HomeMy WebLinkAboutARB202100086 Checklist 2021-09-09SIGN REVIEW CHECKLIST Flow Audi 21-86
REF
CHECKLIST ITEM
NOTES
GENERAL ISSUES
❑
10
Coordination (sign type, size, placement, illumination,
Proposal is as approved with CSP
color, and/or font) is required for multiple business centers
signs
❑
10.c
Sign compatibility maintained through color or font and
typeface selection.
❑
10.a
The future review for new signs in an existing multiple
business center will take into consideration the
compatibility with the existing building(s) and si s .
❑
Appendix
Color, form, surface pattern, shape, and disposition of
A.A.4
elements and openings in an architectural design can affect
our perception of scale and can impact the appearance of a
sign on a building.
❑
IL General
Consider all standard sign guidelines.
Sign
Guidelines
TYPE
❑
IO.b
All wall signs in a multiple business center must utilize the
Proposal is as approved with CSP
same sign e.
❑
10.a
The first approved sign installed in a multiple business
center will establish the standard for all future signs for that
center.
LOCATION
❑
9.a
Wall signs must integrate with the building's architecture.
Signs are aligned across the elevation.
The sign placement should not obscure architectural
Signs are to be installed on the glass storefront, as
features or details, (such as cornices, windows, columns,
approved with CSP
pilasters and paneling).
0
10
Unified sin placement is required; signs must be placed on
Signs are aligned across the elevation.
REF
CHECKLIST ITEM
NOTES
the building to establish a unified appearance.
SCALE AND PROPORTION (multiple businesses
❑
Appendix
A ratio of 1/3 text to 2/3 wall area or 1/4 text to 3/4 wall
Considerable open wall area is available.
AA
area is a good working proportioning system for placing a
sign.
❑
9. d
Degree of visibility, the distance from the Entrance
The building is close to the street, proportions
Corridor, and the architectural design of the building/area
appear balanced.
will determine sign size, placement, and proportions.
An appropriate height for channel letters in a 30" high sign
Letters are 1' 8" and F tall. Available wall area is
band is 18".
much taller than 30"
This allows 6" of unoccupied space above and below the
letters.
4" of clear space above, below, and to the sides of a channel
letter sign is considered a minimum, with larger clearances
required for larger sign bands.
ARB
Disregard approved comprehensive sign criteria when a
n/a
Directive
multi -tenant building becomes a single tenant building, with
11-19-12
the understanding that if/when the building is again
meeting
occupied by multiple tenants either the previously approved
criteria will be reinstated and all new and existing signs will
conform to those criteria, or new criteria will be proposed,
reviewed and approved.
SIGN REVIEW CHECKLIST
REF
CHECKLIST ITEM
NOTES
TYPE
❑
9.b
For internally illuminated signs, channel lettering
Channel letters proposed
(mounted on a raceway or individual letters) is preferred to
cabinet signs.
❑
5.b
When channel letters cannot be adequately accommodated,
n/a
internally illuminated cabinet signs may be considered.
❑
6
Reader boards are discouraged.
n/a
MATERIALS
❑
4. c
Materials used in the sign should complement the building
Standard sign materials are proposed.
being served by the sign.
COLOR
❑
4.e
Color for raceway -mounted channel letters, the raceway
Pipe standoffs used on glass
shall match the wall color.
Sign colors must be harmonious with each other.
Red, silver, white, black are harmonious
Sign colors must not clash with the site, when viewed in
Sign colors are coordinated with building colors
daylight and at night.
Overly intense color, (such as dayglo or fluorescent
Colors are not overly intense
colors), are prohibited.
Use of three colors or less (black and white considered as
4 colors will appear harmonious
colors)
Additional colors may be approved if they contribute to the
sign balance/unity.
SIZE, SCALE, PROPORTION, AND LOCATION
❑
4.b
Signs may not exceed the size, height and setback
requirements as outlined in Section 4.15 of the Albemarle
County Zoning Ordinance unless sign has a variance).
❑
Appendix
A ratio of 1/3 text to 2/3 wall area or 1/4 text to 3/4 wall
The signs do not appear over -scaled on the available
AA
area is a good working proportioning system for placing a
wall area.
REF
CHECKLIST ITEM
NOTES
sign.
❑
Appendix
Color, form, surface pattern, shape, and disposition of
The signs appear coordinated across the building
A.A.4
elements and openings in an architectural design can affect
elevation.
our perception of scale and can impact the appearance of a
sign on a building.
❑
9.d
The wall sign's size must coordinate with the architectural
The signs do not appear over -scaled.
element's size.
The sign should not over -crowd the architectural element,
the wall, or the sign area.
Buildings and building elements should not be used as
billboards.
❑
9.a
Wall signs must integrate with the building's architecture.
Signs appear integrated and don't obscure architectural
features.
The sign placement should not obscure architectural
features or details, (such as cornices, windows, columns,
pilasters and paneling).
❑
9.d
An appropriate height for channel letters in a 30" high sign
Signs are 1' and 1' 8" with wall area much taller than
band is 18".
30".
This allows 6" of unoccupied space above and below the
letters.
4" of clear space above, below, and to the sides of a
channel letter sign is considered a minimum, with larger
clearances required for larger sign bands.
Degree of visibility, the distance from the Entrance
Corridor, and the architectural design of the building/area
will determine sign size, placement, and proportions.
❑
4. d
Lettering should be in proportion (font size and typeface
The signs appear balanced on the building.
style) to the sign and the building.
REF
CHECKLIST ITEM
NOTES
Use of three typefaces or less.
2
Additional typefaces may be approved if they contribute to
a balanced/legible/unified sign design.
❑
9.e.iv
The width of the outline must be in proportion to the width
No outline
of the letter.
An outline width of 1/8" has been found to be an
appropriate sign dimension.
TRADEMARKS, CORPORATE LOGOS AND GRAPHICS
❑
4.f
The ARB may require that the color and scale of standard
Ring logo proposed. Size and colors are compatible
templates for trademarks, service marks, corporate logos
with letters and architecture.
and graphics be modified.
When used, trademarks, service marks, corporate logos
and/or graphics should be incorporated as an integral part
of the overall sign.
❑
5. a
External (or no) illumination is preferred for approved
Internal is proposed and is typical in the area and
graphics/logos;
approved with CSP
❑
5.b
internal illumination may be considered for approval on a
case -by -case basis.
LIGHTING
❑
9.e.i
External or no illumination is preferred for wall signs.
Internal is proposed and is typical in the area and
approved with CSP
❑
5.f
Any internal illumination is considered to contribute to
visual clutter and will be limited.
❑
5.c
Internal illumination design approval will be evaluated on
size, balance, complexity, and distance from the Entrance
Corridor.
❑
9.e.iv
The backgrounds of such cabinet signs must be made
No cabinets proposed for wall signs.
opaque zero light transmission).
❑
5.e
External illumination should be shielded and not create
Tare.
All external light sources shall be white.
❑
9.ii
Sign lighting external should be shielded so that it
REF
CHECKLIST ITEM
NOTES
illuminates only face of the sign and does not shine beyond
the edge of the sign.
❑
9.#i
Channel letters with translucent faces must have no light
Letters have aluminum backs. 1" of return has
spilling outward from the top, bottom, sides or back.
day/night acrylic.
Faces and returns of channel letters shall be opaque when
back -lit (halo -lit).
❑
9.iv
Cabinet signs shall have a non -illuminated background, or
No cabinet wall signs proposed.
an opaque zero light transmission background.
Cabinet signs shall be constructed such that no light spills
outward from the top, bottom, sides or back.
❑
5.g
All illumination shall be non -blinking.
n/a
❑
5.h
An exposed light source that forms the body of a sign,
n/a
(such as exposed neon signs), shall not be used in the
Entrance Corridors.
ARB ACTIONS
❑
Deleted
ifLED ligh ng i the drawing
proposea sign must state
following
The level ,.r;n,,,.,ina fi,,,, a by, the r iD hght.....;n
pre„;a
6/3/19
30 miffiamp (ma) neon.
ARB
action
❑
Action on ARB-P
Red acrylic #2283 has been determined to be an
2793 proposed for Audi letters
(BP)2001-12
inappropriate color for signs. Pantone color match
Wood Grill
for 2283 is 485C. Red #2793 has been approved
as an acceptable substitute. Pantone color match
for 2793 is 187C. See below.
12/21/15 action on
Generally, for signs in the Entrance Corridors, red 485
n/a
ARB 2015-114 & -
may be acceptable on a case -by -case basis as a
115 Shell Signs
secondary color.
ARB
Visual clutter resulting from adjacency, for example at the
Multiple signs proposed but they are spread out across
Action
Hardee's locations, is a reasonable basis for not allowing
the building elevation.
REF
CHECKLIST ITEM
NOTES
Memo:
illumination of the graphic.
5/7/12
ARB
Accent color letters can be used in a sign when portrayed
n/a
Action
as a graphic, up to 33% of the length of the sign.
Memo:
8/3/2015
WALL SIGNS - PROPOSED CRITERIA
SIGN LOCATIONS
See pages 4-7 for placement details
SIGN TYPE
Channel letters & Channel Logos
TEXT COLOR(S)
Red, Black, Silver/Chrome or Blue
SIGN MATERIALS
Aluminum, Acrylic, Vinyl or Paint Decoration
GRAPHIC COLORS)
No limittothe overall graphic colorsas long
as individual tenant graphics, and signs that are
In close proximity to each other, are limited to
three and all colors have a coordinated
appearance.
RACEWAY COLOR (IF USED)
To match the wall to which it is attached.
ILLUMINATION
Text may be face -lit only. Logos/graphics may be
face -lit or reverse/halo illuminated.
Illumination to comply with Albemarle
Co. Code CH. 18, Sec. 4.15.17.
All Illumination shall be non -blinking. All logo
backgrounds will be opaque.
SIZE LIMITATIONS
Per Albemarle Co. Code CH. 18, Sec 4.15.10, Sign
sizes are also subject to EC sign guidelines
requirements, which could result in signs smaller
than ordinance maximums.
NOTES: NAGMMS ARE SHOWN FOR REFERENCE ONLY. ACTUALTENANTLGNSWILL REFLECT
INDIVIDUAL TENANT IDEN rTYTHROUGH SHAPE FONT,.Err— SUBJECT TO K GUDELINES REGARDING
SIZE, COLOR PROPORrION, ETC
ALL SIGNS WILL REQUIRE INDIVIDUAL SIGN PERMn APPUCATIONS
Signs are in approved locations
Red, black, silver and nighttime white proposed
silver
Stand-off pipes proposed
Text is face lit. logo is internally lit.
Zoning has approved.