Loading...
HomeMy WebLinkAboutWPO201700048 Calculations 2021-07-14OLD TRAIL CREEKSIDE III, PHASE II STORMWATER MANAGEMENT CALCULATIONS PACKET (WPO 201700048, Amendment #1 to WPO 201200008) Date of Calculations JUNE 81 2020 SCOTT/R. MUINSZ IAc. No. 035791 � 7/14/21 ZONAL APPROVED by the Albemarle County Community Development Department Date 09/14/2021 PREPARED BY: File WP0201700048 (Amendment #1 to WP02012-00008) COLLINS CNGINEERING 200 GARRETT STREET, SUITE K CHARLOTTESVILLE, VA 22902 434.293.3719 PH 434.293.2813 FX www.collins-engineering.com Stormwater Management Amendment #1 Narrative: Overall: The approved WPO 201200008 plans specify for the conversion of a sediment basin to a bioretention basin. However with this amendment, and the stabilized site and basin, the proposed conversion is no longer necessary and limited modifications to the facility are needed. These modifications include proper installation and maintenance of the riprap lined outfall channel, converting the riser to have an inlet top and stabilizing the sediment basin with positive drainage to the new inlet. This plan also shows continued compliance with stormwater requirements. Please see this sheet and the attached calculations for additional information. Water Quality: The approved plan achieved water quality compliance through a contribution to the Lickinghole basin fund and a biofilter treating the first 1/2" of rainfall. This amendment however proposes to eliminate the conversion to a biofilter and achieves water quality compliance through the previously paid contribution to the Lickinghole basin fund and through a new nutrient credit purchase. Water Quantity: The approved plans utilized an adequate riprap lined channel that was not erosive during the 2- year design storm and was contained within its banks during the 10-year design storm. This channel, labeled 'MS-19 X-Section' on the approved plans, extends to the Lickinghole Creek bank where the analysis ends since the site's contributing drainage area is 1% of the creek's overall watershed. This methodology is per the approved plans and this amendment does not modify the adequate channel or the concept. This amendment does however confirm the approved 'MS-19 X-Section' continues to not be erosive during the 2-year design storm and continues to not overtop the riprap channel's banks during the 10-year design storm. This design also removes the existing temporary sediment basin by modifying its riser to have an inlet top and to ensure the facility remains dry, stabilized and sloped towards the newly installed inlet top. Please note, this project has an approved stormwater quantity waiver dated 9/26/05. Though this waiver was not utilized with the approved plan, this waiver will no longer be valid with the approval of this amendment since the waiver relied partially on the installation of a biofilter. This is in accordance with prior County Engineering direction dated 3/30/17. In keeping with the approved plan, water quantity compliance for this amendment will be addressed through the use of the riprap lined channel (i.e. the MS-19 X-Section). Channel protection is met through 9VAC25-870-66, subsections B.1.a and B.4.a and flood protection is met through 9VAC25-870-66, subsections C.2.a and C.3.a. The flows used in these analyses were taken from the approved post -development inflow hydrographs and assumed zero attenuation occurs onsite. Please see this report and the accompanying VSMP Amendment #1 for details. DEQ Virginia Runoff Reduction Method Water Quality Calculations (COMPLIANCE IS MET THROUGH THE BEST MANAGEMENT PRACTICES OF A CONTRIBUTION TO THE LICKINGHOLE BASIN FUND AND THE PURCHASING OF NUTRIENT CREDITS.) Impervious Area Breakdown for the Approved Old Trail Creekside III, Phase II Subdivision (Values taken from Approved Sheet 1 of 1) Roadway 50,375 sf Sidewalk 7, 575 sf Lots 57,200 sf 115,150 sf Water Quality Notes: 1. A contribution to the Lickinghole Basin Fund was made with the originally approved WPO plan. 2. The approved plans, as shown on sheet 1 of 1, require a phosphorous removal rate of 4.98 Ibs/yr. 3. The following DEQ VRRM water quality calculations require a phosphorous removal rate of 5.14 Ibs/yr, when entering the approved impervious areas and the development's total acreage. 4. A required phosphorous removal rate of 5.14 Ibs/yr is the more conservative of the two rates listed above. And per the County's guidance on 9/19/14 stating "the Lickinghole Basin may be used to account for 30% of the pollutant load leaving the sitP', this amendment requires a nutrient credit purchase of 3.60lbs/yr (0.70 x 5.14). CCQWBIMn FumgFEduCM MCM New OeuebpmeMCmplMrce SpeadsM1eel-Ven n3A ❑ W219MP Standaxds and 5pedllodons O2013 Ma1tPMP M mbWs a 8PeM4atlms Pmjl Name: Old Tmil Crc Wde III, Phase 11 V MP Amendment 91 Date: 6/8/2020 amvcesryn spxipanimrstiat M1302h5tdi L5p: A Site Information Post -Development Project (Treatment Volume and loads) Umd Q,mv laves) A i, B5 11 CSmis °soih m n.xV4en W.ANoce -� . °o6x m.mparwl+wxl-�rh.e wee/manageEM N.J9 are Lawl•�1 zM 2M C..... man lrKhexl 03 1.wn.1 Erem Mmexl 1.°6 Iwux lml EMLlma/LI 0.J6 a¢en ONI EMLIme/Il 1.66 ,,TPwe Ow-mm) a.a1 rrenMn N.ml °96 wren/0Rn 6pa rarer Care:1 6.o° WeidRea Brllnrert) On° X fore# %4 Manaparwt�.erlare9 to.n WeyMea Br(mM OM %Man Tmi BO% Impe.rioreLwer laved 26e Pr(imRniousl 0.95 %IM, EO% sre Area (ere:) 13A3 eunPN Ceelfiuents )eel T emvM.me laoenl o3ea4 TresMen[Vdume Curtis Amt) 16938 1P IUM lIh/yrC ]pM dm�atamra®Ik lun daYianeelle u W U X X X X X H O S E S S 00 O 00 O o 0 o a W 1' Q W D S 0 S 0 S 0 O 0 S 0 Y 0 W O pp O p SG SC SC D�SSBSSx O O C G G D 0 O U aS88SSx Qos88 8 a G O V m o o a 0 m o 0 0 p G C G G O o c c c c m 7 W f�0 3 aS888sx O dOS86 S�S� _ o000000 0 00 a N 7 N ......... ... � .._ .., Faw L% 1 N 0 U 0 0 Q Q £ W Q ow O S" L N a O W C? 0 0 WA `WU C K C7 N x Q O 2 W S O p j c W y zd FSz W Q d F rc Q x C W O W Q V' N W 0U Q C z 1' z W z z C z Y d z C a 'g�ij m � W F a F 0 r-xr E OF 02 W F W W W W F W W W W 6 l9 Q F C V >> O O O 00 Y d J OJ J O !ip0 W f N C L Y.O W Q 6 z OJ p p 1 p C z W F W a F F F W C z F O ? 2 to O N C OC F z Y F 6 O z Q Z z U' z � Q W O � W Q C_ Verification of the Approved Outfall Channel's Adequacy to Lickinghole Creek * Summary of the Approved Post -Development Contributing Watershed for the Old Trail Creekside III. Phase II Subdivision Drainage Area 9.16 ac. Weighted CN Value 70.6 Time of Concentration 0.31 hrs. 2-yr. 24hr. SCS Design Flow 7.36 cfs 10-yr. 24hr. SCS Design Flow 16.03 cfs *These values were taken from the approved WPO 201200008 biofilter routing calculations shown on sheet 1 of 1. These values represent the inflow hydrographs for the contributing watershed to the biofilter that will not be installed. Adequate Channel Confirmation- 2 Year Complex Channnel: 2-yr design storm Verification of Channel Adequacy for the Approved Flows through the Approved Channel Input: Slope Flow (given) line x y n 0 0.000 1.000 0.095 (first n value not used) 1 3.000 0.000 0.095 2 6.000 0.000 0.095 3 9.000 1.000 0.095 Output: Depth 0.552 (y) ( 0.552) Channel bed segment output: line A P 0.46 1.75 1.66 3.00 0.46 1.75 Q V 1 0.92 2.02 2 5.51 3.33 3 0.92 2.02 Page 1 Adequate Channel Confirmation- 10 Year Complex Channnel: 10-yr design storm Verification of Channel Adequacy for the Approved Flows through the Approved Channel Input: Slope Flow (given) line x y n 0 0.000 1.000 0.095 (first n value not used) 1 3.000 0.000 0.095 2 6.000 0.000 0.095 3 9.000 1.000 0.095 Output: Depth 0.821 (y) ( 0.821) Channel bed segment output: line A P 1.01 2.60 2.46 3.00 1.01 2.60 Q V 1 2.67 2.64 2 10.69 4.34 3 2.67 2.64 Page 1