Loading...
HomeMy WebLinkAboutSDP202100065 Review Comments Final Site Plan and Comps. 2021-09-03t� OF ALB County of Albemarle COMMUNITY DEVELOPMENT DEPARTMENT Site Plan review Project title: Albemarle Business Campus Block 1: Final Site Plan Project file number: SDP2021-00065 Plan prepares Shimp Engineering, 912 E. High St. Charlottesville, VA 22902 Keane Rucker [ keane e shimp-engineering corn ] Owner or rep.: 51' Street Forest LLC / 250 W. Main St., Ste. 201 Charlottesville, VA 22902 [ kyle.redinaer(a),gmail.com ] Plan received date: 3 Aug 2021 Date of comments: 3 Sep 2021 Plan Coordinator: Andy Reitelbach Reviewer: John Anderson 401 McIntire Road, North Wing Charlottesville, VA 22902-4579 Telephone:434-296-5832 WWW.ALBEMARLE.ORG 1. Site plan approval requires WPO plan approval. 2. WPO plan approval requires easement plat recordation for on -site SWM facilities. 3. Provide public drainage easement for sections of storm pipe downstream of SWM facilities. 4. C1 5. C6 a. Please list associated and active WPO plan for this parcel: WPO201800044, VSMP Plan Amendment, Royal Fern Phase 1, Now ABC Borrow Site. b. Please submit WPO201800044 Amendment #2 Application at earliest convenience. a. Provide and label CG-12 at site entrance. b. Clearly label ramp and curb type at HC-parking spaces. c. Label HC-parking space signs, provide typ. detail for HC-parking space signs. d. Provide pavement markings or yield -stop sign to establish internal parking circulation right-of- way. e. Label curb types (CG-2, CG-3, CG-6, roll-top, etc.). f. Please label feature that appears to be an outdoor court between the clubhouse and building 102. g. It is unclear whether site plan geometry at north end of parking lot allows adequate turn radius for fire rescue apparatus. Engineering defers to ACF&R. h. Provide and label ramps at either end of 4' stamped concrete pedestrian path. i. Revise design to avoid sight line conflict at south comer of building 102. I. Stripe pedestrian crosswalk at site entrance. 6. C4 a. Please provide prominent plan label to identify portions of ABC development east of Old Lynchburg Road as Not Included in Final Site Plan for ABC, Block 1. b. Recommend labeVs (for portion excluded from ABC Block 1) identify plans that correspond with (and approve designs for) ABC, Block 5, i.e.: SDP202100022, WPO202000058. 7. CT Provide bypass for Stormtech systems, should system outlets (low flow weir orifices) obstruct. Consider system failure. Provide bypass piping details (sheet C9) with next submittal. 8. C8 a. Obtain public drainage easement for new storm pipe downstream of SWM facilities proposed to be off -site, from property line to the point new storm pipe connects with existing storm network on Mountainwood Road. b. Provide safety railing labels and railing details for retaining walls >4'. c. Note: A separate building permit is required for wall In. >3-ft, unless integrated into building design. Engineering Review Comments Page 2 of 2 d. Note: Sealed geotechnical design is required for retaining wall ht. >4' unless wall is integrated into building structural design, in which case it is reviewed with that building permit application. 9. C9 a. Str. A3, A4: Provide note for %:" steel plate in floor, since INV IN — IW OUT >4'. b. Design appears to route impervious area runoff from 3-1/2 residential buildings plus clubhouse and perhaps 2/3 of all paved parking to a 158 LF 60" StormTechTM system, while runoff from just 1-1/2 residential buildings and 1/3 of site parking route to a 125LF 60" StormTech chamber detention /treatment system. WPO plan should clarify disparity in runoff vs. detention /treatment system capacity. Note: the 125 LF system also appears to route to or through the 158 LF system. c. Provide LD-204, LD-229 storm inlet and storm drain design computations. Additional comments on drainage design possible. 10. C 16: Please include primitive path detail. 11. C 17: Engineering defers to VDOT on MOT plan for public rights -of -way. Please feel free to call if any questions. Thank you I Anderson 434.296-5832 -x3069 SDP202100065 Albemarle Business Campus block I FSP 090321.doc