Loading...
HomeMy WebLinkAboutSUB202000131 Review Comments Appeal to BOS 2021-08-13 ,�Ji ey<;•; J � V ` , �J_ ." .,-:. County of Albemarle Department of Community Development Memorandum To: Rob Cummings, Kirk Hughes & Associates From: Tori Kanellopoulos - Senior Planner Division: Planning Services Date: August 13, 2021 REV1 Subject: SUB202000131 — Lochlyn Hill Phase IV— Final Subdivision Plat, dated last revision date 04/11/2021 The County of Albemarle Planning Division will grant or recommend approval of the Final Plat referenced above once the following comments have been addressed: [Each comment is preceded by the applicable reference, which is to the Subdivision/Zoning Ordinances unless otherwise specified.] If no action is taken within 6 months of receiving these review comments, the application will be deemed withdrawn. Planning (Tori Kanellopoulos): 1. 14-317 Private maintenance agreements. Private maintenance agreements are needed for the following private improvements and must meet the requirements of 14-317. A template and checklist, to be filled out by the applicant, are attached. a. Required improvements that must be covered by a private maintenance agreement: private alleys; open space; and private sanitary sewer. b. REV 1: Comment remains. If there are already existing private maintenance documents for the Lochlyn Hill Development, those can be amended to include these required private improvements as well. The County still needs to review the existing documents and amendment to ensure 14-317 is met. 2. .: plat REV 1: Addressed. 3. ?(A)(4)(5) Easement information. SS/E-2 needs to be clarified. Part of this ient is existing, however the portion shown along Lots 145-148 appears to be new. iown as both existing conditions and proposed easements. Only existing �ents should be shown on the existing conditions sheet; the revised easement 4. REV 1: 14-302(A)(4)(5) Easement information. Include on Sheet 1 as well that the ACSA water and sewer easements are also 'dedicated to public use'. 5. .. �__,._. . .,_� -rr-_, ._ _., __ �__,._ __. _,.__._ _' '�"...__..� .___.__ __ ___... REV 7: Addressed. 6. ?(A)(7) Existing lot lines. A dimension for the existing parcel boundaries appears to 7. ?(B)(8) Setbacks. The minimum side setback for R-4 per 18-4.19 is 5' minimum. REV 1: Addressed. 8. 3(D) Acreage. Include the acreage of each existing lot (on Sheet 2) that is part of al 4.4595 acres being adjusted/subdivided. REV 2: Addressed. 9. 10. REV 1: 14-303(0)/14-302(A)(15) Owner information. Include the address of each owner. 11. �zt„ �. ,,uu�����u. 12. 1.3 R-4 and bonus factors. Label the affordable units required for this R-4 cluster 13. Comment: Please note the City of Charlottesville will need to sign the final plat. 14. Additional applications: The following applications and approvals are required prior to final site plat approval: a. 14�03, 14-235, 14-311 and 18�.6.1 Road Plan approval will be required prior to final plat approval. a. REV 1: Comment remains. b. 18-32.7.4.1: Approval of a VSMP Plan is required prior to final plat approval. See Engineering comments. Coordinate directly with David James (diames2Ca�albemarle.orq). SWM facilities appear to be off-site and located in the City of Charlottesville. It appears previous approval for Phase 1 may have required coordination with DCR. a. REV 1: Comment remains. Engineering (David James): 1. The lot numbers should match the site plan lot numbers for consistency. a. REV 1: Currently not addressed. a. REV 1: Addressed. 3. Correct plat to reflect curb radius change of 25' in the cul-de-sac per requested change on the site plan review. z REV 1: Add�����d. 5. Record plat and drainage deed. a. REV 1: Comment remains 6. REV 1: Submit an approved SWM/ESC plan for compliance with Sec. 14-311. 7. REV 1: Note: Waiver request for dead end alley has not been approved (A road plan comment that needs to be addressed prior). VDOT (Adam Moore): 1. Approved road plans meeting SSAR, and in compliance with the VDOT Road Design Manual are required prior to plat approval. See attached letter dated July 20, 2021. ACSA (Richard Nelson): 1. Comments will be sent directly to applicant. RWSA (Dyon Vega) 1. RWSA has reviewed the Lochlyn Hill Ph IV Final Plat with the last revision dated 4/11/21 and has no further comments. Fire/Rescue (Howard Lagomarsino): Fire apparatus access roads are required for each building. These roads must meet the following requirements, generally at site plan and road plan phases: 1) Fire apparatus access roads shall extend to within 150 feet (45 720 mm) of all portions of the facility and/or all portions of the exterior walls of the first story of the buildings as measured by an approved route around the exterior of the buildings or facility. 2) An emergency/fire vehicle access road/route needs to provide a suitable surface to sustain the weight of emergency apparatus weighing up to 85,000 Ibs. 4) An emergency/fire vehicle access road/route needs to provide an unobstructed travel way width of 20 ft. if buildings/structures are under 30 feet tall and 26 ft. if buildings/structures are over 30 feet tall 5) Emergency/fire vehicle access roads need to be clear of overhead obstructions at 13 ft 6 in. and below 6) To accommodate fire apparatus, turn radii serving fire apparatus access must be a minimum of 25 ft. 7) To ensure that parking does not obstruct the emergency apparatus travel way as described above, any parking must be designed to and/or no parking signs are required to maintain the required unobstructed travel way widths 8) Any dead-end longer than 150 ft requires an approved turn around for emergency apparatus Looking at the plat, there appear to be challenges with meeting the distance, width and turn requirements for lots 149 through 156. These appear on the plat to be attached homes making reaching all sides of the ground floor from the fire apparatus road challenging which brings the alley easements into consideration. The easement for their width is adequate, so long as it does not get reduced below 20 ft travelway, unobstructed, but the cul de sac easement does not seem adequate for a 96 ft diameter as required. Please clarify intentions of the alleys and how access to all sides of these lots is obtained in regards to an appropriate fire apparatus access road. Inspections (Betty Slough): 1. Add the following note to the general notes page: a. Retaining walls greater than 3 feet in height require a separate building permit. Walls exceeding 4 feet in height require a stamped engineered design also. Walls require inspections as outlined in the USBC. 2. Add the following note to the general notes page: a. ALL water lines, sewer lines, and fire lines from the main to the structure MUST have a visual inspection performed by the building department. 3. Add the following note to the general notes page: a. Where the flood level rims of plumbing fixtures are below the elevation of the manhole cover of the next upstream manhole in the public sewer, the fixtures shall be protected by a backwater valve installed in the building drain, branch of the building drain or horizontal branch serving such fixtures. Plumbing fixtures having flood level rims above the elevation of the manhole cover of the next upstream manhole in the public sewer shall not discharge through a backwater valve. 4. Note to developer: Due to required distances from lot lines and structures as required by the NFPA, underground propane tanks may be prohibited. Plan accordingly. E911 (Elise Kiewra): 1. See attached comments dated July 28, 2021. Evans Alley and Ellison Alley road names need to be changed. Please contact Tori Kanellopoulos in the Planning Division at vkanellopoulos(a�albemarle.orq or 434-296-5832 ext. 3270 for further information.