HomeMy WebLinkAboutWPO202100025 Approval - County 2021-08-05�h� os .arrJ COUNTY OF ALBEMARLE
Department of Community Development
401 McIntire Road, North Wing
Charlottesville, Virginia 22902-4596
Tel. (434)296-5832 * Fax (434) 972-4126
'Imr}r
Stormwater Pollution Prevention Plan (SWPPP)
For Construction Activities At:
Project Name: BUNDORAN FARM - TMP 86-38
Address:
Bundoran Farm, Lot A-9
North Garden, VA 22959
Prepared by:
Name: ROUDABUSH, GALE & ASSOC., INC.
Prepared for:
Name: DOUGLASS L. KARCZEWSKI (Owner)
Bramante Homes- Christopher Brement (Operator)
SWPPP Preparation Date: APRIL 19, 2021
APPROVED
by the Albemarle County
Commugitvs �yIejopment Department
Date /
Pit. WrvzvL1VvvLi
(This document is to be made publicly available according to 9VAC25-880-70, Part II, section D)
Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County
CONTENTS: (from Albemarle County Code Sec. 17-405)
1. Registration statement
2. Notice of general permit coverage
3. Nature of activity
4. Erosion and Sediment Control Plan.
5. Stormwater Management Plan
6. Pollution Prevention Plan.
7. Discharges to impaired waters, surface waters within an applicable TMDL
wasteload allocation, and exceptional waters.
8. Qualified personnel
9. Signed Certification
10. Delegation of authority.
11. General permit copy
12. Inspection logs
13. Additional Information
Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County
Section 1. Registration statement
(Provide a signed completed copy of the DEQ registration statement)
Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County
VIRGINIA DEPARTMENT OF ENVIRONMENTAL QUALITY
GENERAL VPDES PERMIT FOR DISCHARGES OF STORMWATER FROM
CONSTRUCTION ACTIVITIES (VAR10)
REGISTRATION STATEMENT 2019
Application type. x❑ NEW PERMIT ISSUANCE
(CHOOSE ONE) ❑ MODIFICATION WITH ACREAGE INCREASE
❑ MODIFICATION WITHOUT ACREAGE INCREASE
❑ EXISTING PERMIT RE -ISSUANCE
Section I. Operator/Permittee Information.
PERMIT #:
PLAN/ID #:
TECHNICAL CRITERIA: 116 ❑ IIC ❑
A. Construction Activity Operator (Permittee). The person or entity that is applying for permit coverage and will have
operational control over construction activities to ensure compliance with the general permit. A person with
signatory authority for this operator must sign the certification in Section V. (per Part III. K. of the VAR10 Permit).
Operator Name:
Bramante Homes
Contact person:
Christopher Brement
Address:
506 Locust Ave.
City, State and Zip Code:
Charlottesville, VA 22902
Phone Number:
434-202-8500
Primary and CC Email:
christopher@bramantehomes.com dgreene@roudabush.com
B. Electronic correspondence. To receive an emailed coverage letter or to pay by credit card, you must choose YES
and include a valid email. May we transmit correspondence electronically? YES ® NO ❑
Section n. construction Activity Information.
A.
Include a site map showing the location of the existing or proposed land -disturbing activities, the limits of land
disturbance, construction entrances and all waterbodies receiving stormwater discharges from the site.
B.
Project site location information.
Construction Activity Name:
Bundoran Farms TMP 86-38
Address:
Bundoran Farm Lot A-9
City and/or County and Zip Code:
North Garden VA 22959
Construction Activity Entrance Location
(description, street address and/or
latitude/longitude in decimal degrees):
37.990128,-78.674692
Latitude and Longitude
(6-digit, decimal degrees format):
37.990128,-78.674692
C.
Acreage totals for all land -disturbing activities to be included under this permit coverage. Report to the nearest
one -hundredth of an acre.
Total land area of development (include entire area to be
disturbed as approved in the Stormwater Management Plan):
23.64 ac
Primary estimated area to be disturbed (include portions with
Erosion and Sediment Control Plan approval only):
1.96 ac
Off -site estimated area to be disturbed (if applicable):
N/A
D.
Property Owner Status:
FEDERAL ❑ STATE ❑ PUBLIC ❑ PRIVATE
E.
Nature of the Construction Activity Description (i.e. commercial,
industrial, residential, agricultural, environmental, utility):
Residential
F.
Municipal Separate Storm Sewer System (MS4) name(s) (if the
site is discharging to a MS4):
N/A
G.
Estimated Project Dates (MM/DD/YYYY).
Start Date:
4111 I ZO L4
Completion Date:
911 J Z bL1
H.
Is this construction activity part of a larger common plan of
development or sale?
YES ❑ NO
Rev 11/2020 PAGE 1 16
CONSTRUCTION GENERAL PERMIT (VAR10) REGISTRATION STATEMENT 2019
I. 61h Order Hydrologic Unit Code (HUC) and Receiving Water Name(s). Include additional areas on a separate page.
HUC
NAMES) OF RECEIVING WATERBODY
020802031201 JM46
North Fork Hardware River
Section III. Off -site Support Activitv Location Information.
List all off -site support activities and excavated material disposal areas being utilized for this project. Include additional
areas on a separate page.
Off -site Activity Name:
Address:
City or County:
Off -site Activity Entrance Location (description, street
address and/or latitude/longitude in decimal degrees):
Latitude and Longitude (6-digit, decimal degrees format):
Is this off -site activity an excavated material disposal
area?
YES ❑ NO ❑
If this off -site activity is an excavated material disposal
area, list the contents of the excavated fill material:
Will a separate VPDES permit cover this off -site activity?
YES ❑ NO ❑
Section IV. Other Information.
A.
A stormwater pollution prevention plan (SWPPP) must be prepared in accordance with the requirements of the
General VPDES Permit for Discharges of Stormwater from Construction Activities prior to submittingthe
Registration Statement. By signing the Registration Statement, the operator is certifying that the SWPPP has been
prepared.
B.
Has an Erosion and Sediment Control Plan been
submitted to the VESC Authority for review?
YES ® NO ❑
Erosion and Sediment Control Plan Approval Date (for
the estimated area to be disturbed MM/DD/YYYY):
C.
Has land -disturbance commenced?
YES ❑ NO ❑x
D.
Annual Standards and Specifications. If this project is utilizing approved Annual Standards and Specifications
(AS&S), attached the completed AS&S Entity Form.
AS&S Entity Name (if different from the Operator
identified in Section 1):
E.
Billing information (leave blank if same as the Operator identified in Section I. above). This entity will receive
Annual Permit Maintenance and Permit Modification Fee invoices if applicable).
Billing Name:
Contact Name:
Dou alss L. Karczewski
Address:
1081 East Water Street
City, State and Zip Code:
Charlottesville VA 22902
Phone Number:
Primary and CC Email:
Rev 11/2020 PAGE 2 16
CONSTRUCTION GENERAL PERMIT (VAR10) REGISTRATION STATEMENT 2019
Section V. Certification. A person representing the operator as identified in Section I. A. and meeting the requirements
of 9VAC25-880-70, Part III. K must physically sign this certification. A typed signature is not acceptable. Please note that
operator is defined in 9VAC25-870-10 as follows:
"Operator" means the owner or operator of any facility or activity subject to the Act and this chapter. In the context of stormwater
associated with a large or small construction activity, operator means any person associated with a construction project that meets
either of the following two criteria: N the person has direct operational control over construction plans and specifications, including
the ability to make modifications to those plans and specifications or (ii) the person has day-to-day operational control of those
activities at a project that are necessary to ensure compliance with a stormwater pollution prevention plan for the site or otherstate
permit or VSMP authority permit conditions (i.e., they are authorized to direct workers at a site to carry out activities required by the
stormwater pollution prevention plan or comply with other permit conditions). In the context of stormwater discharges from
Municipal Separate Storm Sewer Systems (MS4s), operator means the operator of the regulated MS4 system.
9VAC25-880-70, Part III. K. Signatory Requirements. Registration Statement. All Registration Statements shall be signed as follows:
a. For a corporation: by a responsible corporate officer. For the purpose of this chapter, a responsible corporate officer
means: (1) a president secretary, treasurer, or vice-president of the corporation in charge of a principal business function, or
any other person who performs similar policy -making or decision -making functions for the corporation; or (ii) the manager
of one or more manufacturing, production, or operating facilities, provided the manager is authorized to make management
decisions that govern the operation of the regulated facility including having the explicit or implicit duty of making major
capital investment recommendations, and initiating and directing other comprehensive measures to assure long-term
compliance with environmental laws and regulations; the manager can ensure that the necessary systems are established or
actions taken to gather complete and accurate information for state permit application requirements; and where authority
to sign documents has been assigned or delegated to the manager in accordance with corporate procedures;
b. For a partnership orsole proprietorship: by a general partner or the proprietor, respectively; or
c. For a municipality, state, federal, or other public agency: by either a principal executive officer or ranking elected official.
For purposes of this chapter, a principal executive officer of a public agency includes: (1) the chief executive officer of the
agency or (h) a senior executive officer having responsibility for the overall operations of a principal geographic unit of the
agency.
Certification: "I certify under penalty of law that I have read and understand this Registration Statement and that this
document and all attachments were prepared in accordance with a system designed to assure that qualified personnel
properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage
the system or those persons directly responsible for gathering the information, the information submitted is to the best
of my knowledge and belief true, accurate, and complete. I am aware that there are significant penalties for submitting
false information including the possibility of fine and imprisonment for
knowing violations."
Printed Name: G 1t i 7to�i+e r
Signature (signed in ink):
Date Signed:
Section VI. Submittal Instructions. Submit this form to the VSMP Authority. If the locality is the VSMP Authority, please
send your Registration Statement submittal directly to the locality; do NOT send this form to DEQ. A list of local VSMP
Authorities is available here: VSMP Authorities.
If DEQ is the VSMP Authority please send to: If the locality is the VSMP Authority, please send to:
Department of Environmental Quality
Office of Stormwater Management Suite 1400
PO Box 1105
Richmond VA 23218
constructiongpOdeg.vi rginia.eov
Albemarle County
Attn: Community Development
401 McIntire Rd., North Wing
Charlottesville, VA 22902
Rev 11/2020
PAGE 3 16
Section 2. Notice of general permit coverage
(This notice is to be posted near the main entrance according to 9VAC25-880-70, Part II, section
C.) (Provide a copy of the DEQ coverage letter when obtained)
Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County
Section 3. Nature of activity
(Provide a detailed narrative of the construction activities. Include or reference a construction schedule and
sequence. Include any phasing.)
Project Description:
This project proposes to build a single-family residence and barn on lot A9 located in Bundoran Farm. The
development will include a long private drive leading to the residence with plans of a future agricultural barn and
associated drive. The allotted home -site area consists of approximately 1.96 of the 23.6 acre parcel. The limits
ofdisturbed land will include approximately 1.96 acres in total for the development.
Sequence of Construction:
1. After obtaining all required permits, the contractor shall coordinate a pre -construction meeting, allowing 72 hours
for its coordination.
2. Install construction entrance off of Bundoran Drive.
2.1 Should the temporary construction entrance off of Bundoran Drive not be maintained properly or an
excessive amount of soil found tracked onto the private roadway, then a paved construction entrance, water tanker
truck with two pressure washers and a settling area may be required by the erosion and sediment control program
administrator.
3. Clearing and grubbing shall first be limited to that necessary to install silt fence, and other perimeter controls. All
perimeter controls must be made functional prior to any upslope land disturbance that takes place.
3.1 Silt fence shall be installed on the downhill side of the active trenching operations
4. Prior to additional clearing and grubbing, the contractor shall coordinate inspections, as required by the county of
Albemarle.
5. Clear and grub the remainder of project area.
5.1 The land disturbance shall be restricted to the limits of disturbance shown in the approved erosion control
plans.
5.2 These limits are confined to the property boundaries shown heron this plan.
6. Stockpile topsoil within an area on the property or a location approved by Albemarle County Community
Development. Install silt fence at the perimeter of stockpile(s) as necessary.
7. Denuded areas shall drain to an approved erosion control measure at all times during construction.
8. Permanent or temporary soil stabilization shall be applied to all denuded areas within seven days after final
grade is reached on any portion of the site. Temporary soil stabilization shall be applied within seven days to
denuded areas that may not be at final grade but will remain dormant for longer than 30 days. Permanent
stabilization shall be applied to areas that are to be left dormant for more than one year.
9. Lime, fertilize and apply temporary or permanent seeding to all denuded areas immediately after achieving final
grades.
10. All permanent slopes steeper than 3:1 shall receive stabilization with landscaping vegetation hardier than rass,
which will not require mowing.
11. After proposed construction is completed and the site is completely stabilized, permission is to be obtained from
the Erosion Control Inspector for the removal of the silt fencing and other remaining temporary erosion control
measures.
Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County
Section 4. Erosion and Sediment Control Plan.
(Provide a reduced, 11x17 copy of the latest Erosion and Sediment Control Plan. Do not reference only.)
Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County
Section 5. Stormwater Management Plan
(Provide a reduced 1 Ix 17 copy of the latest Stormwater management plan. Do not reference only.)
Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County
Section 6. Pollution Prevention Plan.
(reference County Code 17-404 and State Regulation 9VAC25-880-70 part II section AA)
A. Plan showing pollution activities and prevention practices
(Provide a reduced I W 7 copy of a site plan on which all of the following activity locations are clearly
marked. Keep this plan up-to-date with ongoing site changes and inspections.)
Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County
B. Sources of Pollutants. locations. and prevention practices
**spaces left blank for additional pollutants contractor may encounter during operations**
Pollutant, or Pollutant Location on site Prevention Practices,
Generating Activity Control Measures
Diesel Fuel
Leaks, staging area
Provide double walled tanks, a lined
containment area, drip pans, and
s ill revention cleanup materials.
Gasoline
Leaks, staging area
Provide double walled tanks, a lined
ontainment area, drip pans, and spill
revention cleanu materials.
Antifreeze/Coolant
Leaks/broken hoses equipment
Provide spill prevention cleanup
aterials and an onsite spill report
orm
Fertilizer
Newly seeded areas
pply fertilizers in accordance with
anufacturer's recommendations and
of during rainfall events.
Hydraulic Oils/Fluids
Leaks/broken hoses equipment
Provide spill prevention cleanup
aterials and an onsite spill report
orm
Plaster
Home construction
Follow manufacturer's instructions
and MSDS sheets.
Glue/Adhesives
Home construction
Follow manufacturer's instructions
and MSDS sheets.
Pesticides (insect/fungi/herb)
weed/pest control
Apply in accordance with
manufacture's recommendations and
of during rainfall events.
Asphalt
Roofing/driveway
over storm drain inlets, use oil
absorbent mats for spills for use in
roofing
C. Sources of Pollutants, continued. Common activities and minimum control and prevention
aactices
Pollutant, or Pollutant
Location on site
Prevention Practices,
Generating Activity
Control Measures
Follow Erosion and Sediment Control
Clearing, grading, excavating, and on-
Land disturbance area
Plan. Dispose of clearing debris at
stabilized areas
acceptable disposal sites. Seed and mulch,
or sod within 7 days of land clearing
Cover storm drain inlets and use drip
Paving operations
Roads and driveways
pans and absorbent/oil dry for all paving
machines to limit leaks and spills
Direct concrete wash water into a leak -
Concrete washout
Current location and detail shown
proof container or leak -proof settling
and cement waste
on plan
basin that is designed so that no overflows
can occur
Enclose or cover material storage areas.
Mix paint indoors in a containment area or
Structure construction, stucco,
Structures
in a flat unpaved area. Prevent the
painting, and cleaning
discharge of soaps, solvents, detergents
and wash water, paint, form release oils
and curing compounds.
Water shall be filtered, settled or similarly
Dewatenng operations
Dewatering sites shown on plan
treated prior to discharge as shown on
plan.
Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County
Material delivery and storage
Designated area shown on plan
Designated areas for material delivery
and storage. Placed near construction
entrances, away from waterways and
drainage paths
Material use during building process
Building areas
Follow manufacturer's instructions
. MSDS's attached.
waste collection area will not receive a
substantial amount of runoff from upland
Solid waste disposal
Current designated container areas
areas and does not drain directly to a
on plan
waterway. Containers have lids covered
before periods of rain, or are m a covered
area. Scheduled collection to prevent
Pollutant, or Pollutant
Location on site
Prevention Practices,
Generating Activity
Control Measures
overfilling. MATERIALS NOT TO BE
BURIED ON -SITE
Convenient and well -maintained
portable sanitary facilities will be
Sanitary waste
Current locations shown on plan
provided, and located away from
waterways or inlets. Such facilities shall
be regularly maintained.
Apply fertilizers in accordance with
Landscaping operations
Landscape areas shown on plan
manufacturer's recommendations and
not during rainfall events
To be treated in a sediment basin or
Wash Waters
Wash areas shown on plan
better control as specified on plan.
Minimize the discharge of pollutants
from equipment and vehicle washing
Vehicle and equipment washing
Designated areas and details shown on
Provide containment and filtering for all
plan
wash waters per the plan
Minlmizafion of exposure to precipitation and stormwater. Minimize the exposure of building materials, building products,
construction wastes, trash, landscape materials, fertilizers, pesticides, herbicides, detergents, sanitary waste, and other materials
present on the site to precipitation and to stormwater.
Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County
(Identify all non-stormwater discharges to occur on your site. Keep this plan up-to-date with ongoing site
changes and inspections. See CGP, 9VAC25-880-70 section E for examples of non-stormwater discharges.)
D. Non-stormwater discharges
Discharge
Pollutants or Pollutant
Constituents
Location on Site
Water for Dust treatment
Waterline flushing's/fire flow ana.
Foundation/roof drains
Landscape irrigation
Discharges from fire -fighting
activities
Routine external building wash
own that does not use
detergents
Uncontaminated air condition or
compressor condensate
Uncontaminated ground water or
spring water
Uncontaminated excavation
ewaterin
Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County
E. Persons responsible for pollution prevention practices
(Provide the names and contact information for all persons responsible for prevention practices as listed above.)
Bramante Homes- Christopher Brement
Backhoe Bob's- Darrin Duval RLD04785, expires 8/10/2022
F. Response and reporting practices
Minimize dischargesfrom spills and leaks. Minimize the discharge of pollutants from spills and leaks and implement chemical
spill and leak prevention and response procedures as follows.
Respond to all spills, leaks and discharges as follows,
Report all spills, leaks and discharges as follows,
(Provide detailed response and reporting practices according to 9VAC25-880-70, Part II, section A.4.e.)
Spill control Practices:
In addition to the good housekeeping and material management practices (discussed in next section), the following
practices will be followed for spill prevention and cleanup:
1. Manufacturers' recommended methods for spill cleanup will be clearly posted and site personnel will be made
aware of the procedures and the location of the information and cleanup supplies.
2. Materials and equipment necessary for spill cleanup will be kept in the material storage area onsite. Equipment
and materials may include but not be limited to brooms, dust pans, mops, rags, gloves, goggles, absorbent
material (e.g., kitty litter, sand, sawdust) and plastic and metal trash containers.
3. All spills will be cleaned up immediately after discovery.
4. In the event of a spill of a hazardous substance, the spill will be immediately contained and the spill area will be
kept well ventilated. Personnel will wear appropriate protective clothing to prevent injury form contact with a
hazardous substance during cleanup operation.
5. Spills of toxic or hazardous material will be reported to the appropriate State or local government agency, as
required by regulatory standards. Call the agencies listed below to report any spills of toxic or hazardous material:
Albemarle County Fire Department:
434-296-5833
Albemarle County Police Department:
434-977-9041
Albemarle County Health Department:
434-972-6200
VA Department of Conservation & Recreation:
1-804-786-2094
VDEQ Valley Regional Office: M-F, 8:30-4:30
540-574-7800
VA Department of Emergency Services:
1-800-468-8892
Local VSMP Authority: M-F, 8:00-5:00
434-296-5832
Spill Procedure
1) Check for hazards (flammable material, noxious fumes, cause of spill) - if flammable liquid, turn off engines
and nearby electrical equipment. If serious hazards are present, leave the area and call 911.
Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County
2) Make sure the spill area is safe to enter and that it does not pose an immediate threat to health or safety of
any person.
3) Stop the spill source.
4) Call co-workers and supervisor for assistance and to make them aware of the spill and potential dangers.
5) If possible, stop spill from entering drains (use absorbent or other material as necessary)
6) Stop spill from spreading (use absorbent or other materials necessary)
7) If spill material has entered a storm sewer or public waters; contact locality's storm sewer water department,
locality's VSMP inspector, local VDEQ Office and VA Department of emergency services.
8) Clean up spilled material and do not flush area with water.
9) Properly dispose of cleaning materials and used absorbent material according to manufacturer
specifications.
Maintenance and Insoection Procedures:
Inspections of the construction site shall be completed by persons designated by the contractor (to be written in closer to
construction). The SWPPP will be updated as new inspectors are hired and a Delegation of Authority completed and inserted
into SWPPP notebook.
Erosion and sediment control measures identified in the plan shall be observed to ensure that they are still operating correctly
The contractor shall inspect all erosion control measures at least once every 4 or 5 business days and after each significant
rainfall producing event. Any necessary repairs or cleanup to maintain the effectiveness of the erosion control devices shall
be made within seven (7) days.
Inspections shall be conducted (i) at least once every four (4) business days or (ii) at least once every five (5) business days
and no later than 24 hours following a measurable storm event. In the event that a measurable storm event occurs when there
are more than 24 hours between business days, the inspection shall be conducted on the next business day. These
inspections shall cover disturbed areas that have not been finally stabilized, areas used for storage of materials that are
exposed to precipitation, structural control measures, and locations where vehicles enter or exit the site.
Where areas have been finally or temporarily stabilized or runoff is unlikely due to winter conditions (e.g. site is covered with
snow, ice or frozen ground exists) such inspections shall be conducted at least once every month. If weather conditions (such
a above freezing temperatures or rain/snow events) make discharges likely, the operator shall immediately resume the regular
inspection frequency.
Reports summarizing each inspection shall be retained onsite as part of this Stormwater Pollution Prevention Plan
Each inspection report shall include the following items:
a) The date and time of the inspection and when applicable, the date and rainfall amount of the last measurable
storm event
b) Summarized findings of the inspection
c) The location(s) of prohibited discharges
d) The location(s) of controlled measures that require maintenance
e) The location(s) of control measures that failed to operate as designed or proved inadequate or inappropriate for a
particular location
t) The location(s) where any evidence identified under Park II G3a(7) exists
g) The location(s) where any additional control measure is needed that did not exist at the time of inspection
h) A list of corrective actions required (including nay changes to the SWPPP that are necessary) as a result of the
inspection or to maintain permit compliance
i) Documentation of any corrective actions required from a previous inspection that have not been implemented
j) The date and signature of the qualified personnel and the operator or its duly authorized representative in
accordance with Part III K of the general permit
Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County
G. Pollution Prevention Awareness
(Describe training and procedures to provide awareness and compliance for all measures in this
document; waste management, wash waters, prevention measures, etc.)
Employee Training:
Employee training with regard to material management practices is conducted at the site. Training includes discussions of
spill response, good housekeeping, and other material management practices. Employee training generally occurs with each
new employee once hired by the site contractor. Weekly tailgate training meetings are advised to ensure that as the site
evolves and changes employees are up to date on all PPP practices. A training log is advised to document these meetings
with all attendees listed.
Good Housekeeping:
The following good housekeeping practices will be followed onsite during the construction project
1. All materials stored onsite will be stored in a neat, orderly manner in their appropriate containers.
Materials which have the potential for contaminating runoff during storm events will be stored in
their appropriate watertight containers, stored under a canopy, tarpaulin, shrink wrapped or
otherwise precluded from direct exposure of precipitation.
2. Empty containers that may contain chemical residues shall be disposed of in accordance with
State and Local regulations.
3. Products, where possible, will be kept in their original containers with the original manufacture's
label.
4. Chemical or petroleum products will not be mixed with one another unless recommended by the
manufacturer.
5. Whenever possible, all of a product will be used up before disposing of the container.
6. Manufacturer's recommendations for proper use and disposal will be followed.
7. The site superintendent will inspect daily to ensure proper use and disposal of materials onsite.
Hazardous Products:
These practices are used to reduce the risk associated with hazardous materials. Hazardous waste to include oil filters,
petroleum products, paint, curing compounds and equipment maintenance fluids.
1. Products will be kept in original containers unless they are not re -sealable.
2. Products will be stored in structurally sound and sealed containers and segregated from other non -waste
materials.
3. Original specimen labels and materials safety data sheets will be kept on file; they contain important product
information.
4. If surplus product must be disposed of, manufacturers and/or local and State recommended methods for
proper disposal will be followed.
Product Specific Practices:
The following product specific practices will be followed onsite:
(a) Petroleum Products:
1. All onsite vehicles will be monitored for fluid leaks and will receive regular preventive
maintenance to reduce the chance of leakage.
2. It is recommended that, if practicable, all refueling, repair and changing of equipment and vehicle
fluids shall be conducted in a designated area, with the use of either spill buckets and/or fuel spill
mats to reduce the potential for contamination. This area will be designed in a manner to reduce
the potential for contamination of onsite resources. For refueling, repair and changing of
equipment and vehicle fluids outside of the designated areas, care should be taken to avoid
activities within +/- 50 feet of wetlands, streams, water bodies, tree preservation areas or any
other environmentally sensitive areas.
3. Petroleum products will be stored in tightly sealed containers which are clearly labeled.
4. An area will be designated for the collection and storage of all chemical and storage of all
chemical and petroleum -based products and containers for those products. The containers shall
Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County
be protected from rain events. These areas are identified on the SWPPP/PPP Reference
Drawing included with the "Final Construction Plans".
5. Any asphalt substances used onsite will be applied according to the manufacturer's
recommendations.
6. The project superintendent will regularly inspect the site to insure proper disposal methods of
used antifreeze, oils, filters and other hazardous materials are followed.
(b) Fertilizers:
Fertilizers used will be applied according to manufacturer's product standards. The contents of any partially
used bags of fertilizer will be transferred to a sealable plastic container to avoid spills.
(c) Paints, Curing Compounds, Soaps, Solvents, and Detergents:
All containers will be tightly sealed and stored when not required for use. Excess paint will be properly
disposed of according to manufacturers' instructions or State and local regulations. Discharges of soaps,
solvents and detergents are prohibited.
(d) Concrete Trucks and Wash Water from Construction Materials and Vehicles:
Concrete trucks will only wash out or discharge surplus concrete or drum wash water at approved locations in
accordance with State and local regulations. Wash water must be directed into a leak proof container or leak-
proof settling basin that is properly designed. The liquid and hardened concrete must then be handled and
disposed of properly and is not to be discharged. Washout areas are identified on the SWPPP/PPP
Reference Drawing included with the "Final Construction Plans". An EPA concrete washout factsheet is
provided in Appendix I. Water from vehicle wash stations (if needed) is to be directed to the nearest trap as
shown on the approved erosion and sediment control plan before discharged.
(e) Solid Waste:
All waste materials will be collected and disposed of into a metal trash dumpster in the staging area.
Dumpsters will have a secure watertight lid, be placed away from stormwater conveyances and drains, and
meet all local and state solid -waste management regulations. Only trash and construction debris from the site
will be deposited in the dumpsters. All personnel will be instructed, during tailgate training sessions, regarding
the correct procedure for disposal of trash and construction debris. Notices that state these practices will be
posted in the office trailer and the individual who manages day-to-day site operations will be responsible for
seeing that these practices are followed
(f) Sanitary Waste:
Portable lavatories are located on -site and are serviced on a regular basis by a contractor. They will be
located in up -land areas away from direct contact with surface waters. Any spills occurring during servicing
will be cleaned up immediately, including any contaminated soils, and disposed of according to all federal,
state, and local regulations.
(g) Minimization of Exposure to Precipitation and Storm Events
In the event that precipitation is predicted onsite, construction activity operator to ensure that all building
materials, building products, construction wastes, trash, landscape materials, fertilizers, pesticides,
detergents, sanitary waste and other materials present onsite is protected from the runoff by the sure of
covering tarps that securely fastened to eliminate blow off.
Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County
Section 7. Discharges to impaired waters, surface waters within an applicable TMDL
wasteload allocation, and exceptional waters.
(Provide detailed measures for any applicable TMDL)
Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County
Fact Sheets for
Impaired (Category 4 or S) Waters in 2020
James River Basin
Cause Group Code: H18R-01-BAC North Fork Hardware River
Cause Location: North Fork Hardware River from the headwaters downstream to its confluence with the Hardware River. (Start Mile:
11.35 End Mile: 0.00 Total Impaired Size: 11.35)
City / County: Albemarle Co.
Use(s): Recreation
Cause(s) / VA Category: Escherichia coil (E. coil) / 4A Fecal Coliform / 4A
This segment is impaired due to exceedances of the e-coli bacteria WQS at stations: 2-HNF000.10 (8 exceedances of 36
samples for a -soli) and 2-HNF005.03 (2 exceedances of 12 samples for e-coli). Initial Listing Date: 2004. This segment is
included in the EPA approved North Fork Hardware River bacteria TMDL. Federal TMDL ID # 34144.
Cycle TMDL
Cause First Dev. Water
Assessment Unit / Water Name / Location Desc. Category Cause Name Listed Priority Size
VAV-H18R_HNF01A00 / Hardware River North Fork / North Fork 4A Escherichia coil (E. coli) 2008 L 11.34
Hardware River form the headwaters downstream to its confluence
with the Hardware River.
North Fork Hardware River Estuary Reservoir River
Recreation (Sq. Miles) (Acres) (Miles)
Escherichia coil (E. coil) - Total Impaired Size by Water Type: 11.34
Cause
Assessment Unit / Water Name / Location Desc. Category Cause Name
VAV-H18R HNFO1A00 / Hardware River North Fork / North Fork 4A Fecal Coliform
Hardware River form the headwaters downstream to its confluence
with the Hardware River.
North Fork Hardware River
Recreation
Sources:
Agriculture
Fecal Coliform - Total Impaired Size by Water Type:
Non -Point Source Wildlife Other than
Waterfowl
Final 2020 Appendix 5 - 955
Cycle
TMDL
First
Dev. Water
Listed
Priority Size
2004
L 11.34
Estuary Reservoir River
(Sq. Miles) (Acres) (Miles)
11.34
Section 8. Qualified personnel
The following personnel are responsible for inspections;
(Provide the name, telephone number, and qualifications of the qualified personnel conducting inspections.)
Bramante Homes representative- Christopher Brement
506 Locust Ave.
Charlottesville, VA 22902
434-202-8500
Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County
Section 9. Signed Certification
(Provide certification according to 9VAC25-870-370)
CERTIFICATION
"I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in
accordance with a system designed to assure that qualified personnel properly gather and evaluate the information
submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for
gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and
complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine
and imprisonment for knowing violations."
Operator Name:
Company: `JQ�ti
Title: '+ r4-6
Signature:
Date: y 1 tj / l0L 1
Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County
Section 10. Delegation of authority.
(Provide the persons or positions with authority to sign .inspection reports or to modify the stormwater pollution
prevention plan. A formal, signed delegation of authority is needed.)
Delegation of Authority
I Ql .$ 6 s • k "r c V-C, ft. (name), hereby designate the person or specifically described position below to be a duly authorized
representative for the purpose of overseeing compliance with environmental requirements, including the Construction General Permit,
at the A -i gvnitd An Fne n construction site. The designee is authorized to sign any reports, stormwater
pollution prevention plans and all other documents required by the permit.
t t+� ff (name of person or position)
(company)
(address)
Gta. I o tFts v: jr-, l/Ei- 22°I o9. (city, state, zip)
t Lo L— Sy 0 (phone)
By signing this authorization, I confirm that I meet the requirements to make such a designation as set forth in the Construction
General Permit (CGP), and that the designee above meets the definition of a "duly authorized representative".
Operator Name: � g (� S C-
Company: N
Title:
Signature:
Date: s✓/�i ����
Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County
Section It. General permit copy
(Provide a copy of the construction general permit, 9VAC25-880)
Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County
COMMONWEALTH of VIRGINIA
DEPARTMENT OF ENVIRONMENTAL QUALITY
General Permit No.: VAR10
Effective Date: July 1, 2019
Expiration Date: June 30, 2024
GENERAL VPDES PERMIT FOR DISCHARGES OF
STORMWATER FROM CONSTRUCTION ACTIVITIES
AUTHORIZATION TO DISCHARGE UNDER THE VIRGINIA STORMWATER MANAGEMENT
PROGRAM AND THE VIRGINIA STORMWATER MANAGEMENT ACT
In compliance with the provisions of the Clean Water Act, as amended, and pursuant to the
Virginia Stormwater Management Act and regulations adopted pursuant thereto, operators of
construction activities are authorized to discharge to surface waters within the boundaries of the
Commonwealth of Virginia, except those specifically named in State Water Control Board
regulations that prohibit such discharges.
The authorized discharge shall be in accordance with the registration statement filed with the
Department of Environmental Quality, this cover page, Part I - Discharge Authorization and
Special Conditions, Part II - Stormwater Pollution Prevention Plan, and Part III - Conditions
Applicable to All VPDES Permits as set forth in this general permit.
Construction General Permit
Effective July 1, 2019
Page 2 of 26
10M.T 1
DISCHARGE AUTHORIZATION AND SPECIAL CONDITIONS
A. Coverage under this general permit.
During the period beginning with the date of coverage under this general permit and lasting
until the general permit's expiration date, the operator is authorized to discharge stormwater
from construction activities.
This general permit also authorizes stormwater discharges from support activities (e.g.,
concrete or asphalt batch plants, equipment staging yards, material storage areas, excavated
material disposal areas, borrow areas) located on -site or off -site provided that:
a. The support activity is directly related to the construction activity that is required to have
general permit coverage for discharges of stormwater from construction activities;
b. The support activity is not a commercial operation, nor does it serve multiple unrelated
construction activities by different operators;
c. The support activity does not operate beyond the completion of the last construction
activity it supports;
d. The support activity is identified in the registration statement at the time of general permit
coverage;
e. Appropriate control measures are identified in a stormwater pollution prevention plan and
implemented to address the discharges from the support activity areas; and
f. All applicable state, federal, and local approvals are obtained for the support activity.
B. Limitations on coverage.
1. Post -construction discharges. This general permit does not authorize stormwater discharges
that originate from the site after construction activities have been completed and the site,
including any support activity sites covered under the general permit registration, has
undergone final stabilization. Post -construction industrial stormwater discharges may need to
be covered by a separate VPDES permit.
Discharges mixed with nonstormwater. This general permit does not authorize discharges that
are mixed with sources of nonstormwater, other than those discharges that are identified in
Part I E (Authorized nonstormwater discharges) and are in compliance with this general
permit.
Discharges covered by another state permit. This general permit does not authorize
discharges of stormwater from construction activities that have been covered under an
individual permit or required to obtain coverage under an alternative general permit.
Page 3 of 26
4. Impaired waters and total maximum daily load (TMDL) limitation.
Nutrient and sediment impaired waters. Discharges of stormwater from construction
activities to surface waters identified as impaired in the 2016 § 305(b)/303(d) Water
Quality Assessment Integrated Report or for which a TMDL wasteload allocation has
been established and approved prior to the term of this general permit for (i) sediment
or a sediment -related parameter (i.e., total suspended solids or turbidity) or (ii)
nutrients (i.e., nitrogen or phosphorus) are not eligible for coverage under this general
permit unless the operator develops, implements, and maintains a stormwater
pollution prevention plan (SWPPP) in accordance with Part II B 5 of this permit that
minimizes the pollutants of concern and, when applicable, is consistent with the
assumptions and requirements of the approved TMDL wasteload allocations and
implements an inspection frequency consistent with Part II G 2 a.
Polychlorinated biphenyl (PCB) impaired waters. Discharges of stormwater from
construction activities that include the demolition of any structure with at least 10,000
square feet of floor space built or renovated before January 1, 1980, to surface waters
identified as impaired in the 2016 § 305(b)/303(d) Water Quality Assessment
Integrated Report or for which a TMDL wasteload allocation has been established and
approved prior to the term of this general permit for PCB are not eligible for coverage
under this general permit unless the operator develops, implements, and maintains a
SWPPP in accordance with Part II B 6 of this permit that minimizes the pollutants of
concern and, when applicable, is consistent with the assumptions and requirements
of the approved TMDL wasteload allocations, and implements an inspection frequency
consistent with Part II G 2 a.
Exceptional waters limitation. Discharges of stormwater from construction activities not
previously covered under the general permit effective on July 1, 2014, to exceptional waters
identified in 9VAC25-260-30 A 3 c are not eligible for coverage under this general permit
unless the operator develops, implements, and maintains a SWPPP in accordance with Part
II B 7 of this permit and implements an inspection frequency consistent with Part II G 2 a.
6. There shall be no discharge of floating solids or visible foam in other than trace amounts
C. Commingled discharges. Discharges authorized by this general permit may be commingled
with other sources of stormwater that are not required to be covered under a state permit, so long
as the commingled discharge is in compliance with this general permit. Discharges authorized by
a separate state or VPDES permit may be commingled with discharges authorized by this general
permit so long as all such discharges comply with all applicable state and VPDES permit
requirements.
D. Prohibition of nonstormwater discharges. Except as provided in Parts I A 2, 1 C, and I E, all
discharges covered by this general permit shall be composed entirely of stormwater associated
with construction activities. All other discharges including the following are prohibited:
1. Wastewater from washout of concrete;
2. Wastewater from the washout and cleanout of stucco, paint, form release oils, curing
compounds, and other construction materials;
Page 4 of 26
3. Fuels, oils, or other pollutants used in vehicle and equipment operation and maintenance;
4. Oils, toxic substances, or hazardous substances from spills or other releases; and
5. Soaps, solvents, or detergents used in equipment and vehicle washing.
E. Authorized nonstormwater discharges. The following nonstormwater discharges from
construction activities are authorized by this general permit when discharged in compliance with
this general permit:
1. Discharges from firefighting activities;
2. Fire hydrant flushings;
3. Waters used to wash vehicles or equipment where soaps, solvents, or detergents have not
been used and the wash water has been filtered, settled, or similarly treated prior to discharge;
4. Water used to control dust that has been filtered, settled, or similarly treated prior to discharge;
5. Potable water sources, including uncontaminated waterline flushings, managed in a manner
to avoid an instream impact;
6. Routine external building wash down where soaps, solvents or detergents have not been used
and the wash water has been filtered, settled, or similarly treated prior to discharge;
7. Pavement wash waters where spills or leaks of toxic or hazardous materials have not occurred
(or where all spilled or leaked material has been removed prior to washing); where soaps,
solvents, or detergents have not been used; and where the wash water has been filtered,
settled, or similarly treated prior to discharge;
8. Uncontaminated air conditioning or compressor condensate;
9. Uncontaminated ground water or spring water;
10. Foundation or footing drains where flows are not contaminated with process materials such
as solvents;
11. Uncontaminated excavation dewatering, including dewatering of trenches and excavations
that have been filtered, settled, or similarly treated prior to discharge; and
12. Landscape irrigation.
F. Termination of general permit coverage.
1. The operator of the construction activity shall submit a notice of termination in accordance
with 9VAC25-880-60, unless a registration statement was not required to be submitted in
accordance with 9VAC25-880-50 A 1 c or A 2 b for single-family detached residential
structures, to the VSMP authority after one or more of the following conditions have been met:
Page 5 of 26
a. Necessary permanent control measures included in the SWPPP for the site are in place
and functioning effectively and final stabilization has been achieved on all portions of the
site for which the operator has operational control. When applicable, long term
responsibility and maintenance requirements for permanent control measures shall be
recorded in the local land records prior to the submission of a complete and accurate
notice of termination and the construction record drawing prepared;
b. Another operator has assumed control over all areas of the site that have not been finally
stabilized and obtained coverage for the ongoing discharge;
c. Coverage under an alternative VPDES or state permit has been obtained; or
d. For individual lots in residential construction only, final stabilization as defined in 9VAC25-
880-1 has been completed, including providing written notification to the homeowner and
incorporating a copy of the notification and signed certification statement into the SWPPP,
and the residence has been transferred to the homeowner.
The notice of termination shall be submitted no later than 30 days after one of the above
conditions in subdivision 1 of this subsection is met.
3. Termination of authorization to discharge for the conditions set forth in subdivision 1 a of this
subsection shall be effective upon notification from the department that the provisions of
subdivision 1 a of this subsection have been met or 60 days after submittal of a complete and
accurate notice of termination in accordance with 9VAC25-880-60 C, whichever occurs first.
4. Authorization to discharge terminates at midnight on the date that the notice of termination is
submitted for the conditions set forth in subdivisions 1 b through 1 d of this subsection unless
otherwise notified by the VSMP authority or department.
5. The notice of termination shall be signed in accordance with Part III K of this general permit.
G. Water quality protection.
1. The operator shall select, install, implement, and maintain control measures as identified in
the SWPPP at the construction site that minimize pollutants in the discharge as necessary to
ensure that the operator's discharge does not cause or contribute to an excursion above any
applicable water quality standard.
If it is determined by the department that the operator's discharges are causing, have
reasonable potential to cause, or are contributing to an excursion above any applicable water
quality standard, the department, in consultation with the VSMP authority, may take
appropriate enforcement action and require the operator to:
a. Modify or implement additional control measures in accordance with Part II C to
adequately address the identified water quality concerns;
b. Submit valid and verifiable data and information that are representative of ambient
conditions and indicate that the receiving water is attaining water quality standards; or
Page 6 of 26
c. Submit an individual permit application in accordance with 9VAC25-870-410 B 3.
All written responses required under this chapter shall include a signed certification
consistent with Part III K.
STORMWATER POLLUTION PREVENTION PLAN
A. Stormwater pollution prevent plan.
A stormwater pollution prevention plan (SWPPP) shall be developed prior to the submission
of a registration statement and implemented for the construction activity, including any support
activity, covered by this general permit. SWPPPs shall be prepared in accordance with good
engineering practices. Construction activities that are part of a larger common plan of
development or sale and disturb less than one acre may utilize a SWPPP template provided
by the department and need not provide a separate stormwater management plan if one has
been prepared and implemented for the larger common plan of development or sale.
The SWPPP requirements of this general permit may be fulfilled by incorporating by reference
other plans such as a spill prevention control and countermeasure (SPCC) plan developed for
the site under § 311 of the federal Clean Water Act or best management practices (BMP)
programs otherwise required for the facility provided that the incorporated plan meets or
exceeds the SWPPP requirements of Part II B. All plans incorporated by reference into the
SWPPP become enforceable under this general permit. If a plan incorporated by reference
does not contain all of the required elements of the SWPPP, the operator shall develop the
missing elements and include them in the SWPPP.
3. Any operator that was authorized to discharge under the general permit effective July 1, 2014,
and that intends to continue coverage under this general permit, shall update its stormwater
pollution prevention plan to comply with the requirements of this general permit no later than
60 days after the date of coverage under this general permit.
B. Contents. The SWPPP shall include the following items:
1. General information.
a. A signed copy of the registration statement, if required, for coverage under the general
VPDES permit for discharges of stormwater from construction activities;
b. Upon receipt, a copy of the notice of coverage under the general VPDES permit for
discharges of stormwater from construction activities (i.e., notice of coverage letter);
c. Upon receipt, a copy of the general VPDES permit for discharges of stormwater from
construction activities;
d. A narrative description of the nature of the construction activity, including the function of
the project (e.g., low density residential, shopping mall, highway, etc.);
e. A legible site plan identifying:
Page 7 of 26
(1) Directions of stormwater flow and approximate slopes anticipated after major grading
activities;
(2) Limits of land disturbance including steep slopes and natural buffers around surface
waters that will not be disturbed;
(3) Locations of major structural and nonstructural control measures, including sediment
basins and traps, perimeter dikes, sediment barriers, and other measures intended to
filter, settle, or similarly treat sediment, that will be installed between disturbed areas
and the undisturbed vegetated areas in order to increase sediment removal and
maximize stormwater infiltration;
(4) Locations of surface waters;
(5) Locations where concentrated stormwater is discharged;
(6) Locations of any support activities, including (i) areas where equipment and vehicle
washing, wheel wash water, and other wash water is to occur; (ii) storage areas for
chemicals such as acids, fuels, fertilizers, and other lawn care chemicals; (iii) concrete
wash out areas; (iv) vehicle fueling and maintenance areas; (v) sanitary waste
facilities, including those temporarily placed on the construction site; and (vi)
construction waste storage; and
(7) When applicable, the location of the on -site rain gauge or the methodology established
in consultation with the VSMP authority used to identify measurable storm events for
inspection as allowed by Part II G 2 a (1) (ii) or Part II G 2 b (2).
Erosion and sediment control plan.
a. An erosion and sediment control plan designed and approved in accordance with the
Virginia Erosion and Sediment Control Regulations (9VAC25-840), an "agreement in lieu
of a plan" as defined in 9VAC25-840-10 from the VESCP authority, or an erosion and
sediment control plan prepared in accordance with annual standards and specifications
approved by the department.
b. All erosion and sediment control plans shall include a statement describing the
maintenance responsibilities required for the erosion and sediment controls used.
c. An approved erosion and sediment control plan, "agreement in lieu of a plan," or erosion
and sediment control plan prepared in accordance with department -approved annual
standards and specifications, implemented to:
(1) Control the volume and velocity of stormwater runoff within the site to minimize soil
erosion;
(2) Control stormwater discharges, including peak flow rates and total stormwater volume,
to minimize erosion at outlets and to minimize downstream channel and stream bank
erosion;
Page 8 of 26
(3) Minimize the amount of soil exposed during the construction activity;
(4) Minimize the disturbance of steep slopes;
(5) Minimize sediment discharges from the site in a manner that addresses (i) the amount,
frequency, intensity, and duration of precipitation; (ii) the nature of resulting stormwater
runoff; and (iii) soil characteristics, including the range of soil particle sizes present on
the site;
(6) Provide and maintain natural buffers around surface waters, direct stormwater to
vegetated areas to increase sediment removal, and maximize stormwater infiltration,
unless infeasible;
(7) Minimize soil compaction and, unless infeasible, preserve topsoil;
(8) Ensure initiation of stabilization activities, as defined in 9VAC25-880-1, of disturbed
areas immediately whenever any clearing, grading, excavating, or other land -
disturbing activities have permanently ceased on any portion of the site, or temporarily
ceased on any portion of the site and will not resume for a period exceeding 14 days;
and
(9) Utilize outlet structures that withdraw stormwater from the surface (i.e., above the
permanent pool or wet storage water surface elevation), unless infeasible, when
discharging from sediment basins or sediment traps.
3. Stormwater management plan.
a. Except for those projects identified in Part II B 3 b, a stormwater management plan
approved by the VSMP authority as authorized under the Virginia Stormwater
Management Program (VSMP) Regulation (9VAC25-870), or an "agreement in lieu of a
stormwater management plan" as defined in 9VAC25-870-10 from the VSMP authority, or
a stormwater management plan prepared in accordance with annual standards and
specifications approved by the department.
b. For any operator meeting the conditions of 9VAC25-870-47 B of the VSMP regulation, an
approved stormwater management plan is not required. In lieu of an approved stormwater
management plan, the SWPPP shall include a description of, and all necessary
calculations supporting, all post -construction stormwater management measures that will
be installed prior to the completion of the construction process to control pollutants in
stormwater discharges after construction operations have been completed. Structural
measures should be placed on upland soils to the degree possible. Such measures must
be designed and installed in accordance with applicable VESCP authority, VSMP
authority, state, and federal requirements, and any necessary permits must be obtained.
Pollution prevention plan. A pollution prevention plan that addresses potential pollutant -
generating activities that may reasonably be expected to affect the quality of stormwater
discharges from the construction activity, including any support activity. The pollution
prevention plan shall:
a. Identify the potential pollutant -generating activities and the pollutant that is expected to be
exposed to stormwater;
Page 9 of 26
b. Describe the location where the potential pollutant -generating activities will occur, or if
identified on the site plan, reference the site plan;
c. Identify all nonstormwater discharges, as authorized in Part I E of this general permit, that
are or will be commingled with stormwater discharges from the construction activity,
including any applicable support activity;
d. Identify the person responsible for implementing the pollution prevention practice or
practices for each pollutant -generating activity (if other than the person listed as the
qualified personnel);
e. Describe the pollution prevention practices and procedures that will be implemented to:
(1) Prevent and respond to leaks, spills, and other releases including (i) procedures for
expeditiously stopping, containing, and cleaning up spills, leaks, and other releases;
and (ii) procedures for reporting leaks, spills, and other releases in accordance with
Part III G;
(2) Prevent the discharge of spilled and leaked fuels and chemicals from vehicle fueling
and maintenance activities (e.g., providing secondary containment such as spill
berms, decks, spill containment pallets, providing cover where appropriate, and having
spill kits readily available);
(3) Prevent the discharge of soaps, solvents, detergents, and wash water from
construction materials, including the clean-up of stucco, paint, form release oils, and
curing compounds (e.g., providing (i) cover (e.g., plastic sheeting or temporary roofs)
to prevent contact with stormwater; (ii) collection and proper disposal in a manner to
prevent contact with stormwater; and (iii) a similarly effective means designed to
prevent discharge of these pollutants);
(4) Minimize the discharge of pollutants from vehicle and equipment washing, wheel wash
water, and other types of washing (e.g., locating activities away from surface waters
and stormwater inlets or conveyance and directing wash waters to sediment basins or
traps, using filtration devices such as filter bags or sand filters, or using similarly
effective controls);
(5) Direct concrete wash water into a leak -proof container or leak -proof settling basin. The
container or basin shall be designed so that no overflows can occur due to inadequate
sizing or precipitation. Hardened concrete wastes shall be removed and disposed of
in a manner consistent with the handling of other construction wastes. Liquid concrete
wastes shall be removed and disposed of in a manner consistent with the handling of
other construction wash waters and shall not be discharged to surface waters;
(6) Minimize the discharge of pollutants from storage, handling, and disposal of
construction products, materials, and wastes including (i) building products such as
asphalt sealants, copper flashing, roofing materials, adhesives, and concrete
admixtures; (ii) pesticides, herbicides, insecticides, fertilizers, and landscape
Page 10 of 26
materials; and (iii) construction and domestic wastes such as packaging materials,
scrap construction materials, masonry products, timber, pipe and electrical cuttings,
plastics, Styrofoam, concrete, and other trash or building materials;
(7) Prevent the discharge of fuels, oils, and other petroleum products, hazardous or toxic
wastes, waste concrete, and sanitary wastes;
(8) Address any other discharge from the potential pollutant -generating activities not
addressed above;
(9) Minimize the exposure of waste materials to precipitation by closing or covering waste
containers during precipitation events and at the end of the business day, or
implementing other similarly effective practices. Minimization of exposure is not
required in cases where the exposure to precipitation will not result in a discharge of
pollutants; and
f. Describe procedures for providing pollution prevention awareness of all applicable wastes,
including any wash water, disposal practices, and applicable disposal locations of such
wastes, to personnel in order to comply with the conditions of this general permit. The
operator shall implement the procedures described in the SWPPP.
SWPPP requirements for discharges to nutrient and sediment impaired waters. For
discharges to surface waters (i) identified as impaired in the 2016 § 305(b)/303(d) Water
Quality Assessment Integrated Report or (ii) with an applicable TMDL wasteload allocation
established and approved prior to the term of this general permit for sediment for a sediment -
related parameter (i.e., total suspended solids or turbidity) or nutrients (i.e., nitrogen or
phosphorus), the operator shall:
a. Identify the impaired waters, approved TMDLs, and pollutants of concern in the SWPPP;
and
b. Provide clear direction in the SWPPP that:
(1) Permanent or temporary soil stabilization shall be applied to denuded areas within
seven days after final grade is reached on any portion of the site;
(2) Nutrients shall be applied in accordance with manufacturer's recommendations or an
approved nutrient management plan and shall not be applied during rainfall events;
and
(3) A modified inspection schedule shall be implemented in accordance with Part II G 2 a.
SWPPP requirements for discharges to polychlorinated biphenyl (PCB) impaired waters. For
discharges from construction activities that include the demolition of any structure with at least
10,000 square feet of floor space built or renovated before January 1, 1980, to surface waters
(i) identified as impaired in the 2016 § 305(b)/303(d) Water Quality Assessment Integrated
Report or (ii) with an applicable TMDL wasteload allocation established and approved prior to
the term of this general permit for PCB, the operator shall:
Page 11 of 26
a. Identify the impaired waters, approved TMDLs, and pollutant of concern in the SWPPP;
b. Implement the approved erosion and sediment control plan in accordance with Part II B 2;
c. Dispose of waste materials in compliance with applicable state, federal, and local
requirements; and
d. Implement a modified inspection schedule in accordance with Part II G 2 a.
7. SWPPP requirements for discharges to exceptional waters. For discharges to surface waters
identified in 9VAC25-260-30 A 3 c as an exceptional water, the operator shall:
a. Identify the exceptional surface waters in the SWPPP; and
b. Provide clear direction in the SWPPP that:
(1) Permanent or temporary soil stabilization shall be applied to denuded areas within
seven days after final grade is reached on any portion of the site;
(2) Nutrients shall be applied in accordance with manufacturer's recommendations or an
approved nutrient management plan and shall not be applied during rainfall events;
and
(3) A modified inspection schedule shall be implemented in accordance with Part II G 2 a.
8. Identification of qualified personnel. The name, phone number, and qualifications of the
qualified personnel conducting inspections required by this general permit.
9. Delegation of authority. The individuals or positions with delegated authority, in accordance
with Part III K, to sign inspection reports or modify the SWPPP.
10. SWPPP signature. The SWPPP shall be signed and dated in accordance with Part III K.
C. SWPPP amendments, modification, and updates.
1. The operator shall amend the SWPPP whenever there is a change in the design, construction,
operation, or maintenance that has a significant effect on the discharge of pollutants to surface
waters and that has not been previously addressed in the SWPPP.
The SWPPP shall be amended if, during inspections or investigations by the operator's
qualified personnel, or by local, state, or federal officials, it is determined that the existing
control measures are ineffective in minimizing pollutants in discharges from the construction
activity. Revisions to the SWPPP shall include additional or modified control measures
designed and implemented to correct problems identified. If approval by the VESCP authority,
VSMP authority, or department is necessary for the control measure, revisions to the SWPPP
shall be completed no later than seven calendar days following approval. Implementation of
these additional or modified control measures shall be accomplished as described in Part II
H.
Page 12 of 26
3. The SWPPP shall clearly identify the contractors that will implement and maintain each control
measure identified in the SWPPP. The SWPPP shall be amended to identify any new
contractor that will implement and maintain a control measure.
4. The operator shall update the SWPPP as soon as possible but no later than seven days
following any modification to its implementation. All modifications or updates to the SWPPP
shall be noted and shall include the following items:
a. A record of dates when:
(1) Major grading activities occur;
(2) Construction activities temporarily or permanently cease on a portion of the site; and
(3) Stabilization measures are initiated;
b. Documentation of replaced or modified controls where periodic inspections or other
information have indicated that the controls have been used inappropriately or incorrectly
and were modified;
c. Areas that have reached final stabilization and where no further SWPPP or inspection
requirements apply;
d. All properties that are no longer under the legal control of the operator and the dates on
which the operator no longer had legal control over each property;
e. The date of any prohibited discharges, the discharge volume released, and what actions
were taken to minimize the impact of the release;
f. Measures taken to prevent the reoccurrence of any prohibited discharge; and
g. Measures taken to address any evidence identified as a result of an inspection required
under Part II G.
5. Amendments, modifications, or updates to the SWPPP shall be signed in accordance with
Part III K.
D. Public notification. Upon commencement of land disturbance, the operator shall post
conspicuously a copy of the notice of coverage letter near the main entrance of the construction
activity. For linear projects, the operator shall post the notice of coverage letter at a publicly
accessible location near an active part of the construction project (e.g., where a pipeline crosses
a public road). The operator shall maintain the posted information until termination of general
permit coverage as specified in Part I F.
E. SWPPP availability.
1. Operators with day-to-day operational control over SWPPP implementation shall have a copy
of the SWPPP available at a central location on -site for use by those identified as having
responsibilities under the SWPPP whenever they are on the construction site.
Page 13 of 26
The operator shall make the SWPPP and all amendments, modifications, and updates
available upon request to the department, the VSMP authority, the EPA, the VESCP authority,
local government officials, or the operator of a municipal separate storm sewer system
receiving discharges from the construction activity. If an on -site location is unavailable to store
the SWPPP when no personnel are present, notice of the SWPPP's location shall be posted
near the main entrance of the construction site.
The operator shall make the SWPPP available for public review in an electronic format or in
hard copy. Information for public access to the SWPPP shall be posted and maintained in
accordance with Part II D. If not provided electronically, public access to the SWPPP may be
arranged upon request at a time and at a publicly accessible location convenient to the
operator or his designee but shall be no less than once per month and shall be during normal
business hours. Information not required to be contained within the SWPPP by this general
permit is not required to be released.
F. SWPPP implementation. The operator shall implement the SWPPP and subsequent
amendments, modifications, and updates from commencement of land disturbance until
termination of general permit coverage as specified in Part I F.
All control measures shall be properly maintained in effective operating condition in
accordance with good engineering practices and, where applicable, manufacturer
specifications. If a site inspection required by Part II G identifies a control measure that is not
operating effectively, corrective actions shall be completed as soon as practicable, but no later
than seven days after discovery or a longer period as established by the VSMP authority, to
maintain the continued effectiveness of the control measures.
If site inspections required by Part II G identify an existing control measure that needs to be
modified or if an additional or alternative control measure is necessary for any reason,
implementation shall be completed prior to the next anticipated measurable storm event. If
implementation prior to the next anticipated measurable storm event is impracticable, then
additional or alternative control measures shall be implemented as soon as practicable, but
no later than seven days after discovery or a longer period as established by the VSMP
authority.
G. SWPPP Inspections.
1. Personnel responsible for on -site and off -site inspections. Inspections required by this general
permit shall be conducted by the qualified personnel identified by the operator in the SWPPP.
The operator is responsible for ensuring that the qualified personnel conduct the inspection.
2. Inspection schedule.
a. For construction activities that discharge to a surface water identified in Part 11 B 5 and B
6 as impaired or having an approved TMDL or Part I B 7 as exceptional, the following
inspection schedule requirements apply:
(1) Inspections shall be conducted at a frequency of (i) at least once every four business
days or (ii) at least once every five business days and no later than 24 hours following
a measurable storm event. In the event that a measurable storm event occurs when
Page 14 of 26
there are more than 24 hours between business days, the inspection shall be
conducted on the next business day; and
(2) Representative inspections as authorized in Part II G 2 d shall not be allowed.
b. Except as specified in Part II G 2 a, inspections shall be conducted at a frequency of:
(1) At least once every five business days; or
(2) At least once every 10 business days and no later than 24 hours following a
measurable storm event. In the event that a measurable storm event occurs when
there are more than 24 hours between business days, the inspection shall be
conducted on the next business day.
c. Where areas have been temporarily stabilized or land -disturbing activities will be
suspended due to continuous frozen ground conditions and stormwater discharges are
unlikely, the inspection frequency described in Part II G 2 a and 2 b may be reduced to
once per month. If weather conditions (such as above freezing temperatures or rain or
snow events) make discharges likely, the operator shall immediately resume the regular
inspection frequency.
d. Except as prohibited in Part II G 2 a (2), representative inspections may be utilized for
utility line installation, pipeline construction, or other similar linear construction activities
provided that:
(1) Temporary or permanent soil stabilization has been installed and vehicle access may
compromise the temporary or permanent soil stabilization and potentially cause
additional land disturbance increasing the potential for erosion;
(2) Inspections occur on the same frequency as other construction activities;
(3) Control measures are inspected along the construction site 0.25 miles above and
below each access point (i.e., where a roadway, undisturbed right-of-way, or other
similar feature intersects the construction activity and access does not compromise
temporary or permanent soil stabilization); and
(4) Inspection locations are provided in the inspection report required by Part II G.
e. If adverse weather causes the safety of the inspection personnel to be in jeopardy, the
inspection may be delayed until the next business day on which it is safe to perform the
inspection. Any time inspections are delayed due to adverse weather conditions, evidence
of the adverse weather conditions shall be included in the SWPPP with the dates of
occurrence.
3. Inspection requirements.
a. As part of the inspection, the qualified personnel shall:
(1) Record the date and time of the inspection and, when applicable, the date and rainfall
amount of the last measurable storm event;
Page 15 of 26
(2) Record the information and a description of any discharges occurring at the time of
the inspection or evidence of discharges occurring prior to the inspection;
(3) Record any land -disturbing activities that have occurred outside of the approved
erosion and sediment control plan;
(4) Inspect the following for installation in accordance with the approved erosion and
sediment control plan, identification of any maintenance needs, and evaluation of
effectiveness in minimizing sediment discharge, including whether the control has
been inappropriately or incorrectly used:
(a) All perimeter erosion and sediment controls, such as silt fence;
(b) Soil stockpiles, when applicable, and borrow areas for stabilization or sediment
trapping measures;
(c) Completed earthen structures, such as dams, dikes, ditches, and diversions for
stabilization and effective impoundment or flow control;
(d) Cut and fill slopes;
(e) Sediment basins and traps, sediment barriers, and other measures installed to
control sediment discharge from stormwater;
(f) Temporary or permanent channels, flumes, or other slope drain structures
installed to convey concentrated runoff down cut and fill slopes;
(g) Storm inlets that have been made operational to ensure that sediment laden
stormwater does not enter without first being filtered or similarly treated; and
(h) Construction vehicle access routes that intersect or access paved or public roads
for minimizing sediment tracking;
(5) Inspect areas that have reached final grade or that will remain dormant for more than
14 days to ensure:
(a) Initiation of stabilization activities have occurred immediately, as defined in
9VAC25-880-1; and
(b) Stabilization activities have been completed within seven days of reaching grade
or stopping work;
(6) Inspect for evidence that the approved erosion and sediment control plan, "agreement
in lieu of a plan," or erosion and sediment control plan prepared in accordance with
department -approved annual standards and specifications has not been properly
implemented. This includes:
Page 16 of 26
(a) Concentrated flows of stormwater in conveyances such as rills, rivulets, or
channels that have not been filtered, settled, or similarly treated prior to discharge,
or evidence thereof;
(b) Sediment laden or turbid flows of stormwater that have not been filtered or settled
to remove sediments prior to discharge;
(c) Sediment deposition in areas that drain to unprotected stormwater inlets or catch
basins that discharge to surface waters. Inlets and catch basins with failing
sediment controls due to improper installation, lack of maintenance, or inadequate
design are considered unprotected;
(d) Sediment deposition on any property (including public and private streets) outside
of the construction activity covered by this general permit;
(e) Required stabilization has not been initiated or completed or is not effective on
portions of the site;
(f) Sediment basins without adequate wet or dry storage volume or sediment basins
that allow the discharge of stormwater from below the surface of the wet storage
portion of the basin;
(g) Sediment traps without adequate wet or dry storage or sediment traps that allow
the discharge of stormwater from below the surface of the wet storage portion of
the trap; and
(h) Land disturbance or sediment deposition outside of the approved area to be
disturbed;
(7) Inspect pollutant generating activities identified in the pollution prevention plan for the
proper implementation, maintenance, and effectiveness of the procedures and
practices;
(8) Identify any pollutant generating activities not identified in the pollution prevention plan;
and
(9) Identify and document the presence of any evidence of the discharge of pollutants
prohibited by this general permit.
4. Inspection report. Each inspection report shall include the following items:
a. The date and time of the inspection and, when applicable, the date and rainfall amount of
the last measurable storm event;
b. Summarized findings of the inspection;
c. The locations of prohibited discharges;
d. The locations of control measures that require maintenance;
Page 17 of 26
e. The locations of control measures that failed to operate as designed or proved inadequate
or inappropriate for a particular location;
f. The locations where any evidence identified under Part II G 3 a (6) exists;
g. The locations where any additional control measure is needed;
h. A list of corrective actions required (including any changes to the SWPPP that are
necessary) as a result of the inspection or to maintain permit compliance;
i. Documentation of any corrective actions required from a previous inspection that have not
been implemented; and
The date and signature of the qualified personnel and the operator or its duly authorized
representative.
5. The inspection report shall be included into the SWPPP no later than four business days after
the inspection is complete.
The inspection report and any actions taken in accordance with Part II shall be retained by
the operator as part of the SWPPP for at least three years from the date that general permit
coverage expires or is terminated. The inspection report shall identify any incidents of
noncompliance. Where an inspection report does not identify any incidents of noncompliance,
the report shall contain a certification that the construction activity is in compliance with the
SWPPP and this general permit. The report shall be signed in accordance with Part III K of
this general permit.
H. Corrective actions.
The operator shall implement the corrective actions identified as a result of an inspection as
soon as practicable but no later than seven days after discovery or a longer period as
approved by the VSMP authority. If approval of a corrective action by a regulatory authority
(e.g., VSMP authority, VESCP authority, or the department) is necessary, additional control
measures shall be implemented to minimize pollutants in stormwater discharges until such
approvals can be obtained.
The operator may be required to remove accumulated sediment deposits located outside of
the construction activity covered by this general permit as soon as practicable in order to
minimize environmental impacts. The operator shall notify the VSMP authority and the
department as well as obtain all applicable federal, state, and local authorizations,
approvals, and permits prior to the removal of sediments accumulated in surface waters
including wetlands.
Page 18 of 26
PART III
CONDITIONS APPLICABLE TO ALL VPDES PERMITS
NOTE: Discharge monitoring is not required for this general permit. If the operator chooses to
monitor stormwater discharges or control measures, the operator shall comply with the
requirements of subsections A, B, and C, as appropriate.
A. Monitoring.
1. Samples and measurements taken for the purpose of monitoring shall be representative of
the monitoring activity.
Monitoring shall be conducted according to procedures approved under 40 CFR Part 136 or
alternative methods approved by the U.S. Environmental Protection Agency, unless other
procedures have been specified in this general permit. Analyses performed according to test
procedures approved under 40 CFR Part 136 shall be performed by an environmental
laboratory certified under regulations adopted by the Department of General Services
(1 VAC30-45 or 1 VAC30-46).
3. The operator shall periodically calibrate and perform maintenance procedures on all
monitoring and analytical instrumentation at intervals that will ensure accuracy of
measurements.
B. Records.
1. Monitoring records and reports shall include
a. The date, exact place, and time of sampling or measurements;
b. The individuals who performed the sampling or measurements;
c. The dates and times analyses were performed;
d. The individuals who performed the analyses;
e. The analytical techniques or methods used; and
f. The results of such analyses.
2. The operator shall retain records of all monitoring information, including all calibration and
maintenance records and all original strip chart recordings for continuous monitoring
instrumentation, copies of all reports required by this general permit, and records of all data
used to complete the registration statement for this general permit, for a period of at least
three years from the date of the sample, measurement, report or request for coverage. This
period of retention shall be extended automatically during the course of any unresolved
litigation regarding the regulated activity or regarding control standards applicable to the
operator, or as requested by the board.
C. Reporting monitoring results.
Page 19 of 26
1. The operator shall update the SWPPP to include the results of the monitoring as may be
performed in accordance with this general permit, unless another reporting schedule is
specified elsewhere in this general permit.
2. Monitoring results shall be reported on a discharge monitoring report (DMR); on forms
provided, approved or specified by the department; or in any format provided that the date,
location, parameter, method, and result of the monitoring activity are included.
If the operator monitors any pollutant specifically addressed by this general permit more
frequently than required by this general permit using test procedures approved under 40 CFR
Part 136 or using other test procedures approved by the U.S. Environmental Protection
Agency or using procedures specified in this general permit, the results of this monitoring shall
be included in the calculation and reporting of the data submitted in the DMR or reporting form
specified by the department.
4. Calculations for all limitations which require averaging of measurements shall utilize an
arithmetic mean unless otherwise specified in this general permit.
D. Duty to provide information. The operator shall furnish, within a reasonable time, any
information which the board may request to determine whether cause exists for terminating this
general permit coverage or to determine compliance with this general permit. The board,
department, EPA, or VSMP authority may require the operator to furnish, upon request, such
plans, specifications, and other pertinent information as may be necessary to determine the effect
of the wastes from his discharge on the quality of surface waters, or such other information as
may be necessary to accomplish the purposes of the CWA and the Virginia Stormwater
Management Act. The operator shall also furnish to the board, department, EPA, or VSMP
authority, upon request, copies of records required to be kept by this general permit.
E. Compliance schedule reports. Reports of compliance or noncompliance with, or any progress
reports on, interim and final requirements contained in any compliance schedule of this general
permit shall be submitted no later than 14 days following each schedule date.
F. Unauthorized stormwater discharges. Pursuant to § 62.1-44.5 of the Code of Virginia, except
in compliance with a state permit issued by the department, it shall be unlawful to cause a
stormwater discharge from a construction activity.
G. Reports of unauthorized discharges. Any operator who discharges or causes or allows a
discharge of sewage, industrial waste, other wastes or any noxious or deleterious substance or a
hazardous substance or oil in an amount equal to or in excess of a reportable quantity established
under either 40 CFR Part 110, 40 CFR Part 117, 40 CFR Part 302, or § 62.1-44.34:19 of the Code
of Virginia that occurs during a 24-hour period into or upon surface waters or who discharges or
causes or allows a discharge that may reasonably be expected to enter surface waters, shall
notify the Department of Environmental Quality of the discharge immediately upon discovery of
the discharge, but in no case later than within 24 hours after said discovery. A written report of
the unauthorized discharge shall be submitted to the department and the VSMP authority within
five days of discovery of the discharge. The written report shall contain:
1. A description of the nature and location of the discharge;
2. The cause of the discharge;
Page 20 of 26
3. The date on which the discharge occurred;
4. The length of time that the discharge continued;
5. The volume of the discharge;
6. If the discharge is continuing, how long it is expected to continue;
7. If the discharge is continuing, what the expected total volume of the discharge will be; and
Any steps planned or taken to reduce, eliminate and prevent a recurrence of the present
discharge or any future discharges not authorized by this general permit.
Discharges reportable to the department and the VSMP authority under the immediate reporting
requirements of other regulations are exempted from this requirement.
H. Reports of unusual or extraordinary discharges. If any unusual or extraordinary discharge
including a "bypass" or "upset," as defined in this general permit, should occur from a facility and
the discharge enters or could be expected to enter surface waters, the operator shall promptly
notify, in no case later than within 24 hours, the department and the VSMP authority by telephone
after the discovery of the discharge. This notification shall provide all available details of the
incident, including any adverse effects on aquatic life and the known number of fish killed. The
operator shall reduce the report to writing and shall submit it to the department and the VSMP
authority within five days of discovery of the discharge in accordance with Part III 12. Unusual
and extraordinary discharges include any discharge resulting from:
1. Unusual spillage of materials resulting directly or indirectly from processing operations;
2. Breakdown of processing or accessory equipment;
3. Failure or taking out of service of some or all of the facilities; and
4. Flooding or other acts of nature.
I. Reports of noncompliance. The operator shall report any noncompliance which may adversely
affect surface waters or may endanger public health.
An oral report to the department and the VSMP authority shall be provided within 24 hours
from the time the operator becomes aware of the circumstances. The following shall be
included as information that shall be reported within 24 hours under this subdivision:
a. Any unanticipated bypass; and
b. Any upset that causes a discharge to surface waters.
2. A written report shall be submitted within five days and shall contain:
a. A description of the noncompliance and its cause;
Page 21 of 26
b. The period of noncompliance, including exact dates and times, and if the noncompliance
has not been corrected, the anticipated time it is expected to continue; and
c. Steps taken or planned to reduce, eliminate, and prevent reoccurrence of the
noncompliance.
The department may waive the written report on a case -by -case basis for reports of
noncompliance under Part III I if the oral report has been received within 24 hours and no
adverse impact on surface waters has been reported.
3. The operator shall report all instances of noncompliance not reported under Part III 1 1 or 2 in
writing as part of the SWPPP. The reports shall contain the information listed in Part 111 1 2.
NOTE: The reports required in Part III G, H and I shall be made to the department and the VSMP
authority. Reports may be made by telephone, email, or by fax. For reports outside normal working
hours, leaving a recorded message shall fulfill the immediate reporting requirement. For
emergencies, the Virginia Department of Emergency Management maintains a 24-hour telephone
service at 1-800-468-8892.
4. Where the operator becomes aware of a failure to submit any relevant facts, or submittal of
incorrect information in any report, including a registration statement, to the department or the
VSMP authority, the operator shall promptly submit such facts or correct information.
J. Notice of planned changes.
1. The operator shall give notice to the department and the VSMP authority as soon as possible
of any planned physical alterations or additions to the permitted facility or activity. Notice is
required only when:
a. The operator plans an alteration or addition to any building, structure, facility, or installation
that may meet one of the criteria for determining whether a facility is a new source in
9VAC25-870-420;
b. The operator plans an alteration or addition that would significantly change the nature or
increase the quantity of pollutants discharged. This notification applies to pollutants that
are not subject to effluent limitations in this general permit; or
2. The operator shall give advance notice to the department and VSMP authority of any planned
changes in the permitted facility or activity, which may result in noncompliance with state
permit requirements.
K. Signatory requirements.
1. Registration statement. All registration statements shall be signed as follows:
a. For a corporation: by a responsible corporate officer. For the purpose of this chapter, a
responsible corporate officer means: (i) a president, secretary, treasurer, or vice-president
of the corporation in charge of a principal business function, or any other person who
performs similar policy -making or decision -making functions for the corporation; or (ii) the
manager of one or more manufacturing, production, or operating facilities, provided the
Page 22 of 26
manager is authorized to make management decisions that govern the operation of the
regulated facility including having the explicit or implicit duty of making major capital
investment recommendations, and initiating and directing other comprehensive measures
to assure long-term compliance with environmental laws and regulations; the manager
can ensure that the necessary systems are established or actions taken to gather
complete and accurate information for state permit application requirements; and where
authority to sign documents has been assigned or delegated to the manager in
accordance with corporate procedures;
b. For a partnership or sole proprietorship: by a general partner or the proprietor,
respectively; or
c. For a municipality, state, federal, or other public agency: by either a principal executive
officer or ranking elected official. For purposes of this chapter, a principal executive officer
of a public agency includes (i) the chief executive officer of the agency or (ii) a senior
executive officer having responsibility for the overall operations of a principal geographic
unit of the agency.
2. Reports and other information. All reports required by this general permit, including SWPPPs,
and other information requested by the board or the department shall be signed by a person
described in Part III K 1 or by a duly authorized representative of that person. A person is a
duly authorized representative only if:
a. The authorization is made in writing by a person described in Part III K 1;
b. The authorization specifies either an individual or a position having responsibility for the
overall operation of the regulated facility or activity such as the position of plant manager,
operator of a well or a well field, superintendent, position of equivalent responsibility, or
an individual or position having overall responsibility for environmental matters for the
operator. (A duly authorized representative may thus be either a named individual or any
individual occupying a named position); and
c. The signed and dated written authorization is included in the SWPPP. A copy shall be
provided to the department and VSMP authority, if requested.
3. Changes to authorization. If an authorization under Part III K 2 is no longer accurate because
a different individual or position has responsibility for the overall operation of the construction
activity, a new authorization satisfying the requirements of Part III K 2 shall be submitted to
the VSMP authority as the administering entity for the board prior to or together with any
reports or information to be signed by an authorized representative.
4. Certification. Any person signing a document under Part III K 1 or 2 shall make the following
certification:
"I certify under penalty of law that I have read and understand this document and that this
document and all attachments were prepared in accordance with a system designed to assure
that qualified personnel properly gathered and evaluated the information submitted. Based on
my inquiry of the person or persons who manage the system, or those persons directly
responsible for gathering the information, the information submitted is, to the best of my
knowledge and belief, true, accurate, and complete. I am aware that there are significant
Page 23 of 26
penalties for submitting false information, including the possibility of fine and imprisonment for
knowing violations."
L. Duty to comply. The operator shall comply with all conditions of this general permit. Any state
permit noncompliance constitutes a violation of the Virginia Stormwater Management Act and the
Clean Water Act, except that noncompliance with certain provisions of this general permit may
constitute a violation of the Virginia Stormwater Management Act but not the Clean Water Act.
Permit noncompliance is grounds for enforcement action; for state permit coverage, termination,
revocation and reissuance, or modification; or denial of a state permit renewal application.
The operator shall comply with effluent standards or prohibitions established under § 307(a)
of the Clean Water Act for toxic pollutants within the time provided in the regulations that establish
these standards or prohibitions or standards for sewage sludge use or disposal, even if this
general permit has not yet been modified to incorporate the requirement.
M. Duty to reapply. If the operator wishes to continue an activity regulated by this general permit
after the expiration date of this general permit, the operator shall submit a new registration
statement at least 60 days before the expiration date of the existing general permit, unless
permission for a later date has been granted by the board. The board shall not grant permission
for registration statements to be submitted later than the expiration date of the existing general
permit.
N. Effect of a state permit. This general permit does not convey any property rights in either real
or personal property or any exclusive privileges, nor does it authorize any injury to private property
or invasion of personal rights, or any infringement of federal, state or local law or regulations.
O. State law. Nothing in this general permit shall be construed to preclude the institution of any
legal action under, or relieve the operator from any responsibilities, liabilities, or penalties
established pursuant to any other state law or regulation or under authority preserved by § 510 of
the Clean Water Act. Except as provided in general permit conditions on "bypassing" (Part III U)
and "upset' (Part III V), nothing in this general permit shall be construed to relieve the operator
from civil and criminal penalties for noncompliance.
P. Oil and hazardous substance liability. Nothing in this general permit shall be construed to
preclude the institution of any legal action or relieve the operator from any responsibilities,
liabilities, or penalties to which the operator is or may be subject under §§ 62.1-44.34:14 through
62.1-44.34:23 of the State Water Control Law or § 311 of the Clean Water Act.
Q. Proper operation and maintenance. The operator shall at all times properly operate and
maintain all facilities and systems of treatment and control (and related appurtenances), which
are installed or used by the operator to achieve compliance with the conditions of this general
permit. Proper operation and maintenance also includes effective plant performance, adequate
funding, adequate staffing, and adequate laboratory and process controls, including appropriate
quality assurance procedures. This provision requires the operation of back-up or auxiliary
facilities or similar systems, which are installed by the operator only when the operation is
necessary to achieve compliance with the conditions of this general permit.
R. Disposal of solids or sludges. Solids, sludges or other pollutants removed in the course of
treatment or management of pollutants shall be disposed of in a manner so as to prevent any
pollutant from such materials from entering surface waters and in compliance with all applicable
state and federal laws and regulations.
Page 24 of 26
S. Duty to mitigate. The operator shall take all steps to minimize or prevent any discharge in
violation of this general permit that has a reasonable likelihood of adversely affecting human
health or the environment.
T. Need to halt or reduce activity not a defense. It shall not be a defense for an operator in an
enforcement action that it would have been necessary to halt or reduce the permitted activity in
order to maintain compliance with the conditions of this general permit.
U. Bypass.
1. 'Bypass," as defined in 9VAC25-870-10, means the intentional diversion of waste streams
from any portion of a treatment facility. The operator may allow any bypass to occur that does
not cause effluent limitations to be exceeded, but only if it also is for essential maintenance to
ensure efficient operation. These bypasses are not subject to the provisions of Part III U 2 and
3.
2. Notice.
a. Anticipated bypass. If the operator knows in advance of the need for a bypass, the
operator shall submit prior notice to the department, if possible at least 10 days before the
date of the bypass.
b. Unanticipated bypass. The operator shall submit notice of an unanticipated bypass as
required in Part III I.
3. Prohibition of bypass.
a. Except as provided in Part III U 1, bypass is prohibited, and the board or department may
take enforcement action against an operator for bypass unless:
(1) Bypass was unavoidable to prevent loss of life, personal injury, or severe property
damage. Severe property damage means substantial physical damage to property,
damage to the treatment facilities that causes them to become inoperable, or
substantial and permanent loss of natural resources that can reasonably be expected
to occur in the absence of a bypass. Severe property damage does not mean
economic loss caused by delays in production;
(2) There were no feasible alternatives to the bypass, such as the use of auxiliary
treatment facilities, retention of untreated wastes, or maintenance during normal
periods of equipment downtime. This condition is not satisfied if adequate back-up
equipment should have been installed in the exercise of reasonable engineering
judgment to prevent a bypass that occurred during normal periods of equipment
downtime or preventive maintenance; and
(3) The operator submitted notices as required under Part III U 2.
b. The department may approve an anticipated bypass, after considering its adverse effects,
if the department determines that it will meet the three conditions listed in Part III U 3 a.
Page 25 of 26
V. Upset.
1. An "upset," as defined in 9VAC25-870-10, means an exceptional incident in which there is
unintentional and temporary noncompliance with technology -based state permit effluent
limitations because of factors beyond the reasonable control of the operator. An upset does
not include noncompliance to the extent caused by operational error, improperly designed
treatment facilities, inadequate treatment facilities, lack of preventive maintenance, or
careless or improper operation.
2. An upset constitutes an affirmative defense to an action brought for noncompliance with
technology -based state permit effluent limitations if the requirements of Part III V 4 are met.
A determination made during administrative review of claims that noncompliance was caused
by upset, and before an action for noncompliance, is not a final administrative action subject
to judicial review.
3. An upset does not include noncompliance to the extent caused by operational error,
improperly designed treatment facilities, inadequate treatment facilities, lack of preventative
maintenance, or careless or improper operation.
4. An operator who wishes to establish the affirmative defense of upset shall demonstrate,
through properly signed, contemporaneous operating logs or other relevant evidence that:
a. An upset occurred and that the operator can identify the cause of the upset;
b. The permitted facility was at the time being properly operated;
c. The operator submitted notice of the upset as required in Part III I; and
d. The operator complied with any remedial measures required under Part III S.
5. In any enforcement proceeding, the operator seeking to establish the occurrence of an upset
has the burden of proof.
W. Inspection and entry. The operator shall allow the department as the board's designee, the
VSMP authority, EPA, or an authorized representative of either entity (including an authorized
contractor), upon presentation of credentials and other documents as may be required by law to:
1. Enter upon the operator's premises where a regulated facility or activity is located or
conducted, or where records shall be kept under the conditions of this general permit;
2. Have access to and copy, at reasonable times, any records that shall be kept under the
conditions of this general permit;
3. Inspect and photograph at reasonable times any facilities, equipment (including monitoring
and control equipment), practices, or operations regulated or required under this general
permit; and
4. Sample or monitor at reasonable times, for the purposes of ensuring state permit compliance
or as otherwise authorized by the Clean Water Act or the Virginia Stormwater Management
Act, any substances or parameters at any location.
Page 26 of 26
For purposes of this section, the time for inspection shall be deemed reasonable during regular
business hours, and whenever the facility is discharging. Nothing contained herein shall make an
inspection unreasonable during an emergency.
X. State permit actions. State permit coverage may be modified, revoked and reissued, or
terminated for cause. The filing of a request by the operator for a state permit modification,
revocation and reissuance, or termination, or a notification of planned changes or anticipated
noncompliance does not stay any state permit condition.
Y. Transfer of state permit coverage.
1. State permits are not transferable to any person except after notice to the department. Except
as provided in Part III Y 2, a state permit may be transferred by the operator to a new operator
only if the state permit has been modified or revoked and reissued, or a minor modification
made, to identify the new operator and incorporate such other requirements as may be
necessary under the Virginia Stormwater Management Act and the Clean Water Act.
As an alternative to transfers under Part III Y 1, this state permit may be automatically
transferred to a new operator if:
a. The current operator notifies the department at least 30 days in advance of the proposed
transfer of the title to the facility or property;
b. The notice includes a written agreement between the existing and new operators
containing a specific date for transfer of state permit responsibility, coverage, and liability
between them; and
c. The department does not notify the existing operator and the proposed new operator of
its intent to modify or revoke and reissue the state permit. If this notice is not received, the
transfer is effective on the date specified in the agreement mentioned in Part III Y 2 b.
3. For ongoing construction activity involving a change of operator, the new operator shall accept
and maintain the existing SWPPP, or prepare and implement a new SWPPP prior to taking
over operations at the site.
Z. Severability. The provisions of this general permit are severable, and if any provision of this
general permit or the application of any provision of this state permit to any circumstance, is held
invalid, the application of such provision to other circumstances and the remainder of this general
permit shall not be affected thereby.
Section 12. Inspection logs
(Provide templates for your inspections. Requirements are listed in 9VAC25-880-70, Part II, section B and F.)
Issued — 10/2014 Stormwater Pollution Prevention Plan (SWPPP) Albemarle County
Section 13. Additional Information
Minimum Measure
Construction Site Stormwater Runoff Control
Subcategory
Good Housekeeping/Materials Management
Description of Concrete Washout at
Construction Sites
Concrete and its ingredients
Concrete is a mixture of cement, water, and aggregate material.
Portland cement is made by heating a mixture of limestone and
clay containing oxides of calcium, aluminum, silicon and other
metals in a kiln and then pulverizing the resulting clinker. The
fine aggregate particles are usually sand. Coarse aggregate
is generally gravel or crushed stone. When cement is mixed
with water, a chemical reaction called hydration occurs, which
produces glue that binds the aggregates together to make
concrete.
Concrete washout
After concrete is poured at a construction site, the chutes of
ready mixed concrete trucks and hoppers of concrete pump
trucks must be washed out to remove the remaining concrete
before it hardens. Equipment such as wheelbarrows and hand
tools also need to be washed down. At the end of each work
day, the drums of concrete trucks must be washed out. This is
customarily done at the ready mixed batch plants, which are
usually off -site facilities, however large or rural construction
projects may have on -site batch plants. Cementitious (having
the properties of cement) washwater and solids also come from
using such construction materials as mortar, plaster, stucco,
and grout.
Environmental and Human Health I
Concrete washout water (or washwater) is a slurry containing
toxic metals. It's also caustic and corrosive, having a pH
near 12. In comparison, Drano liquid drain cleaner has a pH
of 13.5. Caustic washwater can harm fish gills and eyes and
interfere with reproduction. The safe pH ranges for aquatic life
habitats are 6.5 — 9 for freshwater and 6.5 — 8.5 for saltwater.
N
Construction workers should handle wet concrete and
washout water with care because it may cause skin irritation
and eye damage. If the washwater is dumped on the ground
(Fig. 1), it can run off the construction site to adjoining roads
and enter roadside storm drains, which discharge to surface
waters such as rivers, lakes, or estuaries. The red arrow in
Figure 2 points to a ready mixed truck chute that's being
washed out into a roll -off bin, which isn't watertight. Leaking
washwater, shown in the foreground, will likely follow similar
Figure 1. Chute
washwater being dumped
on the ground
Figure 2. Chute
washwater leaking from a
roll -off bin being used as a
washout container
paths to nearby surface waters. Rainfall may cause concrete
washout containers that are uncovered to overflow and also
transport the washwater to surface waters. Rainwater polluted
with concrete washwater can percolate down through the
soil and alter the soil chemistry, inhibit plant growth, and
contaminate the groundwater. Its high pH can increase
the toxicity of other substances in the surface waters and
soils. Figures 1 and 2 illustrate the need for better washout
management practices.
Best Management Practice Objectives
The best management practice objectives for concrete washout
are to (a) collect and retain all the concrete washout water and
solids in leak proof containers, so that this caustic material
does not reach the soil surface and then migrate to surface
waters or into the ground water, and (b) recycle 100 percent
of the collected concrete washout water and solids. Another
objective is to support the diversion of recyclable materials from contacted to inquire
landfills. Table 1 shows how concrete washout materials can be
recycled and reused.
Table 1— Recycling concrete washout materials
Concrete Washout Materials
c`
m�
Uses of Recycled Materials
3
Reused to washout additional mixer
truck chutes or drums
x
Reused as a ready mixed concrete
ingredient
x
x°
z
x
Reused as an ingredient of precast
concrete products, e.g., highway
x
x
x
x
x
barriers, retaining wall blocks, riprap
Reused as crushed concrete
products, e.g., road base or fill
x
x
x
x
Reused to pave the yards of ready
mixed concrete plants
x
Returned back to a surface water,
e.g., river, lake, or estuary
xc
a. Fine particles of cementitious material (e.g., Portland cement, slag cement, fly ash,
silica fume)
b. Recyclable, if allowed by the concrete quality specifications
c. Treated to reduce the pH and remove metals, so it can be delivered to a municipal
wastewater treatment plant, where it is treated further and then returned to a natural
surface water
Washwater recycling, treatment, disposal
Washwater from concrete truck
chutes, hand mixers, or other
equipment can be passed through
a system of weirs or filters to remove
solids and then be reused to wash
down more chutes and equipment
at the construction site or as an
ingredient for making additional
concrete. A three chamber washout
filter is shown in Figure 3. The first
stage collects the coarse aggregate.
The middle stage filters out the
small grit and sand. The third stage
has an array of tablets that filter
Figure 3. Concrete washout
filter
out fines and reduces the pH. The filtered washwater is then
discharged through a filter sock. An alternative is to pump the
washout water out of the washout container (Fig 4) and treat
the washwater off site to remove metals and reduce its pH,
so it can be delivered to a publicly owned treatment works
(POTW), also known as a municipal wastewater treatment plant,
which provides additional treatment allowing the washwater
to be discharged to a surface water. The POTW should be
about any pretreatment
requirements, i.e., the
National Pretreatment
Standards for Prohibited
Dischargers (40CFR 403.5)
before discharging the
washwater to the POTW.
The washwater can also
be retained in the washout
container and allowed to
Figure 4. Vacuuming washwater out of a
washout container for treatment and reuse
evaporate, leaving only the hardened cementitious solids to be
recycled.
Solids recycling
The course aggregate materials that are washed off concrete
truck chutes into a washout container can be either separated
by a screen and placed in aggregate bins to be reused at
the construction site or returned to the ready mixed plant and
washed into a reclaimer (Fig. 5). When washed out into a
reclaimer, the fine and course aggregates are separated out
and placed in different
piles or bins to be reused
in making fresh concrete.
Reclaimers with settling
tanks separate cement
fines from the washwater,
and these fines can also
be used in new concrete
unless prohibited by the
user's concrete quality
specifications.
Figure 5. Ready mixed truck washing
out into a reclatmer
Hardened concrete recycling
When the washwater in a construction site concrete washout
container has been removed or allowed to evaporate, the
hardened concrete that remains can be crushed (Fig. 6)
and reused as a construction material. It makes an excellent
aggregate for road base and can be used as fill at the
Figure 6. Crushed concrete stockpile and
crusher
construction site or
delivered to a recycler.
Concrete recyclers can
be found at municipal
solid waste disposal
facilities, private
recycling plants, or large
construction sites.
Wet concrete recycling
Builders often order a little more ready mixed concrete than
they actually need, so it is common for concrete trucks to
have wet concrete remaining in their drum after a delivery. This
unused concrete can be returned to the ready mixed plant and
either (1) used to pour precast concrete products (e.g., highway
barriers, retaining wall blocks, riprap), (2) used to pave the
ready mixed plant's yard, (3) washed into a reclaimer, or
(4) dumped on an impervious surface and allowed to harden,
so it can be crushed and recycled as aggregate. Unused wet
concrete should not be dumped on bare ground to harden at
construction sites because this can contribute to ground water
and surface water contamination.
Washout Containers
Different types of washout containers are available for
collecting, retaining, and recycling the washwater and solids
from washing down mixed truck chutes and pump truck
hoppers at construction sites.
Chute washout box
A chute washout box is mounted on the back of the ready
mixed truck. If the truck has three chutes, the following
procedure is used to perform the washout from the top down:
(1) after the pour is completed, the driver attaches the extension
chute to the washout box, (2) the driver then rotates the main
chute over the extension chute (Fig. 7) and washes down the
hopper first then the main chute, (3) finally the driver washes
down the flop down chute and last the extension chute hanging
on the box. All washwater and solids are captured in the box.
Figure 7. Chute washout box
After the wash down,
washwater and solids are
returned to the ready mixed
plant for recycling. A filter
basket near the top of the
washout box separates out
the coarse aggregates so
they can be placed in a
bin for reuse either at the
construction site or back at
the cement plant.
Chute washout bucket and pump
After delivering ready mixed concrete and scraping the last of
the customer's concrete down the chute, the driver hangs a
washout bucket shown in Figure 8 (see red arrow) on the end of
the truck's chute and secures the hose to insure no leaks. The
driver then washes down
the chute into the bucket to
remove any cementitious
material before it hardens.
After washing out the chute,
the driver pumps (yellow
arrow points to the pump)
the washwater, sand, and
other fine solids from the
bucket up into the truck's
drum to be returned to the
Figure 8. Chute washout bucket and
PUMP
ready mixed plant, where it can be washed into a reclaimer.
A removable screen at the bottom of the washout bucket
prevents course aggregate from entering the pump. This
course aggregate can also be returned to the plant and added
to the coarse aggregate pile to be reused. All the materials are
recycled.
Hay bale and plastic washout pit
A washout pit made with hay bales and a plastic lining is shown
in Figure 9. Such pits can be dug into the ground or built above
grade. The plastic lining should be free of tears or holes that
would allow the washwater to escape (Fig. 10). After the pit is
used to wash down the chutes of multiple ready mixed trucks
and the washwater has evaporated or has been vacuumed off,
the remaining hardened solids can be broken up and removed
from the pit. This process may damage the hay bales and
plastic lining. If damage occurs, the pit will need to be repaired
and relined with new plastic. When the hardened solids are
removed, they may be bound up with the plastic lining and have
to be sent to a landfill, rather than recycled. Recyclers usually
accept only unmixed material. If the pit is going to be emptied
and repaired more than a few times, the hay bales and plastic
will be generating additional solid waste. Ready mixed concrete
bale and plastic
Figure 10. Leaking
washout pit that
has not been well
maintained
trucks can use hay bale washout pits, but concrete pump
trucks have a low hanging hopper in the back that may prevent
their being washed out into bale -lined pits.
Vinyl washout container
The vinyl washout
container (Fig. 11) is
portable, reusable, and
easier to install than a
hay bale washout pit.
Figure 11.Vinylwashoutpitwithfilterbag The biodegradable filter
bag (Fig. 12) assists in
extracting the concrete solids and prolongs the life of the vinyl
container. When the bag is lifted, the water is filtered out and
the remaining concrete solids and the bag can be disposed of
together in a landfill, or the hardened concrete can be delivered
to a recycler. After the solids have been removed several times
and the container is full of washwater, the washwater can be
allowed to evaporate, so the container can be reused. The
washwater can be removed more quickly by placing another
filter bag in the container
and spreading water gelling
granules evenly across the
water. In about five minutes,
the water in the filter bag will
turn into a gel that can be
removed with the bag. Then
the gel and filter bag can be
disposed to together.
Metal washout container
Figure 12. Extracting the concrete
solids or gelled washwater
The metal roll -off bin (Fig. 13) is designed to securely contain
concrete washwater and solids and is portable and reusable.
It also has a ramp that allows concrete pump trucks to wash
out their hoppers (Fig. 14). Roll -off providers offer recycling
services, such as, picking up the roll -off bins after the
washwater has evaporated and the solids have hardened,
replacing them with
empty washout bins, and
delivering the hardened
concrete to a recycler
(Fig. 15), rather than a
landfill. Some providers will
vacuum off the washwater,
treat it to remove metals and
reduce the pH, deliver it to a
wastewater treatment plant
for additional treatment and
Figure 13. Mixer truck being washed out
into a roll -off bin
subsequent discharge to a surface water. Everything is recycled
or treated sufficiently to be returned to a natural surface water.
mp truck using the
out into a roll -off bin
Figure 15.
Delivering
hardened Concrete
to a recycler
Another metal, portable, washout container, which has a
rain cover to prevent overflowing, is shown in Figure 16. It is
accompanied by an onsite washwater treatment unit, which
reduces the pH and uses a forced weir tank system to remove
the coarse aggregate, fine aggregate, and cement fines. The
washwater can
then be reused at
the construction
site to wash
out other mixer
truck chutes
and equipment. Figure 16. Washout container with a rain coverand
The solids are onsite washwater treatment
allowed to harden
together and can
be taken to a concrete
recycler (Fig. 17) to be
crushed and used as
road base or aggregate
for making precast
products, such as
retaining wall blocks. All Figure 17. Delivering hardened concrete
materials are recycled. to a recycler
Siting Washout Facilities
Concrete washout facilities, such as washout pits and vinyl
or metal washout containers, should be placed in locations
that provide convenient access to concrete trucks, preferably
near the area where concrete is being poured. However they
4
should not be placed within 50 feet of storm drains, open
ditches, or waterbodies. Appropriate gravel or rock should
cover approaches to concrete washout facilities when they are
located on undeveloped property. On large sites with extensive
concrete work, washouts should be placed at multiple locations
for ease of use by ready mixed truck drivers. If the washout
Reference
NRMCA 2009. Environmental Management in the Ready
Mixed Concrete Industry. 2PEMRM. 1st edition. By Gary M.
Mullins. Silver Springs, MD: National Ready Mixed Concrete
Association.
facility is not within view from the pour location, signage will be
needed to direct the truck drivers. Websites and Videos
Construction Materials Recycling Association
Operating and Inspecting Washout www.concreterecycling.org
Facilities
Concrete washout facilities should be inspected daily and after
heavy rains to check for leaks, identify any plastic linings and
sidewalls have been damaged by construction activities, and
determine whether they have been filled to over 75 percent
capacity. When the washout container is filled to over
75 percent of its capacity, the washwater should be vacuumed
off or allowed to evaporate to avoid overflows. Then when the
remaining cementitious solids have hardened, they should be
removed and recycled. Damages to the container should be
repaired promptly. Before heavy rains, the washout container's
liquid level should be lowered or the container should be
covered to avoid an overflow during the rain storm.
Educating Concrete Subcontractors
The construction site superintendent should make ready mixed
truck drivers aware of washout facility locations and be watchful
for improper dumping of cementitious material. In addition,
concrete washout requirements should be included in contracts
with concrete delivery companies.
National Ready Mixed Concrete Association
www.nrmca.org
National Ready Mixed Concrete Research and Education
Foundation
www.rmc-foundation.org
Additional information and videos on concrete washout
containers and systems can be found by a web search for
"concrete washout."
Photograph Credits
Figures 1, 2. Mark Jenkins, Concrete Washout Systems, Inc.
Figure 3. Mark Shaw, Ultra Tech International, Inc.
Figure 4. Mark Jenkins, Concrete Washout Systems, Inc.
Figure 5. Christopher Crouch, CCI Consulting
Figure 6. William Turley, Construction Materials Recycling Association
Figure 7. Brad Burke, Innovative Concrete Solutions, LLC
Figure 8. Ron Lankester, Enviroguard
Figures 9, 10. Mark Jenkins, Concrete Washout Systems, Inc.
Figures 11, 12. Tom Card, RTC Supply
Figures 13, 14, 15. Mark Jenkins, Concrete Washout Systems, Inc.
Figures 16, 17. Rick Abney Sr., Waste Crete Systems, LLP
Disclaimer
Please note that EPA has provided external links because they provide additional information that may be useful or interesting. EPA cannot attest to the
accuracy of non -EPA information provided by these third -party websites and does not endorse any non -government organizations or their products or services.