HomeMy WebLinkAboutSDP202100071 Plan - Submittal (First) 2021-08-20 (2)DRAWING INDEX Sheet 1 Site Plan 2 General Notes/ Design Parameters 3 Details 4 Wall A - Enlarged Site Plan 5 Wall A - Sta. 0 to Sta. 211.5 S \ W 42" Tall Safety Handrail or Fence w/ Sleeve -It SDI Fence -Post Anchoring System N Cap Unit Secure to Top Unit w/ Concrete Adhesive Anchor Diamond Pro Units E Drainage Aggregate Min 12" Thick VDOT No. 57 Stone We¢phol¢ w/Wall Drain Pro Daylight Pipe Through Wall 40' OC Spacing (Typ.) Compacted Backfill —' Stone Leveling Pad Crushed Stone or Sand 6" Min Thick x 24" Wide Non -Woven Filter Fabric Mirofi 140N or Equivalent —Geogrid Reinforcement (Typical) Refer to Wall Profile for Geogrid Type, 1 Geogrid Length (GL) and Location y 24" Vertical Spacing (Typ.) — _ — Retained Soil — _ Reinforced Fill —4" Dia. Drain Pipe Granular or Low Plasticity Soil (See Drain Detail) Compact To Min 95% Standard GL Proctor Density I See Wall Profile I TYPICAL RETAINING WALL CROSS SECTION i (Not to Scale) i L t 12-1/2"----------------- i i � I 12" Rear Lip 18 — 1" Setback 8-1/l2" 8" / 1 Scale: 1" - 40 FT .AN o® Anchor Diamond Pro Segmental Retaining Wall Southwood PHA - Blocks 11 & 12 Albemarle County, Virginia Site Plan Adapted From the Grading & Drainage Plan, Sheet No. C5.1, Dated May 14, 2021, Prepared by Timmons Group. Site Plan For Illustrative Purpose. Approx. Scale: 1" = 40 FT ANCHOR DIAMOND PRO UNIT (Not to Scale) Geotechnical 4tA Engineering, P.C. / 4 :. 8</ a Z/ zgy Srnle: 1" = 40 FT 5956 Buckland Mill Road Roanoke, Virginia 24019 Phone:(540) 366-2379 Project No. I RW-2640 NOTES: DESIGN PARAMETERS: 1.0 STRIP VEGETATIVE AND ORGANIC SOIL FROM THE WALL AND GEOGRID ALIGNMENT. 2.0 BENCH CUT ALL EXCAVATED SLOPES. 3.0 DO NOT EXCAVATE BEYOND EXCAVATION LINES SHOWN ON PLAN UNLESS DIRECTED BY THE GEOTECHNICAL ENGINEER TO REMOVE UNSUITABLE SOIL. 4.0 CONTRACTOR SHALL ENSURE TEMPORARY EXCAVATIONS ARE STABLE AND PROVIDE EXCAVATION SUPPORT IF NEEDED. 5.0 GEOTECHNICAL ENGINEER SHALL VERIFY FOUNDATION SOILS AS BEING COMPETENT PER THE DESIGN PARAMETERS. 6.0 LEVELING PAD SHALL CONSIST OF COMPACTED SAND, GRAVEL, OR COMBINATION AND SHALL BE A MINIMUM 6-INCH THICK LAYER WITH A MINIMUM WIDTH OF 24 INCHES. 7.0 A 4-INCH-DIAMETER SLOTTED DRAINAGE PIPE SHALL BE INSTALLED BEHIND THE WALL AND CONNECT TO WEEPHOLES INSTALLED AT THE BASE OF THE WALL (40 FEET ON CENTER) AND EXTEND BEYOND THE FINAL GRADE TO DAYLIGHT (SEE DRAIN DETAIL). 8.0 DRAINAGE AGGREGATE AND UNIT (CORE) FILL SHALL CONSIST OF CLEAN ANGULAR GRAVEL (VDOT NO.57 STONE), MEETING THE FOLLOWING GRADATION AS DETERMINED IN ACCORDANCE WITH ASTM D-422. SIEVE SIZE PERCENTAGEPA55ING 1-112 INCH 100 1 INCH 95-100 1/2 INCH 25 - 60 NO.4 0-10 NO. 8 0-5 9.0 GEOGRIDS SHALL BE LAID HORIZONTALLY ON COMPACTED BACKFILL FOR THE REQUIRED GEOGRID LENGTH (GL) IN THE TENSILE STRENGTH DIRECTION (PERPENDICULAR TO WALL FACE) NOTED ON THE WALL PROFILE. THE GEOGRID SHALL BE PLACED WITHIN ONE INCH OF THE FRONT FACE OF THE UNIT BELOW AND EXTEND HORIZONTALLY OVER COMPACTED FILL. 10.0 ANCHOR DIAMOND PRO UNITS MOLDED DIMENSIONS SHALL BE 8 INCHES HIGH BY 18 INCHES LONG BY 12 INCHES DEEP AND SHALL NOT DIFFER MORE THAN + 1/8 INCH IN ANY DIMENSION. 11.0 A 1-INCH SETBACK PER UNIT (REAR LIP) SHALL BE MAINTAINED FOR PROPER BATTER (I.E. 7 DEGREE CANT FROM VERTICAL). 12.0 GEOGRIDS SHALL BE PLACED WITHIN 1 INCH OF THE FRONT FACE OF THE UNITS AND GEOGRID5 PULLED TIGHT (AFTER PLACEMENT OF THE NEXT COURSE OF BLOCK UNITS) TO REMOVE SLACK AND TO INTEGRATE GEOGRIDS AND UNITS. 13.0 FIELD ADJUSTMENTS OF BLOCK ALIGNMENT MAY BE MADE ON NON -REINFORCEMENT LAYERS WITH THE USE OF SHIMS OR ASPHALT SHINGLES TO RAISE ONE COURSE OF BLOCK BY A MAXIMUM OF 1/4 INCH VERTICAL HEIGHT. 14.0 REINFORCED FILL SHALL CONSIST OF GRANULAR SOIL FILL WITH U5C5 SOIL TYPES GP, GW, GM, GC, 5W, SP, SM OR 5C WITH A MINIMUM ANGLE OF INTERNAL FRICTION, OF 30 DEGREES AS OUTLINED IN DESIGN PARAMETERS - NOTE 5. LOW PLASTICITY CLAYEY SAND (SC), SILT OR CLAY (ML-CL) CAN BE USED SUBJECT TO APPROVAL BY THE GEOTECHNICAL ENGINEER. MAXIMUM PARTICLE SHALL BE LIMITED TO 4INCHES IN DIAMETER. THE FINE FRACTION (MINUS NO. 40 SIEVE) SHALL HAVE A MAXIMUM LIQUID LIMIT (LL) OF 40 AND A MAXIMUM PLASTICITY INDEX (PI) OF 20. THE BACKFILL SHALL BE FREE OF DEBRIS AND ORGANIC MATTER. HIGHLY EXPANSIVE SOILS (MH-CH) SHALL NOT BE USED IN THE REINFORCED FILL ZONE. 15.0 REINFORCED FILL SHALL BE PLACED IN 8-INCH LIFTS AND COMPACTED TO A MINIMUM OF 95% OF MAXIMUM STANDARD PROCTOR DENSITY (A5TM D-698) AND WITHIN + 3 PERCENTAGE POINTS OF OPTIMUM MOISTURE CONTENT. COMPACTION TESTS SHALL BE PERFORMED AS THE WALL IS INSTALLED. COMPACTION WITHIN 3 FEET OF THE WALL SHALL BE LIMITED TO HAND -OPERATED EQUIPMENT. 1 BUILDING CODES: 2015 VIRGINIA UNIFORM STATEWIDE BUILDING CODE (USBC) AND 2015 INTERNATIONAL BUILDING CODE (IBC). 2 THE WALL PROFILE IS BASED ON THE GRADING & DRAINAGE PLAN, SHEET NO. C5.1, DATED MAY 14, 2021, PREPARED BY TIMMONS GROUP. 3 WALL DETAILS SHOWN ON THIS PLAN ARE FOR ANCHOR DIAMOND PRO SEGMENTAL RETAINING WALL (SRW) UNITS MEETING THE NATIONAL CONCRETE MASONRY ASSOCIATION (NCMA) CRITERIA FOR SRW WALL SYSTEMS. 4 ENGINEERING ANALYSIS BASED ON USE OF STRATAGRID 5GU60 GEOGRIDS. OTHER COMPATIBLE GEOGRIDS MAY BE SUBSTITUTED WITH THE APPROVAL OF THE WALL DESIGN ENGINEER. 5 THE DESIGN OF THE SEGMENTAL RETAINING WALL (SRW) ASSUMES THE FOLLOWING PARAMETERS: Ym, Moist FRICTION SOIL SOIL UNIT WEIGHT ANGLE COHESION CONDITIONS Type (PCF) (DEG) (PSF) REINFORCED FILL Granular or Low Plasticity Soil 120 30 0 RETAINED SOIL Elastic SILT (MH) 115 26 0 FOUNDATION SOIL Elastic SILT (MH) 115 26 100 16.0 A VIBRATORY PLATE TAMPER SHALL BE USED TO DEN5IFY NO.57 STONE. COMPACTION TESTS CAN BE WAIVED WHERE NO.57 STONE IS USED AS REINFORCED FILL. 17.0 CONTRACTOR SHALL SLOPE SITE GRADES TO DIRECT SURFACE RUNOFF AWAY FROM WALL AT END OF EACH DAY TO AVOID WATER DAMAGING THE WALL WHILE UNDER CONSTRUCTION. 18.0 ANY SURFACE DRAINAGE FEATURES, FINISH GRADING, PAVEMENT, OR TURF SHALL BE INSTALLED IMMEDIATELY AFTER THE WALL IS COMPLETED. 19.0 IF SITE AND SOIL CONDITIONS, WALL GEOMETRY, OR WALL LOADING ARE DIFFERENT THAN THE DRAWINGS AND THE DESIGN PARAMETERS, THE CONTRACTOR MUST CONTACT THE WALL DESIGN ENGINEER PRIOR TO PROCEEDING WITH THE CONSTRUCTION OF THE WALL. 20.0 DETAIL FOR HANDRAIL POSTS AT THE TOP OF THE WALL IS PROVIDED FOR PLACEMENT OF P05TS BEHIND THE WALL. 1" Setba6 7pen Cells Filled With Stone) 1" Rear Lip UNIT CONNECTION DETAIL (Not to Scale) 6 SOIL STRENGTH PARAMETERS ARE BASED ON USE OF GRANULAR OR LOW PLASTICITY SOIL IN THE REINFORCED FILL ZONE. ALL SOIL FILL SHALL BE PLACED IN MAXIMUM 8-INCH LIFTS AND EACH LIFT IS COMPACTED TO A MINIMUM OF 95% OF MAX. STANDARD PROCTOR DENSITY, AND WITHIN + 3 PERCENTAGE POINTS OF OPTIMUM MOISTURE CONTENT, USING PORTABLE COMPACTION EQUIPMENT. DO NOT USE HIGH PLASTICITY CLAY (CH-MH), ROOTS OR TOPSOIL IN REINFC ZONE. ANY SOFT, SATURATED SOIL ENCOUNTERED IN 5UBGRADE SHALL BE UNDERCUT AND REPLACED WITH CRUSHED STONE TO STABILIZE THE FOUNDATION 5UB6RADE OR AS DIRECTED BY THE GEOTECHNICAL ENGINEER. WALL A - MAX. WALL HEIGHT = 7.33 FEET (INCLUDING EMBEDMENT) FRONT SLOPE (PARKING LOT) = LEVEL BACKSLOPE BEHIND THE WALL = MAX. 2.5H:1V WITH DRAINAGE SWALE SURCHARGE AT TOP OF WALL = NONE MIN FACTOR OF SAFETY (SLIDING) = 1.5 MIN FACTOR OF SAFETY (OVERTURNING) = 2.0 MIN FACTOR OF SAFETY (BEARING CAPACITY) = 2.0 DESIGN SOIL BEARING PRESSURE = 1,500 PSF (SEE NOTE ON WALL PROFILE) MICHAEL R.,CIRD No. 021245 Albemarle Circeo Geotechnical Engineering, P.0 nia 5956 Buckland Mill Road Roanoke, Virginia 24019 Phone:(540) 366-2379 Scale: N/A I Project No. I RW-2640 Date: 08/08/21 r- 17 a° i 7u u t TW 497.76' BW 495.83' T W 495.19' RW 404 77' / I ENLARGED SITE PLAN / --1 `III I I VIM 05coie: r� Anchor Diamond Pro Segmental Retaining Wall Wall A Only) Ep,LTRI Southwood PHA -Blocks 11 & lz g g y) 4 O,. Albemarle County, Virginia �� Southwood PHA -Blocks 11 &12� CIRCEO GEOTECH HEMCirceo 5956 Buckland Mill Road < ' � Geotechnical Albemarle CountyVirginia VO MICHAELR-CIRCE �4 Engineering,P.0 Roanoke, Virginia 24019 ' g No. 0?1245 1 Phone: (540) 366-2379 Site Plan Adapted From the Grading & Drainage Plan, Sheet No. C5.1, 0 / 4 Dated May 14, 2021, Prepared by Timmons Group. �C'x 8` a/z/ . � Scale: 1" = 20 FT Site Plan For Illustrative Purpose. Approx. Scale: 1" = 20 FT �SS+ONAL ECG\ Date: 08/08/21 Project No. RW-2640 Revision: --- Sheet 4 of 5