Loading...
HomeMy WebLinkAboutARB202000016 Plan - Approved 2020-07-24874 RIO ROAD MINOR SITE PLAN AMENDMENT SDP202000005 ALBEMARLE COUNTY, VIRGINIA SCOPE OF WORK: THE WORK GENERALLY CONSISTS OF MINOR SITE WORK ASSOCIATED WITH A NEW OCCUPANT AT THIS LOCATION. SITE WORK INCLUDES: • PROVIDING EIGHT (8) SATELLITE DISHES • LANDSCAPE MATERIALS FOR SCREENING • NEW CURB LINES AND REVISIONS TO PARKING AREA • SECURITY FENCE AROUND SATELLITE DISHES • COMPLIANT LANDSCAPE PLAN PROJECT SUMMARY NAME OF PROJECT: LOCKWOOD BROADCASTING OFFICES+ PRODUCTION STUDIO PROJECT LOCATION: 874 RIO EAST COURT ALBEMARLE COUNTY, VIRGINIA DEVELOPMENT TYPE: REDEVELOPMENT/BY-RIGHT PREVIOUSLY APPROVED SITE PLANS: SDP1996-100 SDP1997-39 SDP1997-091 APPLICANT/OWNER ENGIN EER OF RECORD: SOURCE OF TOPOGRAPHY CONTACT: DAVEHANNAH JK INVESTMENTS, LLC ADDRESS: 220 SALTERS CREEK ROAD HAMPTON VA 23661 PHONE: - EMAIL: DHANNA@LOCKWOODBROAOCAST.COM CONTACT: LINE ANDGRADE CIVIL ENGINEERING DANIEL C. HYER, PE ADDRESS: 113 4TH STREET N E; STE 10D CHARLOTTESVILLE, VA 22902 PHONE: 434-262-0169 EMAIL: DHYER@LINE-GRADE.COM SOURCE: ACTUAL GROUND SURVEY (SEE SHEET XI.0 FOR SIGNED SURVEY) CONTACT: DRAPER ADEN AND ASSOCIATES CHERYLSTOCKTON ADDRESS: 110 AVON STREET CHARLOTTESVILLE, VA 22902 PHONE: 434-2950700 EMAIL: CSTOCKTON@DAA.COM TMP 61-124C ZMA ZMA-1996-00004 PARCEL I D: 06100-00-00-12400 ZONED: PLANNED DEVELOPMENT MIXED COMMERCIAL(PD-MC) OVERLAYS AIRPORT IMPACT; ENTRANCE CORRIDOR; STEEP SLOPES MANAGED LEGAL AREA: 1.21 ACRES 52,708 SF TOTAL LEGAL AREA: 3.21 ACRES MAGISTERIAL DISTRICT: RIO PROPOSED SITE PLAN REQUIREMENTS ALLOWED OR REQ'D BUILDING HEIGHT: PER 25A.6-> 21.4 MAX HEIGHT ALLOW ED = 6S FT EXISTING BUILDING HEIGHT= 14 FT PROPOSED BUILDING HEIGHT= (no proposed bulding height) 14 FT SETBACKS Per4.2D PRIMARY STREET (RIO EAST COURT) MIN FRONTYARD= 10 FT PRIMARY STREET (RIO EAST COURT) MAX FRONT YARD = NONE REQUIRED SECONDARY STREET (RIO ROAD EAST, ROUTE 631) MIN FRONT YARD = 10 FT SECONDARY STREET (RIO ROAD EAST, ROUTE 631) MAX FRONT YARD = NONE REQUIRED SIDE AND REAR (ADJACENTTO COMMERCIAL) = NONE REQUIRED SCREENING: ADJACENTTO COMMERCIAL NONE REQUIRED PER 32.7.9.7 SEE LANDSCAPE SHEETS FOR SPECI FIC SITE ELEMENTS TO BE SCREEN ED FROM PUBLIC STREETS EXISTING BUILDINGS EXISTING BUILDING 10,S48 SF EXISTING BUILDINGSTOTAL= 10,548 SF PROPOSED BUILDINGS PROPOSED BUILDING 0 SF PROPOSED BUILDINGS TOTAL = 0 SF OFFICE, GENERAL (G.F.A) OFFICE, GENERAL N. F.A = 0.8-G. F.A PARKING REQUIRED 10,S48 SF 8,438 OFFICE, GENERAL:1 SPACE PER 200 SF OF NFA 42 TOTAL REQUIRED PARKING= 42 SPACES PerADA Std. 208 HANDICAP SPACES REQUIRED= 2SPACES PARKING PROVIDED: OFFICE, GENERAL:1 SPACE PER 200SF OF NFA 0 TOTALREQUIRED PARKING= S8 SPACES PerADA Std. 208 HANDICAP SPACES REQUIRED 3SPACES TREE CANOPY COVER: SEE DSU PLAN ga > -130 � / �cn O [� J �_ PROJECT LOCATION. ] o Q Q ``J/ e (00 47 � Q o OD • p fJ v 0 , O Q �t= C:ZD oE-lp CP rj STANDARD ABBREVIATIONS ABAN ABANDON NIC NOT IN CONTRACT AC ACRES N.T.S. NOT TO SCALE ADJ ADJUST NB NORTHBOUND APPROX APPROXIMATE OC ON CENTER ASPH ASPHALT OD OUTSIDE DIAMETER Q BASELINE PRKG PARKING BLDG BUILDING PROJ PROJECT BM BENCHMARK PROP PROPOSED FL CENTERLINE PVMT PAVEMENT CF CUBIC FEET PM PAVEMENT MARKING CG CURB AND GUTTER REM REMOVE CONC CONCRETE ROW RIGHT-OF-WAY CONST CONSTRUCTION RT RIGHT DI DROP INLET R&D REMOVE AND DISPOSE DND DO NOT DISTURB R&R REMOVE AND RESET EB EASTBOUND R&S REMOVE AND STACK EL ELEVATION SB SOUTHBOUND EX EXISTING SF SQUARE FEET FIND FOUNDATION SSD STOPPING SIGHT DISTANCE GRVL GRAVEL STA STATION HC HANDICAP SW SIDEWALK ID INSIDE DIAMETER TEMP TEMPORARY LA LANDSCAPED AREA TRANS TRANSITION LF LINEAR FEET TYP TYPICAL LOD LIMITS OF DISTURBANCE WB WESTBOUND LT LEFT WSEL WATER SURFACE ELEVATION MAX MAXIMUM MIN MINIMUM ME MATCH EXISTING ALIGNMENT/GRADING ABBREVIATIONS w 0 Q Rl W z J ca Z E7C W Uj Z Z Uj BC BACK OF CURB PCC POINT OF COMPOUND CURVATURE BR BOTTOM OF RAMP PI POINT OF INTERSECTION BVCS BEGIN VERTICAL CURVE STATION PNT POINT BVCE BEGIN VERTICAL CURVE ELEVATION PR PROPOSED ELEVATION BW BOTTOM OF WALL PRC POINT OF REVERSE CURVATURE D OR A DELTA ANGLE PT POINT OF TANGENCY EG EXISTING GRADE PVC POINT OF VERTICAL CURVATURE EP EDGE OF PAVEMENT PVI POINT OF VERTICAL INTERSECTION EVCS END VERTICAL CURVE STATION PVT POINT OF VERTICAL TANGENCY EVCE END VERTICAL CURVE ELEVATION R RADIUS FG FINISHED GRADE TAN TANGENT DISTANCE FL FLOWLINE TC TOP OF CURB HP HIGH POINT THT THROAT INV INVERT TR TOP OF RAMP L LENGTH TW TOP OF WALL LP LOW POINT STA STATION LVC LENGTH OF VERTICAL CURVATURE SP SADDLE POINT PC POINT OF CURVATURE OFF OFFSET z Lli Q Q z SHEET LIST TABLE 0 w Sheet Number SHEET TITLE C)L Q z J CO.0 TITLE SHEET CO.1 GENERAL NOTES C) z O C0.2 ZMA APPROVAL J 0 LL CO.3 APPROVED SITE PLAN SDP199700091 J J C1.0 EXISTING CONDITIONS AND ESC AND DEMOLITION PLAN LU Q C1.1 DEMOLITION AND EROSION & SEDIMENT CONTROL DETAILS 7 W 0M0 W C2.0 SITE PLAN AMENDMENT m C2.1 SITE DETAILS O Q C2.2 SPECIFIC SITE DETAILS z C3.0 LANDSCAPE PLAN C3.1 PLANTING DETAILS C4.0 MATERIALS PLAN XO.0 TOPOGRAPHIC SURVEY 874 RIO E. CT. SUBMITTAL LOG SUBMISSION DESCRIPTION RECIPIENT SUBMITTAL DATE 1 1000/0 ALBEMARLE COUNTY 01/15/2020 COMMUNITY DEVELOPMENT 2 1000/0 ALBEMARLE COUNTY 03/27/2020 COMMUNITY DEVELOPMENT SIGNATURE PANEL: DEPARTMENT OF COMMUNITY DEVELOPMENT PLANNING & ZONING ENGINEERING INSPECTIONS ARCHITECTURAL REVIEW BOARD DEPARTMENT OF FIRE AND RESCUE ALBEMARLE COUNTY SERVICE AUTHORITY VIRGINIA DEPARTMENT OF TRANSPORTATION HEALTH DEPARTMENT APPROVAL DATE TH Op� 0020020 2� DANIEL C. HYER 9 LLC. No. 45596, !OVAL APPROVED DCH SUBMISSIONI Nl' 2 PROJECI 1910500 T H E W 0 R h u L I N E + G R A D E VICINITY MAP ;� LOCATION MAP N Approved for ARB 7/24/20 mmm SCALE: 1" = 20,000' �J SCALE: 1" = 500' C0.0 GENERAL CONSTRUCTION NOTES: UTILITIES: CONCRETE AND ASPHALT: 1. ALL CONSTRUCTION METHODS AND MATERIALS SHALL BE IN ACCORDANCE WITH THE CURRENT VIRGINIA DEPARTMENT OF TRANSPORTATION ROAD AND BRIDGE STANDARDS AND SPECIFICATIONS (VDOT RBS&S), VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK, THE RULES AND REGULATIONS WATER AND SANITARY SEWER CONSTRUCTION SPECIFICATIONS AND STANDARDS FOR THE PLAN APPROVING AUTHORITY AND ANY OTHER APPLICABLE FEDERAL, STATE, OR LOCAL ORDINANCES, CODES, AND LAWS. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL CONDITIONS, MATERIALS, DIMENSIONS LOCATIONS AND EXISTING ELEMENTS TO REMAIN IN THE FIELD BEFORE PROCEEDINGS WITH ANY WORK. IF CONDITIONS VARY FROM WHAT IS REPRESENTED IN THE DRAWINGS, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ENGINEER. 3. EXISTING CONSTRUCTION SHOWN IN THESE DRAWINGS SHALL BE USED AS RELATIVE REFERENCES AND ARE TO BE VERIFIED IN THE FIELD BY THE CONTRACTOR IF DEEMED CRITICAL FOR PROPER EXECUTION OF THE WORK. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DUST CONTROL MEASURES. 5. PROVIDE ADEQUATE PROTECTION FOR THE EXISTING BUILDINGS, BUILDING OCCUPANTS, VEHICLES AND PEDESTRIANS AT ALL TIMES IN ACCORDANCE WITH OSHA AND ALL APPLICABLE STATE AND LOCAL CODES. 6. MATERIALS AND EQUIPMENT SHALL BE STORED IN APPROVED AREAS TO PREVENT IMPACTS ON VEHICLES AND PEDESTRIANS. CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR MEASURES TAKEN TO ENSURE VEHICULAR AND PEDESTRIAN SAFETY THROUGH THE ENTIRE DURATION OF THE WORK. SAFETY IS PARAMOUNT. 7. EQUIPMENT AND MATERIALS SHALL BE STORED IN DESIGNATED AREAS AND SHALL NOT ENCUMBER THE OWNER'S OPERATIONS, SURROUNDING RIGHT OF WAY, OR ADJOINING GROUNDS. 8. ALL WORK AREAS SHALL BE CLEANED DAILY. 9. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF BUILDINGS ADJACENT TO WORK AREAS. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS OF DAMAGES RESULTING FROM CONSTRUCTION ACTIVITIES. 10. SECTION CUTS AND DETAIL CALLOUTS INDICATED IN THE DRAWINGS ARE TYPICAL FOR THE PROJECT. THEY ARE TO BE CONSIDERED TYPICAL FOR SIMILAR CONDITIONS AND HAVE NOT BEEN SHOWN EVERYWHERE THEY APPLY. 11. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR JOB SITE SAFETY. 12. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF ALL CONSTRUCTION. 13. SYMBOLS IN THE DRAWINGS ARE NOT TO SCALE. 14. ALL WORK SHALL BE LAID -OUT PRIOR TO INSTALLATION OF NEW WORK BASED ON MEASUREMENT OF EXISTING CONSTRUCTION AND EXISTING CONSTRUCTION DESIGNATED TO REMAIN AS PART OF THE PROJECT. DO NOT START INSTALLATION OF WORK UNTIL LAY -OUT IS COMPLETE AND. O. EN ... CONFLICTS HAVE BEEN IDENTIFIED AND ADDRESSED. 15. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ALL DAMAGE TO THE EXISTING BUILDINGS AND ADJACENT GROUNDS AND PROPERTY CAUSE BY THE CARELESSNESS OR NEGLECT OF HIS WORKMEN. DAMAGE TO PORTIONS OF THE PROPERTY NOT SUBJECT TO WORK UNDER THE CONTRACT SHALL BE REPAIRED TO THE FULL SATISFACTION OF THE OWNER AND ENGINEER, AT THE CONTRACTOR'S EXPENSE. 16. PROTECTION OF THE WORK: PROTECT EFFECTIVELY ALL MATERIALS AND EQUIPMENT DURING THE ENTIRE PERIOD OF CONSTRUCTION. REPLACE MATERIALS AND EQUIPMENT DAMAGED, LOST OR STOLEN WITHOUT ADDITIONAL COST TO THE OWNER. 17. PROTECT EXISTING MATERIALS DURING INSTALLATION OF TEMPORARY PROTECTION AND CONSTRUCTION. DO NOT DEFACE OR REMOVE EXISTING MATERIALS IF INTENDED TO STAY. ATTACHMENTS OF TEMPORARY PROTECTION TO EXISTING CONSTRUCTION SHALL BE APPROVED BY THE ENGINEER PRIOR TO INSTALLATION. 18. OBTAIN ENGINEER REVIEW AND WRITTEN APPROVAL IN THE FORM OF A CONSTRUCTION CHANGE DIRECTIVE OR SUPPLEMENTAL INSTRUCTION BEFORE MAKING CHANGES OR ADDITIONS TO CONSTRUCTION OR REMOVING MATERIALS THAT WERE INTENDED TO REMAIN. 19. NOTIFY ENGINEER OF VISIBLE CHANGES IN THE INTEGRITY OF MATERIALS OR COMPONENTS WHETHER DUE TO ENVIRONMENTAL CAUSES INCLUDING BIOLOGICAL ATTACK, UV DEGRADATION, FREEZING OR THAWING OR DUE TO STRUCTURAL DEFECTS INCLUDING CRACKS, MOVEMENT OR DISTORTION. DO NOT PROCEED WITH WORK IN QUESTION UNTIL DIRECTED BY THE ENGINEER. 20. WHERE MISSING FEATURES ARE INDICATED TO BE REPAIRED OR REPLACED, PROVIDE FEATURES WHOSE DESIGNS ARE BASED ON ACCURATE DUPLICATIONS RATHER THAN ON CONJECTURAL DESIGNS, SUBJECT TO APPROVAL OF THE ENGINEER. 21. WHERE WORK REQUIRES EXISTING FEATURES TO BE REMOVED, CLEANED AND REUSED, PERFORM THESE OPERATIONS WITHOUT DAMAGE TO THE MATERIALS THEMSELVES, TO ADJACENT MATERIALS, OR TO THE SUBSTRATE. WHEN CLEANING, MATCH SAMPLES OF EXISTING MATERIALS THAT HAVE BEEN CLEANED AND IDENTIFIED FOR ACCEPTABLE CLEANING LEVELS. AVOID OVER CLEANING TO PREVENT DAMAGE TO EXISTING MATERIALS DURING CLEANING. 22. TEMPORARY MATERIALS MAY BE NEW OR USED, BUT MUST BE ADEQUATE IN FOR REQUIRED USAGE, MUST NOT CREATE UNSAFE CONDITIONS AND MUST NOT VIOLATE REQUIREMENTS OF APPLICABLE CODES AND STANDARDS. 23. CONTRACTOR SHALL PROVIDE AND MAINTAIN ADEQUATE FIRE PROTECTION IN THE FORM OF FIRE EXTINGUISHER OR OTHER EFFECTIVE MEANS OF EXTINGUISHING FIRE, READY FOR INSTANT USE, DISTRIBUTED AROUND THE PROJECT AND IN AND ABOUT TEMPORARY, INFLAMMABLE STRUCTURES DURING CONSTRUCTION OF WORK. EXISTING FIRE HOSE CONNECTIONS SHALL BE ACCESSIBLE AT ALL TIMES BY FIRE DEPARTMENT PERSONNEL. MATERIAL SAND DEBRIS SHALL NOT BE STORED IN FRONT OF THE CONNECTION, THUS PREVENTING ACCESS. THE CONTRACTOR SHALL COORDINATE ACCESS PROCEDURES WITH THE FIRE MARSHALL. 24. GASOLINE AND OTHER FLAMMABLE LIQUIDS SHALL BE STORED AND DISPENSED FROM UL LISTED SAFETY CONTAINERS IN CONFORMANCE WITH THE NATIONAL BOARD OF FIRE UNDERWRITERS' RECOMMENDATIONS. 25. SUBMITTALS ARE NOT REQUIRED IF CONTRACTOR ELECTS TO USE THE PROPRIETARY PRODUCTS LISTED. SUBMITTALS WILL BE REQUIRED IF CONTRACTOR WISHES TO USE ALTERNATE PRODUCTS. ALL ALTERNATE PRODUCTS ARE SUBJECT TO REVIEW AND APPROVAL BY THE ENGINEER AND OWNER. 26. CONTRACTOR SHALL CALL MISS UTILITY AT 1-800-552-7001 BEFORE CONSTRUCTION COMMENCES. 27. TREE AND PLANT ROOTS OR BRANCHES THAT MAY INTERFERE WITH THE WORK SHALL BE TRIMMED OR CUT ONLY WITH THE APPROVAL OF THE OWNER AND ENGINEER. ANY TREES OR PLANTS WHICH ARE SHOWN TO REMAIN THAT DO NOT INTERFERE WITH THE WORK, BUT ARE DAMAGED BY CONTRACTOR OR HIS SUB -CONTRACTORS, SHALL BE REPLACED BY CONTRACTOR AT NO ADDITIONAL COST. WORK AREA PROTECTION AND MAINTENANCE: 1. CLEARING AND GRUBBING SHALL BE CONFINED TO THOSE AREAS NEEDED FOR CONSTRUCTION, AND AS SHOWN IN THE DRAWINGS. 2. DISTURBED AREAS BEYOND THE ROADWAY CURB AND WHERE INDICATED ON THE PLANS SHALL RECEIVE TOPSOIL AS NECESSARY AND AS DIRECTED. SEEDING MIXTURE SHALL BE DETERMINED BY THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK SECTION 3.32 3. CONTRACTOR IS PERMITTED TO WORK IN THE PUBLIC RIGHT-OF-WAY AND ANY TEMPORARY OR PERMANENT EASEMENT SHOWN ON THE PLANS. HOWEVER, CONTRACTOR SHALL NOTIFY PROPERTY OWNER(S) FORTY-EIGHT (48) HOURS PRIOR TO WORKING ON ANY PRIVATE PROPERTY TO COORDINATE ACCESS AND TO DETERMINE A STORAGE AREA FOR MATERIALS IF NEEDED. COORDINATION OF ACCESS TO PUBLIC RIGHT-OF-WAY AND STORAGE OF MATERIALS THEREON SHALL BE COORDINATED WITH THE ENGINEER. CONTRACTOR'S FAILURE TO NOTIFY AND COORDINATE WITH PROPERTY OWNERS AND/OR THE ENGINEER MAY RESULT IN DELAYS. NO ADDITIONAL COMPENSATION OR TIME FOR PERFORMANCE WILL BE GIVEN FOR ANY SUCH DELAYS. 4. CONTRACTOR SHALL, AT HIS EXPENSE, MAINTAIN THE WORK SITE IN A CLEAN AND ORDERLY APPEARANCE AT ALL TIMES. ALL DEBRIS AND SURPLUS MATERIAL COLLECTED SHALL BE DISPOSED OF OFF THE WORK SITE BY CONTRACTOR, AT HIS EXPENSE. 5. EXISTING LAWNS, TREES, SHRUBS, FENCES, UTILITIES, CULVERTS, WALLS, WALKS, DRIVEWAYS, POLES, SIGNS, RIGHT-OF-WAY MONUMENTS, MAILBOXES AND THE LIKE SHALL BE PROTECTED FROM DAMAGE DURING THE WORK. ANY DAMAGE CAUSED TO SUCH ITEMS SHALL BE REPAIRED OR REPLACED BY CONTRACTOR AT NO ADDITIONAL COST. PROPERTY PINS DISTURBED BY CONTRACTOR THAT ARE NOT SHOWN ON THE PLANS TO BE DISTURBED SHALL BE RESTORED BY LICENSED SURVEYOR AT THE CONTRACTOR'S EXPENSE. 6. MEASURES TO CONTROL EROSION AND SEDIMENT SHALL BE PROVIDED PURSUANT TO AND IN COMPLIANCE WITH CURRENT FEDERAL, STATE AND LOCAL REGULATIONS. THE INFORMATION CONTAINED IN THE CONSTRUCTION PLANS AND/OR APPROVAL OF THE PLANS SHALL IN NO WAY RELIEVE THE CONTRACTOR OR HIS AGENT OF ANY LEGAL RESPONSIBILITY WHICH MAY BE REQUIRED BY THE CODE OF VIRGINIA OR ANY ORDINANCE ENACTED BY THE COUNTY OF ALBEMARLE. CONTRACTOR SHALL PROVIDE THE NECESSARY DIVERSION DITCHES, DIKES, OR TEMPORARY CULVERTS REQUIRED TO PREVENT MUD AND DEBRIS FROM BEING WASHED ONTO THE STREETS OR ADJACENT PROPERTY. CONTRACTOR'S VEHICLES SHALL BE KEPT CLEAN TO PREVENT MUD OR DUST FROM BEING DEPOSITED ON STREETS. NO AREA SHALL BE LEFT DENUDED FOR MORE THAN SEVEN (7) CALENDAR DAYS. 7. CONTRACTOR SHALL CLEAN UP, RESTORE, SEED AND MAINTAIN ALL DISTURBED AREAS IMMEDIATELY UPON COMPLETION OF WORK. TOPSOIL SEED, FERTILIZER AND MULCH SHALL BE PLACED IN ACCORDANCE WITH COUNTY OF ALBEMARLE STANDARDS ON ALL DISTURBED AREAS. A PERMANENT STAND OF GRASS ADEQUATE TO PREVENT EROSION SHALL BE ESTABLISHED PRIOR TO FINAL ACCEPTANCE. ALL EROSION AND SEDIMENT CONTROLS SHALL BE REMOVED WITHIN 30 DAYS AFTER THE PROJECT IS STABILIZED. (MS-18) 8. FOR FURTHER REQUIREMENTS AND DETAILS OF TREE PRESERVATION, PLANTING, EROSION AND SEDIMENT CONTROL, REFER TO THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK. 9. AN EROSION AND SEDIMENT CONTROL CERTIFIED RESPONSIBLE LAND DISTURBER (CRLD) IS REQUIRED FOR ALL LAND DISTURBANCE ACTIVITIES. 10. THE CONTRACTOR SHALL PROPERLY INSTALL AND MAINTAIN EROSION AND SEDIMENT CONTROLS FOR THE LIFE OF THE PROJECT; AND ROUTINELY CHECK CONTROL DEVICES BEFORE, DURING AND AFTER STORM EVENTS. 1. PRIOR TO CONSTRUCTION OR EXCAVATION, THE CONTRACTOR SHALL ASSUME RESPONSIBILITY OF LOCATING ANY AND ALL UNDERGROUND UTILITIES (PUBLIC OR PRIVATE) THAT MAY EXIST WITHIN OR CROSS THROUGH THE AREA OF CONSTRUCTION WHETHER OR NOT THEY ARE SHOWN ON THE PLANS. PRIOR TO ANY CONSTRUCTION ACTIVITY, THE CONTRACTOR SHALL CALL 'MISS UTILITY OF VIRGINIA' AT 1-800-552-7001. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING, AT HIS SOLE EXPENSE, ANY EXISTING UTILITY DAMAGED DURING CONSTRUCTION. 2. THE PLAN DOES NOT GUARANTEE THE EXISTENCE, NONEXISTENCE, SIZE, TYPE, LOCATION, ALIGNMENT, OR DEPTH OF ANY OR ALL UNDERGROUND UTILITIES OR OTHER FACILITIES. WHERE SURFACE FEATURES (MANHOLES, CATCH BASINS, VALVES, ETC.) ARE UNAVAILABLE OR INCONCLUSIVE. INFORMATION SHOWN MAY BE FROM UTILITY OWNER'S RECORDS AND/OR ELECTRONIC LINE TRACING, THE RELIABILITY OF WHICH IS UNCERTAIN. THE CONTRACTOR SHALL PERFORM TEST EXCAVATIONS OR OTHER INVESTIGATION AS NECESSARY TO VERIFY LOCATION AND CLEARANCES. 3. WHEN THE WORK CROSSES EXISTING UTILITIES, THE EXISTING UTILITIES SHALL BE ADEQUATELY SUPPORTED AND PROTECTED FROM THE DAMAGE DUE TO THE WORK. ALL METHODS FOR SUPPORTING AND MAINTAINING THE EXISTING UTILITIES SHALL BE APPROVED BY THE RESPECTIVE UTILITY COMPANY AND/OR THE ENGINEER. CONTRACTOR SHALL EXERCISE CARE TO INSURE THAT THE GRADE AND ALIGNMENT OF EXISTING UTILITIES ARE MAINTAINED AND THAT NO JOINTS OR CONNECTIONS ARE DISPLACED. BACKFILL SHALL BE CAREFULLY PLACED AND COMPACTED TO PREVENT FUTURE DAMAGE OR SETTLEMENT TO EXISTING UTILITIES. ANY UTILITIES REMOVED AS PART OF THE WORK, AND NOT INDICATED TO BE REMOVED OR ABANDONED, SHALL BE RESTORED USING MATERIALS AND INSTALLATION EQUAL TO THE UTILITY'S STANDARDS. 4. CONTRACTOR SHALL NOTIFY LANDOWNERS TENANTS AND THE ENGINEER A MINIMUM OF 72 HOURS PRIOR TO THE INTERRUPTION OF ANY SERVICES. SERVICE INTERRUPTIONS SHALL BE KEPT TO A MINIMUM. 5. CONTRACTOR TO MAKE ANY NECESSARY ADJUSTMENTS TO ALL UTILITY JUNCTION BOXES, VALVE BOXES, MANHOLES, CLEAN -OUTS, AND OTHER GRADE RELATED ITEMS IN SIDEWALK, ROADWAY, AND/OR ADJACENT AREAS TO MATCH FINISHED GRADE. COSTS ARE TO BE INCLUDED UNDER THE VARIOUS UNIT BID ITEMS. NO SEPARATE PAYMENT WILL BE MADE. 6. PER THE VIRGINIA DEPARTMENT OF HEALTH WATERWORKS REGULATIONS (PART II, ARTICLE 3, SECTION 12 VAC 5-590 THROUGH 630), ALL BUILDINGS THAT HAVE THE POSSIBILITY OF CONTAMINATING THE POTABLE WATER DISTRIBUTION SYSTEM (HOSPITALS, INDUSTRIAL SITES, BREWERIES, ETC.) SHALL HAVE A BACKFLOW PREVENTION DEVICE INSTALLED WITHIN THE FACILITY. THIS DEVICE SHALL MEET SPECIFICATIONS OF THE VIRGINIA UNIFORM STATEWIDE BUILDING CODE, SHALL BE TESTED IN REGULAR INTERVALS AS REQUIRED, AND TEST RESULTS SHALL BE SUBMITTED TO THE REGULATORY COMPLIANCE ADMINISTRATOR IN THE DEPARTMENT OF UTILITIES. 7. ALL BUILDINGS THAT MAY PRODUCE WASTES CONTAINING MORE THAN ONE HUNDRED (100) PARTS PER MILLION OF FATS, OIL, OR GREASE SHALL INSTALL A GREASE TRAP. THE GREASE TRAP SHALL MEET SPECIFICATIONS OF THE VIRGINIA UNIFORM STATEWIDE BUILDING CODE, MAINTAIN RECORDS OF CLEANING AND MAINTENANCE, AND BE INSPECTED ON REGULAR INTERVALS BY THE REGULATORY COMPLIANCE ADMINISTRATOR IN THE DEPARTMENT OF UTILITIES. 8. CONTACT THE REGULATORY COMPLIANCE ADMINISTRATOR AT 970-3032 WITH ANY QUESTIONS REGARDING THE GREASE TRAP OR BACKFLOW PREVENTION DEVICES. 9. SATELLITE DISHES CAN ONLY RECEIVE TRANSMISSION SIGNALS. BROADCASTING IS NOT PERMITTED. EARTH WORK AND SITE CONDITIONS: 1. EXCEPT AS OTHERWISE SHOWN ON THE PLANS, ALL CUTS AND FILLS SHALL BE NO GREATER THAN 3:1. 2. UNLESS OTHERWISE NOTED ON THE PLANS OR IN THE SPECIFICATIONS, ALL FILL MATERIALS SHALL BE COMPACTED TO 95% OF THEORETICAL MAXIMUM DENSITY AS DETERMINED BY AASHTO T-99 METHOD A, WITHIN PLUS OR MINUS 2% OF OPTIMUM MOISTURE, FOR THE FULL WIDTH AND THE DEPTH OF THE FILL. 3. THE CONTRACTOR SHALL ADD, CHANGE, OR RELOCATE EROSION AND SEDIMENT CONTROLS AT THE DIRECTION OF THE COUNTY OF ALBEMARLE E&S INSPECTOR TO THEIR SATISFACTION AT NO ADDITIONAL COST TO THE OWNER. 4. ALL GRADING AND IMPROVEMENTS TO BE CONFINED TO THE PROJECT AREA UNLESS OTHERWISE INDICATED. 5. PROPOSED GRADES SHALL BE FIELD ADJUSTED TO CONFORM TO THE INTENT OF THE TYPICAL SECTIONS. A SMOOTH GRADE SHALL BE MAINTAINED FROM THE BASELINE TO THE PROPOSED EDGE OF PAVEMENT OR FACE OF CURB TO PRECLUDE THE FORMING OF FALSE GUTTERS AND/OR PONDING OF WATER ON ALL PAVED SURFACES. 6. CONTRACTOR SHALL MAINTAIN A SMOOTH GRADE TO THE PROPOSED EDGE OF PAVEMENT OR FACE OF CURB TO PROVIDE POSITIVE DRAINGE ON ALL PAVED SURFACES. ANY AREAS WHERE WATER IS IMPOUNDED SHALL BE CORRECTED BY CONTRACTOR AT NO ADDITIONAL COST. POSITIVE DRAINAGE OF ALL ROADWAY AREAS TO THE STORM DRAIN INLETS OR OTHER ACCEPTABLE DRAINAGE CHANNELS AS NOTED ON THE PLANS IS REQUIRED. 7. CONTRACTOR SHALL MAINTAIN EXISTING STREAMS, DITCHES, DRAINAGE STRUCTURES, CULVERT AND FLOWS AT ALL TIMES DURING THE WORK. CONTRACTOR SHALL PAY FOR ALL PERSONAL INJURY AND PROPERTY DAMAGE WHICH MAY OCCUR AS A RESULT OF FAILING TO MAINTAIN ADEQUATE DRAINAGE. 8. ALL PIPES, DI'S AND OTHER STRUCTURES SHALL BE INSPECTED BY THE ENGINEER BEFORE BEING BACKFILLED OR BURIED. THE ENGINEER MAY REQUIRE CONTRACTOR, AT NO ADDITIONAL COST, TO UNCOVER AND RE-COVER SUCH STRUCTURES IF THE HAVE BEEN BACKFILLED OR BURIED WITHOUT SUCH INSPECTION. 9. ALL STORM CHANNELS, DRAINS, AND SEWER SYSTEMS SHALL BE CLEANED UPON COMPLETION OF THE PROPOSED WORK. SEDIMENT, CHEMICALS, AND/OR DEBRIS REMOVED FROM THESE SYSTEMS SHALL BE REMOVED AND DISPOSED OF PROPERLY. MAINTENANCE OF TRAFFIC: 1. TEMPORARY STREET CLOSURE PERMIT REQUIRED FOR CLOSURE OF SIDEWALKS, PARKING SPACES AND ROADWAYS AND IS SUBJECT TO APPROVAL BY THE COUNTY OF ALBEMARLE TRAFFIC ENGINEER. 2. THE VIRGINIA WORK AREA PROTECTION MANUAL AND THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) SHALL GOVERN ALL TEMPORARY TRAFFIC CONTROL OPERATIONS THROUGHOUT CONSTRUCTION OF THIS PROJECT. ADHERENCE TO APPLICABLE PROVISIONS OF THE MANUAL IS REQUIRED OF THE CONTRACTOR EVEN THOUGH DETAILED REFERENCE TO ALL SUCH PROVISIONS MAY NOT BE CONTAINED IN THE PLANS. GENERAL NOTES 3. ALL EXISTING RESIDENTIAL AND COMMERCIAL ENTRANCES SHALL BE MAINTAINED AT ALL TIMES, UNLESS OTHERWISE DIRECTED BY THE ENGINEER. 4. NO TEMPORARY PAVEMENT MARKING SHALL BE ALLOWED ON THE FINAL ASPHALT SURFACE COURSE. 5. THE CONTRACTOR SHALL MAINTAIN ALL LANES OF TRAVEL OPEN FROM 6:30 AM TO 9:00 AM AND 3:00 PM TO 5:00 PM UNLESS DEEMED UNNECESSARY BY THE ENGINEER. SHORT PERIODS OF ONE WAY FLAGGING OPERATIONS MAY BE CONDUCTED OUTSIDE THE HOURS MENTIONED ABOVE. 6. ALL TRAFFIC SIGNALS SHALL BE ADJUSTED AS DEEMED NECESSARY BY THE ENGINEER PRIOR TO ANY TRAFFIC CHANGES. 7. WHEN WORK IN THE EXCAVATION AREA IS DISCONTINUED FOR A SHORT PERIOD OF TIME AS AT NIGHT THE CONTRACTOR SHALL BACKFILL THE CUT AREAS ADJACENT TO THE BUSTING PAVEMENT WITH A 'FILLET OF MATERIAL'. THE FILLET SHALL BE COMPOSED OF THE SAME MATERIAL (EXCAVATION, BORROW, BASE COURSE, ETC.) ALL COSTS FOR PLACING AND REMOVING THIS FILLET OF MATERIAL SHALL BE INCLUDED IN THE PRICE BID FOR OTHER BID ITEMS OF WORK ON THIS PROJECT, AND NO ADDITIONAL CHARGE WILL BE ALLOWED. 8. EXISTING SURFACE, AGGREGATE BASE AND SUBBASE MATERIAL WHICH WILL BE DEMOLISHED OR OBLITERATED DURING CONSTRUCTION AND WHICH IS SUITABLE FOR MAINTENANCE OF TRAFFIC AS DETERMINED BY THE ENGINEER, SHALL BE SALVAGED AND UTILIZED FOR MAINTENANCE OF TRAFFIC PRIOR TO THE USE OF COMMERCIAL MATERIAL. WHEN NOT SPECIFIED AS A SEPARATE PAY ITEM, THE REMOVAL AND SALVAGING OF EXISTING SURFACES AND AGGREGATE BASE AND SUBBASE MATERIAL WILL BE MEASURED AND PAID FOR AS REGULAR EXCAVATION IN ACCORDANCE WITH SECTION 303 OF THE VDOT ROAD AND BRIDGE SPECIFICATIONS. 9. CONSTRUCT ALL INTERSECTIONS AND DRIVEWAYS UNDER TRAFFIC. 10. IF USED, TEMPORARY TRAFFIC BARRIER SERVICE SHALL BE INSTALLED AND REMOVED SO AS NOT TO PRESENT ANY BLUNT END OR HAZARD TO THE MOTORING PUBLIC. 11. CONTRACTOR SHALL NOTIFY TRANSIT PROVIDERS A MINIMUM OF TWO WEEKS PRIOR TO ANY IMPACT OR DISRUPTION TO REGULAR SERVICE OR STOPS. 12. ALL EXISTING PAVEMENT MARKINGS CONFLICTING WITH PROPOSED CONSTRUCTION PAVEMENT MARKINGS (IF USED) SHALL BE ERADICATED. 13. INSTALLATION AND REMOVAL OF TEMPORARY TRAFFIC CONTROL DEVICES SHALL BE IN ACCORDANCE WITH THE SECTION 6G.25 OF THE WORK AREA PROTECTION MANUAL. 14. USE APPROPRIATE SIGNS TO SHIFT PEDESTRIAN TRAFFIC AS NEEDED. 15. CONTRACTOR SHALL ASSURE ENDS OF TEMPORARY CONCRETE BARRIER (IF USED) DO NOT OBSTRUCT INTERSECTION SIGHT LINES. FIRE PREVENTION: 1. SMOKING SHALL ONLY BE ALLOWED IN DESIGNATED SPACES WITH PROPER RECEPTACLES. "NO SMOKING" SIGNS SHALL BE POSTED AT EACH BUILDING SITE AND WITHIN EACH BUILDING DURING CONSTRUCTION PER VIRGINIA STATEWIDE FIRE PREVENTION CODE. 2. OVERHEAD WIRING OR OTHER OVERHEAD OBSTRUCTIONS SHALL NOT BE LOWER THAN 13 FEET 6 INCHES OVER A PUBLIC STREET PER THE VIRGINIA STATEWIDE FIRE PREVENTION CODE. 3. CONTRACTOR SHALL ENSURE THAT BUILDING STREET NUMBERS ARE PLAINLY VISIBLE FROM THE FRONTAGE STREET AT ALL TIMES DURING CONSTRUCTION FOR EMERGENCY RESPONDERS, PER VIRGINIA STATEWIDE FIRE PREVENTION CODE. 4. AN APPROVED WATER SUPPLY FOR FIRE PROTECTION SHALL BE MADE AVAILABLE AS SOON AS COMBUSTIBLE MATERIALS ARRIVE ON SITE. WASTE AND COMBUSTIBLE DEBRIS SHALL BE REMOVED FROM THE BUILDING AT THE END OF EACH DAY AND DISPOSED OF IN ACCORDANCE WITH VIRGINIA STATEWIDE FIRE PREVENTION CODE. 5. OPERATIONS INVOLVING THE USE OF CUTTING AND WELDING SHALL BE DONE IN ACCORDANCE WITH CHAPTER 35 OF THE VIRGINIA STATEWIDE FIRE PREVENTION CODE. 6. FIRE EXTINGUISHERS SHALL BE PROVIDED WITH NOT LESS THAN ONE APPROVED PORTABLE FIRE EXTINGUISHER AT EACH STAIRWAY ON ALL FLOOR LEVELS WHERE COMBUSTIBLE MATERIALS HAVE ACCUMULATED IN ACCORDANCE WITH THE VIRGINIA STATEWIDE FIRE PREVENTION CODE. 7. VEHICULAR ACCESS FOR FIRE FIGHTING SHALL BE PROVIDED AT ALL CONSTRUCTION AND DEMOLITION SITES AND TO WITHIN 100 FEET OF TEMPORARY OR PERMANENT FIRE DEPARTMENT CONNECTIONS. VEHICULAR ACCESS SHALL BE CAPABLE OF SUPPORTING FIRE APPARATUS AND VEHICLE LOADING UNDER ALL WEATHER CONDITIONS IN ACCORDANCE WITH THE VIRGINIA STATEWIDE FIRE PREVENTION CODE. 1. ALL MATERIAL INSIDE FORMS SHALL BE CLEAN AND FREE OF ALL ROCKS AND OTHER LOOSE DEBRIS. SUB -BASE MATERIAL SHALL BE COMPACTED BY MECHANICAL MEANS. 2. CONCRETE SHALL NOT BE PLACED UNLESS THE AIR TEMPERATURE IS AT LEAST 40 DEGREES FAHRENHEIT (F) IN THE SHADE AND RISING. 3. CONCRETE SHALL NOT BE PLACED UNTIL STEEL DOWELS HAVE BEEN INSTALLED IN EXISTING CONCRETE IN ACCORDANCE WITH COUNTY OF ALBEMARLE STANDARDS. 4. 1/2 " PREMOLDED EXPANSION JOINT MATERIAL SHALL BE PLACED AT A MAXIMUM OF 30' INTERVALS ON NEW SIDEWALK, CURB, CURB & GUTTER, AT EACH END OF DRIVEWAY ENTRANCES, AT EACH END OF HANDICAP RAMPS, SOME POINT ON ENTRANCE WALKS AND STEPS ADJUSTMENTS, AND ALONG BUILDINGS AND WALLS WHERE NEW CONCRETE SIDEWALKS ARE PLACED AGAINST THEM. 5. ALL EXISTING CURBS, CURB & GUTTER, SIDEWALK AND STEPS TO BE REMOVED SHALL BE TAKEN OUT TO THE NEAREST JOINT. DEMOLITION AND DISPOSAL COST TO BE INCLUDED IN OTHER UNIT BID ITEMS. NO SEPARATE PAYMENT WILL BE MADE FOR THIS WORK. 6. EXISTING ASPHALT CONCRETE PAVEMENT SHALL BE SAW CUT AND REMOVED AS PER THE SPECIFICATIONS. REMOVAL SHALL BE DONE IN SUCH A MANNER AS TO NOT TEAR, BULGE OR DISPLACE ADJACENT PAVEMENT. EDGES SHALL BE CLEAN AND VERTICAL, ALL CUTS SHALL BE PARALLEL OR PERPENDICULAR TO THE DIRECTION OF TRAFFIC. 7. DISPOSAL OF ALL EXCESS AND DEMOLITION MATERIAL IS THE RESPONSIBILITY OF THE CONTRACTOR. UTILITY INFORMATION: COMM.: COMCAST CENTURYLINK DOMINION VIRGINIA POWER LUMOS NETWORKS INC w 0 Q U WATER: RIVANNA WATER AND SEWER AUTHORITY uj STORM SEWER: ALBEMARLE COUNTY SERVICE AUTHORITY SANITARY SEWER: RIVANNA WATER AND SEWER AUTHORITY z WETLAND IMPACTS: NONE THIS SITE IS NOT LOCATED IN A WATER SUPPLY PROTECTION DISTRICT. SURFACE COVERAGE INFORMATION: PARCEL AREA: 1.21 AC (52867.2 SF) DISTURBANCE AREA: 0.18 AC (8,032 SF) EXISTING IMPERVIOUS AREA: 0.920 AC (40,060SF) PROPOSED IMPERVIOUS AREA: 0.822 AC (35,815 SF) PERCENT INCREASE IN IMPERVIOUS AREA:-10.5966% EXISTING PERVIOUS AREA: 0.293 AC (12,797 SF) PROPOSED PERVIOUS AREA: 0.391 AC (17,042 SF) 12 DIGIT HUC CODE: 0208-0204-0401 ADJACENT PROPERTY INFORMATION: 1. OWNER: SOVRAN BANK NA ZONING: HIGHWAY COMMERCIAL TAX MAP: 61; LOT 124E2 PARCEL:06100-00-00124E2 PRESENT USE: OFFICE (FINANCIAL) 2. OWNER: MAKIKA PROPERTIES LLC ZONING: HIGHWAY COMMERCIAL TAX MAP: 61; LOT 124E1 PARCEL: 06100-00-00-124E1 PRESENT USE: MINIATURE GOLF COURSE 3. OWNER: LINUS REALTY LLC ZONING: PLANNED DEVELOPMENT MIXED COMMERCIAL TAX MAP: 61; LOT 124B1 PARCEL: 06100-00-00124B1 PRESENT USE: OFFICE (LAW) h BENCHMARK "A" CHISELED SQUARE \ \ ELEV.: 521.84 O c- O 80.445 1 00 S150 52' 58.69"W 15' VEP 0 EASEMENT DB 15 PG 662 I \ I e o e O O o 2 BENCHMARK 1" = 10': 0 10 20 GENERAL SURVEY NOTES: TOPOGRAPHY SOURCE: ACTUAL GROUND SURVEY (SEE ATTACHED SURVEY) BASIS OF DATUM: HORIZONTAL: NAD-83 VIRGINIA SOUTH ZONE (GPS DERIVED) VERTICAL: NAVD-88 (GPS DERIVED) BENCHMARKS: (SEE IMAGES ABOVE) SUGGESTED CONSTRUCTION SEOUENCING: 1. PROTECT ADJACENT AREAS FROM DAMAGE DUE TO CONSTRUCTION ACTIVITIES. 2. INSTALL PERIMETER CONTROL MEASURES AS INDICATED ON PLANS INCLUDING SAFETY FENCE, SILT FENCE, AND TREE PROTECTION. 3. CLEAR AND GRUB EXISTING GROUND COVER AND DEMOLISH EXISTING ITEMS MARKED FOR DEMOLITION. 4. GRADE SITE TO FINAL GRADES PER PLANS. 5. FORM AND INSTALL CONCRETE WORK. 6. STABILIZE ALL AREAS AND REPAIR ANY EROSION AND REMOVE ANY SEDIMENT. 7. INSTALL REMAINING SITE FEATURES. 8. DRESS AND OVERSEED ALL DISTURBED AREAS AS NECESSARY TO AFFECT PERMANENT VEGETATIVE COVER. 9. REMOVE PERIMETER CONTROL MEASURES. mmi z LLJ 2i Q Z_ 0 C) � Q LLJ cl� O Q �zz 0 J O LLJ Ld ~ < 0 LLJ GO OJ Q z G TH Op� 0020020 2� DANIEL C. HYER 9 Lic. No. 45596• IOKAL APPROVED DCH SUBMISSION1 NIV 2 PROJECI 1910500 T HE W OR K u L IN E + G R AD E OVN-,;mil OF AL@,��q� ., DEPARTMENT of PLANNING and COMMI DEVELOPMENT 401 McIntire Road., ' Charlottesville, VA 229Gl'4596 804-296-5823 March '26, 1984 R• Di Trade Aui.lder, Incorporated 1495 East Rio Road Charlottesville, Virginia 22901 Re. ZMA-04�-6 -R. -D, Wade Builder, incorporated Dear Sim: The Albemarle- County Board of Supervisors, at its meeting Of March'210 1984, approved your above -referenced rezoning request; suh -ect to the two attached proffers. Therefore, the. 1:.16 acres contained in County Tax Map.61, part of Parcel 124C,.are rezoned from R7-10.Res.idential to CO Commercial. Office, zf you should have any questions concerning this action, please, contact Mr. Ronald S. Keeler, Chief of Planning Division,, at 296-5823, S3nce.tely, •hawk Stuaktt :B. Richard Depai:tment:. of Planning and Community Development s'lr Attachment a PL: NN94Gr ID BY.a' R.D.WADEBUILDER,INC. + 1495EASTRIOROAD • P.O:BOX1288 • CHARLOTTE,SVILLE.VA22902 (804)973-7841 - RD.WADEBUII,DER.INC. • 1495EASTRIOROAD • P.O.BOX1288 • CHARI.OTTESVII.LE;VA22902 • (804)973-7841 March 6, 198.4 Mr. Ronald S. Keeler Chief of Planning Department of Planning and Community.Development County of. Albemarle 401 McIntire Road Charlottesville, Virginia 22901 RE: ZMA-844 REZONING REQUEST Dear Mr. Keeler: I hereby agree that a financial institution, having 'a drive -up Window that would. generate'unusual traffic flow, maybe excluded as a "by right" usage of.subject property, if rezoniny.is granted. Yours truly, Randolph D. Wade President RDW/abc Doris B. 'Garrison RANDOLPH D. WADE Herbert T. Fischer General Manager - President: Property Manager Richard M. Slosson '►4 Charles T. Lebo Pmdnetion Manager _ 1 Sales Manager VIRGINIA REGISTERED CONTRACTOR NO-21013 March 6, 1984 Mr. Ronald S. Keeler Chief of Planning Department of Rlannina and Community Development County of Albemarle 401'Mclntire Road Charlottesville, Virginia 22901-4596 RE: ZMA-84-6 REZONING REQUEST Dear Mr. Keeler: The recommendation that the area proposed for rezoning be accessed .only From the proposed road that•is to serve the rest of the future development is perfectly acceptable to and desired by me. Yours truly, Randolph D. Wade President ROW/abc Doris B. Garrison General Manager Richard M. Slossaa Production Manager RANDOLPH D. WADE President - �°`�"�4! ..rt Herbert T. Fischer .. Property Manager Charles T.. Lebo - Sales. Manager . VIRGRUA REGISTERED CON1TI WTOR NO.21013 0 Z w 1N Z Z U W z J CZ G Q Z O/�2> Cr Q Z O Z Z:) J O LU LL1 � Q 00 Cn LU � m J OQ Z TH Op� 0312712020 'Z ( DANIEL C. HYER Iic. No.45596. '10NAL BX APPROVED DCH SUBMISSION NO. 2 PROJECT 1910500 T H E W 0 R K O F L I N E + G R A D E CO...2 STORM DRAINAGE STRUCTURES NO. TYPE L TOP INV. IN 1. DI-3A 2.5 516.0 2. DI-6B 6 618.61 613.0 2. 01-3A 2.3 516.60 610.0 4. DI-33 14 $13.66 508.66 1 ti � INV. OUT $14.0 812.90 509.9 E06.4E SCHEDULE OF LAND''SCAPE MATERIALS & CANOPY COMPUTATIONS •.,, Mor 6 r•a• r 24 f 2 KEY BOTANICAL 6 MIN. CALIPER TOTAL HEIGHT TOTAL WIDTH AREA OF QUANTITY TOTAL AREA 5, "on Bon* NA COMMON NAME IN 10 YEARS IN 10 YEAR$ CANOPY OF CANOPY Use Comm♦ re o 8a ne 1 ^� OXYDENDRUM ARBOREUM 1 1/4" 18.7' 13.2 138 S.F. 6 828 S.F. r. SOURWO.00 I SITE BENCHMAR K S Mark on concrete at hole CE RC IS CANADENSIS 1 1/4" 24 225 396 5F 6 2376 S.F. / no 11 putt putt golf course r EASTERN REDBUD % Elev 521 60 ✓ First floor of Sovran Bank CrRNUS FLORI DA 1 1/4 I9' 14 l 155 S F. 4 620 SF Elev 52067 } FLOWERING DOGWOOD U S G S Datu m `L QUERCUS PHELLOS 1 3/431 22 3 80S.F. 5 1900 S.F. WILLOW OAK I L E x CORNUTA IB-308 7. 8' 48 S. F. 45 2 1 6 0 `/- O B U F O R D H O L L Y _��.--•-r!r T. M. 61 Parcel /24 £/ Wow, L F Zonr n4 H C _- / / lg" E / ' NOTE : STREET TREES SHOWN ON EAST SIDE OF RID N 27017'18'E use Mifild' Lre Golf Co..ler 1 N18a32 �J' EAST COURT ARE FOR LONG RANGE PLANNING 3 D / PURPOSES ONLY AND ARE NOT A PART OF THIS SITE PLAN. �- 3 F• _ a - --- — /� _•�� Exist Drive woy to be removed d e/ t !. t 7•r _ . r •etc^/ ` \\ !l / I— 24 ! �/ - T 2 Loading Spaces - Uumns•er\\: 1 I JI % i t :Light Pole / / T - ..y r'aa ;. •♦♦news .. \ Light 9 i // /2 * 25 \ n.pr Sotr4 j Pole I I p ~ 4R , Tel Line s /lam T / / . + t r u .•, y / sr 7 t_ en, e O ;/r7 I l hry / tmoved - / \ c O o bV be to// ,re v n 3 5 �~ /• I /, / 0 r. /tt r • / 1 / Ilk I e \ h r23R/' /W / • n / i f \ Bldg' Light o e ! / O • 5er rice Boy E*,sr r•t • \1 1 - ` re ' emo wert e / q v 4, O / 4 / o I r / 5 R/ t• o r / h It It 110, 0 / BId9 I Service Bop, h / Etlst / oved11 o It 5,R ry ,.p / -- - - / / _ �.� % be rem / r r. t y,P -- �4 / 10 I ��a iae / .r Jr,. CG.t2 .01 // f / '/ / oA \J soar-z e V Y/ 3 Spors I l I / r t Light / 5 P„ , / �. e520 l /r 5 R eedl POrlmenl Motl r,�,//" �i� t�Or1+IOOt eb /`• �, / / / m • I h \s / 5•R .M n I Yp Bose �Ynrer, of ry \` E1 De /�' h I �/ / / b A /65 rbs Trpe SM2A Asphp/I `j _ L fa r „ i' / / / \x / / / // i/ // �0 % 519 . / / 5 3'R ---- I / �� \ I R t ' I /'�' 5,�� •'� 30 8ui/din Setback Liner__ r r._- / —r 1 - i I 1 ,�l 1_ 20 San. - Sewer £asytnenl /3. 34 1 t 1 J5 r-s 21 l s 1 1 � / .iR / - �� �g23oOj 42 E /III S o c e s t)L \ 11 1 `\ �P I / I r / / // 8 �P VC S a n. �S offer See Road Plan B Profile p ^/ Spaeet 9 e1/8'(t For Continuation r 4 C aDh! \ \ I `yhr \\ Po h ire, elt� (` �V[' //i A i / �186 % 4 84 lroJJVe r-4 p•p .- IrB ,_-- P •wteir+•o/�n�'a ati \ I % / / iva '9CPS ' roi _Wale, 'R P 156 � • t • Iar ee R / .i.�i �- • '!',...� i, {'. ,' :.�: . il,. t. i•-... :J'': ,'' ';i�-. t, CG /I £orient♦ ` i .` ::'/i -C4-./ \ I cG.., ; \ \,..:j: /./. /%.: /... ���U�/L�TY PLANS"FORREFER TO THE IAL/NAL L ROAD 8 / / / _ _ ' '� 'Z Z75 •to i \ \, \\ \ \ \ \ \ \ I // / CONSTRUCT/ON DETAILS. / /�JOo._„ \ \ \ R'/ \EAST i/C/ OU, T 4 \ \ \ \ h 4 \ \ \ \ \ \\ \ \ \ ` l 18"RCP a 3 0 ` \ \ j\ \ \ \\ \ \ \ \ \ \ �T \ 202 '&3. 02 % A i �- �i�,,.• �! -- - -----,-�-- ,., ' .' � • ace Road P/an B Prof / e v ' / t__ l •, - \ 4. \ For Continuation Fire_ - - - +-\ .•• �' le "RCP Pipe io be bu%kneaded so they, con\ \?��• y /� / r.4.' -'Hydron / S`(� 8' /.O% \ 1 I \ C \ (Fr\be opened toter \ \ \ \ W\ter/in \ \ \ \ \ \ \ \ \ \ \ \ \ oc. - h' ✓ \ Errs Bldg \ 20'WI de\ WaI0r\/rOf E0\0 m� n t\ \ \ \\ \ \ \ \ \\ \ \ \ \ mars \\ \ \ I \ \ CROSS SEC T / O N - R10 EAST COU R T 0 /' 'Exist Driveway 530 / to be removed 833, \ter r 1`I \ \ o \ \ \ \ 6' 6" walk Class A a slob e, I/4 •'per ft � \\ \` \` \` \ S I T E PLAN AMEN D M ENT \ \ '� Concrete \ 1 2" \Lt� \ j2R LIGHT POLE LOCATION /� � ��'r'+•`-".•`•'--��t;„-�. 'r� -e Top of finished To.r Mop 6/ Porce/ /24 A �n• �Da VIng slope s \ Compacted fill or :t undisturbed eortIt 8 T Y P I C A L S E C T 1 0 N S I D E W A L K Encore Investors Ltd Par In er s nip Z o n, n p C O Use Re s,d en t,o/ PLAN PREPARED MY: B. AUBREY HUFFMAN & ASSOCIATES, LTD. CIVIL ENGINEERING - LAND SURVEYING - LAND PLANNING CHARLOTTESVILLE VIRGINIA APPROVED SITE PLAN SDP199700091 C031 PLAN SCALE / "- 20 • C V C C T AI T1 01 w 0 Q iI I I // / / / / \ \ \ 1 DEMO AND ESC LEGEND L.L ' T. M. 6/ PARCEL /24El ` 1 (S SAFETY FENCE / 4 / T. M. 6/ PARCEL /24E2 MAKIKA PROt'ET TR/ES, LLC \ l SO BANK N A I I TP TREE PROTECTION ZONING • HC \ I ZONING: HC / USE: MINIA TURF GOLF USE: COMMERC/AL BAND( COURSE I I L✓ LIMITS OF DISTURBANCE 30" OqK CURB INLET PROTECTION 0 � S 12'5148"W 23.00' — — CHAINLINK y LIMITS SURVE �� SAWCUT _ FENC p� REMOVE AND RELOCATELu / / 0 S21 °3633"W 270.2T o o f "_ EX. DUMPSTER AREA LIMITS OF GENERAL DEMOLITION SEE PROPOSED PLAN E SAF 332 LF / �pC 36 LIMITS OF PAVEMENT PATCH O / I REMOVE EXISTING AS WAL BW.52. 06 - -- LOD �'�}� x / I / PAVING AND REPLACE WITH L����.1 _�� I TW.-5/9.49 X —�l_�1'F �.'�'T REMOVE TREE PROPOSED GROUND COVER N BW.�S/7 09 \\� — PERMANENT SEEDING ON ALL DISTURBED AREAS I l T.M. 6/ PARCEL /24 C ° / JKINVESTMENTSLLC PROTECT EXISTING l ZONING: PDMC BUILDING USE- OFFICES; NEWS STA T/ON a T. M. 6/ PARCEL /24B/ / OB 4563 PG 344 y EXISTING LIGHT l LINUS REAL TY LLC /l OB /57/ PG 562-566 TO BE REMOVED - REMOVE EX. TREES ZONING: PDMC l -=� LOD USE. LAW OFFICES OB /554 PG /75—/77 --� i' I / ONCRETEAT l_o i9OOR'521.95 ��b1, ' LOD I I� / h APPROXIMATE LOCATION OF RWSA /\ 18" Cl WATERLINEAND EASEMENT, REFER TO DB 2744 PG 413 L=971.64, R=3f3.62 �A S 17°23'1 I � \ \DEMOLITION AND EROSION AND SEDIMENT CONTROL PLAN 1" = 20': 0 20 40 TOP.�S/7.53 INV. /N.•5/0.96 INV. /N.�S/4.00 INV. /N.•5/0.9 DEMOLISH EX. CURBVV. OUT• 0.J S—tlUiLl Ear � OF i"ELSiRVCiuPES (SEE NOiE II) I Yv: oia. va URB BOX DUMPS ER PAD h SAN/TA 8,-P /7ANHOL - -- --------------- / /N. g,//.09 / V l 0 OAK T.-5/0.65 s, P CURB BOX OP.•5/4.86 NV //V.509.62 SE N . /N509.64 NW /�/ n//T•S/)O may; /I LLJ 2 Q Z_ 0 � � Q LLJ Q H zz O � J O Lu �LLJ M~< W Lu m OJ Q z ta Z uj uj z Z uj Q 0 0 LLJ U LLJ z 0 z 0 U C� z X Lu TH Op� 03� 0020 2� DANIEL C. HYER 9 Lic. N0. 45596, IOKAL APPROVED DCH SUBMISSION1 Ni' 2 PROJECI 1910500 T HE W OR K u L IN E + G R AD E -018-LINE+GRADE, LLC TABLE 3.31-B W t7 6'-0" MAX. SPACING (REVISED JUNE 2003) Z OF 2x4 SPACERS TEMPORARY SEEDING SPECIFICATIONS _ SAFETY FENCE QUICK REFERENCE FOR ALL REGIONS Q tL ISOMETRIC UJ ` z ��. ..� VDOT // 2x4 15 ® AGGREGATE ANCHOR ■�� ��� UJ 1 /J O 1 o TABLE 3.32-D FILTER FABRIC (REVISED JUNE 2003) Al t`?':i. _.,- " .'' c'' =" PERMANENT SEEDING SPECIFICATIONS FOR PIEDMONT AREA ..:.., ,::.:r:r=:':;•.:...........< :. -... .... ,._ .:.:....:.. ,.:,: WIRE MESH 2x4 WEIR 2x4 SPACER SAND BAG OR PERSPECTIVE VIEW ALTERNATE WEIGHT 2" ASPHALTIC CONCRETE,— VDOT SM-9.5, SURFACE COURSE 2'-0" MIN. LENGTH SAW CUT 2' FROM OF 2x4 FACE OF CURB r•; .,aM [fib a n»- STD. — �. FILTER CLOTH _ 2"X4"WEIR VDOT AGGREGATE ND.1� i r /^, '0 2x4 SPACER \/ / / \ \O / 6 WIRE MESH 6" DENSE GRADED �^�^ ✓ pL.�r / (SAME AS FOR AGGREGATE BASE / / O \\ wr>cx To '!!' "� ,p "Al\\ \ \ ° SILT FENCE O O \ W Wral I, \ \ \ ) COURSE, VDOT 21A YET.L W w/SS.i •='� EROU10 11E O/ 5' MIN. H MAX N \\/�\\�/ NLETTOPIPE 0 PERSPECTIVE VIEW PERSPECTIVE VIEW \/\\/\\ COMPACTED J PLASTIC FENCE METAL FENCE O SECTION \\\\\ SUBGRADE BASE AGGREGATE N Source: Adapted from Conwed Plastics and Plate 3.01-1 VDOT Road and Bridge Standards O 1 3.01-1 SAFETY FENCE 2 CURB INLET PROTECTION 3 MINIMUM PAVEMENT PATCH 4 SEEDING SCHEDULES w O O O O �¢ z oo� w zF5 2i 02 0 �z� n O Jo 06 a- LU �wE z ��< O moo¢ Cl) z_ w 0 z Q z O F_ J O 2 W 0 TH Op DJ�� 0 ql?212020 2 D DANIEL C. HYER 9 LIC. No. 45596 A �1ONAL BNd` APPROVED DCH SUBMISSION NO. 2 PROJECT 1910500 T H E W 0 R K O F L I N E + G R A D E C 1.1 APPLICATION SPECIES APPLICATION RATES 50/50 Mix of Annual Ryegrass Sept 1-Feb. 15 (Lolium mufti-florum)&Ce2al 54100 (Ibs/acre) (Winter) Rye (Secak create) Feb. 16-Apr. 30 Annual Ryegmss (lolium mufti-florum) 64100 (Ibs/acre) May1-Aug. 31 German Millet 50 (Ibs/acm) FERTILIZER &LIME Apply 1430-10 Fertilizer at a rate of 450 Ibs/acre (or 10 Ins. / 1,000 sq. R) Apply Pulverized Agricultural Limestone at a rate of 2 tons/acre (or 90 Ibs. / 1,000 sq. ft.) NOTE: 1. A soil test is necessa SEED' LAND USE SPECIES APPLICATION RATES PER ACRE Tall Fescuer 95300% Minimum Care Lawn —Residential) Perennial Ryegmss 0-5% (Commercial or Kentucky Bluegmssi 0-5% Total: vs2ooTbs High�daintenance Lawn Tall Fescue' Total 200-2501bs. Tall Fescuei 1281bs. General Slope (3:1 or less) Red Top Grass of Creeping Red Fescue Seasonal Nurse Cmp 21bs. 201bs. Total: 1501bs. Tall rescue SOH Ins. n L=971.64, R=313.62 C4 S 17°23'; i G2 SITE PLAN AMENDMENT 1" = 20': 0 20 40 6/ PARCEL /24E2 7VRAN BANK N A ZONING: HC COMMERCIAL BANK T. M. 6/ PARCEL /24El I MAKIKA PROPERTR/ES, L L C I ZONING • HC USE: MINIA TURF GOLF I COURSE \ _IS 1205148"W 23.00'� CHAINLINK SURVEY LIMIT F BURIED 4" DIAMETER CONDUIT 5 0 0 36 SCHEDULE 80 PVC (TYP) li i T.M. 6/ PARCEL I24B/ L INUS REAL TY LL C ZONING: PDI'-IC USE LAW OFFICES - SEE DETAIL 1/C2.2 FOR SATELLITE FOUNDATION SPACING I - SATELLITE FOUNDATION (SEE DETAIL 1/C2.2) SECURITY I NCE PERIMETER LENGTH 266 LINEAR FEET SEE DETAIL 8/C2.1 SLIDING SECURITY GATE J URB BOX TOP.-5/7.53 R /NV. /N•5/0. 96 5 IV. /N.-5/4.00 S INV. /N/./S/0.9 20' ACSA SAN ARY SEWER /' V.. OUT. 0.77 All ENT PROPOSED REFUSE DUMPSTER WITH ENCLOSURE (SEE DETAIL 3/C2.2) O CURB BOX \ nP.514.86 /NV //V.•509. 62 SE /N . /1V•509.64 NW � /I � �r � / �7//T•S/)O may; SHEET NOTES: 1. SATELLITE DISHES CAN ONLY RECEIVE TRANSMISSION SIGNALS. BROADCASTING IS NOT PERMITTED. uj ta Z uj z z uj ca W z J F- w z 2Q W Z Z_ C Q W 0 O �zz Q LZLJ � _0 J O 0- LLI z H < J 00 LLI 0 m Q W z � TH Op--vt 000020 2� DANIEL C. HYER 9 Lic. N0. 45596, IOKAL APPROVED DCH SUBMISSION1 N1' 2 PROJECI 1910500 T H E W 0 R h u L I N E + G R A D E C200 B A PERMISSIBLE CONSTRUCTION # 8" LONG o 12" C-C W®-■,� B RANSITION GUTTER PAN SLOPE A TO 20:1 THROUGH RAMP LENGTH TRANSITION GUTTER PAN SLOPE GUTTER PAN MAXIMUM SLOPE 20:1 TO 20:1 THROUGH RAMP LENGTH 8'-0" Min. 4'-0" Min. BACK OF CURB 12`1 MAX. 48:1 MAX. 20: 1 2'MIN. SECTION A -A SECTION B-B NOTES: 1. FOR GENERAL NOTES ON THE DETECTABLE WARNING SURFACE, SEE SHEET 1OF 5. 2. THIS DESIGN TO BE USED FOR CONSTRUCTION THAT INCORPORATES WIDER SIDEWALK. LANDING (4' WIDE) REOUIRED AT TOP OF CURB RAMP. MINIMUM CURB RAMP LENGTH 8 FEET FOR NEW CONSTRUCTION. 3. GUTTER PAN SHALL BE A MAXIMUM SLOPE OF 20:1 AT THE RAMP OPENING. 4. DIAGONAL PLACEMENT IS NOT PERMITTED. TYPICAL DESIGN =u= Sul _ 1 -Th_ n'nnTiop< 'irii=Tl5i=u7` TYPE A WITH BUFFER STRIP EXAMPLE INSTALLATION METHODS - SEE PLANS FOR LAYOUT CC-12 II II TYPICAL PLACEMENT TYPICAL PLACEMENT AT INTERSECTION AT INTERSECTION WITHIN CROSSWALK WITHIN CROSSWALK (WITH BUFFER STRIP) SPECIFICATION A COPY OF THE ORIDETECTABLEDRAWARNINGN TSUERFACE XVDOT REFERENCE �`�` 12 ROAD AND BRIDGE STANDARDS 105 TYPE A (PERPENDICULAR) APPLICATION REVISION DATE SHEET 2 OF 5 502 504 VIRGINIA DEPARTMENT OF TRANSPORTATION 04/19 1 204.02 ill \�/IIIC f1/.II.ITCII'I']IPE J 1\ TYPICAL PARKING SPACE RIGID SURFACE FINISHED GRADE (WHERE APPLICABLE, SEE NOTE 1 BELOW) 5' (UNLESS OTHERWISE NOTED) F- 2% CROSS SLOPE (SLOPED TO DRAIN) 1= _ I III I -III -II 6" X 6" W2.9 X W2.9 W.W.F. CENTERED IN CONCRETE ril MIN. 4" THICK, 3000 PSI CONCRETEII-II I IIIIIII10 I -IIII 1I-I 4" VDOT 21A STONE BASE =I- JOINT FILLER NOTE: 1. WHERE SIDEWALK ABUTS PAVEMENT, CONCRETE, CURB, BUILDING, OR OTHER HARD SURFACE, CONTRACTOR TO PROVIDE PRE -MOLDED JOINT FILLER AND EXPANSION JOINT AS SHOWN ABOVE. OCG-12A O SIDEWALK HANDICAP PARKING SYMBOL HANDICAP PARKING SIGN IVEMENT EDGE 1' RESERVED PARKING N PENALTY $100$500 FINE TOWAWAYZONE En VAN o ACCESSIBLE VAN PLACARD 5' MIN. TO (WHERE APPLICABLE) FINISHED GRADE HANDICAP PARKING SIGN PAHANDICAP RKING SIGN_ �- ADA PATH � 8 5 EE PLAN 81-4— 8'-4— 8' -1 SINGLE HANDICAP SPACE ZJACENT SPACES OR VAN S HANDICAP PARKING SPACE NOTES: 1. SPACES SHALL BE COMPLIANT WITH ADAAG 502.6 AND VUSBC 1106.8. 2. ALL HANDICAP PARKING PAVEMENT MARKINGS SHALL BE WHITE IN COLOR. HANDICAP PARKING SIGN NOTES: 3. SIGN SYMBOL SHALL BE INTERNATIONAL HANDICAP SYMBOL. 4. SIGN MATERIAL TO BE 0.065" ALUMINUM SHEET. 5. VAN PLACARD SHALL ONLY BE INSTALLED WHERE DESIGNATED ON PLANS. HANDICAP PARKING SPACE DETAILS 0 3" VDOT BM-25A ASPHALT CONIC. BASE OVER PRIME COAT PRIME COAT] 2" VDOT SM-9.A BIT. CONC. r-TACK COAT COMPACTED SUBGRADEJ L-8" VDOT 21A/21B, TYPE 1 AGGREGATE BASE ISUBGRADE STABILIZATION GEOTEXTILE FULL -DEPTH PAVEMENT SECTION O 7.1 1" ROUNDING OF CONCRETE SLOPE TO DRAIN i NOTES) 1. THIS ITEM MAY BE PRECAST OR CAST IN PLACE. 2. CONCRETE TO BE CLASS A3 IF CAST IN PLACE, 4000 PSI IF PRECAST. 3. CURB HAVING A RADIUS OF 300 FEET OR LESS (ALONG FACE OF CURB) WILL BE PAID FOR AS RADIAL CURB. 4• THE DEPTH OF CURB MAY BE REDUCED AS MUCH AS 3" (15" DEPTH) OR INCREASED AS MUCH AS 3" (21" DEPTH)IN ORDER THAT THE BOTTOM OF CURB WILL COINCIDE WITH THE TOP OF A COURSE OF THE PAVEMENT SUBSTRUCTURE. OTHERWISE, THE DEPTH IS TO BE IS" AS SHOWN. a NO ADJUSTMENT IN THE PRICE BID IS TO BE MADE FOR A DECREASE OR AN INCREASE IN DEPTH. o 5. CG-2 IS TO BE USED ON ROADWAYS MEETING z THE REQUIREMENTS FOR CG-6 AS SHOWN IN w APPENDIX A OF THE VDOT ROAD DESIGN MANUAL, Iwn IN THE SECTION ON GS URBAN STANDARDS. RADIUS D. o F ;. D.; • D. SURFI e•, ; ,;e•. BASE —SU�BBI s" I ACCEPTABLE ALTERNATIVE IF CURB IS EXTRUDED '10ENCE STANDARD 6" CURB 105 502 VIRGINIA DEPARTMENT OF TRANSPORTATION 0 CG-2 6" x 7'-6" LONG SCHEDULE 80 STEEL PIPE FILLED WITH CONCRETE. HOT DIPPED GALVANIZED AND PAINTED BLACK. PROVIDE POSTS AS INDICATED ON PLAN. 1.5' DIA. TYPE I BOLLARD POURED CONCRETE (3,500 P.S.I.) EXPANSION JOINT (TYP) #5 BAR, 12" LONG THROUGH PIPE O 4" R CG-2 SURFACE BASE SUBBASE ROAD AND BRIDGE STANDARDS REVISION DATE SHEET 1 OF 1 201.01 a. 4 o - ..a d; a v G a p Q: e � SPECIFICATION: HORTZ.ONTAI. BARS:1 1/2'*1 1%2'*16 GA GALVANTZ.F.D STEEL VERTICAL BARS:3/4'*3/4'*18GA SA. GALVANIZED STEEL 'TUBE POST:2'*2'*96'*16GA SQ.GALVANIZED STEEL TUBE FINISH:ELECTROPHORETIC COATING (POWDER COATED) SECURITY FENCE W z J w¢ oz Oz� o2 > QrQ�7_ Z O z � J O LL1 LL.I c� G U) LLJ LL m J C Q z ta z✓ ii W uj jZ V Z uj Q uj 0 LLJ ►:lI TH Op� 03�271?020 Z DANIEL C. HYER Y LIC. N0. 45596„ ZIONAL SN APPROVED DCH SUBMISSION NO. 2 PROJECT 1910500 T H E W 0 R K O F L I N E + G R A D E C2ml O.D. 6 5/8" O.D. PIPE RADE JTI-TWIST [BAR 5'MIN. 13'� 6' I SECTION A - A ANTI -TWIST REBAR 5/8" DIAM. X 18" NOTES 1. STEEL MAST PIPE: 6" SCHEDULE 80, L=156 6 5/8" O.D. 2. CONCRETE: 3000 PSI AT 28 DAYS, POURED AGAINST UNDISTURBED SOIL (ALLOW CONCRETE 24 HOUR SET TIME BEFORE INSTALLATION OF ANTENNA) 3. SOIL BEARING CAPACITY > 2000 PSF. 31 4. GROUND THE ANTENNA TO MEET I� APPLICABLE LOCAL CODES. IN -GROUND MAST FOUNDATION R643 [25.31 R618 [24.3] DOOR SWING _ DOOR SWING TYP — TYP 350 [13.811 ENCLOSED B EXHAUST OUTLET 507 [20.0] AIR INTAKE AIR INTAKE ENCLOSED BOTH SIDES BOTH SIDES EXHAUST OUTLET 3923 [154.41 OVERALL LENGTH RADIATOR/EXHAUST 3277 [129.0 DISCHARGE AIR AIR INTAKE BOTH SIDES 2059 [81.1] Il 241 [9.5] R a A DIM X C.O.G. 111 653 [25.7] Q 3250 (128.0 U 1/1 1 REV A WINDCHILL VERSION A.1 AIR INTME AIR INTAKE DIM Y C.O.G. L11:71k'1109d FOR ALL STUB -UP, WEIGHT, AND C.O.G. DETAILS, SEE CORRESPONDING OPEN SET DRAWING PER UNIT CONFIGURATION 1371 [54.0] OVERALL WIDTH f DIM Z C.O.G. 1234 [48.61 2128 [83.81 L3/U [93.3] OVERALL HEIGHT TITLE DRAWING CREATED FROM PRO/ENGINEER DIMENSIONS ARE IN MILLIMETERS [INCHES] L2A ENCLOSURE 3D FILE. ECO MODIFICATION TO BE APPLIED TO SOLID MODEL ONLY. 314.2L 60HZ: SG150/PG135, SG175/PG158, SG200/PG180 POWER SYSTEM O�S WE CO� OF WE DRNSNG „mom SPP EO NCONFIOENCEAN M BEUBEOFOR 50HZ: SG120/PG108 SG140/PG126 SG160/PG144 o���Q��lQ�ao� oc��a�a�c� ANYPURPJSEOTNRTRW pRMOR88UPNEDWRKK! WE ENPREBBNWTIENCONBF OFBENERACMVERBVaIEEB. ISSUE DATE: 11/26/14 � ®oEra:RAcvavERavaiENe mla ELECTRONICALLY APPROVED sIBZE CAGE NO DWG NO OL0467C REV INSIDE WINDCHILL SCALE 0.030 1 V1,i ISHEET 1 Of 1 4 3 2 1 GENERATOR SPECIFICATIONS 0 0 r. r. 12' 6' 6' 1.5' 3' 3' 31.5' a a G p 9 4 J p 4 � p. 4 a p (4) 6" 0 BOLLARDS ° d SIM. TO BOLLARD v p DETAIL 7/C6.0 a a d Q p 7/C2.1 p d d p Q d . Q .. 4 d p d. d p pd p 'I II 4 � 4 d 4 p Ll d Q d. p a d p p :p p p. d d. p v ° � p d ° d d 4 d, 4 p p d d p d, p p 4 d d p d p. 4 Q p p p d d d p p d e a p WOODENv vGATE 6' HIGH G ° p. d d. d v p d p d a p. d d p .. .4. d. d Q p p a , d p v d d p 4• p d v. d d p d d p p. p d Q a d a a .. p 4 d a .p. Q .p d d p d p d d p p 4 ° In. 16 d v 4 4 OCONCRETE DUMPSTER PAD 1"=2': 0 2 4 WOODEN BOARD DUMPSTER ENCLOSURE SHALL EXTEND 6'-0" ABOVE EXISTING GROUND SURFACE 8" THICK REINFORCED CONCRETE PAD (POUR CONTINUOUS WITH GENERATOR PAD) Lu ta z 1u Z Z 1 (D W z J F— Z (n LLI J Q z E5 F— LLJW 0 Q Qr a � OQ o 1 U Lu U_ ~ < LL 00 U)m U O W ¢ z /) TH Op �J 000020 Z DANIEL C. HYER 9 LIC. N0. 45596E ZIONAL SN APPROVED DCH SUBMISSION NO. 2 PROJECT 1910500 T H E W 0 R K O F L I N E + G R A D E C2m2 / T. M. 6/ PARCEL /24E2 I I / l SOVRAN BANK N A ZONING: HC USE: COMMERCIAL BANK l CURRENT:(1) CHERRY l 30" OAi( v ORIG. PROP: NONE i �° S21 °W 3653"270.2T ° v E o WAL / BW 5 06 CURB CUT CURRENT:(3) UNIDENTIFIED SHRUB (30 T.M. 6/1DARCEL /24C I------ ORIG. PROP: (2) BUFORD HOLLY ✓K INVESTMENTS LL C / l ° ZONING: PDMC - — CURRENT: NONE USE.- OFFICES; NEWS STA TION s ORIG. PROP: (1) BRADFORD PEAR' R ! � DB 4563 PG J44 CURRENT:(4) CHERRY LAUREL / DB /57/ PG 562-566 ORIG. PROP: (6) BUFORD HOLLY / DS /554 PG I75-177 CURRENT: REMOVE TREED a "1 CURRENT: (1) DOGWOOD I /� / ORIG. PROP: (1) REDBUD 1 ORIG. PROP: (1) DOGWOOD AYCRETEAT tpOOR-52L 95 CURRENT: (1) DOGWOOD ° CURRENT:(4) CHERRY LAUREL ORIG. PROP: (1) BRADFORD PEAR 4 / CURRENT: (6) 00 ORIG. PROP: (1) EASTERN REDBUD CURRENT:(8)CHERRY LAUREL / ORIG. PROP: (6) BUFORD HOLLY 114 ° ° _ _ _ _ _ _ _ CURRENT: (1) WILLOW OAK O BENCHMgR(a' tE /�p ORIG. PROP: NONE :o f7 a +.12LS8 `g +52L88 - T-5 1-5 ° 1 • EX 6 ' SIDEWAL �' 15 1 ELEV. 19.4,5 it1 CURRENT: (1) DOGWOOD y ° / STC I ° ORIG. PROP: (1) DOGWOOD ° / N ° ° ° ° _ ° ° 1 CURRENT:(7) CHERRY (LAUREL / CURRENT: (1) REDBUD I ° ° ° ° ° 1 ORIG. PROP: (6) BUFORD HOLLY ° ORIG. PROP: (1) REDBUD ° ° II / / (/7 \ ° CURRENT: (1) REDBUD S """"���✓ CURRENT: (1) WILLOW OAK ORIG. PROP: (1) REDBUD CURRENT: (1) DOGWOOD ORIG. PROP: (1) WILLOW OAK 7 _ _ +520. /0 ORIG. PROP: (1) DOGWOOD + G4 � _ (I IRRFNT• !41 WII I OW(lAK 520. S 17°2377"W 15.33' L MIJ. t-KUt-: (l) WIL.LUW UAK r i11 r . _a, - O S5002851"E 3.4K7' �y ° / S-2 (T / 0, .T Y °° °° rPWAM N2003570"E 2f4,67 CURRENT: (6) UNIDENTIFIABLE / ORIG. PROP: (7) BUFORD HOLLY CURRENT: (4) HYDRANGEAS \ CURB B X — / ORIG. PROP: (5) BUFORD HOLLY TOP.5/9. I 4 \ /NV. IN.•5 . / l R10 EAS7� OUR (S4 1562), / 50' W ROAD EASEMENT z / B /57/ PG 562 \ ' CURRENT: (1) SOURWOOD - / \ _ ORIG. PROP: (1) SOURWOOD CURRENT: (5) HYDRANGEA \ — — ORIG. PROP: NON 2 LANDSCAPE PLAN 1" = 20': 0 20 40 LANDSAPE LEGEND: STREET TREES PLANTING STRIP (4,409 SF) MANAGED TURF (24,171 SF) INTERIOR PLANTING AREA (8,189 SF) T.M. 6......___ ._ ._. MAKIKA PRO,"ERTR/ES, LLC I ZONING • HC USE: MINIA TORE GOLF I COURSE \ _I_S 12'5148"W 23.00'� B' CyAINLINK SURVEY LlMIT� 4,j _ FENCE-- TW.-5I9. 4 9 I BW.-5/7 09 (I z T M. 6/ PARCEL I24B/ L INUS REAL TY LL C ZONING: PDMC USE.- LAW OFFICES CURRENT: REMOVE TREED ORIG. PROP: (1) REDBUD /8.08 URB BOX TOP.-5/7.53 DUMPS ER INV. IN.•5/0. 96 5 PAD INV. IN.-5I4. 00 S /AA/ in/.5I0.9 CURRENT: (1) REDBUD YT• 0.77 ORIG. PROP: (1) WILLOW OAK II °E CURB BOX OP.S/4.86 NV //V.•509. 62 SE N . IIV.•509.64 NW n//T•5/)O "y; CURRENT: (1) REDBUD ORIG. PROP: (1) WILLOW OAK ORIGINAL VS. EXISTING PLANTING SUMMARY Approved Sire Plan (SDP 199700091) Landscape Materials Original Parking Street Total Quantity Area of Canopy Bonus Key Botanical Name Common Name Currently on t Total Canopy Area Quantity Trees Trees (pertree) Factor Site T-1 Oxydendrum Arboreum Sourwood 6 0 3 3 138SF 1.2S 518 SF T-2 Cercis Canadensis Eastern Redbud 6 3 0 3 396SF 1.2S 1,48S SF T-3 Comus Florida Flowering Dogwood 4 4 2 6 15S SF 1.2S 1,163 SF T-4 Quercus Phellos Willow Oak S 0 3 3 380 SF 1.2S 1,42S SF Total Preserved Canopy Area 4,S90SF Additional Species to be Planted for Conformance with Original Site Plan or Current Requirements Screening Parking Street Proposed Area of Canopy Key Botanical Name Common Name Tree/Shrub Trees Trees Quantity (pertree )i Total Canopy Area T-1 Oxydendrum Arboreum Sourwood 0 0 0 138SF OSF T-2 Cercis Canadensis Eastern Redbud 2 1 3 396SF 1,1885F T-3 Comus Florida Floweri ng Dogwood 2 2 4 15S SF 620SF T-4 Quercus Phellos Willow Oak 0 1 1 380SF 380SF T-S Cupressocyparis Leylandii Leyland Cyprus 8 8 - - S-1 Ilex Cornuta Buford Holly 8 8 S-2 Carex Pendula Carex Grass 20 20 Total Provided Canopy Area 2,188 SF Total Preserved+ Provided Canopy Area 6,778SF Notes 1-The Calculated Canopy Area is what will be used as the basis of estimating preserved caonpy areas, below CANOPY COVER CALCULATIONS Parcel Area: 1.214 AC S2,867 SF Site Use: Commercial Minimum Percent Coverage: 10% Per32.7.9.8(a)1 Canopy Area Required: S,287 SF Canopy Area Provided (see above): 6,778 SF SF Therefore Criteria Satisfied PARKING AREA LANDSCAPING CALCULATIONS w 0 Q U W z J Parki ng and Drive Aisl a Area: O.SO3 21,909 Mini mu m Percent Cove rage: S% AC SF Per32.7.9.6(a) Planting Area Required: 1,095 SF Preserved Parking Area Tree Canopy (From above) Botanical Name Common Name Quantity Area Bonus Canopy Area Cercls Canadensis Eastern Redbud 3 396SF 1.2S 1,48S SF Comus Florida Floweri ng Dogwood 4 1SS SF 1.2S 77S SF Existing Parking Canopy Area 2,260 SF Proposed Parking Area Tree Canopy (From above) Growth Total year Botanical Name Common Name Quantity Height of 10 height height0 years Cercls Canadensis Eastern Redbud 1 396SF 1.2S 49S SF Comus Florida Flowed ng Dogwood 2 1SS SF 1.2S 388SF Proposed Parking Canopy Area 883 SF Total Parking Canopy Area 3, 143 SF Therefore Criteria Satisfied z LIJ STREET TREES C) Q1 0 Frontage on Rio Road Right of Way 153 ft Q LJJ �_ J C) > Req uired Street Trees: 3 Large Street Trees -or- Q W 4 Medium Street Trees 7 z c— O Q C Existing Street Trees 2 Large Street Trees J U U -and- 1 Medi u m Street Trees LLI J !/'1 v, Required (Additional Trees) 1 Large Street Tree Ld Q Provided (Additional Trees) 1 Willow Oak M ;^ 00 v/ W Frontage on Rio East Court Right of V 323 ft DO Q J J O Q Required Street Trees: 6 Large Street Trees z -or- 8 Medi u in Street Trees Existing Street Trees: 1 Large Street Trees 4 Medium Street Trees Required (Additional Trees) 4 Medi u m Street Trees Provided (Additional Trees) 4 Medium Street Trees (2 Redbud, 2 Dogwood) SCREENING ELEMENT TO BE SCREENED CITY Screening Material Refuse Area 2 Leyland Cyprus (Evergreen Dense Shrub) Opaque Wooden Fence Satellite Dishes 6 Leyland Cyprus (Evergreen Dense Shrub) Metal Security Fence Parking Lot Existing 8 Mature Shrubbery, Varios Buford Holly (per original site plan) PATH Op 20 CarrexGrassOn 000020 2 O D DANIEL C. HYER 9 PLANTING SCHEDULE LIC. NO.45596 A Key T-2 Botanical Name Common Name Cercis Canadensis Eastern Redbud Quantity Units 3 EA Min. Nursery Condition Spacing 1-1/2" Cal. �`t�4' SIONAL E� T-3 Comus Florida Floweri ng Dogwood 4 EA 1-1/2" Cal. T-4 Quercus Phellos Willow Oak 1 EA 1-1/2" Cal. APPROVED DCH T-S Cupressocypars Leylandii Leyland Cyprus 8 EA 8'-10'Height S-1 Ikx Cornuta Buford Holly 8 EA 12" #3 Cont. Vo.c. SUBMISSIO^I N11 'Z S-2 Carex Pendula Carex Grass 20 EA 1Gal. #3 Cont. 2.S'o.c. PROJECI 1910500 T H E W 0 R K u L I N E + G R A D E C&O III VARIES SET PLUMB FINISHED GRADE 3" OF MULCH 3" COMPACTED EARTH SAUCER (NOTE: IN PLANTING BEDS, ELIMINATE THE COMPACTED EARTH SAUCER AND COVER ALL BEDS WITH 3" OF MULCH, MINIMUM EXISTING GRADE TILL EXISTING SOIL REMOVE BURLAP FROM TOP Y3 OF ROOT BALL, ROUGHEN ROOT BALL FOR CONTAINER GROWN STOCK 3" OF MULCH FINISHED GRADE PLANTING SOIL MIXTURE ROUGHEN ROOTBALL PRIOR TO PLACEMENT Applicable Standards American Standard for Nursery Stock, ANSI Z60.1-2004, approved May 12, 2004 American Joint Committee on Horticultural Nomenclature; 1942; edition of Standardized Plant Names All plant material shall be nursery grown unless otherwise noted. Plants shall have a habit of growth that is normal for the species and shall be healthy, vigorous and equal or exceed the measurements specified in the plant list, which are the minimum acceptable sizes. Plants shall be measured before pruning with branches in normal position. Any necessary pruning shall be done at the time of planting. Requirements for measurements, branching, grading, quality, ball and burlapping of plants in the plant list generally follow the code of standards currently recommend by the American Standard for Nursery Stock. Plants that meet the requirements specified, but do not have the normal balance of height and spread typical for the respective plant, shall not be accepted. All plants shall be free of weeds and other objectionable vegetation. Plants (General) Plants shall be nursery grown, healthy, vigorous, bushy, well-balanced, of normal habit of growth for the species, and shall be free from disease, insect eggs and larvae. They shall have crown and root ball sizes that meet or exceed the standards set forth in "American Association of Nurserymen, Inc." The specified sizes shall be before pruning, and plants shall be measured with their branches in normal position. Plants shall not be pruned prior to delivery, except upon special approval. Shade trees shall be healthy, vigorous, full -branched, well -shaped, and shall meet the trunk diameter, height, and spread requirements of the plant list, and meet the standards of "The American Association of Nurserymen." Balls shall be firm, neat, slightly tapered and well burlapped. Any tree loose in the ball or with broken ball a time of planting will be rejected. Balls shall be sized in accordance with the AAN standards. Tree and Shrub Planting Plant shade trees in tree -pits greater in diameter than ball and at a height which assures proper drainage and vigorous growth. Plant ornamental trees in tree -pits 12" greater in diameter than ball and at a height for proper drainage and vigorous growth. Fill bottom of pit (to depth of root ball) with a mixture of soil. After settling the tree, the pit shall be backfilled with soil mix, then carefully settled by watering to prevent air pockets. Form a 4" watering ring for each tree. Ground cover beds shall be loosened to a depth of 6" and fertilized with an osmacote fertilizer at the rate of four pounds per 100 square feet. Moist peat moss shall be applied at the rate of two inches (2") thick and worked into the upper six inches (6") of the bed. All plant beds plus an area three feet greater in diameter than the ball around each tree shall be mulched with 3" of clean, hardwood mulch. Should the contractor encounter soil conditions which are inhospitable to normal planting, it is his responsibility to modify the soil so that the plants will thrive. These modifications may include providing drainage for trees or shrub beds and providing any extra soil as may be required for planting. OSHRUB DETAIL O SHRUB SPACING O RUBBER HOSE ON EACH MAJOR STEM, ALL MAJOR STEMS SHOULD BE WIRED TOGETHER ROOT CROWN TO BE PLACED 1"-2" ABOVE SURROUNDING GRADE HARDWOOD MULCH, 3" MIN. SOIL SAUCER: USE PREPARED TOPSOIL, 6" MIN. WOOD STAKES (3) IN FIRM SOIL REMOVE TOP 3 OF BURLAP, NON -BIODEGRADABLE MATERIAL SHALL BE TOTALLY REMOVED PREPARED ADMIXTURE BACKFILL PREPARED SUBGRADE PEDESTAL ROOT CROWN TO BE PLACED 1"-2" ABOVE SURROUNDING GRADE HARDWOOD MULCH, 3" MIN. SOIL SAUCER: USE PREPARED TOPSOIL, 6" MIN. PLANTING NOTES REMOVE TOP 3 OF BURLAP, NON -BIODEGRADABLE MATERIAL SHALL BE TOTALLY REMOVED PREPARED ADMIXTURE BACKFILL PREPARED SUBGRADE PEDESTAL TO PREVENT SETTLING CROWN OF SHRUB TO BE PLACED 1"-2" ABOVE SURROUNDING GRADE HARDWOOD MULCH, 3" MIN. CREATE SAUCER WITH TOPSOIL, 6" MIN. PRUNE DAMAGED OR DESSICATED ROOTS GENTLY COMPACTED TOPSOIL MIXTURE SCARIFY PIT BOTTOM, 6" MIN. FIR 04 •• w 0 Q U W Z F— w¢ � z Z 0 w Q � Z z J 0U LU LLJ it F-Q FnLU �m J OQ Z I► ta Z UJ UJ Z Z UJ UJ 0 TH Op� 000020 Z DANIFL C. HYER 9 Lic. N0. 45596, '10NAL BX APPROVED DCH SUBMISSION NO. 2 PROJECT 1910500 T H E W 0 R K O F L I N E + G R A D E OTREE PLANTING O MULTI -STEM TREE PLANTING O SHRUB PLANTING C3ml 61 PARCEL /24E2 7VRAN BANK N A ZONING: HC COMMERCIAL BANK L=971.64, R=313.62 C4 S 17°23'1 T. M. 6/ PARCEL /24EI I MAKIKA PROoERTR/ES, LLC I ZONING • HC USE: MINIA TURF GOLF I COURSE \ _IS 12'5148"W 23.00'� g' CHAINLINK SURVEY LIMIT FENCE -- CURB BOX \ n OP.514.86 /NV //V.•509. 62 SE /N . /1V509.64 NW 011T 0 MATERIALS PLAN 1" = 20': 0 20 40 (I Z T. M. 6I PARCEL I24B/ L INUS REAL TY LL C ZONING: PDMC USE.- LAW OFFICES URB BOX TOP.-5/7.53 INV. /N.•5/0.96 INV. /N.-5/4.00 INV. /N.•5/0.9� /NV. OUTS 9 ; MATERIALS LEGEND: ASPHALT CONCRETE LANDSCAPING OR GENERAL IMPERVIOUS STRUCTURES w 0 Q U W z z LEI 2¢ Z_ 0 � � Q LLJ O Q H zz 0 � J O w ~ < 00 cl) w m OJ Q z ta Z uj uj z Z uj TH Op--vt 000020 2� DANIEL C. HYER 9 Lic. N0. 45596, IOKAL APPROVED DCH SUBMISSION1 Nl' 2 PROJECI 1910500 T HE W OR K u L IN E + G R AD E C400 s NOTES: 1.) SOURCE OF MERIDIAN: VIRGINIA STATE PLANE GRID NORTH, NAD 83 SOUTH ZONE BASED UPON GPS OBSERVATIONS PERFORMED BY DRAPER ADEN ASSOCIATES ON OCTOBER 10, 2019. 2.) VERTICAL DATUM:NORTH AMERICAN VERTICAL DATUM OF 1988 BASED UPON GPS OBSERVATIONS PERFORMED BY DRAPER ADEN ASSOCIATES ON OCTOBER 10, 2019. 3.) THIS SURVEY WAS PREPARED WITHOUT THE BENEFIT OF A TITLE COMMITMENT OR TITLE REPORT AND ALL EASEMENTS AND ENCUMBRANCES THAT MIGHT BE DISCLOSED IN A TITLE SEARCH MAY NOT BE SHOWN. 4.) UTILITIES SHOWN ARE BASED UPON: SUE QUALITY LEVEL D, ASCE 38-02 - COMPILED RECORDS ONLY SUE QUALITY LEVEL C, ASCE 38-02 - VISIBLE EVIDENCE IN CONJUNCTION WITH COMPILED RECORDS. X SUE QUALITY LEVEL B, ASCE 38-02 - FIELD DESIGNATION OF UNDERGROUND UTILITIES PERFORMED BY DRAPER ADEN ASSOCIATES AND VISIBLE EVIDENCE IN CONJUNCTION WITH COMPILED RECORDS. SUE QUALITY LEVEL A, ASCE 38-02 - TEST PITS AT LOCATIONS SHOWN HEREON PERFORMED BY (DAA; OTHER) IN CONJUNCTION WITH FIELD DESIGNATION OF UNDERGROUND UTILITIES PERFORMED BY (DAA; MISS UTILITY, TICKET # OTHER), VISIBLE EVIDENCE AND COMPILED RECORDS. NO SUE WAS PERFORMED OR REQUESTED FOR THIS SURVEY. UTILITIES SHOWN HEREON ARE BASED ON FIELD OBSERVATION ONLY. 5.) THIS TOPOGRAPHIC SURVEY WAS COMPLETED UNDER THE DIRECT AND RESPONSIBLE CHARGE OF DAVID JORDAN FROM AN ACTUAL GROUND SURVEY MADE UNDER MY SUPERVISION; THAT THE IMAGERY AND/OR ORIGINAL DATA WAS OBTAINED ON OCTOBER 10, 2019; AND THAT THIS PLAT AND/OR MAP MEETS MINIMUM ACCURACY STANDARDS UNLESS OTHERWISE NOTED. 6.) CONTOUR INTERVAL: 1'. 7.) THIS SURVEY WAS PREPARED FOR LINE + GRADE. DRAPER ADEN ASSOCIATES ASSUMES NO LIABILITY FOR REUSE OR MODIFICATION OF THIS DOCUMENT. 8.) PROPERTY LINES SHOWN HEREON ARE COMPILED FROM RECORD INFORMATION. 9.) DRAPER ADEN ASSOCIATES PROVIDES BENCHMARKS FOR THE CONSTRUCTION OF THE IMPROVEMENTS SHOWN ON THESE PLANS. ALL OTHER EXISTING ELEVATIONS ARE FOR REFERENCE TO EXISTING CONDITIONS ONLY. DO NOT USE SPOT ELEVATIONS, FINISH FLOOR ELEVATIONS, ELEVATIONS ON MANHOLES, ELEVATIONS ON SURVEY NAILS, SURVEY HUBS, CONTROL POINTS (HORIZONTAL POINTS PROVIDED) OR ANY OTHER POINTS FOR CONSTRUCTION OTHER THAN THE PROVIDED BENCHMARKS. FAILURE TO UTILIZE AND VERIFY THE PROVIDED BENCHMARKS COULD RESULT IN DAMAGES AND ADDITIONAL COST THAT ARE THE CONTRACTOR'S RESPONSIBILITY. 11.) THE RECORD INFORMATION CONCERNING THE SANITARY SEWER AND DRAIN EASEMENTS SHOWN HEREON IS BASED ON AN AS -BUILT SURVEY, PROJECT NUMBER 368, THAT WAS PREPARED BY B. AUBREY HUFFMAN AND ASSOCIATES, LTD. ENTITLED "AMENDED FINAL SITE DEVELOPMENT PLAN SHOWING RIO EAST OFFICE ONE - RIO EAST COMMERCIAL AREA - TAX MAP 61 PARCEL 124 C - SEWER & WATER AS -BUILT DRAWINGS," DATED SEPTEMBER 28, 1999; A COPY OF WHICH WAS PROVIDED BY THE ALBEMARLE COUNTY SERVICE AUTHORITY IN THE PREPARATION OF THIS MAP. NO INSTRUMENTS OF RECORD FOR THE GRANTING OF SANITARY AND DRAIN EASEMENTS WAS FOUND AT THE TIME OF THE SURVEY. BENCHMARK "B" CHISELED SQUARE ELEV:519.43 A LEGEND PROPERTY LINE O RO - - - -1000- - - CONTOUR ❑ M g GAS LINE O TE ohP OVERHEAD POWER QT TE ID ���V _� `•'' u9t fo u t fo 36" OAK fo 8" TREE fo g fO CHit FEN-C J. u t 8 \ 1,I __111 •�• v \ 1 •� DRAPER ADEN ASSOCIATES REVIEW CONCRETE - - - '-D - - - D - - - - - - `~1`\ 1 -• WA L _ - - `\ �\ 524.36+ 1 f , / / • THESE PLANS HAVE BEEN SUBJECTED TO TECHNICAL AND QUALITY REVIEWS BY: 522.01 521.66 �� ,'�� ■ TW:523.06 `\ \ ` 1 1 / / / ■ `� BW:521.90 \ \ \\\ \ I I r , / , .• NAME: JUSTIN SIDEBOTTOM /Lf w_ 10 15 2019 ■ H r \\` \\ �`� 1, f 1 j I / /T 519.49 ■ / / ■ 521.47 \ \ 1 I I 1 8 .517.09 SURVEY PARTY CHIEF =SIGNATURE DATE ■ cuR6 cur - \ ` I 1 1 I I 1 ■ �' `� j NAME: TYLER LAYMAN cS 10/14/2019 ■ SUBSURFACE UTILITY ENGINEER SIGNATURE DATE 1 1 ■ I NAME: DAVID JORDAN 10/14/2019 ■ j PROJECT MANAGER SIGNATURE DATE ■ , / 8' WOOD FENCE ■ +521.69 j NAME: CHERYL STOCKTON 10/15/2019 ■ QUALITY REVIEWER SIGNATURE DATE ■ �/ 520.09 ■ 521.86 r f j d . ///�//� /// 1 / ■ I � a ■ � p 10" REDBUD ■ ■ o CONCRETE AT N ■ BAY DOOR:521.95 I / ■ < I 520.24+ / ■ Ca/ /I / PID 06100-00-00-124CO : O ; JK INVESTMENTS, L.L.C. o s io go INST 2019000126777 ■ O j / BENCH DB 4563 PG 344 ■ f / CHISEL 1 inch= 10 ft. DB 1571 PG 562-566 ■ o r / ELEV:5 DB 1554 PG 175-177 ■ o 9e / ■ a I / 15' VEPCO EASEME ■ Ln / DB 1594 PG 66: ■ O71 / / P o e 521.98 a 4 0 521.64 Q d. +521.88 4 a +521.88 ... d . 41 +521.894 v .4 17 a / chNN Ln0 N Q 11 \\1 \ 00 4l ;1 11 11 \\ i i� l i�■ � i 0 , I 1 1 1 1 ' li ^� �12" 0 K11 `. 1 1 11 1 ; 1■ // W 1\ o I i II ; 111 ■ ° 1 • �\ i � 1 1 r � 1 I ; 1 I � I / Iw ■ REDBUD \\ I I 0 11 / O■ \ 1 f Z■ z■ 1 o I / / On i I I i a■ QUARE i I I 1 d 0517.06 I I I � ■ , I ^' 1 I 1 I ■ i I' 1 � / � i ■ 1 40 j ■ C / v f 1 ■ � o 1 I f I 1 \ I ■ 1 f 1 1 1 1 1 I 1 v 1 1 1, 0 I 1 REDBUD/ '10" REDBUD / ' e ° / 20' ACSA SANITARY SEWER EASEMENT // �,' / ° o ■ CENTERED ON THE AS -BUILT N ° r -D a CENTERLINE OF THE STRUCTURES ss ass SANITARY SEWER AND ® TELEPHONE BOX UTILITY POLE n' STCo / cge 1 ; / I Do N ■ (SEE NOTE 11) MANHOLE �// � -6 FIRE HYDRANT ❑E ELECTRIC TRANSFORMER / // � m STORM LINE AND MANHOLE < ��� i I o, ■ -❑- _ ® WATER VALVE > GROUND LIGHT n' STORM LINE AND INLET � ■+s2o.10 � s I I ■ COtV ■ +520.13 _ �20• � _ � - - APPROXIMATE LOCATION //' +518.78 O .o /'/ 1 I Q 6 WATER METER -O- LIGHT POLE ■ _-- - -- - 2CENTERED0' DRAIN EONETHET 15D8E59� PGEASEMENT /'' O ClGciLL�' ° ° Im I `Tj O Z - - - - - - - UNDERGROUND CABLE TV y ■ AS -BUILT CENTERLINE ,/ CURB BOX 0, �\ I ■ p uge �o WELL O FIBER OPTIC PEDESTAL OF THE STRUCTURES ,/ TOP:517.53 ,� F sG2 ° I I U m UNDERGROUND ELECTRIC (SEE NOTE 11) INV. IN:510.96 SSW INV. IN:514.00 SW > ugt * BENCHMARK ❑F FIBER OPTIC HANDHOLE ■ , UNDERGROUND TELEPHONE INV. IN:510.90 NW / J '� �liG9191i� 10" REDBUD \ i _ ` . U) L.I L- INV. OUT:510.77 /w w �iP 'S O 1 to O BOLLARD 0 GAS VENT ■ .' ¢VJ _j UNDERGROUND FIBER OPTIC = ■ _ unk SIGN (1-POST) O GAS VALVE - �'� / o� Mae ° m /1 1 ■ UNKNOWN UTILITY / // ,,S�e ��� - J / i ■ uj W w �� SIGN (2-POST) GAS METER e" DOGWOOD \� I ■, m WATERLINE 8" SHAGBARK �/ �/' TD q u- /' 1 a J HICKORY u e uge uge s /i /'! u e o d / I L L a ASPHALT +1561.3 SPOT ELEVATION O SEWER CLEAN OUT \ / uge ge / / u e u e ^ge_ . R T (/, `L g o ss 1 ss ss PTT77T71 \/\ / g - 02j/eLL lr�RFgS�q! I 1 E o SANITARY 1 ■ 8" PVC / O ��/�Jy DECIDUOUS TREE ® WOOD POST / /\�/ nr! q F F T BUILDING \ �9 V qy ' ! TOP:516.73 ■ ■ ■ ` O } -x X-AV/EVERGREEN TREE ® METAL POST // 519.13 ---� _ qY Pq 9 - ■ �!F / '� u e I INV. OUT: 0 A z FENCE (AS NOTED) /L 518.24 ■ 1 SHRUB GRAVEL ■ / / ` ---- T . 6" SOURWOOD ' STREAM STCO �/ `�� leer / / / ---- --- - -- �- - --- - - - - - M O CONCRETE O STORM CLEANOUT------- \� - --------------u e/`�/�� s ��\�\��\`�\`�`\��� ----- �- _ //' `�--p-----------------= F- W U <.---------- uge \\/\/\/\ /\ \ j/////// / \ ,/' 28' VEPCO EASEMENT\ o 12 OAK / REVISIONS TREELINE F TRANSFORMER HVAC // %jG //�//�// / // �/ �/ �/ / / �\ \�t ZL03/26/2020 GUY WIRE _� / ��\�i�'`�/��J�/� /�/ // //j\ Q1rYQ/DB 1594 PG 662 _ �//.01 ® OUTLET PANEL ® ELECTRIC METER �� _ 15" / \/\ \ \\� - -__-_ -< / ��-------- RCPJ ____________ ESMTS ADDED/NEW OWNERSHIP -fir v MAILBOX _ _ t / - ■ / .. .' 4 / 4 _ _ - - -r - - - - - - ■ / n ---- R a. _ - ■ J U I'"� ■ / I l rt ■ 15" RCP CURB BOX ■ `�\\ ` S TOP:519.51 1 ■ 10' STREET EASEMENT ! 1 `Sj I I a 7R ■ INV. IN:513.94 1 INV. OUT.,513.78 1 ■ DB 1571 PG 554 `Sly` ■ RIO EAST COURT ` ■ '� \\�`. 50' WIDE ROAD EASEMENT ■ \�� `\ DB 1571 PG 562 \II I " 1 ■ DESIGNED BY: \ I■ I ■ 1 ``\� \\\ - - - - - / ■ DRAWN BY: DAJ / n II ■ - - - - - �� / ' CHECKED BY: ■- - - -T / I I .-` CAS / ■ // ,,. /// SCALE', / lti 1'. = 10' / ■ / ' / , ' // I I CURB BOX ° �,i : DATE. 10/10/2019 INV. IN: 509.62 SE f0 /' ■ PROJECT NUMBER: / ■ / / INV. IN:509.64 NW ■ 19060499-010503 / ■ / /' / // I I INV. OUT:509.53 ' / / ■ / / / / ....................................■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■ ■■■■■ ■■■■■■■■■■ zzz■■■ XO.O SURVEY LIMITS Q 18" RCP 0 David Jordan Lie. No. 2976 3/26/2020 9�d . S U R`) 777 EC STCO D FOUND ❑f ELECTRIC BOX