HomeMy WebLinkAboutSDP200000024 Other 2000-05-08 —A o A teltAgi friinto COUNTY OF ALBEMARLE Department of Engineering&Public Works MEMORANDUM TO: Yadira Amarante, Planner FROM: -Steven Snell, Engineer DATE: 8 May 2000 RE: North Fork Research Park, District#2,Building#1 &#2 Critical Slopes Waivers The request for a waiver to develop on areas of critical slopes for the plan received 6 April 2000 has been reviewed. The critical slope areas are along Lewis and Clark Drive and along the southwestern section of this plan. Critical slopes make up 0.76 acres of the site's 6.69 acres, or 11% of the site area. The plan shows 100% of the critical slopes being disturbed, or 0.76 acres. The disturbance is in the form of fill and Building#1 being place over the critical slopes. After grading, newly constructed critical slopes would exist on 0.31 acres, or 4.6% of the site area. Below, each of the concerns of section 18-4.2 is addressed by Engineering: Rapid and/or large scale movement of soil and rock; Proper construction of slopes will prevent movement of soil and rock. Excessive stormwater run-off; The stormsewer system shown on the site plan will prevent excessive runoff from, or on, critical slopes. Siltation of natural and man-made bodies of water; County inspection and bonding of erosion control measures will address excessive siltation during construction. Proper vegetative stabilization will prevent long term siltation. Loss of aesthetic resource; This is a pastoral slope and grass-lined ditch located within a commercial development. A greater travel distance of septic effluent This site is serviced by public sewer, so septic effluent is not an issue. Based on the review above, there are no engineering concerns which prohibit the approval of the critical slope waiver. Please contact me if you have questions or require additional information. Copy: file File: North Fork SDP 00-24 csw.doc sU n uNAll Wt.. COUNTY OF ALBEMARLE Department of Engineering&Public Works MEMORANDUM TO: Yadira Amarante,Planner FROM: Steven Snell, Engineer DATE: 8 May 2000 RE: North Fork Research Park, District#2, Building#1 &#2 Curvilinear Parking Modifications The proposed parking configuration on the preliminary plan received on 6 April 2000 has been , reviewed. A Curvilinear Parking Waiver request letter was received for this plan. The plan shows the proposed parking lot west of Lewis and Clark Drive and adjacent to the proposed building#1 and building#2. This lot has 606 spaces. The curvilinear parking consist of 17 spaces located within the proposed parking lot. The spaces are 9 feet wide by 16 feet long with a 2-foot overhang. The aisles are 24 feet wide. These dimensions meet the minimum size requirements listed in section 18-4.12.6.5 of the County Code. The minimum sight distance of 100 feet [18-4.12.6.3] is met with the proposed layout. The curvilinear parking is along a gradual curve that is designed to conform to site conditions Based on the review above, the Engineering Department recommends approval of the proposed parking configuration. Please contact me if you have questions or require additional information. Copy: file File: North Fork SDP-24 cpw.doc O► Draper Ader; ,associates L� �s -, O 4RAG�J�f�i]O1 iuLaf Engineering•Surveying•Environmental Services 8090 Villa Park Drive Richmond,Virginia 23228 DATE Eh 1 00 JOB NO. R Phone 804/264-2228 ATTENTION Fax 804/264-8773 M s "AD I,2i AMA-P_A4,J T TO C RE. ova--y c c A t...F ivv42,L..E Oe -,2_,1� SDP DO- nZ4- De' � I �j,3e.11t-3Ck T- 0 . ` 1()k MC ( WTI(2 21D , t l2 M 2I8 CIA 11.OVV eSU I k,c,G. t V A zz \o2 -45)6 ZOLA - . 9C0 - 5723 WE ARE SENDING YOU XAttached ❑ Under separate cover via the following items. ❑ Shop drawings ❑ Prints ❑ Plans ❑ Samples ❑ Specifications ❑ Copy of letter ❑ Change order ❑ COPIES DATE NO DESCRIPTION I If °'xI7 `' c pt , c 3 R EV ISM A6 r�-o,6o� -pi_.�S ( pG J_ of -SO' w 6 �M MC-r �S.3- , I Cg-irIcm JuoPE Li4tV€2 �eQVC-Sr 1 , ( itLINIE ip,tkPv-rl0e. WA-w Pc-rzv s -- 1 _ ��ucTio� 1i . i� �PACEJS VOA-I\I 12eaJ-r- THESE ARE TRANSMITTED as checked below. ❑ For approval ❑ Approved as submitted ❑ Resubmit copies for approval ❑ For your use ❑ Approved as noted ❑ Submit copies for distribution A. requested 0 Returned for corrections ❑ Return corrected prints O For review and comment ❑ ❑ FOR BIDS DUE. 19 _ ❑ PRINTS RETURNED AFTER LOAN TO US REMARKS RECWD PLANNING AND COMMUNITY DEVbLOPMENT COPY TO [ UE S • —1>I0L-1&‘ ?'914 -17(---- If enclosures are not as noted,kindly notify us at once. site W,P s v s.....I'M'..I m's, vHU/,'''aS."1", :R::''',.i'RU'b':V.,V . 1,7 ; , FAX TRANSMITTAL ''`` DATE: 4-f Z1100 TEV1E: Draper Aden Associates \ 8090 Villa Park Drive `' TO: �� 12� ti Richmond,Virginia 23228 804/264-2228 COMPANY: AL/36MA-Q L-E Fax: 804/264-8773 FAX NO: BcD¢ 9-12-- 4035 FROM: i S i-k-O S'� Blacksburg Office: (Richmond Office) , 2206 South Main Street `' No. OF FA,GES Blacksburg,Virginia 24060 r; 540/552-0444 INCLUDING COVER SHEET Fax: 540/552-0291 '. COMMENTS: Comprehensive Engineering Services 4a Y • Water and Wastewater c s • Solid Waste Management "' and Planning ''.y . . . .. .. .. .. 17 • Environmental Services to Surveying '!x1 • • Industrial, Commercial& Residential Land Development '-' Engineering lii • Geotechnical and '''' ,, Construction Services . . .. sli • Telecommunications •, Engineering "WE EXIST TO HELP OUR CLIENTS SUCCEED" 1 V U4/Ll/UU 14:L4 ritA 8U4 ZOLI 1J LAtil-rrc ALMA `ADD Ul.Lit LY_Juu,c fir 2 roe—Ds' . rde s odnI w , it+lall]C9lfall Sdra'ii .' April 24,2000 dal%G,L(L:I.tap Ul U A R 15 C:;15.C,IIk• Ms- Yadira Annarante, Planner County of Albemarle Department of Planning and Community Service 401 McIntire Road,Room 218 Charlottesville,VA 22902-4596 RE: North Fork Research Park - District#2, Building#1 &#2 (SDP 00-024) Critical Slope Disturbance Waiver Request Dear Ms. Aanarante: As you are aware, the above referenced project proposes to disturb areas that have been identified as Critical Slopes. These areas are shown on the Demolition & Erosion Control Plan (Drawing C-4). This disturbance is not currently permitted according to the County of Albemarle Zoning Ordinance [4.2]. As a representative of the owner, The University of Virginia Real Estate Foundation, Draper Aden Associates would like to request that a waiver be granted allowing the disturbance of these critical slope areas. Attached is a reduced size copy of our Demolition and Erosion Control Plan showing the proposed disturbances. The areas of disturbance shaded on Drawing C-4 total 0.76 acres of the 6.69-acre site. Of the 0.76 acres of critical slopes that are being disturbed, approximately 0.50 acres were created through previous land disturbance. The previous land disturbing activities were the construction of Lewis& Clark Drive. The new critical slope disturbance totals approximately 11% of the total site disturbance. The grading plan proposes to construct new critical slope area totaling approximately 0.31-acres. These slopes have been created in areas where future buildings could be constructed, which would ultimately eliminate the steep slope. The site development plan also identifies that this slope is to receive ground cover rather than grass cover. This will reduce the level of maintenance required for the slope and also provide a higher level of surface slope stability. The slope that the fill material is to be placed on is an engineered slope that was constructed with the construction of Lewis and Clark Drive. The surface of the fill will be an impervious asphalt parking lot. The parking lot will have a storm sewer system constructed to collect and carry the runoff to the base of the fill slope. This construction will prevent excessive storm water runoff from impacting the integrity of the fill slope. Blacksburg,Virginia•Richmond,Virginia•Raleigh/Durham,North Carolina U4/Lr/UU 14:G4 rit.& OU4 A04 Oita vzitrnr Aural taaav,-,u11nn7 Ms. Yadira Amarante Page 2 April 24,2000 Additionally, as was previously mentioned, the slope will be benched and stabilized with natural ground cover. The proposed erosion control measures for the grading of the site involves a sediment basin located at the southwest corner of the site. It has been proposed to'use this sediment basing for future construction on the site. As a result of this, the sediment basin has been sized for managing the storm water runoff from the entire site. This means that the sediment basin will exceed the minimum wet and dry storage volume requirements for this project. This will provide a higher efficiency in removal of sediment from storm water runoff. This area is currently a grass and wooded area, which has been partially disturbed from previous land disturbing activities. The grading of the site will not diminish the aesthetic resources of the site, as the scenic vistas and natural bodies of water are not being disturbed_ The travel distance for septic effluent does not cause concern because this site is serviced by a public sewer system. The sewer system for the proposed building will connect to an - existing sewer that was installed as part of the Lewis&Clark Road construction. As has been outlined above, this construction has been designed to reduce the potential negative impacts to the environment anti enhance the percentage of developable area within District#2. If you should have any questions or cotnients regarding any of the above listed information,please feel free to give Jeff Lighthiser or myself a call. Sincerely, DRAPER ADEN ASSOCIATES, INC NULIA*119-it M OWAI— Christopher IVI. Shust, MS Project Manager I3:\projccts\R99\12.991301R99130-21\oorres0crostncrilsl.Joc U4/LI/UU 14:AD i'I A t'SU4 LO4 Oita PZUU ',A ALMA A VViHIZO ear. uu4 a. DraperAden en sso dal s E.nginexrirt,• Su,-'e'yirig,A "LPV14.O1rL1 fll Seni.,t April 24,2000 80er1!1 ill:e fail;frier [Zic111e10dd,Yirgi;eia ::32M8 (804)2,6a-232 4' i nr 1N11.Ia 2618773 dao,,Wkia:t.con3 1. q'. ,.dae,coer Ms. Yadira Amarante, Planner County of Albemarle , Department of Planning and Community Service 401 McIntire Road,Room 218 Charlottesville,VA 22902-4596 RE: North Fork Research Park District#2,Building#1 &#2 (SDP 00-024) Curvilinear Parking Waiver Request Dear Ms. Arnarante: As you are aware, the proposed development of this site includes the construction of curvilinear parking spaces in the parking lot located to the north of the proposed building #1. As a representative of the owner, The University of Virginia Real Estate Foundation, Draper Aden Associates would like to request that a waiver be granted allowing for the construction of curvilinear parking on this project. The curvilinear parking has been proposed at this site to allow for the maximum level of efficiency within the parking lot. The reason for the proposed curvilinear parking is that it allows the parking lot design to follow the curve in the road at Lewis & Clark Drive. The curvilinear parking was appropriate both aesthetically and from an engineering perspective. The parking has been designed with sufficiently large radii to provide the maximum possible sight distance within.the parking lot. These parking spaces comprise 17 of the 606 total spaces associated with this development. The curvilinear parking spaces provide a minimum stall width of 9' and a minimum stall depth of 18'. The travel aisles through the curvilinear parking areas are 24' in width_ These dimensions meet the requirement of [4.12.6.3] of the County Code. The minimum sight distance outlined in [4.12.6.3] is also met with the proposed layout. Sincerely, DRAPER ADEN ASSOCIATES, INC DAA6L66/6A Ait /4411044 Christopher M. Shust,MS Project Manager H:\Projects\R99\R9913O\R09130-21\corl'csp\crostocurvil.doe Blacksburg,Virginia•Rielunond.Virginia•Raleigh/Durhtun.North Carolina 04/27/00 14:15 FAX 804 264 8773 DKAYJY( AUFN AS8UU1A1'iS LJuu5 YE 1,3 ]E 5-%r, rSC, i �,.m Ir r'"I l�S .drl A"1't�`a r 7' "s . 4 !1 ra u "rh r� r�14 ~i.S a4.Pl ; �iC�a� d.sY"„iru:ca;. . ..."'I'1'91),4 .:I me21; :ar,•I'"9t1'F - st r vet:a.Park nrll • Richmond.`, (;30 )26,t-Z1_„4 r rt 'sh+ Mr''3 LI.ea al't I .coma•4L 'a„ a.:uA.c e:> April 27, 2000 Yadira Amarante, Planner County of Albemarle Department of Planning and Community Service 401 McIntire Road, Room 218 Charlottesville, VA 22902-4596 RE: North Fork Research Park District#2,Building#1 &#2 (SDP 00-024) Request to Reduce Service Space Requirement Dear Yadira: As you are aware, the above referenced project proposes to construct two separate buildings on the site. At the present time, a total of 11 Load Spaces are required according to the County of Albemarle Zoning Ordinance [4.12.7.4(b)]. Currently, 7 spaces are required for Building #1 and 4 spaces are required for Building #2. As a representative of the owner, The University of Virginia Real Estate Foundation, we would like to request that a waiver be granted allowing a reduction in the total number of Loading Spaces required for this project. We are proposing a total of 8 spaces: 4 Loading Spaces for Building #1, and 4 Loading Spaces for Building#2. This waiver is being requested due to the zoning and uses of the buildings that have been proposed. The buildings are to be comprised of office and lab spaces. These uses do not typically require a large volume of delivery and maintenance vehicles that would mandate a higher number of service loading spaces. Please feel free to give Mr. Jeff Lighthiser or myself a call if you should have any questions or comments. Sincerely, DRAPER ADEN ASSOCIATES, INC bit1.4/1161j11-- itjt°P Christopher M. Shust Project Manager Blacksburg.Virginia•Richmond,Virginia•Raleigh/Durham,North Carolina U4/Lb/UU li:04 ritA 0U4 404 OI IJ •c+ _� • .. Vrn!'•;q;.i;?i,;;,,;:0vr"::::11/fm'nfi,]{id1il;•iil'1p,:. ;}i;,+;,?r:{:r 1' = q FAX TRANSMITTAL DATE: 4 I.21 ip) TIME: S 00 Draper Aden Associates 4-�I RA A M ki TS- 8090 Villa Park Drive TO: Richmond,Virginia 23228 8041 264-2228 COMPANY: M'A LE C�� �7�,/I�.. • Fax: 804/264-8773 `', FAX NO:FAX 912- 403S FRAM: $ ti-o ` - Blacksburg Office: (Richmond Office) , 2206 South Main Street Blacksburg,Virginia 24060 No. OF PAGES z 540/552-044-4 +Y INCLUDING COVER SHEET :-r Fag: 540/552-0291 COMMENTS: YA-DI lapk Comprehensive Dew -tom 2C�.0 ' Engineering r, C s, Services • Water and Wastewater itl,1 • 1, • Solid Waste Management :1 and Planning i'' • Environmental Services ;: ® Surveying Yx, e Industrial, Commercial& 'ti Residential Land "E Development ;4. Engineering 4 e Geotechnical and d Construction Services x Y Telecommunications ''� Engineering `', "WE EXIST TO HELP OUR CLIENTS SUCCEED" U4/ZD/UU 1J:04 rah. OV4 LO4 8l lJ LAnrnn Aral tiaak,,,inic10 ► Draper Aden Associates Blacksburg•Richmond,Virginia Engineering• Surveying• Environmental Services 8090 Villa Park Drive Richmond,Virginia 23228 804/264-2228 Fax: 804/264-8773 MEMORANDUM TO: Ms. Yadira Amarante, Planner FROM: Christopher M. Shust, Project Manager DATE: April 26, 2000 SUBJECT: North Fork District#2,Building#1• &#2 DAA Project# R99130-21 As was discussed during our phone conversation yesterday, The Planning Department will not be able to make a recommendation for approval of the Preliminary Site Development Plans at the May 2nd Meeting. As a result of this, we would like to request that the Planning Commission defer reviewing and voting on the plans until the May 16th meeting. As we discussed, there are two reasons for the deferral request. The first reason originates from the Department of Zoning submitting a set of review comments to your office on the day that your staff report was due to the Planning Commission, thereby not allowing Draper Aden Associates time to respond to the comments and resolve any issues. The other reason for the request originates from the Department of Engineering not receiving the waiver requests from the Planning Department in sufficient time to allow for their review and recommendation. As we had conveyed during our conversation, we are striving to meet a June 30e1 deadline for final site development plan approval and understand that the Planning Department will make every effort to assist us in keeping on schedule toward this deadline. Please feel free to give our office a call if you should have any questions or comments. We look forward to working with you to complete the review process for this project. 1H:\projects\R99\R991301R9913n-20L1cnrresp\crosyatleferr l.doc "WE EXIST TO HELP'OUR CLIENTS SUCCEED" Yadira Q.Amarante, Planner County of Albemarle Department of Planning &Community Development 401 McIntire Road County of Albemarle Charlottesville,VA 22902 Department of Planning & Phone: (804) 296-5823 ext. 3297 Fax: (804) 972-4012 Community Development Email yamarant@albemarle.org Fax To: C fr),-5 h ) From: Yadira Amarante Fax: S"o4 . 2 lo4 6 773 Pages: Phone: 20a. A,4.22Z6 Date: zi (PIOD Re: kb( ) CC: o Urgent 0 For Review 0 Please Comment 0 Please Reply 0 Please Recycle af‘ 5 - ( 40(-41e0 Cain mer4-s Cr I S'1--6- -Oa() 0,eprblin,t ttp Knob() . Ca ;ç Vey harm amy ashons V.A. f4:airi* o_. z 11111 COUNTY OF ALBEMARLE Department of Planning&Community Development MEMORANDUM ' TO: Chris Shust FROM: Yadira Amarante,Planner DATE: April 26,2000 , RE: SDP 00-024 North Fork Research Park,District#2,Buildings#1 &#2 Preliminary Site Plan (Revised March 30, 2000) Final approval from the Department of Planning and Community Development will be subject to the following conditions: (the following conditions are those that have been identified at this time. Additional conditions may be added or eliminated based on further review).Each comment is preceded by the applicable reference to the Zoning Ordinance. 1. [4.12.6.2] Parking areas shall be designed to facilitate unimpeded flow of on-site traffic in circulation patterns readily recognizable and predictable to motorists and pedestrians.Parking areas shall be arranged in a fashion to encourage pedestrian access to buildings and to minimize internal automotive movement. • Provide a clearly marked pedestrian walkway across the parking lot between the two buildings. The sidewalks shown, (along the southern parking lot travelway and then to building #2), make no sense for this particular development—please remove them.You can accomplish pedestrian access across the parking lot from building #1 to building#2 with striping.This would not necessitate removal of any parking spaces. • Please keep in mind that pedestrian access should be convenient and easily identifiable. 2. [32.3.8]No change,revision or erasure shall be made on any preliminary or final site plan nor on any accompanying data sheet unless authorization for such change is granted in writing by the agent, except when such change has been required by the site review committee or the commission. Any site plan may be revised, provided that a request for such revision shall be submitted and processed in the same manner as the original site plan. The foregoing notwithstanding, the agent may approve administratively, without submission to the site review committee or the commission,minor changes to an approved site plan in any case in which he shall determine that the site plan,as amended, is in compliance with the terms of all applicable law; is substantially in compliance with the approved site plan together with all conditions imposed by the commission or agent and will have no additional adverse impact on adjacent properties or public facilities. • This site plan shows changes to the PRA parking lot. These changes constitute an amendment to the original PRA site plan and must be submitted as such. 1 3 [32.5.6(a)] Owner, zoning,tax map and parcel number and present use of adjacent parcels • Ownership has changed on some of the properties; some parcel boundaries have changed. • Please include present use of adjacent parcels. 4 [32.5.6(a)] Minimum setback lines • Clearly distinguish,with labels,those setbacks which are building setbacks from those which are parking setbacks from those that are buffer zones.These are three(3)different things and should be labeled as such; all these areas continue to be shown as "buffer zone"on the plan. 5. [Policy]Please indicate the deed book and page reference for all existing utility easements located on the property. • [32.7.9] Approval of a landscape plan showing the proposed landscaping. Please contact me at your earliest convenience if you have questions or require additional information. 2 i.OF A a . atAth t RECEIVED In COUNTY OF ALBEMARLE APR 2 5 2000 Department of Building Code and Zoning Services PLANNING AND401 McIntire Road,Room 227 COMMUNITY DEVELOPMENTCharlottesville,Virginia 22902-4596 FAX(804)972-4126 TELEPHONE(804)296-5832 TTD(804)972-4012 MEMORANDUM TO: Yadira Amarante, Planner FROM: John Shepherd, Zoning Manager DATE: April 25, 2000 RE: SDP-00-24 North Fork Research Park, District#2, Office Buildings #1 & #2 Preliminary Plan Dated March 6, 2000 Revised March 30, 2000 The Albemarle County Department of Building Code and Zoning Services will approve the preliminary plan for zoning compliance when the following items have been satisfactorily addressed. The Building Official may provide separate comments. [Each comment is preceded by the applicable reference, which is to the Zoning Ordinance unless otherwise specified.] 1. [4.2, 4.2.3.2] Show the limits of the areas of slope that are 25% or more. Please be 6/ aware that earth disturbing activity within these areas will require a waiver from the Planning Commission. 2. [4.12.6.5 c] Curvilinear parking requires the approval of the Planning Commission. T3. [4.12.7.4 b] Loading spaces for offices are required on the basis of 1 space per 8,000 square feet of net office space. Building #1 requires 7 rather than 6 spaces based on 56,000 / 8,000 = 7. The parking statistics must be revised accordingly. Be aware the Planning Commission may reduce the required number of loading spaces based on the criteria contained in 4.12.7.6. 4. [ZMA 95-04] Show the buffer and Open Space as it was shown on Parcel B-8 on the Application Plan. T va1-of.the, -Plariffing-GemraissienT LrPf se.,mare� . Final approval from the Department of Building Code and Zoning Services will be subject to the following conditions: (The following conditions are those that have been identified at this time. Additional conditions may be added or eliminated based on further review.) UREF Dist. #2 Bldgs # 1 & 2 April 25, 2000 Page 2 1. [32.5.6 b] I count 436 parking spaces serving Building #1 and 180 spaces serving Building #2. Please review these figures and correct the number of parking spaces provided in the parking statistics and in the total buildout statistics accordingly. 2. [32.5.6 a] Note the tax map, parcel number and zoning on the parcels adjacent to the site. 3. [32.5.6 n] Show the location of all outdoor lighting on the plan. 4. [32.6.6 j] Provide a description and photograph or diagram and show the location of each type of outdoor luminaire that emits 3,000 or more initial lumens. Please be aware that installation of such luminaires in the future that are not shown on this plan shall require an amendment to this plan. 5. [32.6.6 j & 4.17.4 b] Include a photometric plan on the site plan demonstrating that parking area luminaires are in compliance with 4.17.4 b. 6. [ZMA 95-04] Proffer 3.1. Based on the requirement that construction could not exceed 500,000 sf in the initial year and shall not exceed 200,000 sf plus undeveloped square footage, a tally of the square footage that has been constructed up to now has been provided. Prior to final approval, we will discuss the formatting of this information. Recommendations for revisions may follow. Please contact me if you have questions or require additional information. APR. -07' 00 (FRI) 12: 40 VDOT C"'", TEL: 80e ""3 3759 P. 001 VIRGINIA DEPARTMENT OF TRANSPORTATION Charlottesville Residency 701 VDOT Way Charlottesville, VA 22911 Telephone FAX (804) 293-0011 (804) 979-3759 Date: April 7, 2000 From: J.H.Kesterson To: Steve Snell Phone: 293-0011 ext. 17 Dept of Engineering J FAX: (804) 979-3759 COMMENTS: SDP-00-024 North Fork Research Park, Phase 2 Buildings 1 & 2 Preliminary Plan, Rte. 29 The above referenced plan with revisions dated March 30, 2000 appears to have addressed our preliminary comments. However drainage comments will be required for review prior to final approval and the sight distance will need to be established prior to acceptance of Lewis and Clark Drive into the state system. Albemarle County Development Departments SDP-2000-024 SPIN Submission and Comments North Fork District#2, Bldg#1 & #2 Prelim SDP Engineering prelim site plan revision 2 reviewer received reviewed decision Steven Snell 4/6/00 4/17/00 approved The revised preliminary site plan for UREF North Fork Business Park, Building 1 and 2, received on 6 April 2000 has been reviewed The Engineering Department recommends approval of the preliminary site plan at this time. The following items must be submitted with the final site plan for review by the Engineering Department. a.An erosion control plan, narrative, computations, application and fee [18-32.7.4.3, 17-203] b.A stormwater management/BMP plan, computations, application and fee. Computations must include water quality, and detention routings for the 2yr and 10yr storms. [17-303,17-304] c. A completed stormwater management facilities maintenance agreement and fee, unless already completed. [17-304] d. Drainage computations. [18-32.7 4, Policy] A more thorough review of the E&SC plan and stormwater management plan will be conducted on the final site plan. Please contact me if you have questions or require additional information. 4/18/00 10:58AM Page 1 of 1 �f Yadira Amarante From: Pete Gorham [pgorham@acsanet.com] Sent: Monday, April 17, 2000 5:03 PM To: Yadira Amarante Subject: North Fork Research Park Phase 2 Buildings 1 & 2 SDP-00-024 Yadira, The Service Authority hereby grants preliminary approval to the site plan for the North Fork Research Park Phase 2 Buildings 1 &2. Tentative approval will not be granted until the following items have been satisfactorily addressed: (1) Approval of final water and sewer construction plans. This is a separate submittal (3 sets)to the Service Authority for review (2). Completion of the dedication of the water and sewer facilities in the North Fork Research Park Phase 1 Infrastructure plan. (3). Provide sanitary sewer and water line easements to the adjacent property Let us know if you have any questions. Thanks. -Pete Albemarle County Development Departments SDP-2000-024 SPIN Submission and Comments North Fork District#2, Bldg#1 & #2 Prelim SDP Fire/Rescue Revised Plan revision 2 reviewer received reviewed decision Bruce Crow 4/12/00 4/12/00 approved with conditions The listed comment can be addressed on the fial plan Add fire lane sign and marking to the center island located on the west side center of building 1 Add additional fire lane signs and markings along the travelway that runs parallel with the east side wall of building 2 Include a note on the plan that the three story building 1 will have a sprinkler system and standpipe system. 4/26/00 11 49 AM Page 1 of 1 04/25/00 07:53 FAX 804 264 8773 DRAPER ADEN ASSOCIATES, al ow. tl-,, / I 4 ITTAL 1 -ter Sri r�. DATE: -/ J : 9 ' 00 . Draper Aden Associates 5090 Villa ParkDrive TO: I?r SA t M, art 'C3E. . Richmond,Virginia 23228 804J264-2225 IT r COMPANY: A Fax: 804/2645773 ; FAX NO: 972- P 4O/ z Y u . F.ROM:_C244124 S A,r--._ . Blacksburg Office: (Richmond.Office) - - 2206 South Main Street Blacksburg, Virginia 24060 1 No. OF PAGES 540/552-0444 " INCLUDING COVER SHEET Fax: 540/552-0291 .- .'z COMId TENTS: 1-2 Comprehensive 45 z [R ell l e 1Ti ..szee, Engineering tl Services • Water and Wastewater 7A 0`.14: TE:ss4S' twi2, a M ec -,..i: { - .� -., 4 Solid Waste Management and Planning :; 7 ,' • Environmental Services - 'l i-�r • Surveying :, • Industrials Commercial & Residential Land -' Development - ; Engineering r. ._ .. . .._. id =4k . • Gemtechmical and ed Construction Services £= - If • Telecommunications k,; Engineering "WE EXIST TO HELP OUR CLIENTS SUCCEED" } . � ' .. �__� / u\ - ^ . ^ ' . . ' ' / . . \ � - , `~-� . \ . / . � ` _ [ '_^ ' / ` �� . � ` .. . .� ' . . . . ) ' / ` ,` . �-__' � � . .,� ' . , . . . '. . ' ^` ` ` . / . �� . , ' . \ /' `�_`. .- -_ ' , , ' . . Y� � ~ . \ , -- `.� COUNTY OF ALBEMARLE Department of Planning&Community Development 401 McIntire Road Charlottesville,VA 22901-4596 askve Snell) TO: - , et- FROM: ;e SLV1 - cShP hei-c1 Date: \5 loo pihoAnn - 4c_s JOB NO/FILE NAME 5-pp OD•c,24 : hAlAir1 or'lc tech PO k T.),4,AC,c-1-41-2) 8ld s.*I # 2 We are sending you the following items, Erktached, or ❑Under separateep cover: El Copy of letter Prints L�'Plans ❑ Plats ❑ Specifications ❑ Other COPIES DATE DESCRIPTION 313010O v I ec y Pi% � Con uMe i4-s f 2�e5 e tv ('fir,s S S(?C? £eu Jv►2 F-s These are transmitted as checked below: �� ElFor approval ❑ As requested [ ] For review and comment ❑ Approved as submitted ❑ For your use ❑ Resubmit copies for approval ❑ Approved as noted ❑ Return corrected prints ❑ Submit copies for distribution ❑ Returned for corrections ❑ Other Remarks: 2.SP (P tJ; 'OC S �P. 2,:.1); l',COncr 'x *s 61 N231 co. p\e_ase VeAke ocA CoctrY1e r } and `sfArT1 me . Liin \op Signature: 4/aoL1 `C Draper Aden Associates LETTER OF TRANSMITTAL Blacksburg•Richmond,Virginia DATE JOB NO. Engineering*Surveying•Environmental Services 4/1/00 R99130-20 8090 Villa Park Drive ATTENTION Richmond,Virginia 23228 Yadira Amarante RE: Phone(804)264-2228 North Fork Research Park Fax(804)264-8773 SDP 00-024 TO County of Albemarle Department of Planning&Community Development 401 McIntire Road,Room 218 Charlottesville,VA 22902-4596 WE ARE SENDING YOU X Attached Under separate cover via the following items: Shop Drawings Prints Plans Samples Specifications Copy of Letter Change Order COPIES DATE NO. DESCRIPTION 7 Revised Preliminary Site Development Plans 1 Half Sized Preliminary Site Development Plan 1 Critical Slope Disturbance Waiver Request 1 Curvilinear Parking Waiver Request REGeAVE4 1 Service Space Waiver Request OR o 3 2000 1 Memo to Bruce Stouffer RE. VDOT 1 RESPOI�ISG 'To cs�M TS A' r- P� ev ®PMENT COMMUM THESE ARE TRANSMITTED as checked below. For approval Approved as submitted Resubmit copies for approval For your use Approved as noted Submit copies for distribution X As requested Returned for corrections Return corrected prints For review and comment FOR BIDS DUE 19 PRINTS RETURNED AFTER LOAN TO US REMARKS COPY TO FILE SIGNED: Christopher M Shust, Project Manager 47,14, .,"•4TiSeP'.'7';7tf� `'s�'7'"5as,:2x<y '.I7 t's entR:;>PI'VitT<. T�1t 31 S7ta+t7 C:a t's±S f±1•• ) .1J; {GL<`,d?<S:,fl.Cti❑7<ry %);‘ March 29, 2000 Mr. Bruce B. Stouffer Director of Administration and Research Park Development 465 Crestwood Drive Charlottesville,VA 22903 RE: North Fork Research Park Phase I Infrastructure Dear Bruce: VDOT and the Albemarle County Service Authority both indicated that the dedication of the Phase I infrastructure has not been completed for North Fork. The Service Authority is making the completion of the dedication a requirement for approval of the two sets of plans that we have submitted (SDP 00-024, 025). If the dedication is not completed, it could impact the internal deadlines that we have set for obtaining site plan approval. VDOT has also indicated that there is a sight distance problem that has been caused by the landscaping of the median. Bob Ball indicated that he and Jim Kesterson would gladly meet us on site to identify the area of concern and requirements for modification. I can arrange the meeting if you let me know your availability. Please let me know if you have any questions or comments regarding this information. Sincerely, DRAPER ADEN ASSOCIATES, INC AP,„4"-- Christopher M. Shust Project Manager H:\projects\R99\R9913 0\R9913 0-20\corresp\crosbs32900.doc Blacksburg,Virginia♦Richmond,Virginia♦Raleigh/Durham,North Carolina I \M � cL C ._._ 1l i o c9 g. 1 C c , __,_ -T_�-- - __ --t �.:—� _ _ t .F_-_. -,-----i -- 1 III 1 1 *-- __H_____ \------- Ply (r7-'1\ '?%\-(2, ----5,--p A ' I 'I /717* C7 U I � - ' - . . . , � � ' � ' � . ` - - -_ - ' ' . _ _ -- -` ~ ' ` ` ~ . ' � - . ` . - � - . -'�` ` ` * ^ ` . ) '''' ` �_ � ' . ' _ . _ _. � . _ _ _ � ` . ' . `. ' ^ . ` ` . ` . ` ' ' ` . . . . '`` - ` ` ' `^ .. ' � ' ' ^ .� i'' ' ' ` . . ' . . ^ ' � -� . . � / . ` ' ' , ' ' ^ \�� ` /.� ___�__,_�_ _ . . , \. . , _. � ` -�-- -'- ' ` \ ' \ , - , � ` - _ �v � ' 'm~ r,i • AOFA 14111.4 1072* 5E—TO iv? COUNTY OF ALBEMARLE L�M d Department of Planning&Community Development 401 McIntire Road,Room 218 Charlottesville,Virginia 22902-4596 (804)296-5823 Ext.3297 Fax(804)972-4012 March 21,2000 Chris Shust Draper Aden Associates 8090 Villa Park Drive Richmond,VA 23228 Re: SDP 00-024 North Fork Research Park,District#2,Buildings#1 &#2 Preliminary Site Plan Dear Mr. Shust: The Site Review Committee has reviewed the development proposal referenced above. Preliminary comments from the following agencies,as applicable,are attached. Albemarle County Department of Planning&Community Development Albemarle County Department of Engineering and Public Works Virginia Department of Transportation Albemarle County Department of Zoning Albemarle County Department of Inspections Albemarle County Fire/Rescue Division Albemarle County E911 Mapping Albemarle County Service Authority Thomas Jefferson Health District Comments reflect information available at the time the development proposal was reviewed,and should not be considered fmal. However,the Site Review Committee has attempted to identify all issues pertaining to the approval of the proposed project. Please make the revisions which have been identified as necessary for preliminary approval by the Site Review Committee.If you choose not to make the requested revisions,please submit in writing justification for not incorporating such revisions. Submit seven full size copies and one 11"x17"copy to the Department of Planning and Community Development. Responses to the attached comments of the Site Review Committee must be submitted by April 3,2000. Failure to submit this information by this date will result in suspension of the review schedule. Please contact me at your earliest convenience if you have questions or require additional information. Si er 47 adira Amarante, Planner Attachments: Site Review Comments Copy: SDP 00-024 • • ' ' 4'OR ALgt, rigr COUNTY OF ALBEMARLE Department of Planning&Community Development MEMORANDUM • TO: Chris Shust FROM: Yadira Amarante, Planner DATE: March 20,2000 RE: SDP 00-024 North Fork Research Park, District#2,Buildings#1 &#2 Preliminary Site Plan The Albemarle County Department of Planning and Community Development will approve the preliminary plan referenced above when the following items have been satisfactorily addressed: [Each comment is preceded by the applicable reference.] ram_ ,g 1. [4.12:6:2],Parking areas shall be designed to facilitate unimpeded flow of on-site traffic in circulation patterns readily cognizable and predictable to motorists and pedestrians. Parking areas shall be arranged in a fashion to encourage pedestrian access to buildings and to minimize internal automotive movement. • Provide a clearly marked pedestrian walkway across the parking lot between the two buildings.-3 1 p ''QI'WWd • Show inter-parcel pedestrian connections or 1W ; aa� s O\\C float-) w, )7 fcJogS ►L9 LA s-1-0E w-xciz-ii-AS" 11%k uALoi\JG MAW TPA VEL [ 66-S ll.) Lieu OF 12-co—Ye �i U2in E IpA e lG 1 N G .A-e.. C f2 Er6e _ G i ✓� 2 [26:4':1]-Ploor�area ratio-Maximum total oor area permissible for individual lots shall not exceed 0.70 times the land area of the lot. • The Floor Area Ratio calculations on the cover sheet appear to be.based on_th_e building footprint rather than the gross floor area. Please correct. FAO. CALCtAI L.A110 AO-E—BECN1--RE Sed ✓R 3. [26.10.3] Buffer zone adjacent to residential and rural areas districts: No construction activity including grading or clearing of vegetation shall occur closer than thirty(30)feet to any residential or rural areas district. Screening shall be provided as required in section 32.7.9 7 •/• Please show and label method of proposed screening. �(�1d S i�Eu_ LR ivl- Y_Z_N 6` 13U FF6L 0 o On sheet CS please change the `buffer text' adjacent to the residential areas to state "30' buffer—no grading or -cq clearing of vegetation allowed without Planning Commission approval." [KjO`i E ✓• On sheet C4, adjacent to the residential area, please revise the limits of clearing to 30' away from the parcel boundary. NvDD� 1 �y32.3.8 _No change, revision or erasure shall be made on any _,[ ] g , preliminary or final site plan nor on any accompanying data sheet unless authorization for such change is granted in writing by the agent, except when such change has been required by the site review committee or the commission. Any site plan may be revised, provided that a request for such revision shall be submitted and processed in the same manner as the original site plan. The foregoing notwithstanding, the agent may approve administratively, without submission to the site review committee or the commission, minor changes to an approved site plan in any case in which he shall determine that the - • ;site plan, as amended, is ii_ 4ripliance with the terms of all applicable is substantially in compliance with the approved site plan together with all conditions imposed by the commission or agent and will have no additional adverse impact on adjacent properties or public facilities. • This site plan shows changes to the PRA parking lot.These changes constitute an amendment to the original PRA site plan and must be submitted as_such. [A MTrto `SITE P LA rJ AM 6J fYi%AC*JT_tom P IRA S H -1 P E S U i3r�'►c_�G 4 [32:5.3] All-waiver,variation and substitution requests in accordance with section 32.3.10 shall be submitted with the preliminary site plan and clearly state the specific items being requested for waiver, variation or substitution. • You will need to request a waiver for curvilinear parking [4.12.6.5(c)]. LJ A t V_ Q,EO)e— Wt3M-i t �• You will need to request a waiver for disturbing critical slopes [4.12.6.2]. kaiktuee. R.FO ST 5�5M.t`C>- 15 [32.5.6(a)] Tax map and parcel number. • The original properties have been combined, by plat, into one parcel-Parcel 6A. -16. [32.5.6(a)] Zoning • The property is also within the AIA-Airport Impact Area. WO i .ADDED -TO Cbvre2- SIDE 1`� ✓�7__[32.5.6(a)]9wner, zoning, tax map and parcel number and present use of adjacent parcels �L, • Ownership has changed on some of the properties; some parcel boundaries have changed. '�'The Please include present yse..of adjacent parcels. �1--I;t-S 1.tt s=-D�.M�,i 1-OtJ I3D Cites Si-VALL Be- PC-FtrC r-(-r) 0 Fr0A--S.)3M( cr ';'8. [32.5.6(a)] Minimum setback-lines • Please show setback lines from PRA property and from Lewis& Clark Drive. ESE PCiEs SOv-W • Clearly distinguish,with labels,those setbacks which are building setbacks from those which are parking setbacks or buffer zones. 1-S Eb f✓9. [32.5.6(a)] Boundary dimensions. • Boundary information is missing along Lewis&Clark Drive. DUBOA�'`l' I -()(2-M+4Tl 14A ?)E6) : -00a 10. [32:5-6(b)]"Proposed"uses arid maximum acreage occupied by each use. More specifically, in the"Lot Coverage" table please include: ✓• Proposed use for each building, i.e. "General Office". ids i- CP -h Co t SC-tEE►�' ✓'• Percentage of site covered for each feature for each building, i.e. Lot Coverage: (Lease Area) Building No. 1 Building 23,333 s.f. (.13%) kjpT-ES �QC;;C) Parking& Driveways 89,275 s.f. (.52%) 6'Cn t✓2._ SttK11 r'j 11. [32.5.6(b)] Percent and acreage of open space. ✓• As shown on the application plan for ZMA 95-04, please label and provide the acreage for the open space lying to the south of the property. LAIS"C,l F,J'LD_ g /l2 [32.5.6(c)] If phasing is planned, phase lines and proposed timing of development. ✓• Phasing text and lines, on sheets C4, C5, and C6, are in conflict. '(� S_ktJCA__ V. Please include the proposed timing of each phase. [T �j SGt E DUB E % �?'� _ �V sEtT /V13. [32.5.6(d)] Areas of the site where existing slopes are twenty-five (25) percent or greater. • There are areas of critical slop s)throughout the site. Please shade and label these areas. /14 [32:5 6(i)fExisting and proposed`stieets;access easements and travelways, together with street names, state route 2 numbers,right-of-way lii; :nd widths,centerline radii, and pavemei dths. • ore s ecifically,please include r-o-w and pavement widths. nr' ,1, `s A Ca sk. RO�J 5tt°'^r u ►gyp P ) k.) NG to-r- (20 s 132 7.2.8]-Provision shall be made for sidewalks and pedestrianwalkways which will enable pedestrians to walk ----- safely and conveniently between buildings on the site and from the site to adjacent property. To this end: • Please better show and label sidewalks along Lewis &Clark_D- rive-and-show how you are planning to get pedestrians from that sidewalk into the site. pi'I vJA'_t Stt_ w v • Show inter-parcel pedestrian connections - Sl 1.C�G%vi L'.k �t s -�w a 116. [Policy] Please reference the benchmarks used for surveys on sheet C3. (BE-r.1C,kNti,a�?{�s q EL( C.p (17 1,7[Policy_]_P-lease indicate the deed book and page reference_for_all_existingutility-easements located on the property /� tfi5/iG of x�-- --A-gSKA:�i Bpi Nc. i ci:t '� 18. [ZMA 95=04]-Proffers-dated 3/2-U96"Proffer 8.2,Page 11: Hazardous Materials. PL • Please verify that no hazardous materials, including medical wastes shall be disposed within the Project. -AD AD GO E S E Final tentative approval from the Department of Planning and Community Development will be subject to the following conditions: (The following conditions are those that have been identified at this time.Additional conditions may be added or eliminated based on further review) -11 '[327-9]AApproval of a landscape plan showing the proposed landscaping. 2. [4.12.6.5(c)] Planning Commission approval of a waiver for curvilinear parking. 3. [4.12.6.2] Planning Commission approval of a waiver for disturbing critical slopes. Please contact me at your earliest convenience if you have questions or require additional information. 3 • • Albemarle County Development Departments SDP-2000-024 SPIN Submission and Comments North Fork District#2, Bldg#1 & #2 Prelim SDP Engineering prelim site plan revision 1 reviewer received reviewed decision Steven Snell 3/9/00 3/20/00 requested changes The preliminary site plan for UREF North Fork Business Park, Building 1 and 2, received on 9 March 2000 has been reviewed. The Engineering Department will recommend approval when the following items have been satisfactorily addressed. 1 Several grade lines terminate at the top (northern) edge_of Sheet C-6 Please show the total extent of all grading. [18-32.5.6d] A b%tCA. s�(7).w 2. The area enclosing building#2-is labeled"PH-ASE 1" along its eastern,boundary and labeled"PHASE 2" along its southern boundary (sh. C-6). Please clarify [Policy] Co �2�GD "pASt✓ 2 ' � ` 3 Please show any retaining walls that may exist. Retaining walls 5-feet or taller will require and' Engineers seal and signature. [Policy] ° Lip ( E;TI"�:11.;f 'G,M.} "T, I 4 Please show proposed radii for the entrances [18=32:5:61] 5 Please indicate the available sight distance for entrances and left turn lanes. [Policy]-7,5.l`Cigt: - 6 Provide plan revisions required by VDOT. [Policy] Lt3o7"'` j The followingitems must be submitfed`witti he final site plan for review by the Engineering Department. a. An erosion control plan, narrative, computations, application and fee. [18-32.7 4 3, 17-203] b. A stormwater management/BMP plan, computations, application and fee. Computations must include water quality, and detention routings for the 2yr and 10yr storms. [17-303,17-304] c. A completed stormwater management facilities maintenance agreement and fee, unless already completed. [17-304] d. Drainage computations. [18-32.7 4, Policy] Please contact me if you have questions or require additional information 3/21/00 02:05 PM Page 1 of 1 • O A 1411 COUNTY OF ALBEMARLE Department of Engineering&Public Works MEMORANDUM TO: Yadira Amarante, Planner FROM: Steven Snell and Mark Graham, Engineering DATE: 23 March 2000 RE: North Fork District#2, Building 1 & 2, preliminary site plan These comments are more of an advisory than a requirement for the preliminary plan, but should be addressed on the final plan. 1. The proposed sediment basin only works for the initial clearing phase. Once they initiate..SEk'645A the proposed grading, the diversion dikes will be filled and perimeter control has been R.F N octctvr2 lost. Also, the grading shown on sheet c-6 indicates about 2/3 of the sediment basin area=tE ? will be filled to construct the entrance road for this site. shown grading for existing PRA/AaDJusT, 6J AS El LL;000U'' parking lot indicates some additional areas will drain to sediment basin. This means ___ <_ _ sediment basin drainage area should account for this area. 2. 2:1 slopes (horizontal:vertical) are not acceptable as mowed areas. Per the Virginia rK.10-r-E„A-4:pa Erosion and Sediment Control Handbook, mowed slopes must be 3:1 or flatter. If the =G t slope is not to be mowed, the applicant will be required to indicate the areas to receive L• ' groundcovers instead of grass as part of the Erosion and Sediment Control Plan. 3. The diversion dike"DD"shown on the northern perimeter should actually be a diversion p`,� toQ- "DV" . This is not critical because the shown diversion doesn't work during [1aE--t-Aro.iC—o construction. The grading on sheet C-6 clearly shows this area will be regraded, preventing this diversion from ever working. 4. There is no provision for control sediment with the proposed storm sewer. The storm (j l DEO sewer is not shown on the erosion control plan and there is no mention of providing inlet T� ►�! ' protection. 5. As this road is now in the State highway system, it is doubtful they can place inlet protection across the existing inlets along Lewis and Clark Drive as proposed. Sediment, control must be provided on site. 6. The construction entrance must be 12' x 70' paved wash rack with water supplied from a C- t h tL 1"meter and 1" tap connected to a 1 V2" hose with a 1"nozzle. Construction entrance M-EATS",. '� must also have a sediment trap for the washed sediment.en, ,�oD 1�� L � • W Gc+N l e-ff.Ib,1 7. The proposed storm sewer in the northwest corner of this srtt snot dischaige into an eA existing drainage way. They will need to provide channel calculations demonstrating the 1 adequacy of the proposed channel with respect to both capacity and velocity s= 8 The drainage area for the topsoil stockpile exceeds that allowed for use of silt fence. S-r �r�r They will need to provide other means of sediment control, possibly a sediment trap or' basin. 9. The engineer will need to demonstrate the adequacy of the channel for the storm sewer A5 discharges with respect to both flow and erosive velocities where this water enters the Vr`_s?`C '=�'� N existing stream. t F, r�ES�, 40. The storm set at the northeast corner of Building 1 't simply discharge onto the • ground next a_._—ewis and Clark Drive. This is a curb cuiu gutter street with a sidewalk between the discharge and the street. The storm sewer must connect to the existing storm sewer. jr-ei.—Lt EL1l0-t=.1 Sk-l-bv1,/ A 5 2EQvES • L Please contact me if you have questions or require additional information. Copy: file File:memo North Fork Town Center • 'u.i 151`�ti Ti i?) COMMONWEALTH of VIRGINIA DEPARTMENT OF TRANSPORTATION 701 VDOT WAY COMMISSIONER CHARLOTTESVILLE, 22911 March 16,2000 A. G.TUCKER RESIDENT ENGINEER Site Review Meeting March 23, 2000 Mr. Glenn E. Brooks Dept. of Engineering 401 McIntire Road Charlottesville, VA, 22902 Dear Mr. Brooks: The following are our comments: :.TaTP-00-024 North Fork Research Par Phase 2 Buildin s 1 & 2 Prelimina n, Route 29 i• This site plan should include a running total of previously approved and currently proposed-building_areaslor,Nortb._Fork.Park. ,/• Plan should �, include note at entrance location stating that traffic signal, when warranted by VDOT, will be installed b specifications. Y the developer to VDOT • The median area will require q grading to provide sight distance for left turns. A minimum 450' is required for left turn,however should the south side of the intersection develop, the entrance will require 525'. The 450' sight line will need to be established prior to_Lewis and Clark Drive being accepted into_the State System. y O AReco .5 .r yC,- i_ mmend the proposed internal right turn lane be extended full width to the parking area. This will allow for additional storage when the site is fully developed and traffic signal is installed. • � :A S t2EC l'�C S�`t P Drainage computationsshould_be-submi.'-- d=for= kkj) t t� � 2,1.(k S TRANSPORTATION FOR THE 21ST CENTURY IT 111111111 8==476.w.;;% RECEIVED f N1P MAR 2 0 2000 COUNTY OF ALBEMARLE Department of Building Code and Zoning Services PLANNING AND 401 McIntire Road, Room 227 COMMUNITY DEVELOPMENT Charlottesville,Virginia 22902-4596 FAX(804)972-4126 TELEPHONE(804)296-5832 TTD(804)972-4012 MEMORANDUM TO: Yadira Amarante, Planner FROM: John Shepherd, Zoning Manager . DATE: March 20, 2000 RE: SDP-00-24 North Fork Research Park, District#2, Office Buildings #1 & #2 Preliminary Plan Dated March 6, 2000 The Albemarle County Department of Building Code and Zoning Services will approve the preliminary plan for zoning compliance when the following items have been satisfactorily addressed. The Building Official may provide separate comments. [Each comment is preceded by the applicable reference, which is to the Zoning Ordinance unless otherwise specified.] A. [4.2, 4.2.3.2] Show the limits of the areas of slope that are 25% or more. Please be aware that earth disturbipg_a.ctivity_within-these-areas-may-require-a-waiver from the Planning Commission. Gg>vi(C � S_ ,�CS . tv2 r2C—c�y�S� AA-c-R /. [4.12.6.5 c] Curvilinear parking requires t valof the Planning Commission. �► i vee i� U_E S"�_ 'TA CCt-F I - _ Old 3. [32.5.6 a] Note the tax_map.,_par_ceLnumber and zoning on the parcels adjacent to the site. TD (Z v tSC,®,'. d 74. [32.5.6 a] Add reference to ZMA 98-27 to the plan. �00 s TC) Cc"--� N� 5. [4 12.6.6.1] Parking for office use is based on 1 space per 200 square feet of net (80%) office floor area. The parking statistics for both buildings must be revised accordingly. Building #1- 70,000 x 80% = 56,000 / 200 = 280.� Building #2- 40,000 x 80% = 32,000 / 200 = 160 � ‘S - 6. [4.12.7.4] Show the loading spaces dimension-e_d_at_a_minirau n of 12' x 25'. seacE5 iZEVi 7. [4.12.7.4 b] Loading spaces for offices are required on the basis of 1 space per 8,000 square feet of net office space. Building #1 requires 7 rather than 6 spaces UREF Dist. #2 Bldg, 1 & 2 March 20 Page 2 based on 56,000 / 8,000 = 7. The parking statistics must be revised accordingly.- , Be aware the Planning Commission may reduce the required number of loading spaces based on the criteria contained in 4.12.7.6. S x A l J iZeCl-�E sj ,T-.4Ct�iv ca /[32.5.6 b] I count 443 parking spaces serving Building #1nd 180 spaces serving Building #2. Please review these figures and correct the parking provided and the total buildout statistics accordingly. C;cw�c S R; ;vl --di"Bcp-bO tt\-- X[26.10.1] Please show a 10' building and 10' parking setback from Lewis and Clark Drive. 10.[ZMA 95-04] Show the buffer and Open Space as it was shown on Parcel B-8 on the Application Plan. /11.[ZMA 95-04] Proffer 3.1. In order to keep track of all the elements contained in 3.1, add the following elements to the total buildout schedule. • Include MicroAire and Motion Control. t=kvv/1`l dN-.COU P St • Identify the square footage constructed per year beginning on June 12,ak-VAg ti,:Cav , • Based on the requirement that construction could not exceed 500,000 sf in the initial year and shall not exceed 200,000 sf plus undeveloped square footage, begin to tally the square footage that could be constructed now. 2 12.[ZMA 95-04] Proffer 4.4 Note on the plan, No single user will require more than ' 125,000 gallons per day (average daily consumption) of potable water without obtaining County approval. t T ,, c-'P /13.[4.17.4] Note on the plan, "Each outdoor luminaire equipped with a lamp which emits 3,000 or more initial lumens shall be a full cutoff luminaire or a decorative luminaire with full cutoff optics." N `�Z A 9 1.[4.17.4.3] Note on the plan, "The spillover of lighting from parking area luminaires onto public roads and property in residential or rural areas zoning districts shall not exceed one-half('A) foot candle." 00��. 1-; P_7' Final approval from the Department of Building Code and Zoning Services will be subject to the following conditions: (The following conditions are those that have been identified at this time. Additional conditions may be added or eliminated based on further review.) 1. [32.5.6 n] Show the location of all outdoor lighting on the plan. UREF Dist. #2 Bldgs # 1 & 2 March 20 Page 2 2. [32.6.6 j] Provide a description and photograph or diagram and show the location of each type of outdoor luminaire that emits 3,000 or more initial lumens. Please be aware that installation of such luminaires in the future that are not shown on this plan shall require an amendment to this plan. 3. [32.6.6 j & 4.17.4 b] Include a photometric plan on the site plan demonstrating that parking area luminaires are in compliance with 4.17.4 b. Please contact me if you have questions or require additional information. Albemarle County Development Departments SDP-2000-024 SPIN Submission and Comments North Fork District#2, Bldg#1 & #2 Prelim SDP Building prelim site plan revision 1 reviewer received reviewed decision Jay Schlothauer 3/16/00 3/21/00 approved Based on plans dated March 6, 2000 No comments or conditions. • 3/22/00 11:59 AM Page 1 of 1 Albemarle County Development Departments SDP-2000-024 SPIN Submission and Comments North Fork District#2, Bldg#1 & #2 Prelim SDP Fire/Rescue prelim site plan revision 1 reviewer received reviewed decision Bruce Crow 3/16/00 3/21/00 approved with conditions Fire Lanes will be required. Fire lanes shall be designated by signs and pavement markings as required by the Fire Offical. (Albemarle County Fire Prevention Code, Section 6-204) Fire Lanes will be required at the Fire dept. connection location, the front Island and along the north side service entrance of building# 1. Fire lanes will be required along the front travelway of building#2 and on the northside at the fire hydrant and fire department connection location. 3P Building# 1 will be required to be equipped with a fire department standpipe system with fire hose connection located inside the interior stairwells on each floor for parking to be allowed in front of the building. (Albemarle County Zoning Ordinance, Section 18-32.7.6) The dumpster on the north end of building# 1 is within 15' of the building Relocate the trash receptacle. Trash receptacles shall be located a minimum of 15'from any property line or building. (Albemarle County Fire Prevention Code, Section 6-200, F-2103.3) 3/21/00 02:06 PM - Page 1 of 1 • • Albemarle County Development Departments SDP-2000-024 SPIN Submission and Comments North Fork District#2, Bldg#1 & #2 Prelim SDP E-911 Mapping [description and date] revision 1 reviewer received reviewed decision Damon Pettitt 3/13/00 3/13/00 approved No action by E-911 Addressing Staff is necessary for FINAL approval. 3/21/00 02:05 PM Page 1 of 1 ALBEMARLCOU \TYSERIOE AUTHORITY MEMO To. Yadira Q. Amarantee, Planner F R O Peter C. Gorham, Senior Civil Enginee; '` DATE: March 23, 2000 RI_: Site Plan Technical Review for: North Fork Research Par} Phase ,2 Buildinas 1 & 2 (TM 32. Parcel 6A) The below Checked items apply to this site. X 1. This site plan is within the Authority's jurisdictional area for: _X_ A. Water and sewer B. Water only C. Water only to existing structure D. Limited service X 2. A 1221 waterline is located onsite. 3 . Fire flow from nearest public hydrant, located distant from this site plan, is gpm ± at 20 psi residua.. ,_X_ 4. An 521 sewer line is located onsite. 5. An Industrial Waste Ordinance survey form must be completed. _X_ 6. No improvements or obstructions shall be placed within existing or future easements. 7. and plans are currently under review. 8. and plans have been received and approved. 9. No plans are required. X 10. Final water and sewer plans are required for our review and approval prior to granting tentative approval. 11. Final site plan may/may not be signed. 12. RWSA approval for water and/or sewer connections. Comments: Final annroval will not be granted until the water and sewer lines in the North Fork Research Park hav J een dedicated to and accepted by the Service Authority. Prov,ide sanitary sewer and water line easements to adjacent property. Backflow prevention devices required on domestic water services. The site plan does not show or incorrectly shows: meter locations waterline size waterline locations sewer line size sewer line locations expected wastewater flows easements expected water demands SDP-00.024 • Amendments to Site Review Committee Comments 3/23/00 At the northeast corner of Building 1 look at their proposed loading spaces and dumpster. First, the loading spaces don't work at all. Second,the loading spaces block access to the dumpster. Third, even if the dumpster is in a fence, they put it in the front yard along Lewis and Clark Drive. Fourth, the cover sheet indicates there are 6 spaces,but I count 4 spaces. r OF A RC1N COUNTY OF ALBEMARLE Department of Planning&Community Development 401 McIntire Road,Room 218 Charlottesville,Virginia 22902-4596 (804)296-5823 Ext.3297 Fax(804)972-4012 March 21,2000 Chris Shust Draper Aden Associates 8090 Villa Park Drive Richmond,VA 23228 Re: SDP 00-024 North Fork Research Park,District#2,Buildings#1 &#2 Preliminary Site Plan Dear Mr Shust: The Site Review Committee has reviewed the development proposal referenced above. Preliminary comments from the following agencies,as applicable,are attached. Albemarle County Department of Planning&Community Development Albemarle County Department of Engineering and Public Works Virginia Department of Transportation Albemarle County Department of Zoning Albemarle County Department of Inspections Albemarle County Fire/Rescue Division Albemarle County E911 Mapping Albemarle County Service Authority Thomas Jefferson Health District Comments reflect information available at the time the development proposal was reviewed,and should not be considered fmal. However,the Site Review Committee has attempted to identify all issues pertaining to the approval of the proposed project. Please make the revisions which have been identified as necessary for preliminary approval by the Site Review Committee. If you choose not to make the requested revisions,please submit in writing justification for not incorporating such revisions. Submit seven full size copies and one 11"x17"copy to the Department of Planning and Community Development. Responses to the attached comments of the Site Review Committee must be submitted by April 3,2000.Failure to submit this information by this date will result in suspension of the review schedule. Please contact me at your earliest convenience if you have questions or require additional information. S. er adira Amarante,Planner Attachments: Site Review Comments Copy: SDP 00-024 pE A u®�� COUNTY OF ALBEMARLE Department of Planning& Community Development MEMORANDUM TO: Chris Shust FROM: Yadira Amarante, Planner DATE: March 20, 2000 RE: SDP 00-024 North Fork Research Park, District#2, Buildings#1 &#2 Preliminary Site Plan The Albemarle County Department of Planning and Community Development will approve the preliminary plan referenced above when the following items have been satisfactorily addressed: [Each comment is preceded by the applicable reference.] 1. [4.12.6.2] Parking areas shall be designed to facilitate unimpeded flow of on-site traffic in circulation patterns readily recognizable and predictable to motorists and pedestrians. Parking areas shall be arranged in a fashion to encourage pedestrian access to buildings and to minimize internal automotive movement. • Provide a clearly marked pedestrian walkway across the parking lot between the two buildings. • Show inter-parcel pedestrian connections 2. [26.4..1] Floor area ratio.Maximum total floor area permissible for individual lots shall not exceed 0 70 times the land area of the lot. • The Floor Area Ratio calculations on the cover sheet appear to be based on the building footprint rather than the gross floor area. Please correct. 3 [26.10.3] Buffer zone adjacent to residential and rural areas districts: No construction activity including grading or clearing of vegetation shall occur closer than thirty(30)feet to any residential or rural areas district. Screening shall be provided as required in section 32.7.9 • Please show and label method of proposed screening. • On sheet C5 please change the `buffer text' adjacent to the residential areas to state "30' buffer—no grading or clearing of vegetation allowed without Planning Commission approval." • On sheet C4, adjacent to the residential area, please revise the limits of clearing to 30' away from the parcel boundary 3 1/L, [32.3.8]No change, revision or erasure shall be made on any preliminary or final site plan nor on any accompanying data sheet unless authorization for such change is granted in writing by the agent, except when such change has been required by the site review committee or the commission. Any site plan may be revised, provided that a request for such revision shall be submitted and processed in the same manner as the original site plan. The foregoing notwithstanding, the agent may approve administratively, without submission to the site review committee or the commission,minor changes to an approved site plan in any case in which he shall determine that the 1 site plan, as amended, is in coin , ice with the terms of all applicable law; .t__,Lbstantially in compliance with the approved site plan together with all conditions imposed by the commission or agent and will have no additional adverse impact on adjacent properties or public facilities. • This site plan shows changes to the PRA parking lot.These changes constitute an amendment to the original PRA site plan and must be submitted as such. 4. [32.5.3] All waiver,variation and substitution requests in accordance with section 32.3.10 shall be submitted with the preliminary site plan and clearly state the specific items being requested for waiver, variation or substitution. • You will need to request a waiver for curvilinear parking [4.12.6 5(c)]. • You will need to request a waiver for disturbing critical slopes [4.12.6.2] 5. [32.5.6(a)] Tax map and parcel number. • The original properties have been combined, by plat, into one parcel—Parcel 6A. 6. [32.5.6(a)] Zoning • The property is also within the AIA-Airport Impact Area. 7. [32.5.6(a)] Owner,zoning,tax map and parcel number and present use of adjacent parcels • Ownership has changed on some of the properties; some parcel boundaries have changed. • Please include present use of adjacent parcels. 8 [32.5 6(a)] Minimum setback lines • Please show setback lines from PRA property and from Lewis & Clark Drive. • Clearly distinguish,with labels,those setbacks which are building setbacks from those which are parking setbacks or buffer zones. 9. [32.5.6(a)] Boundary dimensions. • Boundary information is missing along Lewis & Clark Drive. 10. [32.5.6(b)] Proposed uses and maximum acreage occupied by each use. More specifically, in the"Lot Coverage" table please include. • Proposed use for each building, i.e. "General Office" • Percentage of site covered for each feature for each building, i.e. Lot Coverage: (Lease Area) Building No. 1 Building 23,333 s.f.`(.13%) Parking&Driveways 89,275 s.f. (.52%) 11. [32.5.6(b)] Percent and acreage of open space. • As shown on the application plan for ZMA 95-04, please label and provide the acreage for the open space lying to the south of the property 12. [32.5.6(c)] If phasing is planned, phase lines and proposed timing of development. • Phasing text and lines, on sheets C4, C5, and C6, are in conflict. • Please include the proposed timing of each phase. 13 [32.5.6(d)] Areas of the site where existing slopes are twenty-five (25) percent or greater. • There are areas of critical slopes throughout the site. Please shade and label these areas. 14 [32.5.6(i)] Existing and proposed streets, access easements and travelways,together with'street names, state route 2 numbers, right-of-way liner !widths, centerline radii, and pavement hs. • More specifically, please include r-o-w and pavement widths. 15. [32.7.2.8] Provision shall be made for sidewalks and pedestrian walkways which will enable pedestrians to walk safely and conveniently between buildings on the site and from the site to adjacent property To this end: • Please better show and label sidewalks along Lewis & Clark Drive and show how you are planning to get pedestrians from that sidewalk into the site. • Show inter-parcel pedestrian connections 16. [Policy] Please reference the benchmarks used for surveys on sheet C3. 17 [Policy] Please indicate the deed book and page reference for all existing utility easements located on the property. 18. [ZMA 95-04] Proffers dated 3/21/96 Proffer 8.2, Page 11: Hazardous Materials. • Please verify that no hazardous materials, including medical wastes shall be disposed within the Project. Final tentative approval from the Department of Planning and Community Development will be subject to the following conditions: (The following conditions are those that have been identified at this time. Additional conditions may be added or eliminated based on further review.) 1 [32.7 9] Approval of a landscape plan showing the proposed landscaping. 2. [4.12.6.5(c)] Planning Commission approval of a waiver for curvilinear parking. 3 [4.12.6.2] Planning Commission approval of a waiver for disturbing critical slopes. Please contact me at your earliest convenience if you have questions or require additional information. 3 Amendments to Site Review Committee Comments 3/23/00 At the northeast corner of Building 1 look at their proposed loading spaces and dumpster. First, the loading spaces don't work at all. Second, the loading spaces block access to the dumpster. Third, even if the dumpster is in a fence, they put it in the front yard along Lewis and Clark Drive. Fourth, the cover sheet indicates there are 6 spaces, but I count 4 spaces. • Albemarle County Development Departments SDP-2000-024 SPIN Submission and Comments North Fork District#2, Bldg#1 & #2 Prelim SDP Engineering prelim site plan revision 1 reviewer received reviewed decision Steven Snell 3/9/00 3/20/00 requested changes The preliminary site plan for UREF North Fork Business Park, Building 1 and 2, received on 9 March 2000 has been reviewed. The Engineering Department will recommend approval when the following items have been satisfactorily addressed. 1 Several grade lines terminate at the top (northern)edge of Sheet C-6 Please show the total extent of all grading. [18-32.5 6d] 2. The area enclosing building#2 is labeled "PHASE 1"along its eastern boundary and labeled "PHASE 2"along its southern boundary (sh. C-6). Please clarify [Policy] 3 Please show any retaining walls that may exist. Retaining walls 5-feet or taller will require and Engineers seal and signature. [Policy] 4 Please show proposed radii for the entrances [18-32.5 61] 5 Please indicate the available sight distance for entrances and left turn lanes. [Policy] 6 Provide plan revisions required by VDOT [Policy] The following items must be submitted with the final site plan for review by the Engineering Department. a. An erosion control plan, narrative, computations, application and fee. [18-32.7.4 3, 17-203] b. A stormwater management/BMP plan, computations, application and fee. Computations must include water quality, and detention routings for the 2yr and 10yr storms. [17-303,17-304] c. A completed stormwater management facilities maintenance agreement and fee, unless already completed. [17-304] d. Drainage computations. [18-32.7 4, Policy] Please contact me if you have.questions or require additional information. • 3/21/00 02:05 PM Page 1 of 1 of A 4gr ��RGIN�P COUNTY OF ALBEMARLE Department of Engineering&Public Works MEMORANDUM TO: Yadira Amarante, Planner FROM: Steven Snell and Mark Graham, Engineering DATE: 23 March 2000 RE: North Fork District#2, Building 1 & 2, preliminary site plan These comments are more of an advisory than a requirement for the preliminary plan, but should be addressed on the final plan. 1. The proposed sediment basin only works for the initial clearing phase. Once they initiate the proposed grading, the diversion dikes will be filled and perimeter control has been lost. Also, the grading shown on sheet c-6 indicates about 2/3 of the sediment basin area will be filled to construct the entrance road for this site. shown grading for existing PRA parking lot indicates some additional areas will drain to sediment basin. This means sediment basin drainage area should account for this area. 2. 2:1 slopes (horizontal:vertical) are not acceptable as mowed areas. Per the Virginia Erosion and Sediment Control Handbook, mowed slopes must be 3:1 or flatter. If the slope is not to be mowed, the applicant will be required to indicate the areas to receive groundcovers instead of grass as part of the Erosion and Sediment Control Plan. 3. The diversion dike"DD"shown on the northern perimeter should actually be a diversion "DV" . This is not critical because the shown diversion doesn't work during construction. The grading on sheet C-6 clearly shows this area will be regraded, preventing this diversion from ever working. 4. There is no provision for control sediment with the proposed storm sewer. The storm sewer is not shown on the erosion control plan and there is no mention of providing inlet protection. 5. As this road is now in the State highway system, it is doubtful they can place inlet protection across the existing inlets along Lewis and Clark Drive as proposed. Sediment control must be provided on site. 6. The construction entrance must be 12' x 70' paved wash rack with water supplied from a 1"meter and 1" tap connected to a 1 %z"hose with a 1"nozzle. Construction entrance must also have a sediment trap for the washed sediment. 7. The proposed storm sewer in the northwest corner of this site does not discharge into an existing drainage way. They will need to provide channel calculations demonstrating the • adequacy of the proposed channel,with respect to both capacity and velocity. 8. The drainage area for the topsoil stockpile exceeds that allowed for use of silt fence. They will need to provide other means of sediment control, possibly a sediment trap or basin. 9 The,engineer will need to demonstrate the adequacy of the channel for the storm sewer discharges with respect to both flow and erosive velocities where this water enters the existing stream. 1 10. The storm sewer e northeast corner of Building 1 can' .aply discharge onto the ground next to Lewis and Clark Drive. This is a curb and gutter street with a sidewalk between the discharge and the street. The storm sewer must connect to the existing storm sewer. Please contact me if you have questions or require additional information. Copy: file File:memo North Fork Town Center MAR: -17' 00 (PRI) 15;25 VDOT CV'' ' TEL 804 3759 P. 002 COMMONWEALTH of VIRGINIA DEPARTMENT OF TRANSPORTATION 701 VDOT WAY COMMISSIONER CHARLOTTESVILLE, 22911 A. G.TUCKER March 16,2000 RESIDENT ENGINEER Site Review Meeting March 23, 2000 Mr. Glenn E. Brooks - Dept. of Engineering 401 McIntire Road Charlottesville, VA. 22902 Dear Mr. Brooks: The following are our comments: SDP-00-024 North Fork Research Park Phase 2 Buildings 1 & 2 preliminary Plan,Route 29 • This site plan should include a running total of previously approved and currently proposed building areas for North Fork Park. • Plan should include note at entrance location stating that traffic signal, when warranted by VDOT, will be installed by the developer to VDOT specifications, • The median area will require grading to provide sight distance for left turns. A minimum 450' is required for left turn, however should the south side of the intersection develop, the entrance will require 525'. The 450' sight line will ' need to be established prior to Lewis and Clark Drive being accepted into the State System. • Recommend the proposed internal right turn lane be extended full width to the parking area. This will allow for additional storage when the site is fully developed and traffic signal is installed. • Drainage computations should be submitted for review. TRANSPORTATION FOR THE 21ST CENTURY �oFn RECEIVED tetiOW �'IRGIT`11P MAR 2 0 Joao COUNTY OF ALBEMARLE PLANNING AND Department of Building Code and Zoning Services COMMUNITY DEVELOPMENT 401 McIntire Road,Room 227 Charlottesville,Virginia 22902-4596 FAX(804)972-4126 TELEPHONE(804)296-5832 TTD(804)972-4012 MEMORANDUM TO: Yadira Amarante, Planner FROM: John Shepherd, Zoning Manager .111 DATE: March 20, 2000 RE: SDP-00-24 North Fork Research Park, District#2, Office Buildings #1 & #2 Preliminary Plan Dated March 6, 2000 The Albemarle County Department of Building Code and Zoning Services will approve the preliminary plan for zoning compliance when the following items have been satisfactorily addressed. The Building Official may provide separate comments. [Each comment is preceded by the applicable reference, which is to the Zoning Ordinance unless otherwise specified.] 1. [4.2, 4.2.3.2] Show the limits of the areas of slope that are 25% or more. Please be aware that earth disturbing activity within these areas may require a waiver from the Planning Commission. 2. [4.12.6.5 c] Curvilinear parking requires the approval of the Planning Commission. 3. [32.5.6 a] Note the tax map, parcel number and zoning on the parcels adjacent to the site. 4. [32.5.6 a] Add reference to ZMA 98-27 to the plan. 5. [4.12.6.6.1] Parking for office use is based on 1 space per 200 square feet of net (80%) office floor area. The parking statistics for both buildings must be revised accordingly. Building #1- 70,000 x 80% = 56,000 / 200 = 280. Building #2- 40,000 x 80% = 32,000 / 200 = 160 6. [4.12.7.4] Show the loading spaces dimensioned at a minimum of 12' x 25'. 7. [4.12.7.4 b] Loading spaces for offices are required on the basis of 1 space per 8,000 square feet of net office space. Building #1 requires 7 rather than 6 spaces UREF Dist. #2 Bldgs # 1 & 2 March 20 Page 2 based on 56,000 / 8,000 = 7. The parking statistics must be revised accordingly. Be aware the Planning Commission may reduce the required number of loading spaces based on the criteria contained in 4.12.7.6. 8. [32.5.6 b] I count 443 parking spaces serving Building #1 and 180 spaces serving Building #2. Please review these figures and correct the parking provided and the total buildout statistics accordingly. 9. [26.10.1] Please show a 10' building and 10' parking setback from Lewis and Clark Drive. 10.[ZMA 95-04] Show the buffer and Open Space as it was shown on Parcel B-8 on the Application Plan. 11.[ZMA 95-04] Proffer 3.1. In order to keep track of all the elements contained in 3.1, add the following elements to the total buildout schedule. • Include MicroAire and Motion Control. • Identify the square footage constructed per year beginning on June 12, 1996. • Based on the requirement that construction could not exceed 500,000 sf in the initial year and shall not exceed 200,000 sf plus undeveloped square footage, begin to tally the square footage that could be constructed now. 12.[ZMA 95-04] Proffer 4.4 Note on the plan, No single user will require more than 125,000 gallons per day (average daily consumption) of potable water without obtaining County approval. 13.[4.17.4] Note on the plan, "Each outdoor luminaire equipped with a lamp which emits 3,000 or more initial lumens shall be a full cutoff luminaire or a decorative luminaire with full cutoff optics." 14.[4.17.4.3] Note on the plan, "The spillover of lighting from parking area luminaires onto public roads and property in residential or rural areas zoning districts shall not exceed one-half('/z) foot candle." Final approval from the Department of Building Code and Zoning Services will be subject to the following conditions: (The following conditions are those that have been identified at this time. Additional conditions may be added or eliminated based on further review.) 1. [32.5.6 n] Show the location of all outdoor lighting on the plan.e UREF Dist. #2 Bldgs # 1 & 2 March 20 Page 2 2. [32.6.6 j] Provide a description and photograph or diagram and show the location of each type of outdoor luminaire that emits 3,000 or more initial lumens. Please be aware that installation of such luminaires in the future that are not shown on this plan shall require an amendment to this plan. 3. [32.6.6 j & 4.17.4 b] Include a photometric plan on the site plan demonstrating that parking area luminaires are in compliance with 4.17.4 b. Please contact me if you have questions or require additional information. l Albemarle County Development Departments SDP-2000-024 SPIN Submission and Comments North Fork District#2, Bldg#1 & #2 Prelim SDP Building prelim site plan revision 1 reviewer received reviewed decision Jay Schlothauer 3/16/00 3/21/00 approved Based on plans dated March 6, 2000 No comments or conditions. 1 3/22/00 11:59 AM Page 1 of 1 Albemarle County Development Departments SDP-2000-024 SPIN Submission and Comments North Fork District#2, Bldg#1 & #2 Prelim SDP Fire/Rescue prelim site plan revision 1 reviewer received reviewed decision Bruce Crow 3/16/00 3/21/00 approved with conditions ' Fire Lanes will be required Fire lanes shall be designated by signs and pavement markings as required by the Fire Offical. (Albemarle County Fire Prevention Code, Section 6-204) Fire Lanes will be required at the Fire dept. connection location, the front Island and along the north side service entrance of building# 1 Fire lanes will be required along the front travelway of building#2 and on the northside at the fire hydrant and fire department connection location Building # 1 will be required to be equipped with a fire department standpipe system with fire hose connection located inside the interior stairwells on each floor for parking to be allowed in front of the building. (Albemarle County Zoning Ordinance, Section 18-32.7 6) The dumpster on the north end of building# 1 is within 15' of the building Relocate the trash receptacle. Trash receptacles shall be located a minimum of 15'from any property line or building (Albemarle County Fire Prevention Code, Section 6-200, F-2103 3) 3/21/00 02:06 PM Page 1 of 1 Albemarle County Development Departments SDP-2000-024 SPIN Submission and Comments North Fork District#2, Bldg#1 & #2 Prelim SDP E-911 Mapping [description and date] revision 1 reviewer received reviewed decision Damon Pettitt 3/13/00 3/13/00 approved No action by E-911 Addressing Staff is necessary for FINAL approval. 3/21/00 02:05 PM Page 1 of 1 R .C .S .A . TEL :804-979-0698 Mar , '00 16 :01 No .020 P .02 • ALBEMARLE COUNTY SERVICE AUTHORITY MEMO Ta Yadira Q. Amarantee, Planner Peter C. Gorham, Senior Civil Engines FROM : DATE: March 23, 2000 r� Site Plan Technical Review for: North Fork Research Park Phase ?. Buildinas -1 & 2 (TM 32. Parcel 6A) The below checked items apply to this site. X 1. This site plan is within the Authority's jurisdictional area for: A. Water and sewer B. Water only C. Water. only to existing structure D. Limited service X 2. A 1.2, waterline is located onsite. 3. Fire flow from nearest public hydrant, located distant from this site plan, is gpm ± at 20 psi residual. _ 4. An A!!, sewer line is located onsite. 5. An Industrial waste Ordinance survey form must be completed. X. 6. No improvements or obstructions shall be placed within existing or future easements. 7. and _ plans are currently under review. 8. and plans have been received and approved. n 9. No plans are required. X 10. Final water and sewer plans are required for our review and approval prior to granting tentative (kn approval. - 11. Final site plan may/may not be signed. 12. RWSA approval for water and/or sewer connections. Comments: Final atnnroval will tempt be granted unti/ the water and sewer lines in the North Fora ,Research Park have been dedicated to and aoceptet per the Service Authority. Provide sanitary sewer and_water line easements.:to ad 4cent property. Backflow prevention devices rearu .red on domestic water services. The site plan does not show or incorrectly shows: meter locations - waterline size waterline locations sewer line size - sewer line locations expected wastewater flows easements expected water demands SDP-00-024