HomeMy WebLinkAboutSDP198200012 Action Letter 1982-04-02 NI i OF ALBS Gw �p F A/\ ���� Aipll: \ L✓kG1N%7' Department of Planning ROBERT W. TUCKER. JR. 401McIntire Roadn� RONALD S. KEELER DIRECTOR OF PUNNING Charlottesville, Va. 22901-4596 ASSISTANT DIRECTOR OF PLANNIP 804/296-5823 R. KEITH MARE PRINCIPAL PLANNER NANCY MASON CAPERTON •ENIOR PLANNER KATHERINE L. IMHOFF PLANNER MEMORANDUM DATE: April 2, 1982 TO: Messrs. J. W. Wright F, F. A. Kessler FROM: N. Mason Caperton, Senior Planner (?[ 7C RE: Site Review Committee Comments - Real Estate III, West, Office Building "Z" Site Plan The Site Plan Review Committee reviewed the above referenced site plan on April 1, 1982 . Please revise your site plan to include the following comments. Five copies of the revised plan must be submitted by 5 :00 P•m• , Monday April 12. 1982 , in order for the Planning Commission to review it on April_ 20. 1982 , at 7:30 p.m. , in Meeting Room If5/6, Second Floor, County Office Building, 401 McIntire Road , Charlottesville, Virginia. It is the Planning Commission ' s policy that revised plans and other requested information be submitted by the above date or the item will be deferred for at least one month. Please note that these comments should not be considered final . THE APPLICANT OR A REPRESENTATIVE MUST BE PRESENT FOR THE PLANNING COMMISSION MEETING. No site plan will be reviewed by the Planning Commission without all applicable technical information as required by the Site Plan Ordinance. To assist the applicant and the Staff in this, please submit the appropriate check list along with the revised copies of the site plan. Also, please read any comments from other agencies which are attached with this letter and contact me if you should have any questions. Thank you. 1. Please note the following technical information on the site plan: a. Correct the address of the owner to P. 0. Box 8186, Charlottesville, 22906; b. Note spot elevations; c. Note any utility easements; d. Note pipe sizes of sewer line; e. Note type surfacinf of sidewalks; f. Note typical size of parking spaces, aisle widths, number loading spaces and handicap spaces; 2. A cooperative parking agreement is needed. 3. Provide a more detailed landscaping plan. 4. The construction of Building "Y" must be substantially completed (and/or bonded) prior to the issuance of a certificate of occupancy for Building "Z" to ensure Wright & Kessler Page 2 that it has adequate parking and access. 5. See attached comments for additional information and requirements. NMC/jcw APPLICATION kQt2 �.CJ11kA Q_ , VI/r ,. 3Gu�1h1 "z ,.54 aid, THE RI I i ED PLANS AND F���TZI oN REQUESTED BELOW ARE DUE BY 5:00 p.m. , ON M Planning Staff Comments (cont) In addition to the above technical items and recommendations, the Planning Commission requires that the items listed below be supplied by the applicant by the deadline for revisions. The applicant is responsible for obtaining the approvals and information for those items checked below. Please contact the appropriate agency or department as soon as possible to allow sufficient time for completion of the requested information. ** Failure to submit this information will result in automatic deferral of the plat/plan for at least one month or a recommendation for denial . • HEALTH DEPARTMENT, CONTACT JACK COLLINS, 295-0161 Written Health Department approval Soil Scientist report COUNTY ENGINEERING DEPARTMENT, CONTACT TOM TREVILLIAN, 296-5861 Preliminary road plans/profiles (State and private roads) Review of adequacy of existing private roads for total number of lots to be served ✓ Pavement specifications (* ct Ota_- 'J p d US / Preliminary runoff control/stormwater detention approval ✓ Preliminary drainage plan approval Other FIRE OFFICIAL, CONTACT IRA CORTEZ, 296-5832 Preliminary Fire Official approval • PLANNING STAFF Slope study to determine adequate building site (includes sufficient area for 2 septic drainfields, house site, etc. ) ; specify approximate area of buildable area Other ✓ 1/ OF ALS "1.044 God ��° " 4 4. U wD pf: • RODfiRT E. VAUGHN Inspections Department H. P. CLARKE DIRECTOR or INSPECTIONS BUILDING OFFICIAL. ZONING ADMINISTRATOR BL ILDING, ZONING, SOIL EROSION JESSE HURT FIRE PREVENTION DEPUTY ZONING ADMINISTRATOR 401 McIntire Rd. IRA B. CORTEZ CHARLOTTESVILLE, VtRGINIA 220ot-4596 FIRE PREVENTI::N OFFICER (804) 296.8832 DATE March 24, 1982 TO: N. Mason Caperton , Planner FROM: Fire Prevention Officer RE: Site Plan, Technical Review For Real Estate III - Building 2: - 3 story The below checked items apply to this site and are hereby recommended to the Commission: X 1. Hydrants are required and must meet the following requirements: X A. 212 C&O threads. X B. Located on highway right-of-way (when possible) . X C. No closer than 50' or more than 400' to each major structure. D. Every 800' along the roadway. E. Every 500' around the perimeter of the building. X F. The fireflow requirement is 1,250 gallons per minute @ 20 PSI (residual) . 2. A dry hydrant with adequate water from a pond is required. The surface to the dry hydrant shall be accessable by use of an all weather compacted surface with a grade of not more than 20% and a turn-around space with a radius of 90 feet the standpipe shall have a 412" national standard male fitting (see NFPA 1231) . 3. Dumpster location shall not be closer than 30' to any structure. 4. Handicapped provisions are required (see code of Virginia 35-124 & BOCA Basic Building Code Article 316) . X 5. Other comments and recommendations all structures over 35' high require FPE approval (sprinklers) . The attached plans do not show or incorrectly show: Hydrant locations X Handicapped facilities x Hydrant flow including curb cuts & ramps Dumpster locations Other . ENGIT�FFRING DEPARTMENT SITE DEVELOPMENT PLAN CHECK LIST r 11 A Parcel Name: REAL. 57AT� � Z $IT.. RL41J DATA : 3—z4—B Z ROADWAYS Pavement specs. R/W lines Travel way 7 20' Easements . Drainage Urban curbing Parking details Sidewalks Cul-de-sac'7200' Radius Scale V • Geometry State/Private ST2 T 5►�rJs DRAINAGE Stoiniwater det. Runoff control Drainage layout Pipe, sizes Streams, ponds Easements Topo map Flood plain UTILITIES Water 1/ Hydrants - V Valves Gas Sanitary Sewer v Profile Soil Erosion Plan? 10,000 sq. ft. q. p FF " , 0 MAR 24 1982 COMMENTS: - PLA 1NG DEPT. DY ( ' �.�'-, ..... 7, . r L 6„,,,„1_,_ 0,. . .eiLbi 62 A-H-)01111- Planning Commission Meeting : April 20 , 1982 Contact Person : N . Mason Caperton ** ( 5 ) Real Estate III , West Office Building "Z" Site Plan : Public water and sewer are available . A 10" water main runs through the parking area along the west side of proposed building "Z" . An 8" sewer line with a manhole is located on the east side of proposed building "Z" . This existing 8 " sewer main shall be dedicated to and accepted by the Service Authority prior to connection of the sewer service for building "Z" . Expected fire flow for this area would be approximately 1100 gpm at a residual pressure of 20 psi and the static pressure expected would be approximately 60 psi . This project is in the Service Authority' s jurisdictional area . ( 6 ) McKinley Final Plat : Public water and sewer are not available . This project is outside the Service Author ty ' s jurisdictional area (approximately 10 miles west ) . ** ( 7 ) 7-Eleven Store Site Plan : Public sewer is not availabl'. Public water is available from a 8" water main on the ti \ / north side of State Route 649 approximately 160 feet east of the southeast corner of the 7-Eleven parcel . { 6 expected fire flow at 20 psi residual is 620 gpm from the nearest hydrant (approximately 200 feet ) on State A Route 649 . The static pressure should be around 60 psi . This project is in Service Authority ' s jurisdictional area . *`( 8 ) John Bosely Final Plat : Public water and sewer are not available . This project is outside the Service Authority ' s jurisdictional area (approximately 2 miles west by road) . ( 2 ) • lIcsAvEi) MAR 24 192 PLANNING DEPT. sit „ ,r, ;tt-,,il,,/ hi (1/0/ f/ ,i�MARE ,')-i:,r'UTTES. LLE F UVANNA GUN', ,'ALMY At i.r,a ; (/ /, ': r ;REENE COUNTY'S TANAROSvILLEI P() I)O i fn L GUtSA C OUNTY JJWSAt ff NELSON COUNT/ LOVINGs''ONt tI )Putt, 1' ,�f( 5 t�,it;,,lr 'P,,, '!l,-ll!l,/ MEMORANDUM T0: Mason Caperton, Senior Planner and Katherine L. Imhoff, Planner FROM: Jack Collins L,' -`- DATE: March 23, 1982 SUBJECT: Site Review Committee Meeting, April 1, 1982, 10:00 A.M. 1. Frances A. Shifflett Final Plat - health dept. has not been contacted. Will need health dept. approval. 2. W.W.W. Electronics Site Plan - health dept. has not been contacted. There is an existing septic system, but may be some question on enough area for additional building and area for an alternate drainfield and area needed for new addition. 3. Talbott's Gasoline Sales and Automobile Laundry Site Plan - Public sewer and water. 4. Berkmar, Lots 15A and 16A, Revised Final Plat - Public water and sewer. 5. Real Estate III, West, Office Building "Z" Site Plan - Health dept. has not been contacted. Will probably be served by public water and sewer. 6. McKinley Final Plat - Health dept. has not been contacted. Will need our approval. 7. 7-Eleven Store Site Plan - Health dept. has given preliminary approval for septic tank system. 8. John Bosely Final Plat - Health dept. has not been contacted. Will need either soil scientist report or backhoe holes. JC:as U.S. 6r)11 ent4PALTifier& c CONTACT PERSON: Katherine L. Imhoff 1. Frances A. Shifflett Final Plat - Soils in this area are Braddock loam and Thurmont loam. These soils are red with very sticky clay subsoils. They have moderate limitations for septic tank absorption fields because of a wetness condition. Depth to bedrock is greater than 60 inches. 2. W. W. W. Electronics Site Plan- No comment. 3. Talbott's Gasoline Sales and Automobile Laundry Site Plan- No comment. 4. Berkmar, Lots 15A and 16A, Revised Final Plat- No comment CONTACT PERSON: N. Mason Caperton 5. Real Estate III, West, Office Building "Z" Site Plan - No comment. 6. McKinley Final Plat- Soils consist of Glenelg and Hayesville loam. These are deep well drained soils with hard rock deeper than 60 inches. 7. 7-Eleven Store Site Plan- No comment. 8. John Bosely Final Plat- Soils in this area consist of Hayesville loam. This is a deep well drained soil with bedrock at 60 inches. nmc HAROLD C KING COMMISSIONER LEO E SOCCER,III • E NE M PANE GRUNDY BRISTOL DISTRICT A DEPUTY COMMISSIONER&CHIEF ENGINEER '! r J T WARREN T GEORGI vAUGHAN JR GALAX SALEM DISTRICT ,D; k' DIRECTOR OF ADMINISTRATION WILLIAM R WATKINS SOUTH BOSTON,LYNCHBURG DISTRICT .t. _,/ J M WRA V,JR J WILLIAM F MOHR RICHMOND RICHMOND DISTRICT 1 '- y, ' DIRECTOR OF OPERATIONS RICHARD G BRIDGES VIRGINIA BEACH.SUFFOLK DISTRICT �'`J,s. W I BRITTLE,JR � "-e' DIRECTOR OF ENGINEERING WILLIAM T ROBINSON WEST POINT FREDERICKSBURG DISTRICT J CARLTON CLORE CULPEPER CULPEPER DISTRICT OSCAR K MABRY JT� J� A�7�7� � DIRECTOR OF PLANNING H DELMER ROBINSON JR WINCHESTER.STAUNTON DISTRICT C®A/II fY./II ON �1.A/ INALTH of VIRGINIA H W WORRALL JAMES C.HUGHES.ANNANDALE AT LARGE URBAN l-1lL V'1L VV V'YY LLLLLL...eee LLL 111LLL �.I DIRECTOR OF FINANCIAL AFFAIRS CHARLES S HOOPER JR CREWE.AT LARGE RURAL DEPARTMENT OF HIGHWAYS & TRANSPORTATION '-1-2 1 C STfifi®7,te STTA LC IN REPLY PLEASE REFER TO P. 0. Box 910 Charlottesville, Va. 22902-0910 March 30, 1982 a Z ✓ Ms . N. Mason Caperton County Office Building 401 McIntire Road Charlottesville, Va. 22901-4596 Re: Site Plan Review Meeting April 1, 1982 Items 5-8 Dear Ms . Caperton: The following are our comments: 5 . Real Estate III, West, Office Building, "Z" Site Plan, Route 250 West: An adequate commercial entrance serves this site. 6 . McKinley, Final Plat, Route 635: The existing entrance has adequate site distance for a private entrance, however, if the residue were to develop further, the entrance location may not be adequate for a private street couuuercial entrance. 7 . 7-Eleven Store, Site Plan, Route 649 at 29 N. : The Route 29 corridor study as approved by the Board of Supervisors calls for a grade separated interchange, ul imately, at this Route 29 intersection. In order for this to be accomplished, on of the access ramps will go through this site. Accordingly, we cannot recommend ap royal of any plans which would prohibit implementation of the Route 29 improvement. Be ore commenting further on the previous restrictions placed on this property, na ,ely, access only through the existing entrance on the adjacent parcel, we must knew the County's intentions with regard to the Route 29 corridor study at this location. 8. John Bosely, Final Plat, Route 743: A modified private street entrance was issued at this location. A condition of that permit, however, was that it was to serve a maximum of three lots . This permit was obtained by Mr. Bosely. We cannot recommend approval of any further development or subdivision until a Standard entrance can be constructed. Approval of this subdivision request would invalidate the existing permit signed by Mr. Bosely. TQANICP/lRTATIFIN — AMPRIrLVC I IFFI INFS