LOTS 1-4 & 13-28) 5' MINIMUM (LOTS 5-12) SUBDIVSION STREETS: CURB & GUTTER WA7ERSHED: RIVANNA RIVER DRAINAGE DISTRICT - NOTE.- THIS SITE IS NOT LOCATED WITHIN A PUBLIC WATER SUPPLY RESERVOIR WATERSHED. AGRICULTURAL/ FORESTAL DISTRICT. NONE TOPO & SURVEY: THE BOUNDARY LINE AND PARCEL INFORMA7ON WAS PROVIDED BY ROUDABUSH, GALE AND ASSOCIATES MAY 2018. THE TOPOGRAPHY INFORMATION IS BASED ON FIELD SURVEY COLLECTED IN MAY 2010. THE PROPERTY IS CURRENTLY BE SURVEYED FOR UPDATED TOPOGRAPHY FOR THE FINAL SITE PLAN. INFORMATION FIELD VERIFIED BY COLLINS ENGINEERING MARCH 2O20. DATUM: NAD 83 EXISTING VEGETATION: PAR77ALLY WOODED WITH (2) RESIDENCES ON THE PROPERTY AND EXISTING GRAVEL DRIVEWAYS. LIGHTING: NO STREET LIGHTING IS PROPOSED WITH THE DEVELOPMENT. PARKING: PARKING REQUIRED: 2 SPACES PER UNIT + (1 SPACE PER 4 SFA UNITS) 28 SFA UNITS + 2 SFD UNITS = 60 OFF-STREET PARKING SPACES 7 ON-STREET/SURFACE PARKING SPACES TOTAL PARKING SPACES REQUIRED: 67 SPACES PARKING SPACES PROVIDED (MINIMUM (1) DRIVEWAY SPACE + (1) GARAGE SPACE): OFF-STREET PARKING SPACES: (2) SPACES PER LOT = 60 SPACES ON-STREET/SURFACE PARKING SPACES PROVIDED FOR GUEST PARKING = 21 SPACES TOTAL PARKING SPACES PROVIDED: 81 TOTAL PARKING SPACES PHASING: THIS PROPERTY SHALL BE DEVELOPED WITHIN 1 PHASE. BUILDING SITES PARCELS 1-30 EACH CONTAIN A BUILDING SITE THAT COMPLIES WITH THE REQUIREMENTS OF SECT70N 4.2.1 OF THE ALBEMARLE COUNTY ZONING ORDINANCE. BURIAL SITES NO KNOWN CEMETERIES EXISTS ON THE PROPERTY. STREAM BUFFERS. THERE ARE NO WO 100' STREAM BUFFERS ON THIS PROPERTY. ANY STREAM BUFFER SHALL BE MANAGED IN ACCORDANCE WITH THE ALBEMARLE COUNTY WATER PROTECTION ORDINANCE. WETLANDS/STREAMS. THERE ARE NO WETLANDS OR STREAMS LOCATED ON THE PROPERTY. FLOODPLAIN: THE PROPERTY LIES IN AN AREA DESIGNATED AS ZONE X AS SHOWN ON THE FLOOD INSURANCE RATE MAP COMMUNITY PANEL NO. 51003C0407D, DATED FEBRUARY 4, 2005. CRITICAL SLOPES THERE ARE PRESERVED SLOPES ON THE PROPERTY. MANAGED SLOPES ARE SHOWN ON 7HE PROPERTY BASED ON THE ALBEMARLE COUNTY GIS MAPPING FOR THIS PARCEL. THESE MANAGED SLOPES ARE SHOWN ON SHEET 2 AND SHEET 4 AND SHALL BE MANAGED IN ACCORDANCE WITH THE ALBEMARLE COUNTY ZONING REQUIREMENTS. RETAINING WALLS: RETAINING WALLS GREATER THAN 36" IN HEIGHT ARE NOT PROPOSED WITH THIS PLAN. LANDSCAPING: STREET TREES ARE PROPOSED ALONG THE NEIGHBORHOOD STREETS IN ACCORDANCE WITH ALBEMARLE COUNTY LANDSCAPING REQUIREMENTS WITHIN SECTION 32.7.9 OF THE COUNTY CODE. IN ADDITIONAL, LANDSCAPING BUFFERS SHALL BE PROVIDED ALONG THE BOUNDARY OF THE PROPERTY IN ACCORDANCE WITH THE APPROVED APPLICATION PLAN AND PROFFERS. SEE THIS SHEET AND SHEET 3 FOR ADDITIONAL INFORMATION ON THE REQUIRED AND PROPOSED LANDSCAPING BUFFERS. ALL LANDSCAPING BUFFER AREAS SHALL BE INSTALLED PRIOR TO THE FIRST CERTIFICATE OF OCCUPANCY. TRASH. EACH LOT SHALL HAVE AN INDIVIDUAL TRASH CONTAINER TO BE STORED WITHIN THE GARAGE. STORMWATER MANAGEMENT • ONE UNDERGROUND DETENTION FACILITY AND A DETENTION POND ARE PROPOSED WITH THE DEVELOPMENT TO ACCOMMODATE THE WATER QUANTITY REQUIREMENT FOR THE PROJECT. WATER QUALITY SHALL ACCOMPLISHED WITH THE PURCHASE OF NUTRIENT CREDI IS. AVON PARK II DEVELOPMENT ROAD PLAN SUB2020000173 SCOTTSVILLE DISTRICT - ALBEMARLE COUNTY. VIR6INIA N/F JENNIFER L CERARDI F- x — x DBx 4757 FE 433- x � o + TMP x \\N/F ALBEMARLE COUNTY I `y '-� SERVICE AUTHORITY x �; - -BB- 3571-PG 272x _ x -1 2r ---------------�- 1 l -- ! 1-4 ------- I � LOT LOT LOT LRT 4 3 2 LOT 7 F- LOT I LOT y ___----- L10T LOT 11 I L— LOT 12 i TMP 90-30 N/F GARY D BROOKS JR DB 4858 PC 406 ( IN FEET ) 1 inch = 50 ft- MILL CREEK VILLAGE c HOMES III a°` pax VON PARK - SITE y w a VICINITY MAP SCALE: 1" = 2000' 0 \ \ -- ---- IMP 90E-6 \ N/F DANEIL SHUMATE DB 4091 PC 534 \ TMP 90E-7 \ TMP 90E-9 TMP 90F 8 N/F IAN FARIS TMP 90-32A N/F DENNIS OR N/F ICNACI OR DB 4163 PC 261 N/F ROBERT SPAULS \ LINDA V OCONNOR TARA L D DB 982 PC 365 DB 4184 PC 210 CARDENA TMP 9OF-Al DB PC 77 N/F AVON PARK COMMUNITY ASSOCIATION INC C/O \ REAL PROPERTY INC \ DB 3692 PC 319 ----�T_ T T- Z---- ------------- LOT LOT LOT LOT LOT LOT 28 27 26 25 24 23 OPEN SPACES \ AREA B 50,989 SF Ll _— — LOT \� -LOT 29 - --- — - — - — -- 40,020SF 0.83ACRES 0.92 ACRES Q 1 LOT LOT T LOT LOT LOT LOT 22 i 19 20 21 -^ — 1-_ I - L 1 I - - ---------I TMP 90-30A N/F CARY D OR MYRTLE T BROOKS DB 1191 PC 396 IMPERVOUS AREAS. THE TOTAL OVERALL SITE IMPERVIOUS AREA CAN NOT EXCEED 379 PER THE APPROVED ZMA APPLICA7ON PLAN: ROADS: 0.63 AC (PAVED CIRCULATION PARKING AREA = 27,380 SF) SIDEWALKS: 0.11 AC BUILDINGS/DRIVEWAYS 1.12 AC TOTAL: 1.86 AC (35.3% IMPERVIOUS AREA) PROPOSED USES: LOTS. 127,162 SF (2.919 AC) ROADS (R/W & PRIVATE ACCESS ESMT): 44,200 SF (1.015 AC) OPEN SPACE. 57,849 SF (1.328 AC) OFFSITE EASEMENT ALL PROPOSED GRADING SHALL BE CONSTRUCTED ON SITE OR WITHIN EXISTING RIGHT-OF-WAY. THERE ARE ALSO EXISTING OFFSITE EASEMENTS FOR THE ROADWAY AND UTILITY CONNECTIONS TO THE AVON PARK DEVELOPMENT. NOTES: 1) THIS PROPERTY DOES NOT LIE WITHIN AN AGRICULTURAL AND/OR FOREST DISTRICT. 2) ONLY (1) DWELLING PER LOT SHALL BE PERMITTED. 3) ALL PROPOSED EASEMENTS SHALL BE DEDICATED TO PUBLIC USE. 4) STREET TREES SHALL BE PROVIDED ALONG ALL THE PUBLIC STREETS 40' O.C. IN ACCORDANCE WITH VDOT AND ALBEMARLE COUNTY STANDARDS. 5) THIS PROPERTY IS NOT LOCATED WITHIN A DAM INUNDATION ZONE. LEGEND EDGE OF PAVEMENT CURB PROPOSED ASPHALT PA VEMENT EXISTING VEGETATIVE/LANDSCAPE BUFFER GREEN WAY BUFFER PROPOSED EASEMENT Q DROP INLET & STRUCTURE NO. DRAINAGE PIPE BENCH MARK 4 VDOT STANDARD STOP SIGN PROPOSED HANDICAP PARKING SPACE « PROPOSED ASPHALT STRIPING zoo EXISTING CONTOUR 200 PROPOSED CONTOUR TMP 90-30B N/F JOHN A OR RUBY T BROOKS DB 1191 PC 396 506.71 TC 506.21 EP PROPOSED SPOT ELEVA7ON TBC DENOTES TOP/BACK OF CURB TAB DENOTES TOP OF BOX 506.71 Tw 506.21 ew PROPOSED SPOT ELEVATION TW DENOTES TOP OF WALL BW DENOTES BOTTOM OF WALL PRESERVED STEEP SLOPES MANAGED STEEP SLOPES PEDESTRIAN AND VEHICLE ACCESS PROPOSED CONCRETE PROPOSED & EXISTING GUARDRAIL PROPOSED FENCE 00 0 0 (0 100 YR. FLOODPLAIN OO Sheet List Table Sheet Number Sheet Title 1 COVER SHEET 2 EXISTING CONDITIONS 3 LAYOUT PLAN 4 UTILITY PLAN 5 GRADING AND DRAINAGE PLAN 6 NOTES AND DETAILS 6A NOTES AND DETAILS 7 NOTES AND DETAILS 8 ROAD & WATERLINE PROFILES 9 ROAD PROFILES 10 SANITARY SEWER PROFILES 11 STORM SEWER PROFILES 12 STORM SEWER PROFILES 13 DRAINAGE MAP AND CALCULATIONS 14 DRAINAGE CALCULATIONS 15 SIGHT DISTANCE PROFILES 16 LANDSCAPING PLAN 17 TOTAL NUMBER OF SHEETS SCOTT/R. CtTLLINS7_ Lic. No. 035791,E p` S 6/17/21 404' o�S'rONAL E��'Z Vl Z Z O J Q i z W ' g o I O w 0 m U) J Q 1 z O Q P w Q i n z w W C 5 Ce �J C'4 IN N %0 ti ti N i W N CD N WN z LU .J .J U) inU7 z LU W e C/) \.J 0 O O N AN F- w F w w x a Ln JOB NO. 112066 SCALE 1"=50' SHEET NO. 1 71 V -- - v \ \\ I \ 10II PZ / V A I N 1 _/ A AV A V III VA V A\ F, A V \ \ V A \ I I I 1 I I / I I v;� I I I I I' � V A\ I I I I I I I I , ✓ / I I/ I I I I � I 1 I I 1 1 A \ \ IIII IIII I A � V A\V A/ 1 \ \ A A \ V A I \ I -7 F, A\ vAVA \ > v v vvv I v v I I I I > w w Z o 0 a 0 0 u U U u ED L Z \ / F1 W Q o z z / i o 0 0 0 0 F J J \ III �• VI\II� / / / \< /' / j W � ..wmmm I / cc a a I/ / /l / - � � w I TMPI90F6 / A BUILDING IESCRIPTI INS // / / / /�" / / / / / / o a Lu / v v �LAIL80�I SANITARYSE-1, I / / - w NSF DANEIL � � / / / / � / / / / / trzo'GRADING ^ I — DB. 3zg SPG.607 SHUMATE- '-' '-'v 2 STOR VINY / / / / / / � Ln EASEMENT i EXISTIN 8' � V I\ BRInHOUSE �N BHJEM ENT / r A ' i DB \ / X / X X \ DB. 3zga PG. 607 / E/P EI zo'GRADING _ I \ 091 PG 534 1 EASEMENT 1 / r ' �e92 De. 3�g� PG. 60, � 1 � \ - B. 24 �x24 CONCRETE SLAB / EXISTING z x \ \ /c \ TMP 90E-7 COMMUNITY C. 2 x32 CONCRETE SLAB TMP 90-32A \ ASCA i� p, v / A ti m TMP 90E-9 TMP 90E-8 1 \ NIP IAN FARIS ASSOCIATION INC CIO , , / / / I )A2 0.'`"N 1VDB 4163 PC 261 REAL PROPERTY INC D. 20XZU 1 STORY VINi�F ��' i�B�''i�T SP1i LSNNORLIVING /F IGNACIO 0 DB 3692 PC 319 / TRUsr TARA L DE BUILDING ON BASEMENTS / / DB 982- PG 365DAB 5116 PG 289 I CARDENASTMP 90E-A TMP DB 4060 PG 77 II I II II I 1 NYF ALBEMARLE COUNTY F, F. w i I NSF AVON PARK a m I I SERVICE AUTHORITY X A \ I W r t- DB 3571 PC 272 I , / / w I v / / O —� OVEN WIRE v i, / / / / / / / m � yo6 O� a �9 6�8 b��� 6l° �rb66' i / / O N `D / / o io° �o° c1� oi�O m rn / / / / / w n� n n \ o �� 5 °48'0T E 485. 8' / I / O m ry / / / / -' �5 h h h°I / / / / F ri ri m m 96 F �� III //�I°�6�'6�'y5�oh� h �° a O m� 55848'09"E 14.92' � ) PF 31°I2'0 W 3��10'A / / / / / i — IF P X— _—_— A A� I i51"E 37 .�' -' / / / BE N29'06'41"E 9.00' v v X— X— X— —_ V ) - — ° / / / / zoo' x X x-A— X - w\ vv vv vv / I I I I � 1 �I PROPERTY WOVEN WIRE LIMITS,TYP. \ \ \ I I I FENCE I _ FENCE UTILITY EXIST�NG 1 1 I I I I I I I ( I \I ✓ I 1 \ �� _ \ 24 CMP L9 20 ?NTH TO B�REMOVED DB.424'2I 1 I I I /y V \ / \ \ DB.423 PG.5IPi V / X __-- / / A DB.3561 PG.464 \ z f� V/ A - �� 1 TMP 90-31 �/ I I v M \ \ \ 5.262 AC \ V \ N EXISTING KENNEL I , I I I EXISTING NG FENCE 229 A V21A1 SF � \ \ � \ IIV B. 10,AX2 ' BRA NAGE EASEME vVT TO BE REMOVED TOBEREMOVED 4PG.462 EXI$TINiWELL V \ 1 D G.572 / YORE AI CONCRETE 1 BRICK WALL V 1 V V A V �ATo BE v CA `S� ✓"� \ A I �I \ V v v \ v pro 1 I o� v KENNEL v y A \ v z�. ro \ \ i I I 1 \ v ASPHALT � G I e cs` � �, / 11 I v / CONCRETE ~� \FAI , EXISTING HOME TO REMAIN 1 ) /\ �`, ON CR�` TE \ \ \ 0Is V / o CID o ". h � V if1 Vl GRAVEL A s 'D ^ \ It0.7' WOVEN, �. - - - / IF iN MON I x �1 ° ��' PLANTER 1l 1 E IN oN WIRE FENCE OVER ON LINEv ° 028 Plo PROPERTY LIN \ v v / ) TP \ / \ I o V A \ I V A \ \ I � L 6 v � oo ao �o n aooa o ro to ry o m q<o a o eo m m m ro ry iO 69Ow - to ko � � 9 FcP � I / TMP 90-30 WOVEN WIRE / V ANIF CARY D BROOKS JR — — —F- N� O // / ±0.3 WOVEN I I I I I / // // / dV�F JOHA7 A OR RUTAIP BY BROOKS 1 TDB 4858 PC 406 PERT / // A WIRE FENCE OVER 1 � � �/ � / / I TMP 90-30A I I I I I l DB 1191 PC 39s PROPERTY E�E NTF CARY D OR MYRTLE BROOKS — / / DB 1191 PC 396 — — / /� 1 1 EXISTING MANAGED STEEP LOPES // // GRAPHIC'SCA/YE /40 / / 20 /' 4a s 1N F ET / ,/1 inch 40 f Lic. No. 035791,'n 6/17/214J W N 0 rn (N w N w J \\J U) I n D C. zLu W U) Am [110 w a En JOB NO. 112066 SCALE III = 40' SHEET NO. 2 M. LOT AREA TABULATION LOT NUMBER LOTAREA(SF) BUILDABLEAREA 1 2448 1405 2 1151 911 3 1152 912 4 2169 1427 5 2007 1303 6 1566 1237 7 1568 1237 8 2050 1338 9 1971 1273 10 1541 1211 11 1535 1205 12 1994 1292 13 2509 1713 14 1226 986 15 1226 986 16 2414 1659 17 2301 1567 18 1681 1351 19 1681 1351 20 1222 982 21 1679 1350 22 2297 1560 23 2141 1408 24 1549 1219 25 1130 889 26 1559 1225 27 1 1559 1 1229 28 1 2134 1 1427 NOTE: 1. ALL WATERLINES, SEWER LINES, AND FIRE LINES FROM THE MAIN TO THE STRUCTURE MUST HAVE A VISUAL INSPECTION PERFORMED BY THE BUILDING DEPARTMENT. 2. WHERE THE FLOOD LEVEL RIIMS OF PLUMBING FIXTURES ARE BELOW THE ELEVATION OF THE MANHOLE COVER OF THE NEXT UPSTREAM MANHOLE IN THE PUBLIC SEWER, THE FIXTURE SHALL BE PROTECTED BY A BACKWATER VALVE INSTALLED IN THE BUILDING DRAIN, BRANCH OF THE BUILDING DRAIN OR HORIZONTAL BRANCH SERVING SUCH FIXTURES. PLUMBING FIXTURES HAVING FLOOD LEVEL RIMS ABOVE THE ELEVATION OF THE MANHOLE COVER OF THE NEXT UPSTREAM MANHOLE IN THE PUBLIC SEWER SHALL NO DISCHARGE THROUGH A BACKWATER VALVE. NOTE: ALL LANDSCAPING EASEMENTS, BUFFERS, AN SCR ENING SHALL E PLANTED IN ACCORDANCE WITH THE APPROV D PROFFERS LANDS APING SHALL BE INSTALLED PRIOR TO THE FIRS CER IFICAT F OCCUPANCY FOR ANY PROPOSED UNITS WIT IN T E DEVELOPMENT AS DETAILED IN PROFFER PROPOSED 2o' DRAINAGE AND LANDSCAPING EASEMENT (LANDSCAPED BUFFER AREA) AREA PROPOSED ONSITE LANDSCAPE BUFFER 2o' GRADING NOTE: IF TREES RE LOCATED WITHIN 5' OR LESS QFTHE PROPERTY EASEMENT E ISiING 8' , /P E/ I2' DB.3zga PG.607 LINES ADJACEN TO T�PgoF-Az, TMPgoF�yz; TNiRg�F-43�, R TMPgoF-F-44, T E DEVELOPER SHALL REMOVE THE TREES ON THE I � XISTING ADJACENT PRO ERTIES: THE REMOVAL OF S WILL BE C\t � o, SUBJECT TO TH EXISTING PROPERTY OW ER'S WRI N APPROVAL. co m v CO F/C - F/C ACSA PROPOSED �I 0. W > 0 000 LANDSCAPING WITHIN 15' WATER SCRIM FENCE FENCEN o w 4 00 0. v E` Cl) n I w LANDSCAPE BUFFER THAT TANK q ONG W L' E' Z Lu LLJ Z - ABUTS ACSA WATER TANK _ ! TMP -A2 PROPERTY F 0. PROPERTY SHALL HAVE NIF ALBEMARLE COUNTY LINE ~Ln SIMILAR LANDSCAPING TO SERVICE AUTHORITY 2 c o WHAT WAS PLANTED WITH Dp; 3571 PC 277 � 1- T THE LATEST AVON PARK STORAGE TANK SECURITY PROPOSED 15' LANDSCAPING 0. EASEMENT (LANDSCAPED PROPO�io' Z o FENCE IMPROVEMENTS BUFFER AREA) LANDSCAPE PROPOSED DB. PG. EASEMENT CG-2 CURB DB._PG._00 - Ln - SETBACK LNO PARKING � „ I SIGN .) SETBACK 60. ' f-241 EA SET K5'REAR LOTN18 TTI I /P E/P IIEI5 RAVE WAY PARKING + — a I LOT LOT LOT LO_ 32' N " 4 *3 * 2 1 F/C F/C N LOT - N — I N � 6 - N I 1' Er III " h — N NO PARKING k W I LOT - SIGN (TYPA PROPOSED q 7 - O CG-12 (TYP- - - - - - 10 s6 16' 34' C) ago q 1 LOT N s s� �y 0. $ .p f 1. f, ':.'r k . ,. I . I �. i. + ti Ev R 2 - S' CONRETE� w SIDE SETBACK 71' SIDEWALK DESOTO DRIVE w_- °ry w_ E'4 `*, � b I -- '(TYP.) — — — a 49 PRIVATE RIW w N la Ii J 2 W V MAILBOX LOT °N° KIOSK o U 5� ti� °. Ev h v 0. 0 j , - 0 - +^ 32 16 1 2% 2 NO PARKING i '. RONT S TBA N LOT , SIGN (TYP.) PROPOSED PRIVATE ACCESS EASEMENT 10 j 70 - - STREET SIGN (TYP.) p 2 DB. PG. LOT ry p tie oe- — �° k 70, o LOT LOT LOT LOTI 5' REAR SETBACK - 3 14 15 16 J p y LOT N 2yl �a * * - rZ 0 TRAVE WAY PARKING 12 + L----1'REAR ETBAC -- - -- -- -- - + k STREET TREE OPEN SPACE NO PARKIN (TYP.) AREA A: 7,334 SF SIGN (TYP. PROPOSED io' LANDSCAPING PROPOSED DOUBLE -SIDED EASEMENT (LANDSCAPED TMP 90-30 VERTICAL FENCING (BOARD BUFFER AREA) ON BOARD) PRIVACY FENCE DB. N/F CARY D BROOKS JR PROPOSEDzo'LANDSCAPINGEASEMENT- NATURAL VIA- LANDSCAPED AREA OR REPLANTING/NEW LANDSCAPED BUFFER FOR ANY DISTURBED AREAS DB.PG. 1 m 200 1 m S - ---- - - N --- PROPOSED 20' S I EMERGENCYACCESS \ - - - - EASEMENT / CONCRETE LOT 30 37,445— o.86 ACRES ASPHALT Q ( CONC ETE ( O NOTE: SCRIM FENCING TO BE INSTALLED IMMEDIATELY FOLLOWING GRADING IN THE LOCATION WHERE THE SCRIM FENCE IS TO BE LOCATED. MILLING AND OVERLAY FORIMPROVED ASPHALT DRIVEWAY PROVED ASPHALT DRIVEWAY ACCESS FOR (2) LOTS /N •♦ ✓ l� O - -- '_ cc PLANTER I 2o' GRADING I EASEMENT D DB.3291 PG.607 I I TMP 90E-7 --- ♦ �O \X I TMP 90E-9 N/F IAN FARIS _ �� �i CP O'CONNOR LIVING TMP 90E-8 DB 4163 PG 261 ♦� O Lic. No. 035791,E 6/17/21 40i Z 0¢ k z w E ou i c - F O U w m E En Q w z O < F- a L `H v) z w / > ° to w i �W/ cc Ii ; CD N N •--� `"", C) .�-I n .\I N N to LANDSCAPED BUFFER FOR ANY N Q DISTURBED AREAS / �� - 1� W DB.PG. - - J OPEN SPACE 5.262 AC z AREA B 229,211 SF�' W Q 50,515 SF /7 -� EXISTING GRAVEL — �— DRIVEWAY TO BE CONCRET O F _ CG-12 (TYP.) i BRICK WA IMPROVED TO AN ' ' 4. j 6j d PROPOSED 1 _ y ASPHALT DRIVEWAY I Q I� n u VDOT STDGUARDRAIL AND 30TO LOTS zg I LOT 30 = I --I DESOTO DRIVE o W-� S PROPOSED LOT 29 3 37,445 0 N p- N �j CG-6 CURB GR 2 I NOTE: SLOPE OF 40,020 SF I I o.86 ACRES ci 49' PRIVATE RIW w S EMERGENCYACCESS 0.92ACRES I r •I r 2s ROAD SHALL NOT I j I Y o + EXCEED 16% I I LLI Q PROPOSED 1 CONCRETE PROPOSED 20' I 1 ~ a- 30, _220'. RON 22 A 6' 12, 22 O' CG-2CURB II l A EMERGENCYACCESS I 7 (MIN. - - I EASEMENT / U) Z YF I I I _ #1968 DB. PG. �/ ► Q m r k TR V oLWAY PARKING 1 1 PROPOSED 22' / 7 1011 ETE LLI > �7 A ASPHALT EMERGENCY i 7 LLJ Q o \ \ ACCESS ROAD LOT LOT LOT LOT LOT LOT 2z — — — — — — �- 0 17 1$ 19 9c 20 21 J + 1 PROPOSED47 PRIVATE , \ - - �— - — = _ _ GRAVEL I 00 I - JI I + ACCESS EASEMENT - - _ - - - - - - - I j L _ DB.PG. \ _--------- 2o'REAR ETBAC - - - - - - - PROPOSED CG-6 CURB Of N PARKING G lid SIGN (TYP.) N59°18'07"W 1,072.99'(T) C ) G PROPOSED io' LANDSCC APING O CV EASEMENT (LANDSCAPED -- - BUFFER AREA) TRUST N/F IGNACIO 0 �' DB 5116 PG 289 TARA L DE CARDENAS ` � �O Lu DB 4060 PG 77 TMP 90-308 - - - - - PROPOSED io' PROPOSED SCRIM FENCE A%IF JOMN A OR RUBr T BROOKS ♦ �� � � LANDSCAPING FENCE ALONG PROPERTY LINE DB 1199 PG 396 I EASEMENT ADJACENT TO TMP goF-Ai PROPOSED 5' M DB. PG. PROPOSED 2o' DRAINAGE AND LANDSCAPING COMMUNITY M LANDSCAPING EASEMENT EASEMENT ASSOCIATION INC CIO PROPOS ® Cn (LANDSCAPED BUFFER AREA) DB.PG. REAL PROPERTY INC y LANDSC DB.PG. DB 3692 PG 319 S58° 107' E 485 78' S31 °02'03"W 3.10' Z DB. M 011111111111111 S59°21'51"E 370.96' C PROPOSED . PROPOSED CG-z CURB 106 , m 200 l N NO PARKING zoo / CG-6 CURB i PROP SED EMERGENCY ACCESS O O SIGN TYP. � f SG ROAD REMOVABLEBOLLARDS r r 1 Cn ....:...... W' m q m N_ _ _ zo' R AR SET ACK_ _ - PROPOSED CG-9D� ---------1--- _ -�� -- I I + DRIVEWAY PROPOSED 2o' LANDSCAPING _ ENTRANCE EASEMENT - NATURAL LANDSCAPED _ Q 7 L08T LOT LOT LOT LOT LOT + AREA ORREPLANTING/NEW N 27 26 * �5 24 23 0 0 _0 --- a \ 1 °I 0 °1 °I � 12'xi8' ASPHALT \ j - DRIVEWAY( MIN.) io' FRONT SETBACK k v \ \ O \ .' STOP SIGN (TYP.y L J \\ _ a 1 30, 22' 22 1 ' 22 0' a PROPOSED DB 4000 PG 406 / LPROPOSED 3 BOARD FARM FENCE ALONG PROPERTY LINE NOTE: ALL STREETS WITHIN THE DEVELOPMENT SHALL BE MARKED WITH NO PARKING SIGNS ON BOTH SIDES OF THE ROADWAY. NOTE: (*) DENOTES THE LOCATI N OF THE AFFORDABLE UNIT WITHIN THE DEVELOPMENT. PEP PROFFER #i, THERE SHALL BE (6) AFFORDABLE HOUSING UNITS (THIN THE DEVELOPMENT. TMP 90-30A N/F CARY D OR MYRTLE T BROOKS DB 1191 PG 396 GRAPHIC SCALE ( IN FEET ) 1 inch = 30 ft. TMP 90-30B NIF" JOHN A OR RUBY T BROOKS DB 1191 PG 396 121 Lu O w W JOB NO. 112066 SCALE ill _301 SHEET NO. 3 x— x— X x ACSA WATER TANK f TMP -A2 N/F ALBEMARLE COUNTY SERVICE AUTHORITY B 3571 PC 272 --- X IF 1 � Y r \ m r- ♦m I = 24" CMP - F \11 \ LOT 30 37,445 --- --- o.86 ACRES I IMPROVED ASPHALT \ DRIVEWAY ACCESS FOR (2) LOT \ I I �D lb _REMOVE EXISTING 12" B.O.V. I AND TIE-IN TO EXISTING 12" DI WATERLINE 3 II I II � SANITARY SEWER / EASEMENT I II" DB. 3291 PG. 607 -_ I x � TMP 90E-7 --------------------- � COM TMP 90E-9 N F IAN FARIS rcr I TMP 90E-8 >. O'CONNOR LIVING DB 4163 PG 261 -- F` `v I TRUST N/F IGNACIO 0 x N m w 0. �� 1 I TARA L DE �I i DB 5116 PG 289 CARDENAS h 4, a 4 DB 4060 PC 77 q o W h I PROPOSED 2o' / x 2 OR �h b SANITARY SEWER v I I I EASEMENT m q i A�;SOUIATJIJN INC CIO REAL PROPERTY INC NOTE: ALL TH UNITS SHALL HAVE ROOF PROPOSEDTYPEA z I DB 3692 PG 319 DRAIN SYSTEMS THAT WILL COLLECT THE RUN-OFF AND CHANNEL IT FROM THE ROOFS BLOW OFF ASSEMBLY LOCATION OF SANITARY y ROPOSED 8" SANITARY SEWER (TYP.) pp TO THE PROPOSED DRAINAGE SYSTEM. TI -IN CONNECTION 48'07 485 --S31°02'03"W 3.10' NOTE: INDIVIDUAL PRIVATE DOMESTIC WATER BOOSTER PUMPS SHALL BE PROVIDED IN EACH HOME TO MEET THE MINIMUM WATER PRESSURE REQUIREMENTS. NOTE: PROPOSED STORM SEWER SHOWN IS CLASS III RCP. THE CONTRACTOR MAY SELECT A VDOT APPROVED MATERIAL IN LIEU OF THE CL. III RCP FROM THEIR APPROVED LIST PROVIDED ALL PIPE, PIPE BEDDING, BACKFILL AND INSTALLATIONS ARE IN ACCORDANCE WITH THE CURRENT VDOT STANDARDS. ANY PIPE MATERIAL PROPOSED AS CL. IV RCP SHALL NOT BE SUBSTITUTED WITH ANOTHER PIPE MATERIAL. II II LOT I I 5 h- 4 PROPOSED 6" DI WATERLINE (TYP.) `�i j LOTIL I o-- - - - L' I LOT 4,:� L 1 7 qo I 11 I 1 � h I w U I LOT co I 8 PTROPOSED 6"X6" TEE - O o o (2) 6" G.V.7- E, W � C w o LOT 0 9 \o 2 I ! I LOT '• ' I 10 I PROPOSED WATER ------ SERVICE LATERAL (TYP.) -_- LOT _ 11 I 11 i II - I LOT IL ILL12FF i PROPOSED 20' PROPOSED 6" DI WATERLINE (TYP.) WATERLINE - T I I � __T - EASEMENT PROPOSED 12" DI WATERLINE (TYP.)-,I I I I ----II ----- LOT LOT LOT I LOT LOT L T LOT LOT --LOT w 4 * 3 * 2 LOT 28 27 2 * 25 �4 23 � PROPOSED SANITARY SEWER v� I SERVICE LATERAL (TYP.) I I I�- " ,�• � � �. � BRICK WI I DESOTO DRIVE TYP 90-31 5.262 AC 229,211 SF'� / OPEN SPACE DESOTO DRIVE F LOT 29 49' PRIVATE R/W - - - - 49`PRIVATE R71 - - I 0, o.92 I jr r FAMI CONCRETE I + , f A. F I I AUCET i I I 1 - I I II I I I l #1968 / I --I --I o \ PROPOSED20' TRAFFIC RATED PROPOSED 6" 90 BEND ROPOSED 8" SA ITARY SEWER (TYP.) I 1 PUBLIC UTILITY f� METER BOXES EASEMENT LOT LO LOT LOT LOT LOT LOT LOT LOT LOT 1 1 20 22 -- 3-- 9c n 17 --i8-- 19 4- 21 ----- PROPOSED TYPE A \ _ - - GRAVEL I I I I I BLOW OFF ASSEMBLY - �— - I IF IN MON -I -I --I I- - I -- LINE 0.28 @ - ' --- - -- - ----- -L--- TP I OPEN SPACE PROPOSED i2"X6" CROSS F ., .. (1) 12" G.V. PROPOSED (2) 6" G.V. PROPOSED TYPE A VARYING WIDTH BLOW OFF ASSEMBLY PUBLIC UTILITY PROPOSED 12' DI = "/---WATERLINE �5 PROPOSED EASEMENT WATERLINE EXTENSION �- EASEMENT PUBLIC U EASEMENT WITHIN THE PUBLIC R/W i TO THE PROPERTY L� TMP 90-30 N/F CARY D BROOKS JR DB 4858 PC 406 NOTE: ALL PUBLIC WATER AND SEWER FACILITIES SHALL BE DEDICATED TO THE ALBERMARLE COUNTY SERVICE AUTHORITY PROPOSED TYPE A BLOW OFF ASSEMBLY NOTE: ALL PUBLIC WATERLINE EASEMENTS SHALL BE PLATTED PRIOR TO FINAL SITE PLAN APPROVAL N59°18'07"W 1,072.99'(T) TMP 90-30A N/F CARY D OR MYRTLE T BROOKS DB 1191 PC 396 Lic. No. 035791,E 6/17/21 40i ,w \/1 Z O ¢ k F F- w E o i c - F O U w m En e En Q H Z O .Q 1~ w Q L v) Z W > ° V) > f ` �W/ cc Ii o , , W N N N 1-0 o O\l to Lu Z � ti M co 1 v N ♦ n co r � m N CD ♦ m �m N - - I---- = I N ♦m � ♦m _ LJ LJ � � J (n Q z L9Lu O O j:j� Q CONCRET _J 1 I LOT 30 = ~ 37,445SFU J o.86 ACRES W F--Lu . m� z 1 j CON C ET E w O w a z I � ! r� U I CD00 ~ 1Lu I O O CD N TMP 90-30B NIF ,JOHN A OR RUBY T BROOKS p w DB 1191 PG' 396 a GRAPHIC SCALE JOB NO. 112066 30 60 121 SCALE 111 _ 301 ( IN FEET ) SHEET NO. 1 inch - 30 ft. 4 TH 0 4 10�� SCOTT R. LINS�Z VARIABLE WIDTH SWM FACILITY Lic. No. 035791 \ I ACCESS EASEMENT 6/17/21 c4 DB.PG. I ✓ I / I III / / / / �SSIONAL Eck I I I V I I �1 -" s'/ � _ r�' -- �• ��tZP�l �3A- 2�� I � VE 24 PROPOSED ROPOSED i�RIPPR AP OUT OUTFALL INTO ROADSIDE DITCH MP 2 E 0 OVED ASPHALT / \ A z DRIVEWAY Lu w w o 0 SWM z \ I - ��.. ACCESS FOR (z) LOTS \ 0 a a in F Lnn Lnn z J f O E � w w w "� �\ \�� Z O a��� z vim- u a o 0 \ m / 37,4530 _ \ \ 0 m En z o.86 ACRES \ Z Q w w V U Cs �. 0 Z o a I \ I I I �� �/ A �� v v� v v� / / AI Lu Of a [a Lu a Lu I I \ 11 \ \ \ \ \ \ w w \ w w - 00 r • A \ a O + -- - zo' GRADING i0 �- � I zo' GRADING / \ EASEMENT -EASEMENT / 0 0 \ / X / X xA DB. 3291 PG.607 I I I x\ \ x CO II II A \ C23-o 7� rn xw'ra I I TMP 90E-A2 h \% 0. sq s1 N/F ALBEMARLE COUNTY 2 SERVICE AUTHORITY x I I II DB 3571 XG 272 PROPOSED 8" HDPE ROOF �I \ DRAIN SYSTEM W/ 1o' PRIVATE 6 W o N G 11, DRAINAGE EASEMENT 96 a 6 D 9� 96 DB. PG. TIN 690 TW 690 TIN 6 '� "C 114.92' 690 BW 688 Bw 6 TIN 688 BW 6811 Bw 68 ---- -- - -- -- � I � L___ � I- - I ram-- --- I TW - _--- y I 1 LOT 690 AR=6g1.83 BW 1 '� - - - 687 1 6687- I FE 6gz.49 L.. LOT 1 \ TW 690 --- I LOT LOT LOT W 68 LOTFFE \ .I 4 7 G ER68 .17 -, FFE=1O7�T I d 5 , GG�b8683 1 1 r GA�R8.1 ! 3 6 6g 8g 6% 1IFFE=688.83 1 6.8 `1 - E, 1 11 GAR-8 FFE=6150 1 1 N LOT +v I 2 m 7 AR=69o.50 3oA 2, r FE-6g1.17 I: o �Y7\ -- 1 o) BW 689 LOTGAR=68g.83 zoo ' .. C : 20' PRIVA o v $ FFE=69o.5o 1 -o DRAINAG a I \,DESOTO DRIVE I I E:� TW sas =I_ r r - - 4� �RXATE _RIW BW 68 o LOT 9 _ - p _ I AR=68g.17 z% V U I I FE=6go.83- rs,o 2 il✓�00 ` LOT AR=68g.17 20 .,-j \ ^�� I 10 FE'=6go.83 POSED 8" I GAR=6 0o GAR HDPE=6 5.501 I ROOF DRAIN l 12 1�JR6 FFE=6 7. 7 FFE=68 .17 1 SYSTEM W/ 1o' ,. 7. 371 1 0 AR=6 33 LOT FFE=6 7. o PRIVATE 11 AR=689.17 DRAINAGE FE-6go.83 LOT LOT EASEMENT --- - ' iI LOT 1 LOT i6 --- 4 1 PG. �- * * ------ 1 DB. I TW 687 1 1 AIR .8 4�/o J1 I I LOT j 12 9 3 + r 'I BW 8 --- FE=691.49 1' _ 1I I - ----- -� 1 TW 6� ---- f i I BW64 - - -- ----- OPE IF PROPOSED 8" 1 6 6 HDPE ROOF DRAIN O / 0 6 9 � � 86 8 o SYSTEM W/ 10' PRIVATE DRAINAGE 690 \ -EASEMENT \ \ \ TMP 90-30 �-, DB.PG. - - � N/F GARY D BROOKS JR / I DB 4858 PC 406 LLLrLLLd XISTING MANAGED STEEP SLOPES TO REMAIN / I I � NOTE: ALL PUBLIC WATER AND SEWER FACILITIES SHALL BE DEDICATED TO I THE ALBERMARLE COUNTY SERVICE I I II AUTHORITY I I i DB. 3zg1 PG.6o7 \ V 1 \ I / w CD rj ^' ^' ni ni o Zir TMP 90E-7 TMP 90F 9 N/ F IAN FARIS - I 1 / - ♦ / 0 TMP 90E-8 CONNOR LIVING I TRUST I N/F IGNACIO 0 1 TDB 4163 PG 261 DB 5116 PG 289 TARA L DE � I CARDENAS � / / l � � � � L9 � � I DB 4060 Pc 77 I PROPOSED 8" HDPE ROOF DRAIN SYSTEM W/ io' PRIVATE DRAINAGE EASEMENT (+) 1 �\ pg. pG. i / / / to I FL TH UNITS SHALL HAVE ROOF / ° yob you 0 d cb o / REAL PROPERTY INCD o M ya, yy t}' � �/ DB 3692 PG 319 /0 5 m STEMS THAT WILL COLLECTTHE / h sg y yy yyv yyo yy� 00 I P� ROPOSED DRAINAGEFF AND CHANNEL IT HEE ROOFS ��� VARIABLE WIDTH D SWM FACILITY M 0h coh In ° - I I / 4 / i'ACCESS EASEMENT 48'07'-�485.78�� 16 I �531°02'03'Vd 3.n0' / �o° E 779.96� 3 3B CD 1 --- 3A 3C m 3D 4 -- - - --- +---_=-� - - ---- - - - - -------- -- - - ------------- - - - - -----------T_ - 2 - N N � ---- - - _ �nI- z LOT LOT LOT *L25 OT LOT LOT o j �- m _�<. 28 2 z6 II 24 z3 1 � ti � r---------------------------------------- - - s9-- - - �, GAR 8z.00 GAR-681. IIGAR-68o GAR -6 8.6 1 I 4A o b1 - - - = - LLI Q 1 7 .6 331 - 7 1FFE�6 7 1 - ------ 23 FIFE 68 FFE=68zoo II - 9i 7 33 1 I y�o I GAR-6 331 I ------ l I,//1 90 �> 1 i LV GAR 68z33 FFE=68, 7 I FFE=6 .?ol 1�1 11� I I ��. `n , zo' PUBLIC .. I i � 2 3 � �.... � .-- , 1 -- � I II I I �' yya PROPOSED STORM `DRAINAGEESMT �11 �II � �J,J -- OUTFALL PIPE DB. PG. I SWM 2 Lu Q o � O - -bbb OPEN SPACE 6O4 L9 z 18 RI K W 22 606_ ��NCQET J Q I A 5 \ V A \ \� I Q i--i T-- I VARIABLE \ \ \ 6o8 \ LOT 30 1--I DESOTO DR E --- --J m WIDTH SWM 9 \ ' \ 37,445 _ LOT 2 \ ° FACILITY 06 40,020 SF V A - _ 49 PRI ATE W ----- 61o' \ o.86ACRES ci o � I ACCESS � o.9z ACRES Y L - EASEMENT PG I \ j 61z `. \ LLI Q Z CONCRETE 10' PRIVATE \ v � DRAINAGE 6zq � v 21 \ A. EASEMENT i -_-FT \ I � \� -i � 6 / � � \ � � � �9 l #1968 20 I -- �6 GONG TE Sg GAR=6 z.17 1 GAR= 8 .83 GAR=6j8.171 _ _ - - _ - - Es 4 FFE=68 .83 IFF =6 1 o FFE=67$.831 1 - -I _' _ - - j / A V LLI AGAR 683.50 GAR=6 1.5011 GAR-6 g.5o1 \ - ! 6�- IFFE 684.17 FFE=6 .17 I,i -J FFff=6 oa7 Imo! -- -- 17 ---- - -- \. n LOT LO f LOT I LOT LOT 11 a \ - - - _ - _ N o C _ D _ N Cn LOT 7 ---- 1 4'0 21 22 i _ � - -}-- �- _� . _ �_ M_ _�-'D o _ o:Jo GRAVEL O 1 _ 18 ko -- _ 00 - ��-- R W - I - I - a ,F IN MON I I� O 1 1F IN „l----=1 �- --- -- 0 ---' �- �-- @ 0.28' II -- -' o ou o N o co N�°18'0'W N1,07o.99�(T') - --- O iDiO �n �n It V1 t0 �t N O I - - O �6� W 00 04 0 O y ^ r!�� ,lam to l0 n N O O�D l�0 <O lD l0 t'- •- 1p l0 l0 l0 l0 �0 G lD �O �O 1p k0 t0 / / / PROPOSED 8" zo' DRAINAGE / / zo' PUBLIC X / I HDPE ROOF DRAIN I I I ESMT / DRAINAGE ESMT / / / SYSTEM W/10 DB.PG. �� / u DB.PG. / / PRIVATE zo' PUBLIC UTILITY / DRAINAGE ESMT ul�j I / / / / / / EASEMENT DB. PG. I I I / - / �/� // l 11 / / tu llN�"�HN AlOR�RUBY1T BR04S' O Lu / DB.PG. I / D� 1191 PG1396 / a m TMP 90-36A I I I I I / / N I I I I GRAPIC SCALE /JOB NO. NOTE: ALL PUBLIC WATERLINE //F GARY D OR MYRTLE � BROOKS H�E I � I I I � I / / 112066 206 EASEMENTS SHALL BE PLATTED PRIOR / DB 1191 PG' 396 I I I I I 30 0 0 30 / Bo / / 120 / I / / / / TO FINAL SITE PLAN APPROVAL / / � � I � � � I I I111 SCALE = 30' - IN FEET ) / / / I SHEET NO. , / / -----� I inch i 30 lift. / / / 5 GENERAL CONSTRUCTION NOTES FOR STREETS 1. CONSTRUCTION INSPECTION OF ALL PROPOSED ROADS WITHIN THE DEVELOPMENT WILL BE MADE BY THE COUNTY. THE CONTRACTOR MUST NOTIFY THE DEPARTMENT OF COMMUNITY DEVELOPMENT (296-5832) 48 HOURS IN ADVANCE OF THE START OF CONSTRUCTION. 2. UPON COMPLETION OF FINE GRADING AND PREPARATION OF THE ROADBED SUBGRADE, THE CONTRACTOR SHALL HAVE CBR TESTS PERFORMED ON THE SUBGRADE SOIL. THREE (3) COPIES OF THE TEST RESULTS SHALL BE SUBMITTED TO THE COUNTY. IF A SUBGRADE SOIL CBR OF 10 OR GREATER IS NOT OBTAINABLE A REVISED PAVEMENT DESIGN SHALL BE MADE BY THE DESIGN ENGINEER AND SUBMITTED WITH THE TEST RESULTS FOR APPROVAL. J. SURFACE DRAINAGE AND PIPE DISCHARGE MUST BE RETAINED WITHIN THE PUBLIC RIGHT-OF-WAY OR WITHIN EASEMENTS PRIOR TO ACCEPTANCE BY THE COUNTY. ALL DRAINAGE OU7FALL EASEMENTS ARE TO BE EXTENDED TO A BOUNDARY LINE OR A NATURAL WATERCOURSE. 4. GUARDRAIL LOCATIONS ARE APPROXIMATE. EXACT LENGTH LOCAT70N AND APPROPRIATE END TREATMENTS WILL BE FIELD VERIFIED AT THE TIME OF CONSTRUCTION. ADDITIONAL GUARDRAIL MAY BE REQUIRED AT LOCATIONS NOT SHOWN WHEN, IN THE OPINION OF THE COUNTY ENGINEER, OR DESIGNEE, IT IS DEEMED NECESSARY. WHEN GUARDRAIL IS REQUIRED, IT SHALL BE INSTALLED FOUR (4) FEET OFFSET FROM THE EDGE OF PAVEMENT TO THE FACE OF GUARDRAIL, AND ROADWAY SHOULDER WIDTHS SHALL BE INCREASED TO SEVEN (7) FEET 5. WHERE URBAN CROSS SECTIONS ARE INSTALLED ALL RESIDENTIAL DRIVEWAY ENTRANCES SHALL CONFORM TO VDOT CG-9(A B OR C) . 6. WHERE RURAL CROSS SECTIONS ARE INSTALLED, ALL RESIDENTIAL DRIVEWAY ENTRANCES SHALL CONFORM TO VOOT STANDARD PE-1. 7. COMPLIANCE WITH THE MINIMUM PAVEMENT WIDTH, SHOULDER WIDTH AND DITCH SECTIONS, AS SHOWN ON THE TYPICAL PAVEMENT SECTION DETAIL, SHALL BE STRICTLY ADHERED TO. 8. ROAD PLAN APPROVAL FOR SUBDIVISIONS IS SUBJECT TO FINAL SUBDIVISION PLAT VALIDATION. SHOULD THE FINAL PLAT FOR THIS PROJECT EXPIRE PRIOR TO SIGNING AND RECORDATION, THEN APPROVAL OF THESE PLANS SHALL BE NULL AND VOID. 9. ALL SIGNS OR OTHER REGULATORY DEVICES SHALL CONFORM WITH THE VIRGINIA MANUAL FOR UNIFORM TRAFFIC CONTROL DEVICES AND THE ALBEMARLE COUNTY ROAD NAMING AND PROPERTY NUMBERING ORDINANCE AND MANUAL. 10. TRAFFIC CONTROL OR OTHER REGULATORY SIGNS OR BARRICADES SHALL BE INSTALLED BY THE DEVELOPER WHEN, /N THE OPINION OF THE COUNTY ENGINEER, OR DESIGNEE, THEY ARE DEEMED NECESSARY IN ORDER TO PROVIDE SAFE AND CONVENIENT ACCESS. 11. THE SPEED LIMITS TO BE POSTED ON SPEED LIMIT SIGNS ARE 5 MPH BELOW THE DESIGN SPEED, OR AS DETERMINED BY VDOT FOR PUBLIC ROADS. 12. VOOT STANDARD CD-1 OR CD-2 CROSS -DRAINS UNDER TO BE INSTALLED UNDER THE SUBBASE MATERIAL AT ALL CUT AND FILL TRANS177ONS AND GRADE SAG POINTS AS SHOWN ON THE ROAD PROFILES. 13. A VIDEO CAMERA INSPECTION IS REQUIRED FOR ALL STORM SEWERS AND CULVERTS THAT ARE DEEMED INACCESSIBLE TO VDOT OR COUNTY INSPECT70NS 774E VIDEO INSPECTION SHALL BE CONDUCTED IN ACCORDANCE WITH VDOTS VIDEO CAMERA INSPECTION PROCEDURE AND WITH A VDOT OR COUNTY INSPECTOR PRESENT. ROAD NOTES GRADING; 1. THE LATEST EDITION OF THE ROAD & BRIDGE SPECIFICATIONS, THE ROAD & BRIDGE STANDARDS OF THE VIRGINIA DEPARTMENT OF TRANSPORTATION SPECIFICATIONS SHALL GOVERN THE MATERIAL AND CONSTRUCT70N METHODS OF THIS PROJECT. 2. WHERE UNSUITABLE MATERIAL IS ENCOUNTERED IN THE ROADWAY, IT SHALL BE REMOVED FROM THE ENTIRE ROAD RIGHT OF WAY WIDTH AND REPLACED WHERE NECESSARY WITH SUITABLE MATERIAL TO THE SATISFACTION OF THE ENGINEER. J. ALL GROWTH OF TREES AND VEGETATION SHALL BE CLEARED AND GRUBBED FOR THE EN77RE EASEMENT. OTHER TREES AND VEGETATION WHICH OBSTRUCT SIGHT DISTANCES AT ROAD INTERSECTIONS SHALL BE REMOVED. 4. ALL VEGETATION AND OVERBURDEN TO BE REMOVED FROM SHOULDER TO SHOULDER PRIOR TO THE CONSTRUCT70N OF THE SUBGRADE. DRAINAGE: 1. ALL PIPE CULVERTS, EXCEPT PRIVATE ENTRANCES, SHOWN HEREON ARE TO BE RCP WITH A MINIMUM COVER OF ONE (1) FOOT 2. STANDARD UNDERDRAINS (CD-1 OR CD-2 OR UD-4'S) TO BE PROVIDED AS INDICATED ON 77-IE PLANS, OR WHERE FIELD CONDIT70NS INDICATE J. ALL DRIVEWAY ENTRANCE PIPES SHALL BE A MINIMUM OF TWENTY (20) FEET IN LENGTH AND HAVE A MINIMUM DIAMETER OF FIFTEEN (15) INCHES AND SHALL BE PLACED IN ACCORDANCE WITH THE VIRGINIA DEPARTMENT OF TRANSPORTAION SPECIFICATIONS UNLESS OTHERWISE NOTED ON PLANS 4. ALL DRAINAGE EASEMENT SHALL BE CLEARED AND GRADED TO THE SA7SFACTION OF THE ENGINEER. DRAINAGE EASEMENTS SHALL EXTEND TO A POINT DEEMED AS NATURAL WATER COURSE. PA VEMEN T.- 1. AN ACTUAL COPY OF THE CBR REPORT IS TO BE SUBMITTED PRIOR TO THE PLACEMENT OF THE AGGREGATE BASE MATERIAL. IF THE SSV VALUES ARE LESS THAN 10, THE DEVELOPER WILL BE REQUIRED TO SUBMIT FOR ENGINEERS APPROVAL THE PROPOSED METHOD OF CORRECTION. 2. SUBGRADE MUST BE APPROVED BY THE ENGINEER FOR GRADE, TEMPLATE AND COMPACTION BEFORE BASE IS PLACED. 3. TEST REPORTS ON SELECT MATERIALS MUST BE SUBMITTED SHOWING THE MATERIAL MEETS REQUIRED GRADAT70N FOR TYPE 1, II, OR Ill PRIOR TO PLACING AGGREGATE BASE. 4. THE REQUIREMENTS TO PUGMILL AGGREGATE BASE WILL BE WAIVED IN THE EVENT THAT THE SURFACE COURSE IS BEGINNING AT THE COMPLETION OF THE INSTALLATION OF THE AGGREGATE BASE. IN THE EVENT THAT THE SURFACE COURSE IS APPLIED PRIOR TO 60 DAYS, THE PUGMILL REQUIREMENT WILL APPLY. TYPICAL ROAD SECTIONS NTT NOTES: 1. SEE PAVEMENT DESIGN CHART ON THIS SHEET FOR ROADWAY DEPTH REQUIREMENTS. 2. STREET WIDTHS SHALL BE IN ACCORDANCE WITH ALBEMARLE COUNTY AND FIRE AND RESCUE STANDARDS & WILL PROVIDE ADEQUATE WIDTHS. GVRe EXIST. GROUND far PUNTING si GUTTER MAWtWAY EM�CA MST GROW EMsr. c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ll. 9. ALL EXCAVATION FOR UNDERGROUND PIPE INSTALLA77ON MUST COMPLY WITH OSHA STANDARDS FOR THE CONSTRUCTION INDUSTRY (29 CFR PART 1926). NOTE: MANDATORY INSPECTIONS AT THE FOLLOWING PHASES ARE REQUIRED FOR ROADS THAT ARE PROPOSED TO BE STATE MAINTAINED: i. INSTALLATION OF ANY ENCLOSED DRAINAGE SYSTEM BEFORE IT IS COVERED. ii. INSTALLATION OF ANY ENCLOSED UTILITY PLACEMENTS WITHIN THE RIGHT-OF-WAY BEFORE BEING COVERED. iii. CONSTRUCTION OF THE CUTS AND FILLS, INCLUDING FIELD DENSITY TESTS, BEFORE PLACEMENT OF ROADBED BASE MATERIALS. iv. A FINAL PAVEMENT DESIGN, BASED ON ACTUAL SOIL CHARACTERISTICS AND CERTIFIED TESTS, SHALL BE COMPLETED AND APPROVED BEFORE THE PAVEMENT STRUCTURE IS PLACED. v. PLACEMENT OF BASE MATERIALS, INCLUDING STONE DEPTHS, CONSISTENT WITH THE APPROVED PAVEMENT DESIGN, PRIOR TO PLACEMENT OF THE PAVING COURSE OR COURSES, FOLLOWED BY FIELD DENSITY AND MOISTURE TESTS AND THE PLACEMENT OF A PAVING COURSE AS SOON AS POSSIBLE. vi. CONSTRUCTION OF PAVEMENT, INCLUDING DEPTH AND DENSITY, UPON COMPLETION AS PART OF THE FINAL INSPECTION. vii. THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING VDOTA MINIMUM OF ONE WEEK PRIOR TO EACH OF THE ABOVE PHASES OF CONSTRUCTION TO SCHEDULE AN INSPECTION. viii. FAILURE OF THE CONTRACTOR TO SCHEDULE THESE INSPECTIONS WILL REQUIRE ADDITIONAL TESTING OF THE ROADS AT THE DISCRETION OF VDOT OR MAY LEAD TO THE ROADS NOT BEING ELIGIBLE FOR STATE MAINTENANCE. TYPICAL PUBLIC HATHA4WAY STREET S rTION KITH FARMING ON ONE SIDE (55.5' #,IDTfl ROR) 25 MPH DESIGN SPEED NOT TO SCALE TYPICAL PRIMATE DESOTO DRIVE STREET SffrTION WITH NO PARKING (49' WIDTH ROW] 25 MPH DESIGN SPEED NOT TO SCALE i 5' 5' TYPICAL PRIMATE ANOKO COURT SECTION WITH PERPENDICULAR PARKING (55.5' WIDTH ROW) 25 MPH DESIGN SPEED NOT TO SCALE 1 j " SM-9.5A SURFACE COURSE 3" BM-25 INTERMEDIATE COURSE • 6" COMPACTED AGGREGATE° ° Pg�'o�o°= dJ• O°j BASE COURSE, VDOT #21A OR 21B DEPENDING ON ULTIMATE TRAFFIC LIMITS ���N VE�� z AND UNDERDRAINS % �O COMPACTED SUBGRADE ASPHALT PAVING - ROADS NO SCALE PROPOSED 1" SM-9.5 OVERLAY EXISTING PAVEMENT EX. STONE SUBBASE COMPACTED SUBGRADE �I111111111111111111111111111111111111111111111111111111111111 ��'11'1'11�1'11111111111111111 /C� ASPHALT PAVING - MILL/OVERLAY NO SCALE TRIP GENERATION SCALE: 1" = 200' TRIP GENERATION CALCULATIONS TRIP GENERATION BASED ON ITE TRIP GENERATION MANUAL (8TH EDITION) TOWNHOME UNITS - CODE 230 ANOKO CT & DESOTO DRIVE (WEST): 16 UNITS PROPOSED SECTION OF HATHAWAY ST.: 28 UNITS ADT: 94 VPD (47 ENTER/ 47 EXIT) ADT: 164 VPD (82 ENTER/ 82 EXIT) AM PEAK: 7 VPH (1 ENTER/ 6 EXIT) AM PEAK: 12 VPH (2 ENTER/ 10 EXIT) PM PEAK: 8 VPH (6 ENTER/ 2 EXIT) PM PEAK: 15 VPH (10 ENTER/ 5 EXIT) PRIVATE ROAD & DESOTO DRIVE (EAST): 12 UNITS ADT: 34 VPD (17 ENTER/ 17 EXIT) AM PEAK: 5 VPH (1 ENTER/ 4 EXIT) PM PEAK: 6 VPH (4 ENTER/ 2 EXIT) Pavement Design RF= 1.0 Location ADT HCV Design CBR SSV Dr Surface h a Base b a Sub -base h a Dp ADT Hathaway Street 164 5 214 4 4 9.39 SM-9.5 1.5 2.25 BM-25 2.5 2.15 21B 5 0.6 11.75 Desoto Drive, Private Road & Anoko Court 94 5 144 4 4 8.01 SM-9.5 1.5 2.25 BM-25 2.5 2.15 21A 5 0.6 11.75 Access Road- Asphak SM-9.5 0 2.25 BM-25 0 2.15 21A 8 0.6 4.80 _f-- j- EMST. GROUND EWE GIVOUND T. GROUND ES TYPICAL PRIMATE ROAD SECTION WITH PERPENDICULAR PARR'! - 47' PRIMATE ROAD (PRIVATE ACCESS EASEMENT) 25 MPH DESIGN SPEED NOT TO SCALE GI I 5' S STONE NE SUBBASE & S AALT SPHALT 7O'CDAT EM�OtOUNO EXIST GROUND 4r ASPHAI MAMMY TO' ALTESS EASSRNT TYPICAL ASPHALT EAlERGENCY ACCESS SAMON ,0RIPEIY.4Y SHALL HAKE A 29 S&PEREZFV.4TION TO THE EAST NOT TO SCALE EMST.. GROUND ;COTT/R. CIDLLINSZ Lic. No. 035791 L 6/17/21 ,�fj V/ Z NO SCALE PROPOSED 1" SM-9.5 OVERLAY EXISTING PAVEMENT EX. STONE SUBBASE COMPACTED SUBGRADE �I111111111111111111111111111111111111111111111111111111111111 ��'11'1'11�1'11111111111111111 /C� ASPHALT PAVING - MILL/OVERLAY NO SCALE TRIP GENERATION SCALE: 1" = 200' TRIP GENERATION CALCULATIONS TRIP GENERATION BASED ON ITE TRIP GENERATION MANUAL (8TH EDITION) TOWNHOME UNITS - CODE 230 ANOKO CT & DESOTO DRIVE (WEST): 16 UNITS PROPOSED SECTION OF HATHAWAY ST.: 28 UNITS ADT: 94 VPD (47 ENTER/ 47 EXIT) ADT: 164 VPD (82 ENTER/ 82 EXIT) AM PEAK: 7 VPH (1 ENTER/ 6 EXIT) AM PEAK: 12 VPH (2 ENTER/ 10 EXIT) PM PEAK: 8 VPH (6 ENTER/ 2 EXIT) PM PEAK: 15 VPH (10 ENTER/ 5 EXIT) PRIVATE ROAD & DESOTO DRIVE (EAST): 12 UNITS ADT: 34 VPD (17 ENTER/ 17 EXIT) AM PEAK: 5 VPH (1 ENTER/ 4 EXIT) PM PEAK: 6 VPH (4 ENTER/ 2 EXIT) Pavement Design RF= 1.0 Location ADT HCV Design CBR SSV Dr Surface h a Base b a Sub -base h a Dp ADT Hathaway Street 164 5 214 4 4 9.39 SM-9.5 1.5 2.25 BM-25 2.5 2.15 21B 5 0.6 11.75 Desoto Drive, Private Road & Anoko Court 94 5 144 4 4 8.01 SM-9.5 1.5 2.25 BM-25 2.5 2.15 21A 5 0.6 11.75 Access Road- Asphak SM-9.5 0 2.25 BM-25 0 2.15 21A 8 0.6 4.80 _f-- j- EMST. GROUND EWE GIVOUND T. GROUND ES TYPICAL PRIMATE ROAD SECTION WITH PERPENDICULAR PARR'! - 47' PRIMATE ROAD (PRIVATE ACCESS EASEMENT) 25 MPH DESIGN SPEED NOT TO SCALE GI I 5' S STONE NE SUBBASE & S AALT SPHALT 7O'CDAT EM�OtOUNO EXIST GROUND 4r ASPHAI MAMMY TO' ALTESS EASSRNT TYPICAL ASPHALT EAlERGENCY ACCESS SAMON ,0RIPEIY.4Y SHALL HAKE A 29 S&PEREZFV.4TION TO THE EAST NOT TO SCALE EMST.. GROUND ;COTT/R. CIDLLINSZ Lic. No. 035791 L 6/17/21 ,�fj V/ Z ASPHALT PAVING - MILL/OVERLAY NO SCALE TRIP GENERATION SCALE: 1" = 200' TRIP GENERATION CALCULATIONS TRIP GENERATION BASED ON ITE TRIP GENERATION MANUAL (8TH EDITION) TOWNHOME UNITS - CODE 230 ANOKO CT & DESOTO DRIVE (WEST): 16 UNITS PROPOSED SECTION OF HATHAWAY ST.: 28 UNITS ADT: 94 VPD (47 ENTER/ 47 EXIT) ADT: 164 VPD (82 ENTER/ 82 EXIT) AM PEAK: 7 VPH (1 ENTER/ 6 EXIT) AM PEAK: 12 VPH (2 ENTER/ 10 EXIT) PM PEAK: 8 VPH (6 ENTER/ 2 EXIT) PM PEAK: 15 VPH (10 ENTER/ 5 EXIT) PRIVATE ROAD & DESOTO DRIVE (EAST): 12 UNITS ADT: 34 VPD (17 ENTER/ 17 EXIT) AM PEAK: 5 VPH (1 ENTER/ 4 EXIT) PM PEAK: 6 VPH (4 ENTER/ 2 EXIT) Pavement Design RF= 1.0 Location ADT HCV Design CBR SSV Dr Surface h a Base b a Sub -base h a Dp ADT Hathaway Street 164 5 214 4 4 9.39 SM-9.5 1.5 2.25 BM-25 2.5 2.15 21B 5 0.6 11.75 Desoto Drive, Private Road & Anoko Court 94 5 144 4 4 8.01 SM-9.5 1.5 2.25 BM-25 2.5 2.15 21A 5 0.6 11.75 Access Road- Asphak SM-9.5 0 2.25 BM-25 0 2.15 21A 8 0.6 4.80 _f-- j- EMST. GROUND EWE GIVOUND T. GROUND ES TYPICAL PRIMATE ROAD SECTION WITH PERPENDICULAR PARR'! - 47' PRIMATE ROAD (PRIVATE ACCESS EASEMENT) 25 MPH DESIGN SPEED NOT TO SCALE GI I 5' S STONE NE SUBBASE & S AALT SPHALT 7O'CDAT EM�OtOUNO EXIST GROUND 4r ASPHAI MAMMY TO' ALTESS EASSRNT TYPICAL ASPHALT EAlERGENCY ACCESS SAMON ,0RIPEIY.4Y SHALL HAKE A 29 S&PEREZFV.4TION TO THE EAST NOT TO SCALE EMST.. GROUND ;COTT/R. CIDLLINSZ Lic. No. 035791 L 6/17/21 ,�fj V/ Z _f-- j- EMST. GROUND EWE GIVOUND T. GROUND ES TYPICAL PRIMATE ROAD SECTION WITH PERPENDICULAR PARR'! - 47' PRIMATE ROAD (PRIVATE ACCESS EASEMENT) 25 MPH DESIGN SPEED NOT TO SCALE GI I 5' S STONE NE SUBBASE & S AALT SPHALT 7O'CDAT EM�OtOUNO EXIST GROUND 4r ASPHAI MAMMY TO' ALTESS EASSRNT TYPICAL ASPHALT EAlERGENCY ACCESS SAMON ,0RIPEIY.4Y SHALL HAKE A 29 S&PEREZFV.4TION TO THE EAST NOT TO SCALE EMST.. GROUND ;COTT/R. CIDLLINSZ Lic. No. 035791 L 6/17/21 ,�fj V/ Z z O a Q z z w � O O U m U U) W J Q z O Q I- W a U4 z w / W p p p N N cj rj w ti N N a\O L9 z 0! W W z 0 z Ul z J J U ti M CO N N O LU N J J_ C0 LU J Q 2 U i Y H D LU LU U) LU n" (Q V O O N J W 06 W H O 112066 SCALE AS NOTED SHEET NO. 6 CG-9D A ",� Vr �" "n.� d A• OR EXPANSION JOINT (4y� LIMITS OF PEDESTRIAN® AC ESS ROUTE iJPPAVen eev_e NON -TRAVERSABLE LIMITS OF PEDESTRIAN ACCESS ROUTE ,iNie0V geACr A c EXISTING OR PROPOSED h' V WIDTH pF SIDEWALK OR SIDEWALK SPACE C W r ENT-RANCEN CURB INCLUDED IN w ENTRANCE GUTTER EXPANSION JOINT v z } - C U _iG- LIMNS P DESTRI NON -TRAVERSABLE LIMITS OF PEDESTR AN CESS ROUTE ' SLOPE w4 CE55 ROUTE U W F a z EL PEDESTRIAN ACCESS ROUTE DETAILS WITH & &DN �� FLOW LINE WITHOUT UPAVED SPACE a� F ENTRANCE WIDTH ADDITIONAL RIGHT-OF-WAY IS REO RED IF THE LIMITS " 3 DESIRABLE MINIMUM 16' EXPANSION JOINT ABSOLUTE MINIMUM 12' OF PEDESTRIAN ACCESS ROUTE EXTEND BEYOND OR PROPOSED MOOT RIGHT -OF WAY. EXISTING 15" EDGE OF PAVEMENT , ® PEDESTRIAN ACCESS ROUTES PROVIDE A CONTINUOUS r UNOBSTRUCTED, STABLE, FIRM AND SLIP RESISTANT . s, • �. A PATH CONNECTING ALL ACCESSIBLE ELEMENTS OF A HALF PLAN FACILITY THAT CAN BE APPROACHED. ENTERED AND e. • e. • �• USED BY PEDESTRIANS. e • e .e �e•e•o.o 11F IF PEDESTRIAN ACCESS ROUTES M ARE BEING PROVIDED, SARIs REQUIREWITAMAX.2Y CROSS SLOPE. SECTIONoB-B WHEN USED IN CONJUNCTION WITH STANDARD OR CG-7, THE CURB FACE ON THIS 2'-0„ STANDARD IS TO BE ADJUSTED TO MATCH UNPAVED SIDEWALK $PACE THE MOUNTABLE CURB CONFIGURATION. ABOLIC SPACE •C, e. �. NORMAL GUTTERCETr1J­RV:E • p , p• •e. •e. •4. •P• •�• •D• I e•e•e •o• e.� q.o .c. •e. g.geq a o aA eo4ee'bd4ol'�q 4e.o 8ggqqq 160%TO 10%CHANGE •=e eo. o.eoee q� b" • SECTION C-C 6" AGGREGATE BASE CLASS A3 (H.E.S.I CONIC. TYPE ISIZE 218 2•.0• S 5'-0" ® POINT OF GRADE CHANGE 12% MAX.SLOPE FOR CURB AND CUTTER ONLY KI • e. • �, - p. z 12 % MAXIMUM INCREASE IN SLOPE AT MINIMUM 10' INTERVALS , p.• . p- FOR SIDEWAL.K.CURB AND GUTTE;x x x x 3 X MAXIMUM DECREASE IN SLOPE FOR FIRST D' INTERVAL AND 'e• BUILT CONCURRENTLY 8 % MAXIMUM DECREASE FOR SUCCEEDING MINIMUM 10' INTERVALS e•ee ee oo ee SECTION A -A a""' SECTION D-D STANDARD ENTRANCE GUTTER SPECIFICATION REFERENCE ROM AND BRIDGESTANDARDS SHEET 1 OF 1 REVISION DATE 502 203.03 07/15 VIRGINIA DEPARTMENT OF TRANSPORTATION GR-2, 2A X 27Y4" MIN - 28-Y4" MAX RAIL HEIGHT lRX; J J IJ GR-2 (6'-3" POST SPACING) MAX DYNAMIC DEFLECTION • 3' NOTES: GUARDRAIL LOCATIONS SHOWN ON PLANS ARE APPROXIMATE ONLY AND CAN BE ADJUSTED DURING CONSTRUCTION F AND AS DIRECTED BY THE ENGINEER. FOR DETAILS OF POST AND BLOCKOUTS SEE SHEET NO. 501.D5 FOR DETAILS OF RAIL ELEMENT, RAIL SPLICE JOINT, AND ASSOCIATED HARDWARE SEE SHEET NOS, 501,01 AND 501,02, RAIL ELEMENTS ARE FURNISHED SHOP CURVED FOR RADII BETWEEN 5 FEET AND 150 FEET. ALL GUARDRAIL POSTS SHALL BE SET PLUMB. POST SHALL NOT BE SET WITH A VARIATION OF MORE THAN/g" PER FOOT FROM VERTICAL. W-BEAM, BLOCKOUTS, AND POSTS SHALL BE SET AND ALIGNED WITHOUT ALTERATION OR FORCE, AS PER SECTION 505 OF THE SPECIFICATIONS. ALL GR-2 AND GR-2A RAL4" HALL BE MAINTAINED AT A HEIGHT OF 27{'4" MIN - 28 MAX AS MEASURED PER STANDARD GR-INS. ALL W-BEAM RAILS SHALL BE LAPPED IN THE DIRECTION OF VEHICULAR TRAVEL FOR THE FINISHED ROADWAY. THE OPTIONAL GR-2A METHODS OF NESTING THE RAIL OR USE OF AN ADDITIONAL RAIL CN THE BACK OF THE POST FOR STANDARD OR-2A SHALL BE APPROVED BY THE ENGINEER PRIOR TO INSTALLATION. 3' 1Vi' 3'-11/i' 3'-1V2" 3' 11Vi' 7�7A!R' !A/A)'J.V' �lA"l.J7aT iYY. III II J IJ IJ J IJ GR-2A (3'-4/=' POST SPACING) MAX DYNAMIC DEFLECTION 2' q T x OPTIONAL OR-2A METHOD x OPTIONAL GR-2A METHOD USING NESTED RAIL USING ADDITIONAL RAIL ON BACK OF POST x WHEN NESTED RAIL OR ADDITIONAL RAIL IS PLACED ON BACK OF POST FOR GR-2A THE POST SPACING WILL BE 5'-3". FLARE RATES DESIGN SPEED INSIDE SHY LINE BEYOND SHY LINE MPH SHY LINE LS FLARE RATE FLARE RATE 70 9' 30:1 15:1 * 60 B. 26-1 14:1 • 50 6.5' 21:1 11:1 • 40 5' 16:1 9:1 • 30 1 4' 13:1 1 7:1 • • SUGGESTED MAXIMUM FLARE RATE FOR SEMIRIGID BARRIER SYSTEMS. XVD❑T A COPY OF THE ORIGINAL SEALED AND SIGNED DRAWING IS ON FILE IN THE CENTRAL OFFICE. SPECIFICATION ROAD AND BRIDGE STANDARDS STANDARD BLOCKED -OUT W-BEAM GUARDRAIL REFERENCE SHEET 1 OF 2 REVISION DATE (STRONG POST SYSTEM) 221 505 501.04 08/14 VIRGINIA DEPARTMENT OF TRANSPORTATION .0 OF 4 7 2" R CURB 4 13" a 1 - I • 1f 6., 2' STANDARD CG-6 CURB && GU TTER NO SCALE f (VARIABLE WIDTH) 4" CONC. 3000 psi MIN. VDOT #57,#68, OR #78 STONE BASE UNDER CURB & CHECKED BY VDOT PRIOR TO PAVING AND/OR BACKFILLING. CG-12 NOTE: COMPONENTS OF CURB RAMPS CONSIST OF THE FOLLOWING: HYDRAULIC CEMENT SIDEWALK (DEPTH IN INCHES, AREA IN SQUARE YARDS) GENERAL NOTES CURB WHEN REQUIRED (CG-2 R CG-3 IN LINEAR FEET) WARNING SURFACE (AREA IN SQUARE YARDS) 1. THE DETECTABLE WARNING SHALL BE PROVIDED BY TRUNCATED DOMES. EACH OF THE ABOVE ITEMS IS A SEPARATE PAY ITEM AND SHOULD BE SUMMARIZED FOR EACH CURB CUT RAMP. 2. DETECTABLE WARNING SHALL BE FROM THE MATERIALS APPROVED LIST FOR DETECTABLE WARNING SUFA.CES. PRODUCTS NOT LISTED SHALL MEET SIDEWALK RAMP 12:1 MAX THE REQUIREMENTS OF THE SPECIAL PROVISION FOR CG-12 DETECTABLE 40:1 MAX WARNING SURFACE AND SHALL BE SUBMITTED TO THE STANDARDS AND SPECIAL DESIGN SECTION FOR APPROVAL. 3. SLOPING SIDES OF CURB RAMP MAY BE POURED MONOLITHICALLY WITH RAMP q• FLOOR OR BY USING PERMISSIBLE CONSTRUCTION JOINT WITH REQUIRED BARS. B 4. IF RAMP FLOOR IS PRECAST, HOLES MUST BE PROVIDED FOR DOWEL BARS SO MAX THAT ADJOINING FLARED SIDES CAN BE CAST IN PLACE AFTER PLACEMENT OF 10:1 PRECAST RAMP FLOOR. PRECAST CONCRETE SHALL BE CLASS A-4. TYPE A 5. REQUIRED BARS ARE TO BE NO. 5 X 8" PLACED T CENTER TO CENTER ALONG PERPENDICULAR BOTH SIDES OF THE RAMP FLOOR, MID -DEPTH OF RAMP FLOOR. MINIMUM CONCRETE COVER 1V2". 6. CURB / CURB AND GUTTER SLOPE TRANSITIONS ADJACENT TO CURB RAMPS ARE INCLUDED IN PAYMENT FOR CURB / CURB AND GUTTER. 5'MIN 7. CURB RAMPS ARE TO BE LOCATED AS SHOWN ON THE PLANS OR AS DIRECTED r 12 o T BY THE ENGINEER. THEY ARE TO BE PROVIDED AT INTERSECTIONS WHEREVER 12:1 MAX S AN ACCESSIBLE ROUTE WITHIN THE RIGHT OF WAY OF A HIGHWAY FACILITY CROSSES A CURB REGARDLESS OF WHETHER SIDEWALK IS EXISTING PROPOSED OR NONEXISTENT. THEY MUST BE LOCATED WITHIN PEDESTRIAN CROSSWALKS AS SHOWN ON PLANS OR AS DIRECTED BY THE ENGINEER, AND SHOULD NOT TYPE B BE LOCATED BEHIND VEHICLE STOP LINES, EXISTING LIGHT POLES, FIRE PARALLEL HYDRANTS, DROP INLETS, ETC. ACCESSIBLE ROUTES PROVIDE A CONTINUOUS UNOBSTRUCTED, STABLE, FIRM AND SLIP RESISTANT PATH CONNECTING ALL ACCESSIBLE ELEMENTS OF A FACILITY THAT CAN BE APPROACHED, ENTERED AND USED BY PEDESTRIANS. B. RAMPS MAY BE PLACED ON RADIAL OR TANGENTIAL SECTIONS PROVIDED THAT 12%1 MAX THE CURB OPENING IS PLACED WITHIN THE LIMITS OF THE CROSSWALK AND THAT THE SLOPE AT THE CONNECTION OF THE CURB OPENING IS 12`1- MAX PERPENDICULAR TO THE CURB. ** 5'MIN 9. TYPICAL CONCRETE SIDEWALK IS 4" THICK. WHEN THE ENTRANCE RADII CANNOT ACCOMMODATE THE TURNING REQUIREMENTS OF ANTICIPATED HEAVY TRUCK 4' MIN TRAFFIC, REFER TO STANDARD CC-13, COMMERCIAL ENTRANCE (HEAVY AT )K 2" HIGHER THAN TRUCK TRAFFIC) FOR CONCRETE DEPTH. , TR EDGE OF PAVEMENT 10. WHEN CURB RAMPS ARE USED IN CONJUNCTION WITH A SHARED USE PATH, \ \ AT XX . SAME AS TOP OF CURB THE MINIMUM WIDTH SHALL BE THE WIDTH OF THE SHARED USE PATH. 11 H v P PROVIDED F T WHEN ONLY ONE CURB RPM S ROV DED OR TWO CROSSINGS (DIAGONAL). TYPE C A 4' z 4' LANDING AREA SHALL BE PROVIDED TO MANEUVER A WHEELCHAIR PARALLEL & PERPENDICULAR INTO THE CROSSWALK WITHOUT GOING INTO THE TRAVELWAY. THIS 4' x 4' LANDING AREA MAY INCLUDE THE GUTTER PAN. 12. ALL CASES WHERE CURB RAMPS INTERSECT A RADIAL SECTION OF TRUNCATED DOME C-C m CURB AT ENTRANCES OR STREET CONNECTIONS THE DETECTABLE .6"" -�m d WARNING SURFACE SHALL HAVE A FACTORY RADIUS OR BE FIELD 0 0 0 z -MODIFIED AS RECOMMENDED BY THE MANUFACTURER TO MATCH (b THE BACK OF CURB. - O O O O O O - O O O O OO O TTLANDING RAMP c, 0 0 0 0 0 0 0 0 0 l a0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 iP 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 50Y-651. OF BASE DIAMETER 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOP DIAMETER DETECTABLE WARNING o AT BACK OF CURB _ 0.9"-1.4" I VARIABLE FULL WIDTH OF RAMP FLOOR SEE NOTE 12. F- BASE DIAMETER _ _ r PAY LIMITS DETECTABLE WARNING TRUNCATED DOME INSTALLED ON A RADIUS DETAIL DETECTABLE WARNING DETAIL 1v❑❑T SPECIFICATION CG-12 DETECTABLE WARNING SURFACE REFERENCE ROAD AND BRIDGE STANDARDS SHEET 1 OF 5 REVISION DATE (GENERAL NOTES) 105 203.05 01/15 VIRGINIA DEPARTMENT OF TRANSPORTATION 502 OR-2, 2A WASHER 9 Ia I - 5. �� n z L -- -_ f E J HOLE J1 : �i" HOLE a & NUT _ _'_ -- 6"x 8"x1'-2" TREATED 6 z6 x1 -2 HOLE w PIME BLOCK OR 0 RECYCLED MATERIAL. �q TREATED PINE 0 BLOCK OR a RECYCLED GALV. STEEL 10D o MATERIAL COMMON NAIL w SEE NOTE 5. w 6" WIDE BLOCKOUT FOR USE WHEN REPAIRING DAMAGED GUARDRAIL 6"z8"zt'-2" TREATED - CONTAINING STEEL BLOCKOUTS. PINE BLOCK z BLOCKOUT FOR MAINTENANCE '11 REPAIR ONLY STREATE OUTHERN PINE to - 19 T"II � 7Y4" LESS THAN 1'-0"' HOLE 6x8 WOOD POST 5 9�e 4"x 8"xi'-2" TREATED PINE BLOCK. STRONG POST THE CRT POST IS FOR USE WITH THE 4" WIDE BLOCKOUT W-O" POST GUARDRAIL REQUIRED STANDARD GR-10 TYPE IIIOR WHERE STFfpFR BY THE ENGINEER IN THE PLANS.IED Ty IF ..4 DETAIL A 4, Y4" DIA POST MAY BE HOT ROLLED OR WELDED. HOLE rLE$ GUARDRAIL INSTALLATION --_ SITES REQUIRING LONGER II GUARDRAIL POSTS n :Ij ry a 3. 11 f N 4„ 1 a NOTES P H II x TREATED 10" BOLT TREATED PINE w 1. ALL BOLTS, NUTS, WASHERS, AND OTHER o &%* &NUT BLOCK OR O STEEL ITEMS ARE TO BE GALVANIZED. -I III -III - III -III It RECYCLED w It MATERIAL w 2. ALTERNATE TYPE POSTS AND BLOCKOUT MAY 0 BE INTERCHANGED ON ANY ONE PROJECT WITH _ I' II W6x8.5 OR z THE RESTRICTION THAT THE SAME TYPE OF W6x9 POST AND BLOCKOUT MUST BE USED IN ANY It SINGLE RUN OF GUARDRAIL. - II 0 OPTIONAL HOLE t° 3. FOR DETAILS GUARDRAIL ELEMENT SPLICE 11 70 FACILITATE GALVANIZING JOINT, HARDWARE, ETC. SEE SHEET NOS. 501.01 AND 501.02. 31/2" DIA HOLES R 4. DRIVE NAIL BOTH SIDES WITHIN 2" OF THE TOP OR BOTTOM OF BLOCKOUT AFTER %" x 16 tr BOLT IS INSTALLED. HOLES POSTS g^ II RR II A AND BRACKETS TO BE Yi' DIA. CRT POST STEEL POST SPECIFICATION A COPY OF THE ORIGINAL SEALED AND SIGNED DRAWING IS ON FILE IN THE CENTRAL OFFICE. XVD❑T REFERENCE STANDARD BLOCKED -OUT W-BEAM GUARDRAIL ROAD AND BRIDGE STANDARDS 2316 (STRONG POST SYSTEM, POST AND BLOCKOUT DETAILS) REVISION DATE SHEET 2 OF 2 505 VIRGINIA DEPARTMENT OF TRANSPORTATION 08/14 501.05 4" 21-A STONE BASE CONCRETE SIDEWALK NO SCALE Tree Planting and Staking Detail Not To Scale DOUBLE STRAND #12 GAUGE WIRE WITH RUBBER HOSE & TURNBUCKLES 2'x2' HARDWOOD STAKE CUT & REMOVE BURLAP FROM TOP 1/3 OF BALL AS SHOWN SCARIFY SUBSOIL TO 4' MIN. DEPTH MULCH SAUCER FINISHED GRADE TREES UP TO 4" CAL. SHALL BE STAKED. TREES W CAL. OR LARGER SHALL BE GUYED WITH 3 EQUALLY SPACED TWISTED, #12 GAUGE WIRE WITH HOSE AND TURNBUCKLES. LOOP HOSE AROUND TRUNK ABOVE BRANCHES AS SHOWN, FLAG WIRES WITH COURVEY TAPE. REFER TO SPECS FOR ADDITIONAL INFORMATION. AMENDED SOIL MIX COMPACTED SUBGRADE EXISTING OR PROPOSED SIDEWALK OR SIDEWALK SPACE F EXPANSION JOINT CI<-] WIDTH OF ENTRANCE EXPANSION JDNT d O D„ U � W i rc W g � N J U w CURB INCLUDED IN iS U ENTRANCE CUTTER = W zA O w z io FLOW LINE W m ENTRANCE WIDTH EXPANSION JOINT DESIRABLE MINIMUM 16' a ABSOLUTE MINIMUM 12' 3 EDGE OF PAVEMENT C HALF PLAN WIDTH OF CC-98 ENTRANCE LIMITS OF PED. LIMBS OF PED. ACCESS ROUTE ® o ACCESS ROUTFIN UNPAVED SPACE NON TRAVERSABLE -' UNPAVED SPACE WIDTH OF ENTRANCE LIMITS OF PED, k"CTESSOF PED. CESS ROUTE ® NON -TRAVERSABLE = S ROUTE PEDESTRIAN ACCESS ROUTE DETAIL WITH & WITHOUT UNPAVED SPACE ADDITIONAL RIGHT-OF-WAY IS RE RED IF THE LIMITS OF PEDESTRIANACCESS ROUTE EXTEND BEYOND h--� EXISTING OR PROPOSED VDOT HT -OF WAY. RI 1 I ® PEDESTRIAN ACCESS ROUTES PROVIDE A CONTINUOUS °• • °' • °- UNOBSTRUCTEDSTABLE, FIRM AND SLIP RESISTANT PATH CONNECTING ALL ACCESSIBLE ELEMENTS OF A 4o:'o4a4o4o FACILITY THAT CAN BE APPROACHED, ENTERED AND USED BY PEDESTRIANS. P ACCESS ROUTE IS ADJACENT TO BACK OF CURB, MINIMUM WIDTH SHOULD BE 6'. SECTION F-F 1F IF PEDESTRIAN ACCESS ROUTES ARE BEING PROVIDED, A MINIMUM 4' TRAVERSfifd LE WIDTH IS REQUIRED WITH A MAX. 2X CROSS SLOPE. WHEN USED IN CONJUNCTION WITH STANDARD PARABOLIC CG-3 OR CG-7, THE CURB FACE ON THIS UNPAVED SIDEWALK CURVE STANDARD IS TO BE ADJUSTED TO MATCH THE o o •o • o • o MOUNTABLE CURB CONFIGURATION. o0 0. o • o • o 0 0•0. 0 NORMAL GUTTER-,® ® ------ ® SECTION E-E • o.� e. - c. • ti. . p• • �. • °• • 6• ' °p• 'be.q. gege x It OX TO 1OX CHANGE o •4'e 'o 44e.o eeq bebogQ?Sgeq' CLASS A3 (H.E.S.) CONIC. �gpeeA • 6" AGGR. BASE TYPE I SIZE 210 • �• 12% MAX. SLOPE I 5'•0" POINT OF GRADE CHANGE • �. ' b.• . p, FOR CURB AND GUTTER ONLY MIN • �. • �. • t;. FOR SIDEWALK CURB AND GUTTER x x 12 X MAXIMUM INCREASE IN SLOPE AT MINIMUM 10' INTERVALS . o •o • o • o BUILT CONCURRENTLY o.o•o•o• oo. o o • Kill C-C x x x 3 % MAXIMUM DECREASE IN SLOPE FOR FIRST 10' NTERVAL AND SECTION B % MAXIMUM DECREASE FOR SUCCEEDING MINIMUM 10' INTERVALS SECTION D-D SPECIFICATION REFERENCE STANDARD ENTRANCE GUTTER ROAD ,VDOT AND BRIDGE STANDARDS 502 REVISION DATE SHEET 1 OF 1 203.02 VIRGINIA DEPARTMENT OF TRANSPORTATION 07/15 1992 3.38 Source: Va. DSWC II1 - 401 Plate 3.38-2 iCOTT R. CtTLLINS_Z Lic. No. 035791 a L 6/17/21 ,�fj Z z O Q In F F- w � < ' 0P�0F u K DO U) U Q < w Z O0 Q F- w L (n z w LU W (D L 0 N N Q ­1 CD .--I L Uj TIM, LU LU U) O 00 N An U w O w Cxf 2 n. (n JOB NO. 112066 SCALE AS NOTED SHEET NO. 6A ACSA GENERAL WATER & SEWER CONDITIONS (June 27, 201.9) 1. WORK SHALL BE SUBJECT TO INSPECTION BY ALBEMARLE COUNTY SERVICE AUTHORITY (ACSA) INSPECTORS. THE CONTRACTOR WILL BE RESPONSIBLE FOR NOTIFYING THE PROPER ACSA OFFICIALS AT THE START OF THE WORK. 2. THE ALBEMARLE COUNTY SERVICE AUTHORITY SHALL HAVE ACCESS TO USE THE AIRSPACE ABOVE THE LOCATIONS OF CONSTRUCTION FOR THE FLIGHT OF UNMANNED AERIAL VEHICLES FOR THE PURPOSE OF IMAGERY COLLECTION. 3. THE LOCATION OF EXISTING UTILITIES ACROSS THE LINE OF THE PROPOSED WORK ARE NOT NECESSARILY SHOWN ON THE PLANS AND WHERE SHOWN ARE ONLY APPROXIMATELY CORRECT. THE CONTRACTOR SHALL, ON HIS OWN INITIATIVE, LOCATE ALL UNDERGROUND LINES AND STRUCTURES, AS NECESSARY. 4. ALL MATERIALS AND CONSTRUCTION SHALL COMPLY WITH THE CURRENT EDITION OF THE GENERAL WATER AND SEWER CONSTRUCTION SPECIFICATIONS, AS ADOPTED BY THE ACSA. 5. DATUM FOR ALL ELEVATIONS SHOWN IN NATIONAL GEODETIC SURVEY. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING MISS UTILITY (1-800-552-7001). 7. ALL WATER AND SEWER PIPES SHALL HAVE A MINIMUM OF THREE AND A HALF (3.5) FEET OF COVER MEASURED FROM THE TOP OF PIPE, OVER THE CENTERLINE OF PIPE. THIS INCLUDES ALL FIRE HYDRANT LINES, SERVICE LATERALS AND WATER LINES, ETC. 8. ALL WATER AND SEWER APPURTENANCES ARE TO BE LOCATED OUTSIDE OF ROADSIDE DITCHES. 9. VALVES ON DEADEND LINES SHALL BE RODDED TO PROVIDE ADEQUATE RESTRAINT FOR THE VALVE DURING A FUTURE EXTENSION OF THE LINE. io. TREES ARE NOT PERMITTED IN THE ACSA EASEMENT. ii. THE CONTRACTOR SHALL BE RESPONSIBLE TO COMPLY WITH THE NO- LEAD REGULATION REGARDING BRASS FITTINGS EFFECTIVE JANUARY 4, 2014 (SENATE BILL 3874 WHICH AMENDS THE SAFE DRINKING WATER ACT). 12. THE SEWER LATERAL BEYOND THE CONNECTION AT THE SEWER MAIN SHALL BE PRIVATE. THE SEWER LATERAL STUB -OUT SHALL UNDERGO THE ACSA LOW-PRESSURE AIR TEST TO SATISFY COUNTY TESTING REQUIREMENTS. VISUAL INSPECTION OF THE SEWER LATERAL STUB -OUT SHALL BE WITNESSED BY THE COUNTY BUILDING INSPECTIONS DEPARTMENT. THIS INSPECTION SHALL OCCUR UNDER AN "OTHER PLUMBING" PERMIT WHICH MUST BE OBTAINED BY THE CONTRACTOR. 13. THE SEWER LATERAL BEYOND THE CONNECTION AT A MANHOLE SHALL BE PRIVATE. VISUAL INSPECTION AND PRESSURE TESTING OF THE SEWER LATERAL SHALL BE WITNESSED BY THE COUNTY BUILDING INSPECTIONS DEPARTMENT. THIS INSPECTION SHALL OCCUR UNDER AN "OTHER PLUMBING" PERMIT WHICH MUST BE OBTAINED BY THE CONTRACTOR. 14. THE FIRE SPRINKLER MAIN DOWNSTREAM OF THE GATE VALVE IS PRIVATE. VISUAL INSPECTION AND TESTING OF THE FIRE SPRINKLER MAIN DOWNSTREAM OF THE GATE VALVE SHALL BE WITNESSED BY THE COUNTY BUILDING INSPECTIONS DEPARTMENT. THIS INSPECTION SHALL OCCUR UNDER AN "OTHER PLUMBING" PERMIT WHICH MUST BE OBTAINED BY THE CONTRACTOR. 15. ALL FLUSHING OF FIRE SPRINKLER MAINS SHALL NOT OCCUR UNTIL APPROVAL IS GIVEN BY THE ACSA. GOOD FOUNDATION MATERIAL ROCKY FOUNDATION MATERIAL B24"a. INITIAL BACKFlLL aza IN a' MIN MIN, MIN. MIN. 6" BEDDING #68 STONE * STABLE SOIL ROCK ;TONES THE BOTTOM OF THE TRENCH. REMOVE ALL STONES TO INSURE THE PIPE DOESN'T REST ON ROCK AND THEN COMPACT THE SOIL OR PROVIDE A 4" BEDDING OF #68 STONE. FOUNDATION IN POOR SOIL UNDER -CUT CONDITION II 4 INITIAL BACKFlLL 4 MI UNSTABLE a" B. 6' e' SOIL MIN, MIN. _ MIN MIN. #68 STONE \M YRANULAR FILL AS �APPROVED BY ACSA \ S L OL' CK� ASTABLE SOIL OR ROCK, NOTE 1. NO ROCKS SHALL BE ALLOWED WITHIN 24" OF THE WATER LINES. 2. NO ROCKS LARGER THAN 6" IN ANY DIMENSION SHALL BE ALLOWED ABOVE THE INITIAL BACKFlLL. 3.THE INITIAL BACKFlLL SHALL BE PLACED AND COMPACTED IN 6" LIFTS. 4. NO ORGANIC OR FROZEN MATERIAL OR DEBRIS SHALL BE ALLOWED IN THE TRENCH. 5. BELL HOLES SHALL BE DUG OUT IN ALL CASES. DUCTILE IRON WATER PIPE INSTALLATION & BEDDING NTS FIG. W-2 TD-2 JUNCTION BOXES, TRANSFORMER PADS, PEDESTALS, ETC. SHALL NOT BE LOCATED WITHIN THE RIGHT OF WAY, VARIES 'IC'EL, I s' III _. I _15' I r WATER SEWER 3 A o � LOCATION OF OTHER UTILITIES /(GAS, ELECTRIC, TELEPHONE, CABLE, ETC.) EASEMENT WIDTHS, WATER OR SEWER ONLY - 20' MINIMUM WATER L SEWER 30' MINIMUM x SEE PART 3, PARAGRAPH ➢I SEPARATION OF WATER L SEWER SYSTEMS. UTILITIES CROSSING A WATER OR SEWER EASEMENT SHOULD BE AT 90• TO THE RIGHT OF WAY. UTILITY LOCATIONS & EASEMENT WIDTHS NTS FIG. W-1 Tn_f PLACE 5' GALVANIZED " WITNESS " POST WITH CAPPED ENDS PAINTED BLUE IN REMOTE AREAS AS OIRECTED. MARKER LOCATION MAY BE SUBJECT v TO IT DEPARTMENT APPROVAL. FINISHED GRADE 0 II ADJUSTABLE VALVE BOX W/ LID II z u E N V LALAX _ M.J. GATE VALVE WATER b -_ _I 2500 P.S.. CONCRETE SEARING AREA. THRUST BLOCK d < NOTE IN REMOTE AREAS, VALVE BOXES SHALL EXTEND SIX (5) INCHES ABOVE GRADE. TYPICAL GATE VALVE NTS FIG- W-5 TD-9 151/2" E.I.I. W. 1574 CAST IRON CLFANOUr FRAME AND LID 10 1/4" INSTALLED FLUSH WITH FINISHED SURFACE CONCRETE COLLAR POURED 7 12„ SEE PAVEMENT AROUND CLEANOUT COVER EXISTING GRADE REPLACEMENT C3500 PSI) REQUIREMENTS •�-'•"- PVC FEMALE CLEAT ADAPTER au, Vf1T}1 INVERTED NUT SCREW CAP OR FLAT SLOTTED SCREW CAP No. S406-10 RASE ITH 10 1/4" BAND PIPE SEE BACKFlLL AND BEDDING° BEND REQUIREMENTS LKORRIN!-SEAL C PIPE SEWER LATERAL FUTURESANITARY LATERAL TYE 1` BOTTOM OF TRENCH SECTION 'A -A' ��• �' SEWER �✓ CUSTOMER'S PROPERTY EASEMENT OR RIGHT-OF-WAY y FUTURE SANITARY LATERAL (WHEN INUNE LAYOUT REQ'D)1 - --CAST I0.0N CLEANOUT FRAME AND LID h- E LLL LI X Y I II 1 I L f al i I WVE SEWER LATERAL A %CONCRETE 45° BEND' COLLAR 1 L JJ PLAN VIEW STANDARD SANITARY CLEANOUT IN PAVED AREAS 1/a BEND ES ' 1Rl� E •E r SECTION 2-2 PIPE DEGREE BEND DIMENSIONS VOL. TEE AND PLUGS VOL. SIZE OF (FEET) CU.YD. (FEET) CUND. BEND L H T L H T 90 2.50 2.50 3.01 0.24 4" & 6" 45 22 1/2 2.00 1.50 2.25 2.00 2.60 2.52 0.15 0.10 2.00 2.25 2.50 0.15 11 1/4 1.50 2,00 2.50 0.10 90 3.66 3.16 3.21 0.48 9' 45 2.66 2,66 2.77 0.26 22 1/2 1.66 2.16 2-69 0.13 3-16 2.91 2.66 0.32 11 1/4 1.66 2.16 2.67 0.13 90 4.83 3.53 3.42 O.B3 I & 12" 45 3.33 3.58 2.95 0.43 3.83 4.00 2.83 0.52 22 1/2 2.33 2.58 2.86 0.24 11 1/4 1 1.83 1 2.33 1 2.84 1 0.18 L THRUST BLOCKS ARE REQUIRED WHENEVER THE PIPELINE - CHANGES DIRECTION, CHANGES SIZE, DEAD ENDS AND AT VALVES. L USE 2500 P.S.I. CONCRETE. 3. NO CONCRETE SHALL BE POURED ON ANY PART OF THE JOINT. 4. THE CONSULTING ENGINEER SHALL BE RESPONSIBLE TO THE VERIFY THE TYPE & SIZE OF ALL THRUST BLOCKS.CONCRETE THRUST BLOCKS NTS FlG. W-3 TD-3 •' ^`S PRES9g1 n 3/4• MAZE PIPE COUPLING PPRaYEo EwAi I' TYPE x• , �� a / FM USE ON ATTACHED SN0.E FAIAILV RESIDExnAi NN ON DUAL RESIDcxnAL A11Y IMEWnIXON I `.ESERNQS. O NOTE NO SKAnD mnN6 1. 77 DUAL SERVICE f- COYPISMON r 31C DIAL£ PIPE COUPLING UNA"`R`MEB Eauu r TmE -E- SOFT f,4PPLR UP POP USE ON p AMLED SINGLE FAMILY RENDEDRU ANNCE WERE AN INNIGATICN MERx Is Nm PR.M., SINGLE SERVICE NOTE I) SACOLES 4ULL BE U4D ON M PPE TYPICAL SERVICE LATERAL INSTALLATION (5/8" & 1" METERS) NTS FIG. W-6A ID-10 12" / I e,17A� 3000 PSI CONC. BASE BENCH SLOPED TO FLOW CHANNEL 1/4" 1' MIN BRANCH :J FLEXIBLE CONNECTION -/ NOTE: WITH STAINLESS STEEL ALL CONNECTIONS TO BAND EXISTING MANHOLES SHALL BE CORED AND A FLEXIBLE ow CONNECTION " BOOT " INSTALLED TYPICAL MANHOLE PLAN SHOWING BRANCH TIE - IN TITS FIG. S-I-B TD-27 Top View 6" MINIMUM---W1 n�:t�.ycay.LaliFiv.r�mlcLG�•� 42' Minimum -LIUcotlon of 95% compaction requied d Galvanized SteelL Beam, W12 x 14 (min. size) 3' min. penetration into undisturbed soil , or as approved by the ACSA. a d 4' MI A a T^ 4" MINIMUM Side View d. .. 4 4 d.d \ a 45' TYPICAL THRUST BLOCK IN FILL AREA NTS FIG, W-38 TD-5 NOTE, MIN. 60' DI4HE MANHOLE 0 REQUIRED, NSEP TP.1 PRaP MANlOLE PVC WaSS 2• USE APPROVER FLE%IIILE RUBBER dMY n BAIT casKE'M STRP aDiPLTNc 0 27' RROP PIPE PIPE STRAPS (STAINLESS STEEL) O SPACER EVERY 6' VERTICALLY _ 90' RESTRAINED REND try_ SEWER INFLUENT • .. PYRE • p E• •�•'Y .•A" EI E. IE PLAN PROFILE MIN. 6- BEDDING WITH NO. 69 STONE L HEIGHT OF THE VERTICAL DROP PIPE WILL BE DETERMINED BY THE ACSA BUT SHALL NOT BE LESS THAN TWO (2)FEET. 2 VERTICAL DROP PIPE SWILL BE SDR 26 P.V.C, SIZED THE SAME AS THE INCOMING PIPE AND CONNECTEDID THE DROP FFEING WITH STANDARD GASKET JOINT. 3 VERTICAL DROPPIPESHALLBE STRAPPEDTOTHE MANHOLE AT PIPE JOINTS. STRAPS SMALL BE MADEOF STAINLESS STEEL 4. SHAPE INVERT AS NEEDED TO PROVIDE SMOOTH TRANSITION FROM DROP CONNECTION DISCHARGE POINT TO SPRING LINE OF MANHOLE INVERT. 5. DROP CONNECTION DISCHARGE FISTING SHALL BE ORIENTED AT 45 DEGREES, INTO THE FLOW- 6. VERTICAL DROP PIPE SHALL BE INSTALLED AT 90 DEGREES FROM THE ACCESS STEPS. 7. MINIMUM 72' DIAMETER MANHOLE REQUIRED FOR A 51NGLE 10" OR 12' DIAMETER DROP CONNECTION, OR TWOS" DIAMETER DROP CONNECTIONS. STANDARD INTERNAL DROP CONNECTION N.T,S. FlG, S-1-C2 TD-30 �E E n� PE a \E UP S s� `E �E o _ M vV (% `S rP z `s E oEy 0 Q g m�EW n(ud 0 N E ? ,E m � E E E , V "7L \ E u -E E „\F.0 a O 'EOvE <E c� E E LID„ NP ^ 2E H LU < O O TYPICAL MANHOLE FRAMIE &COVER N.T.S FIG SID TD-31 FINISHED GRADE 1TI�f�T -ITITI -TIT-ITI-TFT TIr-ITT-TR- A. TRENCH e *' REDUCER in r2500 P.S.I. CONCRETE THRUST BLOCK - - - - - - - - - - tl UNDISTURBED SOIL 19 MN - PROFILE VIEW} UNDISTURBED SOIL - EDGE - - _ OF TRENCH- • 24 MN ------- -----f '4 /REDUCER g' MIN. 4' .. f - -4 2500 P.S.I. CONCRETE THRUST BLOCK Y e" MN --- --- -�. n ---j- UNDISTURBED SOIL - EDGE v J OF TRENCH 24" MN. NOTES: PLAN VIEW • NOT TO SCALE • NO CONCRETE SHALL BE POURED ON ANY PART OF THE MECHANICAL JOINT. USE PLASTIC SHEETING AS PROTECTION FOR BOLTS. • 3' MINIMUM HORIZONTAL PENETRATION INTO UNDISTURBED SOIL ON BOTH SIDES OF TRENCH, OR AS APPROVED BY THE ACSA. • 3' MINIMUM VERTICAL PENETRATION INTO UNDISTURBED SOIL, OR AS APPROVED BY THE ACSA. • CERTIFICATION OF 95% COMPACTION REQUIRED IN TRENCH. • THE CONSULTING ENGINEER SHALL BE RESPONSIBLE TO VERIFY THE TYPE AND SIZE OF ALL THRUST BLOCKS. NTS FIG. W-3D 9 COVER LIFT NOTCH 12 3/8" WATER CAST IRON LID NOTES: (1) A 1-3/4" DIAMETER HOLE IS REQUIRED IN THE LID FOR TOUCH READ METERS. TYPICAL METER BOXES (5/8"-1" METERS) NTS FIG. W-7 TD-13 SEWER SERVICE LATERAL CONNECTION NOTES: 1. WHERE A SEWER SERVICE LATERAL CONNECTS TO A MANHOLE AND NO INVERT ELEVATION FOR THE SERVICE LATERAL IS INDICATED THE TOP CROWN ELEVATION OF THE SERVICE LATERAL PIPE SHALL BE AT LEAST 0.2' HIGHER THAN THE TOP (CROWN) ELEVATION OF THE THE LOWEST PIPE CONNECTED TO THE MANHOLE. 2. SEWER LATERALS TAPPED INTO AN EXISTING SEWER MAIN SHALL BE CONNECTED USING A PIPE SADDLE. 3. MINIMUM GRADE FOR SEWER SERVICE CONNECTION SHALL BE 2% (1/4" PER FOOT ) 4. ALL SEWER LATERALS SHALL HAVE A MINIMUM COVER 2' MIN DIAMETER OF 4". 5, ALL SEWER LATERALS SHALL HAVE A MINIMUM COVER OF 3 FEET. SALT TREATED FINISHED CROOND MARKER PLUG END OF MAIN LINE SECTION LATERAL IN LINE WYE-TEE PLAN VARIES R SEWER SERVICE LATERAL CONNECTION N.T.S. FIG. S-2 TD-33 NOTE HYDRANT MUST BE EQUIPPED NTH CHARLOTTES- MIILLE THREADS WHICH IS THE LOCAL STANDARD. LENGTH OF BRANCH VARIES 6' MIN Y TO 10' (2701 18^-22^ 7 CU. FT. vaLVE eox #68 STONE 42•MIN • :•� r 6" GATE .., VALVE 8" % 8' TEE 2500 P.S.I. CONCRETE ••! ` I .'�, BASE AND INS UST •"'' q } BLOCK AGAINST UNDISTURBED STABLE SOIL STEEL PILE RESTRAINED JONT FITTINGS WHEN THE SOIL IS DISTURBED OR WEN A HYDRANT IS LOCATED IN A FILL, IN ADDITION TO POURING CONCRETE, A STEEL PILE SHALL BE USED AS ADDITIONAL SUPPORT. NOTE 1. SURROUND WEEP HOLES NTH GRAVEL AND KEEP FREE OF CONCRETE. 2. MAINTAIN A 3 1/2' MIN. COVER FROM THE MAIN TO THE FIRE HYDRANT ( INCLUDING DITCHES ) 3. FINISHED GRADE SHALL SLOPE AWAY FROM THE FIRE HYDRANT AND VALVE BOX 4. THE GATE VALVE IS ALLOWED IN SHOULDER OR BEHIND THE DITCH. IT IS NOT ALLOWED IN THE DITCH. 5. FIRE HYDRANTS SHALL BE INSTALLED AT LOCATIONS WHERE WEEP HOLES ARE ABOVE THE PREVAILING GROUNDWATER ELEVATION. IF REQUIRED TO BE IN WET AREAS. THE WEEP HOLES SHALL BE PLUGGED AND THE HYDRANT SHALL BE PUMPED DRY. TYPICAL FIRE HYDRANT ASSEMBLY DETAIL N.T.S. FIG. w-4 TD-8 GRADE AIR RELEASE VALVE BRASS OR BRONZE PIPE E_ V BRONZE GATE BRICK SUPPORTS OR SOLID CEMENT BLOCKS TYPE 'K" SOFT COPPER STOP STONE NOTES: 1) A PRECAST MANHOLE CONE AND COVER WITH WATER CAST ON LID FOR TRAFFIC AREAS, OR A METER BOX ASSEMBLY IN NON -TRAFFIC AREAS, OR APPROVED EQUAL, SHALL BE USED. 2) FOR WATERLINES SMALLER THAN 12" USE A 1" A.R.V. AND FITTINGS. FOR WATER LINES 12" AND LARGER USE 2" A.R.V. AND FITTINGS. 3) IN SITUATIONS WHERE THE A.R.V. ASSEMBLY CANNOT BE OFFSET FROM THE MAIN AN ADEQUATE FOUNDATION SHALL BE INSTALLED SO THE WATER LINE DOES NOT SUPPORT THE MANHOLE CONE. AIR RELEASE VALVE (ARV) NTS FIG. W-9 TD-20 11 MIN EMBEDMENT SPRING LINE O OF PIPE NO. 68 STONE - - - REMAINING BACKFlLL SHALL NOT CONTAIN ROCK MATERIAL LARGER THAN 5' IN ANY DIMENSION -INITIAL BACKFlLL* (6" LIFTS) * THOROUGHLY COMPACTED BY HAND OR APPROVED MECHANICAL TAMPER -HAUNCHING -BEDDING 6" max 4" min -FOUNDATION (SHALL BE REQUIRED WHEN SOIL > CONDITIONS ARE UNSTABLE NOTE 1. OPEN CUTS IN PAVED AREAS WITHIN EXISTING VDOT RIGHT-OF-WAY SHALL BE BACKFILLED ENTIRELY WITH NO. 21A STONE. 2. FOR DUCTILE IRON PIPE THE BOTTOM OF THE TRENCH SHALL BE SCRAPED AND COMPACTED, AND ALL STONES REMOVED OR A 4' BEDDING OF NO. 68 STONE SHALL BE PROVIDED 3. WHERE ROCK IS ENCOUNTERED PIPE SHALL BE INSTALLED ON A MINIMUM 6" BEDDING OF NO. 68 STONE TYPICAL SEWER PIPE INSTALLATION IN TRENCH NTS FIG. S-3 TD-34 ;COTT/R. CNIPLINSt, Lic. No. 035791 a 6/17/21 Aj ,w ZZ (] J Q F z W 2: i c ' L i f OoU K� ^ U w CO U) U) IS ` C ❑ J L �FF♦ Z O x= F 113 Q L Ln z w W LT) Du p N N - M4 n co .\H ❑ w Zco r co co co 1 W N A0�"5� VA N W N � z Q Z J ® 5 0 Q J_ 0 O Z � IUj ,,,ma,,xx ~� 06 W " � w 1 Y � Uj LU O j 7 Z Ul ZLI O LU a V Ir-)^ LU J N~ f< V 0 0 0 N F U F w LLl p w cl� x OL In JOB NO. 112066 SCALE AS NOTED SHEET NO. 7 HIGH PT STA: 10+01.56 HIGH PT ELEV: 687.85OW PT STA: 11+59.82 PVI STA:10+24.06 LOW PT ELEV: 682.65 PVI ELEV:687.50 PVI STA:11+09.82 K:13.32 PVI ELEV:683.30 LVC:45.00 K:27.86 LVC: 100.00 co U-) Q0 0 Ln N 0 N 0 o00 �03 �� + cD cCJ� Ln } 6) N O � 00 T) 00 W _ Ln > U W um Uwri> cn> 685 680 6"X6" TEE (2) 6" G.V. 675 /--1.52% 4.90° 3.5' M N. 5' 1.0, H PT STA: 11+71.20 PVI S A:12+11.20 INTERSECTION OF PVI LEV:681.98 HATHAWAY STREET 21.67 L C:80.00 (STA 10+96.75) ANI DESOTO DRIVE (STA PROPOSED r- Co FIRE HYDRANT ASSEMBLYw/ + ° \ 6"x6" TEE & U v > (2) 6" G.V. > m PROPOSED 4" SANITARY SEWER LATERAL (TYP. ) PROPOSED 45° VERTICAL BEND .8' 1.6' 1' PROPOSED 8" SANITARY 670 SEWER CROSSING PRi OPOSED 12"x6" CROSS,_/j PROPOSED 45° (1) 12" G.V. & (2) 6" G.V. VERTICAL BEND C 665 PROPOSED 6" CL. 52 DI WATERLINE PROPOSED (1) 6" G.V. TYPE A BLOW -OFF ASSEMBLY loons 690 EXISTING GRADE (TYP.) 685 PROPOSED GRADE (TYP.) PROPOSED VDOT 6 8 0 STD. CD-i -5.00% FILL TO BE PLACED AT 95% COMPACTION (TYP.) 4" DUCTILE IRON SANITARY SEWER LATERALS q2� 670 665 660 M 00 M M tiIt O M00 OMrl O OO VVll N l 6 00 00 M 00 O ko ED w ko W ID lD w00 ko ko l0 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 DESOTO DRIVE PROFILE PROPOSEC TYPE A E P 700 EXISTING GRADE (TYP.) n\A/ PT cTA- 10i F7 nZ 700 LOW PT ELEV: 687.95 PVI S A:10+63.48 PVIELEV: 687+36 26.88 695 L c115.o° 695 o o PROPOSED GRADE (TYF co N Do 690 > �w A3% 690 -1. 3.5' MIN. PROPOSED 8" PROPOSED VDOT ROOF DRAIN STD. CD-2 685 CROSSING (i) 6" G.V. 3.4' PROPOSED (i) 6' LOW -OFF TYPE A BLOW-0 ASSEMBLY SSEMBLY 0 0 0 0 0 PROPOSED 6"x6" TEE, 675 (2) 6" G.V. PROPOSED 4" SANIT PROPOSED 6" CL. 52 DI WATERLINE SEWER LATERAL (TY 670 670 00 00 CO O 00 I� N 00 Ol W N CO Ol Ol 00 O (n G.V. & FF ARY P.) 9+50 10+00 10+50 11+00 11+50 12+00 12+50 �ANOKO COURT PROFILE 720 715 710 LOW P1I STA: 11+16.94 LOW PT ELEV: 682.13 PVI STA:10+66.94 PVI ELEV:682.92 K: 30.73 L C:100.00 705 m K) 0 C6u � � + Co +� O �w �w 700 u> co UW m W 695 PROPOSED GRADE (TYP PROPOSED 48 (i) 12" G.V. & TYPE A -- BLOW -OFF ASSEMBLY 680 PROPOSED 8" 1.8 ROOF DRAI CROSSING 675 4.9' PROPOSED FIRE HYDRANT ASSEMBLY w/ 12"x6" TEE. (1) 3.2" G.V. & (1) 6" G.V., 670 9 TO 8 PROPOSED 12"x6" CROSS, (1) 3.2" G.V. & (2) 6" G.V. CMH-3 TO MHz 665 I 1. 5' PROPOSED 12" CL. 52 DI WATERLI N N t OOl N O OCY) 00 ' , N N � 10 w 00 9+50 10+00 10+50 11+00 720 715 710 705 700 4 10+96.75) AND DESOTO DRIVE (STA 6 95 56.86) - EXISTING GRADE (TYP.) \ 690 685 -� s9q 680 __[ TIE-INTO EXISTING GRADE 4'� 675 670 REMOVE EXISTING 12" B.O.V. & TIE-IN TO EXISTING 12" DI WATERLINE 665 0 w W 0 N 0 M N Ol 4 N 00Ol w O ~ 00 O O) W n k L 11+50 12+00 12+50 13+00 13+50 �HATHAWAY STREET PROFILE VERTICAL GRAPHIC SCALE 5 n 25 5 10 IN FEET ) 1 inch = 5 ft. HORIZONTAL GRAPHIC SCALE ( IN FEET ) t inch = 50 ft. 20 NOTE: SANITARY LATERALS CROSSING OVER WATERLINE SHALL HAVE ADEQUATE STRUCTURE SUPPORT FOR THE SEWERS TO PREVENT EXCESSIVE DEFLECTION. IN ADDITION, THE LENGTH OF THE WATERLINE SHALL BE CENTERED AT THE POINT OF THE CROSSING SO THAT JOINTS SHALL BE EQUIDISTANT AND AS FAR AS POSSIBLE FROM THE SEWER. THE LENGTH OF THE SEWER PIPE SHALL ALSO BE CENTERED AT THE POINT OF THE CROSSING, SO THAT THE JOINTS SHALL BE EQUIDISTANT AND AS FAR AS POSSIBLE FROM THE WATERLINE. NOTE: ALL ROADWAY EMBANKMENT MATERIAL SHALL CONSIST OF SOIL AND BE PLACED IN SUCCESSIVE UNIFORM LAYERS NOT MORE THAN 8 INCHES IN THICKNESS BEFORE COMPACTION OVER THE ENTIRE ROADBED AREA IN ACCORDANCE WITH VDOT zoo? ROAD AND BRIDGE SPECIFICATION 303.04 NOTE: CLASS I BACKFILL MATERIAL SHALL BE CRUSHER RUN AGGREGATE SIZE NO. 25 OR 26, AGGREGATE BASE MATERIAL SIZE 21A OR 23.13, FLOWABLE FILL, OR CRUSHED GLASS CONFORMING TO THE SIZE REQUIREMENTS FOR CRUSHER RUN AGGREGATE SIZE 25 AND 26, PER VDOT ROAD AND BRIDGE SPECIFICATIONS, SECTION 302.03G. NOTES: i. ALL FILL TO BE PLACED AT 95%COMPACTION. 2. MINIMUM 3.5' OF COVER MUST BE MAINTAINED OVER W/L. 3. MINIMUM OF i' OF VERTICAL SEPARATION FROM STORM SEWER & W/L AND i.5' OF SEPARATION BETWEEN W/L & SANITARY SEWER MUST BE PROVIDED. Lic. No. 035791,E 6/17/214i Z 0 a k z w ou - F O V En m En Ln ` i V/ J a w H Z 0 < 1� o i Z w uj j ° to w i ` Ii ; p N N •--� •--� QLu Mo M .\-I N N to Lu z O ti M ® M N 0! M W N CD O N N W � z w Q J zLu J 0 V) < Lu ul O z J O I � . z� _[_ . w W" CIO-00�. z LA U z Q ®Lu Q zw U H Lu Q O O N Lu O w I ce o_ Ln JOB NO. 112066 SCALE 1- 501 SHEET NO. 8 HIGH PT STA: 10+16.98 HIGH PT ELEV: 672.81 �TH 0 PVI STA:10+34.40 PVI ELEV:672.99 K: 2.59 LVC: 40.00 SCOTT R. LINS'Z o m o o t-) Lic. No. 035791,E 4 � 4 o ��0 6/17/21 �4 o o SSIONAL W W w 675 co > 675 z w z 0 U 0 C i i U0 N N FU Z \ vLo W OU 690 690 t- o z > w w Z o a z � 0~ o a o o w o U V U o f m a z w w Ln Ln Q O j j 3 0 U O O o u 0 w w U U O F a Lu L O U) z w ¢ < < a a to w f � 0 LLJLu Hamm a a nW 0 0- 0- w 0 0 w w w 007 0 U 2 0 U O OO •--•--'o W N N N w O\l '� N N to 0 0 U � c z r 0 ti 0 M w (y 3 N 0 a T 0! 'IT 0 WN o O O N N ° W Q z ° Q a ILL! J 0+00 10+50 11+00 11+50 12+00 12+50 J a PRIVATE ROAD PROFILE w Q J ~ m 10 L9 o p zJ Q � a 2 ~� O C) n W �/ Q LL Y 0 0 W Q U a z ul Z w z W w z W Q z w '^ N Z (- V i J U � U �- NOTE: ALL ROADWAY EMBANKMENT MATERIAL W SHALL CONSIST OF SOIL AND BE PLACED IN o SUCCESSIVE UNIFORM LAYERS NOT MORE THAN 8 Q INCHES IN THICKNESS BEFORE COMPACTION OVER Ur m THE ENTIRE ROADBED AREA IN ACCORDANCE WITH x VERTICAL GRAPHIC SCALE VDOT zoo? ROAD AND BRIDGE SPECIFICATION 303.04 C) N e ° 2.s a is 20 0 NOTE: CLASS I BACKFILL MATERIAL SHALL BE CRUSHER RUN AGGREGATE SIZE NO. 25 OR 26, AGGREGATE BASE MATERIAL SIZE 21A OR ziB, FLOWABLE FILL, OR CRUSHED GLASS ( IN FEET) CONFORMING TO THE SIZE REQUIREMENTS FOR CRUSHERu E inch = 5 ft. RUN AGGREGATE SIZE 25 AND 26, PER VDOT ROAD AND �j BRIDGE SPECIFICATIONS, SECTION 302.03G. o L HORIZONTAL GRAPHIC SCALE a Ln 0 U 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 17+99.50 so 0 2e so 100 200 NOTES: JOB NO. i. 0. ALL FILL TO BE PLACED AT 95%COMPACTION. 112066 PRIVATE DRIVE PROFILE MMEI z. MINIMUM 3.5' OF COVER MUST BE MAINTAINED OVER W/L. SCALE IN FEET) 3. MINIMUM OF i' OF VERTICAL SEPARATION FROM STORM 1 inch = 50 Ft. SEWER & W/L AND i.5' OF SEPARATION BETWEEN W/L & 1 - S n SANITARY SEWER MUST BE PROVIDED. SHEET NO. N 9 ° -2.00% 07 LOW PT TA: 12+55. 0 LOW PT ELEV: 643.8 PVI STA: 12+09.88 p PVI E EV:647.63 670 K:1s.00 670 cO N � N N 665 ±w w 665 >m W � m 660 660 FILL TO BE PLACED AT 95%COMPACTION (TYP.) 6rjrj HIGH T STA: 12 59.34 6jj PROPOSED VDOT STD. CD-i PVI STA: 12+7 .34 I ELEV:641.81 K: 5.24 LVC: 40.00 650 PROPOSED GRADE (TYP.) � 650 � � N U 645 U m � W 645 W EXISTING GRADE (TYP.) -8.37% 640 640 PROPOSED VDOT STD. CD-i 635 635 630 630 FILL TO BE PLACED AT 95%COMPACTION (TYP.) 625 625 LOW T STA: 16+ 9.98 LOW T ELEV: 59 .55 o PVI STA:15+72. 5 P I ELEV:594.9 620 K:9.63 620 \ rn � � rn� u� Sri o � r� ri o� 615 � �� 615 PROPOSED VDOT�� � � STD. CD-i m � w \ W 610 610 00 HIGH T ELEV: 593 PVI TA:17+17.7 PVI ELEV:592.00 K: 19.88 605 PROPOSED VDOT VC:100.00 605 STD. CD-i u� o� u� o 600 �� �00 Um UCJ m W 595 595 2.00% PROPOSED VDOT STD. CD-i 59 0 59 0 FILL 95%COMPACTION TO BE PLACED AT (TYP.) PROPOSED VDOT STD. CD-i 585 -7.03% 585 01 1� O ~ M V1 00 rl N °° n �t a0 N t!1 ri L!1 Vl t!1 V1 l!1 l0 00 O rl � N M � O t0 W 1p r! O t0 O W !'1 l0 � N � N .t � 1p M � W N 0 O N t0 O � Ol Ol � 111 Ol � .t Ol h'1 ci Ol N W CO � l0 CO ^ � � M M O � � Ol � � HIGH T STA: 10+ 2.02 HIGH PT ELEV: 6 5.36 685 PVI STA:10+72. 6 685 P I ELEV:676.78 K: 17.30 LVC:140.00 ro � 680 � + 680 Li > m Gi > Li 675 675 � a 4 �03 FILL TO BE PLACED AT POSED GRADE (TYP.) 670 95%COMPACTION(TYP.) � 670 665 EXISTINGGRADE(TYP.) 665 660 660 655 655 650 650 O � .{ N O N N� � l0 �p �p 1p^ v,n„v-,Z mCm0 T=0zm nmMOn DAnN r M Mtn D Occ0Ul zT :U - tn D m N co n C) O a)D mAG-D� r')m n-0m �C)DG)F= ODLAr W mnLml3 o rn0>> o N T m m w m 0 CO E2 Gam, ADD D -un mun r O G1Dy N � � r m0AW m = D m Acorn GtnLnc O m m = mm�N' A D > C: 0 C: 0 A A z Zrn N 3 po GDl co Zm M Mun0L) mOD� m M co m r m OWN W N 1' Z 0 D m33Dm Z * Z Z " DAccr <ROK, un*OW O m r M VL co E>"-0m mZ0mv AOmr"lr GOn V -�mm -j0�;0 WmDKD M Ln C � -0 LA A D m 00 0-j�K0 p 0 > D mZ>n D 1 m Z Q m 0 m Z m K O O z �unm �0;0 RO r PROJECT Ln I -A 0 0 0 0 0 0 0 0 CD 0 Z 0 0 F0 q 0 X N + o 0 N 0 N 0 0 CA 0 0 CA 0 0 0 0 0 0 o Z 0 cn 0 0 V 0 T] F- 0 0 0 0 0 0 0 0 0 0 0 0 0-) 0-) J J 00 00 CD CD O O O cn O CP O U O U O U 679.9 STR: AVONPK-1-13 TP=679.39 680.34 \INV IN: 670.98 TO MH-2 INV OUT: 689.8 N N v 0 D 681.io TA nN m N � �n a 59o.4 681.85 STIR: MH- TP=681.9 INV IN: 67 . 9 TO MH-3 692.6 INV IN: 673.79 TO MH-6A Ln INV 0 67 59 TO AVONPK-1-13 681.97 \ N 694'9 W 00 D 0 v u, o 0 x Ln 684.81 0 r A m m O z G1 to I o n ON D 694.9 o LnG) z O n D mm m 686.74 o � / v STIR: MH-3 693.2 0 TP=688.78 NV IN: 679.37 TO MH-5 688.g6 N a INV IN: 679.39 TO MH-4 'n z INV OUT: 679.19 TO Ml (F7 a+ n STIR: MH-4 a TP=690.05 INV OUT: 680.57 TO MH-3 0-) 0-) 0-) 0-) 0-) 0-) 0-) 0-) J J M M J J 00 00 c0 c0 O O O U1 O U1 O U O U O U1 0-) 0-) 0-) 0-) 0-) 0-) 0-) 0-) J J 0-) 0-) J J 00 �D C0 O O O CJ O U > D UO UO U M A 00 -MOB O mA. m O n O LI)m 0 O� n ZDO m X rn m z Gl m LA 693.2 L o STIR: MH-3 m TP= 3 .78 Z � 688'77 _ INV IN: 679.37 TO MH-5 0 INV IN: 679.39 TO MH-4 m N INV OUT: 679.19 TO MH-:-I `z CO cn < 59i.9 J U) T A - 687.92 nN a o N L �n 0 STIR: MH-5 TP=687.98 INV OUT: 681.53 0 MH-3 0-) 0-) J J 00 00 CD CD O O O (J1 O O (11 O Ul O Ul M 0-) 0-) J J J J 0 03 DO (0 (0 O O O U O U O U1 O U1 O U1 o Ln M O Gl D 0 m 69o-7 STIR: MH-2 TP=681,92 68i.93 INV IN: 674.59 TO H-3 INV IN: 673.79 TO MH-6A INV OUT: 673.59 TO AVONPK-1-13 u, 0 �n = m Ln STIR: MH-6A TP=681.16 68i 8 4 ,r, z N 77 7 Pn O j oo INV IN: 674.27 TO MH-6 o < 00 INV OUT: 674.07 TO H-2 0 / 3'n my 678.7 o o -p 679.07 n STR: MH-6 x TP=678.19 INV OUT: 674.58 IU MFW6A z c) G1 D O 0-) 0-) 0-) 07 07 C-) 0- 0) J J J J 00 00 O O O O O CJ O O CJ O U O U DATE 9/16/20 11/13/20 12/03/20 2/11/21 M 0 I� � N0 AVON PARK II - ROAD PLAN 6/17/21 0 m ° P SHEET SANITARY SEWER PROFILES COLLINS ENGINEERING 200 GARRETT STREET, SUITE K.-CHARLOTTESVILLE, VA 22902-434.293.3719 REVISIONS REVISION DESCRIPTION INITIAL SUBMITTAL REVISED PER ACSA COMMENTS REVISED PER ALBEMARLE COUNTY AND VDOT COMMENTS REVISED PER ALBEMARLE COUNTY COMMENTS DATED 1/8/21 REVISED PER ALBEMARLE COUNTY COMMENTS DATED 1/8/21 r 0 J O J O J O _J O J O These plans and associated documents are the exclusive property of COLLINS ENGINEERING and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but not limited to construction, bidding, construction staking without the express written consent of COLLINS ENGINEERING. 710 710 710 710 EXISTING GRADE (TYP.) ^ 705 `° 705 _ J PROPOSED GRADE (TYP.) v ^ M o STR:5 VDOT STD. DI-3B (L=6') � I TP=677.93 m N 700 INV IN: 669.57 TO 6 STR:8 VDOT STD. DI-36 (L=6') II M cn o INV OUT: 669.47 TO 5A TP=683.53 I `'rn CO INV ": 672.18 TO 9 IP p 676.08 TO C4 a M 0 = 0 o�oo o 00 > INV 00 o oil 695 INV OIv 672.08 TO 7 m 0 __C) V) 0om7 F N -0) -`moo m II 695 o m I M o-oo^ o(o�ao° f`(o -Naz J v 0 O 00I_ O r� 0) (ON ~ nNtl_ > (0.. Lj F OloZ Z= .-. m Hd. O inn r"(O (O- -0 690 0 `o M�� ��ZZo NaZZZ 690 0 0 00,, �(o �= = co �� > �� N aZ ZZ M �O H f`O* (0? -0/ 0 o O~ O Mr(o d a>» yi 685 � >r�� N�zZZ FRS ~o-rnrn� (0(0zo. PROPOSEDE r_:10 6� p» WATERLINE >allo� U) I-zz -- CROSSING <r . ..� (n(Dz z0 / 1.0' 680 >> 680 PROPOSED 12" WATERLINE CROSSING 1' MH-3 TC o 675 0 0 0 o 4.9 15" RCP )75 PROPOSED 6" 2.1' 62.29 LF ®2.47% FILL (TYP.) WILCROSSING 15" RCP r12' --«- 75.52 LF ® 1.69% TIE -INTO SWM FACILITY 15" RCP - 15 RCP 670 INV=667.50 60.44 LF ® 0.91% 10 LF Gp PROPOSE SANITARY gg SEWER LATERAL TYO% LF ®Z 15" RCP 665 �� �g 63.95 LF 0 1.00% 665 15" RCP 15" RCP 6.59 LF 0 4.85% 27.97 LF ® 4.00% 660 660 655 655 n a o "0v, v,kDo a 0 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 �STR-11 TO SWM 1 PROFILE STIR: 10 VDC I I IN 705 705 EXISTING GRADE (TYP.) N 700 1 700 U M 0 o mo 695 �� 695 Lo m . r rn� DD M�0 0 � > Cq PROPOSED N 00. 690 GRADE - co-C) 690 � I11 L V)Hzz T STD. DI-3B (L=6') TP=685.76 NV IN: 679.28 TO 11 NV IN: 681.18 TO 12 685 V OUT: 679.18 TO 9A 680 680 3.3' 15" RCP LJ 43.78 LF 675 PROPOSED4"SANITARY 675 SEWER LATERAL (TYP.) 670 670 N Cn OLn 00 Ln 0 m -0+50 0+00 0+50 1.42% �STR-12 TO STR-10 PROFILE PROPOSED Gf EXISTING G ^ 685 3 J 685 2 !n g m tOo M Q I no d 00~ �-N 0 wo O~ o r2'D �� 000O > 00 (0 O 00 0 OO(O(0 cow.. Q� H " D �n�z zo > (V (o r • •=) I>» (0-0 11 675 a>> In I-- 670 670 'ADE (TYP.) 665 665 15" RCP 64. 33 LF ®0.9 RADE (TYP. 660 660 FILL TO BE PLACED AT 95% COMPACTION (TYP.) 655 655 650 650 S 0010 It O D (0 O 0+00 0+50 �STR-16 TO STR-5A PROFILE WA mtel 710 705 705 STR:13 VDOT STD. DI-3B (L=8') TP=680.80 700 INV IN: 673.47 TO 14 00 - INV IN: 677.12 TO A2 J INV OUT: 673.37 TO 9 EXISTING 10 (¢ O Moo GRADE (TYP.) 11 1 695 m 95 oo - H^ M M O ^m I O cpN -r- N� 0 O 0 o mr- � d 0 M (O (0 .. ro M 690 0) 00oz ZD V) 90 (o- -O o a> >> > (D C (moo PROPOSED a> 685 GRADE (TYP.) N ~z 385 680 380 PROPOSED 3.2" WATERLINE CROSSING PROPOSED 6" TERLINE CROSSING _/" MH-3 TO MH-2 675 4.8' 1.2' 1' 75 670 370 15" RCP 35.98 LF ®0.5 15" RCP 665 140.37 LF 0 0.50% 6 5 1� N N ,y DO W N M ul N M 6 w 0) 00 ID � � 0+00 0+50 1+00 1+50 2+00 �STR-14 TO STR-9 PROFILE 0% EXISTING C PROPOSED GF STR:7 VDOT STD. DI-313 (L=6') TP=680.88 700 1 INV IN: 673.34 TO 15 INV IN: 671.44 TO 8 INV OUT: 671.34 TO 6 700 J 695 m 695 I r O V) Co 690 0 690 �(D > CO .. o (Lo Y II> 685 V) ~Z 685 RADE (TYP.) 680 680 AIDE (TYP.) PROPOSED 6" ri6' CROSS 675 TWATERLINE 675 670 L 15" RCP 70 28.07 LF ® 1.71 665 665 n s� 0 o co � ID 0+00 0+50 ING FSTR-15 TO STR-7 PROFILE VERTICAL GRAPHIC SCALE ( IN FEET ) 1 inch = 5 ft. HORIZONTAL GRAPHIC SCALE 0 25 50 100 ( IN FEET ) 1 inch = .50 ft. NOTE: ALL DRAINAGE STRUCTURES WITH A DEPTH OF i2' OR GREATER SHALL HAVE SAFETY SLABS IN ACCORDANCE WITH STANDARD SL-i AS FOUND IN THE 2oo8 ROAD AND BRIDGE STANDARDS. NOTE: HDPE CAN BE USED AS AN ACCEPTABLE SUBSTITUTE FOR RCP FOR THE DRAINAGE PIPES. SEE DETAIL ON SHEET 17 FOR HDPE PIPE BEDDING INFORMATION. NOTE: ALL DRAINAGE STRUCTURES WITH A DEPTH OF 4' OR GREATER SHALL HAVE STEPS IN ACCORDANCE WITH STANDARD ST-i. AS FOUND IN THE 2oo8 ROAD AND BRIDGE STANDARDS. NOTES: 1. ALL FILL TO BE PLACED AT 95%COMPACTION. 2. MINIMUM 3.5' OF COVER MUST BE MAINTAINED OVER W/L. 3. MINIMUM OF i' OF VERTICAL SEPARATION FROM STORM SEWER & W/L AND 3.5' OF SEPARATION BETWEEN W/L & SANITARY SEWER MUST BE PROVIDED. NOTE: CLASS I BACKFILL MATERIAL SHALL BE CRUSHER RUN AGGREGATE SIZE NO. 2S OR 26, AGGREGATE BASE MATERIAL SIZE 23.A OR 21B, FLOWABLE FILL, OR CRUSHED GLASS CONFORMING TO THE SIZE REQUIREMENTS FOR CRUSHER RUN AGGREGATE SIZE 25 AND 26, PER VDOT ROAD AND BRIDGE SPECIFICATIONS, SECTION 302.03G. 200 Lic. No. 035791,E 6/17/21 40i Z O ¢ k z w E ou - F O U m E e En Q z 0 <w F- D `H v) z w / W > Lu V) w` c Of; p N NLu •--� •--� CD to �A in 0 C) O N P-M Lu w a Ln JOB NO. 112066 SCALE ill _50 SHEET NO. 11 � �M TH OFF 680 00~ 680 w� o �� �� II SCOTT R. LINSZ 00Ci �o v O� Lic. No. 035791 FILL TO BE PLACED AT > N m� QI o d6/17/21c4 675 9S% COMPACTION (TYP.) It Z p 675 J °� 1 z , a>> 685 M 685 685 o O 685 W t- �o Z Z_Z4�SIONAL E� u O~ z F w 67 �t 670 oo� 00 o 0 m (00 o �— 0 M (oZp a>> NFzz SEE VSMP N o 66 PLAN FOR p H r, r, PROPOSED GRADE (TYP.) Z SWM i w '+ a DETAILS O V y F m LO o z o z z 66J 660 w > w w m 15" RCP Z o a� z� 2 r r>o 11.84 LF ® 4.56% a k o a o o 3 _ O~ 0 w a o �M P Z w m F-M w Ln Q O V 65 0 6v) 655 @ 7.91%, Z< w J o 0 o O r) > pcoF tij°I° SAFETY SLAB ` J J 1a�Zo �GQ 0� (SL-i)REQ'D / > Z o w 0 co-O a ® W w m m mu Vi a>> 1h °c � a a N F-Z 6� w w 65 6�. 650 w a a LO o 0 > Ln L w w w 0 645 645 SAFETY SLAB 0 Qm Gee (SL-i) REQ'D y 0 640 x � O)n1�� 640 U 0 I- r)°o 1 . Lu O O NO 6 Q Mo •--� E > SOH O ti ti N �o 63J m`(0-0 635 n>> 0 azz D SAFETY SLAB —0+50 0+00 0+50 —0+50 0+00 (SL-m) REO'D 63 EXISTINGGRADE(TYP.mM ecj.N�,��� 630 �STR-17 TO SWM-1 PROFILE FST-R-18 TO SWM-1 PROFILE z N roo a Q ® M o 3 x 0tf') ^hV ® � m cyi N 04 o 62 0 No ��� 625 oo� M >rnio.. Off. j O M�ZO N o V) a» O 62 `�~ZZ 620 N CV SAFETY SLAB ; z o (SL-1) REQ'D Q 61 UN GQ �"'� 615 J LU W = 0 o0 �® J J o 1nN � 0 LL 61 cc 00�� ro� 610 VERTICAL GRAPHIC SCALE � >rnn.. L9 � o 5 0 25 5 10 20 3 Op..o C r)OZ0 a» ^/ W -o L1 ZZ \ D p- � � ( IN FEET) �� 5 D 60 �� 605 1 inch - 5 ft. _ �--1 o LLJ No ON SAFETY SLAB a x o o o (SL-i)REQ'D HORIZONTAL GRAPHIC SCALE U 5 0 ~� O 0 Lr) 50 0 25 50 100 200 L x �� o�1n.. Q . 60 � (6 NMZ~ ��� a �_p 600 Via» Oroo ( IN FEET ) � 0 > V7I--ZZ C�. 1 inch = .50 ft. ul V) z �in-O -- a» w w LO I-zz Z 59 c J g cJ NOTE: ALL DRAINAGE STRUCTURES WITH A DEPTH W a z OF iz' OR GREATER SHALL HAVE SAFETY SLABS IN N PROPOSED VDOT STD. ES-i ACCORDANCE WITH STANDARD SL-i AS FOUND IN ? WITH RIPRAP OUTFALL THE 2oo8 ROAD AND BRIDGE STANDARDS. U) o U GQ NOTE: HDPE CAN BE USED AS AN ACCEPTABLE `o 59 ��� 590 SUBSTITUTE FOR RCP FOR THE DRAINAGE PIPES. Lu `� F SEE DETAIL ON SHEET 17 FOR HDPE PIPE a BEDDING INFORMATION. ° n INV. OUT=585.9 1 �1 J > -- NOTE: ALL DRAINAGE STRUCTURES WITH A DEPTH 58 15 RCP OF 4' OR GREATER SHALL HAVE STEPS IN x 51% 585 ACCORDANCE WITH STANDARD ST-i.AS FOUND IN O ° 91.28 LF ®1 THE 2oo8 ROAD AND BRIDGE STANDARDS. N Y 15" RCP 23.79 LF ® 1.00% PROPOSEDIVDOT STD. CLASS II NOTES: Jg RIPRAP CHANNEL OUTFALL 58O i. ALL FILL TO BE PLACED AT 95%COMPACTION. E w/ GEOTEXTILE FILTER FABRIC UNDERLAYMENT 2. MINIMUM 3.5' OF COVER MUST BE MAINTAINED OVER W/L. (4:i SIDE SLOPES, D=3' MIN.) 3. MINIMUM OF i' OF VERTICAL SEPARATION FROM STORM G � m m i. m SANITARY SEWER MUST BE PROVIDED. ce o SEWER & W/L AND � W .t l0 Ol l!1 O m P'1 n S d' 2 i.S O w W Ol d ,y l6 ri ci N f�'1 S M M O O O 'U m m Ol Ql O •i N M .t L!1 lD v1 o v1 cn v1 � w �o w w '0 W W 'o JOB NO. 112066 o NOTE: CLASS I BACKFILL MATERIAL SHALL BE CRUSHER RUN AGGREGATE -o SIZE NO. 25 OR 26, AGGREGATE BASE MATERIAL SIZE 23.A OR 21B, FLOWABLE SCALE 0 —0+75 —0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 FILL, OR CRUSHED GLASS CONFORMING TO THE SIZE REQUIREMENTS FOR 111 = 501 `o CRUSHER RUN AGGREGATE SIZE 25 AND 26, PER VDOT ROAD AND BRIDGE a SWM 1 T 0 0 0 T F A L L PROFILE SPECIFICATIONS, SECTION 302.03G. sHeer No. N 12 r H 0-0)- 1 �N � �O O~ 680 � "°° 680 O oad� 0 0 oo� > ozo PROPOSED GRADE (TYP. � 675 azz -- 675 FILL TO BE PLACED AT 95%COMPACTION (TYP.) 670 67� TIE-INTO SWM FACILITY INV=667.50 665 6c5 15" RCP EXISTING GRADE (TYP. 13.42 LF ®5.59% 660 660 655 655 650 650 ROPOSED H O O p 00 680 to0 680 � � az GRADE (TYP.) 675 675 FILL TO BE PLACED AT 95%COMPACTION (TYP.) 670 � 670 TIE-IN SWM FACILITY 15�� RC INV=667.50 5.06 LF 665 665 EXISTING GRADE (TYP. 660 660 655 655 650 650 N 68°T N 68� mJ 684 - - - - - - - - - - - - - - - -- _ - - - _ - - - STR. a NO. B2 131 )o�- x �- - - nO. m0 10 x _ \ 8 -- X\ I � \ V 7 B4 X v v :- ` / A 6 - 00 ANO COURT r-� 5 PRjVI I 12 11 I N_ C1 �� --- - --- / / A ` \ _i/ SWM1 10 - -� Al 4A oFXO "u'O / / V - - --- 4 7 - - - 69o> +� -- -� e I •4� 1 �o 00 wo OUT 12 14 H I � r r0 13 E3 _ --- --- 9 \ \ ` r r r _ ` \ \ 61 70 PRTVATR ROAD / '\ - - - - - - - - - - ` _ \ 66$ 4 PRNAT& ACC8S3-BASYE'N�'- -- - __ - 16 -306 ` v - - - - - - - - - - - 5A \ ` ` I-- / - - 6518 --- \ 6 - v �v A----654 -552- \ t / S j 25 g 9 ' 65z - --___ ----- - -- - / V ` 24 �648 - ---- ---- -- So 648 _ \ ` `----------- x - _ 648�_ - - - - ---- - \ 646 1y6 - 646- _ -- --- -` - - - -- / \ 44 � --640 1 -636- 638 \ I-&3?`C634i"W- - - 636 4 -632 3 3 \ -634- - 632 36 1 626 - - ` - - - - \ 111m -- ---- 34 630 32 r - � r r I _ - 2 z \ _ @ I I Norm" 1 ,\ _ -62tQ O �,Q��_ - -- -6z4 T111 6' 624 TP 3C �v sus �i v �,� 23- 2 N- 23 60,9- -6z6 \\-n OF CONCENTRATI PATH 00 h \ 06' -6 0' OF 'OLF y4/ Q E / / 1UO` _----- �` - '- 606\\\s98\- V n SWM ---- -6oz� ` - / --- - -- ! -600� v 59z, \ \ -59 S 5(o 'OUT 0 v -�59 24�r-vP 1+25 --- --- ___ \ TAP r C LE 0 -- 50� 0 25 ----�0 --- IDO / 400 jMPROY-E HALT `_---- -DRIV€wA1--------- 84 ACCESS FOR (z) LOTS �?RROPOSEDWSHAPFD GRASS-LINEDDITiH TO-. - - ` �� ` ®�- - s ( IN FEET_ B LOCATED WITHIN VDOT RIGHT-OF-WAY, AS \ ` � � - - 50 -- �• S OWN. SE Th05-SHEETTOR DE-FAIL-S. PIPE INFORMATION INLET INFORMATION ILOPE INVERT INVERT Curb SLOT ._.. ... _._ MATERIAL INLET TYPE _ ._..__ 51.78 1 2.99% 1 669.47 1 667.92 RCP 6.59 4.86% 667.82 667.50 RCP COMMENTS 17.55 10.83%1 667.50 1 665.60 RCP MI - - 673.90 VDOTSTD. IS-1 REQ'D 9.10 12.53% 663.60 662.46 RCP MI - - 672.90 VDOTSTD. IS-1 REQ'D MI - - 673.39 VDOTSTD. IS-1 REQ'D 11.84 4.56% 661.00 660.46 RCP MI - - 672.90 VDOTSTD. IS-1 REQ'D 65.65 8.73% 656.46 650.73 RCP MI - - 660.90 VDOTSTD. IS-i REQ'D 67.47 8.00% 644.73 639.33 RCP MI - - 646.00 VDOTSTD. IS-1 REQ'D 61.78 14.47% 633.33 624.39 RCP MI - - 629.10 VDOTSTD. IS-1 REaD 60.87 11.73% 618.39 611.25 RCP MI - - 615.90 VDOTSTD. IS-1 REQ'D 63.92 12.52% 605.25 597.25 RCP MI - - 601.90 VDOTSTD. IS-1 RECM 87.75 8.58% 595.25 587 72 RCP MI - - 593.50 VDOTSTD IS-1 RECM 91.28 1.51°h 587.62 58624 RCP MHA - - 591.17 VDOTSTD. IS-1 RECM 23.79 1.01% 586.14 585.90 RCP DI-3C I CG6 1 12' 1 687.85 1 VDOTSTD. IS-1 REQ'D IcXi:7FZlyk-Y§1CI+S[:Irl[3:3i[:I�:CN 9 DI-3B CC-66' 680.64 VDOT STD. IS-1 REaD 35.98 0.50% 673.65 673.47 RCP 13I-313 CG6 1 8' 1 580.80 1 VDOTSTD. IS -'I REQ'D 140.37 0.50% 1 673.37 1 672.67 1 RCP 13I-313 1 CG6 1 6' 1 680.88 1 VDOTSTD. IS-1 REQ'D 28.07 1 1.71% 1 673.82 1 673.34 1 RCP DI-3C I CG2 1 6' 1 672.88 1 VDOTSTD. IS-1 REQ'D 64.33 1 0.90% 1 668.50 1 667.92 1 RCP DI-3C I CG6 1 6' 1 674.06 1 VDOTSTD. IS-1 REQ'D 13.42 1 5.59% 1 668.25 1 667.50 1 RCP DI-3C I CG6 1 6' 1 674.10 1 VDOTSTD. IS-1 REQ'D 5.06 1 7.91% 1 667.90 1 667.50 1 RCP 24 HDPE RISER SEE DETAIL 53.94 12.78% 1 587.00 1 585.50 1 RCP Structure Area (Acres) CW to (Min.) 1 0.00 0.90 5.0 2 0.00 0.90 5.0 SWM 2 0.00 0.90 5.0 3 0.00 0.90 5.0 3A 0.00 0.90 5.0 3B 0.00 0.90 5.0 3C 0.00 0.90 5.0 3D 0.00 0.90 5.0 4 0.00 0.90 5.0 4A 0.00 0.90 5.0 SWM 1 0.00 0.90 5.0 5 0.08 0.83 5.0 5A 0.00 0.90 5.0 6 0.09 0.83 5.0 7 0.08 0.85 5.0 8 0.03 0.70 5.0 9 0.28 0.66 5.0 10 0.08 0.78 5.0 11 0.08 0.79 5.0 12 0.25 0.76 5.0 13 0.25 0.54 5.0 14 0.11 0.68 5.0 15 0.30 0.76 5.0 16 0.16 0.68 5.0 17 0.32 0.71 5.0 18 0.11 0.85 5.0 24 0.00 0.90 5.0 25 0.00 0.90 5.0 OUT 0.00 0.90 5.0 ROOF DRAIN AND YARD INLET DESCRIPTIONS Upstream Structure Type Structure Size Rim Elevation Invert Downstream Structure Rim Elevation Invert Pipe Diameter Pipe Length Pipe Material Pipe Slope Al Inlet 12" 687.50 1 685.50 1 A2 685.50 683.00 8" 63.86 HDPE 3.91% A2 Inlet 12" 685.50 1 683.00 1 STR-13 680.80 677.12 8" 19.39 HDPE 30.33% Upstream Structure Type Structure Size Rim Elevation Invert Downstream Structure Rim Elevation Invert Pipe Diameter Pipe Length Pipe Material Pipe Slope Bl Cleanout 12" 690.00 688.00 B2 689.75 686.79 8" 67.00 HDPE 1.81% 82 Cleanout 12" 689.75 686.79 B3 689.00 684.65 8" 28.98 HDPE 7.38% B3 Cleanout 12" 689.00 684.65 B4 689.40 684.33 8" 64.1 HDPE 0.50°/6 B4 Cleanout 12" 689.40 684.33 STR-12 687.85 683.96 8" 60.1 HDPE 0.62% Upstream Structure Type Structure Size Rim Elevation Invert Downstream Structure Rim Elevation Invert Pipe Diameter Pipe Length Pipe Material Pipe Slope B5 Inlet 12" 686.5 685.13 B6 688.2 684.79 8" 67.75 HDPE 0.50°/6 B6 Inlet 12" 688.2 684.79 B3 689.00 684.65 8" 28.03 HDPE 0.50% Upstream Structure Type Structure Size Rim Elevation Invert Downstream Structure Rim Elevation Invert Pipe Diameter Pipe Length Pipe Material Pipe Slope C1 Inlet 12" 688.10 686.75 C2 688.00 686.25 6" 32.25 HDPE 1.55% C2 Cleanout 12" 688.00 686.25 C3 687.25 685.7S 6" 24.44 HDPE 2.05% C3 Inlet 12" 687.25 685.75 C4 685.50 679.34 6" 50.64 HDPE 12.66% C4 Inlet 12" 685.50 679.34 STR-8 683.53 676.08 6" 83.4 HDPE 3.91% Upstream Structure Type Structure Size Rim Elevation Invert Downstream Structure Rim Elevation Invert Pipe Diameter Pipe Length Pipe Material Pipe Slope D1 Inlet 12" 683 681.5 D2 686.1 681.00 8" 23.38 HDPE 2.14% D2 Cleanout 12" 686.1 681.00 D3 682.67 680.24 8" 33.01 HDPE 2.30% D3 Inlet 12" 682.67 680.24 D4 680.10 678.00 8" 48.61 HDPE 4.61% D4 Inlet 12" 680.10 678.00 IDS 676.50 675.00 8" 44.31 HDPE 6.77% IDS Inlet 12" 676.50 675.00 1 D5A 671.00 668.86 8" 21.75 HDPE 28.23% DSA Inlet 1 12" 1 671.00 668.86 STR-17 674.06 668.35 8" 50.93 HDPE 1.00% Upstream Structure Type Structure Size Rim Elevation Invert Downstream Structure Rim Elevation Invert Pipe Diameter Pipe Length Pipe Material Pipe Slope E1 Inlet 12" 681.00 679 E2 680.25 678.00 8" 44.00 HDPE 2.27% E2 Inlet 12" 680.25 678.00 E3 678.1 676.00 8" 38.02 HDPE 5.26% E3 Inlet 12" 678.1 676.00 STR-16 672.88 668.60 8" 53.32 HDPE 13.88% Upstream Structure Type Structure Size Rim Elevation Invert Downstream Structure Rim Elevation Invert Pipe Diameter Pipe Length Pipe Material Pipe Slope 19 Inlet 24" 651.50 645.00 20 637.5 633.69 8" 122.09 HDPE 9.26% 20 Inlet 24" 637.5 632.69 21 617.5 613.55 8" 112.61 HDPE 14.33% 21 Inlet 24" 617.5 612.55 22 605.87 602.33 8" 67.01 HDPE 15.25% 22 Inlet 24" 605.87 602.23 23 600.90 596.37 8" 49.71 HDPE 11.79% 23 Cleanout 24" 600.90 596.27 23A 593.68 590.69 10" 91.35 HDPE 6.11% 23A Cleanout 24" 593.68 590.59 SWM-2 - 590.47 10" 11.82 1 HDPE 1 1.00% Q 2=1.04 ICES OL=12" V,=3.39 FPS 3 1 Q,o 1.34 CFS GRASS D,p 0.35 FT (SLOPE=5.87) DITCH 5 9 0 NO SCALE PROPOSED 12" DEEP FESCUE GRASS -LINED V-SHAPED DITCH WITH 3:1 SIDE SLOPES. PER VESCH TABLE 5-14, THE MAXIMUM PERMISSIBLE VELOCITY IS 4 ft/s 590 EXISTING GRADE 585 / 585 PROPOSED IAVON STREET EXTENDED r DITCH CENTERLINE 580 580 CONTRACTOR SHALL TIE PROPOSED AVON STREET EXTENDED DITCH INTO EXISTING DITCH & DOWNSTREAM CULV RT LOCATED AT THE SOUTHERN PROPERTY CO NER. CONTRACTOR TO TIE BACK GRADES AT 3:1. 575 CONSTRUCT ON TO BE LIMITED TO THE �5 SUBJECT PROPERTY & PUBLIC R/W, AS SHOWN. co 0 00 N 00 00 ou, co PROFILE SCALES 0+00 0+50 1+00 1+50 111 (V) 1' 50' (H) AVON ST. EXTENDED DITCH PROFILE Road Name: Avon St. Extended Roadside Ditch Ditch Side: South of Proposed Entrance Job Number: 182156 Designed By: FGM DRAINAGE AREA DESCRIPTIONS Drainage Area Area (Acres) CW Al 0.15 0.54 A2 Bl 0.14 0.90 B2 B3 B4 BS B6 C1 0.12 0.60 C2 C3 C4 D1 0.20 0.60 D2 D3 D4 DS El 0.17 0.65 E2 E3 19 0.18 0.40 20 0.15 0.50 21 0.08 0.53 22 0.33 0.41 23 0.00 0.00 23A 0.00 0.00 Checked By: SRC Sta From Sta To T (min) C Value Area (ac.) CA (accum) I' (in/hr) Q (cfs) Slope (ft/ft) Grass n=0.03 Jute Sod) (III Paved n=0.015 1 (in/hr) Q' (cfs) Depthl0 (ft Min.Design Depth & Lining Top Width (3:1 Sides) (ft) VeL I Depth VeL Depth Vel. Depth 0+00 1+25 13 0.35 0.80 0.28 3.7 1.04 0.058 3.39 fps 0.32 It 4.80 1.34 0.35 ft 12" Grass 6.00 ft Note: Proposed ditch to tie into existing loch & culvert at southern property comer. Lic. No. 035791,E L 6/17/21 40i Vl Zoa k Z w oU - F O N w m < Q i V) Z J t ■�■ Z 1Q w L Ln Z WLU > of to > i r cc O N N N CD to � A W N O) N W N Z W J J U) in 0 0 O N P-M Z Q O Q 0 D Q J � V ' Q . cro I..L 0- W Z 0 O Q Z' I I Q Q 0 w a � JOB NO. 112066 SCALE \S SHON SHEET NO. 13 INLETS ON GRADE, DESIGN (CURB SPREAD AND INLET CAPTURE) Intensity 4.00 (Intensity is 4 in/hr for spread, and 6.5 in/hr for capacity and depth) Mannin s Coefficient, n is 0.013 Inlet Hydrology Curb and Gutter Inlet 3 � d n a o j x rn v C LN _ N 42 b NLN +NU. O U N 0 .� U % W Q 4) C U O Q 3 N LU C Q _T 4l OI U P (n YO rp O C i C l� K J Y C O t? O� O U U N J m Q N II N N U U b j C E a 'a0 o o > � d c5 cai ci of 0) 3 0)) U)i- w° I A 7n W :�i :1 w A 5 3B 6.0 0.08 0.83 0.066 0.27 0.13 0.40 0.0619 0.0200 2.0 0.0830 4.1500 3.36 0.99 3.5120 0.1463 0.1649 6.60 0.91 0.99 0.39 0.01I 6 3B 6.0 0.09 0.83 0.075 0.30 0.00 0.30 0.0619 0.0200 2.0 0.0830 4.1500 3.01 0.99 3.5120 0.1463 0.1649 5.84 1.03 1.00 0.30 0.007 3B 6.0 0.08 0.85 0,068 0.27 0.00 0.27 0,0480 0,0200 2.0 0.0830 4.1500 3.05 0.92 3.5120 0.1463 0.1546 5.41 1.11 1.00 0.27 0.008 3B 6.0 0.03 0.70 0.021 0.08 0.00 0.08 0.0380 0.0200 2.0 0.0830 4.1500 2.05 1.00 3.5120 0.1463 0.1663 2.95 2.04 1.00 0.08 0.0010 3B 6.0 0.08 0.78 0.062 0.25 0.00 0.25 0.0490 0.0200 2.0 0.0830 4.1500 2.94 0.99 3.5120 0.1463 0.1649 5.05 1.19 1.00 0.25 0.0015 3B 6.0 0.30 0.76 0.228 0.91 0.00 0.91 0.0480 0.0200 2.0 0.0830 4.1500 4.80 0.89 3.5120 0.1463 0.1502 9.15 0.66 0.85 0.78 0.1313 3B 8.0 0.25 0.54 0.135 0.54 0.00 0.54 0.0159 0.0200 2.0 0.0830 4.1500 4.85 0.90 3.5120 0.1463 0.1517 5.24 1.53 1.00 0.54 0.0014 3B 6.0 0.11 0.68 0.075 0.30 0.00 0.30 0.0159 0.0200 2.0 0.0830 4.1500 3.89 0.95 3.5120 0.1463 0.1590 3.97 1.511.00 0.30 0.00 - for inlets draining to stormwater management facilities, where overland flow to facilities is not available, 100% capture is required at 6.5in/hr INLETS ON GRADE, DESIGN (CURB SPREAD AND INLET CAPTURE) Intensity 6.50 (Intensity is 4 in/hr for spread, and 6.5 in/hr for capacity and depth) Mannin s Coefficient, n is 0.013 Inlet Hydrology Curb and Gutter Inlet U a1 O O O C N N U ? a N N O V rn 16 d E X �S` W 2N N C o. 3 U o 3 'L-' C y0 N c Q ` Q'� O nl •� fp Q O ca L .2 O m cn N C S E a _ ¢ (5 U C7 (7 O ai m � in Co 1= w° 6 in rn E .� ui O O c10, IY 5 3B 6.0 0.08 0.83 0.066 0.43 0.40 0.83 0.0619 0.0200 2.0 0.0830 4.1500 4.42 0.92 3.5120 0.1463 0.1546 9.32 0.64 0.84 0.70 0.13 18 6 3B 6.0 0.09 0.83 0.075 0.49 0.00 0.49 0.0619 0,0200 2.0 0.0830 4.1500 3.62 0.97 3.5120 0. 1463 0.1619 7.27 0.83 0.96 0.47 0.02 17 7 3B 6.0 0.08 0.85 0.068 0.44 0.00 0.44 0.0480 0.0200 2.0 0.0830 4.1500 3.66 0.97 3.5120 0.1463 0.1619 6.45 0.93 0.99 0.44 0.00 - 8 3B 6.0 0.03 0.70 0.021 0.14 0.00 0.14 0.0380 0.0200 2.0 0.0830 4.1500 2.46 1.00 3.5120 0.1463 0.1663 3.61 1.66 1.00 0.14 0.00 - 10 3B 6.0 0.08 0.78 0.062 0A1 0.00 0.41 0.0490 0.0200 2.0 0.0830 4.1500 3.53 0.98 3.5120 0. 1463 0.1634 6.23 0.96 1.00 0.41 0.00 - 15 3B 6.0 0.30 0.76 0.228 1.48 0.00 1.48 0.0480 0.0200 2.0 0.0830 4.1500 5.76 0.84 3.5120 0.1463 0.1429 11.56 0.52 0.73 1.09 0.40 5 13 3B 8.0 0.25 0.54 0.135 0.88 0.00 0.88 0.0159 0.0200 2.0 0.0830 4.1500 5.82 0.84 3.5120 0.1463 0.1429 6.66 1.20 1.00 0.88 0.00 5 14 3B 6.0 0.11 0.68 0.075 0.49 0.00 0.49 0.0159 0.0200 2.0 0.0830 4.1500 4.66 0.90 3.5120 0.1463 0.1517 5.01 1.20 1.00 0.49 0.00 5 - for inlets draining to stormwater management facilities, where overland flow to facilities is not available, 100%9 capture is required at 6.5in/hr Desial Year: 10 Proiect: Avon Park II 0617fi 13PAW Prepared bv: LMW. PE • • • I 1 ® 1 1 1 111 111 ��_---_--____-- _-_-_--____-- INLETS IN SUMP, DESIGN (CURB SPREAD AND INLET SPREAD AND DEPTH) Intensity 4.00 (Intensity is 4 in/hr for spread, and 6.5 in/hr for capacity and depth) Mannin s Coefficient, n is 0.013 Inlet Hydrology Curb and Gutter Inlet 3 2 a, m 8. N N C 6 w 2 @ 4i a d `s $ F o I] Q 3 E w 6 > 1 Q U U O O O W N ?i N all 1 0.28 1 0.66 10.1851 0.74 0.00F0.74 0.0010 0,0200 2.0 0,0830 4.1500 9A7 0.62 STIR 9 DI-3A 4.0 combined flowall 0.08 0.79 0.063 0.25 0.00 0.0010 0.0300 2.0 0.0830 2.7667 4.76 0.84 STIR 11 DI-3C 6.0 combined flowall o25 0.76 0,190 0.76 0,0007 0 0.0100 2.0 0.0830 8,3000 14,29 0,54 STIR 12 DI-3C 1 12.0 combined flow 0.8 0.09 0.199 9.12 all 0.16 0a8 0.109 o.44 0.00 0.44 1 0.0010 o.01so 2.0 0.0830 4.3664 7.76 0.70 1 1 SIR 16 F D1-3C 6.0 combined flow 0.4 0.10 0.278 5.25 all 0.32 1 0.71 1 0.227 0.91 0.00 0.91 0.0010 1 0.0500 1 2.0 1 0.0830 1.6600 5.59 0.73 STR 77 DI-3C 6.0 combined flow 0.9 0.11 0.236 2.17 all 0.11 1 0.85 0.094 0.37 0.01 0.38 0.0010 1 0.0500 1 2.0 1 0.0830 1 1a800 4.01 0.87 Carryover from STR-5 STR 18 7131-3C 6.0 combined flow 0.4 0.09 0.199 1 1.82 * gutter longitudinal slope of 0.001 should be used in a sump condition - grate inlets (DI-7) in open pavement areas will not have a curb spread, but will have inlet spread and depth - for inlets draining to stornmater management facilities, the 6.5in/hr check storm will suffice for the 10yr conveyance to the facilities NOTE: Inlet size for structures determined by overland flow. Pipes have been sized to include overland flow as well as yard inlet and roof drain drainage areas Design Storm Year = 10 INLETS IN SUMP, DESIGN (CURB SPREAD AND INLET SPREAD AND DEPTH) Intensity 6.50 (Intensity is 4 in/hr for spread, and 6.5 in/hr for capacity and depth) Mannin s Coefficient, n is 0.013 Inlet Hydrology Curb and Gutter Inlet 3 � g` b yp C v is c s N y c 2 z X N e r s t d c J 0 q 2 c 2 c .�-� 0 m 8 6 5 c m .y. 5 w X o. 2 v 'L .r ' M m _ w 4 w L O a O > 1 < ci Q .0 U d a & ui X ro 3 %i w %i ro f O W o a � all 0.28 0.86 0.785 7.20 0.00 1.20 0.0010 0.0200 2.0 0.0830 4.7500 11.00 0.52 STIR9 F DI-3A 4.0 combined flow 1.2 0.26 0,562 12.87 all 0.08 1 0.79 0.063 1 0.41 1 0.00 0.41 0.0010 0.0300 1 2.0 1 0.0830 1 2.7667 1 5.71 0.79 STR 11 DI-3C 6.0 combined flow 0.4 0.10 0.210 3.20 all 0.25 0.76 0.190 1.24 0.00 1.24 0.0010 O.OIDO 2.0 0.0830 8.3000 17.14 0.43 STR 12 DI-3C 12.0 combined flow 1.2 0.13 0.275 12.60 all 0.16 0.88 0.709 0.71 1 0.00 0.71 0.0010 0.0190 2.0 0.0830 4.3684 9.37 1 0.60 STR 16 DOC 6.0 combined flow 0.7 0.14 0,301 7.26 all 1 0.32 1 0.71 0.2271 1.48 1 0.02 1.50 0.0010 1 0.0500 1 2.0 0.0830 1.6600 6.70 0.54 Carryover from STR-6 STIR 17 DI-3C 6.0 combined flow 1.5 0,15 0.327 3.00 all 1 0.11 1 OM10.0941 0.61 1 0.13 0.74 0.0010 0.0500 2.0 0.0830 1.6600 4.81 0.79 Carryover from STR-5STR 18 0I-3C 6.0 combined flowl 0.7 1 0.14 1 0.31.0 1 2.84 * gutter longitudinal slope of 0.001 should be used in a sump condition - grate inlets (DI-7) in open pavement areas will not have a curb spread, but will have inlet spread and depth - for inlets draining to stormwater management facilities, the 6.5in/hr check storm will suffice for the 10yr conveyance to the facilities NOTE: Inlet size for structures determined by overland flow. Pipes have been sized to include overland flow as well as yard inlet and roof drain drainage areas ` �- 1 11 1 • 1 1 11 ����--_-_-_- ®- 1 1 1 1• 1 1 1 1 1 1 1 1 1 • r--_-_-_- 0- 1 1 1 1` 1 1 1 1 1 1 1 � • r• �--_-_-_- ®- 1 1 1 1• 1 1 1 1 11 1 � • r �--_-_-_- �- 1 1 1 1• 1 1 1 1 11 1 � • r �--_-_-_- �- 1 11 1• 1 1 11 1 11 ���--_-_-_- -� 1•: 1 1 1 1 1 1 • r �--_-_-_- 1 1: 1 1 1 1 11 • r ®- 1 1 1 1• 1 1 1 1 1 1 � • r �--_-_-_- •• N N z w 0 V r ZI- Z z/A zw WW Zz Z Q x Q Z O oo0� �co U) � Q =O Z Z /w V O O 1J 0 F 1 W W ^> J J j .Z W Q Q W wLU amm o� Q Q Ce W c. c. d p d a W C- w > > ce � 0 0 0 N N W N N N Q . 1 O .\-I O\ N N %D 0 Z� r CM M M N M N WCD CY) N W N z Q U-)LU _ z O U) Q Q J 0 o"o D O V Zcl� ' Q Q V U Y W W Y � Q z Ul U z � w O o Z Lu Q (n LU ON F- w a U) JOB NO. 112066 3.11 _ 501 14 IT1 ITl (I) V) 0 0 0 0 0 0 �;7 �7 ITl ITl ITl DO DO D �T1 0 0 RO o RO cP 0 0 +o Z +o D 0 D O �, co D � D rri D D 0 O m�� c+n 71 71 FF�-, o o N N z + z + O o o � o N N n r ^� O ^m o w — w 0 0 +o z O z O 00 w � w cn w o = o +O O O �—O J J D o D � z z c� c� r�1 71 0 0 T1 Tl F— F— � � 0 0 � -1-1 F— F— r� � N a O C N N O C-2 CIO � y � a � z � � 'TJ a C� a a L" t�7 ti a a REVISIONS COLLINS ENGINEERING DATE REVISION DESCRIPTION �b C�'"� CIO AL SUBMITTAL0� o 200 GARRETT STREET, SUITE K.-CHARLOTTESVILLE, VA 22902-434.293.3719 11/13% 0 REVISED P/16/20 IERACSA COMMENTS a o PROJECT 12/03/20 REVISED PER ALBEMARLE COUNTY AND VDOT COMMENTS r a CUD Ln F? �` 2/11/21 REVISED PER ALBEMARLE COUNTY COMMENTS DATED 1/8/21 II 9 NO z AVO N PARK II — ROAD PLAN 6/17/21 REVISED PER ALBEMARLE COUNTY COMMENTS DATED 1/8/21 0 m M° SHEET INTERSECTION SIGHT DISTANCE PROFILES o crl o crl W � o cn wo 689.7 �, 686.00 p 6go.z �y 683.95 m � 68g.8 'cWj, � 68z.i3 - 6go.3 A I V1 O I x u, � m C 68i.88 � I Z � m A � D < O � I 6go.6 � � 68i.oy x G z 68i.8 �_ 679.gi I m ti 678.8 Z � m= II � ti a 0 678.z m� I W O TI o cn o cn o cn cP o cn o cP m� o cP o �o w 689.7 in 686.00 6gi.g ��ti 683.8g � /n 693 5 � O 683.zz I v A I 693.7 � � x 68y.io � x O I � z � � A r Z � A I m 6gy.i m � � � 68z.3z � � I 685.5 I — 680.00 1 O 679.6 n n' N 0 678.8 m � / f These plans and associated documents are the exclusive property of COLLINS ENGINEERING and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but not limited to construction, bidding, and/or construction staking without the express written consent of COLLINS ENGINEERING County of Albemarle Conservation Plan Checklist - To be placed on Landscape Plans (Handbook, pp W-233-111-297 mr complete specifications) L The follo ams, Items shag be shown on the plan: ZI Treas to be saved; KI Limits ofcleming (ourside dripline of trees to be saved); KI Locatlonand type ofprotective fencing; ® Grade changes requiring tree wells or walls; Proposed trenching or amassing beyond the limits of cleming. 2. Markin a: I] All [sees to be saved shall be marked with print or blean at a height clearly visible to equipmerd operators. 93 No grading shall begin until the tree marking has been inspected and approved by a County Inspector. 3. Pre-0ourtruction Conference: SJ Tree preservation and protection measures shag be reviewed with the couhactor on site 4. Eaulsment Oranationand Stomas: Heavy equipment, vehicular trzHic and storage of construction materials including soil shag not be pe ra tted within the driplinee of treas to be saved. S. Soil Foods. and Stormwater Detendun Devices: Q Such devices shall not adversely affect trees robe saved. 6. Fires: UPies are not permitted within 100 feet ofthe dripline of trees to be saved. 7. T"ic Materials: ® Toxicmabands shall not be stored within 100 feet ofthe dripline of tress to be aaved. S. Protective Fenctne: LI Trees to be retained within 40 feet of a proposed building or activity shell be tented b forcing. Pr P g gig t5' Pro' Y 8 0 Fina shall be m lace and shall be iva ectad and a owed b a Co Irvs actor 'or to mrsstructirn n6 P P PPr Y wtY P Prr ��m' 9. free Wells: El When the ground level most be raised widdn the ddplins ofatree to be saved, atree well shall be provided and a construction detail submitted for approval. 14. To. Walls: LI When the ground level must he lowered within the dripline a tresto be saved, a tree wag shall be provided; and a construction detail suboutted for approval. 11. Trenchins and Tennelinu: 0 Whin trenching is required within the Emits of clearing, it shall be done a, far away from the trunks of trees as possible. Tunneling under a large tree shag be considered as an alternative whanit is anticipated that necessarytrerchng will destroy fesder roots. 12. Cl=anal_ ® Protective fencing shall be the feet items removed during the final clearmp. 13. Dammeed Tress: Al Damaged trees steal/ll//treated immediately by pmrdn& fertilization or other methods recommended by at" specialist. DOTE: Ii IS THE DEVOPER'S RESPONSIBILITY TO CONFER WITH THE CONTRACTOR ON TREE CONSERVATION REQUIREMENTS. CONTRACT PURCHASER SIGNATURE (DA"1'E) 6(1/06 Pape 1 of CONSERVATION PLAN NOTES: - 1.ALL TREES TO BE PRESERVED AND PROTECTED SHALL BE MARKED WITH PAINT OR RIBBON AT A HEIGHT CLEARLY VISIBLE TO EQUIPMENT OPERATORS. NO LAND DISTURBING ACTIVITY SHALL BEGIN UNTIL THE TREE MARKING HAS BEEN INSTALLED BY THE NOTE: ALL LANDSCAPING EASEMENTS, BUFFERS, AND SCREENING CONTRACTOR AND INSPECTED AND APPROVED BY THE COUNTY ENGINEERING DEPARTMENT. SHALL BE PLANTED IN ACCORDANCE WITH THE APPROVED PROFFERS. 2. HEAVY EQUIPMENT, VEHICULAR TRAFFIC, AND THE STORAGE OF CONSTRUCTION LANDSCAPING SHALL BE INSTALLED PRIOR TO THE FIRST MATERIALS AND SOIL SHALL NOT BE PERMITTED WITHIN THE OUTSIDE DRIPLINE OF TREES CERTIFICATE To BE PRESERVED AND PROTECTED. OF OCCUPANCY FOR ANY PROPOSED UNITS WITHIN THE 3. TEMPORARY EROSION CONTROL MEASURED AND/OR PERMANENT STORMWATER DEVELOPMENT AS DETAILED IN PROFFER 3. MANAGEMENT FACILITIES LOCATIONS SHALL BE COORDINATED SUCH THAT THEY SHALL NOT ADVERSELY AFFECT TREES TO BE PRESERVED AND PROTECTED. 4. ro BE SHALL R ED AND PROTECTED. 100 FEET of THE ourslDE DRIPLINE of TREES NOTE: SCRIM FENCING TO BE INSTALLED IMMEDIATELY FOLLOWING 5. TOXIC MATERIALS SHALL NOT BE STORED WITHIN 100 FEET OF THE ourslDE DRIPLINE OF GRADING IN THE LOCATION WHERE THE SCRIM FENCE IS TO BE TREES TO BE PRESERVED AND PROTECTED. LOCATED. 6. NO LAND DISTURBING ACTIVITY SHALL BEGIN UNTIL THE TREE PROTECTIVE FENCING HAS - BEEN INSTALLED BY THE CONTRACTOR AND INSPECTED AND APPROVED BY THE COUNTY I / ENGINEERING DEPARTMENT. % LANDSCAPING NOTES: 7. WHEN TRENCHING FOR ANY KIND of UNDERGROUND WATER, SEWER, ELECTRICAL, CABLE, 1. STREETTREES PROVIDED So' O.C. AND 5'-io' FROM PROPOSED UTILITIES. TELEPHONE OR OTHER UTILITY SERVICE IS NECESSARY WITHIN THE LIMITS OF TREE 2. ALL SITE PLANTINGS OF TREES AND SHRUBS SHALL BE ALLOWED TO REACH, AND BE PROTECTION OR BEYOND THE LIMITS OF CLEARING, THE SEPARATION FROM THE TRUNKS OF TREES SHALL BE MAXIMIZED TO THE FURTHEST EXTENT POSSIBLE. TUNNELING SHALL MAINTAINED AT, MATURE HEIGHT; THE TOPPING OF TREES IS PROHIBITED. SHRUBS BE REQUIRED WHEN DEEMED, BY THE COUNTY ENGINEER, THAT TRENCHING WILL AND TREES SHALL BE PRUNED MINIMALLY AND ONLY TO SUPPORT THE OVERALL SIGNIFICANTLY DAMAGE FEEDER ROOTS OF TREES TO BE PRESERVED AND PROTECTED. HEALTH OF THE PLANT. 8. ANY DAMAGE TO THE CROWN, TRUNK, OR ROOT SYSTEM OF ANY TREE TO BE 3. TOTAL STREET FRONTAGE = 964' PRESERVED AND PROTECTED SHALL BE REPAIRED IMMEDIATELY, IN ACCORDANCE WITH REQUIRED STREET TREES: 21(1TREE PER EVERY 5o'OFSTREET FRONTAGE) THE PRACTICES IN THE EROSION AND SEDIMENT CONTROL HANDBOOK. CARE FOR SERIOUS PROPOSED STREET TREES:23 INJURIES SHALL BE PRESCRIBED BY A PROFESSIONAL FORESTER OR TREE SPECIALIST. NOTE: 278'OF STREET FRONTAGE ALONG HATHAWAY STREET 9. SOILS WHICH HAVE BEEN COMPACTED, OVER THE ROOT ZONES of TREES To BE REQUIRED STREET TREES: 6 PRESERVED AND PROTECTED, SHALL BE AERATED BY PUNCHING HOLES WITH AN IRON PROPOSED STREET TREES: 8 BAR EVERY 18" OVER THE ROOT ZONE. THE BAR SHALL BE DRIVEN 12" DEEP AND NOTE: 382'OF STREET FRONTAGE ALONG DESOTO DRIVE MOVED BACK AND FORTH IN EACH HOLE UNTIL SOIL IS LOOSENED. REQUIRED STREET TREES: 8 10. TREE PROTECTIVE MEASURES SHALL BE THE LAST OF THE TEMPORARY EROSION PROPOSED STREET TREES: 6 CONTROL PLAN MEASURES REMOVED DURING THE FINAL CLEAN-UP. NOTE: zoo' OF STREET FRONTAGE ALONG ANOKO COURT REQUIRED STREET TREES: 4 PROPOSED STREET TREES: 4 NOTE: 104' OF STREET FRONTAGE ALONG PRIVATE ROAD REQUIRED STREET TREES: 3 PROPOSED STREET TREES: 5 4. PARKING LANDSCAPE REQUIREMENTS \ REQUIRED PARKING LANDSCAPING = 21 PARKING SPACES @ i TREE / io SPACES 3 TREES REQUIRED El TOTAL TRESS PROVIDED ADJACENT TO PARKING SPACES = 3 TREES PROVIDED W =- -5. SEE SHEET 6A FOR TREE PLANTING & STAKING AND TREE FENCING & ARMORING o DETAILS. v v STREET TREES LANDSCAPING PLANT SCHEDULE PROPOSED 20' DRAINAGE AND LANDSCAPING EASEMENT (LANDSCAPED BUFFER AREA) NOTE: IF TREES RE LOCATED WITHIN 5' OR LESS QFTHE PROPERTY LINES ADJACENT TO T"oF-Az, TMPgoF--F--42, TM'Pgo_F-F-43�R I TMPgoF-F-44, T E DEVELOPER SHALL REMOVE THE TREES ON THE ADJACENT PRO ERTIES: THE REMOVAL OF S WILL BE o SUBJECT TO TH EXISTING PROPERTY OW ER'S WRI N APPROVAL. ACSA PROPOSED 0. WATER SCRIM FENCE o m LANDSCAPING WITHIN 15' FENCE h LANDSCAPE BUFFER THAT TANKALONG 0. v ABUTS ACSA WATER TANK _ ! TMP -A2 PROPER Y F q PROPERTY SHALL HAVE NIF ALBEMARLE COUNTY LINE SIMILAR LANDSCAPING TO SERVICE AUTHORITY WHAT WAS PLANTED WITH DR; 3571 PG 977 THE LATEST AVON PARK PROPOSED 15' LANDSCAPING STORAGE TANK SECURITY EASEMENT (LANDSCAPED PROPO 3.0, FENCE IMPROVEMENTS PLAN BUFFER AREA) PROPOSED DB.PG. CG-2 CURB S58°48'09"E 114.92' % LANDSCAPE_ EASEMENT DB._PG._ h w 2 i q 0 C�o �ct- I q � 2 �O N 0. N ti 00 0 U �o I 2 PROPOSED PRIVATE ACCESS EASEMENT I .Z:111111111111101 5' REAR SETBAC 2o' GRADING EASEMENT DB.3291 PG.607 COco 9 0.� cl 2 rn Uf2 Iq h T SYM BOTANICAL COMMONNAME SIZE CANOPY(SF) TOTALSITE QUANTITY COVERAGE (SF) AR ACER RUBRUM RED MAPLE 13/4" 397 14 5,558 UA ULMUSAMERICANA AMERICAN ELM 13/4" 397 12 4,764 LXIS�ING28' I AREA OF PROPOSED ONSITE I 2o' GRADING EASEMENT LANDSCAPE BUFFER I I DB. 3291 PG. 607 EXISTING 32' F/C - F/C I TMP 90E-7 I TMP 90E-9 NIF IAN FARIS O'CONNOR LIVING TMP 90E-8 DB 4163 PG 261 TRUST NIF IGNACIO 0 DB 5116 PG 289 TARA L DE _ CARDENAS I DB 4060 PC 77 PROPOSED 10' PROPOSED SCRIM FENCE S LANDSCAPING FENCE ALONG PROPERTY LINE I EASEMENT ADJACENT TO TMP goF-Ai DB.PG. PROPOSED 2o' DRAINAGE AND LANDSCAPING EASEMENT (LANDSCAPED BUFFER AREA) DB.PG. ` S58° '07' E 485 78' oc VPROPOSED 2o'LANDSCAPINGEASEMENT -NATURAL IA LANDSCAPED AREA OR REPLANTING/NEW LANDSCAPED BUFFER FOR ANY DISTURBED AREAS DB.PG. m 260 / - --- PROPOSED 20' S i m EMERGENCYACCESS - - - ♦ EASEMENT DB. \\ T s I \ \ CONCRETE LOT 30 \ 37,445 0.86 ACRES ASPHALT Q I CONC ETE I CD 00 TMP 90-30B NIF JOMN A OR RUBr T BROOKS DB 1191 PG' 396 PROPOSED5' LANDSCAPING COMMUNITY EASEMENT ASSOCIATION INC CIO DB.PG. REAL PROPERTY INC DB 3692 PG 319 - I LOT LOT LOT LOT I �. LOT LOT LOT LOT L28 OT LOT ,40 3 1 1 7 *25 3 �, LOT -� -- - T�I DESOTO DRIVE 10' F Trl \ \ 6 I IF _ (4) UA STREET \ I I I k 12'xi8' ASPHALT � fn - [F TREES ALONG RONT SETBACK k v \ \ I LOT X I DRIVEWAY (MIN.) c d \ 7 STOP SIGN (TYP.) 1� \ - r.., _. 2 1 .� °02'03"W 3.10' LOCATION OF PROPOSED DETENTION BASIN PLANTER /IMPROVED ASPHALT DRIVEWAY ACCESS FOR (2) LOTS Lic. No. 035791,E 6/17/21 40i Z O ¢ k z Z w E oU C - F O U w to � � Q C 0 J ( Z O .Q F- w t U1 Z w > ° to ' i ` �W/ cc \ o 0 0 o � C O\l ti ti N to L9 LANDSCAPED BUFFER FOR ANY 4 I DISTURBED AREAS , OPEN SPACE 5.262 AC / AREA B 229,211 SF�' / � I 0 / -� EXISTING GRAVEL y DRIVEWAY TO BE i IMPROVED TO AN I LOT v I 1 BRIG - ASPHALT DRIVEWAY I 8 W �� + E,, x i is i, zv - - - - - S'CONRETE , PROPOSED �� � � � � � W � �I �� TO SERVE LOTS 29 SIDESETBACK SIDEWALK DE T� DRIVE N h DESOTO IYE 1 GUARDRAIL LOT29 AND3o I I 5 -- --- - - - - -- -- I �) 1 ', � 1 I NOTE: SLOPE OF 40,02o SF 49' PF ATE RN' s. fa 49' PRIVATE R W 1 = - I (TYP MAILBOX _ � / � 1 �� 1 / / � EMERGENCYACCESS 0.92ACRES I KIOSK `, : i! - -- ROAD SHALL NOT I I I LOT a ♦ s �; `, 'ice 'i. ,I x 1 (� �' �+ EXCEED 16% I I 9 O �,h, �► CONCRETE PROPOSED 20' 1 A. EMERGENCY ACCESS I i ON S TBA ! s r' o'. RON ACK \, A. EASEMENT LOT Y o (4) AR (STREET - I _ #19 6 8 DB.PG. /I I 0 3 STREET SIGN (TYP.) / \ PROPOSED 12' _ / �o - - QI I- -I �r 1-% CONC ETE • m TREES ALONG Ln DESOTO DRIVE V A ASPHALT EMERGENCY. i� 7 Oil \ ACCESS ROAD / 11 LOT I � -1 I --- LOT LOT LOT LOT( LOT LOT LOT LOT LOT LOT O 3 5 \ --' * 7 ig 2i 1 1 � 1 18 * 20 � + I PROPOSED 4j PRIVATE � - _� - -- _ � � GRAVEL � LOT ACCESS EASEMENT - _- - - - - - 12 DB. PG. - - - - ----- ETBAE 10 REAR ETBAC - - - - - - - -PROPOSED G- 7--Tr P EDC 6CURB NO PARKING (2)UASTREET OPEN SPACE (3)ARSTREET (2)UASTREET SIGN(TYPJ N59°18'07"W 1,072.99'(T) TREES ALONG NO PARKING TREES ALONG TREES ALONG AREA A: 7,334 SF SIGN (TYP.) HATHAWAY DESOTO COURT PROPOSED io' LANDSCAPING ANOKO COURT STREET EASEMENT (LANDSCAPED _______ (4) AR STREET PROPOSED io' LANDSCAPING (3) AR STREET BUFFER AREA) PROPOSED DOUBLE -SIDED EASEMENT (LANDSCAPED (4) UA STREET TREES ALONG DB.PG. Z ti M M PROPOS N LANDSC LANDSC 4 DB. � 1 20 N O Cn N -- i LU LU L9 CONCRET O � z<j Q LOTS _ 374� U o.86 ACRES 1 ►d1 Uj in LU ZLU V) TREES ALONG TREES ALONG DESOTO COURT VERTICAL FENCING (BOARD BUFFER AREA) ANOKO COURT TMP 90-30 ON BOARD) PRIVACY FENCE DB.PG. ' HATHAWAY (INCL. PARKING) (INCL. PARKING) N/F CARY D BROOKS JR ' STREET TMP 90-30B DB 4858 PC 406 / PROPOSED 3 BOARD FARM NIF JOHN A OR RUBY T BROOKS' FENCE ALONG PROPERTY LINE DB 1191 PG 396 - NOTE: ALL STREETS WITHIN THE DEVELOPMENT SHALL BE MARKED WITH NO PARKING SIGNS ON BOTH SIDES OF THE ROADWAY. HATHAWAY STREET SHALL BE MARKED WITH NO PARKING SIGNS ON ONE SIDE OF THE ROADWAY. TMP 90-30A NOTE: (*) DENOTES THE LOCATI WITHIN THE DEVELOPMENT. PE AFFORDABLE HOUSING UNITS WITHIN N OF THE AFFORDABLE UNIT PROFFER #1, THERE SHALL BE (6) THE DEVELOPMENT. NIF CARY D OR MYRTLE T BROOKS DB 1191 PG 396 �_j 30 GRAPHIC SCALE 0 0 30 60 121 i ( IN FEET ) 1 inch - 30 ft. C3 0 w a in JOB NO. 112066 11 SCALE OI =3 SHEET NO. 16