HomeMy WebLinkAboutARB202100106 Staff Report 2021-09-29ARCHITECTURAL REVIEW BOARD STAFF REPORT
Project #/Name
ARB-2021-106: Southside Tier 2 PWSF
Review Type
Advisory Review fora personal wireless facility; Certificate of Appropriateness for ground equipment
Parcel Identification
087000000022E0
Location
2415 Southside Drive, North Garden See Fig. 1.
Zoned
Rural Areas RA / Entrance Corridor EC
Owner/Applicant
Roy Thomas or Lisa Fitzgerald / Parallel Infrastructure Hadisha Gordon
Magisterial District
Samuel Miller
Proposal
To construct a personal wireless services facility consisting of an 87'-tall monopole and associated equipment, including a
request for a Special Exception See Attach. A.
Context
The surrounding area is rural/rural residential. Nearby, at the southwest comer of the intersection of Rt. 29 and Red Hill Rd.
(3017 Monacan Trail Rd.) is the Trading Post convenience store with a fuel pump canopy and two PWSF monopoles. (See
Fig. 2.
ARB Meeting Date
October 4, 2021
Staff Contact
Margaret Maliszewski
HISTORY: The ARB has reviewed no previous proposals for this property. A letter outlining opposition to this proposal was received on Sep. 27. (See
Attach. B.)
PROJECT DETAILS The proposal includes the following:
• Installation of an 87'-tall monopole within a fenced 50' x 50' compound in a 100' x 100' lease area, with monopole located approximately 178' from
the Rt. 29 right-of-way.
• Installation of ground equipment including a utility H-frame with meter and cabinet.
• Installation of a 6'-tall chain link fence around the compound, with barbed wire on top.
• Creation of a 20'-wide access easement with 12' gravel access road to the lease area.
• Installation of 6 antennas (72" high x 19" wide x 8" deep), 2 raycap squids, and 3 Remote Radio Heads on pipe mounts.
o A Special Exception is requested to allow the antennas to be mounted 63" from the face of the pole. The plans do not show where the
measurement is taken.
• The reference tree is identified as 77' tall. Z-6 shows the tree immediately adjacent to the monopole and to be removed (which is not allowed for a
Tier II facility); Z-3 illustrates a "tallest tree within 25 feet" a few feet beyond the fenced area, which places the trunk beyond 25' from the facility.
• Monopole, antennas, RRHs and associated mounting equipment are proposed to be painted Woodsy Brown SW 2924. A paint sample was not
provided.
• A future lease area of 435 sf is also shown within the compound.
ANALYSIS REGARDING THE GROUND EQUIPMENT
A Certificate of Appropriateness from the ARB is required for the base equipment portion of this proposed telecommunications facility. The ARB may
impose conditions on the Certificate of Appropriateness, based on the EC Guidelines, and consistent with Section 5.1.40 of the Zoning Ordinance.
Ref
Guideline
Issues
Recommendations
17
Accessory
The plans show a monopole with a utility H-frame
Because there is insufficient information provided to confirm
structures and
with meter and cabinet within a compound
that visibility of the ground equipment and chain link fence will
equipment: The
surrounded by a chain link fence topped with barbed
be eliminated, staff does not recommend approval of the
following should be
wire. This is less ground equipment than is typically
Certificate of Appropriateness for the ground equipment and
screened to eliminate
proposed. The ARB has consistently not approved
base station at this time. Staff recommends that the following
visibility from the
chain link fence visible from the EC street. At its
information be submitted for further consideration:
Entrance Corridor
closest point, the fence would be located
1. Provide a tree plan that locates individual trees and trees to
street:
approximately 150' from the Rt. 29 right-of-way.
be removed, keyed to a list that provides species, caliper
e) Mechanical
Sheet Z-1 shows trees to remain that would screen
and height. Ensure that there are sufficient trees to remain
equipment
the view of the fence from the street. However, the
on site to eliminate visibility of the ground equipment and
g) Chain link fence
trees appear to be symbols generally signifying a
chain link fence from Rt. 29.
wooded area rather than actual existing trees in
2. Confirm that there is no ground equipment proposed beyond
specific locations, with many of the trees located
the utility H-frame with meter and cabinet as currently
off -site in the right-of-way, so the extent of actual
illustrated on the plan. If additional equipment is proposed,
screening that will be provided is unclear. More
show it on the plan.
specific information on existing trees and trees to
remain is needed to confirm that equipment and
fencing won't be visible from the EC street.
ANALYSIS REGARDING VISIBILITY OF THE FACILITY AND THE SPECIAL EXCEPTION REQUEST
The ARB may act man advisory ca aci to the Agent as to whether the facility is being sited to minimize its visibili
Ref
Guideline/Ordinance
Issues
Recommendations
33
Development
A balloon test was conducted on September 16, 2021. A balloon
Given the degree of visibility
pattern: The
measuring 12.5' x 9' was used to represent the proposed 63" standoff for
displayed at the balloon test and
relationship of
the antennas. Due to the density of the wooded area and the size of the
the intrusive and incompatible
buildings and other
balloon, the balloon was not flown from the proposed monopole
appearance of the proposed
structures to the
location. Instead, it was flown in the clearing between the wooded area
standoff, staff recommends that
Entrance Corridor
of the site and the wooded street frontage, approximately 80' north of
the proposed location of the
street and to other
the Rt. 29 right-of-way and 150' southeast of the proposed monopole
facility does not sufficiently
development within
location.
minimize the visibility of the
monopole from the Rt. 29 EC
the corridor should be
The test revealed that the balloon was visible from Rt. 29 in various
and staff does not recommend
as follows:
locations between Rt. 708 (Red Hill Rd.) and just west of Rt. 710
approval of the Special
f. The placement of
(Taylors Gap Rd.), a distance of approximately one mile (Fig. 3). It was
Exception. The following
structures on the site
most visible from the vicinity of 2936 Monacan Trail Rd. (Fig. 4) to just
changes/ submittals are
should respect existing
west of the Rt. 710 intersection, a distance of approximately 1/3 mile.
recommended for additional
views and vistas on
When it was visible, the balloon was skylit (Fig. 5). It is anticipated that
consideration:
5.1.40.b(2)(c)
and around the site.
a balloon flown from the actual proposed monopole location would have
1. Revise the proposal to flush
similar visibility and would also be skylit. The test showed that the 63"
mount antennas.
Projection...... in no
standoff, as represented by the balloon, does not minimize visibility of
2. Provide photo -simulations of
case shall the closest
the facility. It results in a structure that is an intrusion in the landscape
the proposed facility.
point of the back of
and incompatible with the surroundings. The standoff does not minimize
3. Provide to -scale drawings
the antenna be more
the visibility of the facility; rather, it highlights it. There is potential,
showing the pole and
than 12 inches from
however, that the proposed site might be appropriate with a facility using
antennas and the distances
the facility ... and in
flush -mounted antennas.
from pole to antennas and
no case shall the
mounting equipment.
farthest point of the
There is inconsistent/incomplete information in the plan set, so it is
4. Show the reference tree
back of the antenna be
difficult to predict what additional impact proposed tree removal could
accurately on all relevant
more than 18 inches
have on visibility of the proposed facility. Z-6 notes that all vegetation
plans. Include the distance
from the facility...
within the 50' compound is to be removed, including the reference tree,
from the pole to the tree
and Z-1 shows no trees within the 100' lease area. To qualify as a Tier 11
trunk. Note that to qualify as
facility, the site must retain a reference tree with a trunk no more than
a Tier 11 facility, the site
25' from the monopole. A landscape plan/tree inventory showing that
must retain a reference tree
sufficient on -site tree cover, including a reference tree, will remain to
with a trunk no more than
mitigate visibility, would be helpful. Photo -simulations could help
25' from the monopole.
clarify visibility of the facility in its actual proposed location.
5. Submit a paint sample for
SW2924.
The proposal includes a "Woodsy Brown" paint for the pole and related
equipment. A physical sample of the paint color could confirm that it is
coordinated with the wooded surroundings.
Figure 1: Project location. The yellow star marks the general location of the proposed facility.
The red triangle marks the approximate location from which the balloon was flown.
Fig. 2: Existing PWSFs at the Trading Post, 3017 Monacan Trail Rd. View from Red Hill Rd. near the intersection with Rt. 29, facing southwest.
Figure 3: The subject parcel is highlighted in yellow. The purple line shows the segment of the Rt. 29 Entrance Corridor where views of the balloon were
available. The red lines mark the area of clear, sustained views. Outside the red lines, views were intermittent. When visible, the balloon was skylit.
Figure 4: View of the balloon from the northbound lanes of Rt. 29 at 2991 Monacan Trail Rd., facing northwest.
Figure 5: View of the balloon from the northbound lanes of Rt. 29 at 2991 Monacan Trail Rd., facing northeast.
SUMMARY OF RECOMMENDATIONS
Points of Discussion
1. Anticipated visibility of the monopole
2. Anticipated visibility of the ground equipment and chain link fence
3. Visual impacts of the proposed 63" antenna standoff
Recommendations
Regarding the Certificate of Appropriateness for the ground equipment and base station:
Because there is insufficient information provided to confirm that visibility of the ground equipment and chain link fence will be eliminated, staff does
not recommend approval of the Certificate of Appropriateness for the ground equipment and base station at this time. Staff recommends that the
following information be submitted for further consideration:
1. Provide a tree plan that locates individual trees and trees to be removed, keyed to a list that provides species, caliper and height. Ensure that there
are sufficient trees to remain on site to eliminate visibility of the ground equipment and chain link fence from Rt. 29.
2. Confirm that there is no ground equipment proposed beyond the utility H-frame with meter and cabinet as currently illustrated on the plan. If
additional equipment is proposed, show it on the plan.
Regarding visibility of the facility
Staff recommends that the ARB forward the following recommendation to the Agent:
• The ARB finds that the proposed location will not sufficiently minimize the visibility of the monopole from the Rt. 29 Entrance Corridor. The ARB
recommends the following changes/submittals for additional consideration:
1. Revise the proposal to flush mount antennas.
2. Provide photo -simulations of the proposed facility.
3. Provide to -scale drawings showing the pole and antennas and the distances from pole to antennas and mounting equipment.
4. Show the reference tree accurately on all relevant plans. Include the distance from the pole to the tree trunk. Note that to qualify as a Tier II
facility, the site must retain a reference tree with a trunk no more than 25' from the monopole.
5. Submit a paint sample for SW2924.
Regardingthe he Special Exception:
Staff recommends that the ARB forward the following recommendation to the Agent:
• The ARB does not recommend approval of the Special Exception due to the intrusive and incompatible appearance of the proposed standoff. The
ARB recommends the following changes/submittals for additional consideration:
1. Revise the proposal to flush mount antennas.
2. Provide photo -simulations of the proposed facility.
3. Provide to -scale drawings showing the pole and antennas and the distances from pole to antennas and mounting equipment.
4. Show the reference tree accurately on all relevant plans. Include the distance from the pole to the tree trunk. Note that to qualify as a Tier II
facility, the site must retain a reference tree with a trunk no more than 25' from the monopole.
5. Submit a paint sample for SW2924.
ATTACHMENTS
Attach. 1— ARB2021-106 Southside Tier 2 plans
Attach. 2 — ARB2021-106 Southside Tier 2 correspondence
TABLE 1 This report is based on the September 16, 2021 balloon test and the following submittal items:
Sheet #
Drawing Name
Drawing/Revision
Date
T-1
Title Sheet
8/9/21
1 of 3(survey
information
2 of 3
Site Information
3 of 3
Leal Description Sheet
Z-1
Plan View
Z-2
Proposed Site Plan
Z-3
Elevation
Z-4
antenna information
Z-5
Equipment Specifications
Z-6
Tree Height Stud
Tree Height Stud hoto)
Tree Height Stud(photo)
Special Exce tion Request
8/20/21
10