Loading...
HomeMy WebLinkAboutSUB201700140 Assessment - Groundwater 2021-03-09 Old Trail Block 22 – Pipe Re-inspection Summary Date: March 9, 2021 Summary: Roudabush Pipe Inspection Services conducted a video inspection on 2/26/21 of Old Trail block 22 at the request of March Mountain. The purpose of this inspection was to verify proper installation and function of the installed Storm Sewer to VDOT standards. The facility was inspected with a Pearpoint P350 wheeled crawler camera with a pan/tilt/zoom Camera. Wincan pipe inspection software was used to document the inspections and produce an inspection report of the SWM facility. The inspection standards used were NASSCO PACP and VDOT VTM 123. Findings: The post cleaning inspection identified one minor area of sediment (approximately 1’ to 2’ LF) remaining that did not affect the inspection or functioning of the pipe. These pipes appear to meet VDOT standards and should be accepted accordingly. Please find a summary of inspections on attachment A. Please contact kraine@roudabush.com for any questions or a link to the inspection videos. Respectfully, Kent C Raine NASSCO Cert # U-0920- 703010383 Roudabush, Gale, and Associates, INC Pipe Inspection Services ATTACHMENT A Start End 1 Storm 8 7 14.3 2/5/2021 Pipe OK 15 HDPE 1 2 Storm 2 1 36.9 1/9/2019 Pipe Ok 24 HDPE 1 3 Storm 10 11 70.6 2/5/2021 Deposits (1' to 2') Pipe OK 15 HDPE 2 4 Storm 3.1 3 38.9 1/9/2019 Pipe OK 18 HDPE 1 5 Storm 10 9 59.5 1/9/2019 Pipe OK 15 HDPE 1 6 Storm 3.1 3.2 153.8 1/9/2019 Pipe OK 15 HDPE 1 7 Storm 12 11 15.2 1/9/2019 Pipe OK 15 HDPE 1 8 Storm 2 3 263.6 1/9/2020 Pipe OK 18 HDPE 1 9 Storm 1 OUT 39.2 1/9/2019 Pipe OK 24 HDPE 1 10 Storm 5 6 64 1/9/2019 Pipe OK 15 HDPE 1 11 Storm 4 3 166.2 1/9/2019 Pipe OK 18 HDPE 1 12 Storm 7 6 92.9 3/3/2021 Pipe OK 15 HDPE 3 13 Storm 12 13 15.2 1/9/2020 Pipe OK 15 HDPE 1 14 Storm 4 5 119.6 1/9/2020 Deposits in manhole, pipe OK 15 HDPE 1 15 Storm 3.1 9 75.7 1/9/2020 Pipe OK 15 HDPE 1 16 Storm 4 4.1 48.9 1/9/2020 Pipe OK 15 HDPE 1 total 1274.5 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Comments N/A Old Trail Block 22 Size (in)MaterialStorm/ Culvert Test Section # Total # Inspections Structure Direction Length Inspected Recommended RepairDate Downstream Downstream Downstream Upstream Upstream Downstream Downstream Downstream Upstream Upstream Upstream Downstream Upstream Upstream Upstream Upstream