Loading...
HomeMy WebLinkAboutSDP202100049 Plan - Revision 2021-10-12AVON PARK II DEVELOPMENT "^'°"°, °°'°` FINAL SITE PLAN OWNER: STANLEY MARTIN COMPANIES LLC 11710 PLAZA AMERICA DRIVE, SUITE 1100 SDP2021=00049 RESTON, VA 20190 DEVELOPER: STANLEYPLEPLNHOMES E,SUI SCOTTSVILLE DISTRICT - ALBEMARLE COUNTY. VIRGINIA 404 PEOPLE PLACE, SUITE 303 CHARLOTTESWLLE, VA 22911 ENGINEER: COLLINS ENGINEERING 200 GARRETT ST, SUITE K CHARLOTTESWLLE, VA 22902 (434)293-3719 TAX MAP NO.: 090000-00-00-03100 (DB 5237, PG.405) 1960 AVON STREET EXTENDED CHARLOTTESWLLE, VA 22902 TOTAL AREA: 5.262 ACRES ZONING: PRO PLANNED RESIDENTIAL DEVELOPMENT AND ENTRANCE CORRIDOR OVERLAY DISTRICT (ZMA 2012-0004 & ZMA2014-6) A SPECIAL EXCEPTION WAS APPROVED BY THE BOS ON NOVEMBER 4, 2020 (SE202000005). TWO CONDITIONS WERE PART OF THE APPROVAL: 1. ALL VARIATIONS SHALL BE AS DEPICTED ON THE INITIAL SITE PLAN AND SUBDIVISION PLAT FOR AVON PARK Il DEVELOPMENT PREPARED BY COLLINS ENGINEERING AND LAST REVISED ON OCTOBER 5, 2020. w 2. THE APPLICANT SHALL PROWDE LANDSCAPE SCREENING IN ACCORDANCE WITH COUNTY CODE 18-32.7.9.7, OR LANDSCAPING AS APPROVED BY THE AGENT IN THE OPEN Co � CJ SPACE/LANDSCAPING EASEMENT AREAS AS SHOWN ON THE DEPICT70N ENTITLED "INTENSIFIED LANDSCAPING AREA FOR SCREENING CREATED BY THE COMMUNITY 0. DEVELOPMENT DEPARTMENT ON 10-13-20. PROPOSED USE. RESIDENTIAL DEVELOPMENT - TOTAL 30 RESIDENTIAL LOTS 28 SINGLE FAMILY ATTACHED RESIDENTIAL UNITS (TH UNITS) 2 EXISTING SINGLE FAMILY DETACHED RESIDENTIAL UNIT NOTE. (6) OF THE SFA UNITS SHALL BE AFFORDABLE HOUSING UNITS IN ACCORDANCE WITH PROFFER #1. THE (6) UNITS ARE IDEN77FIED WITH AN ASTERISK ON THE SITE PLAN (*). DENSITY.• ALLOWABLE DENSITY PER ZMA APPLICA7ON PLAN: 6 DU/AC TOTAL ALLOWABLE NUMBER OF LOTS: 30 TOTAL LOTS TOTAL NUMBER OF PROPOSED UNITS. • 30 RESIDENTIAL LOTS PROPOSED VARIATIONS A VARIAT70N TO THE APPROVED APPLICA7ON PLAN WAS APPROVED BY THE BOARD OF SUPERVISORS ON NOVEMBER 4, 2020 (SE2020-0005). THE WAIVER SHALL INCLUDE A - - MODIFICATION TO THE LAYOUT FROM THE ORIGINAL APPLICATION PLAN, A MODIFICATION TO N/F ✓ENNIFER L b THE ROADWAY NETWORK (BUT WILL KEEP THE SAME ROADWAY CONNECTIONS), A CERARDI I tl MODIFICATION TO THE SETBACKS (BASED ON THE ROADWAY CHANGES), AND A x x—x-Dgx4q,ryxP4� - x- MODIFICATION TO THE TIMING OF THE INSTALLATION OF THE LANDSCAPING BUFFER AREAS x i AND SCRIM FENCE. oEll x x c F Z I TMP 90E-9 OPEN SPACE.• TOTAL OPEN SPACE PROPOSED = 1.328 AC (25.29) \ w > w'1 N/F DENNIS OR OPEN SPACE A: 6,850 SF f TMP x w LINDA V OCONNOR \N/F ALBEMARLE COUNTY I `y DB 4184 PC 210 OPEN SPACE B.- 50,999 SF f TOTAL OPEN SPACE REQUIRED 259 = 1.316 ACRES �ERVIC6 AUTHORITY x w ( ) BR-3571-PG 2Z2x — OPEN SPACE TO BE OWNED AND MAINTAINED BY THE HOMEOWNERS ASSOCIATION. ALL OPEN x m z SPACE SHALL BE RESERVED IN A DEED FOR THE COMMON USE OF LOT OWNERS IN THE i SUBDIVSION AND NO OPEN SPACE IS PROPOSED TO BE DEDICATED PUBLIC SPACE. BUILDING HEIGHTS. • MAXIMUM BUILDING HEIGHTS SHALL NOT EXCEED 30 FEET I / TMP 90E-7 TMP 90F 8 N/F IAN FARIS N/F ICNACI OR DB 4163 PC 261 TARA L D RECREATIONAL AMENITIES: PER PROFFER 8 THE OWNER SHALL PROI/IDE AND INSTALL A 40 x50, FENCED DOG PARK WITH (2) SMALL BENCHES. IN ADDITION 2 ADDl770NAL PLAY STRUCTURES FOR OLDER p 5 I CHILDREN SHALL BE ADDED IN THE EXISTING TOT LOT AREA ON 7MP090F0-00-00-0OA1 I LOT LOT LOT LOT I OT 26T LOT OWNED BY THE AVON PARK COMMUNITY ASSOCIATION. 4 2 27 r SETBACKS: FRONT. 10' MINIMUM (18' MINIMUM FROM R/W OR EDGE OF SIDEWALK TO GARAGE) SIDE. • NONE - MIN. 10' BUILDING SEPARATION LOT „ REAR: 10' MINIMUM (LOTS 1-4 & 13-28) i 1 5' MINIMUM LOTS 5-12 ( ) r LOT SUBDIVISION STREETS. CURB & GUTTER y y 8 ; h WATERSHED: RIVANNA RIVER DRAINAGE DISTRICT - NOTE.- THIS S17E /S NOT LOCATED WITHIN A PUBLIC WATER SUPPLY RESERVOIR WATERSHED. ti i a LOT 9 ft AGRICUL77)RAL/ FORESTAL DISTRICT. NONE c TOPO &SURVEY. THE BOUNDARY LINE AND PARCEL INFORMATION WAS PROVIDED BY ROUDABUSH, GALE ANDASSOCIATES LOT 10 MAY 2018. THE TOPOGRAPHY INFORMATION IS BASED ON FIELD SURVEY COLLECTED IN MAY 2010. THE PROPERTY IS CURRENTLY BE SURVEYED FOR UPDATED � JTENGINEERING LOT TOPOGRAPHY FOR THE FINAL SITE PLAN. INFORMATION FIELD VERIFIED BY COLLINS 11 LOT L LOT LOT LOT LOT MARCH 2021. I�ILOT 13 14 15 16 17 19 20 LOT DATUM: NAD 83 12'Tt - - . _ - RE sQALz -J— _ 1 _ - L EXISTING VEGETA770N: PARI7ALLY WOODED VV11H (2) RESIDENCES ON 17-IE PROPERTY AND EXISING - ----------- GRAVEL DRIVEWAYS. AREA A: 6,850 SF LIGHTING: NO STREET LIGHTING IS PROPOSED WITH THE DEVELOPMENT. PARKING. PARKING REQUIRED: 2 SPACES PER UNIT + (1 SPACE PER 4 SFA UNITS) 28 SFA UNITS + 2 SFD UNITS = 60 OFF-STREET PARKING SPACES 7 ON-STREET/SURFACE PARKING SPACES TMP 90-30 TOTAL PARKING SPACES REQUIRED: 67 SPACES N/F GARY D BROOKS ✓R DB 4858 PC 406 PARKING SPACES PROVIDED (MINIMUM (1) DRIVEWAY SPACE + (1) GARAGE SPACE): OFF-STREET PARKING SPACES: (2) SPACES PER LOT = 60 SPACES ON-STREET/SURFACE PARKING SPACES PROVIDED FOR GUEST PARKING = 21 SPACES TOTAL PARKING SPACES PROVIDED: 81 TOTAL PARKING SPACES PHASING: THIS PROPERTY SHALL BE DEVELOPED WITHIN 1 PHASE. GRAPHIC SCA E BUILDING SITES: PARCELS 1-30 EACH CONTAIN A BUILDING SITE THAT COMPLIES WITH THE REQUIREMENTS OF 50 0 25 50 100 200 SECT70N 4.2.1 OF THE ALBEMARLE COUNTY ZONING ORDINANCE. BURIAL SITES: NO KNOWN CEMETERIES EXISTS ON THE PROPERTY. ( IN FEET ) 1 inch = 50 ft. STREAM BUFFERS THERE ARE NO WPO 100' STREAM BUFFERS ON THIS PROPERTY. ANY STREAM BUFFER SHALL BE MANAGED IN ACCORDANCE WITH THE ALBEMARLE COUNTY WATER PR07ECT70N ORDINANCE. IMPERVIOUS AREAS. THE TOTAL OVERALL SITE IMPERVIOUS AREA CAN NOT EXCEED 379 PER THE APPROVED ZMA APPLICAT70N PLAN: WETLANDS/STREAMS.- THERE ARE NO WETLANDS OR STREAMS LOCATED ON THE PROPERTY. ROADS. 0.63 AC (PAVED CIRCULATION PARKING AREA = 27,380 SF) FLOODPLAIN: THE PROPERTY LIES IN AN AREA DESIGNATED AS ZONE X AS SHOWN ON THE FLOOD SIDEWALKS. 0.11 AC INSURANCE RATE MAP COMMUNITY PANEL NO.- 51003C0407D, DATED FEBRUARY 4, 2005. BUILDINGS/DRIVEWAYS 1.12 AC TOTAL: 1.86 AC (35.39 IMPERVIOUS AREA) CRITICAL SLOPES THERE ARE PRESERVED SLOPES ON THE PROPERTY. MANAGED SLOPES ARE SHOWN ON THE PROPERTY BASED ON THE ALBEMARLE COUNTY GIS MAPPING FOR THIS PARCEL. THESE PROPOSED USES: LOTS: 127,162 SF (2.919 AC) MANAGED SLOPES ARE SHOWN ON SHEET 2 AND SHEET 4 AND SHALL BE MANAGED IN PRI V ROADS (R/W &PRIVATE ACCESS ESMT): 44,200 SF (1.015 AC) CCES1.J28 ACCORDANCE WITH THE ALBEMARLE COUNTY ZONING REQUIREMENTS. OPEN SPACE. 5 SF AC) RETAINING WALLS: RETAINING WALLS GREATER THAN 36" IN HEIGHT ARE NOT PROPOSED WITH THIS PLAN. OFFSITE EASEMENT ALL PROPOSED GRADING SHALL BE CONSTRUCTED ON SITE OR WITHIN LANDSCAPING STREET TREES ARE PROPOSED ALONG THE NEIGHBORHOOD STREETS IN ACCORDANCE WITH EXISTING RIGHT-OF-WAY. THERE ARE ALSO EXIS77NG OFFSITE ALBEMARLE COUNTY LANDSCAPING REQUIREMENTS WITHIN SECT70N 32.79 OF THE COUNTY EASEMENTS FOR THE ROADWAY AND U77LITY CONNECTIONS TO THE CODE. AVON PARK DEVELOPMENT. IN ADDITIONAL, LANDSCAPING BUFFERS SHALL BE PROVDED ALONG THE BOUNDARY OF THE FIRE FLOW THE EXISTING FIRE FLOW IS 1610 GPM AT 22 PSI PRESSURE. PROPERTY IN ACCORDANCE WITH THE APPROVED APPLICATION PLAN AND PROFFERS. SEE SHEET 3 AND SHEET 16 FOR ADDITIONAL INFORMATION ON THE REQUIRED AND PROPOSED ISO CALCULATIONS: THE MAXIMUM REQUIRED FIRE FLOW FOR THE PROPOSED USE, BASED T H MAXIMUMREQUIRED LANDSCAPING BUFFERS. ALL LANDSCAPING BUFFER AREAS SHALL BE INSTALLED PRIOR TO ISO CALCIS 1100 GPM. THE FIRST CERTIFICATE OF OCCUPANCY. NOTES.- 1) THIS PROPERTY DOES NOT LIE WITHIN AN AGRICULTURAL AND/OR FOREST DISTRICT TRASH: EACH LOT SHALL HAVE AN INDIVIDUAL TRASH CONTAINER TO BE STORED WITHIN THE GARAGE. 2) ONLY (1) DWELLING PER LOT SHALL BE PERMITTED. 3) PROPOSED EASEMENTS SHALL BE DEDICATED TO EITHER PUBLIC OR PRIVATE USE, AS NOTED ON THE STORMWATER MANAGEMENT. ONE UNDERGROUND DETEN770N FACILITY AND A DETEN770N POND ARE PROPOSED WITH SITE PLAN, THE EASEMENTS SHALL BE RECORDED Wl7H SUBDIVISION PLAT. THE DEVELOPMENT TO ACCOMMODATE THE WATER QUANTITY REQUIREMENT FOR THE PROJECT 4) STREET ]REFS SHALL BE PROVIDED ALONG THE PUBLIC STREETS 40' O.C. IN ACCORDANCE WITH WATER QUALITY SHALL ACCOMPLISHED WITH THE PURCHASE OF NUTRIENT CREDITS. VDOT AND ALBEMARLE COUNTY STANDARDS. 5) THIS PROPERTY IS NOT LOCATED WITHIN A DAM INUNDATION ZONE. LEGEND IMP 90E-6 N/F DANEIL SHUMATE DB 4091 PC 534 TMP 90E-Al 77 N/F AVON PARK COMMUNITY ASSOCIATION INC C/O REAL PROPERTY INC DB 3692 PC 319 23 ARM I F--------- 4�----------------- TMP 90-30A L- N/F GARY D OR MYRTLE T BROOKS DB 1191 PC 396 EDGE OF PAVEMENT 0 PEN SPACE AREA B 50,999 LOT 29 40,020 SF 0.92 ACRES CURB PROPOSED ASPHALT PAVEMENT EXISTING VEGETATIVE/LANDSCAPE BUFFER GREEN WAY BUFFER PROPOSED EASEMENT 0 DROP INLET & STRUCTURE NO. DRAINAGE PIPE BENCH MARK 4 VDOT STANDARD STOP SIGN PROPOSED HANDICAP PARKING SPACE « PROPOSED ASPHALT STRIPING 200 EXISTING CONTOUR 200 PROPOSED CONTOUR 0 506.71 TC 506. 21 EP PROPOSED SPOT ELEVATON TBC DENOTES TOP/BACK OF CURB T/B DENOTES TOP OF BOX 506.71 Tw 506.21 ew PROPOSED SPOT ELEVATION TW DENOTES TOP OF WALL BW DENOTES BOTTOM OF WALL PRESERVED STEEP SLOPES MANAGED STEEP SLOPES PEDESTRIAN AND VEHICLE ACCESS PROPOSED CONCRETE PROPOSED & EXISTING GUARDRAIL PROPOSED FENCE OO OO OO OO 100 YR. FLOODPLAIN MILL CREEK VILLAGE c HOMES III VON PARK SITE 4 Y �4 TMP 90-32A N/F ROBERT SPAULS DB 982 PC 365 LOT31 0.83 ACRES DLD VICINITY MAP SCALE: 1" = 2000' 0 OO Sheet List Table Sheet Number Sheet Title 1 COVER SHEET 2 EXISTING CONDITIONS 3 LAYOUT PLAN 4 UTILITY PLAN 5 GRADING AND DRAINAGE PLAN 6 NOTES AND DETAILS 6A NOTES AND DETAILS 7 NOTES AND DETAILS 8 ROAD & WATERLINE PROFILES 9 ROAD PROFILES 10 SANITARY SEWER PROFILES 11 STORM SEWER PROFILES 12 STORM SEWER PROFILES 13 DRAINAGE MAP AND CALCULATIONS 14 DRAINAGE CALCULATIONS 15 SIGHT DISTANCE PROFILES 16 LANDSCAPING PLAN 17 TOTAL NUMBER OF SHEETS APPROVALS DATE DEPARTMENT OF COMMUNITY DEVELOPMENT PLANNER/ZONING ENGINEER INSPECTIONS ARB DEPARTMENT OF FIRE RESCUE ALBEMARLE COUNTY SERVICE AUTHORITY VIRGINIA DEPARMENT OF TRANSPORTATION HEALTH DEPARTMENT Lic. No. 035791 � ``S3 8/26/21 Z4• O�1SI0NAL E MG VF U) Z w U Vl z Z o a o 0 a m w �- U w Z n (n J U Z tJ Z O Q F w U, Z p W L a `LJ r 00 m L9 w N O O') N W N Uj L� —j J J_ U) I I— z LLU U V ® O O N z O Q F w F w w Of U) JOB NO. lit =50' SHEET NO. 1 TH u II III I I \ \ l SCOTT R. LINS'Z U Lic. No. 035791,n 8/26/21 � � �s1ONAL E� w w 1 III II \ ` \V�\`YVII I II 11 1 I 1 I I I I � / / / I / / / I I � \ \ \ I I\ \ I II II I I I I // \\ \ I 11 I I I I 0 j I v A/ V A 1 I 11111�'�v`vv\vvv, v 1 vv I 1 'I I I o u z Z J =O t a K w L V Go w V V I I 1 1 I / \ / �"� w Ln LD z 3 I L s 0 I_-_ D I I IF> 9 � \ I • '\ �\ � \ I I III 11 I 1 I I , I / l � \ i —� l `� � o w a s W Q ' TMPI 0F 1 BU l , I I o CO \ \ O I ry � . %,.a SANITARYSEWER V ` 1V F DAN // I I g I ^I , c� �I/ / / // Ln at �, EASEMENT \ \/ \ \ / 7� pi I q I I 8 X`Y 2 IJTOR' V N' I I / / I / EMENING EXISTINw` 8 1 I DB. 3zgs PG. 6o7 V A \ SH� MA li , / / I I I �' \ �.� _ v DB `�091 P Jby 4/ / / / / / / I I BRICK H�USE ON BASEMENT DB. 3zga PG. 607 I X�X X E/P-E/ 1 zo'GRADING ,�- I I I EASEMENT V ` \ I / B. 24��jj X24'/CONC/RETE ESL / X w V 692 I I EXISTINGIY I DB.3z9z PG. 607 VA \\ \V V I I I G. I 2fh e TMP 90E-7 I I CbMMUNI Y I l V1 � � � P' I � I x3 CO CRET� I I I T� � „ M � I I F/C- /C j i TMP 90E-9 � N/F TAN FARTS SSOCIATION N C O I , � / \ ASCA cy F y ? w o ,� 1 1, TMP 90E-8 I I A i' I II N/F ICNACIO 0 1 DB 4163 PC 261 \ ) l I I 'REAL PROPS T INC l U. 2 0 X 2 1/ S TOY N/ I I � WA I cs, �„ c�, v c=, 10 CONNOR LIVING \ >G NF I / F R ERT .SPA LS l II TAN �� a TRUST \ DB 3ss21P� �1s BJILD N /ONAASE NT / / / 98 G 3 \ X � � w � r TARA L DE I1 v M� y9 I I I I i °' 094 PB 5116 PC 289 CARDENAS P / I I I I1'I�P 90 4A1 I I / I MP 2 \ -- cz, W y v y l I 1 i DB 4060 PG 77 / I I }� I / / O 'Y EMARLE OUNTY o BENCHMARK f F V RlIS t- I I I \ I /] � O 00 / N F Z F �,�i TOP OF MH=67939 1 i / I 1�MI� I `)' ¢ �� S m I I 1 SER CE AU TY X I 'I l �o �o �0 11 n / h II I I � RDB 3571 �C 27 I N i %'� �� / / l / I � > I o II I s / i° �°'° wp� 6 1 0 w p / ID lD I m n N i 6p (op O O° b E9 ♦ sj 1 61 (6$ 6' 4 /// I I I v I n I I I� / 0 0 m m o 1 \ 11 l \ 8p 8 0 0 o y6 66 n6�bbp�y� tD rv¢ 0100 ° o o m I / / y h h n y� N / / / / r v m —9 9� IF e 5 i 6h 0c 0 I m a 1 / o 1 D 0 10 ID , k 1 B 82 / / c0 D I I P� lD CID 58°48'09' E 4.92' 8p I 1 `� °48'07'E 485. 8' ° �31° 2'0 "W 3110' / / F ' GO I 1 P� X x X �� v \ I / 5�°2�5r'E �3�o s' A 1 N29°0s'41 9.00X— X— x X= X x x x� x� x �jA II II Ix I 200 �I / / zoo I II 1 PR PER Y I A\ I �) V I W VEN I 11 LIMIT\p. 1 V A� EXISTING F I CE II I E CE \ II I I I I I 11 1 24 CMP 1 I I I I I , I L9 I 1 1 V A 1 A\ I I I \ TO B RE FF ED I V\ \ I nV I I I 1 11 I 11 1 I 20' D TIL.425 PG.46 N V �S 1 I I I ,I 0) I \ 1 1 \ \ \ I \ (WOVEN RE II I I I I I \ I I I II \ \ \ \ \ / D .423 PG.572 \ \ �\ FENC I I I l I A\ \ \V A rmI O-A \ A A\wE 1 A / (I A V� DB. 561 PG.46 \I A S�6 A V II II CM \5. A \ v v\ B. v V � I f \ \ 1 I � � EXI TIN KEN EL \ EIS NG EN \' \ \ \ \ / 10 X20�RA GE E/llSEME \ \ \� I \\ (V TOE RE OVE 1 1 I T� BE EfVE \ \ \ I \ B.4 PG.462\ I I I icKIwAI \ \ \ \ \Ex koREMAIL / 1 \ \ C\ CONCRETE\ \ tll \\ `\ M I \ V A D . G.572 i ( \\ \\ \ � \\ �\ \ � \ \ I A KENEyCo ¢�N z to I I I I ep I I/ I r I I 1 A\ N �\ vy� A SP ALT \ \I 2 I Io I I I I I I I \ CONC ET I \ �� RE U, \ J \ oil Iz \\ I I I �� \ / ` QtG I Q J O q.Cp \I I \1 �� �\ > 0,VU #I1XISTIIN HCIMETO RE A114 \�\(ON GR TE \ \\ \\ \\ ` \ \ �` / \\\ I 1 1 w Lu 1-0 _ Z _ I V 1 A\ V A � o 00 ID I m^ my G I n_ c cA > O 1� _j I I n h I II I \\ \ \ i I I �\ 1 I i I \n o 0 0 1 0 o m �'� °nv� ^ �" v \I \ W J F— I RAVE I 00 `r P I � IF N MON I x I I 11 I FIN SON D O SELL +0. WOVEN V A\ I I I O w� PI�ANT�R P.O. \ 1 WIFE F NCE OVER \ V o LINE I / I I I I/ 0.281 1 I V A A � Q \ I POP TY LIN \ \ / I \ I I I rP \ I \ J r-i I � � I \ / � I 1 1 1 I/ l i 1 � O Z Z 1 — IF \ \ II °w m� 00 8 9� o / o n o 0 6 * r o of n o ao a` n o w ID v N o 00 IV)— w— v_ o co a a ry o 00 0 1 I I _ \ 1 \ I P \X 1 I Q v \ \ \ \ \ I N, ,69° o� 04i �� 6� —(0� 6I — 0�-0^ 0�—�—�—� —�—�- o —�o - o Ln - 0`�-b�—� — o -� -� —� o 0 0 �ti b� D �� D� o �— o I / I \ / \ I /'� = 1 V \ I �_� ' �� / I I I / 1 / I / \I I WOVEN WIRE i , 1 I ! TMP 90-30 / / � I II II / / / / G / / +�.3 WOVEN / I I / / � N/F CARP D BROOKS JR / / � I I f71P 90-30B D�46sB Pc 4os ERT /// „ / W4 E FENCE OVER \ I I I I r f / j l / N��lo BA1191 PC393BRDDKs / // I �/ � / LU Ln PROPERTY SINE / TMP O-3bA I tl I I I / / / I I I ~ 11 II 1 V 1 / / / , /N/F GAR D OR MYR�'LE BROKSI X \ — / / DB 11 1 PG, 396 N I I I ' I / / / / �/ / / / / I I 1 / U Q LJJ w Z Lu Q CD O I I I I \ EXISTING MANAGED STEEP LOPES N o w 71 / G APHIG' CAE / JOB No. / 112066 °° / / / zo ao / 6 / so% / SCALE / =4 o IN F ET � / // / � SHEET NO. i inch / 40 / , / \ 2 1 LOT AREA TABULATION LOTNUMBER LOTAREA(SF) BUILDABLE AREA (SF) 1 2448 1405 2 1151 911 3 1152 912 4 2169 1427 5 2007 1303 6 1566 1237 7 1568 1237 8 2050 1338 9 1971 1273 10 1541 1211 11 1535 1205 12 1994 1292 13 2509 1713 14 1226 986 15 1226 986 16 2414 1659 17 2301 1567 18 1681 1351 19 1681 1351 20 1222 982 21 1679 1350 22 2297 1560 23 2141 1408 24 1549 1219 25 1130 889 26 1559 1225 27 1559 1229 28 2134 1427 I I I II BUILDING CODE NOTES: 1. ACCESSIBLE PARKING SPACES, ACCESS ISLES, AND ACCESSIBLE ROUTE SHALL BE INSTALLED IN ACCORDANCE WITH ICC ANSI A117.1-og AND THE 2015 VIRGINIA CONSTRUCTION CODE. 2. ALL WATERLINES, SEWER LINES, AND FIRE LINES FROM THE MAIN TO THE STRUCTURE MUST HAVE A VISUAL INSPECTION PERFORMED BY THE BUILDING DEPARTMENT. 3. WHERE THE FLOOD LEVEL RIIMS OF PLUMBING FIXTURES ARE BELOW THE ELEVATION OF THE MANHOLE COVER OF THE NEXT UPSTREAM MANHOLE IN THE PUBLIC SEWER, THE FIXTURE SHALL BE PROTECTED BY A BACKWATER VALVE INSTALLED IN THE BUILDING DRAIN, BRANCH OF THE BUILDING DRAIN, OR HORIZONTAL BRANCH SERVING SUCH FIXTURES. PLUMBING FIXTURES HAVING FLOOD LEVEL RIMS ABOVE THE ELEVATION OF THE MANHOLE COVER OF THE NEXT UPSTREAM MANHOLE IN THE PUBLIC SEWER SHALL NOT DISCHARGE THROUGH A BACKWATER VALVE. 4. ALL ROOF DRAINS SHALL DISCHARGE IN A MANNER NOT TO CAUSE A PUBLIC NUISANCE AND NOT OVER SIDEWALKS. PROPOSED zo' DRAINAGE AND LANDSCAPING EASEMENT (LANDSCAPED BUFFER AREA) DB.PG. - NOTE: IF TREES RE LOCATED WITHIN 5' OR LESS OF THE PROPERTY LINES ADJACEN TO T� �PgoF-A2, TMPgoF�42; TM�Rgoo-F-43, TMPgoF-F-44, T E DEVELOPER SHALL REMOVE THE TREES ON THE ADJACENT PRO ERTIES: THE REMOVAL OF S WILL BE SUBJECT TO TH EXISTING PROPERTY OW ER'S WRI N APPROVAL. ACSA PROPOSED LANDSCAPING WITHIN 15' WATER SCRIM FENCE \ LANDSCAPE BUFFER THAT TANK FENCE ALONG ABUTS ACSA WATER TANK TMP -A2 PROPERTY PROPERTY SHALL HAVE / N/F ALBEMARLE COUNTY LINE SIMILAR LANDSCAPING TO SERVICE AUTHORITY WHAT WAS PLANTED WITH DD13571 PC 279, THE LATEST AVON PARK PROPOSED i5' LANDSCAPING -- STORAGE TANK SECURITY EASEMENT (LANDSCAPED FENCE IMPROVEMENTS PLAN BUFFER AREA) DB.PG. CG 2 COURB - 5' REAR I 0 ?w aWo �01a` a o 0. N C' W�Cn w 2wq O O U � z 0 2 PROPOSED PRIVATE ACCESS EASEMENT DB. PG. 5' REAR SETBAC SIGN (TYP.) WI�■I®II AREA PROPOSED ONSITE LANDSCAPE BUFFER 2o' GRADING EASEMENT DB.3291 PG.607 F/IIt C I ~ IF/C o Lu Ij u z zz 0 �Q 2 rn�i us E V w Z v = l7 kL V PROPO io' w U) LANDSCAPE o z EASEMENT00 j 'z DB._PG._ L' - 2 10 lb -:' 34 LO N 1 8] ~� 5' SIDE SETBACK -Tv1• 5'CONRETE SIDEWALK DESOTO DRIVE o w_s LL 49' PRIVATE R�W N w N LLL� MAILBOX :' E LOT r(TYP.) ll06- 00 KIOSK h� 7 :r 1 rl' 9 70 -- 2' 3 2 16' 1 -n ~? i ' ON S TBA LOT OT 20 N 10 TVP.' 70 - NO PARKING - SIGN (TYP.) 12 l N °. 13 lz' o i n TYP. lELOT w. LOT 70 o LOT LOTIII LOT — _ 3 5 LOT d TRAVE WAYPARKING I / 12-3.' REAR NOTE: 1. SCRIM FENCING TO BE INSTALLED IMMEDIATELY FOLLOWING GRADING IN THE LOCATION WHERE THE SCRIM FENCE IS TO BE LOCATED. 2. THE OFFSITE LANDSCAPING EASEMENT ON TMPgoF-Al (AVON PARK) WAS OFFICIALLY REQUESTED (AS REQUIRED BY THE PROFFERS) AND WAS DENIED BY THE HOA BOARD. 3. SEE SHEET 6 FOR DETAILS AND MEASUREMENTS OF THE FOOTPRINTS OF THE (2) TYPES OF TOWNHOUSE UNITS. 4. THE (6) AFFORDABLE UNITS ARE IDENTIFIED WITH AN ASTERISK N. THE AFFORDABLE UNITS SHALL MEET THE REQUIREMENTS OF PROFFER #1. NOTE: ALL LANDSCAPING EASEMENTS, BUFFERS, AND SCREENING SHALL BE PLANTED IN ACCORDANCE WITH THE APPROVED PROFFERS LANDSCAPING SHALL BE INSTALLED PRIOR TO THE FIRST CERTIFICATE OF OCCUPANCY FOR ANY PROPOSED UNITS WITHIN THE DEVELOPMENT AS DETAILED IN PROFFER �. j I I 2o' GRADING EASEMENT DB.3291 PG.607 I I 1 TMP 90E-9 O' CONNOR LIVING TRUST DB 5116 PG 289 TMP 90E-7 TMP 90E-8 N/F IAN FARIS N/F ICNACIO 0 DB 4163 PG 261 TARA L DE CARDENAS DB 4060 PC 77 PROPOSED SCRIM FENCE FENCE ALONG PROPERTY LINE ADJACENT TO TMP goF-Ai I PROPOSED 2o' DRAINAGE AND LANDSCAPING EASEMENT ) CONC ETE I PROPOSED 2o'LANDSCAPINGEASEMENT -NATURAL y LANDSCAPED AREA OR REPLANTING/NEW -� LANDSCAPED BUFFER FOR ANY DISTURBED AREAS DB.PG. O O CONCRETE LOT 30 \ 37,445 o.86 ACRES THP 90-30B NIF JOHN A OR RUBY T BROOKS DB 1191 PG 396 COMMUNITY ASPHALT ■ O PLANTER MILLING AND OVERLAY FORIMPROVED ASPHALT DRIVEWAY PROVED ASPHALT DRIVEWAY ACCESS FOR (2) LOTS ASSOCIATION INC CIO (LANDSCAPED BUFFER AREA) REAL PROPERTY INC 1 Y y DB. PG. DR .R8.97 PC .R1.9 PROPOSED DRIVEWAY TO BE / I - CG-lz (TYP.) I BRIG _ _ IMPROVED TO AN [-� � � ti I h, �:!' +' I' � ! '. I' •u i, � ,yhiL � I :..::.:::.::.: � ASPHALT DRIVEWAY I w PROPOSED I ;'; '� TO SERVE LOTS 29 I I o u GUARDRAIL AND30 ' I h U DESOTO DRIVE w -f L� PROPOSED VDOTSTD. I LOT 29 3 I I —n n_ V CG-6 CURB 0 020 5� S j 49' PRIVATE RIW w i GR-z I I NOTE: SLOPE OF 4 I EMERGENCY ACCESS 0.92 ACRES I I a 2 ROAD SHALL NOT I I I y�J I EXCEED i6% F— I E-I PROPOSED ', CONCRETE PROPOSED 20' I I 22' 22' 1 2' 0' NO PARKING CG-z CURE ', l EMERGENCY ACCESS 30 z' 16 12 SIGN (TYP.) I A. EASEMENT / o RON ACK MIN.)'' - _ #1968 DB.PG. 1 zo 18 Q m 1 12 �TRAV LWAY PARKING ' I \ PROPOSED iz' /� l j GONC ETE O�tiQ rvP. _ b ASPHALT EMERGENCY d ACCESS ROAD - ::ir: \ s ° LOT LOT LOT *L2OT LOT LOT 22 1:: _ — — — — — — — _ — O p Ov 17 18 1g - J 21 PROPOSED47PRIVATE OR - `�` J— _ _ ,��/ GRAVEL 00 Z I I I I7711 ACCESS EASEMENT \�--- --- J - DB. PG. ---- ----------------- io'REAR"ETBAC' - - - - - - - OPEN `T RP jAREA A: 6SPACE TTREE I \ 85o SF \ �SIOGN TYPNG VAR. WIDTH GRADING AND PROPOSED DOUBLE -SIDED CONSTRUCTION EASEMENT N VERTICAL FENCING (BOARD DB. PG. TMP 90-30 ON BOARD) PRIVACY FENCE F CARY D BROOKS JR SEE DETAIL, SHEET 6 PROPOSED io' LANDSCAPING EASEMENT (LANDSCAPED DB 4858 PC 406 BUFFER AREA) DB PG NOTE: ALL STREETS WITHIN THE DEVELOPMENT SHALL BE MARKED WITH NO PARKING SIGNS ON BOTH SIDES OF THE ROADWAY. PROPOSED CG-6CURB, NO PARKING SIGN(TYPJ N59'18'07"W 1,072.99'(T) PROPOSED io' LANDSCAPING VAR. WIDTH GRADING AND EASEMENT (LANDSCAPED CONSTRUCTION EASEMENT BUFFER AREA) DB. PG. DB. PG. NOTE: (*) DENOTES THE LOCATI N OF THE AFFORDABLE UNIT WITHIN THE DEVELOPMENT. PEP PROFFER #i, THERE SHALL BE (6) AFFORDABLE HOUSING UNITS WITHIN THE DEVELOPMENT. PROPOSED 3 BOARD FARM FENCE ALONG PROPERTY LINE. SEE DETAIL, SHEET 6 TMP 90-30A N/F GARY D OR MYRTLE T BROOKS DB 1191 PG 396 GRAPHIC SCALE ( 1N FEET ) 1 inch = 30 ft. DE 200' CONCRET LOT 30 37�F- o.86 ACRES TMP 90-30B NIF" JOHN A OR RUBY T BROOKS DB 1191 PC 396 Lie. No. 035791,'n 8/26/214i zz w 0 z Z Z J Q k D V Lu O U V w m In = H LD 0 J z � H z O < � F in w in z .. o a �W/ Lu v � Ln 00 ON Lu J ul U) I- Lu U) CD O z J Lu O w In JOB NO. 112066 SCALE 111 =301 SHEET NO. 3 NOTE: INDIVIDUAL PRIVATE DOMESTIC WATER BOOSTER PUMPS SHALL BE PROVIDED IN EACH HOME TO MEET THE MINIMUM WATER PRESSURE REQUIREMENTS. NOTE: PROPOSED STORM SEWER SHOWN IS CLASS III RCP. THE CONTRACTOR MAY SELECT A VDOT APPROVED MATERIAL IN LIEU OF THE CL. III RCP FROM THEIR APPROVED LIST PROVIDED ALL PIPE, PIPE BEDDING, BACKFILL AND INSTALLATIONS ARE IN ACCORDANCE WITH THE CURRENT VDOT STANDARDS. ANY PIPE MATERIAL PROPOSED AS CL. IV RCP SHALL NOT BE SUBSTITUTED WITH ANOTHER PIPE MATERIAL. X X XCIO X X "i 5� rn ACSA d Co -4 CO WATER E, a w CO 't TANK x ��� w� � � mw � `` TMP -A2 N/F ALBEMARLE COUNTY h w q 0. ' \ o DLO 4 SERVICE AUTHORITY x 2 h B 3571 XG 272 14 X PROPOSED TYPE A IF _ BLOW OFF ASSEMBLY S58°48'09"E 114.92' h w 00 �WUo c 0 4 NhC h W M o O Cl) o z O U U � Cy O 2 PROPOSED\ SERVICE LATERAL IF LOT[[ 30 LOT 11 LOT I 12 PROPOSED TYPE AJ VARYING WIDTH - BLOW OFFASSEMBLY PUBLIC UTILITY EASEMENT TMP 90-30 N/F CARY D BROOKS JR DB 4858 PC 406 00 0 0 T ti� I MOM I m. 0 0 +T N PROPOSED 22" DI WATERLINE EXTENSION WITHIN THE PUBLIC R/W TO THE PROPERTY LINE - NOTE: ALL PUBLIC WATER AND SEWER FACILITIES SHALL BE DEDICATED TO THE ALBERMARLE COUNTY SERVICE AUTHORITY REMOVE EXISTING 12"B.O.V. �AN D TIE-IN TO EXISTING DI WATERLINE tI I SANITARY SEWER / EASEMENT III DB. 3291 PG. 607 TMP 90E-9 O'CONNOR LIVING TRUST DB 5116 PG 289 PROPOSED 20' SANITARY SEWER EASEMENTT LOCATION OF SANITARY TI -IN CONNECTION CF °d R'!1 7"C PROPOSED TYPE A BLOW OFF ASSEMBLY TMP 90E-8 N/F IGNACIO 0 TARA L DE CARDENAS DB 4060 PC 77 T-1 — �m a rn LOT 30 37,4�F­ o.86 ACRES O as• I \IMPROVED ASPHALT DRIVEWAY ACCESS FOR (2) LOT \ I I I I I I TMP 90E-7 N/F IAN FARIS DB 4163 PG 261 1H11 U INCEAL PROPERTY NOTE: ALL TH UNITS SHALL HAVE ROOF REAL DRAIN SYSTEMS THAT WILL COLLECT THE DB 3692 PG 319 RUN-OFF AND CHANNEL IT FROM THE ROOFS ROPOSED 8" SANITARY SEWER (TYP.) PF TO THE PROPOSED DRAINAGE SYSTEM. _-S31 °02'03"W 3.10' PROPOSED 25' WATERLINE EASEMENT NOTE: ALL PUBLIC WATERLINE EASEMENTS SHALL BE PLATTED PRIOR TO FINAL SITE PLAN APPROVAL EASEMENT TMP 90-30A N/F CARY D OR MYRTLE T BROOKS DB 1191 PG 396 PROPOSED2o' F++i:":"j:iiiii:':i?;+i?:7?:::ii.?? WATERLINE :::.... `::•.::•.::.::.::.::•.:;.... EASEMENT i:.. r:iii:::i�::i;... r:.. .. : ri.. i::. i::+ii:::::7'.: ?...... i.. c I CONC�ETE I I I GRAPHIC SCALE ( IN FEET ) 1 inch = 30 ft. Lie. No. 035791,E 8/26/214i F- z z w 0 U z Z 0 J Q 0 C) U W � U w � a x ~ U 0 in J z � u z O .a � In w 0 En z .. 0 a �W/ v Lu zl� Ln 00 0) N O Cn N ■. .mom N > \ uJ � J \ u ujL CONCRET L9 _j LOT 30 Q 37,445 bF= o.86 ACRES ci Y 0 00 TMP 90-30B NIF" JOHN A OR RUBY T BROOKS DB 1191 PC 396 i n F- Lu Lu MENEM U) J w J� o z J Lu 0 w a Ln JOB NO. 112066 SCALE 1„ = 30, SHEET NO. 4 0��'f r 10 N�/hh '5�/ �0� A 0pSC�O�TT R. LIN�S�'Z VARIABLE WIDTH�-1 SWM FACILITY CLie. No. 035791� ACCESSEASE ENT 8/26/21 DB. G StoNAi E� V m PROPOSED RIPRAP I OUTFALL INTO ROADSIDE I 1 I I � � ._ •• _ -- OUT ROADSIDE DITCH 25 24" CMP I I I II \ 23� �`� � \ IYPR0 EDASP ALT VDR VEV�/AV I w I I \ A I SWM z rt - \A� E\SS FORI(z) OTS 1 \ V �\ o V � N z � '\ V A Z O Q O - �� v �w LOT 30 y- ^ / V \ V O w __\37� AC �� F�1 vvi 5 LD D 00 ix, 00 \ I 6 N p \ \ 1 O w i0 S I O O .°D ID J/JJ'� zo' GRADING00 _zo' GRADING \ \ \\ \ \ \ I I I �' I/ EASEMENT w I EASEMENT \7� X /X X DB. 3291 PG.607 \ I DB. 3zgi PG.6o7 \ IJ I I / / I Edo _ I\ 692 I I I I II \\ \ 1 I \ I I I it 1 I Ln 00 X\ - v o o I \ TMP 90E-7 P I I A \ PROPOSED io' MAINTENANCEo I & ACCESS RETAINING WALL w a I ! TMP 90E-9 TMP 90E-8 N/F IAN FARIS TMP \ \ r ( I I \ LIVING I DB 4163 PG 261 V / ♦/ II EASEMENT N F ICNACIO 0 \ o w w a / j TRUST d DB.PG. x N �` w TARA L DE w w 0 2 n \ r I DB 5116 PG 289 d rl 694 i CARDENAS / �/! / Cf7 DB NIF A EMARLE OUNTY �� I -' / / / / / ♦ / SER CE AUTHO TY h \ I PROPOSED 8" HDPE ROOF DRAIN SYSTEM I RB 3571 XG 27 \ W/ io' PRIVATE DRAINAGE EASEMENT (� ` PROPOSED 8" HDPE ROOF \ DB. PG. / / - w I NOTE: ALL TH UNITS SHALL HAVE ROOF /° 606 Gov o o q� I DRAIN SYSTEM W/io' PRIVATE e I 6 610 $/� / READ PJ{0lIER Y NCe ` 0 o M 9 DRAINAGE EASEMENT 696\ ss 6g `O O i 666 bbk bbti 6, 6�- �Db j3692 PG3��9 i I RUNDRAT OFF AND CHANNEL N SYSTEMS THAT WILL IT FROM THE ROOFS 1 % \ / N �p o N G Bw 6 6 o i i 6 VARIABLE WIDTH co m m 9� 6 F B. 68 %/ - - ? �O 0y `^ v I I - - SWM FACILITY D ° ° TW 6so Tw sso Tw sd' 13 `68 ? O P� TO THE PROPOSED DRAINAGE SYSTEM. O / �� -� S58°48'09"E 4.92' 4 90 Bw 688 BW 6 48'0TE 485.78' i6 I 31°0 '03" 3. 0' ( , / -/ ACCESS EASEMENT Cr) TW 688 I i Bw j s8 - f 1 m N T 690 8 ! W 3 f w sa --- _ r 3 f D� N O z Cn L N _ :04 1 4 - I I I --- I I i � I LOT I 1 90 II :' :? 1. LFE6 - Bw �, I it ',f:�•:'.. 5 83 - - - r - - - I -- - --- } Q 49 ..--�I I I I ------ � I I LOT I � --- I I :: ;. ;. ;.:: •:. - _ \ 1 I o' LOT LOT r. L T --- 2 C'::';:;::;: ;;:'•':'.,..:::.•... �.. .. ...: }..: ,-tea _=I�.... i Z sso LOT L T LOT * 5 LOT LOT TW * 3 * z LOT z8 z6 z z _ \ ew sa 1 I 1 I 1 - -- - :";:::..:...:.:::::.::::;: .::::::7:7.:::::7;; I I I � I � - IGAR-6 � IGAR-686.1 I I I GAR-68z.00 IGAR-6 8.6 � I !O ^� '� .`` �( '�.... _ _ - - _ --- - �... � LLI W GAR=68.104 -:.::.:.. 3 ;. I I I LOT GAR 6 8.17 I FFE=6 1' 7 I I I I- GA�a-68i.331 FFE=680. 7 I � 71 I o _ AR=6 1 7 FFE=68 8 1 GARr68, FFE=68�.67 FFE=67g.33 I'- L - / /-.6pJ(7 9 7 6/0 FFE-68 8 8 - FFE-68z.00 I -, .i .�I - � 3 I I I IFFE - II _"-� 10 . ; � ...•• _p ,FE=6g1. i\ GAR- 8 8 i� 1 1 GAR=6 g.33 1 6, ,n ..•....:i::/ ,/ / �\ - FFE-67::::: 'iii'::.'i:. {. / B c \-------- w --11 FFE=6 750 I- - 00 1 r a PROPOSED STORM DRAINAGE NAGE ESMT :7::iii.:,.: A .;ii.:.:;::• / / 1 II �3A \ ,\ , ^ 'wn N I LOT I Chi a Y o -- I a --I -- a of - 66 OUTFALL PIPE DB. PG. \ \/ J�.1 ' LLI V' v a 11 AR=6go.go °/e o o o 0 4'?. �'h - J - I i i m ice,- iM i 666 OPEN SPACE \ k boy C0 �5 >ti \ O z 5 \ � z o s �_ ��- \ ' \ I \ - o TW 689 LOT _ 6 - 18 RI K W 22 / 606 I A C�NCRET J H Q \ \ 68 8,., AR=68g.83 zb/o zo' PRIVATE %. : ' : •• • j..•i. -/ , _. •.I j A /.� \ \ \ \ ! j� \ I \ � L.L. w \o FE=6go.5o ` DRAINAGE ESMT L. o � `� I I 1---1 ---- I � ¢ I VARIABLE DESOTO DRIVE ss _ DESOTO DR E N\L �� ` WIDTH SWM ti ) \ \ L \T z9 \ - J� � �am / o FACILITY ti- r,o, Osr 63.0 ~� o.86ACRES `; 06 ET T sa8 r ----- i- - \ ` 4�-RIVATE R W 49' PRI�ATE /W -- O O eo 1 .9z CRE \ I \�� Y ~ - --- _ W BW 68 I _ EASEMENT 2 j LOT ° I, _ - I- 1 2 DB. PG. I \ 6iz : `� z 9 AR=68g.17 245 �... 9 T\ I � \� \ w CONC ET *`°-- r- ° I \ Iw io'IIPRIVA E I \ � � � � � � � w DRAINAGE z1 614 \ Q Q o I ----- y' 01 -o_ ,� - o� % o o� 6 I /\ EASEMENT \ \ I � I I1 •1 I 0.�.10 A �.t Q ij "'o ul 10� LOT J„ m... I'' �I� W 9�,6U AR=68g.17 z o. ..I _ __ _ FE=6go.83 ° 1 I _ 10 IGAR=6 0o U 9 ) �p O N C E V V PROPOSED 8" _ _ 7 (IGAR=6 5.501 'W 68 8 GAR=6 z.z71 11 GA - 8 .83 IGAR=6 8.171 1 V _tl� - 6�8 _ W SYSTEM WIio' L T 12 F ER6 .3311FFE=61T GAR=6 133 7 h> WAR 68. o FFE=68 .81 6 GA FFE=67.83 1 o� HDPE ROOF DRAIN --J -- 171FFE-68 .1 / 4 7 F ER6 FF -61 0 - -I---- - --- --- _ t \ \ -11 - 7 7 8 -I O FFE 6 o 1. allh R=6 g.5ol 1 I- _ 6�. \ I PRIVATE 11 AR=68g. zb/o 4FFE 68 .i .17 1 FF�=6 oa7 \ DRAINAGE - FE-6go.83 LOT 1 LOT L T LOT a - - - r o N 1 U) Q _ -JI� 1 EASEMENT - ----- i LOT 1 LOT 11 i6 LOT LOT LOT u z - - j - N M -�"- N-� i I DB. PG. - - it Ld 18 zo -- -- moo _�- N _� . _ �- ° o-� ° °- `� I -- RAVE LOT TW 687 �I LOT ER'69149 4 J' ' 1 -I ----- I ---1-�i 'IF �A4 -- /-�--- =1 - -_�- I I'. _ --� ---- - f 1 I I I �N I I - 9 3 I� \ l BW 68 L. -1► -- - TW 68 -- -- :ri. i Bw 68a I• _ -- - ---. - --- - - _----- \ Vol \ i ------ -- -- -- ----- ---- - --- ----- -- -- ------ -=-- -- -- P J Q 0 28' :. OPT I � rQn I 1 PROPOSED8" ::::: I N5 '180 'W 1,07 .99'(T O 6 HDPE ROOF DRAIN I o v i 0 SYSTEM W/ io' � I W00 86 / 4 a ry p 0 6 `%" o m N o [O tD .t ry o CO �D v ry o of l0 - d-- rv_ o (p/ '.t ry o a0 l0 V I N �o N PRIVATE ,690 W 0D 00 '� '� �1 •� 1O `0 `O `o- `^ '^ �^ 'n � v v v- v- v m m- \ o 0 0 0�0 To 6I PROPOSED8" - o o - o � - - �o fo w ko to o ko e � b w o co to w kD DRAINAGE / / zo' DRAINAGE I F I \ // HDPE ROOF DRAIN I I I ESMT I \ EASEMENT zo' PUBLIC I DB.PG. DB. PG. �- DRAINAGE ESMT � SYSTEM W/io' � I I I I \ TMP 90-30 DB.PG. / PRIVATE I I I / / T11Plg0-30B I U zo' PUBLIC UTILITY / DRAINAGE I / / / I I I N/F GARY D BROOKS JR ' / / / / EASEMENT 7I ESMT I I I / J / / / D�4858 PC 406 / / { DB. PG. I I / / NSF JOHN OR RIJBBBY T BROODS p w // O i B. PG. / I I I 1 I l I / l DR11191 � 396 a m XISTING MANAGED STEEP SLOPES TO REMAIN \ / TMP 0-3 A �06 No. / NOTE: ALL PUBLIC WATERLINE /N/F GAMY D OR MYRTLE BROOKS I I I I / GRAP�IIC /SCALE I I 112066 \ NOTE: ALL PUBLIC WATER AND SEWER ✓ EASEMENTS SHALL BE PLATTED PRIOR DB 11 1 PG/ 396 I I I 30 I 0 / 0 30 60 /120 - - - FACILITIES SHALL BE DEDICATED TO V� TO FINAL SITE PLAN APPROVAL / / I I I / / SCALE THE ALBERMARLE COUNTY SERVICE _ / a / / / J I II I I I / 1- 30, I I AUTHORITY / / p / / / / J I I I I I ( IN ) EET )� I SHEET NO. / I inch 30 ft. I 5 GENERAL CONSTRUCTION NOTES FOR STREETS 1. CONSTRUCTION INSPECTION OF ALL PROPOSED ROADS WITHIN THE DEVELOPMENT WILL BE MADE BY THE COUNTY. THE CONTRACTOR MUST NOTIFY THE DEPARTMENT OF COMMUNITY DEVELOPMENT (296-5832) 48 HOURS IN ADVANCE OF THE START OF CONSTRUCTION. 2. UPON COMPLETION OF FINE GRADING AND PREPARATION OF THE ROADBED SUBGRADE, THE CONTRACTOR SHALL HAVE CBR TESTS PERFORMED ON THE SUBGRADE SOIL. THREE (3) COPIES OF THE TEST RESULTS SHALL BE SUBMITTED TO THE COUNTY. IF A SUBGRADE SOIL CBR OF 10 OR GREATER IS NOT OBTAINABLE A REVISED PAVEMENT DESIGN SHALL BE MADE BY THE DESIGN ENGINEER AND SUBMITTED WITH THE TEST RESULTS FOR APPROVAL. J. SURFACE DRAINAGE AND PIPE DISCHARGE MUST BE RETAINED WITHIN THE PUBLIC RIGHT-OF-WAY OR WITHIN EASEMENTS PRIOR TO ACCEPTANCE BY THE COUNTY. ALL DRAINAGE OU7FALL EASEMENTS ARE TO BE EXTENDED TO A BOUNDARY LINE OR A NATURAL WATERCOURSE. 4. GUARDRAIL LOCATIONS ARE APPROXIMATE. EXACT LENGTH LOCATION AND APPROPRIATE END TREATMENTS WILL BE FIELD VERIFIED AT THE TIME OF CONSTRUCTION. ADDITI0NAL GUARDRAIL MAY BE REQUIRED AT LOCATIONS NOT SHOWN WHEN, IN THE OPINION OF THE COUNTY ENGINEER, OR DESIGNEE IT IS DEEMED NECESSARY. WHEN GUARDRAIL IS REQUIRED, IT SHALL BE INSTALLED FOUR 4 FEET OFFSET FROM THE EDGE OF PAVEMENT TO THE FACE OF GUARDRAIL, AND ROADWAY SHOULDER WIDTHS SHALL BE INCREASED TO SEVEN (7) FEET. 5. WHERE URBAN CROSS SECTIONS ARE INSTALLED ALL RESIDENTIAL DRIVEWAY ENTRANCES SHALL CONFORM TO VDOT CG-9 A )B OR C . 6. WHERE RURAL CROSS SEC77ONS ARE INSTALLED, ALL RESIDEN7AL DRIVEWAY ENTRANCES SHALL CONFORM TO VDOT STANDARD PE-1. 7. COMPLIANCE WITH THE MINIMUM PAVEMENT WIDTH, SHOULDER WIDTH AND DITCH SECTIONS, AS SHOWN ON THE TYPICAL PAVEMENT SECTION DETAIL, SHALL BE STRICTLY ADHERED TO. 8. ROAD PLAN APPROVAL FOR SUBDIVISIONS IS SUBJECT TO FINAL SUBDIVISION PLAT VALIDATION. SHOULD THE FINAL PLAT FOR THIS PROJECT EXPIRE PRIOR TO SIGNING AND RECORDATION THEN APPROVAL OF THESE PLANS SHALL BE NULL AND VOID. 9. ALL SIGNS OR OTHER REGULATORY DEVICES SHALL CONFORM WITH THE WRGINIA MANUAL FOR UNIFORM TRAFFIC CONTROL DEVICES AND THE ALBEMARLE COUNTY ROAD NAMING AND PROPERTY NUMBERING ORDINANCE AND MANUAL. 10. TRAFFIC CONTROL OR OTHER REGULATORY SIGNS OR BARRICADES SHALL BE INSTALLED BY THE DEVELOPER WHEN IN THE OPINION OF THE COUNTY ENGINEER, OR DESIGNEE, THEY ARE DEEMED NECESSARY IN ORDER TO PROVIDE SAFE AND CONVENIENT ACCESS 11. THE SPEED LIMITS TO BE POSTED ON SPEED LIMIT SIGNS ARE 5 MPH BELOW THE DESIGN SPEED, OR AS DETERMINED BY VDOT FOR PUBLIC ROADS. 12. VDOT STANDARD CD-1 OR CD-2 CROSS -DRAINS UNDER TO BE INSTALLED UNDER THE SUBBASE MATERIAL AT ALL CUT AND FILL TRANSITIONS AND GRADE SAG POINTS AS SHOWN ON THE ROAD PROFILES. 13. A VIDEO CAMERA INSPECTION IS REQUIRED FOR ALL STORM SEWERS AND CULVERTS THAT ARE DEEMED INACCESSIBLE TO VDOT OR COUNTY INSPECTIONS. THE VIDEO INSPECTION SHALL BE CONDUCTED IN ACCORDANCE WITH VDOT'S WDEO CAMERA INSPECTI0N PROCEDURE AND WITH A VDOT OR COUNTY INSPECTOR PRESENT. ROAD NOTES GRADING: 1. THE LATEST EDITION OF THE ROAD & BRIDGE SPECIFICATIONS, THE ROAD & BRIDGE STANDARDS OF THE WRGINIA DEPARTMENT OF TRANSPORTATION SPECIFICATIONS SHALL GOVERN THE MATERIAL AND CONSTRUCT70N METHODS OF THIS PROJECT. 2. WHERE UNSUITABLE MATERIAL IS ENCOUNTERED IN THE ROADWAY, IT SHALL BE REMOVED FROM THE ENTIRE ROAD RIGHT OF WAY WIDTH AND REPLACED WHERE NECESSARY WITH SUITABLE MATERIAL TO THE SATISFACTION OF THE ENGINEER. J. ALL GROWTH OF TREES AND VEGETATION SHALL BE CLEARED AND GRUBBED FOR THE ENTIRE EASEMENT. OTHER TREES AND VEGETATION WHICH OBSTRUCT SIGHT DISTANCES AT ROAD INTERSECTIONS SHALL BE REMOVED. 4. ALL VEGETATION AND OVERBURDEN TO BE REMOVED FROM SHOULDER TO SHOULDER PRIOR TO THE CONSTRUCT70N OF THE SUBGRADE. DRAINAGE 1. ALL PIPE CULVERTS, EXCEPT PRIVATE ENTRANCES, SHOWN HEREON ARE TO BE RCP WITH A MINIMUM COVER OF ONE (1) FOOT 2 STANDARD UNDERDRAINS (CD-1 OR CD-2 OR UD-4'S) TO BE PROVIDED AS INDICATED ON THE PLANS, OR WHERE FIELD COND177ONS INDICATE. J. ALL DRIVEWAY ENTRANCE PIPES SHALL BE A MINIMUM OF TWENTY (20) FEET IN LENGTH AND HAVE A MINIMUM DIAMETER OF FIFTEEN (15) INCHES AND SHALL BE PLACED IN ACCORDANCE WITH THE ORGINIA DEPARTMENT OF TRANSPORTAION SPECIFICATIONS UNLESS OTHERWISE NOTED ON PLANS. 4. ALL DRAINAGE EASEMENT SHALL BE CLEARED AND GRADED TO THE SA7SFACTION OF THE ENGINEER. DRAINAGE EASEMENTS SHALL EXTEND TO A POINT DEEMED AS NATURAL WATER COURSE. PA VEMEN T.- 1. AN ACTUAL COPY OF THE CBR REPORT IS TO BE SUBMITTED PRIOR TO THE PLACEMENT OF THE AGGREGATE BASE MATERIAL. IF THE SSV VALUES ARE LESS THAN 10, THE DEVELOPER WILL BE REQUIRED TO SUBMIT FOR ENGINEERS APPROVAL THE PROPOSED METHOD OF CORRECTION. 2. SUBGRADE MUST BE APPROVED BY THE ENGINEER FOR GRADE, TEMPLATE AND COMPACT70N BEFORE BASE IS PLACED. J. TEST REPORTS ON SELECT MATERIALS MUST BE SUBMITTED SHOWNG THE MATERIAL MEETS REQUIRED GRADAT70N FOR TYPE I, lI, OR Nl PRIOR TO PLACING AGGREGATE BASE. 4. THE REQUIREMENTS TO PUGMILL AGGREGATE BASE WILL BE WAIVED IN THE EVENT THAT THE SURFACE COURSE IS BEGINNING AT THE COMPLETION OF THE INSTALLATION OF THE AGGREGATE BASE. IN THE EVENT THAT THE SURFACE COURSE IS APPLIED PRIOR TO 60 DAYS, THE PUGMILL REQUIREMENT WILL APPLY. ALBEMARLE COUNTY GENERAL CONSTRUCTION NOTES 1. PRIOR TO ANY CONSTRUCT70N WITHIN ANY EXISTING PUBLIC RIGHT-OF-WAY, INCLUDING CONNECT70N TO ANY EXISTING ROAD, A PERMIT SHALL BE OBTAINED FROM THE ORGINIA DEPARTMENT OF TRANSPORTATION (VDOT). THIS PLAN AS DRAWN MAY NOT ACCURATELY REFLECT THE REQUIREMENTS OF THE PERMIT. WHERE ANY DISCREPANCIES OCCUR THE REQUIREMENTS OF THE PERMIT SHALL GOVERN. 2. ALL MATERIALS AND CONSTRUCTION METHODS SHALL CONFORM TO CURRENT SPECIFICATIONS AND STANDARDS OF VDOT UNLESS OTHERWISE NOTED. J. EROSION AND SILTATION CONTROL MEASURES SHALL BE PROVIDED IN ACCORDANCE WITH THE APPROVED EROSION CONTROL PLAN AND SHALL BE INSTALLED PRIOR TO ANY CLEARING GRADING OR OTHER CONSTRUCTION. 4. ALL SLOPES AND DISTURBED AREAS ARE TO BE FERTILIZED, SEEDED, AND MULCHED. 5. THE MAXIMUM ALLOWABLE SLOPE IS 2.1 (HORIZONTAL: VERTICAL). WHERE REASONABLY OBTAINABLE, LESSER SLOPES OF 3: 1 OR BETTER ARE TO BE ACHIEVED. 6. PAVED RIP -RAP OR STABILIZATION MAT LINED DITCH MAY BE REQUIRED WHEN IN THE OPINION OF THE COUNTY ENGINEER, OR DESIGNEE, IT IS DEEMED NECESSARY IN ORDER TO STABILIZE A DRAINAGE CHANNEL. 7. ALL TRAFFIC CONTROL SIGNS SHALL CONFORM KITH THE WRGINIA MANUAL FOR UNIFORM TRAFFIC CONTROL DEVICES 8. UNLESS OTHERWISE NOTED, ALL CONCRETE PIPE SHALL BE REINFORCED CONCRETE PIPE -CLASS Ill. 9. ALL EXCAVATION FOR UNDERGROUND PIPE INSTALLA77ON MUST COMPLY WITH OSHA STANDARDS FOR THE CONSTRUCTION INDUSTRY (29 CFR PART 1926). NOTE: MANDATORY INSPECTIONS AT THE FOLLOWING PHASES ARE REQUIRED FOR ROADS THAT ARE PROPOSED TO BE STATE MAINTAINED: i. INSTALLATION OF ANY ENCLOSED DRAINAGE SYSTEM BEFORE IT IS COVERED. ii. INSTALLATION OF ANY ENCLOSED UTILITY PLACEMENTS WITHIN THE RIGHT-OF-WAY BEFORE BEING COVERED. iii. CONSTRUCTION OF THE CUTS AND FILLS, INCLUDING FIELD DENSITY TESTS, BEFORE PLACEMENT OF ROADBED BASE MATERIALS. iv. A FINAL PAVEMENT DESIGN, BASED ON ACTUAL SOIL CHARACTERISTICS AND CERTIFIED TESTS, SHALL BE COMPLETED AND APPROVED BEFORE THE PAVEMENT STRUCTURE IS PLACED. v. PLACEMENT OF BASE MATERIALS, INCLUDING STONE DEPTHS, CONSISTENT WITH THE APPROVED PAVEMENT DESIGN, PRIOR TO PLACEMENT OF THE PAVING COURSE OR COURSES, FOLLOWED BY FIELD DENSITY AND MOISTURE TESTS AND THE PLACEMENT OF A PAVING COURSE AS SOON AS POSSIBLE. vi. CONSTRUCTION OF PAVEMENT, INCLUDING DEPTH AND DENSITY, UPON COMPLETION AS PART OF THE FINAL INSPECTION. vii. THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING VDOTA MINIMUM OF ONE WEEK PRIOR TO EACH OF THE ABOVE PHASES OF CONSTRUCTION TO SCHEDULE AN INSPECTION. viii. FAILURE OF THE CONTRACTOR TO SCHEDULE THESE INSPECTIONS WILL REQUIRE ADDITIONAL TESTING OF THE ROADS AT THE DISCRETION OF VDOT OR MAY LEAD TO THE ROADS NOT BEING ELIGIBLE FOR STATE MAINTENANCE. TYPICAL ROAD SECTIONS I NTT I NOTES: 1. SEE PAVEMENT DESIGN CHART ON THIS SHEET FOR ROADWAY DEPTH REQUIREMENTS. 2. STREET WIDTHS SHALL BE IN ACCORDANCE WITH ALBEMARLE COUNTY AND FIRE AND RESCUE STANDARDS & WILL PROVIDE ADEQUATE WIDTHS. I 20' REAR SETBACK 24'xg'. - DECKIPATIO 26' II I I I I. 26' x 40' TOWNHOUSE C� I I UNIT R/W R/W 1.5' SM-9.5 CG 6 $ �T DEF EX�GRl //1 v ASPHALT TOPCOAT EXIST. CLO C\ cvRe cuRe 7 ¢ 20'x20' MIN. EMT. GROUND ia5' PLANW SZW GUTTER NAWLWAY FRAMMY � vArcriHc tnriE GUTTER e' �,r� y.� .9a[wAIX EXIST.. GROUND m I GARAGE zr o• o• e• z5' I w - W w 5 R 41, ❑ TYPICAL PUBLIC HATHAJYAY STREET SECTION TYITH PARTYING ON ONE SIDE (55. 5' JYIDTH RO#') I CONC LL 25 .VPH DESIGN SPEED 0 II I NOT TO SCALE . z' z o l 30P1, L5' FRONT-� SETBACK -I 5"CONG S/W <- a TYPICAL 16' TOWNHOUSE UNIT 1 EXIST. GRC EXIST. TYPICAL PRIMATE DESOTO STREET SECTION IYITH NO PARTYING (49' JYIDTH RO#r� 25 MPH DESIGN SPEED NOT TO SCALE TYPICAL PRIVATE AA10AV COURT SECTION IYITH PERPENDICULAR PARTYING (55. 5' T r=ff ROWS 25 MPH DESIGN SPEED NOT TO SCALE W, ---7- OST. GROUND E� I I I 20' REAR SETBACK ------------- I I 26'x20 I I DECK/PATIO I 22' I I I 22'x35 TOWNHOUSE UNIT -I II m iI 20'x20MIN Q GARAGE UJ FI I w O ---------- NC g MIN DRIVEWAY I WIDTH --I I I s I I -- - - - - I 6'.FRONT.. -SETBACK- " 5, CON&SC& - a. TYPICAL 20' TOWNHOUSE UNIT 1 j " SM-9.5A SURFACE COURSE 3" BM-25 INTERMEDIATE COURSE 6" COMPACTED AGGREGATE � BASE COURSE, VDOT #21A °�� o0 0 0 oq OR 21B DEPENDING ON ULTIMATE TRAFFIC LIMITS AND UNDERDRAINS / COMPACTED SUBGRADE ASPHALT PAVING - ROADS NO SCALE PROPOSED 1" SM-9.5 OVERLAY EXISTING PAVEMENT EX. STONE SUBBASE COMPACTED SUBGRADE �IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII ��1111111111111111111111111111 ASPHALT PAVING - MILL/OVERLAY NO SCALE u• PRE u -- TRIP GENERATION SCALE: 1" = 200' TRIP GENERATION CALCULATIONS TRIP GENERATION BASED ON ITE TRIP GENERATION MANUAL (8TH EDITION) TOWNHOME UNITS - CODE 230 ANOKO CT & DESOTO DRIVE (WEST): 16 UNITS PROPOSED SECTION OF HATHAWAY ST.: 28 UNITS ADT: 94 VPD (47 ENTER/ 47 EXIT) ADT: 164 VPD (82 ENTER/ 82 EXIT) AM PEAK: 7 VPH (1 ENTER/ 6 EXIT) AM PEAK: 12 VPH (2 ENTER/ 10 EXIT) PM PEAK: 8 VPH (6 ENTER/ 2 EXIT) PM PEAK: 15 VPH (10 ENTER/ 5 EXIT) DESOTO COURT & DESOTO DRIVE (EAST): 12 UNITS ADT: 34 VPD (17 ENTER/ 17 EXIT) AM PEAK: 5 VPH (1 ENTER/ 4 EXIT) PM PEAK: 6 VPH (4 ENTER/ 2 EXIT) Pavement Design RF= 1.0 Location ADT HCV Design CBR SSV Dr Surface h a Base b a Sub -base h a Dp ADT Hathaway Street 164 5 214 4 4 9.39 SM-9.5 1.5 2.25 BM-25 2.5 2.15 21B 5 0.6 11.75 Desoto Drive, Court & Anoko Court 94 5 144 4 4 8.01 SM-9.5 1.5 2.25 BM-25 2.5 2.15 21A 5 0.6 11.75 Access Road- Asphalt SM-9.5 0 2.25 BM-25 0 2.15 21A 8 106 4.80 3/1G" 5TEEL PLATE WELDED TO P05T & GROUND SMOO' 2-1/2' DIA. GALVANIZED STEEL P05T. PAINTED WITH 2 GOATS OF PRIMER AND INSIGNIA YELLOW 3/4" DIA. 5TEEL PIN W/ HEAD W/ 3/5' DIA. HOLE FOR LOCK FIN15H SURFACE -� 3" DIA. GALVANIZED STEEL PIPE 5LEEVE CPAINT ABOVE GROUND PORTION SAME A5 P05T) CONCRETE FOOTING 3/1G" 5TEEL PLATE WELDEE TO SLEEVE • I i9 12' NOTE: DRILL A 13/IG` DIA. HOLE THRU BOTH THE POST AND SLEEVE FOR PIN PLACEMENT. TYPICAL PRIVATE DESOTO COURT SECTION KITE PERPENTICULAR PARIfING - 47' PRIVATE ROAIJ (PRIVATE ACCESS EASEMENT 25 MPH DESIGN SPEED NOT TO SCALE C7I�{ I S' STONE S BB STSUBBASE @ 2' SAh9.5 ASPHALT TOPCOAT EA7(�GROUND EMST.. GROUND �2'ASP DUMMYDUMMYMYxur Ya' AOMS EASEMENT TYPICAL ASPHALT E.IIERGENCY ACCESS SECTION DRIVL'A'AY SHALL HAVE A 27 SUPERELEV.ATION TO THE EAST NOT TO SCALE ---% ENST. LNG EXIST. GRd1ND O I M 3 BOARD WOODEN FENCE DETAIL NO SCALE DOUBLE -SIDED 6' HIGH WOODEN PRIVACY FENCE NO SCALE ;COTT/R. CbLLINSZ Lic. No. 035791 8/26/21 ,�fj zz w f f O r/ Z Z z J 0 p Q O O O_ k w Da U) W "n z z J U) H z a W O U) z p W a C .. ., Q N N o Ul 00 r N I O N N W O Q on LU U) J w Jrill Q O O N J Q w 0 06 W H z W W d U) 112066 SCALE AS NOTED SHEET NO. 6 1 EXIST. GRC EXIST. TYPICAL PRIMATE DESOTO STREET SECTION IYITH NO PARTYING (49' JYIDTH RO#r� 25 MPH DESIGN SPEED NOT TO SCALE TYPICAL PRIVATE AA10AV COURT SECTION IYITH PERPENDICULAR PARTYING (55. 5' T r=ff ROWS 25 MPH DESIGN SPEED NOT TO SCALE W, ---7- OST. GROUND E� I I I 20' REAR SETBACK ------------- I I 26'x20 I I DECK/PATIO I 22' I I I 22'x35 TOWNHOUSE UNIT -I II m iI 20'x20MIN Q GARAGE UJ FI I w O ---------- NC g MIN DRIVEWAY I WIDTH --I I I s I I -- - - - - I 6'.FRONT.. -SETBACK- " 5, CON&SC& - a. TYPICAL 20' TOWNHOUSE UNIT 1 j " SM-9.5A SURFACE COURSE 3" BM-25 INTERMEDIATE COURSE 6" COMPACTED AGGREGATE � BASE COURSE, VDOT #21A °�� o0 0 0 oq OR 21B DEPENDING ON ULTIMATE TRAFFIC LIMITS AND UNDERDRAINS / COMPACTED SUBGRADE ASPHALT PAVING - ROADS NO SCALE PROPOSED 1" SM-9.5 OVERLAY EXISTING PAVEMENT EX. STONE SUBBASE COMPACTED SUBGRADE �IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII ��1111111111111111111111111111 ASPHALT PAVING - MILL/OVERLAY NO SCALE u• PRE u -- TRIP GENERATION SCALE: 1" = 200' TRIP GENERATION CALCULATIONS TRIP GENERATION BASED ON ITE TRIP GENERATION MANUAL (8TH EDITION) TOWNHOME UNITS - CODE 230 ANOKO CT & DESOTO DRIVE (WEST): 16 UNITS PROPOSED SECTION OF HATHAWAY ST.: 28 UNITS ADT: 94 VPD (47 ENTER/ 47 EXIT) ADT: 164 VPD (82 ENTER/ 82 EXIT) AM PEAK: 7 VPH (1 ENTER/ 6 EXIT) AM PEAK: 12 VPH (2 ENTER/ 10 EXIT) PM PEAK: 8 VPH (6 ENTER/ 2 EXIT) PM PEAK: 15 VPH (10 ENTER/ 5 EXIT) DESOTO COURT & DESOTO DRIVE (EAST): 12 UNITS ADT: 34 VPD (17 ENTER/ 17 EXIT) AM PEAK: 5 VPH (1 ENTER/ 4 EXIT) PM PEAK: 6 VPH (4 ENTER/ 2 EXIT) Pavement Design RF= 1.0 Location ADT HCV Design CBR SSV Dr Surface h a Base b a Sub -base h a Dp ADT Hathaway Street 164 5 214 4 4 9.39 SM-9.5 1.5 2.25 BM-25 2.5 2.15 21B 5 0.6 11.75 Desoto Drive, Court & Anoko Court 94 5 144 4 4 8.01 SM-9.5 1.5 2.25 BM-25 2.5 2.15 21A 5 0.6 11.75 Access Road- Asphalt SM-9.5 0 2.25 BM-25 0 2.15 21A 8 106 4.80 3/1G" 5TEEL PLATE WELDED TO P05T & GROUND SMOO' 2-1/2' DIA. GALVANIZED STEEL P05T. PAINTED WITH 2 GOATS OF PRIMER AND INSIGNIA YELLOW 3/4" DIA. 5TEEL PIN W/ HEAD W/ 3/5' DIA. HOLE FOR LOCK FIN15H SURFACE -� 3" DIA. GALVANIZED STEEL PIPE 5LEEVE CPAINT ABOVE GROUND PORTION SAME A5 P05T) CONCRETE FOOTING 3/1G" 5TEEL PLATE WELDEE TO SLEEVE • I i9 12' NOTE: DRILL A 13/IG` DIA. HOLE THRU BOTH THE POST AND SLEEVE FOR PIN PLACEMENT. TYPICAL PRIVATE DESOTO COURT SECTION KITE PERPENTICULAR PARIfING - 47' PRIVATE ROAIJ (PRIVATE ACCESS EASEMENT 25 MPH DESIGN SPEED NOT TO SCALE C7I�{ I S' STONE S BB STSUBBASE @ 2' SAh9.5 ASPHALT TOPCOAT EA7(�GROUND EMST.. GROUND �2'ASP DUMMYDUMMYMYxur Ya' AOMS EASEMENT TYPICAL ASPHALT E.IIERGENCY ACCESS SECTION DRIVL'A'AY SHALL HAVE A 27 SUPERELEV.ATION TO THE EAST NOT TO SCALE ---% ENST. LNG EXIST. GRd1ND O I M 3 BOARD WOODEN FENCE DETAIL NO SCALE DOUBLE -SIDED 6' HIGH WOODEN PRIVACY FENCE NO SCALE ;COTT/R. CbLLINSZ Lic. No. 035791 8/26/21 ,�fj zz w f f O r/ Z Z z J 0 p Q O O O_ k w Da U) W "n z z J U) H z a W O U) z p W a C .. ., Q N N o Ul 00 r N I O N N W O Q on LU U) J w Jrill Q O O N J Q w 0 06 W H z W W d U) 112066 SCALE AS NOTED SHEET NO. 6 TYPICAL 20' TOWNHOUSE UNIT 1 j " SM-9.5A SURFACE COURSE 3" BM-25 INTERMEDIATE COURSE 6" COMPACTED AGGREGATE � BASE COURSE, VDOT #21A °�� o0 0 0 oq OR 21B DEPENDING ON ULTIMATE TRAFFIC LIMITS AND UNDERDRAINS / COMPACTED SUBGRADE ASPHALT PAVING - ROADS NO SCALE PROPOSED 1" SM-9.5 OVERLAY EXISTING PAVEMENT EX. STONE SUBBASE COMPACTED SUBGRADE �IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII ��1111111111111111111111111111 ASPHALT PAVING - MILL/OVERLAY NO SCALE u• PRE u -- TRIP GENERATION SCALE: 1" = 200' TRIP GENERATION CALCULATIONS TRIP GENERATION BASED ON ITE TRIP GENERATION MANUAL (8TH EDITION) TOWNHOME UNITS - CODE 230 ANOKO CT & DESOTO DRIVE (WEST): 16 UNITS PROPOSED SECTION OF HATHAWAY ST.: 28 UNITS ADT: 94 VPD (47 ENTER/ 47 EXIT) ADT: 164 VPD (82 ENTER/ 82 EXIT) AM PEAK: 7 VPH (1 ENTER/ 6 EXIT) AM PEAK: 12 VPH (2 ENTER/ 10 EXIT) PM PEAK: 8 VPH (6 ENTER/ 2 EXIT) PM PEAK: 15 VPH (10 ENTER/ 5 EXIT) DESOTO COURT & DESOTO DRIVE (EAST): 12 UNITS ADT: 34 VPD (17 ENTER/ 17 EXIT) AM PEAK: 5 VPH (1 ENTER/ 4 EXIT) PM PEAK: 6 VPH (4 ENTER/ 2 EXIT) Pavement Design RF= 1.0 Location ADT HCV Design CBR SSV Dr Surface h a Base b a Sub -base h a Dp ADT Hathaway Street 164 5 214 4 4 9.39 SM-9.5 1.5 2.25 BM-25 2.5 2.15 21B 5 0.6 11.75 Desoto Drive, Court & Anoko Court 94 5 144 4 4 8.01 SM-9.5 1.5 2.25 BM-25 2.5 2.15 21A 5 0.6 11.75 Access Road- Asphalt SM-9.5 0 2.25 BM-25 0 2.15 21A 8 106 4.80 3/1G" 5TEEL PLATE WELDED TO P05T & GROUND SMOO' 2-1/2' DIA. GALVANIZED STEEL P05T. PAINTED WITH 2 GOATS OF PRIMER AND INSIGNIA YELLOW 3/4" DIA. 5TEEL PIN W/ HEAD W/ 3/5' DIA. HOLE FOR LOCK FIN15H SURFACE -� 3" DIA. GALVANIZED STEEL PIPE 5LEEVE CPAINT ABOVE GROUND PORTION SAME A5 P05T) CONCRETE FOOTING 3/1G" 5TEEL PLATE WELDEE TO SLEEVE • I i9 12' NOTE: DRILL A 13/IG` DIA. HOLE THRU BOTH THE POST AND SLEEVE FOR PIN PLACEMENT. TYPICAL PRIVATE DESOTO COURT SECTION KITE PERPENTICULAR PARIfING - 47' PRIVATE ROAIJ (PRIVATE ACCESS EASEMENT 25 MPH DESIGN SPEED NOT TO SCALE C7I�{ I S' STONE S BB STSUBBASE @ 2' SAh9.5 ASPHALT TOPCOAT EA7(�GROUND EMST.. GROUND �2'ASP DUMMYDUMMYMYxur Ya' AOMS EASEMENT TYPICAL ASPHALT E.IIERGENCY ACCESS SECTION DRIVL'A'AY SHALL HAVE A 27 SUPERELEV.ATION TO THE EAST NOT TO SCALE ---% ENST. LNG EXIST. GRd1ND O I M 3 BOARD WOODEN FENCE DETAIL NO SCALE DOUBLE -SIDED 6' HIGH WOODEN PRIVACY FENCE NO SCALE ;COTT/R. CbLLINSZ Lic. No. 035791 8/26/21 ,�fj zz w f f O r/ Z Z z J 0 p Q O O O_ k w Da U) W "n z z J U) H z a W O U) z p W a C .. ., Q N N o Ul 00 r N I O N N W O Q on LU U) J w Jrill Q O O N J Q w 0 06 W H z W W d U) 112066 SCALE AS NOTED SHEET NO. 6 ASPHALT PAVING - MILL/OVERLAY NO SCALE u• PRE u -- TRIP GENERATION SCALE: 1" = 200' TRIP GENERATION CALCULATIONS TRIP GENERATION BASED ON ITE TRIP GENERATION MANUAL (8TH EDITION) TOWNHOME UNITS - CODE 230 ANOKO CT & DESOTO DRIVE (WEST): 16 UNITS PROPOSED SECTION OF HATHAWAY ST.: 28 UNITS ADT: 94 VPD (47 ENTER/ 47 EXIT) ADT: 164 VPD (82 ENTER/ 82 EXIT) AM PEAK: 7 VPH (1 ENTER/ 6 EXIT) AM PEAK: 12 VPH (2 ENTER/ 10 EXIT) PM PEAK: 8 VPH (6 ENTER/ 2 EXIT) PM PEAK: 15 VPH (10 ENTER/ 5 EXIT) DESOTO COURT & DESOTO DRIVE (EAST): 12 UNITS ADT: 34 VPD (17 ENTER/ 17 EXIT) AM PEAK: 5 VPH (1 ENTER/ 4 EXIT) PM PEAK: 6 VPH (4 ENTER/ 2 EXIT) Pavement Design RF= 1.0 Location ADT HCV Design CBR SSV Dr Surface h a Base b a Sub -base h a Dp ADT Hathaway Street 164 5 214 4 4 9.39 SM-9.5 1.5 2.25 BM-25 2.5 2.15 21B 5 0.6 11.75 Desoto Drive, Court & Anoko Court 94 5 144 4 4 8.01 SM-9.5 1.5 2.25 BM-25 2.5 2.15 21A 5 0.6 11.75 Access Road- Asphalt SM-9.5 0 2.25 BM-25 0 2.15 21A 8 106 4.80 3/1G" 5TEEL PLATE WELDED TO P05T & GROUND SMOO' 2-1/2' DIA. GALVANIZED STEEL P05T. PAINTED WITH 2 GOATS OF PRIMER AND INSIGNIA YELLOW 3/4" DIA. 5TEEL PIN W/ HEAD W/ 3/5' DIA. HOLE FOR LOCK FIN15H SURFACE -� 3" DIA. GALVANIZED STEEL PIPE 5LEEVE CPAINT ABOVE GROUND PORTION SAME A5 P05T) CONCRETE FOOTING 3/1G" 5TEEL PLATE WELDEE TO SLEEVE • I i9 12' NOTE: DRILL A 13/IG` DIA. HOLE THRU BOTH THE POST AND SLEEVE FOR PIN PLACEMENT. TYPICAL PRIVATE DESOTO COURT SECTION KITE PERPENTICULAR PARIfING - 47' PRIVATE ROAIJ (PRIVATE ACCESS EASEMENT 25 MPH DESIGN SPEED NOT TO SCALE C7I�{ I S' STONE S BB STSUBBASE @ 2' SAh9.5 ASPHALT TOPCOAT EA7(�GROUND EMST.. GROUND �2'ASP DUMMYDUMMYMYxur Ya' AOMS EASEMENT TYPICAL ASPHALT E.IIERGENCY ACCESS SECTION DRIVL'A'AY SHALL HAVE A 27 SUPERELEV.ATION TO THE EAST NOT TO SCALE ---% ENST. LNG EXIST. GRd1ND O I M 3 BOARD WOODEN FENCE DETAIL NO SCALE DOUBLE -SIDED 6' HIGH WOODEN PRIVACY FENCE NO SCALE ;COTT/R. CbLLINSZ Lic. No. 035791 8/26/21 ,�fj zz w f f O r/ Z Z z J 0 p Q O O O_ k w Da U) W "n z z J U) H z a W O U) z p W a C .. ., Q N N o Ul 00 r N I O N N W O Q on LU U) J w Jrill Q O O N J Q w 0 06 W H z W W d U) 112066 SCALE AS NOTED SHEET NO. 6 3/1G" 5TEEL PLATE WELDED TO P05T & GROUND SMOO' 2-1/2' DIA. GALVANIZED STEEL P05T. PAINTED WITH 2 GOATS OF PRIMER AND INSIGNIA YELLOW 3/4" DIA. 5TEEL PIN W/ HEAD W/ 3/5' DIA. HOLE FOR LOCK FIN15H SURFACE -� 3" DIA. GALVANIZED STEEL PIPE 5LEEVE CPAINT ABOVE GROUND PORTION SAME A5 P05T) CONCRETE FOOTING 3/1G" 5TEEL PLATE WELDEE TO SLEEVE • I i9 12' NOTE: DRILL A 13/IG` DIA. HOLE THRU BOTH THE POST AND SLEEVE FOR PIN PLACEMENT. TYPICAL PRIVATE DESOTO COURT SECTION KITE PERPENTICULAR PARIfING - 47' PRIVATE ROAIJ (PRIVATE ACCESS EASEMENT 25 MPH DESIGN SPEED NOT TO SCALE C7I�{ I S' STONE S BB STSUBBASE @ 2' SAh9.5 ASPHALT TOPCOAT EA7(�GROUND EMST.. GROUND �2'ASP DUMMYDUMMYMYxur Ya' AOMS EASEMENT TYPICAL ASPHALT E.IIERGENCY ACCESS SECTION DRIVL'A'AY SHALL HAVE A 27 SUPERELEV.ATION TO THE EAST NOT TO SCALE ---% ENST. LNG EXIST. GRd1ND O I M 3 BOARD WOODEN FENCE DETAIL NO SCALE DOUBLE -SIDED 6' HIGH WOODEN PRIVACY FENCE NO SCALE ;COTT/R. CbLLINSZ Lic. No. 035791 8/26/21 ,�fj zz w f f O r/ Z Z z J 0 p Q O O O_ k w Da U) W "n z z J U) H z a W O U) z p W a C .. ., Q N N o Ul 00 r N I O N N W O Q on LU U) J w Jrill Q O O N J Q w 0 06 W H z W W d U) 112066 SCALE AS NOTED SHEET NO. 6 .. ., Q N N o Ul 00 r N I O N N W O Q on LU U) J w Jrill Q O O N J Q w 0 06 W H z W W d U) 112066 SCALE AS NOTED SHEET NO. 6 CC-9D EXISTING OR PROPOSED SIDEWALK OR SIDEWALK SPACE EXPANSION JOINT A eO EXPANSION JOINT C D C J M " PEDESTRIAN ACCESS ROUTE DETAILS WITH & FLOW LINE z WITHOUT UPAVED SPACE a w ENTRANCE WIDTH ADDITIONAL RIGHT-OF-WAY IS IF THE LIMITS 1'-3" F 3 DESIRABLE MINIMUM 16' EXPANSION JOINT ABSOLUTE MINIMUM 12' TEOVIRED OF PROPOSED AGGE55 ROUTE EXTEND BEYOND OR PROPOSED VDOT RIGHT -OF W EXISTING 15" EDGE OF PAVEMENTiv ® PEDESTRIAN ACCESS ROUTES PROVIDE A CONTINUOUS UNOBSTRUCTED, STABLE, FIRM AND SLIP RESISTANT . s, • �. , A PATH CONNECTING ALL ACCESSIBLE ELEMENTS OF A HALF PLAN FACILITY THAT CAN BE APPROACHED. ENTERED AND e. • �. • �• USED BY PEDESTRIANS. e•e e �e•e•o.o 1R IF PEDESTRIAN ACCESS ROUTES N ARE BEING PROVIREQUIRED WITH MINIMUM CROSS ARSLOPE. DTH IS SECTIONoB-B WHEN USED IN CONJUNCTION WITH STANDARD OR CG-7, THE CURB FACE ON THIS y'-p•• STANDARD IS TO BE ADJUSTED TO MATCH STAIN UNPAVED i SIDEWALK SPACE ABOLIC THE MOUNTABLE CURB CONFIGURATION. SPACE n NORMAL GUTTER ® _�- --CETrURV:E x xs. •4. '6• e' 'n• I e.e•e •e.e edo 0• a�e'•4o'ba4orx�4g4 eSo d4'4'e gFOX 70 %)X CHANGE •?e ee. aoo.ee 4 4 4o b 6" SECTION C-C GGR EGGAA A 6" AGGREGATE BASE CLASS A3 (LES.I CONIC. TYPE )SIZE 21B 2•.0'• S A POINT OF GRADE CHANGE I� 12% MAX.%. SLOPE FOR CURB AND GUTTER ONLY iIF • e. • N. . p• z x 12 X MAXIMUM INCREASE IN SLOPE AT MINIMUM 10' INTERVAL$ , G FOR SIDEWALK CURB AND CUTTER x x x 3 % MAXIMUM DECREASE IN SLOPE FOR FIRST IVINTERVAL AND 's• BUILT CONCURRENTLY 8 % MAXIMUM DECREASE FOR SUCCEEDING MINIMUM 10' INTERVALS •o,ee ee oe ee SECTION A -A SECTION D-D XV00 STANDARD ENTRANCE GUTTER SPECIFICATION REFERENCE ROAD AND BRIDGE STANDARDS SHEET 1 OF 1 REVISION DATE 502 203.03 07/15 VIRGINIA DEPARTMENT OF TRANSPORTATION GR-2, 2A X 27-Y4" MIN - 28-Y4" MAX RAIL HEIGHT 6'-3" X GR-2 (II POST SPACING) MAX DYNAMIC DEFLECTION - 3' NOTES: GUARDRAIL LOCATIONS SHOWN ON PLANS ARE APPROXIMATE ONLY AND CAN BE ADJUSTED DURING CONSTRUCTION F AND AS DIRECTED BY THE ENGINEER. FOR DETAILS OF POST AND BLOCKOUTS SEE SHEET NO. 501.05 FOR DETAILS OF RAIL ELEMENT, RAIL SPLICE JOINT, AND ASSOCIATED HARDWARE SEE SHEET NOS. 501,01 AND 501,02, RAIL ELEMENTS ARE FURNISHED SHOP CURVED FOR RADII BETWEEN 5 FEET AND 15C FEET. ALL GUARDRAIL PDSTS SHALL BE SET PLUMB. POST SHALL NOT BE SET WITH A VARIATION OF MORE THAN/g" PER FOOT FROM VERTICAL. W-BEAM, BLOCKOUTS, AND POSTS SHALL BE SET AND ALIGNED WITHOUT ALTERATION OR FORCE, AS PER SECTION 505 OF THE SPECIFICATIONS. HEIGH i OFA27)'a'RM?N R28'yxHALL MAXBASMMEASURED PER STANDARD GRANS. ALL W-BEAM RAILS SHALL BE LAPPED IN THE DIRECTION OF VEHICULAR TRAVEL FOR THE FINISHED ROADWAY. THE OPTIONAL GI METHODS OF NESTING THE RAIL OR USE OF AN ADDITIONAL RAIL CN THE BACK OF THE POST FOR STANDARD OR-2A SHALL BE APPROVED BY THE ENGINEER PRIOR TO INSTALLATION. N-11/2' 3'-IVz" 1�9.t�JA1.t1' IAtYAYl.Y !q�lA"l.J7aT rWn III GR-2A C3'-1%2' POST SPACING) MAX DYNAMIC DEFLECTION 2' Eff T x OPTIONAL GR-2A METHOD x OPTIONAL GR-2A METHOD USING NESTED RAIL USING ADDITIONAL RAIL ON BACK OF POST x WHEN NESTED RAIL OR ADDITIONAL RAIL IS PLACED ON BACK OF POST FOR GR-2A THE POST SPACING WILL BE W-3". FLARE RATES DESIGN SPEED INSIDE SHY LINE BEYOND SHY LINE MPH SHY LINE LS FLARE I RATE FLARE RATE 70 9' 30-1 15:1 * 60 B. 26-1 14:1 • 50 6.5' 21:1 11:1 • 40 5' 16:1 8:1 • 30 4' 13:1 7:1 • • SUGGESTED MAXIMUM FLARE RATE FOR SEW -RIGID BARRIER SYSTEMS. ,VDOT A COPY OF THE ORIGINAL SEALED AND SIGNED DRAWING IS ON FILE IN THE CENTRAL OFFICE. SPECIFICATION ROAD AND BRIDGE STANDARDS STANDARD BLOCKED -OUT W-BEAM GUARDRAIL REFERENCE SHEET 1 OF 2 REVISION DATE (STRONG POST SYSTEM) sols 50104 08/14 VIRGINIA DEPARTMENT OF TRANSPORTATION M 1100% OF 4 2" R CURB 4 ,a 1 a 4, - 1. elf 6.. 2' STANDARD CG-6 CURB & GU TTER NO SCALE f (VARIABLE WIDTH) 7' 1 4" CONC. 3000 psi MIN. VDOT #57,#68, OR #78 STONE BASE UNDER CURB & CHECKED BY VDOT PRIOR TO PAVING AND/OR BACKFILLING. CG-12 NOTE: COMPONENTS OF CURB RAMPS CONSIST OF THE FOLLOWING: HYDRAULIC CEMENT SIDEWALK (DEPTH IN INCHES, AREA IN SQUARE YARDS) GENERAL NOTES CURB WHEN REQUIRED (CG-2 R CG-3 IN LINEAR FEET) WARNING SURFACE (AREA IN SQUARE YARDS) 1. THE DETECTABLE WARNING SHALL BE PROVIDED BY TRUNCATED DOMES. EACH OF THE ABOVE ITEMS IS A SEPARATE PAY ITEM AND SHOULD BE SUMMARIZED FOR EACH CURB CUT RAMP. 2. DETECTABLE WARNING SHALL BE FROM THE MATERIALS APPROVED LIST FOR DETECTABLE WARNING SUFACES. PRODUCTS NOT LISTED SHALL MEET SIDEWALK RAMP 12�1 MAX THE REQUIREMENTS OF THE SPECIAL PROVISION FOR CG-12 DETECTABLE 48�1 MAX WARNING SURFACE AND SHALL BE SUBMITTED TO THE STANDARDS AND SPECIAL DESIGN SECTION FOR APPROVAL. 3. SLOPING SIDES OF CURB RAMP MAY BE POURED MONOLITHICALLY WITH RAMP q• FLOOR OR BY USING PERMISSIBLE CONSTRUCTION JOINT WITH REQUIRED BARS. 8 4. IF RAMP FLOOR IS PRECAST, HOLES MUST BE PROVIDED FOR DOWEL BARS SO MAX THAT ADJOINING FLARED SIDES CAN BE CAST IN PLACE AFTER PLACEMENT OF 10:1 PRECAST RAMP FLOOR. PRECAST CONCRETE SHALL BE CLASS A-4. TYPE A 5. REQUIRED BARS ARE TO BE NO. 5 X 8" PLACED T CENTER TO CENTER ALONG PERPENDICULAR BOTH SIDES OF THE RAMP FLOOR, MID -DEPTH OF RAMP FLOOR. MINIMUM CONCRETE COVER 1V2". ` 6. CURB / CURB AND GUTTER SLOPE TRANSITIONS ADJACENT TO CURB RAMPS ARE INCLUDED IN PAYMENT FOR CURB / CURB AND GUTTER. 5'MIN 7. CURB RAMPS ARE TO BE LOCATED AS SHOWN ON THE PLANS OR AS DIRECTED 12 o T BY THE ENGINEER. THEY ARE TO BE PROVIDED AT INTERSECTIONS WHEREVER 12;1 MAX S AN ACCESSIBLE ROUTE WITHIN THE RIGHT OF WAY OF A HIGHWAY FACILITY CROSSES A CURB REGARDLESS OF WHETHER SIDEWALK IS EXISTING, PROPOSED, OR NONEXISTENT. THEY MUST BE LOCATED WITHIN PEDESTRIAN CROSSWALKS AS SHOWN ON PLANS OR AS DIRECTED BY THE ENGINEER, AND SHOULD NOT TYPE B BE LOCATED BEHIND VEHICLE STOP LINES, EXISTING LIGHT POLES, FIRE PARALLEL HYDRANTS, DROP INLETS, ETC. ACCESSIBLE ROUTES PROVIDE A CONTINUOUS UNOBSTRUCTED, STABLE, FIRM AND SLIP RESISTANT PATH CONNECTING ALL ACCESSIBLE ELEMENTS OF A FACILITY THAT CAN BE APPROACHED, ENTERED AND USED BY PEDESTRIANS. B. RAMPS MAY BE PLACED ON RADIAL OR TANGENTIAL SECTIONS PROVIDED THAT 1 THE CURB OPENING IS PLACED WITHIN THE LIMITS OF THE CROSSWALK AND THAT THE SLOPE AT THE CONNECTION OF THE CURB OPENING IS PERPENDICULAR TO THE CURB. 5'MN ;;SAT 9. TYPICAL CONCRETE SIDEWALK IS 4" THICK. WHEN THE ENTRANCE RADII CANNOT ACCOMMODATE THE TURNING REQUIREMENTS OF ANTICIPATED HEAVY TRUCK 4' M1NT TRAFFIC, REFER TO STANDARD CC-13, COMMERCIAL ENTRANCE (HEAVY )K 2" HIGHER THAN TRUCK TRAFFIC) FOR CONCRETE DEPTH. , EDGE OF PAVEMENT 10. WHEN CURB RAMPS ARE USED IN CONJUNCTION WITH A SHARED USE PATH, \ \ AT XX . SAME AS TOP OF CURB THE MINIMUM WIDTH SHALL BE THE WIDTH OF THE SHARED USE PATH. 11 H v P PROVIDED F T WHEN ONLY ONE CURB RPM S ROV DED OR TWO CROSSINGS (DIAGONAL). TYPE C A 4' x 4' LANDING AREA SHALL BE PROVIDED TO MANEUVER A WHEELCHAIR PARALLEL & PERPENDICULAR INTO THE CROSSWALK WITHOUT GOING INTO THE TRAVELWAY. THIS 4' x 4' LANDING AREA MAY INCLUDE THE GUTTER PAN. 12. ALL CASES WHERE CURB RAMPS INTERSECT A RADIAL SECTION OF TRUNCATED DOME Cn C-C m CURB AT ENTRANCES OR STREET CONNECTIONS THE DETECTABLE .6"-2.4" -� o WARNING SURFACE SHALL HAVE A FACTORY RADIUS OR BE FIELD 0 0 0 0 0 0 z -MODIFIED AS RECOMMENDED BY THE MANUFACTURER TO MATCH (b THE BACK OF CURB. - 0 0 0 0 0 0 0 0 0 0 0 0 - O O O O O 0 0 0 O O O O TT LANDING RAMP + 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 l a a 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 N 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 IR 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5OX-651. OF BASE DIAMETER 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOP DIAMETER DETECTABLE WARNING o AT BACK OF CURB _ 0.9"-1.4" I VARIABLE FULL WIDTH OF RAMP FLOOR SEE NOTE 12. F- BASE DIAMETER _ _ r PAY LIMITS DETECTABLE WARNING TRUNCATED DOME INSTALLED ON A RADIUS DETAIL DETECTABLE WARNING DETAIL 1V❑oT SPECIFICATION CG-12 DETECTABLE WARNING SURFACE REFERENCE ROAD AND BRIDGE STANDARDS SHEET 1 OF 5 REVISION DATE (GENERAL NOTES) 105 203.05 01/15 VIRGINIA DEPARTMENT OF TRANSPORTATION 502 02A n all 6•, � 1�i, WASHER -�R�-2, I 9 Ia I - % z L -- -_ f Yx„ HOLE �i" HOLE a & NUT -- 6"x Wxi'-2" TREATED 6 x6 x1-2 �'d' HOLE J PINE BLOCK OR 0 RECYCLED MATERIAL. TREATED PINE BLOCK OR 3 <E RECYCLED GALV. STEEL 10D o MATERIAL COMMON NAIL w SEE NOTE 5. w 6" WIDE BLOCKOUT FOR USE WHEN REPAIRING DAMAGED GUARDRAIL 6"z8"zt'-2" TREATED - CONTAINING STEEL BLOCKOUTS. PINE BLOCK z 0 BLOCKOUT FOR MAINTENANCE TREATED 71" REPAIR ONLY SOUTHERN PINE �9 I v 7Y4" LESS THAN 1'-0" %" HOLE 6x8 WOOD POST 5 4"x 8"xi'-2" TREATED , PINE BLOCK. STRONG POST THE CRT POST IS FOR USE WITH THE 4" WIDE BLOCKOUT 8' 0" POST GUARDRAIL REQUIRED STANDARD GR-10 TYPE IIIOR WHERE STFfpFR BY THE ENGINEER IN THE PLANS.IED Ty DETAIL A 4, Yn" DIA POST MAY BE HOT ROLLED OR WELDED. HOLE v GUARDRAIL INSTALLATION -- r�bLes SITES REQUIRING LONGER II GUARDRAIL POSTS 3 Aool' 6xB"x1'-2" TREATED PINE w 1. ALL BOLTS, NUTS, WASHERS, AND OTHER i &NUT BLOCK OR o STEEL ITEMS ARE TO BE GALVANIZED. _ -IIE ow II RECYCLED w MATERIAL w 2. ALTERNATE TYPE POSTS AND BLOCKOUT MAY l v it 1= BE INTERANGED ONER WITH II W6x8.5 OR z THE RESTRICTION0ATANTHE SAMEY TYPET OF W6x9 g POST AND BLOCKOUT MUST BE USED IN ANY II SINGLE RUN OF GUARDRAIL. - II - -_ - It OPTIONAL HOLE t° 3. FOR DETAILS OF GUARDRAIL ELEMENT SPLICE II TO FACILITATE I GALVANIZING JOINT, HARDWARE, ETC. SEE SHEET NOS. 501.01 AND 501.02. 3Vz' DIAL HOLES ,1 IIIJ/-Ir q 4. DRIVE NAIL ON BOTH SIDES WITHIN 2" OF THE TOP OR BOTTOM OF BLOCKOUT AFTER I%" x 18 BOLT IS INSTALLED. HOLES IN POSTS g•' � � � AND BRACKETS TO BE Y4' DNA. CRT POST STEEL POST SPECIFICATION A COPY OF THE ORIGINAL SEALED AND SIGNED DRAWING IS ON FILE IN THE CENTRAL OFFICE. XVD❑T REFERENCE STANDARD BLOCKED -OUT W-BEAM GUARDRAIL ROAD AND BRIDGE STANDARDS 2316 (STRONG POST SYSTEM, POST AND BLOCKOUT DETAILS) REVISION DATE SHEET 2 OF 2 505 VIRGINIA DEPARTMENT OF TRANSPORTATION 08/14 501.05 �-- 4" 21-A STONE BASE CONCRETE SIDEWALK NO SCALE Tree Planting and Staking Detail Not To Scale DOUBLE STRAND #12 GAUGE WIRE WITH RUBBER HOSE & TURNBUCKLES 2'x2' HARDWOOD STAKE CUT & REMOVE BURLAP FROM TOP 1/3 OF BALL AS SHOWN SCARIFY SUBSOIL TO 4• MIN. DEPTH MULCH SAUCER FINISHED GRADE TREES UP TO 4" CAL. SHALL BE STAKED. TREES 4' CAL. OR LARGER SHALL BE GUYED WITH 3 EQUALLY SPACED TWISTED, #12 GAUGE WIRE WITH HOSE AND TURNBUCKLES. LOOP HOSE AROUND TRUNK ABOVE BRANCHES AS SHOWN, FLAG WIRES WITH COURVEY TAPE. REFER TO SPECS FOR ADDITIONAL INFORMATION. AMENDED SOIL MIX COMPACTED SUBGRADE EXISTING OR PROPOSED SIDEWALK OR SIDEWALK SPACE F EXPANSION JOINT C I<-] WIDTH OF ENTRANCE EXPANSION JOINT d O F " 0.. w i ¢ J f w g qE J U w CURB INCLUDED IN I� ENTRANCE CUTTER = W z A Q W W 0 s FLOW LINE W m F ENTRANCE WIDTH EXPANSION JOINT DESIRABLE MINIMUM 16' c ABSOLUTE MINIMUM 12' 3 EDGE OF PAVEMENT iv C HALF PLAN WIDTH OF CC-9B ENTRANCE El t LIMITS OF PED. LIMITS OF PED. ACCESS ROUTE ® o ACCESS ROUTE UNPAVED SPACE NON -TRAVERSABLE -' UNPAVED SPACE WIDTH OF ENTRANCE LIMIT$ OF PED. - LIMTS OF PED. LESS ROUTE ® : NON-TRAVERSABLEMOPE ACCESS ROVTE PEDESTRIAN ACCESS ROUTE DETAIL WITH & WITHOUT UNPAVED SPACE ADDITIONAL RIGHT-OF-WAY IS RE RED IF THE LIMITS OF PEDESTRIAN ACCESS ROUTE EXTEND BEYOND EXISTING OR PROPOSED VDOT HT -OF WAY. RI 1 I ® PEDESTRIAN ACCESS ROUTES PROVIDE A CONTINUOUS - �• ' �' n. UNOBSTRUCTED, STABLE, FIRM AND SLIP RESISTANT PATH CONNECTING ALL ACCESSIBLE ELEMENTS OF A o . o . o • o oe �ogoq •o FACILITY THAT CAN BE APPROACHED, ENTERED MIND eo USED BY PEDESTRIANS. IF ACCESS ROUTE IS ADJACENT TO BACK OF CURB, MINIMUM WIDTH SHOULD BE 6'. SECTION F-F )E IF PEDESTRIAN ACCESS ROUTES ARE BEING PROVIDED, A MINIMUM 4' TRAVERSRM LE WIDTH IS REQUIRED WITH A MAX. 27. CROSS SLOPE. - c. WHEN USED IN CONJUNCTION WITH STANDARD PARABOLIC CG-3 OR CG-7 THE CURB FACE ON THIS PTO UNPAVED SIDEWALK URVERABO STANDARD IS BE ADJUSTED TO MATCH THE o •e • e • o MOUNTABLE CURB CONFIGURATION. NORMAL GUTTER ® ® ------ ® SECTION E-E • o.� e, - c. • ti. . N. • �. • 6. • �. ' Nc• •be•4.4b:e x *OX TO 10% CHANGE •ee4b='eo 44 d34e4e 4 4e.o CLASS A3 IH.E.S.1 CONC. g4de 6" A.GCR. BASE TYPE I SIZE 21B • �• 12% MAX. SLOPE I 5'-0" ® POINT OF GRADE CHANGE p• FOR CURB AND GUTTER ONLY 111 • 1;, • �. • �. FOR SIDEWALK CURB AND GUTTER x x 12 X MAXIMUM INCREASE IN SLOPE AT MINIMUM 10' INTERVALS 10•o • o • o BUILT CONCURRENTLY o.o•o•o• qo. o o • Kill SECTION C-C x x x 3 % MAXIMUM DECREASE IN SLOPE FOR FIRST 10' INTERVAL AND B X MAXIMUM DECREASE FOR SUCCEEDING MINIMUM 10' INTERVALS SECTION D-D SPECIFICATION ,V DOT REFERENCE STANDARD ENTRANCE GUTTER ROAD AND BRIDGE STANDARDS 502 REVISION DATE SHEET I OF 1 203.02 VIRGINIA DEPARTMENT OF TRANSPORTATION 07/15 1992 3.38 Source: Va. DSWC III - 401 Plate 3.38-2 iCOTT/R. CbLLINS_Z Lic. No. 035791 a 5/24/21 ,�fj r/ Z Z J O Q 0 a K DO V/ w u=) � J Z Q 'll♦ O 1- U) z W L ~ ICe I n D C. LU V / J J z w ILL. 0 1 06 I--1 (/) LLI i oC 0 z 0 Q F- LU O LU 01 2 11 UT JOB NO. 112066 SCALE AS NOTED SHEET NO. 6A ACSA GENERAL WATER & SEWER CONDITIONS (June 27, 2019) 1. WORK SHALL BE SUBJECT TO INSPECTION BY ALBEMARLE COUNTY SERVICE AUTHORITY (ACSA) INSPECTORS. THE CONTRACTOR WILL BE RESPONSIBLE FOR NOTIFYING THE PROPER ACSA OFFICIALS AT THE START OF THE WORK. 2. THE ALBEMARLE COUNTY SERVICE AUTHORITY SHALL HAVE ACCESS TO USE THE AIRSPACE ABOVE THE LOCATIONS OF CONSTRUCTION FOR THE FLIGHT OF UNMANNED AERIAL VEHICLES FOR THE PURPOSE OF IMAGERY COLLECTION. 3. THE LOCATION OF EXISTING UTILITIES ACROSS THE LINE OF THE PROPOSED WORK ARE NOT NECESSARILY SHOWN ON THE PLANS AND WHERE SHOWN ARE ONLY APPROXIMATELY CORRECT. THE CONTRACTOR SHALL, ON HIS OWN INITIATIVE, LOCATE ALL UNDERGROUND LINES AND STRUCTURES, AS NECESSARY. 4. ALL MATERIALS AND CONSTRUCTION SHALL COMPLY WITH THE CURRENT EDITION OF THE GENERAL WATER AND SEWER CONSTRUCTION SPECIFICATIONS, AS ADOPTED BY THE ACSA. 5. DATUM FOR ALL ELEVATIONS SHOWN IN NATIONAL GEODETIC SURVEY. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING MISS UTILITY (1-800-552-7001). 7. ALL WATER AND SEWER PIPES SHALL HAVE A MINIMUM OF THREE AND A HALF (3.5) FEET OF COVER MEASURED FROM THE TOP OF PIPE, OVER THE CENTERLINE OF PIPE. THIS INCLUDES ALL FIRE HYDRANT LINES, SERVICE LATERALS AND WATER LINES, ETC. 8. ALL WATER AND SEWER APPURTENANCES ARE TO BE LOCATED OUTSIDE OF ROADSIDE DITCHES. 9. VALVES ON DEADEND LINES SHALL BE RODDED TO PROVIDE ADEQUATE RESTRAINT FOR THE VALVE DURING A FUTURE EXTENSION OF THE LINE. io. TREES ARE NOT PERMITTED IN THE ACSA EASEMENT. ii. THE CONTRACTOR SHALL BE RESPONSIBLE TO COMPLY WITH THE NO- LEAD REGULATION REGARDING BRASS FITTINGS EFFECTIVE JANUARY 4, 2014 (SENATE BILL 3874 WHICH AMENDS THE SAFE DRINKING WATER ACT). 12. THE SEWER LATERAL BEYOND THE CONNECTION AT THE SEWER MAIN SHALL BE PRIVATE. THE SEWER LATERAL STUB -OUT SHALL UNDERGO THE ACSA LOW-PRESSURE AIR TEST TO SATISFY COUNTY TESTING REQUIREMENTS. VISUAL INSPECTION OF THE SEWER LATERAL STUB -OUT SHALL BE WITNESSED BY THE COUNTY BUILDING INSPECTIONS DEPARTMENT. THIS INSPECTION SHALL OCCUR UNDER AN "OTHER PLUMBING" PERMIT WHICH MUST BE OBTAINED BY THE CONTRACTOR. 13. THE SEWER LATERAL BEYOND THE CONNECTION AT A MANHOLE SHALL BE PRIVATE. VISUAL INSPECTION AND PRESSURE TESTING OF THE SEWER LATERAL SHALL BE WITNESSED BY THE COUNTY BUILDING INSPECTIONS DEPARTMENT. THIS INSPECTION SHALL OCCUR UNDER AN "OTHER PLUMBING" PERMIT WHICH MUST BE OBTAINED BY THE CONTRACTOR. 14. THE FIRE SPRINKLER MAIN DOWNSTREAM OF THE GATE VALVE IS PRIVATE. VISUAL INSPECTION AND TESTING OF THE FIRE SPRINKLER MAIN DOWNSTREAM OF THE GATE VALVE SHALL BE WITNESSED BY THE COUNTY BUILDING INSPECTIONS DEPARTMENT. THIS INSPECTION SHALL OCCUR UNDER AN "OTHER PLUMBING" PERMIT WHICH MUST BE OBTAINED BY THE CONTRACTOR. 15. ALL FLUSHING OF FIRE SPRINKLER MAINS SHALL NOT OCCUR UNTIL APPROVAL IS GIVEN BY THE ACSA. GOOD FOUNDATION MATERIAL ROCKY FOUNDATION MATERIAL D P�4"vL B, INITIAL BACKFILL 824 IN 6' MIN MIN. IN. MIN. �� 6" BEDDING #68 STONE * STABLE SOIL ROCK ' SCRAPE THE BOTTOM OF THE TRENCH. REMOVE ALL STONES TO INSURE THE PIPE DOESN'T REST ON ROCK AND THEN COMPACT THE SOIL OR PROVIDE A 4" BEDDING OF #68 STONE. FOUNDATION IN POOR SOIL UNDER -CUT CONDITION a INITIAL BACKFILL a MI UNSTABLE B^ 8"'e' 6^ SOIL\- MIN MIN. _ MIN MIN. #68 STONE �';• ' - �RANULAR FILL AS _ �APPROVED BY ACSA S ABL SOIL 0 ROCc( n STABLE SOIL OR ROC NOTE 1. NO ROCKS SHALL BE ALLOWED WITHIN 24" OF THE WATER LINES. 2. NO ROCKS LARGER THAN 6" IN ANY DIMENSION SHALL BE ALLOWED ABOVE THE INITIAL BACKFILL. 3.THE INITIAL BACKFILL SHALL BE PLACED AND COMPACTED IN 6" LIFTS. 4. NO ORGANIC OR FROZEN MATERIAL OR DEBRIS SHALL BE ALLOWED IN THE TRENCH. 5. BELL HOLES SHALL BE DUG OUT IN ALL CASES. DUCTILE IRON WATER PIPE INSTALLATION & BEDDING NTS FIG. INI TD-2 JUNCTION BOXES, TRANSFORMER PADS, PEDESTALS, ETC. SHALL NOT BE LOCATED WITHIN THE RIGHT OF WAY, VARIES 1 5' r110 I 5' III ._. I _15' 1 I r I WATER SEWER 3 A EA EA LOCATION OF OTHER UTILITIES /(GAS, ELECTRIC, TELEPHONE, CABLE, ETC,) EASEMENT WIDTHS, WATER OR SEWER ONLY - 20' MINIMUM WATER M SEWER 30' MINIMUM x SEE PART 3, PARAGRAPH ➢1 SEPARATION OF WATER B. SEWER SYSTEMS. UTILITIES CROSSING A WATER OR SEWER EASEMENT SHOULD BE AT 90• TO THE RIGHT OF WAY. UTILITY LOCATIONS & EASEMENT WIDTHS a NITS FIG. W-1 TD-1 PLACE 5' GALVANIZED " WITNESS " POST WITH CAPPED ENDS PAINTED BLUE IN REMOTE AREAS AS DIRECTED. MARKER LOCATION MAY BE SUBJECT TO IT DEPARTMENT APPROVAL. FINISHED GRADE VALVE BOX W/ LID T T M.J. GATE VALVE LA WATER V2'. 2500 P-SJCONCRETE4G AREA. THRUST BLOCK 4 A° a • NOTE IN REMOTE AREAS, VALVE BOXES SHALL EXTEND SIX (6) INCHES ABOVE GRADE. TYPICAL GATE VALVE NTS FIG. W-5 D-9 151/2" E.J.I.W. 1574 CAST IRON CLEANOUT FRAME AND LID SO 1/4" INSTALLED FLUSH WITH FINISHED SURFACE CONCRETE COLLAR POURED 71R„ SEE PAVEMENT AROUND CLEANOUT COVER EXISTING GRADE REPLACEMENT (3500 PSI) REQUIREMENTS if C FEMALE CLEANOUTADAPTER X - LIAUE j IM TH INVERTED NUT SCREW CAP ORAT ::: SLOTTED SCREW CAP KOR-N-SEAL No. S406-10 AWS" " WITH 10 1/4" BAND PVC PIPE SEE BACKFILL AND BEDDING 45° BEND REQUIREMENTS PVC PIPE SEWER UATERAL FUTURE, --- SANITARY LATERAL WYE 1 1 1�------------ i BOTTOM OF TRENCH SECTION 'A -A' SEWER _ A CUSTOMER I EASEMENT OR RIGHT-OF-WAY FUTURE SANITARY LATERAL (WHEN INLINE LAYOUT REQ'D)1 1 CAST CLEANOIfT -...-.._..:_ IISIl FRAME AND LID FRAME - - - - - - �tI^- N L{L _ �.E SEWER LATERAL A A CONCRETE 45° BEND COLLAR - PLAN VIEW - - _ STANDARD SANITARY CLEANOUT IN PAVED AREAS 1A BEND FM0III &�:.- SECTION 2-2 PIPE DEGREE BEND DIMENSIONS VOL. TEE AND PLUGS VOL. SIZE OF (FEET) CU.YD. (FEET) CU.YO BEND L H T L H T 90 2.50 2.50 3.01 0.24 4" & 6" 45 22 1/2 2.00 1.50 2.25 2.00 2.60 2.52 0.15 0.10 2 00 225 2.50 0.15 11 1/4 1.50 2.00 2.50 0.10 90 3.66 3.16 3.21 0.48 8' 45 2.66 2.68 7 2. 7 0.26 22 1/2 1.66 2.16 2.89 0.13 3.18 2.91 2.66 032 11 1/4 1.66 2.16 2.67 0.13 -& 90 4.83 3.83 3.42 0.83 FIO 12 45 3.33 3.58 2.95 0.43 383 4.00 2.83 0.52 22 1/2 2.33 2.58 2.86 0.24 11 1/4 1 1.83 1 2.33 2.84 10.18 I. THRUST BLOCKS ARE REQUIRED WHENEVER THE PIPELINE - CHANGES DIRECTION, CHANGES SIZE, DEAD ENDS AND AT VALVES. 2, USE 2500 P.S.I. CONCRETE. 3. NO CONCRETE SHALL BE POURED ON ANY PART OF THE JONT. C THE CONSULTING ENGINEER SHALL BE RESPONSIBLE TO THE VERIFY THE TYPE & SIZE OF ALL THRUST BLOCKS. CONCRETE THRUST BLOCKS NTS He W-3 TD-3 '• ^MIPRES9g1 " 3/4• MNE PIPE COUPLING PMUPD E0.1PL t• TiPE •K \ �� / sOPT cDPPm .� p / FOR USE M ATTAIHEG VNIOUDUAL FAMILY REDAND INADAl ON voESSERY m DuaL REslDwnu AND IraBwnm sxncEs. I'n'd SEE OI NO E NO SYFAnD mnIXS 1. 77 DUAL SERVICE 2 1- COYPIEMON r 31C UAL£ PIPE COUPLING DR es 0 Vx_ r TmE x R"WP d uON oERSWLE FAMILY DEAN Wv u EDE WERE AN YEIEA SOE PROV00 SINGLE SERVICE NOTE 1) SADDLES "LI BE U¢D ON PVC PPE TYPICAL SERVICE LATERAL INSTALLATION (5/8" & 1" METERS) NTS FIG. W-6A TD-10 - z I A T 12" f J 3000 PSI CONC. BASE BENCH SLOPED TO FLOW CHANNEL 1/4" 1' MIN BRANCH FLEXIBLE CONNECTION J1+ NOTE: WITH STAINLESS STEEL ALL CONNECTIONS TO BAND EXISTING MANHOLES SHALL BE CORED AND A FLEXIBLE w CONNECTION BOOT " J 70 INSTALLED TYPICAL MANHOLE PLAN SHOWING BRANCH TIE - IN NTS FIG. S-1-B TD-27 Top View 6" MINIMUM a ° 4' MI °( A a 4" MINIMUM NOTE: RESTRAINED JOINT FITTINGS. Side View 42" Minimum --- ZA CerflRcaflon of 95Z �I 1 11 compaction required Q 4 Galvanized Steel Beam W12 x 14 (min, size) 3' min. penetration into undisturbed 45' soil , or as approved by the < / ACSA. TYPICAL THRUST BLOCK IN FILL AREA NTS FIG, W-38 TD-5 NOTE, MIN. 60- DIAMETER MANHOLE REGUIRED. I= •sEP C(FSP.t CROP MANIOLE PVC CROSS \ol z. USE APPROVED FLEXIBLE RUBBER n 110I e c� 4' L TOPG'Ep 'Ill TOP couPL["c o e7• DROP PIPE PIPE STRAPS (STAINLESS STEEL) 0 SPACED EVERY r VERTICALLY }ljL 90' RESTRAINED BEND seAER W ELL'EM1T 'I "E WAIN • 4A."A •.A •... SERI PIPE PLAN PROFILE MIN. 6' BEDDING WITH NO. 69 STONE L HEIGHT OF THE VERTICAL DROP PIPE WILL BE DETERMINED BY THE ACSA BUT SHALL NOT BE LESS THAN TWO (2) FEET. 2 VERTICAL DROP PIPE SHALL BE SDR 26 P.V.C, SIZED THE SAME AS THE INCOMING PIPE AND CONNECTE DTC THE DROP FFMNG WITH STANDARD GASKET JOINT. 3-VERTICAL DROPPIPESHALLBE STRAPPEDTOTME MANHOLE AT PIPE JOINTS. STRAPSSHALL BE MADEOF STAINLESS STEEL 4. SHAPE INVERT AS NEEDED TO PROVIDE SMOOTH TRANSITION FROM DROP CONNECLION DISCHARGE POINT TO SPRING LINE OF MANHOLE INVERT. 5. DROP CONNECTION DISCHARGE FI TING SHALL 6E ORIENTED AT 45 DEGREES, INTO TH E FLOW. 6. VERTICAL DROP PIPE SHALL BE INSTALLED AT 90 DEGREES FROM THE ACCESS STEPS. 7. MIN IM UM 72' DIAMETER MANHOLE REQUIRED FOR A SINGLE 10" OR 12" DIAMETER DROP CONNECTION, OR TWO 8" DIAMETER DROP CONNECnONS. STANDARD INTERNAL DROP CONNECTION N.T:S. FIG. S-1-C2 TD-30 >E E \E " n Q \E _E -� HE oUP u. o , 0 aEax S E o `E LE LE � E o E 0 m�mz n�� o �a N o E 2 <o \z o m E �o E _ =E E a n a E �E E N E O < 00 nO1. _ :@:� �E �E <_ of w ^NE r 12 a 0 TYPICAL MANHOLE FRAME &COVER N.T.S FIG STO TD-31 FINISHED GRADE TI�f�TT-IT -TIT-ITI-TT(-TIr-ITT-T - TRENCH e 4' REDUCER e RE-2500 P.S.I. CONCRETE THRUST BLOCK - - - - - - - - - - - - - - - - A B UNDISTURBED SOIL 16' MN } PROFILE VIEW UNDISTURBED SOIL - EDGE " T - - OF TRENCH- 4 24 MN ------ - - ---- REDUCER 6' MN ___4 2500 P.S,I. CONCRETE THRUST BLOCK • SIR MN -- --- -e. `a -------------- UNDISTURBED SOIL - EDGE OF TRENCH •'° 24" MN. NOTES: PLAN VIEW NOT TO SCALE NO CONCRETE SHALL BE POURED ON ANY PART OF THE MECHANICAL JOINT. USE PLASTIC SHEETING AS PROTECTION FOR BOLTS. 3' MINIMUM HORIZONTAL PENETRATION INTO UNDISTURBED SOIL ON BOTH SIDES OF TRENCH, OR AS APPROVED BY THE ACSA. 3' MINIMUM VERTICAL PENETRATION INTO UNDISTURBED SOIL, OR AS APPROVED BY THE ACSA. CERTIFICATION OF 95% COMPACTION REQUIRED IN TRENCH, THE CONSULTING ENGINEER SHALL BE RESPONSIBLE TO VERIFY THE TYPE AND SIZE OF ALL THRUST BLOCKS. TYPICAL REDUCER THRUST BLOCK NTS FIG. W-3D TD-7 ,- -,.--- 9 COVER LIFT NOTCH 12 3/8" WATER CAST IRON LID NOTES: (1) A 1-3/4" DIAMETER HOLE IS REQUIRED IN THE UD FOR TOUCH READ METERS. TYPICAL METER BOXES (5/8"-1" METERS) NTS FIG. W-7 TD-13 SEWER SERVICE LATERAL CONNECTION NOTES: 1. WHERE A SEWER SERVICE LATERAL CONNECTS A MANHOLE AND NO INVERT ELEVATION FOR THE SERVICE LATERAL IS INDICATED , THE TOP (CROWN) ELEVATION OF THE SERVICE LATERAL PIPE SHALL BE AT LEAST 02' HIGHER THAN THE TOP (CROWN) ELEVATION OF THE THE LOWEST PIPE CONNECTED TO THE MANHOLE. 2. SEWER LATERALS TAPPED INTO AN EXISTING SEWER MAIN SHALL BE CONNECTED USING A PIPE SADDLE. 3. MINIMUM GRADE FOR SEWER SERVICE CONNECTION SHALL BE 2% �I (1/4" PER FOOT ) 4. ALL SEWER LATERALS SHALL HAVE A MINIMUM COVER 2' MIN DIAMETER OF 4". 5. ALL SEWER LATERALS SHALL HAVE A MINIMUM COVER OF 3 FEET. SALT TREATED FINISHED GROUND MARKER PLUG END OF MAIN LINE T SECTION SERVICE LATERAL IN LINE WYE-TEE PLAN VARIES k' SEWER SERVICE LATERAL CONNECTION N.T.S. FIG. S-2 TD-33 NOTE: HYDRANT MUST BE EQUIPPED WITH CHARLOTTES- VILLE THREADS WHICH IS THE LOCAL STANDARD. LENGTH OF BRANCH VARIES (270') MIN 2' TO 10' CU. FT. 18'-22'vALVE BOX g6H STONE 42'MIN 8' GATE ,., VALVE TEE 2500 111 CONCRETE BASE AND THRUST BLOCKAGAINST UNDISTURBED \ r UNDISTURBED STABLE \V' SOIL. STEEL PILE WHEN THE SOIL IS DISTURBED OR EN RESTRAINED JOINT FlTIINGS A HYDRANT IS LOCATED IN A HILL, IN ADDITION TO POURING CONCRETE, A STEEL PILE SHALL BE USED AS ADDITIONAL SUPPORT, NOTE 1. SURROUND WEEP HOLES WITH GRAVEL AND KEEP FREE OF CONCRETE. 2. MAINTAIN A 3 1/2' MIN. COVER FROM THE MAIN TO THE FIRE HYDRANT ( INCLUDING DITCHES ) 3. FINISHEDGRADE SHALL SLOPE AWAY FROM THE FlRE HYDRANT AND VALVELVEBOX 4. THE GATE VALVE IS ALLOWED IN SHOULDER OR BEHIND THE DITCH. IT IS NOT ALLOWED IN THE DITCH. 5. FIRE HYDRANTS SHABE INSTALLED AT LOCATIONS WHERE WEEP HOLES ARE ABOVE THE PREVAILING GROUNDWATER SHAUT E IF R LUGGED O N BE IN WET AREAS. THE WEEP HOLES SHALL BE PLUGGED AND THE HYDRANT SHALL BE PUMPED DRY. TYPICAL FIRE HYDRANT ASSEMBLY DETAIL N.T.S. FIG. IN TD-B GRADE AIR RELEASE VALVE V BRASS OR BRONZE PIPE BRONZE GATE BRICK SUPPORTS OR SOLID CEMENT BLOCKS TYPE 'K" SOFT COPPER STOP STONE NOTES- 1 ) A PRECAST MANHOLE CONE AND COVER WITH WATER CAST ON LID FOR TRAFFIC AREAS, OR A METER BOX ASSEMBLY IN NON -TRAFFIC AREAS, OR APPROVED EQUAL, SHALL BE USED. 2) FOR WATERLINES SMALLER THAN 12" USE A 1" A.R.V. AND FITTINGS. FOR WATER LINES 12" AND LARGER USE 2" A.R.V. AND FITTINGS. 3) IN SITUATIONS WHERE THE A.R.V. ASSEMBLY CANNOT BE OFFSET FROM THE MAIN AN ADEQUATE FOUNDATION SHALL BE INSTALLED SO THE WATER LINE DOES NOT SUPPORT THE MANHOLE CONE. AIR RELEASE VALVE (ARV) NITS FIG. W-9 D-20 8"MIN EMBEDMENT SPRING E O OF PIPE NO. 68 STONE _ REMAINING BACKFILL SHALL NOT CONTAIN ROCK MATERIAL LARGER THAN 5" IN ANY DIMENSION -INTIAL BACKFILL" (6" LIFTS) • THOROUGHLY COMPACTED BY HAND OR APPROVED MECHANICAL TAMPER -HAUNCHING -BEDDING 6" max 4" min -FOUNDATION (SHALL BE REQUIRED WHEN SOIL CONDITIONS ARE UNSTABLE NOTE 1. OPEN CUTS IN PAVED AREAS WITHIN EXISTING VOOT RIGHT-OF-WAY SHALL BE BACKFILLED ENTIRELY WITH NO. 21A STONE. 2. FOR DUCTILE IRON PIPE THE BOTTOM OF THE TRENCH SHALL BE SCRAPED AND COMPACTED, AND ALL STONES REMOVED OR A 4" BEDDING OF NO. 68 STONE SHALL BE PROVIDED 3. WHERE ROCK IS ENCOUNTERED PIPE SHALL BE INSTALLED ON A MINIMUM 6" BEDDING OF NO. 68 STONE TYPICAL SEWER PIPE INSTALLATION IN TRENCH NTS FIG. S-3 TD-34 ;COTT/R. CbLLINSZ Lic. No. 035791 a 5/24/21 A Z Z J O Q 0 a � m ED Gn Z J Z Q 'll♦ 0 F > Z W � ~ LD v, r y� \ A p 01 co co V 1 r N C) N z w N Q J > I= W W J_ LU J J o z 1 I --I W =1 1 `06 LlI U I -I v ) Y 1--I W LU UlI Q w z ZUj O J v~l LU CD ® CDN U � 0 UH- JIJ � U) a U) JOB NO. 112066 SCALE AS NOTED SHEET NO. 7 HIGH PT STA: 10+01.56 HIGH PT ELEV: 687.85OW PT STA: 11+59.82 PVI STA:10+24.06 LOW PT ELEV: 682.65 PVI ELEV:687.50 PVI STA:11+09.82 K:13.32 PVI ELEV:683.30 LVC:45.00 K:27.86 LVC: 100.00 co U-) co 0 ��N to Nan _Ln� C r 0 + Co � cD } cCF� L 6) N 0 0 Co LO Co W �> n> _ W um Wn> V)> 690 II II 1 1 1 II o -1.52 0 PROPOSED Fz FIRE HYDRANT + ASSEMBLY w/ 6"x6" TEE & 685-4'90%3.5' (2) 6" G.V. 680 6"X6" TEE (2) 6" G.V. 675 0 H PT STA: 11+71.20 PVI S A:12+11.20 PVI LEV:681.98 A:21.67 L C: 80.00 I � POSED 4" SANITAR ER LATERAL (TYP.) PROPOSED 8" SANITARY 670 SEWER CROSSING PROPOSED 12"x6" CROSS, (1) 12" G.V. & (2) 6" G.V. 665 PROPOSI ATERLINE 660 9+50 PROPOSED 45° VERTICAL BEND 1.6fl' PROPOSED 45' VERTICAL BEND INTERSECTION OF HATHAWAY STREET (STA 10+96.75) ANI DESOTOI DRIVE (STA EXISTING GRADE (TYP.) 685 PROPOSED GRADE (TYP.) PROPOSE VDOT 6 8 0 STD. CD-i -5.00% FILL TO BE PLACED AT 95%COM�PACTI N(TYP.) 4" DUCTILE IRON SANITARY SEWER LATERALS PROPOSED (1) 6" G.V. TYPE A BLOW -OFF ASSEMBLY f+l W M „mj rl M 0 d 0 O O� L!1 N ^ .t a) 6 00 't S N N 00 00 4 00 M 00 6 V1 rl � w kD ID W ID l0 W ID � w kD l0 10+00 10+50 11+00 11+50 12+00 12+50 13+00 �DESOTO DRIVE PROFILE 670 665 660 13+50 14+00 PROPOSED TYPE A E F 700 O O EXISTING GRADE (TYP.)� MA/ PT cTo in��7 n7 700 LOW PT ELEV: 687. 5 PVI S A:10+63.48 PVIELEV: 687.36 26.88 695 L a115.o0 695 o Co PROPOSED GRADE (TYF O N 0 690 "> ()w 3% 690 > 3.5' MIN. PROPOSED 8" PROPOSED VDOT ROOF DRAI STD. CD-2 685 CROSSING 1.0' (1) 6" G.V. 3.4' PROPOSED (1) 6' LOW -OFF TYPE A BLOW-0 ASSEMBLY SSEMBLY 0 0 0 0 0 PROPOSED 6"x6" TEE, 675 (2) 6" G.V. PROPOSED 4" SANIT PROPOSED 6" CL. 52 DI WATERLINEJ SEWER LATERAL (TY 670 670 1O i. m ? m °. 00 0000 0000 ? O O) tD n N 00 0)00 tD W N 0) tD D1 00 ID O m w PROPOSED GF G.V. & FF PR( (1) 1: ARY BL' p) AS. 9+50 10+00 10+50 11+00 11+50 12+00 12+50 �ANOKO COURT PROFILE 720 720 715 715 710 LOW P STA: 11+16.94 710 LOW PT ELEV: 68213 PVI TA:10+66.9 PVI ELEV:682.92 K: 30.73 705 L c:loo.o0 705 co L6 o Co +Co +(o 0 700 w 700 m W INTERSECTION OF HATHAWAY STREET (STA 10+96.75) AND DESOTO DRIVE 695 (STA 695 EXISTING GRADE (TYP.) DE(TYP 690 )POSED "G.V.& 4 a 685 TYPE A OW -OFF iEMBLY 3.5' -1 59% 680 MIN. 680 PROPOSED W 1.8 ROOF DRAIN CROSSING TIE-IN TO EXISTIN( 4.9' 1. 5' 675 1i.1 675 PROPOSED FIRE HYDRANT ASSEMBLY w/ 12"x6" TEE "T01 (1) 12" G.V. & (1) 6" G.V. 670 9 TO 8 670 EXISTING 12" I PROPOSED 17"x6" CROSS, REMOVE (1) 22" G.V. & (z) 6" G.V. & TIE-IN TO EXISTING 1: WATERLINE MH-3 TO MH-2 665 665 PROPOSED 12" CL. 52 DI WATERLINE 660 660 N e^i Ch N t b w CO W N 0 M lD 00 lD 00 lD 00 lD lD 00 lD 00 l0 I � LD 9+50 10+00 10+50 11+00 11+50 12+00 12+50 HATHAWAY STREET PROFILE VERTICAL GRAPHIC SCALE 5 n 2.5 5 10 ( IN FEET ) 1 inch = 5 1t. HORIZONTAL GRAPHIC SCALE 25 50 100 ( IN FEET ) 1 inch = 50 it. 20 GRADE 3.O.V. >" DI 13+00 13+50 NOTE: SANITARY LATERALS CROSSING OVER WATERLINE SHALL HAVE ADEQUATE STRUCTURE SUPPORT FOR THE SEWERS TO PREVENT EXCESSIVE DEFLECTION. IN ADDITION, THE LENGTH OF THE WATERLINE SHALL BE CENTERED AT THE POINT OF THE CROSSING SO THAT JOINTS SHALL BE EQUIDISTANT AND AS FAR AS POSSIBLE FROM THE SEWER. THE LENGTH OF THE SEWER PIPE SHALL ALSO BE CENTERED AT THE POINT OF THE CROSSING, SO THAT THE JOINTS SHALL BE EQUIDISTANT AND AS FAR AS POSSIBLE FROM THE WATERLINE. NOTE: ALL ROADWAY EMBANKMENT MATERIAL SHALL CONSIST OF SOIL AND BE PLACED IN SUCCESSIVE UNIFORM LAYERS NOT MORE THAN 8 INCHES IN THICKNESS BEFORE COMPACTION OVER THE ENTIRE ROADBED AREA IN ACCORDANCE WITH VDOT 2007 ROAD AND BRIDGE SPECIFICATION 303.04 NOTE: CLASS I BACKFILL MATERIAL SHALL BE CRUSHER RUN AGGREGATE SIZE NO. 25 OR 26, AGGREGATE BASE MATERIAL SIZE 21A OR 21B, FLOWABLE FILL, OR CRUSHED GLASS CONFORMING TO THE SIZE REQUIREMENTS FOR CRUSHER RUN AGGREGATE SIZE 25 AND 26, PER VDOT ROAD AND BRIDGE SPECIFICATIONS, SECTION 302.03G. NOTES: 1. ALL FILL TO BE PLACED AT 95%COMPACTION. 2. MINIMUM 3.5' OF COVER MUST BE MAINTAINED OVER W/L. 3. MINIMUM OF 1' OF VERTICAL SEPARATION FROM STORM SEWER & W/L AND 1.5' OF SEPARATION BETWEEN SANITARY SEWER MUST BE PROVIDED. Lie. No. 035791,'n 8/26/214i r z w 0 U z Z 0 o J a 0 o U Lu O u U V w m D _ F U, 0 !n J Z_ u o 0 � Ln w w 0 1n z .. 0 w a �W/ Lu v � o Ln 00 Ln 00 r'7 N O Cn N w N > 7 w J J U) ul 0 Q W Lu in z W Lu 0 O L z QW J Lu J z z J u- W a � z a a a� z O' 0 a o w x a � JOB NO. 112066 SCALE 111 = 501 SHEET NO. 8 HIGH PT STA: 10+16.98 HIGH PT ELEV: 672.81 �TH 0 PVI STA:10+34.40 PVI ELEV:672.99 K: 2.59 LVC: 40.00 SCOTT R. LINS'Z o m o o U Lie. No. 035791,E �tr- �t- 4 � 4 o 110 8/26/21 �4 + + SIONAL E�O1 Li w 675 Cn> > 675 z w z 0 U 0 c 00 U z v 3 690 690 z ZZ z O Q O U O a kW V m u D L7 w U1 Z 3 0 J 1�1 Z w rn z o o Lu W a s N `O m V o w 0 0 2 0 U O 'y a o Ln 00 _ 0 r U rn 1 _ 0 0 M 0 (y 3 � � m N 0 a T 0 N O -� O N Z N N /Q W U,J 0+00 0+50 1+00 1+50 12+00 2+507 J 0 PRIVATE ROAD PROFILE w u) w J J ul Q o z 3 o= n U Q 0 _ 0 a U W �Q� F1 � Y o0 YW T E Co m CD Co j CD '^ Vl CD ul Z z w LU w Lj Z W o z w > z Z U) QU J � U NOTE: ALL ROADWAY EMBANKMENT MATERIAL W SHALL CONSIST OF SOIL AND BE PLACED IN o SUCCESSIVE UNIFORM LAYERS NOT MORE THAN 8mmi Q INCHES IN THICKNESS BEFORE COMPACTION OVER Ur m THE ENTIRE ROADBED AREA IN ACCORDANCE WITH O x VERTICAL GRAPHIC SCALE VDOT zoo? ROAD AND BRIDGE SPECIFICATION 303.04 O 0 N r 5 0 2.5 5 10 20 N NOTE: CLASS I BACKFILL MATERIAL SHALL BE CRUSHER RUN AGGREGATE SIZE NO. 25 OR 26, AGGREGATE BASE MATERIAL y SIZE 23.A OR 2iB, FLOWABLE FILL, OR CRUSHED GLASS ( IN FEET) CONFORMING TO THE SIZE REQUIREMENTS FOR CRUSHER inch = 5 ft. RUN AGGREGATE SIZE 25 AND 26, PER VDOT ROAD AND U tu- BRIDGE SPECIFICATIONS, SECTION 302.03G. 10 o Lu HORIZONTAL GRAPHIC SCALE a L s U 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 17+99.50 50 0 25 50 100 200 NOTES: JOB NO. ° s. ALL FILL TO BE PLACED AT 95%COMPACTION. 112066 P R V ATE DRIVE PROFILE 2. MINIMUM 3.5' OF COVER MUST BE MAINTAINED OVER W/L. SCALE 3. MINIMUM OF i' OF VERTICAL SEPARATION FROM STORM „ , m ( IN FEET) SEWER & W/L AND i.5' OF SEPARATION BETWEEN W/L & 1 = .50 `o 1 inch = 50 Ft. SANITARY SEWER MUST BE PROVIDED. n SHEET NO. � 9 -2.00% 07 LOW PT TA: 12+55. 0 LOW PT ELEV: 643.8 PVI STA: 12+09.88 p PVI E EV:647.63 670 K:15.00 670 cO HIGH T STA: 10+ 2.02 HIGH PT ELEV: 6 5.36 685 PVI STA:10+72. 6 685 P I ELEV:676.78 K: 17.30 LVC:140.00 680 � + 680 w U m � w 675 675 0 'FILL TO BE PLACED AT POSED GRADE (TYP.) 670 95%COMPACTION(TYP.) � 670 665 EXISTINGGRADE(TYP.) 665 660 660 655 655 650 650 O � .} N O N N� � l0 l0 l0 l0 lD � lO 710 710 710 710 710 710 SCOTT R. LINS'Z U Lie. No. 035791 !n 5/24/21 c�4 o��SSIONAL E�G1 w w z z w z J 0 U 0 c IL 0 06 c 3 N r— N n x m Z Z J t o ¢ O k m o u w IL 3) o/ w D 3 Z J m z I..l o > z N > c LLJ w o U 0 U 0 a 0 m a 0 U J 0 U 0 a N w � N � Ln Ln Lu C 3 U V/ N A� > 1 _ O 0 ('M 0 (y 3 OD rl ® m It 0 N 0 rl 0 n n o -0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 -0+50 0+00 0+50 1+00 -0+50 0+00 0+50 1+00 1+50 N o �MH-4 TO EX MH PROFILE�MH-5 TO MH-3 PROFILE�MH-6 TO MH-2 PROFILE W z N Q J ° > 0- ul L L u uj J J ` J I-� O o U - J ° ul Lu � Q O z 3 w= LU Q 0 W O _ w o Y U Q - ul r� zC QZ v) z w Lu w w Z z � w > Z � QU U JL J w Q O L VERTICAL GRAPHIC SCALE 0 5 ° 2.5 5 ,° 20 NOTES: o 1. ALL FILL TO BE PLACED AT 95%COMPACTION. ( IN FEET) z. MINIMUM 3.5' OF COVER MUST BE MAINTAINED OVER W/L. 6 1 inch = 5 1t. 3. MINIMUM OF z' OF VERTICAL SEPARATION FROM STORM U °a SEWER & W/L AND i.5' OF SEPARATION BETWEEN W/L & I 'r' O w m HORIZONTAL GRAPHIC SCALE SANITARY SEWER MUST BE PROVIDED. a In o U JOB NO. 0 50 0 5 50 00 200 112066 0 NOTE: CLASS I BACKFILL MATERIAL SHALL BE CRUSHER RUN AGGREGATE o SIZE NO. 25 OR 26, AGGREGATE BASE MATERIAL SIZE ziA OR 21B, FLOWABLE SCALE 0 ( IN FEET) FILL, OR CRUSHED GLASS CONFORMING TO THE SIZE REQUIREMENTS FOR 1�� = 50, 0 1 inch = 50 it. CRUSHER RUN AGGREGATE SIZE 25 AND 26, PER VDOT ROAD AND BRIDGE n SPECIFICATIONS, SECTION 302.03G. SHEET 10 r 705 705 M I N 2 2 =I =� O 7OO XISTINGGRADE(TYP.) Oo� ii 7OO I r rn� � O °00 Oc0 I p~ ¢ IJ��OF �co0 695 =_ ��zzo Paz 695 0 NFz zz M ���fffOJJJ 690 I � 690 I °i.cOO• ROPOSEDGRADE(TYP.) Y � � � � Z Z z "� o o oa;� � a» N�z z � 685 ¢�z o �° 685 NHz� 11 TO 10 PROPOSED iz" WATERLINE CROSSING 680 680 G 5o.42�F 1.5 675 a^S° �.•� � 1.2 11°.5 675 13 TO 9 670 a"5 z6P2. 4 F C % 670 y2z.,.9 665 665 660 660 01 m W 0 .t � 1p � 01 � 01 ^ N � Ol � Ol °D ,y O °� rl N e0 � ,y .i °D � � 3 � � � M W � 0° lD l�0 l0 t0 705 705 EXISTING GRADE (TYP.) LOCI = M I 700 0 0� 0 700 M M MO O O� N)°�I� I� 00 695 ��zzo =�� 695 � lal»> NFzzz �co0 � lal> 690 PROPOSED GRADE (TYP.) 690 PROPOSED 8" ROOF 685 CROSSING DRAT 685 .9' 2.5' 6Rn PROPOSED6" P c 680 g" SO?, WATERLINE CROSSING zl% � 97.74 675 675 670 670 665 665 660 660 N ^ Ol � 705 705 700 700 M I I Y a 695 =_� �= 695 �O S O O O �� O XIyTING GRADE (TYP.) � ISM O � 690 ¢ �� � 690 Nm��.. co (or, � °0 Z Z= F � � d»> � O ZO OF-zzz� Via» r ern`° 685 °� �� 685 680 680 PROPOSED GRADE (TYP. 675 675 8"SDR-z6 PVC TR-z6 6z.68 LF Qa o.50% 670 PVC 710 705 STR:5 VDOT STD. DI-3B (L=6') TP=677.93 INV IN: 669.57 TO 6 INV OUT: 669.47 TO 5A 695 690 3 U-) (00 o o 685 N � r-rn rnr O r ri10 0 N(D (0 to > °O(D (D .. ¢^....� (O Dz z0 u>>> 680 Naz zz EXISTING GRADE (TYP PROPOSED GRADE (TYP. STR:8 VDOT STD. DI-3B (L=6') p TP=683.53 J v INV ^: 672.18 TO 9 INV IP cO 676.08 TO C4 M 0M00 INV 01, 672.08 TO 7 0l --0 .. m 0 O~ H Lq c p M cD J p - 000 m cpN v r OOF- m M M 0 - M 0 (or" r1(o /> M(O (Or I o -O� ~O COP � rn (nZ Z0. o �-0 0 ro(D o .. 11 a> >> r rnm > o U)Fz ZZ (n I'p n CDZ z0/ 0 Mr(D � 11 d>» 0 r" .. U) i­-Z ZZ cD (o z0 Via» N azz 675 ° 0 0 PROPOSED 6" FILL (TYP.)F15"RCP W/LCROSSING 1.2' TIE-IN TO SWM FACILITY INV=667.50 15" RCP 60.44 LF ® 0.91% 665 15" RCP 6.59 LF ® 4.85% 27.97 LF ® 4.00% 655 12" m 15" RCP 39.00 LF ® 1.0( PROPOSED 4" SANITAR SEWER LATERAL (TYP.) 15" RCP 63.95 LF ® 1.00% 710 710 705 710 705 705 J ^ O M o_ ifl II o O EXISTING GRADE (TYP. ^ N 700 700 700 m o�N _� M (n o (V 00 M 0 �O o 00(o 0 0 0� > a;� I .t- o mo F CO O07 - wo 695 695 �o 695 O -oi Z� � a Z rn� 0 (D r- OO � W H - -> �(D (O.. H O M� M p �.. z0 �� DO Co..A - (oZ PROPOSED N . U) O_»> U)Z ZZ -- 690 690 GRADE (TYP.) oo � �» 690 () rzz STIR: 10 VDOT STD. DI-3B (L=6') TP=685.76 INV IN: 679.28 TO 11 INV IN: 681.18 TO 12 F R� INV OUT: 679.18 TO 9A 685 PROPOSED 6" WATERLINE CROSSING 1.0' 680 680 3.3' 15" F8 RCP 10 Ll 43.78 LF ® 1.42% MH-3 TO MH-2 0 0 15" RCP 175 62.29 LF ® 2.47% 675 PROPOSED 4" SANITARY SEWER LATERAL (TYP.) 675 �15" RCP 75.52 LF ® 1.69% 670 670 N 00 a 670 665 -0+50 0+00 0+50 (Il N 01 N 1 O (n v1 n O 't M LD n W 06 fb ~ CO N m~ (0 ID (O W 0 � W l0 ko W W w 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 �STR-11 TO SWM 1 PROFILE 4+00 655 �STR-12 TO STR-10 PROFILE PROPOSED GF EXISTING G . i (o 685 � J 685 g LO m O Q I M(O 00 � �- �-N 0 LUO O~ o HLO 680 0 ° ° O > 00 D .(D to .. O 00 0 COW mo.. Qr 0 (n (o Z O > N � (D rl ..O a> >> v'�z zz (D?O a5 675 N Fzz 670 670 !ADE (TYP.) 665 665 15" RCP 64.I33 LF ® 0.9 RADE (TYP. 660 660 FILL TO BE PLACED AT 95% COMPACTION (TYP.) 655 655 650 650 co W O � kD '0(0 0+00 0+50 A �STR-16 TO STR-5A PROFILE WA ME 710 705 705 STR:13 VDOT STD. DI-3B (L=8') TP=680.80 700 ^ INV IN: 673.47 TO 14 00 INV IN: 677.12 TO A2 INV OUT: 673.37 TO 9 Q EXISTING cD r? 0 r)00 GRADE (TYP.) 695 m 595 000 N o r'm I O) (DN H -r-� Nl 0 O 0 M(o (D.. `� M 690 m �Z Z� co V) 590 O �r- lal »> > CD N 'Lz zz r coo PROPOSED a> 685 GRADE (TYP.) N ~Z 85 680 580 PROPOSED 12" WATERLINE CROSSING PROPOSED 6" 1 TERLINE CROSSING _/ MH-3 TO MH- )11 675 4.8' 1.2 75 670 70 15" RCP 35.98 LF ®0.5 15" RCP 665 140.37 LF ® 0.50% 6 5 1� N N ,y r6 OO W N M �t (y M w w 00w ID 0)I ID w kD 0+00 0+50 1+00 1+50 2+00 �STR-14 TO STR-9 PROFILE 0% EXISTING C PROPOSED GF STR:7 VDOT STD. DI-313 (L=6') TP=680.88 700 1 INV IN: 673.34 TO 15 INV IN: 671.44 TO 8 INV OUT: 671.34 TO 6 700 J 695 m 695 I r O � N In 00 690 0 690 �(0 > 00 .. p� o (co II> 685 � az 685 RADE (TYP.) 680 1 680 AIDE (TYP.) o PROPOSED 6" WATERLINE CROSS 675 16' 675 670 15" RCP 70 28.07 LF ® 1.71 665 665 o 00 0+00 0+50 ING LSTR-15 TO STR-7 PROFILE VERTICAL GRAPHIC SCALE ( IN FEET ) I inch = 5 11. HORIZONTAL GRAPHIC SCALE 0 25 50 100 ( IN FEET ) 1 inch = 50 11. NOTE: ALL DRAINAGE STRUCTURES WITH A DEPTH OF 12' OR GREATER SHALL HAVE SAFETY SLABS IN ACCORDANCE WITH STANDARD SL-1 AS FOUND IN THE 2oo8 ROAD AND BRIDGE STANDARDS. NOTE: HDPE CAN BE USED AS AN ACCEPTABLE SUBSTITUTE FOR RCP FOR THE DRAINAGE PIPES. SEE DETAIL ON SHEET 17 FOR HDPE PIPE BEDDING INFORMATION. NOTE: ALL DRAINAGE STRUCTURES WITH A DEPTH OF 4' OR GREATER SHALL HAVE STEPS IN ACCORDANCE WITH STANDARD ST-i AS FOUND IN THE 2oo8 ROAD AND BRIDGE STANDARDS. NOTES: 1. ALL FILL TO BE PLACED AT 95%COMPACTION. 2. MINIMUM 3.5' OF COVER MUST BE MAINTAINED OVER W/L. 3. MINIMUM OF i' OF VERTICAL SEPARATION FROM STORM SEWER & W/L AND 1.5' OF SEPARATION BETWEEN W/L & SANITARY SEWER MUST BE PROVIDED. NOTE: CLASS I BACKFILL MATERIAL SHALL BE CRUSHER RUN AGGREGATE SIZE NO. 25 OR 26, AGGREGATE BASE MATERIAL SIZE 21A OR 21B, FLOWABLE FILL, OR CRUSHED GLASS CONFORMING TO THE SIZE REQUIREMENTS FOR CRUSHER RUN AGGREGATE SIZE 25 AND 26, PER VDOT ROAD AND BRIDGE SPECIFICATIONS, SECTION 302.03G. Lie. No. 035791,E 5/24/214� ZZ O U m O D w In 0 J Z .a. �..� 0 1- in z W ~ Ce In Z`7) ti M M ® m N M 1 W N CD N z N Q _ lJ ) Lu 7 Lu J J_ LL Lu O J O J 0� U- W _ W W v) 1 F� 200 5 L U-00 O ul U) a- P_ a- L'r) Lu Lu z z 10� O U) Q JLu J� Q 0 o l J 0 w a v=i JOB NO. 112066 SCALE 1" _ 501 SHEET NO. 11 W'tM �TH OFF 680 00~ 680 r IJI SCOTT R. LINS'Z cJ g U Lie. No. 035791 !n I� v3i ~060 5/24/21 �4 o O ti z 685 M m 685 685 0 ~0 685 �SSIOJVAL E�� W rn z 0 z w z J O 00) U 0 0 U P 3 N N n 56% Z rb z t o a O k V m o w p H w W 3 a� 7.91% o J z �..j o 1' i > z N W W o U 17 0 0 0 0 U 2 0 0 W N N Ln 0 —0+50 0+00 0+50 —0+50 0+00 N U C �STR-17 TO SWM-1 PROFILE STR-18 TO SWM-1 PROFILE M o (y 3 m CV a M � o CD O N z LLJ N /a^ Ln Lu W Lu c J J o LLCL eqn� O VERTICAL GRAPHIC SCALE J L9 Q 5 0 2.5 5 10 20 L O z 3 c F1 LLJ m ( IN FEET) � U Q 1 inch = 5 ft. ' LLJ HORIZONTAL GRAPHIC SCALE W Y r—i o so 0 25 50 100 200 W T E 1 inch = 50 ft. � L.L z_ II W z z NOTE: ALL DRAINAGE STRUCTURES WITH A DEPTH z W O CD z OF iz' OR GREATER SHALL HAVE SAFETY SLABS IN PROPOSEDACCORDANCE WITH STANDARD SL-i AS FOUND IN i z WITH THE 2oo8 ROAD AND BRIDGE STANDARDS. (n Q o U NOTE: HDPE CAN BE USED AS AN ACCEPTABLE o SUBSTITUTE FOR RCP FOR THE DRAINAGE PIPES. W SEE DETAIL ON SHEET 17 FOR HDPE PIPE a BEDDING INFORMATION. NOTE: ALL DRAINAGE STRUCTURES WITH A DEPTH (� OF 4' OR GREATER SHALL HAVE STEPS IN x ACCORDANCE WITH STANDARD ST-i AS FOUND IN 0 (D THE 2oo8 ROAD AND BRIDGE STANDARDS. N r NOTES: o 1. ALL FILL TO BE PLACED AT 95%COMPACTION. z. MINIMUM 3.5' OF COVER MUST BE MAINTAINED OVER W/L. E 3. MINIMUM OF i' OF VERTICAL SEPARATION FROM STORM G °a SEWER & W/L AND 1.5' OF SEPARATION BETWEEN W/L & O W SANITARY SEWER MUST BE PROVIDED. a o U JOB NO. ° 112066 NOTE: CLASS I BACKFILL MATERIAL SHALL BE CRUSHER RUN AGGREGATE -o SIZE NO. 25 OR 26, AGGREGATE BASE MATERIAL SIZE ziA OR 21B, FLOWABLE SCALE 0 —0+75 —0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 FILL, OR CRUSHED GLASS CONFORMING TO THE SIZE REQUIREMENTS FOR 1= 50� `o CRUSHER RUN AGGREGATE SIZE 25 AND 26, PER VDOT ROAD AND BRIDGE n SWM1 T 0 0 0 T F A L L PROFILE SPECIFICATIONS, SECTION 3oz.o3G. SHEET No. N 12 L F 4 x �O oo��� FILL TO BE PLACED AT > N o o� 6 7 g5or6 COMPACTION (TYP.) 675 oo � �lal»> �o � r z zz O~ 67 � o� 670 0 01� > 00� r7 � Z=p �Fzz SEE VSMP 6 6 PROPOSED GRADE (TYP.) SWM i OR DETAILS 66 660 ,� 15" RCP r�0 11.84 LF ® o~ x HM � MM 65 0 �� 655 0 M �Zo � �G®�1��0 (SLFi) REQ DB 65 `�~Z 650 6h6� 64 645 SAFETY SLAB (SL-s) REQ'D aM Ode 64 ®� 640 Sao 6 Op O NO WF 63 tea» 635 NFzz SAFETY SLAB (SL-i) REQ'D 6 3 EXISTING GRADE (TYP. 6 30 mo p H 6 2 � N o Na p0�0 >rnco.. � 625 to —0 62 `�~ZZ 620 SAFETY SLAB (SL-1) REQ'D 61 � G � 615 61 ���; 610 p0 O M O ZO / p� V7 � ZZ 60 � o~ 605 NO x N� SAFETY SLAB � �� N�Z� 60 I �N p p0 O~ 680 � " °° O oad� p c0 > oo� 680 co? O PROPOSED GRADE (TYP. N 675 azz -- 675 FILL TO BE PLACED AT 95%COMPACTION (TYP.) 670 670 TIE -INTO SWM FACILITY INV=667.50 665 665 15" RCP EXISTING GRADE (TYP. 13.42 LF ®5.59% 660 0�0 655 655 650 650 .t � n r+1 cn — t- � O O p 00 680 co0 680 � > � az 68D may-W$ O8� 6$z ' - - B2_ 684 Go Go 00 0 we 'o J� I I I I ,I ED �y 00 ti ' - - - - - - - - - - - - DRAINAGE DESCRIPTIONS ------------ 684m8mo Bi l a2--/--y/ ---- _ "° j® ( x / x ' - x / x RMTR I X -X -X r - - Al e i------ -- wo --- \ NQ -0 \ ..yy �� Z- A Nor p1 \\ - -- -- ~ ko - - - - - - - - - - - HATHAWAY STREET 54' PUBLIC R/9 EX 12" WA DB.3291 PC.607 \ems s -s �s J / -ns . co / _ .cb I I\ --`- �� J E2 10 rO _i �L-- - Ln E3 \rmrAaE� AGVZsn-MUMEnr - - - 6 66- 664 \ \ I 6) ` \ 662 - \\ 660 � \ \ - 658 \ \ \ \ 654 - / \ \\\ 650, - ` B - g `\\ - - - - - - 648. J64 �- \ 646°46� - \ -644'I v \ -640- 642 \ -640 - - 638 p' --__ 1 38 o \ 634 N - \ l 361 20 _ �- D 63 2 n I 34 - - " 6 1 32 O ►/MRLtn�� 1 N 1( � ❑ ----624 624 TP� z / /2 1 - e / 2 \ - 620 w . \ ti 618�lp....00 \ 31 � ry -626 ---- ,6�.- TI��E`OF ¢0NCENTRATIQNIPATH� o0 ---- z6C OF 'bLF v4/ EI�EV738'�& ^(70' OF ONC. iFLC 14 8- L 0 L/L� 6-0 V 594- �\ - --6041 / / / n SWM i \ %EL 602' - 2 , 5� 0 o 2-59 - STR. PIPE INFORMATION INLET INFORMATION NO DIA. in. LENGTH R SLOPE % INVERT IN INVERT OUT MATERIAL INLETTYPE Curb Type SLOT LENGTH RIM ELEVATION COMMENTS 11 DI-3C CG6 6' 689.18 VDOTSTD. IS-1 REQ'D - 15 62.29 2.47% 680.82 679.28 RCP 10 DI-3B CG6 6' 685.76 VDOTSTD. IS-1 REQ'D 15 75.52 1.69% 679.18 677.90 RCP 9 DI-3A CG6 4' 683.35 VDOTSTD. IS-1 REQ'D 15 39.00 1.00% 672.57 672.18 RCP 8 DI-3B CG6 6' 683.53 VDOTSTD. IS-1 REQ'D 15 63.96 1.00% 672.08 671.44 RCP 7 DI-3B CG6 6' 680.88 VDOTSTD. IS-1 REQ'D 15 60.44 0.91% 671.34 670.79 RCP 6 DI-3B CG6 6' 677.93 VDOTSTD. IS-1 REQ'D 15 27.97 4.00% 670.69 669.57 RCP 5 DI-3B CG6 6' 677.93 VDOTSTD. IS-1 REQ'D ' 15 51.78 2.99% 669.47 667.92 RCP 5A MH-1 CG6 - 674.82 VDOTSTD. IS-1 REaD 15 6.59 4.86% 667.82 667.50 RCP SWIM - SWIM 15 17.55 10.83% 667.50 665.60 RCP - 4A MH-1 - - 673.90 VDOTSTD. IS-1 REOPD 15 9.10 12.53% 663.60 662.46 RCP - 4 MH-1 - - 672.90 VDOTSTD. IS-1 REO'D SWM 1 MH-1 - - 673.39 VDOTSTD. IS-1 REO'D 15 11.84 4.56% 661.00 660.46 RCP - 4 MH-1 - - 672.90 VDOTSTD. IS-1 REQ'D 15 65.65 8.73% 656.46 650.73 RCP 3 MH-1 - - 660.90 VDOTSTD. IS-1 REO'D 15 67.47 8.00% 644.73 639.33 RCP 3A MH-1 - - 646.00 VDOTSTD. IS-1 REO'D - 15 61.78 14.47% 633.33 624.39 RCP 3B MH-1 - - 629.10 VDOTSTD. IS-1 REO'D 15 60.87 11.73% 618.39 611.25 RCP / / 3C MH-1 - - 615.90 VDOTSTD. IS-1 REQ'D 15 83.92 12.52% 805.25 597.25 RCP 3D MH-1 - - 601.90 VDOTSTD. IS-1 REQ'D / 15 87.75 8.58% 595.25 587.72 RCP 2 MHA - - 593.50 VDOTSTD. IS-1 REQ'D \ - - - 15 91.28 1.51% 587.62 586.24 RCP 1 MH-1 - - 591.17 VDOTSTD. IS-1 REQ'D 15 23.79 1.01% 586.14 585.90 RCP OUi 672 16 0- �0 / \'o A / / - - - - - - -- _ as -s6' \_ / 6$z / 648_- \ 646 646 P 638 -S3­lc 634)"W 3.10' L632- -.3D --__ ---- / \� 626---- 3 ,-624_---_ L - 622 6 3C `\ -�6. \\\ 6' k \\ 610 3 (5,\ 602 \ 600 -� 2 \\ S90 96 co 194 592 / NINE 0 MINIM S190 / NT OUT P � / / P _ - - - - 588 � __--GRAPHIC SCALE ----- ti � �` +DO 00, -- ----- `� 50 0 25 50 100 400 _ IMPRO ED-ASPHALT \ / / -DRIVEWAY \ - 84 - -ACCESS FOR (2) LOTS ----_--- lof = - I /S8 PROPOSED-V--SHAPED GRASS LINED DITCH TO \ \ \ - - ( IN FEET .� '`�► B LOCATED WITHI N VDOT RIGHT-OF-WAY, AS \ \� ' 1 inch = 50 ft. SHOWN. SE THISSHEETFORDETAILS. `\ / Structure Area (Acres) CW to (Min.) 1 0.00 0.90 5.0 2 0.00 0.90 5.0 SWM 2 0.00 0.90 5.0 3 0.00 0.90 5.0 3A 0.00 0.90 5.0 3B 0.00 0.90 5.0 3C 0.00 0.90 5.0 3D 0.00 0.90 5.0 4 0.00 0.90 5.0 4A 0.00 0.90 5.0 SWM 1 0.00 0.90 5.0 5 0.08 0.83 5.0 5A 0.00 0.90 5.0 6 0.09 0.83 5.0 7 0.08 0.85 5.0 8 0.03 0.70 5.0 9 0.28 0.66 5.0 10 0.08 0.78 5.0 11 0.08 0.79 5.0 12 0.25 0.76 5.0 13 0.25 0.54 5.0 14 0.11 0.68 5.0 15 0.30 0.76 5.0 16 0.16 0.68 5.0 17 0.32 0.71 5.0 18 0.11 0.85 5.0 24 0.00 0.90 5.0 25 0.00 0.90 5.0 OUT 0.00 0.90 5.0 ROOF DRAIN AND YARD INLET DESCRIPTIONS Upstream Structure Type Structure Size Rim Elevation Invert Downstream Structure Rim Elevation Invert Pipe Diameter Pipe Length Pipe Material Pipe Slope Al Inlet 12" 687.50 685.50 A2 685.50 683.00 8" 63.86 HDPE 3.91% A2 Inlet 12" 685.50 683.00 STR-13 680.80 677.12 8" 19.39 HDPE 30.33% Upstream Structure Type Structure Size Rim Elevation Invert Downstream Structure Rim Elevation Invert Pipe Diameter Pipe Length Pipe Material Pipe Slope B1 Cleanout 12" 690.00 688.00 B2 689.75 686.79 8" 67.00 HDPE 1.81% B2 Cleanout 12" 689.75 686.79 B3 689.00 684.65 8" 28.98 HDPE 7.38% B3 Cleanout 12" 689.00 684.65 B4 689.40 684.33 8" 64.1 HDPE 0.50% B4 Cleanout 12" 689.40 684.33 STR-12 687.85 683.96 8" 60.1 HDPE 0.62% Upstream Structure Type Structure Size Rim Elevation Invert Downstream Structure Rim Elevation Invert Pipe Diameter Pipe Length Pipe Material Pipe Slope B5 Inlet 12" 686.5 685.13 B6 688.2 684.79 8" 67.75 HDPE 0.50% B6 Inlet 12" 688.2 684.79 B3 689.00 684.65 8" 28.03 HDPE 0.50% Upstream Structure Type Structure Size Rim Elevation Invert Downstream Structure Rim Elevation Invert Pipe Diameter Pipe Length Pipe Material Pipe Slope C1 Inlet 12" 688.10 686.75 C2 688.00 686.25 6" 32.25 HDPE 1.55% C2 Cleanout 12" 688.00 686.25 C3 687.25 685.75 6" 24.44 HDPE 2.05% C3 Inlet 12" 687.25 685.75 C4 685.50 679.34 6" 50.64 HDPE 12.66% C4 Inlet 12" 685.50 679.34 STR-8 683.53 676.08 6" 83.4 HDPE 3.11% Upstream Structure Type Structure Size Rim Elevation Invert Downstream Structure Rim Elevation Invert Pipe Diameter Pipe Length Pipe Material Pipe Slope D1 Inlet 12" 683 681.5 D2 686.1 681.00 8" 23.38 HDPE 2.14% D2 Cleanout 12" 686.1 681.00 D3 682.67 680.24 8" 33.01 HDPE 2.30% D3 Inlet 12" 682.67 680.24 D4 680.10 678.00 8" 48.61 HDPE 4.61% D4 Inlet 12" 680.10 678.00 IDS 676.50 675.00 8" 44.31 HDPE 6.77% D5 Inlet 12" 676.50 1 675.00 1 D5A 671.00 668.86 8" 1 21.75 HDPE 28.2391 D5A Inlet 1 12" 1 671.00 1 668.86 1 STR-17 1 674.06 1 668.35 8" 1 50.93 HDPE 1.00% Upstream Structure Type Structure Size Rim Elevation Invert Downstream Structure Rim Elevation Invert Pipe Diameter Pipe Length Pipe Material Pipe Slope E1 Inlet 12" 681.00 679 E2 680.25 678.00 8" 44.00 HDPE 2.270 E2 Inlet 12" 680.25 678.00 E3 678.1 676.00 8" 38.02 HDPE 5.26% E3 Inlet 12" 678.1 676.00 STR-16 672.88 668.60 8" 53.32 HDPE 13.88% Upstream Structure Type Structure Size Rim Elevation Invert Downstream Structure Rim Elevation Invert Pipe Diameter Pipe Length Pipe Material Pipe Slope 19 Inlet 24" 651.50 645.00 20 637.5 633.69 8" 122.09 HDPE 9.26% 20 Inlet 24" 637.5 632.69 21 617.5 613.55 8" 112.61 HDPE 14.33% 21 Inlet 24" 617.5 612.55 22 605.87 602.33 8" 67.01 HDPE 15.25% 22 Inlet 24" 605.87 602.23 23 600.90 596.37 8" 49.71 HDPE 11.79% 23 Cleanout 1 24" 600.90 1 596.27 23A 593.68 590.69 10" 91.35 HDPE 6.11% 23A Cleanout 1 24" 1 593.68 1 590.59 SWM-2 - 1 590.47 10" 1 11.82 1 HDPE 1.00% Q 2=1.04 CFS DL=12- \ V,=3.39 FPS 3 1 Q,o 1.34 CFS GRASS D,o 0.35 FT (SLOPE=5.8%) DITCH 590 NO SCALE PROPOSED 12" DEEP FESCUE GRASS -LINED V-SHAPED DITCH WITH 3:1 SIDE SLOPES. PER VESCH TABLE 5-14, THE MAXIMUM PERMISSIBLE VELOCITY IS 4 ft/s 590 EXISTING GRADE 585 / 85 PROPOSED AVON STREET EX ENDED r DITCH CEN ERLINE / 580 580 CONTRACTO SHALL TIE PROPOSED AVON STREET EXTENDED DITCH INTO EXISTING DITCH & DOWNSTREAM CULVERT LOCATED AT THE SOUTHERN PROPERTY CORNER. CONTRACTOR TO TIE BACK GRADES AT 3:1. 575 CONSTRUCTION TO BE LIMITED TO THE D 75 SUBJECT PROPERTY & PUBLIC R/W, AS SHOWN. m r, o m ' 00 N kD 00 00 'i, Cc PROFILE SCALES 0+00 0+50 1+00 1+50 I"=5' (V) 1"=50'(H) AVON ST. EXTENDED DITCH PROFILE Road Name: Avon St. Extended Roadside Ditch Ditch Side: South of Proposed Entrance Job Number: 182156 Designed By: FGM DRAINAGE AREA DESCRIPTIONS Drainage Area Area (Acres) CW Al 0.15 0.54 A2 Bl 0.14 0.90 B2 B3 B4 B5 B6 C1 0.12 0.60 C2 C3 C4 D1 0.20 0.60 D2 D3 D4 D5 El 0.17 0.65 E2 E3 19 0.18 0.40 20 0.15 0.50 21 0.08 0.53 22 0.33 0.41 23 0.00 0.00 23A 0.00 0.00 Checked By: SRC Sta From Sta To T (min) C Value Area (ac.) CA (accum) I (in/hr) Q (cfs) Slope (ft/ft) Grass n=0.03 Jute Sod n=0.05 Paved n=0.015 1' (in/hr) Q" (cfs) Depthl0 (ft) Min.Design Depth & Lining Top Width (3:1 Sides) (ft) Vel. I Depth VeL Depth I I Depth 0+00 1+25 13 0.35 0.80 0.28 3.7 1.04 0.058 3.39 fps 0.32 ft 4.80 L34 0.35 ft 12" Grass 6.00 ft Note: Proposed ditch to tie into existing ditch & culvert at southern property corner. Lie. No. 035791,E 8/26/21 44i F- Z w O U Z Z Z Q J Q 0 Q U 0 u U � m 5 L7 w In J Z � u Z Z O � w (n Z .. p W a /rWof / �rrr ti ti v � Ln 00 In_ ti M ® M rn N M N W CDN W z � N z Q O > �. w w a J J 0 LU � J J 0 z J 1-1 Q LL Z 2 I Q W " Q Y ~ LU Iti L U UlU) la- Q z z I w Q' O I Z 0� w NN I..L U) Q 0 iJ J< 0 LU U I w a JOB NO. 112066 SCALE AS SHON - SHEET NO. 13 INLETS ON GRADE, DESIGN (CURB SPREAD AND INLET CAPTURE) Intensity 4.00 (Intensity is 4 in/hr for spread, and 6.5 in/hr for capacity and depth) Mannin s Coefficient, n is 0.013 Inlet Hydroloqy Curb and Gutter Inlet x a o j x rn o U v O- O O G ^ r O N 42 9 N ^ v N ^ O N U N L v v y L N U 3 K W 3 C v C 2 v m c r > o y E Z^ ° x 2 r' oo w m O H ❑ @ E ?i d > J -I U U d d d rn 00 rn rA H W m rn rn J J W a d K 5 3B 6.0 0.08 0.83 0.066 0.27 0.13 0.40 0.0619 0.0200 2.0 0.0830 4.1500 3.36 0.99 3.5120 0.1463 0.1649 1 0.99 0.39 0.01 18 6 3B 6.0 0.09 0.83 0.075 0.30 0.00 0.30 0.0619 0.0200 2.0 0.0830 4.1500 3.01 0.99 3.5120 0.1463 0.1649 3 1.00 0.30 0.00 - 7 3B 6.0 0.08 0.85 0.068 0.27 0.00 0.27 0.0480 0.0200 2.0 0.0830 4.1500 3.05 0.92 3.5120 0.1463 0.1546 1 1.00 0.27 0.00 - 8 3B 6.0 0.03 0.70 0.021 0.08 0.00 0.08 0.0380 0.0200 2.0 0.0830 4.1500 2.05 1.00 3.5120 0.1463 0.1663 4 1.00 0.08 0.00 - 10 3B 6.0 0.08 0.78 0.062 0.25 0.00 0.25 0.0490 0.0200 2.0 0.0830 4.1500 2.94 0.99 3.512 00.1463 0.1649 9 1.00 W1.00 0.25 0.00 - 15 3B 6.0 0.30 0.76 0.228 0.91 0.00 0.91 0.0480 0.0200 2.0 0.0830 4.1500 4.80 0.89 3.5120 0.1463 0.1502 6 0.85 0.78 0.13 5 13 3B 8.0 0.25 0.54 0.135 0.54 0.00 0.54 0.0159 0.0200 2.0 0.0830 4.1500 4.85 0.90 3.5120 0.1463 0.1517 3 1.00 0.54 0.00 5 14 3B 6.0 0.11 0.68 0.075 0.30 0.00 0.30 0.0159 0.0200 2.0 0.0830 41500 389 0.95 3.5120 0.1463 0.1590 1 1.00 0.30 0.00 5 - for inlets draining to stormwater management facilities, where overland flow to facilities is not available, 100% capture is required at 6.5in/hr INLETS ON GRADE, DESIGN (CURB SPREAD AND INLET CAPTURE) Intensity 6.50 (Intensity is 4 in/hr for spread, and 6.5 in/hr for capacity and depth) Mannin s Coefficient, n is 0.013 Inlet Hydrology Curb and Gutter Inlet j N .2 m o � o � c w C 0 v N O L c L N x §` w o m O 3m > C O L U CD f b N O E E a U aG io in � O > ¢ ti C7 C7 to 3 rn rn H W d in E ui O c10, of 5 3B 6.0 0.08 0.83 0.066 0.43 0.40 0.83 0.0619 0.0200 2.0 0.0830 4.1500 4.42 0.92 3.5120 0.1463 0.1546 9.32 0.64 0.84 0.70 0.13 18 6 3B 6.0 0.09 0.83 0.075 0.49 0.00 0.49 0.0619 0,0200 2.0 0.0830 4.1500 3.62 0.97 3,5120 0.1463 0.1619 7.27 0.83 0.96 0.47 0.02 17 7 3B 6.0 0.08 0.85 0.068 0.44 0.00 0.44 0.0480 0.0200 2.0 0.0830 4.1500 3.66 0.97 3.5120 0.1463 0.1619 6.45 0.93 0.99 0.44 0.00 - 8 3B 6.0 0.03 0.70 0.021 0.14 0.00 0.14 0.0380 0.0200 2.0 0.0830 4.1500 2.46 1.00 3.5120 0.1463 0.1663 3.61 1.66 1.00 0.14 0.00 - 10 3B 6.0 0.08 0.78 0.062 0.41 0.00 0.41 0.0490 0.0200 2.0 0.0830 4.1500 3.53 0.98 3.5120 0.1463 0.1634 6.23 0.96 1.00 0.41 0.00 - 15 3B 6.0 0.30 0.76 0.228 1.48 0.00 1.48 0.0480 0.0200 2.0 0.0830 4.1500 5.76 0.84 3.5120 0.1463 0.1429 11.56 0.52 0.73 1.09 0.40 5 13 3B 8.0 0.25 0.54 0.135 0.88 0.00 0.88 0.0159 0.0200 2.0 0.0830 4.1500 5.82 0.84 3.5120 0.1463 0.1429 6.66 1.20 1.00 0.88 0.00 5 14 3B 6.0 0.11 0.68 0.075 0.49 0.00 0.49 0.0159 0.0200 2.0 0.0830 4.1500 4.66 0.90 3.5120 0.1463 0.1517 5.01 1.20 1.00 0.49 0.00 5 - for inlets draining to stormwater management facilities, where overland flow to facilities is not available, 100% capture is required at 6.5in/hr Desial Year: 10 Proiect: Avon Park II Job #: 182156 Prenaredbv: LMW.PE • : 1 . • ®� 1 11 I III ��_---_--____-- INLETS IN SUMP, DESIGN (CURB SPREAD AND INLET SPREAD AND DEPTH) Intensity 4.00 (Intensity is 4 in/hr for spread, and 6.5 in/hr for capacity and depth) Mannin s Coefficient, n is 0.013 Inlet Hydrology Curb and Gutter Inlet >' 2 N N C Cw 'e n `. yy cO 13 � S � v O1 rn � 2 � iii S L ❑ @ c - w 9 m E a > ¢ u cai O a v; r i 3 v3i w° all 0.28 0.66 0.185 0.74 0.00 0.0010 0.0200 2.0 0,0830 4.1500 9A7 0.62 STR 9 DI-3A 4.0 combined flow 019 0406 931 all 0.08 0.79 0.063 0.25 0.00 0.0010 0.0300 2.0 0.0830 2.7667 4.76 0.84 F0.74 STIR 11 DI-3C 6.0 combined flow 007 0152 232 all o25 0.76 0.190 0.76 0.00 0.0010 0.0100 2.0 0.0830 8.3000 14.29 0.54 STR 12 DI-3C 12.0 combined flow 0.8 0.09 1 0.199 9A2 all 0.16 0.88 0.109 0.44 0.00 0.44 0.0010 1 0.0190 1 2.0 1 0.0830 4.3684 7.76 0.70 STR 18 DI-3C T 6.0 combined flow 0.4 0.10 0.218 5. 55 all 0.32 1 0.71 1 0.227 0.81 0.00 0.91 0.0010 0.0500 2.0 0.0830 1.6600 5.59 0.73 III STR 17 DI-3C 6.0 combined flow 0.9 0.11 1 0.236 2.17 all 0.11 1 0.85 0.094 0.37 0.01 0.38 0.0010 0.0500 2.0 0.0830 1.6600 4.01 0.87 Carryover from STR-5 STR 18 7DI-3C 6.0 combined flow 0.4 1 0.09 1 0.199 1 1.82 * gutter longitudinal slope of 0.001 should be used in a sump condition - grate inlets (DI-7) in open pavement areas will not have a curb spread, but will have inlet spread and depth - for inlets draining to stormwater management facilities, the 6.5in/hr check storm will suffice for the 10yr conveyance to the facilities NOTE: Inlet size for structures determined by overland flow. Pipes have been sized to include overland flow as well as yard inlet and roof drain drainage areas Design Storm Year = 10 INLETS IN SUMP, DESIGN (CURB SPREAD AND INLET SPREAD AND DEPTH) Intensity 6.50 (Intensity is 4 in/hr for spread, and 6.5 in/hr for capacity and depth) Mannin s Coefficient, in is 0.013 Inlet Hydrology Curb and Gutter Inlet m a � ^ v CO ! c o � d o € w e L o € `s t - m a 0 10 0 �' c o 2 22 . - >S c10i S 5 1° Sw w y w ? >S 15 a 0 5 0 e w w w > J Q Ci U or Of 6 of in 3f F w° 96 a H all 0.28 1 0.66 0.185 1.20 0.00 1.20 0.0010 0.0200 2.0 0.0830 4.1500 1 11.00 1 0.52 STR 9 13I-3A 4.0 combined flow 1.2 0.26 0,562 12.87 all 1 0.08 1 0.79 10.0631 0.41 1 0.00 0.41 0.0010 0.0300 1 2.0 1 0.0830 1 2.7667 1 5.71 0.79 STR 11 DI-3C 6.0 combined flow 0.4 0.10 0.210 3.20 all 1 0.25 1 0.78 0.190 1.24 0.00 1.24 0.0010 0.0100 2.0 0.0830 8.3000 17.14 0.43 STIR 12 DIJC 12.0 combined flow 1.2 0.13 0.275 12.80 all 1 0.16 1 0.68 10.1091 0.71 1 0.00 0.71 0.0010 0.0190 2.0 0.0830 4.3684 9.31 0.60 STIR 16 DI-3C 6.0 combined flow 0.7 0.14 0.301 7.26 all 1 0.32 1 0.71 0.227 1 1.48 1 0.02 1.50 0.0010 0.0500 2.0 0.0830 1.6600 6.70 0.54 Carryover from STR-6 STR 17 DI-3C 1 6.0 combined flow 1.5 0.15 0.327 3.00 all 1 0.11 1 0.85 0.094 0.81 0.13 0.74 0.0010 0.0500 2.0 0.0830 1.6600 4.81 0.79 Carryover from STR-5 STR 18 D153C 6.0 combined flowl 0.7 1 0.14 0.310 2.84 * gutter longitudinal slope of 0.001 should be used in a sump condition - grate inlets (DI-7) in open pavement areas will not have a curb spread, but will have inlet spread and depth - for inlets draining to stormwater management facilities, the 6.5in/hr check storm will suffice for the 10yr conveyance to the facilities NOTE: Inlet size for structures determined by overland flow. Pipes have been sized to include overland flow as well as yard inlet and roof drain drainage areas MMWM=MWMW �----_-_- ®-SEE VSMPFORSWM I ROUTINGS �- 1 1 1 1' 1 1 1 1 11 1 � • r �--_-_-_- j> v1 �f � SCOTT R. LINS� Lie. No. 035791,'n p 8/26/21 c4 o�5'Innret. E�C'l� Z Z w f Q U ..ww Vl Z Z Q J Q 0 Q U OIl CC w m _ L7 0 in J Z Ln u Z .a-, F In w >O to Z p W C a J C Ell In W N r4 N ~ 7 � in r .7 ON rw W CV C> M CV W < w J J Uj U, 0 Z Q U Wr w ZLU w _U) lu Q 0- I 0 Q z O Q D J U Lu w a 1u) JOB NO. 112066 III _ 501 14 705 705 700 700 GRADE (TYP.) 695 /--EXISTING 695 690 690 DISC l-H HT. OF (-%C2NC0p, OBJ=3.5' QQQ) SIGHT LINE (TYP.) 685 HT. OF 685 YE=3.5' _ - DIST ANCE-280' SIGHT 680 PRO POSED GRADE (TYP.) HT. OBJ=3.5' 680 675 675 670 670 665 665 1� Ol 0 Ol rl 0 N M M N n !+'1 M 00 H S lN+1 N r! l(1 00 0 l0 0 Cl 00 00m do 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 DESOTO DRIVE (WEST) & HATHAWAY STREET INTERSECTION SIGHT DISTANCE PROFILE PROFILE 700 700 695 EXISTING GRADE 695 (TYP.) 690 S/ �/St GNt (t0 690 HT. OF OBJ=3.5 F/VD�CF�1 0' OF 0 ROAD) SIGHT LINE (TYP. 685 _ 685 HT. OF YE=3.5' DISTgN SIGHT E=280' 680 HT. OF? 680 ROPOSED GRADE (TYP.) OBJ-3. 675 675 670 670 I* M 0 N � , O 00 n'1 cn � 1Mj M 1Y O 00 p COOO l0 ,y O O� CO li ci W O1 00 01 00 N 00 'D 00 l0 10 l w lD 'D ID w w 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 DESOTO DRIVE (EAST) 8c HATHAWAY STREET INTERSECTION SIGHT DISTANCE PROFILE PROFILE VERTICAL GRAPHIC SCALE 5 n 2.5 5 10 50 ( IN FEET ) 1 inch = 5 1t. HORIZONTAL GRAPHIC SCALE ( IN FEET ) 1 inch = 50 ft. 20 Lie. No. 035791,E 5/24/21 44' ZZ C~ k 0 U m V D w 1n 0 J Z .a. O 1-- En z W ~ Ce In_ w w 7 U, Ul M m N 4 M N CD rn N LU J J U) LU J 2 U Y w U) Lu LU U) mow/ 0f Q 0 0 N (/1 W z J Q L.L J O 0- LU a_ LU a J Q Ln z o 1--I LL �--- 1 Y z oc O Q � V z w O L > w z I Lu O w x o_ v) JOB NO. 112066 SCALE III _5O1 SHEET NO. 15 z, - County of Albemarle CONSERVATION PLAN NOTES: NOTE: ALL LANDSCAPING EASEMENTS, BUFFERS, AND SCREENING TH Conservation Plan Checklist- To be placed on Landscape Plans O T (Handbook, PIP HI-284-111-297 for complete specifications) 1.ALL TREES TO BE PRESERVED AND PROTECTED SHALL BE MARKED WITH PAINT OR RIBBON SHALL BE PLANTED IN ACCORDANCE WITH THE APPROVED PROFFERS. AT A HEIGHT CLEARLY VISIBLE TO EQUIPMENT OPERATORS. NO LAND DISTURBING LANDSCAPING SHALL BE INSTALLED PRIOR TO THE FIRST CERTIFICATE / I / / �t 1. 1herouorineilemsshall bo,lavananthe mmn: ACTIVITY SHALL BEGIN UNTIL THE TREE MARKING HAS BEEN INSTALLED BY THE 1 Emerald entinel' astern edcedar OF OCCUPANCY FOR ANY PROPOSED UNITS WITHIN THE / I � 'frees tobasavea; CONTRACTOR AND INSPECTED AND APPROVED BY THE COUNTY ENGINEERING DEPARTMENT. �� 4-'Little Gem' Ma / ® imrsof emnx(onrsided ptineofo-eestobesavea); gn01'a PROPOSED 20' LANDSCAPING EASEMENT - NATURAL / SCOTT R. LINS'Z ® Location and type ofprotecavefenang; 2. HEAVY EQUIPMENT, VEHICULAR TRAFFIC, AND THE STORAGE OF CONSTRUCTION DEVELOPMENT AS DETAILED IN PROFFER 3. �-' ellie R. Steven Hall O El Grade changes requiring tree wells or walls; MATERIALS AND SOIL SHALL NOT BE PERMITTED WITHIN THE OUTSIDE DRIPLINE OF TREES ' Eastem- Redeedor LAN DSCAPED AREA OR REPLANTING/NEW TO BE PRESERVED AND PROTECTED. - - - - t / U Lie. No. 0357911'1 El Popo oao-e onngoramassingbeyonamelmtsofoleadng. Nel�ie R. Stevens' y LANDSCAPED BUFFER FOR ANY DISTURBED AREAS 2. Mammies: 3. TEMPORARY EROSION CONTROL MEASURED AND ,OR PERMANENT STORMWATER 1 / DB, PG. / "O.r/i 8/26/21 CV4' 0 ABuses tobesaved shall beranked with pectordbbonatsheightoleadyv,sibletoegwpmentoperatom. MANAGEMENT FACILITIES LOCATIONS SHALL BE COORDINATED SUCH THAT THEY SHALL NOTE: SCRIM FENCING TO BE INSTALLED IMMEDIATELY FOLLOWING n El No grading shall begin rualthe tcemarking has been impaired andapprovedbyaCounryfnspector. NOT ADVERSELY AFFECT TREES TO BE PRESERVED AND PROTECTED. GRADING IN THE LOCATION WHERE THE SCRIM FENCE IS TO BE 1�m=o \ / / �SSIONAL o-mF'�Oti s. PreCon•uon conference: 4. FIRES SHALL NOT BE PERMITTED WITHIN 100 FEET OF THE OUTSIDE DRIPLINE OF TREES LOCATED. ZI Tree preservation and protection measures shall be reviewed with the contactor on ate. TO BE PRESERVED AND PROTECTED. 4. EaulumeatOueratIm.naStoraae: 5. TOXIC MATERIALS SHALL NOT BE STORED WITHIN 100 FEET OF THE OUTSIDE DRIPLINE OF LANDSCAPING NOTES: is 93 Heavy, equipment, vehicular traffic and storage efconstrucbon materials including soil shall not be permitted within the dripfines oftees TREES TO BE PRESERVED AND PROTECTED. 1. STREETTREES PROVIDED So'O.C. AND 5'-lo'FROM PROPOSED UTILITIES. �I \, 1 I I \ W be saved. 2. ALL SITE PLANTINGS OF TREES AND SHRUBS SHALL BE ALLOWED TO REACH, AND BE • --�--� '�'�. 1- on low Sweet Bay Ma olia I I 6. NO LAND DISTURBING ACTIVITY SHALL BEGIN UNTIL THE TREE PROTECTIVE FENCING HAS 9 Y 9 & Soil Erosion and Storms ater Detention Devices: - - MAINTAINED AT MATURE HEIGHT THE TOPPING OF IS PROHIBITED. SHRUBS - - - -.--- -. BEEN INSTALLED BY THE CONTRACTOR AND INSPECTED AND APPROVED BY THE COUNTY - a~ S 24" CMP 1 I ® such devices shall not adversel affeottreestobesaved. ENGINEERING DEPARTMENT. AND TREES SHALL BE PRUNED MINIMALLY AND ONLY TO SUPPORT THE OVERALL soli r` _ _ � \ r-----;, I I \ PROPOSED 20' �( I � - � \ 1. 6. Fir": 7. WHEN TRENCHING FOR ANY KIND OF UNDERGROUND WATER, SEWER, ELECTRICAL, CABLE, HEALTH OF THE PLANT. EMERGENCY ACCESSTOTAL STREET FRONTAGE- 6 &] fnesarenotpermittedwithin100feetofined:iphasoftreestobesaved. TELEPHONE, OR OTHER UTILITY SERVICE IS NECESSARY WITHIN THE LIMITS OF TREE 3 -9 4 F� EASEMENT I PROTECTION OR BEYOND THE LIMITS OF CLEARING, THE SEPARATION FROM THE TRUNKS REQUIRED STREETTREES: 21(iTREE PER EVERY 5o'OF STREET FRONTAGE) \ I 7. KI Toxiateraten OF TREES SHALL BE MAXIMIZED TO THE FURTHEST EXTENT POSSIBLE. TUNNELING SHALL PROPOSED STREET TREES:2 \ DB. PG. _ \ ® Toxicmateaals shot not bestor�witltin 100 feet ofine mi line of trcesmbe caved. 3 W $Wee Bay M gn0110 P BE REQUIRED WHEN DEEMED, BY THE COUNTY ENGINEER, THAT TRENCHING WILL P NOTE: 278' OF STREET FRONTAGE ALONG HATHAWAY STREET SIGNIFICANTLY DAMAGE FEEDER ROOTS OF TREES TO BE PRESERVED AND PROTECTED. / R Prote iePename: REQUIRED STREET TREES: 6 O / \ \ \ z Trees to be retained within 40 feet of s proposedbuilding orgreding activity shall be protected by fencing. \ \, I \ \ 0 aerra shaubern ]arxaaashadbe�s ecteaanaa edb eomr ]as error m h,rcaaa 8. ANY DAMAGE TO THE CROWN, TRUNK, OR ROOT SYSTEM OF ANY TREE TO BE / PROPOSED STREET TREES: 8 ng p p ppr°° ya ty p prior gaaiagorroas PRESERVED AND PROTECTED SHALL BE REPAIRED IMMEDIATELY, IN ACCORDANCE WITH NOTE: 382'OF STREET FRONTAGE ALONG DESOTO DRIVE 9. neeweus: THE PRACTICES IN THE EROSION AND SEDIMENT CONTROL HANDBOOK. CARE FOR SERIOUS INJURIES SHALL BE PRESCRIBED BY A PROFESSIONAL FORESTER OR TREE SPECIALIST. REQUIRED STREET TREES:8 Lin \\� \\\J \ Q \ O LI When the ground level must be rased within the dripline of a use to be saved, a has well shall be provided and a construction detail PROPOSED STREETTREE5:6 `I I U submitted for approval. \ \ at\ 9. SOILS WHICH HAVE BEEN COMPACTED, OVER THE ROOT ZONES OF TREES TO BE NOTE: 200' OF STREET FRONTAGE ALONG ANOKO COURT _ 14. Treewaur: PRESERVED AND PROTECTED, SHALL BE AERATED BY PUNCHING HOLES WITH AN IRON m \ I REQUIRED STREET TREES: tr - - J El When The gmundlevel must bemwereawithin meddpl;aeabeembesou.a,aheewausl.allbaproaaea;a.aaaoonsmrenondead BAR EVERY 18" OVER THE ROOT ZONE. THE BAR SHALL BE DRIVEN 12' DEEP AND z z subndtted par approval. MOVED BACK AND FORTH N EACH HOLE UNTIL SOIL S LOOSENED. \ PROPOSED STREET TREES: 4I \ �\ \�� \ Z Q OU O tt. irenchmeand 7unnehne: I 10. TREE PROTECTIVE MEASURES SHALL BE THE LAST OF THE TEMPORARY EROSION NOTE: 10q'OFSTREET FRONTAGE ALONG PRIVATE ACCESS EASEMENTMT \ �\ c*� - d k w 0 When leaching is required within the Emits ofclearing, itshall bedone asfar away from the trunks of tries aspossible, Tunneling CONTROL PLAN MEASURES REMOVED DURING THE FINAL CLEAN-UP. REQUIRED STREETTREES:3 LOT 30 --- - _ V �'� \ \ O U P- PROPOSED STREET TREES: 5 msder a large tree shall be consrdared as an altemahva whenrt rs anhciparad that accessary berthing will destroy fader roots. 5 \ ' -- , � � � � -, � �\ � � � � (D PARKING LANDSCAPE REQUIREMENTS y--4 I O w (n z_ 12. Cleanup; 4' � o.86 ACR ) � \ \ (n Hd � REQUIRED PARKING LANDSCAPING = 21 PARKING SPACES Qa 1 TREE / 10 SPACES \ (n ® Protective fencing shall be the feet hems removed dunng the final cleanup. I z ti W =3TREES REQUIRED � � \ \ � H O H- ts. Damaeearrees: I / TOTAL TRESS PROVIDED ADJACENT TO PARKING SPACES = 3 TREES PROVIDED to z 0 ® Damagedtreeasball treated immediately bypmning,feraliutionoroNermethodsrocommendedbyao-eeapedalist S. SEE SHEET SA FOR TREE PLANTING& STAKING AND TREE FENCING&ARMORING \ \ \ �Z. > .. NOTE: Ii IS EHE DEV OPER'S RESPONSIBILITY TO CONFER WITH THE CONTRACTOR ON TREE CONSERVATION / DETAILS. LPL \ \ \ \ 1 I W a Of REQUIREMENTS. � 1 PLANT SCHEDULE \ ` \ \ \�4)AKITREEITREES� ��2� Q , ALONG AVON �STREE f� EXTEND �- 8/26/2021 I W \ E OWNER SIGNATURE (DATE) �o I ti U CONTRACT PURCHASER SIGNATURE (DATE) 5/l/06 Pape 1 of 1 2o' GRADING EASEMENT 1• C I - DB.3291 PG. 607 'I M I -.nv \ \ 1 I a III i � to q � STREET TREES &PARKING LANDSCAPING PLANT SCHEDULE PROPOSED 2o' DRAINAGE AND Quantity 68 'Nellie R. Stevens'Holly 60 Juni erus vir iniana'Emerald Sentinel''Emerald sentinel, Eastern gedcedar 8_10' 23 Magnolia randiflora'Little Gem' 'Little Gem' Ma nolia 10 Magnolia vir iniana 'Jim Wilson' Moon low Sweet Bay Magnolia 13 Thu'a'Green Giant' 'Green Giant' ArbQrvmtae 8-10' WA 11111111 • ENT �Allll SCAPE BUFFER .• • �•. • -• ■: .• 1 n •I : Cal/ I • i p / •, • •I V TIMP 90E-9 N/F IGNACIO 0 NIF IAN FARIS\ • • TRUST , FENCEPROPOSED SCRIM FENCE (LANDSCAPED BUFFER AREA) TMP 19101-301 ALONG •, r PROPERTY .: I t : istt •. • •• • tt 1191• .• •' ... ell Eastern R MAL PROPERTY INC (y) r __ • •• •- _ • • _ _Eastern •_• -•• G _ _ _ _ •'Emerald _ _ • _ _• -•• li ILI ILI •• • • _ _ _ _ • �thll\.-.` ! _ _ _ _ AVIDi..Aumn AYIDn _ _ _ _ _ _ _ _ , ._ _ar w. arm. •o ►f `A �,• YI'� f"SN,^ . I� w♦ /7 �9 `s���r.,. aKsau�mnirm������•.-ram.--arrs� �,I. �- - l' :r $r ��■�•, I ♦•�N•V'Y.v2�/:JVi,� I ♦ _- A F :i.i" I • ■ ■ n ■ {r ' ., i� \: „' 'I 111 / r ♦ 1vr �VI•r_ �IfIO. 7 �I y,:, ryf'. �.�► „y `D �i�� i / ,1� 1 . 'i �... l� I�1� .l /�% �i / l Si ,. T .l • 11/ 11 r .. �•..�__ �vn. .f...i�.ltl:t�!_t+�.,Za��l/ �I��//s1//67f,:� t,,�y/♦ 7 rJ��llf ill ,, ,_ V s i nr� ! V �. @ � im r !' /.., /. 's�9_ 1. i \ •�•1 III ;. .,... a _ �L- y�� ..... .� ,UN � s r �.� .. �III ! / _,-_� i 7In {t, 4lr!� 0/�.�.a .t , �eEr.__.hli�._.ue3.r) a�/�► �n_-. e. /._.a .�:. w■ , 3Ii[S�VL�II•I/YJ 11f.•.� Li _= G _ .\ ,., r !%l. .. , �.../♦.�'.Si 1J < Y(iv �,. .r.. I� .__��ii'���.. �, J%� , /e •l (�: r,. ...: _S i�/�.,' �J�t,!Lp{1��g. �1 p 'n,e� '� .:• ��! ��,..--t �•_. i s :...): \; ._ '•C,, u. {.I�r- ♦ ... u11,� / •h111`'1 i I �s .�V �p_�i; C `�;\ . -... �,�I/,f� � \� ., S�E'rlii. \`""%��l 1. .... ► i1 .i li I��J�.� . �� � " Sir ,.r - c , �„ �( � _ IEIk\iLiIYiI� ilia s - _ r , < ,i�1�� i�/�.Anm�0�1�, ��1III,S,yl►� Ili �1� �' < -.:c , s� - \� -- - � �i� - ��� ���� I I <r. v,u�� 'YII•� sar ,.,). ��� �� �'._\_�� �1����_If/'Ir�����CV��Vll._ r ���t__��<.�■Y \�!:�t� r 11 �� • e ■ ■ ■ . c n . ■ • . as as as a a It ■ ■ ■ . ■ . •• LU • • • • LOT[M-�E �� k ��) ) �'. •`� r� • .: 7 LOT L9 • • r® �I Lw�t� -���� /• Ear. :r: :� -v--r' I IIIIII� ..LIJ _ .�1ff�ll�tfl���. ��llA�'i�l�■■�����r��■�ll��� I� i I IIIILLI • � I =� i. ��r. � � %ii��■! � �i. �l�i�■ III ; � .... �Il�o���►■ LIJ WIN st I,� _�+ , I,� III,, - b�...-� �� _.� • 1 . ,� tn. J�!y., !.,:Ila(Ttl■L___�%Vi.- �!�wJ.�_IiVIn ��` '�<D. �.�74UI1_��,.II�-Y _l�'. rr0/n� r• 1 i e1VY♦/i 114M.2000111 / 1 •. rr. :Yn.,-�. .r , r F `�1gig •' unasrarr.7nA • nc. ,� r, .3 !-...,�1,1L-.JPLi.S1US1>/�YIIn.FS%%aL,r•NI//.7w/ ► . •i; L' r f / !( � /,. 7 `•, �l !a• l i ' •-T ,7F. � I'^ I 1 7e / • � »,.ems � t. r .�, / .. .-Rt" _•./■i f.. IC �If�ll /�'► 11. o► �'� r L11, ���il �L" -1�' ca„ v -,� ,.,fir.. .f�.• T t n _ _pp,ff qq. � .yT . .• ,,._ T . .. 1. / �al� mii r �� �. �, � _ � •, I •� ♦ / - .%_ < /� vi�,� i)t {) ✓i a m1,♦ rtCc r i _ /1. °'o_J. /�.Q :, _ _ c, �fp /:. <.. ../• = / �. L' . /- _. -! ) • \1 $ \ A� _ .1;. /✓ ..� . �i .... a/.� .. .... % /a. c, �l /, • ,j� C�� _ _ . ...'.^\� �j/ C$• _�, .., .., • - \ •� e/ _. _ _ - 1•i , �. _. „ .. ,.. ram• c _ _. - .. ,,.. �. - ��, .. I i ,► •e _.J.i.-. l r/ �.. > � , _ _ ��f � , , .� 5 •� � r , � -. � �. • i � � :.. ,. ,. \ � \ ,h� l� _ � ,• ,_ _��... , ... __1, _ , , . ,_, < . ,. , , , . � �.�_��,��_�1�����►�f_.�,�2><,����,«,rb__ i p� - r v v d �' v v . v w- v -irate w- V p_ "r•p_ -- - -- w' w �Q�B illN �ur� otV1Hh ����1� �YW �� TREES • .: • Little Magnolia ••• LANDSCAPING TREES L,7, ANOK8 COURT •••• ■ . ■ •III 6-'Green Giant' .. •.:.. Arborvitae' - TMP .l I • :•••D:•FENCE �. (3)AR STREET TR / :'ll �.TREET NCOPRIVATE STREET j l: 4858 PC •l. • ALONGNOTE: ALL STREETS WITHIN THE DEVELOPMENT SHALL BE MARKED HATHAWAY STREET FENCE -.• TMP .l IA WITH NO PARKING SIGNS ON BOTH SIDESOF ROADWAY.• . • • • • ••.• I 1. MYRTLE T BROOKS HATHAWAY STREET SHALL BE MARKED WITH NO PARKING SIGNS ON /: • PC 39ONE SIDE OF THE ROADWAY. 7 b.0 SYM BOTANICAL COMMONNAME SIZE CANOPY(SF) TOTALSITE QUANTITY ICOVERAGE (SF) AR ACER RUBRUM RED MAPLE 1 13/4" 1 397 18 1 7,146 UA ULMUSAMERICANA AMERICAN ELM 1 13/4" 1 397 12 1 4,764 � a / T11P 90-30B I / lk'/F JOHN A OR RUBY T BR00 p w / D Lu 1191 PC 396 I I I CRAP IC SCA4E Joe No. 7 / 112066 I I I 30 0 0 30 60 / 0 hill/ SCALE 111 = 301 ( IN FEET ) i SHEET NO. inch = 30 /It. ��y I1�}�� 16