Loading...
HomeMy WebLinkAboutSUB202100084 Plan - Revision 2021-11-12OLD TRAIL VILLAGE -BLOCK 7C SITE DATA: TAX MAP PARCEL: 055EO-01-7B-00000 MARCH MOUNTAIN PROPERTIES LLC DB 4954 PG 18C ADJACENT PARCEL INFORMATION: 055EO-01-7A-02600 SOUTHERN PROPERTY LLC DB 5071 PG 231 055EO-01-35-000D1 MARCH MOUNTAIN PROPERTIES LLC DB 5024 PG 441 055EO-01-00-000AO MARCH MOUNTAIN PROPERTIES LLC 055EO-01-3A-00100 MARCH MOUNTAIN PROPERTIES LLC 0585EO-01-00-000H 0 COUNTY OF ALBEMARLE PARCEL AREA: 3.05 ACRES LIMITS OF DISTURBANCE: 2.73 ACRES ZONING: NEIGHBORHOOD MODEL DISTRICT (NMD) IN ACCORDANCE WITH ZMA2015-00001 OVERLAY DISTRICT: MANAGED STEEP SLOPES MAGISTERIAL DISTRICT: WHITE HALL SOURCE OF BOUNDARY AND TOPOGRAPHY: TIMMONS GROUP 28 IMPERIAL DRIVE STAUNTON, VA 24401 TELEPHONE: 540-885-0920 CONTACT:JOE MEDLEY JOE.MEDLEY@TIMMONS.COM SURVEY CONDUCTED: 2021 DATUM: HORIZONTAL: NAD83 (NA2011) VIRGINIA STATE GRID SOUTH VERTICAL: NAVD88 VIA GPS RTK OBSERVATIONS REQUIRED BUILDING SETBACKS (BLOCK 7 FRONT: 0 FT MINIMUM/25 FT MAXIMUM SIDE: 0 FT MINIMUM REAR: 0 FT MINIMUM MAXIMUM BUILDING HEIGHT: SINGLE FAMILY ATTACHED- 4.0 STORIES OR 60 FT SINGLE FAMILY DETACHED- 2.5 STORIES OR 42 FT EXISTING USE: VACANT RESIDENTIAL LAND PROPOSED USE: RESIDENTIAL DEVELOPMENT FOR TOWNHOUSE UNITS GROSS RESIDENTIAL DENSITY: 30 UNITS/3.05 ACRES = 9.83 DU/AC PROPOSED OPEN SPACE: 8.73% MAXIMUM IMPERVIOUS COVER: 1.78 ACRES WETLAND IMPACTS: NO WETLANDS ARE IMPACTED AS A PART OF THIS PROJECT UTILITIES: ACSA PUBLIC WATER AND SEWER PARKING REQUIRED: 2 SPACES PER SINGLE FAMILY ATTACHED (30 UNITS) 1.25 SPACES PER ACCESSORY (4 UNITS) 1 GUEST SPACE PER 4 SINGLE FAMILY ATTACHED (30 UNITS) 73 PARKING SPACES REQUIRED TOTAL PARKING PROVIDED: 2 GARAGE SPACES PER SINGLE FAMILY ATTACHED (30 UNITS) 2 DRIVEWAY SPACES PER SINGLE FAMILY ATTACHED (27 UNITS) 114 PARKING SPACES PROVIDED SPECIAL FLOOD HAZARD AREA INFORMATION: SPECIAL FLOOD HAZARD AREA (FLOODPLAIN) YES [ I NO [ X I SIDE: 1. THE STREAM BUFFER(S) HEREON SHALL BE MANAGED IN ACCORDANCE WITH THE ALBEMARLE COUNTY WATER PROTECTION ORDINANCE. 2. THE SITE IS NOT LOCATED WITHIN AN AGRICULTURAL -FORESTAL DISTRICT. 3. THE SITE IS LOCATED WITHIN THE SOUTH FORK RIVANNA RESERVOIR WATERSHED OF A PUBLIC WATER SUPPLY RESERVOIR. 4. ALL WATER AND SEWER FACILITIES ARE TO BE DEDICATED TO THE ALBEMARLE COUNTY SERVICE AUTHORITY. ROAD &UTILITY PLAN COUNTY OF ALBEMARLE, VIRGINIA SU6202100084 4/26/2021 game ® LAUREL F �$ '"CROZET Crozet Elementary0 �� CROSSING School "Al . RCHARD ACRES GRAYROCK�_ ; WAYLANDS GRANT a WAYLAND PARK jwrn a aoRd g' .fP BARGAMIN PARK `. e Crozet y*' • wm.n. ov qa Hyland Group® ."e�..4 R E A PARK qg VILL Claudius Crozeyarl 4 Crozet Park a..;,,r&Pool ig Family Vineyarill ...m. �° `°�P L" SITE 9R LOCATION pApK VIEW / ll ® Thdg ld TrailQ _ \ uw.w BROOK S° Old Treil Golf ClubOLD TRAIL ® r ��°' 1 HITE OAKS�.. P`e V A'W. _ I Sleb�°B The Summit MOUNTAIN Apartment Homes w,: 5 -- --" m o, HARVEST FARMS lb -dolt Q Crozet-Meadovr QPiedmontBaptist Church 16wewt` Brownsville 2" .. Exxon �<.Ras„GaPTumplke---- MO Feather&ssakQ • Photogra'dL�y Pro Re Nata Brews, B p O W N S V I L L E ff1 Willow Equlne� HEIGHTS O Western rAlbemarle QRAYeneey Lumber High SchoolO p Yancey Mills CONoratian j'� nunbyQ �..� s z.� 0 C7il hunch as FOREST GLEN EMERALD FOREST VICINITY MAP 111=10001 DEVELOPER: MARCH MOUNTAIN PROPERTIES LLC 1005 HEATHERCROFT CIRCLE SUITE 100 CROZET, VA 22932 CONTACT: DAVE BROCKMAN TELEPHONE: (702) 985-9088 EMAIL: DAVE@OLDTRAILVILLAGE.COM ENGINEER OF RECORD: TIMMONS GROUP 608 PRESTON AVE. SUITE 200 CHARLOTTESVILLE, VA 22903 CONTACT: CLINT SHIFFLETT, P.E. TELEPHONE: (434) 327-1690 EMAIL: CLINT. SHIFFLETT@TIMMONS.COM Sheet List Table Sheet Number Sheet Title CO.0 COVER C1.0 NOTES & DETAILS C1.1 NOTES & DETAILS C.1.2 NOTES & DETAILS C1.3 NOTES & DETAILS C2.0 EXISTING CONDITIONS & DEMOLTION C4.0 LAYOUT PLAN C4.1 LOT AND EASEMENT PLAN C5.0 UTILITY PLAN C6.0 GRADING & DRAINAGE PLAN C6.1 STORM INLET DRAINAGE MAP C7.0 STORM PROFILES C7.1 UTILITY PROFILES C8.0 ROAD PROFILES C9.1 STORMWATER CALCULATIONS L1.0 LANDSCAPE PLAN L2.0 LANDSCAPE DETAILS NUMBER OF SHEETS = 17 SIGNATURE PANEL: DEPARTMENT OF COMMUNITY DEVELOPMENT: PLANNING & ZONING ENGINEERING INSPECTIONS ARCHITECTURAL REVIEW BOARD DEPARTMENT OF FIRE AND RESCUE ALBEMARLE COUNTY SERVICE AUTHORITY VIRGINIA DEPARTMENT OF TRANSPORTATION HEALTH DEPARTMENT APPROVAL DATE CLINT W. ?: S FFLET >, Lic. N 14. ti 11/11/21 `�►�� ONAL M E O O U N ut N > E � W ~ U gu 3 Z cWc .0 m ti G W O Q j U m Z w - n O Z > a U z�ya U o H x U � U � _j � W L-1 U > O C c O O M v W J Uri 0 0 cD 0 0 0 V rV W > O O W o U Q W�-I Z O O DATE U) Cxf 0412612021 O DRAWN BY J. FOX } • DESIGNED BY • J. FOX • CHECKED BY C. SHIFFLETT • SCALE • N.A. i U 0 m a Z_ 1 � W' uL < W a�> J m 0 J a U �LL O J z Z U 1--1 O 0 0 DC J 0 IOB NO. 47652 SHEET NO. CO.0 L GENERALNOTES LEGEND 1. CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS FOR AS BUILT DOCUMENTATION, AS REQUIRED BY THE LOCALITY. THIS INCLUDES, BUT IS NOT LIMITED TO, TESTING, INSTALLATION DOCUMENTATION, SURVEY, ETC. ALL REQUIREMENTS SHALL BE DISCUSSED WITH THE LOCALITY PRIOR TO THE BEGINNING CONSTRUCTION. 2. ALL MATERIALS AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH CURRENT VIRGINIA DEPARTMENT OF TRANSPORTATION'S SPECIFICATIONS AND STANDARDS. 3. PRIOR TO ANY CONSTRUCTION, THE CONTRACTOR SHALL CONSULT THE ENGINEER AND VERIFY THE APPROVAL OF THE PLANS BY ALL FEDERAL, STATE AND LOCAL AGENCIES. 3. LAND USE PERMITS (LUP-A) MUST BE OBTAINED FROM THE VIRGINIA DEPARTMENT OF TRANSPORTATION PRIOR TO BEGINNING ANY CONSTRUCTION WITHIN THE EXISTING STATE MAINTAINED RIGHT OF WAY (INCLUDING ACCESS). 4. VDOT IS TO RECEIVE WRITTEN NOTIFICATION 48 HOURS PRIOR TO COMMENCING WITH INITIAL CONSTRUCTION ACTIVITIES. 5. THE CONTRACTOR SHALL VERIFY THE ELEVATIONS OF ALL POINTS OF CONNECTION OR PROPOSED WORK TO EXISTING CURBS, SANITARY LINES, WATERLINES, ETC, PRIOR TO CONSTRUCTION. 6. UPON DISCOVERY OF SOILS THAT ARE UNSUITABLE FOR FOUNDATIONS, SUBGRADES, OR OTHER ROADWAY CONSTRUCTION PURPOSES, THE CONTRACTOR SHALL IMMEDIATELY CONTACT THE OWNER. THESE AREAS SHALL BE EXCAVATED BELOW PLAN GRADE AS DIRECTED BY THE OWNER'S REPRESENTATIVE, BACKFILLED WITH SUITABLE MATERIAL AND COMPACTED IN ACCORDANCE WITH SPECIFICATIONS. 7. ALL STORM SEWER DESIGN AND CONSTRUCTION TO BE IN ACCORDANCE WITH VDOT STANDARDS. 8. ALL STORM SEWER PIPE SHALL BE REINFORCED TONGUE AND GROVE CONCRETE PIPE IN ACCORDANCE WITH ASTM-C-76. PIPE WITHIN THE RIGHT OF WAY SHALL BE MINIMUM CLASS III OR GREATER IN ACCORDANCE WITH CURRENT VDOT STANDARDS AND SPECIFICATIONS. 9. IF PRE -CAST UNITS ARE TO BE USED, VDOT SHALL BE NOTIFIED AND THE MANUFACTURER SHALL SUBMIT DRAWING DETAILS FOR REVIEW. CERTIFICATION AND VDOT STAMP WILL BE REQUIRED ON ALL UNITS. 10. ALL CONCRETE SHALL BE A3-AE (AIR ENTRAINED 3,000 PSI), UNLESS OTHERWISE NOTED. 11. ALL ENTRANCES ARE TO BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH CURRENT VDOT STANDARDS. 12. DESIGN CHANGES, SPECIFIED MATERIALS CHANGES AND/OR FIELD CHANGES FROM THE APPROVED PLANS NEED TO BE RESUBMITTED TO THE ENGINEER PRIOR TO PROCEEDING WITH THE WORK. A LETTER OF EXPLANATION SHALL ACCOMPANY THE REVISED PLANS AND/OR THE DRAINAGE CALCULATIONS, WHICH MUST BE SUBMITTED AND APPROVED BY THE ENGINEER. 13. CONTRACTOR SHALL VERIFY LOCATION AND ELEVATION OF ALL UNDERGROUND UTILITIES SHOWN ON PLANS IN AREAS OF CONSTRUCTION PRIOR TO STARTING WORK. CONTACT ENGINEER IMMEDIATELY IF LOCATION OR ELEVATION IS DIFFERENT FROM THAT SHOWN ON PLAN. IF THERE APPEARS TO BE A CONFLICT, AND/OR UPON DISCOVERY OF ANY UTILITY NOT SHOWN ON THIS PLAN, CALL MISS UTILITY OF CENTRAL VIRGINIA AT 1-800-552-7001. THE OWNER SHALL BE RESPONSIBLE FOR THE RELOCATION OF ANY UTILITY WITHIN EXISTING AND/OR PROPOSED RIGHT-OF-WAY REQUIRED BY THE DEVELOPMENT. 14. CASING SLEEVES SHALL BE PLACED AT ALL ROAD CROSSINGS FOR GAS, POWER, TELEPHONE AND CABLE TV SERVICE TRUNK LINES. (N/A) 15. THE INSTALLATION OF SEWER, WATER, AND GAS MAINS (INCLUDING SERVICE LATERALS AND SLEEVES) SHALL BE COMPLETED PRIOR TO THE PLACEMENT OF AGGREGATE BASE COURSE. 16. VDOT & ALBEMARLE COUNTY APPROVAL OF CONSTRUCTION PLANS DOES NOT PRECLUDE THE RIGHT TO REQUIRE ADDITIONAL FACILITIES AS DEEMED NECESSARY. 17. VDOT SHALL HAVE APPROVED THE AGGREGATE BASE COURSE(S) FOR DEPTH, TEMPLATE AND PERFORMED THE REQUIRED FIELD ACSA GENERAL WATER &SEWER CONDITIONS INSPECTION (PROOF ROLL) PRIOR TO PLACEMENT OF ANY SURFACE COURSE(S). CONTACT THE OWNER'S REPRESENTATIVE FOR INSPECTION FOR THE AGGREGATE BASE COURSE(S) 48 HOURS PRIOR TO APPLICATION OF THE SURFACE COURSE(S). SEPTEMBER 14, 2021 18. A PRIME COAT SEAL BETWEEN THE AGGREGATE BASE AND BITUMINOUS CONCRETE WILL BE REQUIRED AT THE RATE OF 0.30 GALLONS PER SQUARE YARD (REC-250 PRIME COAT) PER VDOT STANDARDS AND SPECIFICATIONS. 1. WORK SHALL BE SUBJECT TO INSPECTION BY ALBEMARLE COUNTY SERVICE AUTHORITY (ACSA) INSPECTORS. THE CONTRACTOR WILL 19. THE SCHEDULING OF AGGREGATE BASE INSTALLATION AND SUBSEQUENT PAVING ACTIVITIES SHALL ACCOMMODATE FORECAST BE RESPONSIBLE FOR NOTIFYING THE PROPER ACSA OFFICIALS AT THE START OF THE WORK. WEATHER CONDITIONS PER SECTION 315 OF THE ROAD AND BRIDGE SPECIFICATIONS. 2. THE ALBEMARLE COUNTY SERVICE AUTHORITY SHALL HAVE ACCESS TO USE THE AIRSPACE ABOVE THE LOCATIONS OF 20. THE OWNER'S REPRESENTATIVE SHALL HAVE APPROVED THE AGGREGATE BASE COURSE(S) FOR DEPTH, TEMPLATE AND PERFORMED CONSTRUCTION FOR THE FLIGHT OF UNMANNED AERIAL VEHICLES FOR THE PURPOSE OF IMAGERY COLLECTION. THE REQUIRED FIELD INSPECTION (PROOF ROLL) PRIOR TO PLACEMENT OF ANY SURFACE COURSE(S). CONTACT THE OWNER FOR 3. THE LOCATION OF EXISTING UTILITIES ACROSS THE LINE OF THE PROPOSED WORK ARE NOT NECESSARILY SHOWN ON THE PLANS AND INSPECTION FOR THE AGGREGATE BASE COURSE(S) 48 HOURS PRIOR TO APPLICATION OF THE SURFACE COURSE(S). WHERE SHOWN ARE ONLY APPROXIMATELY CORRECT. THE CONTRACTOR SHALL, ON HIS OWN INITIATIVE, LOCATE ALL UNDERGROUND 21. A GEOTECHNICAL ENGINEER IS TO ASCERTAIN CAUSE AND CERTIFY RECOMMENDED METHOD OF REPAIR FOR ALL PAVEMENT LINES AND STRUCTURES, AS NECESSARY. STRUCTURAL FAILURES PRIOR TO STATE ACCEPTANCE. (N/A) 4. ALL MATERIALS AND CONSTRUCTION SHALL COMPLY WITH THE CURRENT EDITION OF THE GENERAL WATER AND SEWER 22. ALL VEGETATION AND ORGANIC MATERIAL IS TO BE REMOVED FROM THE PROPOSED PAVEMENT LIMITS PRIOR TO CONDITIONING OF THE CONSTRUCTION SPECIFICATIONS, AS ADOPTED BY THE ACSA. SUBGRADE. 5. DATUM FOR ALL ELEVATIONS SHOWN IN NATIONAL GEODETIC SURVEY. 23. CERTIFICATION AND SOURCE OF MATERIALS ARE TO BE SUBMITTED TO THE OWNER'S REPRESENTATIVE FOR ALL MATERIALS AND BE IN 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING MISS UTILITY (1-800-552-7001). ACCORDANCE WITH THE ROAD AND BRIDGE SPECIFICATIONS, AND ROAD AND BRIDGE STANDARDS. 7. ALL WATER AND SEWER PIPES SHALL HAVE A MINIMUM OF THREE AND A HALF (3.5) FEET OF COVER MEASURED FROM THE TOP OF PIPE, 24. APPROVAL OF A DETAILED CONSTRUCTION SEQUENCING/MAINTENANCE OF TRAFFIC NARRATIVE FOR THE WORK ZONE IS A OVER THE CENTERLINE OF PIPE. THIS INCLUDES ALL FIRE HYDRANT LINES, SERVICE LATERALS AND WATER LINES, ETC. PREREQUISITE FOR ISSUANCE OF A LAND USE PERMIT ALLOWING ACCESS TO AND CONSTRUCTION WITHIN VDOT MAINTAINED RIGHT OF 8. ALL WATER AND SEWER APPURTENANCES ARE TO BE LOCATED OUTSIDE OF ROADSIDE DITCHES. WAY. (N/A) 9. VALVES ON DEAD END LINES SHALL BE RODDED TO PROVIDE ADEQUATE RESTRAINT FOR THE VALVE DURING A FUTURE EXTENSION OF 25. GRADE LINES ON PROFILES DENOTE FINISHED GRADE OF CENTER LINE THE LINE. OF ROAD. (N/A) 10. TREES ARE NOT PERMITTED IN THE ACSA EASEMENT. 26. ALL APPROACH GUTTERS TO SAG INLETS SHALL MAINTAIN A MINIMUM 11. THE CONTRACTOR SHALL BE RESPONSIBLE TO COMPLY WITH THE NO -LEAD REGULATION REGARDING BRASS FITTINGS EFFECTIVE SLOPE OF 0.004 ft./ft. JANUARY 4, 2014 (SENATE BILL 3874 WHICH AMENDS THE SAFE DRINKING WATER ACT). 27. WHERE A TYPE "B" NOSE IS SPECIFIED ON AN INLET IN CONJUNCTION WITH ROLL FACE CURB AND GUTTER OR CG-7, THERE SHALL BE A 12. THE SEWER LATERAL BEYOND THE CONNECTION AT THE SEWER MAIN SHALL BE PRIVATE. THE SEWER LATERAL STUB -OUT SHALL 20' TRANSITION ON EACH SIDE OF THE INLET. (N/A) UNDERGO THE ACSA LOW-PRESSURE AIR TEST TO SATISFY COUNTY TESTING REQUIREMENTS. VISUAL INSPECTION OF THE SEWER 28. CONTRACTOR SHALL PROVIDE A SEQUENCE OF CONSTRUCTION/MAINTENANCE OF TRAFFIC PLAN IN ACCORDANCE WITH THE LATERAL STUB -OUT SHALL BE WITNESSED BY THE COUNTY BUILDING INSPECTIONS DEPARTMENT. THIS INSPECTION SHALL OCCUR STANDARDS AND GUIDELINES CONTAINED IN THE 2011 EDITION OF THE VIRGINIA WORK AREA PROTECTION MANUAL FOR REVIEW BY THE UNDER AN "OTHER PLUMBING" PERMIT WHICH MUST BE OBTAINED BY THE CONTRACTOR. ENGINEER, OWNER'S REPRESENTATIVE, AND VDOT PRIOR TO STARTING WORK THAT IMPACTS TRAFFIC ON STATE ROADS. 13. THE SEWER LATERAL BEYOND THE CONNECTION AT A MANHOLE SHALL BE PRIVATE. VISUAL INSPECTION AND PRESSURE TESTING OF 29. ALL NEW HANDICAP ACCESSIBLE REQUIREMENTS ON -SITE AND WITHIN ALL NEW STRUCTURES SHALL COMPLY WITH THE 2015 UNIFORM THE SEWER LATERAL SHALL BE WITNESSED BY THE COUNTY BUILDING INSPECTIONS DEPARTMENT. THIS INSPECTION SHALL OCCUR STATEWIDE BUILDING CODE, 2015 VIRGINIA CONSTRUCTION CODE, AND ICC/ANSI Al17.1-03. UNDER AN "OTHER PLUMBING" PERMIT WHICH MUST BE OBTAINED BY THE CONTRACTOR. 30. THE CLEAR ZONE IS TO BE FREE OF STORED MATERIALS AND PARKED EQUIPMENT. 14. THE FIRE SPRINKLER MAIN DOWNSTREAM OF THE GATE VALVE IS PRIVATE. VISUAL INSPECTION AND TESTING OF THE FIRE SPRINKLER 31. HORIZONTAL AND VERTICAL SIGHT DISTANCES SHALL BE FREE OF PARKED VEHICLES. MAIN DOWNSTREAM OF THE GATE VALVE SHALL BE WITNESSED BY THE COUNTY BUILDING INSPECTIONS DEPARTMENT. THIS 32. ALL EXCAVATED AREAS WITHIN THE CLEAR ZONE THAT HAVE A DEPTH GREATER THAN 6" SHALL HAVE A 6:1 STONE WEDGE PLACED AT INSPECTION SHALL OCCUR UNDER AN "OTHER PLUMBING" PERMIT WHICH MUST BE OBTAINED BY THE CONTRACTOR. THE END OF THE DAY 15. ALL FLUSHING OF FIRE SPRINKLER MAINS SHALL NOT OCCUR UNTIL APPROVAL IS GIVEN BY THE ACSA. 33. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. 16. PRIOR TO BACKFLOW PREVENTION DEVICE TESTING AND THE ESTABLISHMENT OF WATER SERVICE, ALL BACKFLOW PREVENTION 34. ALL WATER LINES, SEWER LINES, AND FIRE LINES FROM THE MAIN TO THE STRUCTURE MUST HAVE A VISUAL INSPECTION PERFORMED DEVICE INSTALLATIONS SHALL MEET THE ACSA BACKFLOW REQUIREMENTS AS DETAILED IN SECTION 8 OF THE MOST RECENT BY THE BUILDING DEPARTMENT. SEWER AND FIRE LINES IDENTIFIED BUT NOT WATER LINES. REVISION OF THE ACSA RULES AND REGULATIONS. 17. A DEED OF EASEMENT AND EASEMENT PLAT FOR THE UTILITY EASEMENTS, APPROVED BY THE ACSA, SHALL BE RECORDED PRIOR TO ANY WATER AND/OR SEWER SERVICE BEING ESTABLISHED. Albemarle County As -built Road Plan Policy As -built drawings shall be prepared for all public and private roadway construction projects within Albemarle County. The following is a list of the minimum information required on the drawings. Additional information may be requested. The Coun only reviews private road as -built plans. The coup does not review or YCounty Y P P county approve public road as-builts. For questions regarding public roads, please consult with VDOT. 1. A signed and dated professional seal of the preparing engineer or surveyor. 2. The name and address of the firm and individual preparing the drawings on the title sheet. 3. "As -built" must be labeled on the drawings with the date of preparation or revision. 4. The constructed location of all items associated with the road construction must be shown. The items include, but are not limited to the following: a. Horizontal Alignment - Show and label measurement points, and an interpreted line between g P r'P measurements. Show the as -built centerline over the designcenterline. Distinguish between the design gu elevation and as -built by labels and line type. Measurements shall be at each station as a minimum, and at frequent enough intervals to accurately portray the as -built centerline, and the position of the roadway within the right-of-way or easement. An portions outside the right-of-way or easement must be gh Y Y P corrected b plat or construction. Y b. Vertical Alignment - Show and label measurement points, and an interpreted line between measurements. Show the as -built centerline over the design centerline. Distinguish between them by labels and line type. Write the constructed vertical elevations adjacent to the design elevations. Distinguish between the elevations by striking a single line through the design elevation. Measurements shall be at each station as a minimum and frequent enough intervals to accurately portray the as -built . q Sh Y P Y centerline. For alignments which deviate significantly from the design, provide curvature and sight - distances. Corrections may be required for alterations from the design alignment. b. Edge of Pavement - Display the constructed edges of pavement and width measurements at every station, or more frequently if necessary to accurately portray the as -built edges. Show the as -built edges over the design edges. Show and label constructed edge of pavement radii for all intersections and cul- de-sacs. Edges for sidewalk, as well as ramps and curb cuts must be included. c. Culverts, Pipes and Drainage Structures - Display the installed type of drainage structure, culvert/pipe size, material, inlets or end treatment(s), inlet and outlet protection, alignment and invert elevations compared to design. For slopes flatter than design, or inverts shallower than design, provide computations verifying design standards. d. Ditch Lines - Display the constructed location of all ditch lines, including typical section, direction of flow, and linings. c. Drainage Easements - Show all platted easements with dead book references labeled. Drainage must be within platted right-of-way or drainage easements. Provide copies of recorded documents. e. Guardrail - Display the constructed location of guardrail, including the guardrail type, length and applied end treatments, compared to design. f. Right of way and associated easements - Label deed book and page numbers for all dedicated right- of-ways, sight easements, slope easements, etc., and provide copies of recorded documents. g. Pavement Designs - Label the as -built pavement and base on the design typical sections. Strike through any design elements which were not applied. Inspection reports are required for fill compaction, CBR's, and pavement applications. h. Street Trees - if street trees are on the design plan, provide design and as -built locations and species. i. Signs - Show all installed signs and pavement markings. Include any pedestals or other features. Albemarle County Public Road Acceptance Procedure The processing, inspection and acceptance of public roads is administered solely by VDOT. The County is not involved in this process until the road is ready for acceptance. County bond releases (or partial releases) will be considered on public roads for all portions approved by VDOT. The following items are required to be submitted for bond releases to be considered: 1. Bond Inspection Request and fee A form and fee are required for each bond, such as for a project with multiple phases and bonds. 2. As -built plan approved by VDOT, and copies of all recorded drainage easements, sight easements, and right-of-way plats. Plats should be copies of the actual recorded documents from the Clerk's office. An as -built plan prepared in accordance with the County's As -Built Road Plan Policy is required. VDOT does not always follow this paperwork or policy, but for bond releases, especially where VDOT has not yet accepted the road, the minimum requirements of this policy must be met, if only to ensure that all improvements are in right-of- way and easements. 3. Written documentation of acceptance from VDOT for the entire roadway or for completed items. eP Y P Formally, this is sent directly to the county on an AM-4.3 from VDOT, when VDOT requests that the Board of Supervisors pass a resolution of acceptance. After the resolution of acceptance is sent to VDOT, it is usually about six weeks before actual acceptance takes place, and VDOT issues a formal memo to the county with the road additions and new route numbers. This final notification is needed for bond release. For partial bond releases prior to this some comes ondence from VDOT for items inspected and approved is necessary. This is usually in the form P P PPro scary Y of letters approving compaction reports, CBR's, pavement cores, pipe video, or other items where partial release is sought. A final punchlist inspection report from VDOT can be used for a partial bond release, but only if outstanding items are not too broad. If the punchlist is not official, and only a courtesy review, it carries much less weight. In any case, if there are problems meeting the eligibility or occupancy minimums, and it is not known how long improvements may sit, or need replacement, partial releases may not be possible. 4. Signed and sealed letter from a professional engineer listing and certifying that completed improvements are built according to plan. Please do not e-mail or fax copies of this letter. An original signature and certifying seal are required. Please do not use qualifying statements such as "it appeared", or "to the best of my knowledge", or "generally in accord". Improvements were either built to plan, or they were not. As -built measurements, construction inspections, and other field verifications should be cited and included. Tolerances should be noted. The items not built according to plan must be listed, with explanations. Deviation in pavement materials and thicknesses must be listed. If street trees or sidewalks, or other items were moved, or added, this should be noted. If drainage changed, by addition or deletion of culverts, inlets, or re -alignments of pipes or grades, this should be verified by revised computations and attached to the letter. If there are outstanding items or omissions, these should be listed. Graphics are helpful. In short, please provide more than a statement of opinion or assurance. Please demonstrate that the improvements and construction have been inspected, investigated and documented, and me certified in detail, and county staff will not be in the position of discovering discrepancies and deficiencies in the field. 5. Certificate of Completion This form must be received for release of a bond. It is available on the county website. In the case of reductions, a letter listing the outstanding items that need to be completed before signing the certification is acceptable. It must be signed by the owner. This form says all subdivision improvements have been completed. It also says that all construction conforms to approved plans and any discrepancies have been approved by the County. This means the as -built plans have been approved by VDOT, and they have agreed to any discrepancies, which should be documented in acceptance correspondence or punchhsts. 1 Nov 2011 35. RETAINING WALLS GREATER THAN TIN HEIGHT REQUIRE A SEPARATE BUILDING PERMIT. WALLS EXCEEDING 4' IN HEIGHT REQUIRE A STAMPED ENGINEERED DESIGN ALSO. WALLS REQUIRE INSPECTIONS AS OUTLINED IN THE USBC. 36. ALL ROOF DRAINS SHALL DISCHARGE IN A MANNER NOT TO CAUSE A PUBLIC NUISANCE AND NOT OVER SIDEWALKS. 37. BUILDINGS OR STRUCTURES BUILT BEFORE JANUARY 1, 1985 MUST HAVE AN ASBESTOS SURVEY PERFORMED IN ORDER TO APPLY FOR A DEMOLITION PERMIT. ASBESTOS REMOVAL PERMITS ARE REQUIRED IF POSITIVE FOR SUCH FROM ALBEMARLE COUNTY AND VDOLI. CONTACT VDOLI FOR THEIR ADDITIONAL REQUIREMENTS AND PERMITS FOR DEMOLITION PROJECTS AT (540)562-3580 (EXT. 131). BLASTING NOTES 1. BLASTING SHALL NOT BE PERMITTED ON THIS PROJECT. ALBEMARLE COUNTY STORMWATER MANAGEMENT NOTES 1. ALL DAMS AND CONSTRUCTED FILL TO BE WITHIN 95% OF MAXIMUM DRY DENSITY AND 2% OF OPTIMUM MOISTURE CONTENT. ALL FILL MATERIAL TO BE APPROVED BY A GEOTECHNICAL ENGINEER. A GEOTECHNICAL ENGINEER IS TO BE PRESENT DURING CONSTRUCTION OF DAMS. 2. PIPE AND RISER JOINTS ARE TO BE WATERTIGHT WITHIN STORMWATER MANAGEMENT FACILITIES. 3. FOR TEMPORARY SEDIMENT TRAPS OR BASINS WHICH ARE TO BE CONVERTED TO PERMANENT STORMWATER MANAGEMENT FACILITIES; CONVERSION IS NOT TO TAKE PLACE UNTIL THE SITE IS STABILIZED, AND PERMISSION HAS BEEN OBTAINED FROM THE COUNTY EROSION CONTROL INSPECTOR. Albemarle County Engineering Final Plan General Notes Page I of 4 ALBEMARLE COUNTY FINAL PLAN GENERAL NOTES General Construction Notes 1. Prior to any construction within any existing public right-of-way, including connection to any existing road, a permit shall be obtained from the Virginia Department of Transportation (VDOT). This plan as drawn may not accurately reflect the requirements of the permit. Where any discrepancies occur the requirements of the permit shall govern. 2. All materials and construction methods shall conform to current specifications and standards of VDOT unless otherwise noted. 3. Erosion and siltation control measures shall be provided in accordance with the approved erosion control plan and shall be installed prior to any clearing, grading or other construction. 4. All slopes and disturbed areas are to be fertilized, seeded and mulched. 5. The maximum allowable slope is 2:1 (horizontal:vertical). Where reasonably obtainable, lesser slopes of 3:1 or better are to be achieved. 6. Paved, rip -rap or stabilization mat lined ditch may be required when in the opinion of the County Engineer, or designee, it is deemed necessary in order to stabilize a drainage channel. 7. All traffic control signs shall conform with the Virginia Manual for Uniform Traffic Control Devices. 8. Unless otherwise noted all concrete pipe shall be reinforced concrete pipe - Class II1. 9. All excavation for underground pipe installation must comply with OSHA Standards for the Construction Industry (29 CFR Part 1926). NOTES: 1. SPLASH BLOCK SHALL BE CONCRETE, PLASTIC, OR SIMILAR MATERIAL. 2. SPLASH BLOCK SHOULD BE SLOPED AWAY FROM DISCHARGE POINT. 3. SPLASH BLOCK SHOULD DISCHARGE SHEET FLOW INTO A VEGETATED OR STABILIZED FLOW PATH DIRECTLY DOWNSTREAM. SPLASH BLOCK, STABILIZED FLOW PA DOWNSPOUT & SPLASH BLOCK DETAIL No Scale Albemarle County Private Road Acceptance Procedure This is the procedure developed by the Albemarle County Community Development Department for the completion of private roads. The items in this list must be completed in the order given. 1. Tests and Inspections: Have all necessary tests and inspections performed by a professional engineer or eotech or VDOT certified inspector. This should include at a minimum g Pce , a. California Bearing Ratio (CBR) tests, b. stone depth inspections, including installation of under -drains and cross -drains, c. fill compaction tests, d. pipe and drainage structure video inspections or equivalent, e. base and surface pavement inspections, documenting materials, thickness and compaction f. concrete tests g. structural and related inspections for any bridges and foundations Compile a report of these tests, certified by a professional engineer, and submit this report with the as -built plans. 2. As -built plans and plats: Provide drawings of the constructed improvements according to the Albemarle CountyAs-built Road Plan Policy. Provide copies of all recorded drainage easements Y P g easements sight right-of-way Plats should be copies of the actual recorded documents g and plats. from the Clerk's office. Before completing as -built drawings, make any corrections necessary to ensure all improvements are within right-of-ways and easements. 3. Bond inspection: Request a bond reduction or release inspection from the County, which will reduce or release your bond, indicating completion or partial completion, or generate a letter indicating items in need of documentation or completion. The following documents will be needed with your bond inspection request; A. Completed Bond Inspection Request form and fee A form and fee are required for each bond, such as for a project with multiple phases and bonds. B. As -built documents per items 1 and 2 above. An as -built plan prepared in accordance with the County's As -Built Road Plan Policy is required. For any releases or reductions, the minimum requirements of this policy must be met, if only to ensure that all improvements are in right-of-way and easements. C. Signed and sealed letter from a professional engineer listed and certifying that completed improvements are built according to plan. Please do not e-mail or fax copies of this letter. An original signature and certifying seal are required. Please do not use qualifying statements such as "it appeared", or "to the best of my knowledge", or "generally in accord". Improvements were either built to plan, or they were not. As -built measurements, construction inspections, and other field verifications should be cited and included. Tolerances should be noted. The items not built according to plan must be listed, with explanations. Deviation in pavement materials and thicknesses must be listed. If street trees or sidewalks, or other items were moved, or added, this should be noted. If drainage changed, by addition or deletion of culverts, inlets, or re -alignments of pipes or grades, this should be verified by revised computations and attached to the letter. If there are outstanding items or omissions, these should be listed. Graphics are helpful. In short, please provide more than a statement of opinion or assurance. Please demonstrate that the improvements and construction have been inspected, investigated and documented, and are certified in detail, and county staff will not be in the position of discovering discrepancies and deficiencies in the field. D. Completed Certificate of Completion This form must be received for release of a bond. It is available on the county website. In the case of reductions, a letter listing the outstanding items that need to be completed before signing the certification is acceptable. It must be signed by the owner. This form says all subdivision improvements have been completed. It also says that all construction conforms to approved plans and any discrepancies have been approved by the County. STD. GUTTER WITH BOOT COUNTY OF ALBEMARLE STMMD� Department of Community Development Construction Record Drawings (As -built) for VSMP The followingis a list of information required on construction record drawings for � g stonnwater facilities reference Water Protection Ordinance 17-422 . It is preferable erable that the � ) .f construction record drawing be prepared by someone other than the designer. Please do not provide design drawings as construction record drawings. A. A signed and dated professional seal of the preparing engineer or surveyor. B. The name and address of the firm and individual preparing the drawings on the title sheet. C. The constructed location of all items associated with each facility, and the inspection records to verify proper dimensions, materials and installation. The items include, but are not limited to the following: 1. Inspection Records and photographs for pipe trenches and bedding, including underdrains. 2. Video Pipe Inspection for any pipes which are not accessible or viewable. 3. Updated Location with geo-coordinates of all facilities. 4. Verified Drainage Area maps for the drainage area treated and for drainage to the facilities. g P g g 5. Current physical and topographic survey for all earthen structures. Ponds should include a survey of the pond bottom. Surveys should verify pond volumes are per design. Corrections may be required for alterations from the design. 6. Plants, location and type. 7. Plans and profiles for all culverts, Pipes, Risers, Weirs and Drainage Structures - Display the installed type of drainage structures, culvert/pipe size, weirs, materials, inlets or end treatment(s), inlet and outlet protection, alignment and invert elevations compared to design. 8. Computations: For significant deviations from design, provide sealed computations verifying that the as -built condition is equivalent or better than design. 9. Ditch Lines - Display the constructed location of all ditch lines and channels, including typical sections and linings. 10. Easements - Show all platted easements with dead book references labeled. Facilities and drainage must be within platted easements. Provide copies of recorded documents. 11. Guardrail, fences or other safety provisions - Display the constructed location of all safety provisions; fences, guardrail, including the type, length and applied end treatments, compared to design. 12. Material layers - biofilter media, stone layers, sand layers, keyways and cores must be verified as to material types and depths. Include inspection reports, boring or test pit reports and materials certifications. Biofilter media must be an approved state mix. 13. Access roads - show location of access roads, surface treatment, drainage, etc, as applicable. 14. Compaction reports are required to verify fill compaction in dams. 15. Manufacturers certifications for proprietary BMP's certifying proper installation and functioning. 11211111111911010 CLINT W. !: S FFLET a� • Lit. NerS4380 ��4',* I/II/21 K•� uati'btAL ,na M E 0 o N � N C > E w a E H_ w w 3 LL o 3 p LL 0 wO `mom 0 W L M Qom_ Voo J - M t7W NV w IT 30'x LL � Q v _ N N F a . c O' Y ON N W M a� o w N Z 0 ti W Z W OU CIL U � O � U LU Z OU O U a a 02 wV) j W W F 0 DATE 0412612021 DRAWN BY J. FOX DESIGNED BY J. FOX CHECKED BY C. SHIFFLETT SCALE N.A. U U 0 MJ W Q z co l (D J > W Q w LLJ J Q w J co °6 J Q W ~ O F" 0 J z Z O U L.L 0 J 0 JOB NO. 47652 SHEET NO. C1.0 1 Nov 2011 L SIGNAGE NOTES: a ■ ■ 1. ALL SIGNING AND PAVEMENT MARKING SHALL BE IN ACCORDANCE WITH THE MOST CURRENT EDITION OF EACH OF THE FOLLOWING AND ANY REVISION THERE TO: A. MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES. B. THE VIRGINIA SUPPLEMENT TO THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES. C. THE VIRGINIA DEPARTMENT OF TRANSPORTATION ROAD AND BRIDGE SPECIFICATIONS. D. THE 2000 INTERNATIONAL FIRE CODE. 2. SIGN LOCATIONS ARE APPROXIMATE AND ARE TO BE MODIFIED IN THE FIELD TO AVOID CONFLICT WITH UNDERGROUND UTILITIES OR OTHER CONSTRUCTIONS, AND TO COMPLY WITH STANDARDS REFERENCED IN NOTE 1 ABOVE. 3. ALL SIGNS AND PAVEMENT MARKINGS ARE TO BE FURNISHED AND INSTALLED BY THE CONTRACTOR. ALL SIGNS TO BE FURNISHED AND INSTALLED WITH STANDARD U POST GALVANIZED BY THE CONTRACTOR. SOLID WHITE LINE 24" S T 0 P (TYP.) 12 STD. (VARIES) R1-1 NOTE: STOP SIGNS TO BE 30" WITH STOP BAR DETAIL HIGH INTENSITY SHEETING NO SCALE SOLID WHITE LINE 6' 2 I 2 (TYP.) (TYP.) STRIPING AND SIGNAGE DETAIL NON -SLIP BROOM FINISH VARIABLE WIDTH' MAX. CROSS SLOPE 2% 1 A. A I " 4" 3,000 PSI AIR -ENTRAINED CONCRETE COMPACTED SUBGRADE 4" TYPE 21A STONE COVER DENOTES CONCRETE SIDEWALK PAVEMENT ON PLANS NOTE: SIDEWALKS SHALL BE CONSTRUCTED IN ACCORDANCE WITH VDOT STANDARDS. 1.5" ASPHALTIC CONCRETE SURFACE COURSE - SM-9.5A 2" INTERMEDIATE BASE COURSE - IM19.OA 3" INTERMEDIATE BASE COURSE - BM25.OA 8" TYPE 21-B AGGREGATE SUBBASE COURSE \/\,%i�\/i�\%\\\%\\\/\�%i�\/ \\ f� COMPACTED SUBGRADE (PER GEOTECHNICAL REPORT) DENOTES HEAVY DUTY ASPHALT PAVEMENT ON PLANS HEAVY DUTY ASPHALT PAVEMENT SECTION No Scale 2" BITUMINOUS CONCRETE SURFACE COURSE - SM-9.5A VARIABLE WIDTH' (PLACED IN ONE LIFTS) NON -SLIP BROOM FINISH MAX. CROSS SLOPE 2% 8" TYPE 21 B AGGREGATE BASE COURSE r DENOTES LIGHT DUTY ASPHALT PAVEMENT ON PLANS 4" 3,000 PSI AIR -ENTRAINED CONCRETE COMPACTED SUBGRADE 4" TYPE 21 B STONE LIGHT DUTY ASPHALT PAVEMENT SECTION NOTE: SIDEWALKS SHALL BE CONSTRUCTED IN No Scale ACCORDANCE WITH VDOT STANDARDS. m' R= X 1 CONTROL JOINT SPACED AT WIDTH OF WALK (MAXIMUM) CONCRETE SIDEWALK PAVEMENT SECTION C .. i .. ..e .�1' MITE-�.: �.:,'�. i'��, •j° , JX�; . a ,. :.. •: EXPANSION JOINT AT MAX No Scale OF 30', WITH PREMOLDED EXPANSION FILLER EXISTING PAVEMENT PROPOSED PAVEMENT 2 a SAWCUT THROUGH rL MATCH EX. CROSS NOTE: PROPOSED J FJ(, SURFACE W PAVEMENT MUST TIE U SLOPE UNLESS OTHERWISE IN WITH EXISTING COURSE x LU & REMOVE W SPECIFIED ON PLANS PAVEMENT PAVEMENT 2' MIN. PROPOSED SURFACE 2"+ COURSE EXISTING PAVEMENT MILL EX. SURFACE COURSE BASE COURSE SAWCUT EX. EDGE OF PAVEMENT AGGR. COURSE PAVEMENT REPLACEMENT JOINT DETAIL No Scale NORMAL CONIC WALK .. .. .�. , y .. A'.0' . . . ° .. � COMPACTED SUBGRADE CONCRETE SIDEWALK JOINT DETAIL No Scale PM 4" 21-B STONE CONIC CURB AND GUTTER CLASS 3A, (Pc=3,000 PSI) CONCRETE CG-9B d 1NA' CENTRMICE WIDTH OF \ d n � z_ 13 LIMITS OF PED. LIMITS OF PED. ACCESS ROUTE ® p NON -TRAVERSABLE -' ACCESS ROUTE / n n a WIDTH OF ENTRANCE UNPAVED SPACE UNPAVED SPACE COMPACTED n �,, a. . EXISTING OR PROPOSED EXPANSION JOINT SUBGRADE b' SIDEWALK OR SIDEWALK SPACE o a � ENTRANCE d a ' F \/ aA d dd 2 0 V XE : Z EXPANSION JOINT LIMITS OF PED. CCESS ROUTE ® o NON -TRAVERSABLE = LIMITS OF PED. ACCESS ROUTE r 502 E� �E w 4" MIN. Mil w vTi U 1 �. CURB INCLUDED IN PEDESTRIAN ACCESS ROUTE DETAIL WITH & 9 ENTRANCE GUTTER rc WITHOUT UNPAVED SPACE w 6" 6112 _D Q w ADDITIONS RIGHT-OF-WAY 5 REG�UIRED IF THE LIMITS 2 -0" J OF PEDESTRIPN ACCESS ROUTE HK7 EXTEND BEYOND I.-' 0 I/' FLOW LINE i EXISTING OR PROPOSED VDOT R T-OF WAY. VDOT STANDARD CG-6 CURB & GUTTER EXPANSION JOINT ENTRANCE WDTH • ' - NO Scale DESIRABLE MINIMUM 16' • b: ABSOLUTE MINIMUM IT ® PEDESTRIAN ACCESS ROUTES PROVIDE A CONTINUOUS UNOBSTRUCTED, STABLE, FIRM AND SLIP RESISTANT oo ooeo, e, PATH CONNECTING ALL ACCESSIBLE ELEMENTS OF A . 0.o4oe a Face of Curb Invert Line FACILITY THAT CAN BE APPROACHED. ENTERED AND EDGE OF PAVEMENT USED BY PEDESTRIANS. IF ACCESS ROUTE IS ADJACENT TO BACK OF CURB, MINIMUM WIDTH SHOULD BE 6'. SECTION F-F HALF PLAN CIF PEDESTRIAN ACCESS ROUTES f#1 ARE BEING 2'-0" [:6: 21c 11 IS REOU REED MWITH INIMUM MAX. 2Z CROSS SLOPE. WIDTH 4' TRERSLE R-/�A t✓I -� e. 117 WHEN USED IN CONJUNCTION WITH STANDARD • ' D. - D. - D. - D. - D. PARABOLIC CG-3 OR CG-7, THE CURB FACE ON THIS �' �• • D' " A ' A A - UZJ SIDE_ W,Y� CURVE STANDARD IS TO RE ADJUSTED TO MATCH THE oo oo,o o.o - SN'A(%L I SPACE MOUNTABLE CURB CONFIGURATgN. oo`Z o: o ® ® ®----------- xX SECTION E-E q�r/�pOply�IyorO°q'a.•ro rAC!iiaw, SOPS, N x X y) /rx•A61 )5 m0/MOInM. N. 'D• N' '. e.e o•_ C'0X TO 10X CHANGE ;�_3•• M 1OeddM mvm A 49-bop e:Ze PeH b4 b4 CLASS A3 (H.E.S.) CONC. 2" =e4'�o44o. e.e 6" AGGR. BASE TYPE I SIZE 21B- 5'-0" 12% MAX. SLOPE 5'-0" ® POINT OF GRADE CHANGE t.'�• p, )R CURB AND GUTTER ONLY yl .� -e : p FIGURE 5-CURB AND GUTTER DETAILS" FOR SIDEWALK CURB AND GUTTER x x 12 % MAXIMUM INCREASE IN SLOPE AT MINIMUM 10- INTERVALS oo be . o . qoo The following notes apply to CG-6, CG-7 and Rolltop curb: BUILT CONCURRENTLY SECTION L C x x x 8 %% MAXIMUM DECREMUM ASE FOR E IN SLOUCCE PE R FIRST 106ILIM N°ENTERVARVAL D e.ee a 1. Curb and gutter may be precast of Class A4 hydraulic cement concrete or cast in SECTION D-D place using Class A3 hydraulic cement concrete. STANDARD ENTRANCE GUTTER XVIDoT ROAD AND BRIDGE STANDARDS 2. When used with stabilized, open -graded drainage layers, the bottom of the curb REVISION DATE 1 SHEET 1 OF 1 and gutter shall be constructed parallel to the slope of the sub -base courses and VIRGINIA DEPARTMENT OF TRANSPORTATION 07/15 to the depth of the pavement but not less than the thickness shown. 1 711 - CONTINUE 21 B STONE BASE FROM ADJACENT PAVEMENT SECTION UNDER CURB 11 m NOTES THIS WI MANHOLE AND MET INVERTS N ATURES SN,E WITH TN6 LASS OR IS ER APPLY TO O THOSE STRUCTURES INVERT OF SPECIFIED ON PLANS OR WHERE INVERT OF PIPE IS ABOVE AVERT Qi STRUCTURE. I1: -SUIPE TO DRAW To INVERT OF OUTLET PPE SECTION A -A METHOD OF TREATMENT IN DROP INLETS SLOPE TO DRAIN TO Man" OF OUTLET PPE ADANCEIT TRAVEL LANE MPHALT PAVEMENT WIDENING X EDGE OF EXISING PAVEMENT AS DETERMINED IN FELD) TACK COAT THE PROPOSED CONSTRUCTION JOINT EXISTING ASPHALT LAYERS PROPOSED ABPHALT LAYERS ----_--- EXISTING SUBBASE PROPOSED SIRBASE ------ COMPACTED SUBGRADE CONSTRUCTION JOINT DETAIL ® REMOVE EXISTING ASPHALT LAYERS TO EXISTING SUBBASE AND REPLACE WITH PROPOSED ASPHALT MOONING LAYERS ® PROPOSED MNMUM IV, NCH THICK ASPHALT SURFACE COURSE (SEE NOTE 5) s MINIMUM 12 INCHES. OR GREATER AS NECESSARY TO ABUT TIE FULL THICKNESS OF EXISTING ASPHALT LAYERS AS DETERMINED BY CORES ISEE NOTE 3) NOTES) 1. ASPHALT PAVEMENT WIDENNG SHALL HAVE A PAVEMENT DESIGN IN ACCORDANCE WITH CURRENT VDOT PROCEDURES NU BE APPROVED BY THE ENGBEEN. I. THE PAVEMENT DESIGN FOR ASPHALT PAVEMENT WIDENING SHALL MEET OR EXCEED THE DEPTHS AND TYPES OF THE LAYERS OF EXISTING PAVEMENT. SUBSURFACE MANAGE OF THE EXISTING NO PROPOSED PAVEMENT SHALL BE ADDRESSED IN THE PAVEMENT DESIGN, 3. A MINIMUM OF THREE CORES WALL BE TMEN ALONG THE CENTER OF THE ADJACENT TRAVEL LANE TO DETERMINE THE TYPE AND THICKNESS OF EXISTING PAVEMENT LAYERS. THESE CORES SHALL BE SPACED NO MORE THAN 500 FEET APMT. {. THE ADJACENT TRAVEL LACE SHALL BE MLLED A MINIMUM DEPTH OF 1 Vt PITH INCHES AND READED WITH AN ASPHALT SURFACE COURSE TO MATCH E PROPOSED PAVEMENT WIDENING SURFACE COURSE, UNLESS WAVED BY LIRE ENGINEER. 5. THE ENGINEER MAY REWIRE THE LIMING DEPTH OF THE EXISTING PAVEMENT TO BE ADJUSTED TO ACHIEVE AN ACCEPTABLE PAVEMENT CROSS -SLOPE AND EFFECTVE SURFACE DIWNAGE. G. EXISTING PAVEMENT MMKINGS AND MAKERS WITHIN THE PROJECT LIMITS SHALL BE RESTORED SUBJECT TO THE APPROVAL OF THE ENGINEER. 7. FINAL TRANSVERSE PAVEMENT TEAK SHALL CONFORM TO THE REQUIREMENTS OF SECTION 315.05(c) OF THE SPECIFICATIONS EXCEPT THAT ALL JOINTS AT TEHN LOCATIONS SHAL BE TESTED LEND A 1D FOOT STRAIGHTEDGE IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION 315.07(N OF WE DETAILS OF NSHARING ING A5 SHOWN HEWON IMF FOR EXAMPLE I I PUP09ES ONLY. EACH MANHOLE OR CROP IN S TO BE SHRED C MIVWAILY T° BEST FIT THE PARTICULAR LLET ML OUTLET THr CONITGURATION AND FLOW LINES. SECTION B-B SPESPECIFICATIONS. PLAN! METHOD OF TREATMENT IN MANHOLES -%VOOT ROAD AND BRIDGE STANDARDSSTANDARD METHOD OF SHAPING MANHOLE & INLET INVERTS VIRGINIA CEPMT.EM OF TRNSPCBTATDN SD" GATDN REND C/�T ASPHALT PAVEMENT WIDENING FOR WIDENING SUBJECT TO TRAFFIC VIRGINIA DEPARTMENT OF TRANSPORTATION SIGN AND POST DETAIL SHEET 1 of 1 REVISION DATE 302 ROD ANO BRIocESTANOARDs SHEET 1 of 1 REVISION DATE No Scale IOfi.OS 2018 ROAD &BRIDGE STANDARDS FENNEL ROAD CROSS SECTION VDOT FLEXIBLE PAVEMENT DESIGN (NEW SUBDIVISION STREETS) COUNTY ALBEMARLE SUBDIVISION OLD TRAIL VILLAGE BLOCK 7C STREET NAME FENNEL & ORION EXT. DESIGN ENGINEER TIMMONSGROUP- 1LF 1.5" SM-9.5A CERTIFYING ENGINEER N/A ROLL-TOP CIL ROLL-TOP 2' 1 f (PAVEMENT WIDTH) / �{ [3 0, I \ I 3 0 2% 2% --� 77COMPACTED SUBGRADE `2" BM25.0 6" 21 A NOTE: ROAD CROSS SECTION COMPLIES WITH ALBEMARLE COUNTY DESIGN STANDARDS. FENNEL ROAD CROSS SECTION (PRIVATE RIGHT -OF -WA No Scale ORION EXT. CROSS SECTION CG-6 C%L CG 6 26' 2.51 (PAVEMENT WIDTH) , 2% 1 2% y [25 I- 1 COMPACTED SUBGRADE I 5' 6' I` SIDEWALK (PLANTING STRIP) NOTE: ROAD CROSS SECTION COMPLIES WITH ALBEMARLE COUNTY DESIGN STANDARDS. ORION EXTENDED CROSS SECTION (PUBLIC RIGHT -OF -WA No Scale SIDEWALK (WHERE REQUIRED) VDOT STD. CURB - - CONSTRUCTED ADJACENT TO w I I euFDROP INLET (DI-3) AMID PT cu rtM Hun Trip L 1.6'S '-- 2" BM25.0 6" 21 A 6 PLANTING STRIP 5' SIDEWALK 3' VDOT STD. ROLL-TOP CURB SECTION A -� I H PLAN SECTION A -A NO SCALE NO SCALE ROLL-TOP CURB TRANSITION TO STANDARD CURB DROP INLET No Scale W Slope break for drainage, if req'd. LL R- 2 Feet @ U a � Back of Curb o C itf N zz If LL i i f dill: : €iitI icons i : wtri Ll Meirline Edge of Poveinent Driveway Entrance Warp Transition Roll top curb Port Plan of Entroncaa Tronaition FIGURE 7 - ROLL TOP CURB ENTRANCE DETAIL Rod.. Return Wap cwD profile to match drive Way entrance awon Qrode _ . { leaf a..H fide of apron 01 imam II Driveway Entranea /Won for Rolllop Carp , Part Section A FIGURE 8 - ROLLTOP CURB ENTRANCE DETAIL SECTION SPECIFICATION REFERENCE 315 STEP 1: DETERMINE DESIGN AADT DESIGN AADT FOR STREET SEGMENT 284 NOTE: IF AADT:5 50, USE MINIMUM DR VALUE OF 6.4 STEP 2: DETERMINE DESIGN VALUES CBR, RF, & SSV SAMPLE NO. CBRT (SOAKED) CBRD RF (APPENDIX 1) SSV (CBRD*RF) 1 4 2 3 4 5 AVG. CBRT 4.0 1 2.7 1 1.0 1 2.7 NOTE: TESTING REQUIREMENTS &RESULTS PROVIDED BY F&R STEP 3: PAVEMENT DESIGN THICKNESS INDEX REQUIRED FOR Q STREET SEGMENT (APPENDIX II) DR 11.0 DR = 3.48Ln (AADT) - 1.48Ln (SSV) -7.23 DR MIN 6.4 DESCRIPTION OF AS -BUILT PAVEMENT SECTION MATERIAL NOTATION THICKNESS, (h) a (a x IT SURFACE SM9.5 1 1.5 1.67 2.5 BASE BM25.0 1 3 1.67 5.0 SUBBASE 21A 1 6 0.6 3.6 DP MUST EQUAL OR EXCEED DR VALUE OP 11.1 / PAVEMENT SECTION IS ADEQUATE 11.> D 0 _ TRIP GENERATION LAND USE: SINGLE FAMILY ITE CODE: 210 AMOUNT: 30 UNITS UNITS: PER DWELLING UNIT WEEKDAY ADT AM PEAK HOUR PM PEAK HOUR 284 IN 8 OUT TOTAL 1 23 31 IN 20 OUT 11 TOTAL 1 31 CLINT W. !: S FFLET a� • F Lille. NerS4380 111, 1111121 • O'.11O ��N04 4,� M E CDO E U N � N C > E »E W �Lu >' U a) 2 LL 0 3 W 0 ^H f0 W UU �_j U00 Z uI�-n O Z> a(A" a I� 2 U zF G,x U �cU U LL 0 a. OU Ln i iu ry Z Fva� of of C On LU M a ct� W to 7 W J UI UI O x cD 0 F 0 W o0 w U DoI- Z O ti O DATE in 0412612021 O DRAWN BY J. FOX } • DESIGNED BY • J. FOX • CHECKED BY : C. SHIFFLE7T • SCALE N.A. �•r_F1 • am U 0 U 0 Ice W Q Z U) (D J > Q W w J LLI Q 2 J 0' °6 J Q W H� O i O J = Z Z < III o U III 0 JOB NO. 47652 SHEET NO. C1.1 Goi 0 3 IL 7 9 0 o� EDO .2O 0 E: mw E HE; a w c NO A a0 0 � N O 3 N Z m O � a F N o r �3 6 N � 2 Y � vmi N 0 PC h N C NG O N O E 0 (a 06 a c Ma 10 a 0 m CO m i (D a c m N C m o c a m GE� 0 N c E F L COVER LIFT NOTCH 12 3/8" WATER CAST IRON LID V NOTES: (1) A 1-3/4" DIAMETER HOLE IS REQUIRED IN THE UD FOR TOUCH READ METERS. TYPICAL METER BOXES (5/8"-1" METERS) NTS FIG. W-7 TDTD13 4" DIAMETER BRANCH AND VALVE - BOX PLUG VARIES WATER MAINS \--RESTRAINED JOINT FITTINGS ON-LINE (TYPE „B") THREADED COUPLING PVC SLEEVE , BRASS NIPPLE AND PVC o CAP I LUBRICATE ALL THREADS THRUST BLOCK Ea METER BOX (SEE FIG. W-7) VALVE OX NO. 57 STONE M.J. FITTING 2" PIPE SLOPED M DRAIN IF GRADE ALLOWS VARIES VARIES 2" BRASS PIPE ,WATER MAIN AND VALVE 2" THREADED TAP ARE SAME SIZE PLUG DEAD END (TYPE "A") TYPICAL BLOW -OFF ASSEMBLY NTS FIG. W-B D)-19 NISHED GRADE AIR RELEASE VALVE BRASS OR BRONZE PIPE BRONZE GATE POSSIBLERADE IFR IH SOLID CEMENT BLOCKS - �v USHED STONE COPPER" SOFT CORPORATION STOP NOTES: 1) A PRECAST MANHOLE CONE AND COVER WITH WATER CAST ON LID FOR TRAFFIC AREAS, OR A METER BOX ASSEMBLY IN NON -TRAFFIC AREAS, OR APPROVED EQUAL, SHALL BE USED. 2) FOR WATFjRLINES SMALLER THAN 12" USE A 1" A.R.V. AND FITTINGS. FOR WATER LINES 12 AND LARGER USE 2" A.R.V. AND FITTINGS. 3) IN SITUATIONS WHERE THE A.R.V. ASSEMBLY CANNOT BE OFFSET FROM THE MAIN AN ADEQUATE FOUNDATION SHALL BE INSTALLED SO THE WATER LINE DOES NOT SUPPORT THE MANHOLE CONE. AIR RELEASE VALVE (ARV) TUTS FIG. W-9 TD-20 NOTE: HYDRANT MUST BE EQUIPPED WITH CHARLOTTES- VILLE THREADS WHICH IS THE LOCAL STANDARD. 1 LENGTH OF BRANCH VARIES 6' MIN IYI2'TD 1d (2701 fjpj1B. 7 CU. FL ALVE BO #68 STONE 42"MIN 6" GATE o °• ", .I VALVE xr TEE 9 2500 P.S.I. CONCRETE BASE AND THRUST BLOCK AGAINST \\vll UNDISTURBED STABLE SOIL. STEEL PILE WHEN THE SOIL IS DISTURBED OR WHEN RESTRAINED JOINT FITTINGS A HYDRANT IS LOCATED IN A FILL, IN ADDITION TO POURING CONCRETE, A STEEL PILE SHALL BE USED AS ADDITIONAL SUPPORT. NOTE 1. SURROUND WEEP HOLES WITH GRAVEL AND KEEP FREE OF CONCRETE 2. MAINTAIN A 3 1/2' MIN. COVER FROM THE MAIN TO THE FIRE HYDRANT ( INCLUDING DITCHES ) 3. FINISHED GRADE SHALL SLOPE AWAY FROM THE FIRE HYDRANT AND VALVE BOX. A THE GATE VALVE IS ALLOWED IN SHOULDER OR BEHIND THE DITCH. IT IS NOT ALLOWED IN THE DITCH. 5. FIRE HYDRANTS SHALL BE INSTALLED AT LOCATIONS WHERE WEEP HOLES ARE ABOVE THE PREVAILING GROUNDWATER ELEVATION. IF REQUIRED TO BE IN WET AREAS, THE WEEP HOLES SHALL BE PLUGGED AND THE HYDRANT SHALL BE PUMPED DRY. TYPICAL FIRE HYDRANT ASSEMBLY DETAIL N.T.S. FIG. W-4 PLACE 5' GALVANIZED " WITNESS " POST WITH CAPPED ENDS PAINTED BLUE IN REMOTE AREAS AS DIRECTED. MARKER LOCATION MAY BE SUBJECT M HIGHWAY DEPARTMENT APPROVAL FINISHED GRADE ---� I 1 � M.J. GATE VALVE WATERrA LINE 6 0 2500 P.S.I.CONCRETEA 2x 2' BEARING AREA. THRUST BLOCK n NOTE : IN REMOTE AREAS, VALVE BOXES SHALL EXTEND SIX (8) INCHES ABOVE GRADE. TYPICAL GATE VALVE NTS FIG. W-5 M-9 1' COMPRESSON x 3/4' MALE PIPE COUPLING OR APPROVED EOUAL 0 •Ir NOTE: NO SMEATED BTTNGS DUAL SERVICE SINGLE SERVICE NO E 1) SADDLES 91ALL BE USED ON PVC PIPE FOR USE ON ATTACHED SNGLE FAMILY RESDENTAL SIERMCES OR DUAL RESIDENTAL AND IRRIGATION SFRVCES �7 R -IMPRESSION A 3/4' MARE PIPE COIPUNG PPROVED EQUAL -OR USE ON DETACHED SINGLE FAMILY RESOENTIAL SOMCE M OE AN IRRIGATION METER IS NOT PROVIDED. IRO! UD _FINISHED GRADE 1/8 BEND CO DUNG-\ ps- METER �.I.A. BIRM AS �:: •C'•4<y :ye`�r •.•AA:!A �' Iv:Y`^.^y+: r. NECESSMY NE 5..v yi.:::a... SAND OR DUST UNDER BOX AND SETTER (2-,NCH :`"=`:?r.N'•a. a 0r3 YDOT SPEC. 203, N0. 67 ''{s.,' 4uYr -' .�T' AGGREGATE MINIMUM TiICNNE55) -. .`.^.,iaT.:,l�h .: ..•a"...a TYPICAL SERVICE LATERAL INSTALLATION (5/8" & 1" METERS) NTS FIG. W-6A TD-10 - ruK cq"uU a BE DMALLLK USE STRAP ON BEND WITH ANCHOR BOLT ON CENTER LINE OF BEND. - FOR BENDS 10" THROUGH 12" USE 2 STRAPS ON BENDS ADJACENT TO BELLS. - FOR 18" BEND USE 3 STRAPS AS SHOWN. ELEVATION PAINT ALL EXPOSED STEEL WITH 2 COATS OF BITUMINOUS PAINT, BEND SIZE A B C D E F 4" - IV 1'-9 2'-3 2'-6' V-2 r-cr 1 Ile Y 7- X-0 2' -6' 1'-6 X-11 1 1 4" 71 1/4' ur 7- X-9 2'-6' 2'-0 S-0 2" 14" 3'- 4'-3' T-O' 2'-3" S-B' 2" te' 3'-B V-6' N-T S-0" 4'-B' 2 1/2" 4' 6B 7-e 3'-0 2'-6' T'-e V-e" 1 I V e" 3'- 4'-3' 7-e' 7-8" 3'-3" 2" t/2' 16' s-3• 5'-6 3'-0 2'-9 X-11 2' 1S' S-W 6'-3 S-0 T-B" 4'-3 2' 16" V-0 7-8 3'-3' 9'-0" 5'-5 2 7/T •4 - s-O" V-0 S-D' Y_3" V-3' 2 1 4 9" S-B W-B S-O' 3'-8' Y-9' 2 1 4' 45' 10" 4'- 7'-e 3'-0' 4' 5'- 2 1 4 12' Y-3 9'- J'-3' 18' e'- 11'- s-9" e'-0 i-3' 2 1 B WILT" = UIM. r CKNESS 0 FILLET WELD STRAP = 1/4" ST U 1 4" THICK ATE WASHEF 3" THREAD, iv 1 NOMINAL INSIDE 3 4" ANCHOR DIAMETER EXTRA BOLTS STRONG STEEL PIPE BARS ®12" IPE B Oy CENTER FO 12' BENDS & CONCRETE CLASS "B" LARGER C CHART FOR UPPER SEC11ON VERTICAL BLOCKING NOTE: STANDARD 90' HOOK ON END OF ANCHOR BOLTS TO FACE CENTER OF BLOCKS. CONCRETE BLOCKING FOR UPPER VERTICAL BENDS N.T.S. FIG. W-3A M-4 6" NOTE: RESTRAINED JOINT FITTINGS. Side View rG(i42" Minimum xnri teel Beam, in. size) •--� 3' min. penetration Into undisturbed soil or as approved by the ACSA. TYPICAL THRUST BLOCK IN FILL AREA NTS FIG. W-3B ASTM A38 AND HEX NUT ASTM A588 (TYP) UNDISTURBED EARTH UNDISTURBED 2 - 3/4" CIA SOIL (TYP) ALL -THREAD ROD a, "•A. WATER MAIN ® 2E �3 VALUE -r - •� ssa . 24" MIN UNDISTURBED EARTH PLAN CLASS A-3 CONCRETE MEGA -LUG MIN �;! .+• 16" a MIN 18" ELEVATION UNDISTURBED " TRENCH 24" RAN WIDTH MIN W � 1 SECTION NOTE: 1. ALL RODS AND FASTENERS SHALL BE GIVEN TWO COATS OF ASPHALTIC PAINT AFTER ASSEMBLY. 2. CONTRACTOR SHALL ENSURE THAT THE COLLAR BEARS AGAINST UNDISTURBED SOIL FOR THE MINIMUM DIMENSION SHOWN. 3. DIMENSIONS SHOWN BEYOND THE TRENCH WIDTH ARE ABSOLUTE MINIMUM. IF THE TRENCH WIDTH IS LARGER DURING CONSTRUCTION, THE COLLAR DIMENSIONS SHALL INCREASE ACCORDINGLY. _C_ROSS ANCHOR RESTRAINTS FOR VALVES NTS Fig. W-30 JUNCTION BOXES, TRANSFORMER PADS, PEDESTALS, ETC. SHALL NOT BE LOCATED WITHIN THE RIGHT DF WAY. VARIES 10' 1 5' 1 1 ._. 1 1 5'. 1 F WATER SEWER 3 O LOCATION OF EITHER UTILITIES (GAS, ELECTRIC, TELEPHONE, CABLE, ETC.) EASEMENT WIDTHS, WATER OR SEWER ONLY - 20' MINIMUM WATER & SEWER 30' MINIMUM III SEE PART 3, PARAGRAPH D) SEPARATIDN OF WATER & SEWER SYSTEMS. UTILITIES CROSSING A WATER OR SEWER EASEMENT SHOULD BE AT 90" TO THE RIGHT OF WAY, UTILITY LOCATIONS & EASEMENT WIDTHS NTS FIG W-1 T71-t GOOD FOUNDATION MATERIAL ROCKY FOUNDATION MATERIAL I UI INITIAL BACKFILL BEDDING 9 STONE * STABLE SOIL ROCK * SCRAPE THE BOTTOM OF THE TRENCH. REMOVE ALL STONES TO INSURE THE PIPE DOESN'T REST ON ROCK AND THEN COMPACT THE SOIL OR PROVIDE A 4" BEDDING OF #68 STONE FOUNDATION IN POOR SOIL UNDER -CUT CONDITION IL BACKFILL 41 MIN MIN. #68 STONE 'ILL AS BY ACSA STABLE SOIL OR ROCK, NOTE 1. NO ROCKS SHALL BE ALLOWED WITHIN 24" OF THE WATER LINES. 2.140 ROCKS LARGER THAN 6" IN ANY DIMENSION SHALL BE ALLOWED ABOVE THE INITIAL BACKFILL. 3.THE INITIAL BACKFILL SHALL BE PLACED AND COMPACTED IN 6" LIFTS. 4.140 ORGANIC OR FROZEN MATERIAL OR DEBRIS SHALL BE ALLOWED IN THE TRENCH. 5.8ELL HOLES SHALL BE DUG OUT IN ALL CASES. DUCTILE IRON WATER PIPE INSTALLATION & BEDDING TUTS FIG. W-2 Y,itel SECTION 1-1 SECTION 2-2 PIPE DEGREE BEND DIMENSIONS VOL TEE AND PLUGS VOL SIZE OF (FEET) W.M. FEE CU.YD. BEND L I H I T I L I H I T 90 2.50 2.50 3.01 0.24 4" & 8• 45 200 2.25 280 0.15 200 225 2.50 0.15 221/2 1.50 200 2.52 0.10 111/4 1.50 ZOO 2.50 0.10 90 3.60 3.16 3.21 0.48 46 266 280 2.77 0.28 8" 221/2 1.66 2.15 289 0.13 3.18 2.91 266 0.32 111/4 1.66 2.16 2.67 0.13 90 4.83 3.83 3.42 0.83 10" de 12" '�` 3.33 3.58 295 0.43 3.83 4,00 283 Q52 221/2 2.33 2.58 2.86 0.24 11 1/4 1 1.83 1 2.33 1 2.84 1 0.18 1. THRUST BLOCKS ARE REQUIRED WHENEVER THE PIPELINE : CHANGES DIRECTION, CHANGES SIZE, DEAD ENDS AND AT VALVES. 2 USE 2500 P.S.I. CONCRETE. 3. NO CONCRETE SHALL BE POURED ON ANY PART OF THE JOINT. 4. THE CONSULTING ENGINEER SHALL BE RESPONSIBLE M THE VERIFY THE TYPE dL SIZE OF ALL THRUST BLOCKS. CONCRETE THRUST BLOCKS NTS FIG. W-3 TD-3 CLINT W. '!i: S FFLET a� • r Lit. NerS4311110 �f4 0 /II/21 �e q*jp • M E 0 0 rn U N � N 0 > E w a E >+ 2 ~vw3 M. 0 3 w 0 m Q_j U00 Z W OU w -N rn O Z> I� a t>/1 ry a In Mu U 2 zF �U �U x a LL p j Z U) = v ry Z OU Fva� ixix 0 rn .U,LU . d d i W LU U7 M 7 o > j uo H Ui EL' 0 2 0 F C] N N LL O O w 2 a OO ti a 813N� Z O ti O Unn DATE > 0412612021 O DRAWN BY J. FOX • DESIGNED BY • J. FOX • CHECKED BY • C. SHIFFLE7T SCALE N.A. • CL U 0 U 0 W Q Z i Fy v J LU I � J >Q V _j W Q C (� J m 06 w r� rLL r O J z Z I� U U 0 LL I� J O JOB NO. 47652 SHEET NO. C.1.2 0 2 TS 3 00 a vX o 0 EZ �0 o � C E a c rn A a0 Oc w G) (7 3In Z n 0 " � a O �3 nm N c Z B �N X C ro16 «- _0 m m C 12 0 d `o E M 0 a c �7' 10 a 0 2.2 c C m u o C O m nE ON c E L ISO FIRE FLOW CALCULATIONS FOR; Date Of Report Hydrant Flow OLD TRAIL VILLAGE BLOCK 7C Service Auth6rity ,�� 7�1/zozi ��;1•TH p /// ��:�, •.>rcd - Test Report SEWER SERVICE LATERAL CONNECTION NOTES: $��� TYPE OF CONSTRUCTION: CLASS 1-WOOD FRAME '' �'° ""' "`''" Inaal sn e; 1 AND NOINVERTELEVATION FOR THE SERVICE LATERAL SHOLE INDICATED THE TOP (CROWN) ELEVATION OF THE SERVICE lbi A. CONSTRUCTION COEFFICIENT: F=1.5 Location ORLON LN J Pressure Zone CRDZET SERVICE AREA , LATERAL PIPE SHALL BE AT LEAST 0.2' HIGHER THAN THE NOTE, MIN, RE DIAMETER MANHULE REQUIRED. ~ 0 L I N T W. BUILDING SIZE: Single Level 4,550 sf 9F- l� Date'ared lr Teat, TOP (CROWN) ELEVATION OF THE THE LOWEST PIPE CONNECTED TO THE MANHOLE. IYI. nrP V $ F F L E T a • m'[s"Of [ 7/1�20219:04:D0 AM EFFECTIVEAREA 4,550 sf a = __- 2. SEWER LATERALS TAPPED INTO AN EXISTING SEWER MAIN SHALL (TIRO DROP MANHOLE PVC CROSS 6 Z - 4w • • Lit. N 543de 4' • Minutes of Flow _ L 2 - BE CONNECTED USING A PIPE SADDLE. ,RY4 oa USE APPROVED FLEXIBLE RUBBER 5t' • BOOT, 1 7Sw CONSTRUCTION FACTOR: C NSTRUCTIO C= 1,821 CONSTRUCTION COEFFICIENT: F=1.5 Pipe SIZeInn]� 12 3. MINIMUM GRADE FOR SEWER SERVICE CONNECTION SHALL BE 2R Q PER FOOT) 02 ' II/ II/ 21 (1/4" 3000 PSI CONC. BASESlo'4. TYPE OF OCCUPANCY: C-2- LIMITED COMBUSTIBLE Educational institution 0= 0.85 pr Ur,IC„_ ydhant 12901. ALL SEWER LATERALS SHALL HAVE A MINIMUM COVER 2' MIN ^ a• ASKETED occuPANCYFAaoR a� DIAMETER OF IV. BENCH SLOPED TO FLOW (psl] 92.1. 5. ALL SEWER LATERALS SHALL HAVE A MINIMUM COVERvaticPressure OF 3 FEEL...rP o - 27'CHANNEL %PEA 1/4" 1' MIN j EXPOSURE(X)ANDCOMMUNICATION(P) X1+P1 -0.00 1 '.• .' PIPE STRAPS o(STAINLESS IdILaIP reSSL(e I 56.2. (P06' SALT STEED n:at * o� SPACED EVERYNEEDED M E FIRE FLOW: NNF=[C][0](1+[X+P]) = 1,545TREATED COEFFICIENT: F=1.5 '-Q211L00 FINISHED GROUND e'VERTICALLY,NR a �.CONSTRUCTION 90' RESTRAINED BEND'•`^{.ped *MAIN - ❑` 0Multi lelnlineH drants ❑0205in IeFlow ❑S rinklerTestSi le Flow`' P Y g P MARKER . •1 \ - Y Y BRANCHEER INFLUENT 7 2 J f ESPRINKLER REDUCTION = 0% .Flow Hydrant #1 127301, Pitot Pressure Ri (psi) 43.3 Yellow 1 ✓❑ Test Flow 1 1110 TOTAL FIRE FLOW NEEDED = 2,000 GPM +' °• / / 1 w v x ?i ...; y • . . A W N Z FlowHydrant #2 1"9C2 Pitot Pressure•R2 (PSiT 44.6 YeIIouv2 ❑� Test Flow2 112W,_ - •"�' • a"•• :••" ¢LL 3 0 W AVAILABLE FIRE FLOW: HYDRANT LOCATION AHS _ _ q- 2„ 0 STATIC PRESSURE 92.1 PSI F O1N H rant/K3 Pitot Pressure713 I YeYe ow 3 ❑ Test Flow 3 01 Y� I_ PLAN '� W s rt V ZO a O U RESIDUAL PRESSURE 56.2 PSI .I _� END OF W J ; ESTIMATED FLOW 2,236 GPM PLUG LATERAL PROFILE o_ to d MODELED FIRE FLOW 3,258 GPM @ 20 PSI Total Estimated Flow (gpnl) 2236 MAIN LINE SECTION SERVICE MIN, 6' BEDDING WITH NO. 68 STONE Cce ry - D W '" O Z O Prepared By: AWWA Q20 Calculation [gpm] 32ss d�Of 1O'Q" 1. HEIGHT OFTHE VERTICAL DROP PIPE WILL BEDETERMINEDBYTHE ACSA,BUT SHALL NOT BELESS THNTWO (2)FEET. FLEXIBLE CONNECTION NOTE: w M � � � x � V � U WITH STAINLESS STEEL ALL CONNECTIONS TO LL w Timmons Group {Ng.a„<m OxomdKnn m,.dr „nP +«•aroP r,,, gzooRy�k �,He �tl 608 Preston Avenue, Suite 200 2. VERTICAL DROP PIPE SHALL BE SDR 26 P.V.C,SRED THESAME AS THE INCOMING PIPEAND CONNECTED TO THE DROP FITTING WITH STANDARD BAND EXISTING MANHOLES SHALL H_ BE CORED AND A FLEXIBLE a In Q C o O V) (/) GASKETJOINT. W . = v to z U > Charlottesville, vA22903 COIrIRMn7S 3. VERTICAL DROP PIPE SHALL BE STRAPPED TO THE MANHOLE AT PIPE JOINTS. STRAPS SHALL BE MADEOF CONNECTION BOOT " v > = Q an O Hy' fan' opened a I' a way.4. STAINLESSSTEEL INSTALLED O F , C7 (n .y W W - SHAPE INVERT AS NEEDED TO PROVIDE SMOOTH TRANSITION FROM DROP CONNECTION DISCHARGE POINT O LU Q W Q W IN LINE WYE-TEE TO SPRING LINE OF MANHOLE INVERT. o_ V) V) r«,nBe."a Wr�wleugaM"i e".,.atN"rBdrgmad,6g r:.M4U;waG§sana t",a•nx Osa lu". iMm�m., �: Ga.m_"Avnw.ra�n�amm6A�,n�rdn,dodxm_I��vwrkalwr" P�g��. PLAN 5. DROP CONNECTION DISCHARGE FITTING SHALL BE ORIENTED AT 45 DEGREES, INTO THE FLOW. TYPICAL MANHOLE PLAN Co J CoH W W ' - 6. VERTICAL DROP PIPE SHALL BE INSTALLED AT 90 DEGREES FROM THE ACCESS STEPS. Estimated Consumption (gal) �7L VARIES 7. MINIMUM 72' DIAMETER MANHOLE REQUIRED FOR A SINGLE 10" OR 12" DIAMETER DROP CONNECTION, OR SHOWING BRANCH TIE - I N N R TWO 8" DIAMETER DROP CONNECTIONS. For use for v: ater a ud'.t SEWER SERVICE LATERAL CONNECTION STANDARD INTERNAL DROP CONNECTION ANTS M 8 SlgnatulleofTester: N.T.S. N.T.S. FIG. S-I-B j " FIG. S-2 FIG. S-1-C2 O TD-33 TD-30 TD-27 F 0 N N w w O O 2 a 0 OO ti Q So ti FRAME & COVER kE ODO O ti DATE r E 1, " FRAME & COVER (SEE FIG. S-I-D,E) V) REMAINING BACKFlLL SHALL` >mE m u SEE FIG. S-I-D, E R Nor1E R D 0412612021 NOT CONTAIN ROCK MATERIAL LARGER g Jpp / PAVED AREA / NONEEPAVEDFAREA O } DRAWN BY 36"MIN THAN 5" IN ANY SLOPED AREA SLOPED AREA -'� DIMENSION E8 �S .':;4, w -,._:;e;tW C11 24 MI EM I 2'-p" RUBBER COATED STEEL STEPS V-O" MAx J. FOX INTIAL BACKFlLL• ,�� k a CAST IN PLACE 1'-O" MAX B"MIN EMBEDMENT (6" LIFTS) • THOROUGHLY COMPACTED g PRECAST REINFORCED CONCRETE 2'-0" DESIGNED BY SPRING LINE O BY HAND OR APPROVED OF PIPE MECHANICAL TAMPER E sx E $ EM o ^o a F= Q " u sEcnoNs WITH "o" RING SEALS a OR APPROVED EQUAL •• • • J. FOX HAUNCHING ° E'" w RUBBER COATED STEEL 3'-0" MIN CHECKED BY N0. 68 STONE _ _ BEDDING �$ 3 g o� 1u X-O" MIN THE DROP CONNECTION SHALL BE STEPS CAST IN PLACE • 6" max min x 0 s 6 o L o DUCTILE IRON PIPE (CLASS 5O 5" 6" LAYERS ND BACKFILLED IBY PRECASTREINFORCED Ji�.e SECTIONS • OUNDATION (SHALL BE REQUIRED WHEN SOIL E CP E- E COMPACTED HAND TAMPERSN OR 1� ° COMPACTED WITH SELFCOMPACTING CONCRETE 12- MIN "0" RING SEALS • 16" MAX T • C. SHIFFLETT SCALE CONDITIONS ARE UNSTABLE m 19TMAx STONE. MINIMUM ELEVATION T • DIFFERENCE ACROSS M.H. 5" 4'-0" ALL PIPE) 5" T �y MINIMUM ELEVATION DIFFERENCE 1YMIN 12"MIN FROM INLET TO OUTLET .' ACROSS M.H. FROM INLET TO VAR I 4 OUTLET SHALL BE 0.20 FEET SHALL BE 0.20 FEET. VARIES • CONCRETE .' A FILLETED INVERT FOR A SMOOTH DEPTH OF FLOW CHANNEL TO BE TFlLLETS • G .'" TRANSITION OF FLOW BETWEEN 3/4 DIAMEIER OF NOTE 1. OPEN CUTS IN PAVED AREAS WITHIN EXISTING VDOT RIGHT-OF-WAY SHALL BE O . ;• INLET & WLET PIPE SHALL BE • i'G PROVIDED. 12 ; • 6' �.., • :.... P... G. _ SEWER. TT "• 12" CON1RIBl1TINGFT BACKFILLED ENTIRELY WITH NO. 21A A FILLETED INVERT FOR A Shoo •,s': STONE. 2. FOR DUCTILE IRON PIPE THE BOTTOM THE TRENCH SHALL BE SCRAPED z 3/4 DIA of LNGEST PIPE IN MANHOLE TRANSITION OF FLOW BETWEEN INLET & OUTLET PIPE SHALL BE M AND COMPACTED, AND ALL STONES REMOVED OR A 4" BEDDING OF N0. 68 $ MIN. 8" BEDDING WITH NO. 68 STONE PROVIDED. MIN. 6" BEDDING STONE SHALL BE PROVIDED' E$ E s E , E o f �� NOTE : All NO. 68 STONE 3-WHERE ROCK IS ENCOUNTERED PIPE SHALL BE INSTALLED ON A MINIMUM 6"g yg m NOTES: BEDDING OF NO. 68 STONE' 25 a 1. BEDDING THICKNESS REQUIREMENTS SHOWN ARE MINIMUM AND SHALL BE 1. BEDDING THICKNESS REQUIREMENT SHOWN IS MINIMUM AND SHALL BE SPECIFICALLY DETERMINED THE CONSULTANT FOR THE SOIL CONDITIONS. RMINE WHETHER MANHOLES SHALL HAVE EXTENDEEDD 2. THEHE CONSULTANT NT SHALL DETERMINE OR NON -EXTENDED BASES SPECIFICALLY DETERMINED BY THE CONSULTANT FOR THE SOIL CONDITIONS. 2. THE CONSULTANT WILL DETERMINE WHETHER MANHOLES SHALL HAVE O o ILL 3. ALL JOINTS, LIFT HOLES, INLETS, OUTLETS 7D BE SEALED & GROUTED AND D OUT. EXTENDED OR NON -EXTENDED BASES. 4. SPECIAL CONSIDERATION SHALL BE GIVEN FOR ENTRANCE 3. ALL JOINTS, LIFT HOLES, INLETS, OUTLETS TO BE SEALED &GROUTED U DESIGN ON SEWERS WITH STEEP SLOPES. INSIDE AND OUT. TYPICAL SEWER PIPE TYPICAL MANHOLE SECTION INSTALLATION IN TRENCH TYPICAL MANHOLE FRAME & COVER SHOWING BRANCH TIE-IN TYPICAL MANHOLE WITH DROP CONNECTION N.T.S 0 NITS FIG S-I-D N.T.S FIG. S-3 Nis FIG. S-I-C FIG. S-I-A O TD-31 1 J 7D-34 •Hp_2A 1D-25 � Z PRECAST CONCRETE MANHOLE BASES SHALL BE FABRICATED IN ACCORDANCE WITH PART V, J SECTION G OF THESE SPECIFICATIONS Of > IL1 PL ROADWAY e SLOPED AREA RUBBER COATED SIEEEI.. STEPS ''` w CAST IN PLACE^,`�'•:-• FRAME & COVER SEE FIG. 5-I-D, E • • ` �'•' , • S ' s . ': LLJ Of LLI (4) 1• (25m"4 mA Haa t th- 4nG1ia2.(eJ1n.")Dv. 2[a99mm] D°i""J O 7• PRECAST REINFORCED CONCRETE •' EXISTING SANITARY ONTCO GHOUSEBRASE •• • SEWER PIPE • Of Q � � Q G O 1 c [BBlmm] -� It7emm1 I` [BOB..] DW7� BDamm SECTIONS WITH "0" RING SEALS OR APPROVED EQUAL 1'-0" MAX 2'-0"' DOGHOUSE OPENING SHALL '•' - a ^'• • MIN. 12" CLEARANCE BE PREFORMED BY • ' '.!• : • BETWEEN EXISTING PIPE MANUFACTURER OR "• •'Y ': •,.„ AND STONE BEDDING SAW CUT TO FlT PIPE ' •'i ;••: - : ''•". LLJ m J J Q ,�ma,,xx W PAVEMENT m �_ za >/I6' I ye- I IF a ANCSAMAY BE APPROVAL�IRm OUTSIDE DIAMATER !.A:. PLUS B". 4 ,' O LL H� > W 36. OR O O 56' DN _--_i a 26• �' WITH Na el STOW BEDDING O 42' MIN. [97.mm7 If•'� [660mm t 1/2' FRAME SECTION [3201 [SBmm] a B"x8'x18" AND 4"xB'X18" SOLID CONCRETE BLOCKS z COATED STEEL BAND OR STAINLESS 42' MIN. 0,25' MIN. THICKNESS STEEL CASING INSULATORS STEEL CASING 12" CONCRETE FILL I 2• (slmm) LETTERS taED�D rws") THE DROP CONNECTION SHALL BE 3'-0" MIN , • DUCTILE IRON PIPE_ (CLASS 501 CENTER W/RIS)ER WALL 4 EACH DOGHOUSE MANHOLE BASE p -- BOTH ENDS 1• BACKFlLLED IN 8" LAYERS N [� U [25mm] NI A 31/e' t/Y' I� : 5" COMPACTED BY HAND TAMPERS OR j BACKFILLED WITH SELF -COMPACTING I..r,nnnn nn,n nr,n, nnnr...nn..... ninn nn...... nn nn nn.... ...„ r. r, u 1 u 1.1 l 1 n 1 n 111 Q I I 3 73/tfi" ► 73/78 Jam_ STONE. MACHOS ABOVE BASE SHALL FILL DOGHOUSE OPENING Iv I 2 tom' [67mm] [676mm] 15 0 26' 12 MIN 16" MAX ELEVATION DIFFERENCE BE CONSTRUCTED AS SHOWN AROUND EXISTING PIPE WITH P9 CONCRETE �. 2'-0' TOR 8' �T DR El'' I 2'-0' 0 11/16. t Sro" [635mm] [17.1 G/16- O.D. OF GKT GROOVE Ale SECTION VIEW MINIMUM e p ACROSS M.H. FROM INLET TO 5" OUTLET SHALL BE 0.20 FEET ON FIGURE S-i-A OR NON -SHRINKING GROUT BDtr 1/4' (6mm) DW SEE..aLr NEOPRENE GASKET D A2 120MIN 12"MIN A FILLETED INVERT FOR A SMOOTH 18' DR 20' JOINT OF DS, UCTILE IRON PIPE I _ I ESTRAINm JONTS) (z) wslR 1/15 x s/a x t 1/2 `SEW R PC [SmOm' RUBBER PARK W9Bt045 t 8/e" (2) BLT Hoc 5/e-11xa 1/2 ss VAR •. 4 TRANSITION OF FLOW BETWEEN •• INLET & OULET PIPE SHALL BE ALLOW CONCRETE WRAP EXISTING PIPE WITH Q 2400' [4tmm FAARTY 009e1250 1/2' '"• PROVIDED. 1' FLOW A MIN. NEOPRENE GASKET MATERIAL 1-0" BEYOND BASE NOTE 1. STEEL CASING TO EXTEND TO BACK OF CURB, DITCH, SIDEWALK, ETC. OR A MINIMUM OF 5- BEYOND THE EDGE OF PLAN VIEW 1 i/6' (2gmm) DU BOSS [6mm [H3m .y OLl STANlFSg STEEL ROD RAARTN�00gErwa tw $ .6 __ FITTING DIMENSION VARIES WITH SLOPE. OF STRUCTURE BEFORE RULING THE OPENING PAVEMENT, WHICHEVER IS GREATER. 2, ENDS OF CASING CAN BE SEALED USING APULL-ON END SEAL GASKET IN LIEU OF CONCRETE FILL, PICKE:AR S LOCKLUG HOLE DETAIL NOTES: z) W Nx s n' "P • i• ,'t'.Q 12 �. C•: i "• . e �••' A' NEOPRENE SECURED BY 2 NON - CORROSIVE STRAPS, 1 ON EACH SIDE OF OPENING O 3, MIDDLE SPACER SHALL BE PLACED AT THE CENTERPDINT OF PIPE JOINT. rvRrY ON 12A11 1. ALL MANHOLES WIGIN 100 YEAR WATERTIGHT C WN OR LOCATED IN ABED. SUBJECT R1 FIAOpINB SHALL NAVE MATFRIIGYT FRAME " COVER (2) NUr to JUR 5 a-11 M E DLSIGF TOR COVERS P7x51SNUA / 1 CO 3. CDVEPS SHALL BE FIXED TO FRAMES WITH LOOMING LUCS DR 9WLWt A55FNS.Y. Pnrsr/ 00991128 IS SHA O RAISES LNG LU CIA LARGEST WATER (2) 1955R LOCK LUG TYPICAL WATERTIGHT (Sam Pj ODIMN A PIPE IN MANHOLE PIP 12" MIN. CAST -IN PLACE 3,000 PSI CONCRETE BASE TYPICAL STEEL SLEEVE INSTALLATION MANHOLE FRAME & COVER LOCK LUG ASSEMBLY MIN. 8" BEDDING WITH N0. 68 STONE FOUNDATION SECTION VIEW UNDER ROADWAYS N.T.S FIG SHE NOTES: 1,11II..................„........ 1111,I1,IIII,I,II,IIII,I,II,......i....... l................ l................. . TD-32 1. BEDDING THICKNESS REQUIREMENTS SHOWN ARE MINIMUM AND SHALL BE NOTES; N.T.S SPECIFICALLY DETERMINED BY THE CONSULTANT FOR THE SOIL CONDITIONS. Fir. W-10 2. THE CONSULTANT SHALL DETERMINE WHETHER MANHOLES SHALL HAVE 1. CONSTRUCT A FORMED INVERT FROM NEW SEWER LINE TO ALLOW EXTENDED OR NON -EXTENDED BASES 3. ALL JOINTS, LIFT HOLES INLETS, OUTLETS TO BE SEALED & GROUTED FLOW TO THE EXISTING PIPE. INSIDE AND OUT. 2. POUR A SHELF TO THE LOWER HALF OF THE EXISTING PIPE. 3. CUT AND REMOVE THE TOP HALF OF EXISTING PIPE TO WITHIN 6" OF THE MANHOLE WALLS AFTER THE INVERT AND SHELF HAVE BEEN FORMED, AND THE MH HAS BEEN FULLY TESTED IN ACCORDANCE WITH THESE SPECIFICATIONS. TYPICAL MANHOLE DROP CONNECTION TYPICAL MANHOLE BASE JOB NO. WITH STEEP INCOMING SLOPE SHOWING "DOGHOUSE" INSTALLATION 47652 NITS N.T.S FIG. S-1-CI FIG. S-1-All SHEET NO. C1.3 M-29 TD-26 0 m 0 3 c OL 7 9 0 O DE C7 ED �Z .2O c m w a c m m a0 O c O w CO 3u) Z m O � a F DO o r �3 CL dm .Z Y RD m � m X C 0.0 016 IS DO m 0 0 m o E `o DO0 6 a c �a 0a D o 2 DOm � a c m m c m O c DOo nE c E F L \ '12 w \ \ S MHS \ �\� TOP=682.73 ci C&G ` _ \ \ 12" INV _ PVC 1� -� \\ - W �' INV OUT6665.23 8"PV(C (NE) O O O O u, n '_ET W/GRATE EP - - - - - _ 12 t7 , ' ao o0 0o ao t+ TOP=681.26 \ -682 - OL 7-RAIL A a a a nl 1 15" RCP (SE) - OR/VE CA, "'oh o (zy� �wvrvaoro 0 -f- - -- -- - ---__ (VA R/ABLEW/DTHR/W) \ `\ � _12„w_ U 4556, PG.173 ALB E�IS -sg DB. 4038, PG, 704 - _ SD CURB INLET W/ GRATE - - C&G MANAGED STEEP SLOPES TYP °p v v v ~ 683 `\ \ I ( ) N N N b to r DB. 2886 P T0�682.34 \ 6813' - SD CURB INLET W/GRATE - _ _ G. 134 \ EP INV IN=�B 24�a"_f3�2 (SEA \ \ P n --------y'-� ---- = „R / _„_ INV OUT-678.1915 P7` w'�_ \\ _ MHS TOP- INV OUT=684.40 15" RCP (SW) \ ----�- - / -------- ---- _ \ \ CON'C'.SWLK -- -___ s-`w J >,.'-r.. ..\ '°�:.682.9'--_-___ \ `\ `� _683 \ - _ `-683 TOP87 �_ INV - 7.17-8 GC(SW) MHS 10 1 / CSG 688.7- INV OUT-666. 97 Q' \ %NV-iN=66&48 8" PVC ) 0� '6 \ 7/_----682-----\ I _ _ a__ _ MHS / �e EF oD s� ` INV OUT 667.7018" P CIE) SO CU6 l W/ GRATE TOP=683.54 > pI.\ 59/8' PVC SE)-HAM-INV 1N=680.70 15" RCP SE) NOUT675.448PVCjW-- -F/ - --COORDINATE INVOUT=680.6015"RCi%NW)- RELOCATION OF i ` a ---------------- --- ------ v \ TRANSFORMERS WITH DOMINION POWER_ \ VARIABLE WIDTH _ I \ \ REMOVE • .., 86 R D (F) STORM EASEMENT _ _ - -683 - - - - - - - _ _ _ \ e \ 48" RISER ll DB. 5074, PG. 234 J 1 s� \\ \ I TOP=679!39 - / />CONC r l / 20' STORM I I \ \ INV 00t=669.99 48" R P (NF� - - _ _ _ - "SWL EASEMENT \ \ REMOVE PORTION DB. �30, 4, PG\234 \ \ / \\ sg OF 48" RCP PIPE - - - 682-BENCHMARK \ ' Pk NA_IL INSWLK. � \ I_ / � \ \ I I C ROCK 19" RCP\ s)9 _ - I ARMOR INK(=672.8\ \ \ \ \ I TMP 55E-01-7B-0 / - 682- - , I R �I�VE� _ I I _ MARCH MOUNTAIN PROPERTIES LLC / I `s�� I 4 681- - - DB. 4954, PG. 18C / 1 \ \= ��\ 1 680� / \s\a, ) /I / 1 \` ` REMOVE OR ON \\ \ 1 I \ \ I ZONED: SF , I sB, T - - _ _ - _ �6 / /' / f I IOF GU ERIC 6 -� \ \ ILI - \ SAM, I (' 0 Dtn / VACATE I I/y _ \41+ I 20'SANITARY I / ses_ `,e \ ` _ ` ` _ _ - EASEMENT ' 1 / - - ssf- - . - - - - 685 5 / DB. 5074, PG. 234 I 1 I II / - - - - - R/MOVE PORTION 1 _ 682 - 1 ` \ I ' 1 / I 'HOPE \ °� m A INV=679.03 ' I m 1 \ I / I VACATE -- / \ 0 p / 10' STORM \ 1 \\ \ \ \ \ III 0 1 ` 1 I / EASEMENT DB. 4704, PG. 389 / 20' STORM EASEMENT \ \ \I1 \ 1 REMOVE PIPE ` � / 6$ I 1 \ \ \ ' / , I DB. 5074, PG. 234E 1 GF AVEL WALKING TRAIL 1\ (ILINDYBAIN LOOP) \ REMOVE MHSVACATE 20' STORM ° TOP=682.33 \ INV 1N=668.63 8-PVC (SW) \\ \ I \ \ \ \ EASEMENT INV OUT=668.33 8" PVC (NE) \ \ �\ / DB. 5074, PG. 234 , \ \ \ I / � � REMOVE/ EDGE \ \ \\ ABANDON PIPE IN PLACE \ S ---_ -_ ---------686 OF GRAVEL \ 1 \ \ 1 \ USING FLOWABLE FILL \ \ \ - \ \ REMOVE \ REMOVE FHA & \ \ \ \\ i \2p' I`\ EDGE'\ \ WATERLINEF -666 \ I ( I \ REMOVE MHS S \ OF GRAVEL TOP=683.44 �` \ \ / I ` \ \ \ SO CURB INLET W/ GRATE INV IN=669.44 8" PVC (SW) \ \ 'sue \ TOP=682.03 N INV OUT=669.04 8" PVC (E) \ 1 \ \ I \ \ � INV 1N=675.03 30" HDPE (SE) \\ I TI _II N28°1477"W `\ I \ \ \ ` \ ll�V OUT=674.30 30'HDPE (NW) OD F\\ I \ \ \ I 323.58' v 398.58 (TOTAL) ABANDON PIPE IN PLACE I Z \ \ -) i \ Q \ 0 \ \ \ USING PLOWABLE FILL \ \ N \ D // N7 5� 685 .,'ROD REMOVE PORTION OF REMOVE \ \ \ GUTTER/CURB/SIDEWALK SWMFACILITYL-1 \ \ \ \ \ \ \ REMOVE \ / GRAVEL (F) TO INLET SD CURB INLET / GRATE (RETENTION BASIN II) \ \ \ \ \ \ \ \ 20'SANITARY \ \ - - - _ EASEMENT , TOP683.73 DB. 4704, PG. 389 \ \ INV OUT=678.03 15" HDPE (SE) \\ \\ \\ \ \\ \ \ ` \ /68\ \\ \ \\ `mow \\ \ ^/h 1 . / h \ REMOVE SIGIy \ 684.2' APPROX. W.S.E- \ \ \ \ • / \ \ \\ \ TMP 55E-01-35-D1 / \ �h' oh I b 682.7' \ CO +/- 672.60 PER \ \ ` \ \ \ MARCH MOUNTAIN PROPERTIES LLC \ \ \ Z e, MASTER SWM PLAN \ \ \ \ \ \ \ \ \ \ \ Q /y q III (WPO201600009) \ \ s \ \ \ DB. 5024, PG. 441 \ \ N \ a3- 1 R ZONED: SF REMOVE`PORTION OF / \\ \ \ '6 `k/- \ I IIIIIIIIII � /6v II I II \ II \ I L / SD CURBIINLET W/ GRATE \ ok INV 1N=684.04 15" RCP (NE) \ INV 1N=683.74 15" RCP (SE) \ INV OUT=683.69 15" RCP (NW) TMP 55E•01-7A-26 SOUTHERN PROD€RTIES LLC DB. 5071, PG.,231 MHS \\ TOP=68714 INV 1N=676.99 8" PVC (SE) INV 1N=676.84 8" PVC (SW) INV OUT=676.74 8" PVC (NW) 1 i 1 S SD CURB INLET W/ 1 TOP=687.94 INV OUT=681.54 15" � / .____________.1__A L_________ -FENNM�RQAD _ VARIAB4E WIDTH ICUT (PRIVATE)R/Wr DB_5074_IPG.2341C/�/ --- - __ - ---'Il I I VARIABLEI WIDTH WATER EASE ENT DB. 5074 P 234-- I SD CUkB INLET W/ GRATE TOP=68787 INV IN=1580.67 15" HDPE (E) INV IN480.82 15" HDPE (SE) TOP=685.49 I INV OUT=680.57 15" HDPE (NW) INV IN=6779918"PVC (SE) INV OUT=677 b4 8" PVC (NFI) o I l I FQ I ) GREIENWELL LANE f I / 24' (PRIVATE) RAN - - SAN- 1 DB. 5024, PG. 429 I , __ ----- SD CURB INLET W/ GRATE TOP=683.93 INV IN=677 63 15" HDPE (NW) INV OUT=67761 15" HDPE (SW) GUTTER/CURB/SIDEWALK \ \ III 1 l /f2�MOVE SIGN F/' - __ __--__ j I� \ _ L i OR, PORTION OF- \ \QP=683.2 UT / r/ / Cq REMOVE ' 3� /pUe /`/`-SIDEWALK EC684- INV IN=670.0 8",dVC (SW) � l D C INV OUT=669.93 8"'PVC (NE) / Q 4A0,7L7 %R/4y NFW FNTERNAL I 38 CONNECTION 9 ANDCG,12 144 R D F, \ \ VARIABLE WIDTH / () � �ro \ \ \ \ I I I SANITARY EASEMENT / `t > 1 / 4t C 'fG ` / \ \ \ I I DB- 4704, PG. 389 � / �, 1 O � IN ROD i I I / / R D (F) Q Ci Qo. -> SD CURB INLET (F) N29°4641"W 0/Q 48"HDPE 155.24' Qh TOP=682.55 " HDPE (NE) \NV=671.85 INV=T74.2530 INV OU=6.80 30- HDPE (NW) ma ----- - - 01 SD CURB INLET �r MHD V I / l TOP=682.00 ___ ______ _ __ ___ _ � - 1'j(6) I /`,/[ INV lN=673.7030"HDPE (SE) -------- -------t---4-1 _ _ - - - -t- '- ---I- - - 'DECIDUOUS l l INV OUT=673.5030"HDPE (NW) INV IN=6771015"HDPE(SE) ------------- - -- -- =� _----------------------------r----------- / - - ' ' lNVlN=676.5524"HDPE(SE) 1 \ / I , , ` \ _ (REE (TYP) / INV 1N=676.58 15-HDPE(SW) INV OUT=676.50 30" HDPE (NW) 1 I 1 (OPEN SPACE) I _ I SD CURB INLET TOP=681.81 1 I I 20' STOI7M TMP 55E-01-35-A S 4 I_I _ _ - _ ' INV 1N=673.26 30" HDPE (NE) I MARCH MOUNTAIN PROPERTIES LLC I SO CURB INLET W/ GRATE /NV OUT=673.2136"HDPE (NW) I EASEME T I DB. 5024, PG. 441 MHD TOP=681.03 I DB. 4704, PG, 3 9 II TOP=682.37 I I INV 1N=673.18 36" HDPE (SE) I I ROD INV 1N=672.62 36" HDPE (SE) INV 1N=673.63 36" HDPE (SW) LEGEND: REMOVE ASPHALT ® REMOVE CONCRETE - - - SAWCUT SCALE V=20' 0 20' 40' CLINT W. '!i: S FFLET a� • Lic. N 543dd ��4'� 11/II/21 • O'"0N"wpooAt�N� %,� ^� E 0 o N � N C > E w ° E Q LL tj o 3 p LL w o m O j L f"l < Lu V oo J - uj 00 .. rn C7LuNV vm 30V)x oa =LL U-)= N =v>� F a C EO1 N 00 W M ti w z0 U CL U � � U 0 � Z �U U a a Lu w� ct� ct� Lu 0 DATE 0412612021 DRAWN BY J. FOX DESIGNED BY J. FOX CHECKED BY C. SHIFFLETT SCALE 1"=20' J U o 0 0 m z O 1 (D 2i Lu W rw/ p LL 06 r Q � J m Z J a O LL H o �-- Q J 0 o O i--i <� u U L.L Q z_ C) U) J X O w JOB NO. 47652 SHEET NO. C2.0 L \ ~ 1 lW NOTE: — C&G ` _ \ \� 1z"W FRONT, SIDE, AND REAR SETBACKS � .11E�LTH 0i ow EP --_ \ \ O O O O O cn ARE 0' IN THIS BLOCK 0 gyp„ W — _ � �o pp 00 0o Oo �+; � 'i I _ ilj DEVELOPMENT. BUILDING CLINT W. GL TRAIL D c N r SEPARATION SHALL BE A MINIMUM • \ \ —��z °j CV 7S FFLET a• \ R/VE \ z W — — (VAR/gB�EWIDTHR/W \ \\ Q — " w a 0 OF 10' PER CODE. \ 49 DB. 4556, PG. ) C& — 12"w ALBEMARtE-EBUNT_YGIS d)) ` Z i . Lit. N 543de `v i DB, 173 ADU: ACCESSORY DWELLING UNITS 7Sr � 11/11/21 �� 4038, PG, 704 I \ \\ G MANAGED STEEP SLOPES (TYP) N V v � s G ,• °D OB. 2886, PG, 134 \ \ I f' n ,��i S�O!1AL t �0% C&G M E BEGIN 10' TRANSITION FROM _ ' �EP N c / ROLL-TOP CURB TO CG-6 E (SEE DETAIL ON SHEET C1.1) - - \ \ w > E \ � ai E LOT 39 N , �� , > \ ~ v w 3 Z 2166 LOT 38 - I \\ '•------------------------- - / SQ. FT. 1719 LOT 37 I \� ° o G ti SQ. FT. 1726 LOT 36 I S _ ------ --------- �- // \ SQ. FT. 1721 LOT 35 I ° a v Lr; z W OU SQ. FT. 2084 ° -- --_- w „j - O SQ. FT. I - W w a U j / \ \ LOT 34 _ _ - _ - tr. \ : 0 w 2 a (/( \ 18' DRIVEWAY 2021 L T 33 r b. > OJ a < In LINE (TYP) I I SQ. FT. / S1Q. FT . L1O6182 LOT 31 I I x v ry z 21' I ( I 1 I I I / / SQ. FT. 2014 SQ. T. I LOT LOT59 LOT 28 LOT 27 ~ v o rn a a CG-6 - I I Q -SQ. FT. v w w 1640 > I I�I I I z "NO PARKFAIG SQ. FT. SQ. FT. 2084 w w p I III I I SIGN °' J » - _ TMP 55E-01-7A-26 W W _ I I "STOP" SIGN _ _ SOUTHERN PROPERTIES LLC DB. 5071, PG. 231 I/ R25' R608 W - _ I ` I _ j I I I I SIGN PARKING" BEGIN 10' TRANSITION FROM O _ _ �I , I _ ROLL-TOP CURB TO CG-6 = -� --�--(SEE DETAIL SHEET 1.1 c� END AD MARKERS R50' �-_�- -i W.. - II _ I I " I ) 0 (STAJDARD OM4-2) AN _ - J \ \ SAN-, _ ggppy _ o CLDOT ASS TD` I \ \ ' (VARIABLEE EL' O - _ TIE TO EXISTING > w N N R25' 8' WIDTH PRIVATE SAN - _ ROLL-TOP CURB = Q o R PRAPBROMSTONE 1 \ o ° I _ 8-�_� ---- TIE TO EXISTING PAVEMENT ¢ CIO WIDTH =9'\ I I "NO PARKING" SIGN I R25' g„W --'--� L_ --SA 26 —SAN- ----_ VDOTSTD.WP-2 0 0� WIDTH =29' _r - —SAN— _ S v\ DATE LENGT = 20' _ "W - — — SAN— — _ > \DEPTH �19„ \ II II =1 v LOT 40 I C 12 ° I— - - 7 D y 4282 I . ���_ _ - _ �^' \�FENN€L—RQ,AD j / 0 04DRAWN BY l 1 TIE 5'1SIDEWAL —1 0 - _ ~ SQ. FT. ROAD SIGN - ^�^^•��' - — NARIABLE WIDTH TO \STING LIND Z m 1III "" --- - _�`j� VAR/ABLE WIDTH 7 o D - II I '-^ IN Z (PRIVATE) RIW r _ % J. FOX SWM F CILITY EASE�AENT IN LOOP 1 I _ „ DB. 5074, PG. 234�C 7 \ � I VDOT - „ _ I I �- ¢ 1 STANDARD R-1 I I DESIGNED BY v �STOP SIGN ROLL-TOP I ~ _ _ I W'. w _ ` . I J. FOX T e, 1 _ CURB 1 •• I I 03 A i[ \ "NO ARKING" I =- ' ? 1 m I I I CHECKED BY A LOT 41 \ SIGN I� I • I \\ 1 \ \ \ \ 3122 . , LOT 47 (ADU) 18' DRIVEWAY I �; I I • C. SHIFFLETT I \ 2445 LOT 48 LOT 49 LOT 50 LINE ROLL-TOP I • • SCALE SQ. FT. 1 \ 11 \ \ \ SQ. FT. 1738 1735 LOT 51 (ADU) I CURB 1732 \�� Z I I • I ., = 20' SQ. FT. SQ. FT. SQ. FT 2203 I LOT 52 (ADU) LOT 53 SQ. FT. 2145 LOT 54 LOT 55 1 GRAVEL WALVONG PRAIL\ ----- I _ - SQ. FT. 1732 W 1 LOT 56 (ADU) (INDYBAIN LOOP) ° I �_ _ SQ. FT. 17321730 I I I • \ �y\ \ LOT 42 a \. I -� - -I SQ. FT. SQ. FT. 2016 I I 3307 \ I I I 11.3' I SQ. FT. TIE TO EXISTING 3' I I SQ. FT. �_ ROLL-TOP CURB001, I I \ � <a °d I 41 a \ I 9p 2l, FA yB��O� 8 "NO PARKING" SIGN \ \ 11 \ 1 1 LOT 43� mob\ 5' SIDEWALK II GREIENWELL LANE (, a I 5549 'yw a 1 a I / / 24' (PRIVATE) RIW 2� l \ \ 1 \ \ A a (�- — —SAN— F- / DB. 5024, PG. 429 1 \ I 1 SQ. FT. bS G�! 5' SIDEWALK / \\'' v i �`�` ���` U PLANTING STRIP \ \� d 3' LEAD WALK (TYP.) W O II \----- 0 "NO PARKING" SIGN o �C9 1 II I 12 2' GREEN/OPEN SPACE a V J (10,750 SF) Q h 4 Q Q Fy cG s� cG-s6 h I Z w? Q LOT 44 a ` a . a CG-g THE TO EXISTING P" SIGN e O N (� _ 5333 8„1/v r CG-6 CURB &SIDEWALK Q g LLJ SQ. FT. h ` J m i _ O 30' _ CON` (! -�-__= J LL \ \ \ \ \ -q'o� LOT 45 / l l EP _ CG-12 �o 3976 6' PLANTING STRIP 5' SIDEWALK R25' CG-12 \N\ \ illj a= _�� J p \ \ \ \ \ �oILZ G� i I SQ. FT. �\ v — \\ \\ • \ \\ \ oo/G�� ROAD SIGN \`c. �� \\ \8 6�. I I 2 \' " TIE TO EXISYI G PAVEMENT ORIOAV I I \ \ \\ �k f ` - h \\\\, VDO�ST W 2 pe �P(�g�7C'QNE L.L rn� I LOT 46 ,\\ / �04, 6835 \I\� FPW PG 389 SQ. FT. �\�� � ,—' ;— � � � LEGEND: 0 \\ \ \ \ 18' DRIVEWAY Q 42 O C8G \\ LINE j Q EXISTING CG-12 MILL AND OVERLAY O TIE TO EXISTING CG-6 CURB & SIDEWALK Ci C7' ^ VDOT 04 4 Q� / STANDARD R-1 0 HEAVY DUTY PAVEMENT \\ \\ 11 PARKING STRIPING , QJrp^y" / �/ STOP SIGN LIGHT DUTY PAVEMENT CONCRETE SIDEWALK --------- _ ----r�------------------ '� `1„(6) -------- ---- --------- DECIDUOUS ------- -----o-------------- ----- TREE (TYP) I _ 8 1 I 1 ADJUST OPEN SPACE PARCEL 4 1 £ JOB NO. ObN 47652 11' I 11 TO COINCIDE WITH EX. STORM EASEMENT S j j SCALE 1"=20' SHEET NO. 1 I 1 I i t 0 20' 40' C4. Q L C& G EP � tz) tZI t� 12.1,1,— ° N m _ �L %RAIL OR/VE \ — — —12"w— o � � o c y' (VAR/ABLE — — " w - a W�' I IDTHR/W Z — —,2^W— — OB. 4556, , ¢�� d) � P ` Z G173 � C&G No,www y DB, 4038, PG, 704 °D DB. PG 2886, . 134 P I I EP - - - - - - ----- - m J NOTE THIS SHEET IS PROVIDED FOR INFORMATION ONLY TO ENHANCE CLARITY OF EASEMENT AND PROPERTY LINES. THIS PLAN IS NOT INTENDED TO BE A PLAT. SEPARATE SUBDIVISION AND EASEMENT PLATS WILL BE SUBMITTED FOR APPROVAL AT A LATER TIME AND FOR USE IN RECORDATION& CLINT W. '!i: S FFLET a� • Lit. Nfr54380 49* 11/11/21 • �3.110 ALtN'� ,% v� EP "r c \ E V/W LANDSCAPE _ v °' '^ ; 2 MAINTENANCE _ _ 'II—' a�'\\ a LL 3 w - -- EASEMENT (TYP)LL ----------------------------- o s -------�_--__---_ \ ¢ v ? U - _ W or'o Lr; z °. x 20' ACSA V/W SIDEWALK I x> Z o (1 SANITARY , ,r ry v O V> • • 1 I MAINTENANCE I > _ � .. � ix '1 EASEMENT I I EASEMENT (TYP) id►�1►•map ►�'`�'° IPA .-� .�.�up �.gpaa��dII,►�►d►���t�'��► Ali ,ACSA UTILITY EASEMENT SRI/�,�i L96416A S54K�YeiAa�V,,�\�'�I,�'d►/►•1(5- BEHIND ROW TYP. I r.It' I ���:pd►d�►.�►�/►`>;'�II►�Ip►�►`'aa- ��..�,� 11�;�fIP 1 1 :'a;'t�t�♦�d► -Ci{1%�C'i�►1�/�/��►�i,�l►►i►-��_�— ys WNo0 C H rn Lu a� W� M v W J ul ul 0 x c� 0 x \ SAN Lu 20 PUBLIC — — _�ZZ STORM EASEMENT \ I _ - - I —1 a z oti ODATE —SAN VARIABLE WIDTH— -----------' -------- / 0 0412612021 LJQAD 1 PRIMITIVE TRAIL EASEM NT ^ y _ _ I — — — — — — I ENA / DRAWN BY I I , + W1VARIABLE WIDTH VARIABLE WIDTHtz, (PRIVATE) IW / J. FOX SWM FACILITY EASEMENT o v - _- -----_ ---- -- iZ DB. 5074, PG. 234C / DESIGNED BY -- `' ---------- J FOX - \ m / ------ I I m I I I A �--- V/W ACSA SANITARY 20' PRIVATE L-------� ' A CHECKED BY EASEMENT STORM EASEMENT I • V/W PUBLIC I II I • C. SHIFFLETT STORM EASEMENT I I I • SCALE \ \ I • 1"=20' co GRAVEL WALKING FRAIL \ \ _- I _ (LINDYBAINLOOP) GREENWELL LANE (, I I\ \ 'a' 24' (PRIVATE) R/W • LS}— — —SAN— ' 1 a " _ — — — — — — — — — — — — — — — - VNV ACSA I DB. 5024, PG. 429 LANDSCAPE EASEMENT (TYP) � \ SANITARY EASEMENT L�1 U z Cc J a \ O W c; m a J \ / 8 10' PRIVATE Q LANDSCAPING h W > z i - Q o m \ \ i EASEMENT I� J N O 5w \ de 41 de C W LL L d d I11 4.D q,r II co NLLJ COw N` L IfEP_ _ _ I J Q up Oq PG 3R 9 LEGEND \/ l PRIMITIVE TRAIUMAINTENANCE EASEMENT CfG ElACSA SANITARY SEWER EASEMENT p \� ; J ♦^' Iry / LLLLJ ASCA UTILITY EASEMENT LANDSCAPE MAINTENANCE EASEMENT / If PUBLIC STORM EASEMENT � ' TREE(TYP) � lid JOB STORM EASEMENT — \ I - JOB NO. sell 47652 \ I I SCALE 1"=20' ) I I SHEET NO. 0 20' ao' FM C4.1 L C&G \ '_ETW/GRATE � EP TOP=681.26 \ 1 15" RCP (SE) ' 15" RCP (SW) COORDINATE WITH AC TO LOOP / WATERLINE UNDER EATH OLD TRAIL DRIVE TO THEE STING 12" \ \ WATERLINE EAST OF OLD TRAIL DRIVE. 12" x 8" TS&V TO �E USED. \ FHA 8" x 6" EDUCER 301 15" RCP \ \\ \\ S MHS MANAGED SLOPES \� TOP=682.73 12'W INV 1N=665.73 8"PVC (SW) INV OU 6 8" PVC (NE) (` @ t:1 t� th OL H m TRAILOR/V (VAR/ABLE E \ \ W/DTH Q R/6yJ \ DB. 4556, PC,, 12„ W _ U 173 SO CURB INLET W/GRATE DB, ¢p38, PG, \\ C&G ALBEMARLE-EBfJAIFXGIS 7p¢ TOP=682.34 \ OB. 2886, PG. \ I I MANAGED STEEP SLOPES (TYP) N V v r CURB INLET W/GRATE EP 134 \ INV 1N=678.24 15" RCP (SE) \ \ P n SD INV OUT=678.19 15" RCP (NW) \\\ \\\ W TOP=688.50 I MHS m INV OUT=684.40 15" RCP (SW) \ \ I TOP=682.87 • " > ° '. a \\ \ INV 1N=66717 8" PVC (SW) MHS C&G INV OUT=666.97 8" PVC (NE) TOP=683.10 INV 1N=668.48 8" PVC E) EP �- Rap INV 1N=66790 8" PVC (SW) SD CURB INLET W/ GRATE MHS 11.25° ' INV OUT=667.70 8" P C (NE) TOP=684.60 OP=68 .54 BEND _ I I ,, > . °, \ INV IN=680.70 15" RCP (SE) 5.59 8"PVC (SE) a U /// LOT 39 - ' , '> \ \ " INV OUT=680.60 15"RCP (NW) INV OUT=67544 8" PVC (NW) LOT 38 - - I I ° ' \� '. '' - �n LOT 37 LOT 36 I s 'Rcp ----�- LOT 35 I - - ° ----_-------_---- 15" RCP I LOT / - _ _,_ _ ° >CO4v�aIN .> ... .' L L 33 - - ° > ° ACSA MANHOLE# OLD-TRL-VIL-37-1. TIE ' LOT 32 -- - _ _ INTO EXISTING SSWR MANHOLE. ' f I I / / LOT 31 I \ \ SD CURB INLET W/GRATE I I I CONTRACTOR TO NOTE THAT MANHOLE I / I LOT 30 LOT 29 ` LOT 28 ____ I MIGHT NEED TO BE REPLACED DUE TO I LOT 27 INV 1N=684.04 15"RCP (NE) 'INGLE TAP ' L REVISED PIPE ANGLE INTO THE MANHOLEINV I z °' _ WM (TYP.) \ IL ........ III - - - - INV OUT8683.69 15'CRCP (NW) 1 - - - SOUTHERN PROPERTIES LLC - DB. 5071, PG. 231 - - I MHS =672.27 8"W - I I I 302 � - - L '-- - i i 12 TOP=68714 8"W -� ---- ------ L EXTEND EX. FH -i -------- AS REQUIRED INV lN=676.998"PVC (SE) 3 - I TO AVOID CURB 22.5 +45° - I I INV 1N=676.84 8" PVC (SW) I \ \ BEND - --- INV OUT=676.74 8" PVC (NW) 300------- - SD CURB INLET W/ t � - L VDOT $TD1 \ \ SAN SAN 304 SAN - TOP=687.94 i ------ - -----� TIE TO EXISTING CLASSII \ \ 450 8" WATERLINE INV OUT=681.54 15" BROWtSSTONE I I \ BENDS SAN - 8" TEE 3 6 (WM FACILITY L-1 ) 8 - -- I -' ------ RETENTION BASIN II - - SAN - 1 APPROX. W.S.E. il `i---------- --S-A--N- ---- - - 8" W s SAN- ! +/- 672.60 PER ------------------- - -�-- L�' -�--LOT 40 a"�MASTER SWM PLAN BEND 30 FENNEL ROAD1 (WP0201600009) ------- _8y1 % 318 -------- - - ----- 310- VARIABLE WIDTH VARIABLEWIDTH N 0 SWM FACILITY EASEMENT z (PRIVATE) R/W r o DB 5074, PG 2341C� --------------- -/-- -/-\/ / 1 / 316 [-N m68 ----_--- - I -- i1I 8' CL 52 i 1 IL------ -----' I m LOT 41 LOT 47 (ADU) WATERLINE 1 L25° BEND II 11 I \ \ 4" SSWR LOT 48 CONNECT NEW LATERALS LOT 49 LOT 50 11 \ \ LATERAL LOT 51 (ADU) I INTO EXISTING SSWR MAIN I I 1 crYP_) 7;� I LOT 52 (ADU) ' LOT 53 I o SD CUkB INLET W/ GRATE \ \RAIL� \I� 1 \ - LOT 54 LOT 55 W I TOP=68787 Gl AVEL WALVONGP LOT 56 (ADU) I I INV IN=680.67 15" HDPE (E) 1\ (ILINDYBAIN LOOP) � �\ \ \� LOT 42 I I _ MHS I INV IN480.82 15" HDPE (SE) - I TOP=685.49 I INV OUT=680.57 15" HDPE (NW) _ I INV OUT=6 7. b4 8'VPV(C (NFI) \ t SPLASH BLOCKS TO BE \ I _ l 1 PLACED AT DOWNSPOUTS ' (TYP) ¢ CMG 8" SAN. SSAIR I / a" CL 52 I 11 \ 1 � LOT 43 WATERLINE GREENWELL LANE ALL AREAS DOWNIAIILL OF S SH BLOCK \ 8" f I / 24'(PRIVATE) R/W g -SAN- -I / DB. 5024, PG. 429 MUST BE STABILIZED IBEFO E ROOF DRAIN S SO CURB INLET W/GRATE I / \ARE PERMI*TED TO 41SCHARgE TO SLOPES I TOP=682.03 v WATERLINE INV 1N=675.03 30" HDPE (SE) SD CURB INLET W/GRATE 2t I DEFLECTION (TYP.) INV OUT=674.30 30" HDPE (NW) TOP=683.93 - , 0 INV 1N=677 63 15" HDPE (NW) Gj INV OUT=67761 15" HDPE (SW) ' \ / FHA Q 4 11 tr 9 8" x 6" TEE Q c SD CURB INLETOP/ 68 73 N LOT 44 8 �.< INV OUT=678.03 15-HDPE(SE) O \ P CON W -��--- �8"x12"TS&V �� o02�y LOT 45 2 `JOA1-v�G--_4-ate \\\ \\\ \ \ �0002G� ; /� MHS \ \8 w� \ i ---- TOP=683.23 r l 6j. Zq ll INV IN=670.03 8" PVC SW h l l /PUB NE 1 I LOT 46 INV OUT=669.93 8" PVC (NE) / �/ j 8 w DB `%70q G� 3 I I \ ` 89 SPLASH BLOCKS TO BE \ \ PLACED AT DOWNSPOUTS \ \ \\ (TYP) \ --- C&G ACSA MANHOLE# OLD-TRL-VIL-23-1. / 1U Q� y0 ry SD CURB INLET \ \ \ TIE INTO EXISTING SSWR / m R / TOP=682.55 \ 48"HDPE \ , J O y /INV \\ \ \ \ NV=671.85 11 \ \ \ ` MANHOLE. CONTRACTOR TO NOTE 4 a a / /z / INV OUT7673580 30'DHDPE (NW) THAT MANHOLE MIGHT NEED TO BE _ V Qj m• REPLACED DUE TO REVISED PIPE / b O O p / / / SO CURB INLET -MHD lANGLE LEAVING THE MANHOLE TOP=682.00 TOPP - -------------------- 1"(6) INV IN=673.70 30" HOPE (SE) INVlN=6771015"HDE(NE)-------- ----------- DECIDOUS INV OUT=673.50 30" HDPE (NW) o-_ - - - - - - - - - ' TREE (TYP) INV 1N=676.55 24" HDPE (SE) INV IN=676.58 15-HDPE(SW) SD CURB INLET INV OUT=676.50 30" HDPE (NW) 1 \ 1 11 I 6„ I 4 1 1 TOP=681.81 I II \ 1 1 I s SO CURB INLET W/ GRATE INV 1N=673.26 30" HDPE (NE) 1 11 I MHD ro TOP=681.03 INV OUT=673.2136" HDPE (NW) It 1 TOP=682.37 I I INV 1N=673.18 36" HDPE (SE) I 1 I INV 1N=672.62 36" HDPE (SE) INV IN=673.63 36" HDPE (SW) SCALE V=20' 0 20' 40' CLINT W. '!i: S FFLET a� • 11/11/21 • 000000*606 M E 0 � o N � N C > E w v E > 2 ~vw3 Lu U. ° 3 t/1 w 0 m ti aLuj V moo Z W OU w -N O > a f�/1ry a U2 30L�x toil �U i a LL Lu j Ln i v ry Z F v Q Cu�Lu as a W V) M 7 W w ul ul 0 x c� 0 0 > o 0 0 co ti Z o� 0 in DATE 0 0412612021 } DRAWN BY J. FOX • DESIGNED BY • J. FOX • CHECKED BY • C. SHIFFLETT SCALE 1"=20' • U 0 W Q z 1 (D W w Q Q Q %' J m J 0 J ~ O j J � ~� U U L.L 0 0 JOB NO. 47652 SHEET NO. C5.0 L \ \ \ � 12" \ \�12"W_ r \ \ 12," W � � � � 03 00 tZl H OL �w I _ W AAAA� m \ 682 TRA& ` ` o (VAR/ABLEW/DTHR/W7 \ \ z 4556, PG. 173 ¢ - -12„ w 6�) 6�� p ` 2 .4038, PG. 681 3' `sg _ - - - - - EX DB. 2886, PG. 704 - - I ro v r ?\ ao 134 \ \ a 683.14' EX \ \ \ 2 +/- 683.00' EX \ I \ \ / / / > ------ ------ -- ----- - - - - - +/- 683.32' EX .v .. /a�'-\ / • a \ ° r. ..,p �. :v .�... ----- +A 683.13' �W J \\ \\ i' // / \ EX \ �h / 688.T //// -_ 'I __ `- -�; .0 •ram 68 \� \\ \ 39;6�lb 6g1 - / EX \ " \ - I /�l'- - - - -682- - - - - \ \ \ - �� +/-683.68' �09 EX ,/ // /I$ 684.34' EX +A 685. 11 • 6'cP EX LOT 39 I_..°' .. .. 6\ +/-68569' \ I ° n \\ r \ EX rn EX am \ FFE: 684.08 LOT 38 \ -- 686.05' I 1 \ \ \ GFE: 681.50 FFE: 684.08 LOT 37 '/ \ , r----- +/- 686.26' EX EX 6ss \ 1 �� LOT 36 - - - �- i - \ ! . .. <j - - - - - - - \+/- 687.43_ +A 688.03' \ \ � GFE:681.50 FFE: / s \ � r - _ ,' -- ---- _ 8 ---- _-- \/ GFE: 681.50 FFE: 684.08 T 35 \ ! _ 6 - - !- GFE: 681.50 FFE1 684.08 > 6--------- !/ GFE: GFE 681.50 684 \ . - - ; °i. > / s / sss.3' 90� LOT 34 FFE: 684.80 LOT 33 f I , GFE:,681.47 FFE: 684.80 L� SOT 31 / - = , 1 11 \ sBa 683 _ GFE: 689.47 FFE: 6 5.80 \ / 1 - - s GFE: 682.47z FFE: 68k.80 / LOT 30 LOT 2 / ` GFE sgs FFE: 686.68 LOT 28 Lp �- l� FFE: 686.Q8 s s6t.2o' f �"' ' GFE 684.34 FFE: 687.68 FFE: 68 8 "9 Tc __ ,I �r i 1 _ 6g? _ - / / / - \ \\ \ - - - - - _ GFE: 685.01, GFE: 686.01 GFE: 686 01\ \ R \ 680.9a'r\�\ / ^ \ 301\ ui ) ^-_ 0 I .s2s 4 p \\\ _679= \,6 .\ 6� S TMP55&01-7A-26 rnE ' \ 68 \ _ // / \ / 8�\ \ \ \s SOUTHERN PROp€RTIESLLC 681 \ _ l / / l I \ \ \ 1 \ \ \ \ \ \ DB. 5071, PG.,231 \ \ � 302 I I 8s� -��_ ! \\�s �I �- _ �•'\-\ it � ii � s / �� > I \ \ ' �, 681- 1 I I TC \ i I \ I \ 300 sso.7s SAN ® \ - --- ` --i SAN _ I\ coVDOT STD\ ' ---- - CLASSII 680.40' I -BROWE I I; -------- \ \\\ \ -----, \ RIPRAP \ 1 WIDTH =9' TC o 307 8'VV I v V AN 1 WIDTH = 29' / - - -� ! I / N - - _\ 1 I \ la I n _astc� _- i�-- i �________ I S - SANt-i _ -+ / \ 1 LENGT 20' \ / 679.81' I - _ ( s - -------- - ! \DEPTH-\g" =i v LOT40 - t - - �>66p - _ 6 8"�/ \\ " --,�/�-----------�--------- j I t-- _ o - 6a m 30 FENNEL ROAD / FFE: 681.50 / / -2. I c> --m - / \ _ \ \ \ \ �(r� 6'�p 1 / GFE:680.05 / 318 , C o II_ __ o ___ _ - 1.�.a _ - - \ - - - 6; -18„�� 310 VAR/AB¢EWIDTH / VARIABLE WIDTH N Z M / / 679.90' s7s.1�' o T 1� ___ate - sa - SWM FACILITY EASEMENT ` O / I °' O NMI y.11 \ - ' _ ¢ (PRIVATE) R/W / y / 679.79' o i i -- - - - -- O--------------- m - - -682 1 / 316 TC 1 I \ I " / nI \ _ \ _ _ i 679.64' \ \ / I _ O I I IL ------_-------- I \ 1 1 A LOT 41 1 \ \ \ \ FFE: 681,05 -3'2 - z ° ` LOT 47 (ADUI I \\ \ I GFE: 680.50 FFE: 681.90 LOT 48 1 GFE: 680.40 �F / LOT 50 682.90 LOT 49 / s79sr GFE. 681.40 FFF: 682.90 FF 83.90 LOT 51 (ADU) 679.78' - ' 'GFE: 682.40 FFE: 683.90 z� -GFE: 681.40 u LOT 52 (A \ I 1 11 \\\ \ \ I \ GFE: 682.40 FFE: 686' LOT 53 GFE:484.05 FFE: 685.55 LOT 54 I LOT 55 1 1 GFE: 684.05 FFE: 68§.&5� FFE: 687.55 LOT 56 (ADU) 1 I LOT 42 GF;<:884.69 GFE: 686.05 FFE: 687.55 FFE: 681.50 °� \ 682 I / _ _ GFE:686.05 1 GFE: 680.50 \ 680.06' 680 \ 6g3 r , - ' r / - - - - - - -6861 \ \\ \ \ \ \ 67ss7' \\ A 68S 687 - 686 v LOT 43 ` 1 0 0�°2 GREENWELL LANE FFE: 681.54 \\ 291 b O>y�q�\\ L \ \ ds�s a - 24' (PRIVATE) R/W 1 11 I GFE: 680.5q ssosaa.a5' �6S A F .d .01 \ $� sAN- \ I 1 I \ \ \ \ -" DB. 5024 PG. 429 \ 1 \ 681 Pq 681 680.90' d 7 \\ �2g \ _ I W 680.80' 0 � 68 TQ W C9 ab w 4 In I�------------s&0\ I ° O NO LOT 44 (ADU) \ d I FFE: 683.50 100 a \ \ GFE: 682.00 \ stso ° \ \\ \i I\ 82.02' 6B3 \ " / b 682.7' \ .=~c---- TC `\ \ \ \ \ E' �1 a .. S \ 682.65' 3 / I \ - _- - - b _ \ od, I 684.3' LOT 45 �0�o� \ 1 \\ FFE:683.50 GFE:682.00 \\ ;, d / ---� `683'--__ tp RX ow Z4,v 684- - I-t LOT 46 (ADU) / \l UBG/C E I I FFE: 683.50 / / - l / 8" \ \ B. 41pq PG R/rY I GFE:682.00 389 \\ IO M \ J / \ 0 v /Q n I 494 rA \ I -- - - - - ----- '/ 1 CI l I DUOUS ;---------1 / /-------_ - -- ; ---_- - - - - - - I - �REE(TYP) I 11 II 11 S I 1, I 1 I I SCALE V=20' 0 20' 40' CLINT W. '!i: S FFLET a� • Lit. Nfr54380 49* 11/11/21 • ��ti'b0���N� �,� M E 0 o N � N C > E w v E vw a; 2 ~3 Lu U. w0 mti I_ � I i52 Z W OU w -N O Z > Lww ry rn I� a(/1 a U 2 zF �x V �U i a LL wp j ur) v ry Z F�< =rn as a Mo W7 00 J Lu Lu M 0 x (7 0 0 w o0 Lu a o �� Z o� 0 in DATE 0 0412612021 } DRAWN BY J. FOX • DESIGNED BY • J. FOX • CHECKED BY • C. SHIFFLETT SCALE 1"=20' U O Z J Q Q Z W Lu iLLI 7Q E2 Q co J Q 06 LL ~� O Z Z J =) p z < ° Q U 0 M L.L O JOB NO. 47652 SHEET NO. C6.0 L LTH rr, \-12"W � � � pr `fir, 6 A - a \ \ I cl 6a2 - \ \ -�/y S FFLET a .- O 1'RA/LOR/VE --- >2'W� �o��ocy' (VAR/ABLE WIDTH R/W \ \ - Q "w v dv A Oo O • J \ h �12„W_ U NOTE: •Ak DB. 4558, PG, 173 _ _ AL BEhrT��EBUN�GIS 4� 4� 4� ` Z L Lit. N . S�Sde 4vv ssz DB• 4038, PG. 704 g I MANAGED STEEP SLOPES (TYP) v V v v v ~ EXISTING STORM INLETS AND DRAINAGE VALUES WERE OBTAINED 7riL,,�� 111 II/ 21 ��'. EX DB, 2886, PG. 134 _ - ' 6a \ \ �' `D `D r FROM APPROVED OLD TRAIL BLOCK 7 PHASE 2 ROAD & UTILITY r,�'rS l�G��� 683.14' EX \ \\ \ a rr TONAL t �� \ PLAN (SUB201800012). CALCULATIONS WERE PROVIDED FOR THE rh0000*0 04 +/- 683.00' EX \ \ \ 11 / ---- --- +/- 683.32' ` \ \ SSA m NEW STORM SYSTEM THAT NOW CONVEYS STORMWATER FROM Ex s� a ' , EXISTING STRUCTURES 8, 9, & 19 TO THE SWM FACILITY L-1. LEGEND 683.13' w � \ \ � / 682.9' \� EX \ 688.7' 6S \� - \ +/-683.39; \ \ /6 0g� o 0 EX \ \ / 6� , 0 Qr - AREA G N 7/_ - - - -682- - - - - \ 683.68' s ' 6`3 y09 ¢ o EX \ / ' / ' > 684.34' EX / / / 1 STR # eE +/-685. 11' 6'w EX \ / / 1 = _ r' p1 _ I- I \\ \\ +/-685.69' EX aca \ 1 H_ w w 3 W ` 1 \ __ a EX w \ TIME OF CONCENTRATION H_ 3 i \ \ \ - = +/- 686.26' EX EX 6a>s \ w O `m ,�-i z SQ. FT. 1719 _ _ _ _ \ / C� ------ LL \+/-68743' +/-688.03' \ SQ. FT. 1726 / S \ ' 11_ I 6� �8 - - ---- ---- \ \ a W z W SQ. FT. 1721 ` -1-L 6g6 w w -iri O > . _ _ 83 - - - - _ SQ. FT. 2084 6 \ \ �- _ _ _ / - - a o N I 0.08 0.90 l - -- --- --SQ. FT. / -�11 _1_� //I I /i' i / sss.3' 69�^ zf iM V= 302 2021 1629 / \ -I-1- �1_L & ai LL p ESQ. FT. \ ' o c = v O v\ �� / SQ. FT. - 1618 \ \ ) / ENCHMA / 1 0.22 0.95 Ln x v ry z U ` ` - / k NAIL IN SWLix ix . - - - - 0.29 0.80 / i _ S20 FT. 6 L \ \ v to \ Tc I / / - \ - \ 66 2135 2135 LEV= �640' rn s� EX. 19 ° ry > d d SQ. FT\ SQ. FT: _ -SQ. FT. 2084 9 \ w v � W W 304 SQ. �t\�- \ ■■■ ■■�■■ ■�■■■ ■■■■■ - Tc=6MIN w� SS \ 301 \ (------- I i _ I I I 4 p\ \ \ \--s79-- ` \ S - TMP 55E 01-7A-26 �o w ul ul 40 All I \\ \ \ ■ vi ,I 680 �sSB� - i __J--�-- I I 0.29 0.84 ■ I 300 I II ■ -ire 303// s7s.s�' -_ \ '6 ' •' ` ------ - ( 1 ; I \ i 312 ■ 0 VDOT STD I SAN �■ 4 N N 1 ■ __ 1 \ \ - Tc=6MIN ♦ w NN ���� \ _ \ o / I \ \ CLASSII \ ` u 0 N \ \ Lu BROWtSSTONE I II ■ / � 306 � _ - �■�'■�■- - - ` � I \ - - � RIPRAP� WIDTH -9' I ■ //� \ / 307 ,\\---��\,_ �■■ \ I -sa\ aNt-- -_� S zz 0� WIDTH =29• , ■ / 1 -/ /� I 3111�■ l / -SAN--I ` 3 1 ♦ v1 DATE LENGT\= 20' / - _ I t 6 E■ ■ / - SAN+ - - \DEPTH =\9„ \ I ■ -------- - - w�,sgo ` - , _ rn \ \ vt ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ `■ ■ 1 ♦ 0309 04/26/2021 4*2 / / - --- - 1 / - _ - - \ \ s� �60'6 �- 310 1 DRAWN BY VARIABLE WIDTH \ \ I Z m SQ.tT. / / 318 o n-------- - �1 -------- 68� - - 6 - - - � - N _ _ bw VAR/AB4E WIDTH \ o D / o I I 1 - - - _ - ¢ (PR/VATE)RNV r - J. FOX SWM FACILITY EASEMENT ` I v ■ o -- - - r / l - i DB. 5074, IPG. 2341C 11 / m D �1 \`.i ■ / \ \ I I I --- - - • DESIGNED BY _ 682 I- - \ ---- -- - - ------ \ ■ ■ I rn A c000 316 1� / , 1 • 0.09 0.95 • J. FOX > 1 m ■ \ 0 - _ _ 0.20 0.87 % : ii I : i ` - ' - : • CHECKED BY DO 1 \\ 1\ \ 11 3 ■ \ ` I / ■ �' 308 ' ■ II ■ I ■ EX. 8 • C. SHIFFLETT 1\ \ \ SC ■ 2445 s / 1 / ' • SCALE ' \ \ ■ 2 SQ. FT. ° 1738 1735 1 % T 6 MIN I Tc = 6 MIN SQ. FT - SQ. FT. 2203 / 1732 c ■ ■ ■z ■ 1 " = 20' \ \ ■ - ESQ. FT. 5 _ -0 NMI 11 \ \\ '` �I\ i ■ o - `\ 1 SQ. FT. i 2145 '6 I ■ ■ I I \ \ \ , G� / ■ SQ. FT. 1732 I c ■ / / \ - ` -' ; - _ SQ. FT. 1732 1730 ■ ■ I ■ `\ \\\ ` II \ _ \- ■■ 1 / SQ. FT. SQ. FT. Q F-9 682 � � I � i- � SQ. Fl� 11 ■ � II i 03307 `0 \ I 683 f ( 1 I _680 NJ 1\\y 1\ '\I �1 ` \\ I'V ■ 0.56 0.64 ♦ �� i /' \ _ _ , ■ 0.08 0.95 GREIENWELL LANE (, 5549 \ \ \ ♦ F- \ 1 \ \ I 316 \ -sas ■ EX. 2116 I / / / DB( 5024, PG. 4I SQ. FT.■ b \ \ ♦ \' \ I 1 I ■ \ S 1 Tc=6MIN ■ ■ v 1 I i ■ \ I . \ \ 681 ass 681 ` z rn ■ ■ Tc = 6 MIN U II II ; "-- i 0.49 ��/'� 318 \�\ 11\/: \\ 0.36 0.65 f 68 Q �y W Z Lwrinj 1 ` o . \ EX. 215 ■ Q Tc=6MIN � z \ \\ \\\ \\ \ \ 1��' \ \ ♦ 11"----- Tc=6MIN ■ Q �� w IL Q \ \ LJ_ 1*33 \ I ■ ■ Q gSQ LLJ 0 �(D \\\ A�/,il\♦♦ \\�•.$3 . 1\ `"''*'L,� 682.i \ \ s �.-� . ■ J Q W \ ��� , 1 \ ♦ ♦1 \ - - •mayArt& ; , ___-______ I _ ♦ J tp \ \ \ oo G to \ \ , u� cv ■ s„ - / /- • �/ I I - �k- ` f -- -- - ♦ ■ ■■■■��of �••�D4~NE 684--- 11 ♦♦ U) SQ. 5. m �/ 8W\`=�G389 r��•■■■■■�■■■■■■■■■■■■■■■■■■■■■■■■� `\ '\ \ r I r' � ♦ �� / 2 f.p_y ,° , dry. -� Q/ ��' -B,•W- /Q / -------------------------------------------- ----- -- r---- 'DECIDUOUS Il[7 \` --------------- - o-_ v\ JOB NO. II O SCALE 1"=20' 47652 1\ II \1 I I I ' SHEET NO. 1 I I i i 0 z0' aoC6.1 L ca M M rn ��ALTH 6; 0qoCm r` a ��' �C,Z M+moms CLINT W. N ^ r • cr- .. o o a� 0 i m 0 316: DI-3C 8 ft Throat t�/7 S F F L ET i M M_ • E $ O z z u° P M t o STA 10+26.68co L • o ~ rn TOP 679.68 Lit. N 543dd �4: O oNM CO °°Do. NN°'� vo 00 INV IN 673.56(317) 11/11/21 ��'� oo� Q��nMM m 00°�o�"O`O `O INV OUT673.36 315 • S G • W0 ED �D�Z =N°^'mmH M�jaO(O(Oj ( ) i%#0!1AL���� O 2�(DzZ� ��coZZO tib�H°�N M (nOZ MU)P Z C:, Z M�Z Z Z 695 f° rn ~ - - 695 306: MH-1 STA 10+00.19 Mo E TOP 679.47 318: DI-3C 8 ft Throat N INV IN 673.23 (315) STA 10+61.75 E INV IN 673.23 (307) TOP 679.67 INV OUT 673.03 (305) INV OUT 673.73 (317 = E 690 �90 H_ U w 3 2 LL 3 Lu w 0 m ¢_j UOMO Z W OU w -in O > a f�/1 rv'm a U 2 zF x U �U a LL p j i v ry Z 00 F�< =rn � as av W M 7 W J �� O x c� 0 w o0 w Lu = a o� 0 �" Z oti O in DATE 0412612021 0 DRAWN BY J. FOX 9+50 ,°+°° "+°° 12+00 STR 3003+0STR 310 14+00 15+00 16+00 16+50 9+50 STR 306 -STR 318 „+50 •• DESIGNED BY HORIZ SCALE: 1"=50' HORIZ SCALE: 1"=50' • VERT SCALE: 1"=5 VERT SCALE: 1"=5 CHECKED BY • C. SHIFFLE7T SCALE • H: 1 " = 50' V:1"=5' • • ca am o rn 0 F M M � V o O O r m o r-. �o m co 0 oM }� ED j �oZZO U M�OZZZ 2 U t O mo�(0 J -Q+p�0 Q NFOO z vl Z 690 " O ~ - 690 I J U--� LL; LL Q Q BUSTING J m J Q 8" WATER t-� O 0 CROS }} Z J z < I� O U L.L 0 0 J O 9+50 10+00 11+00 11+50 STR 308 - STR 312 HORIZ SCALE: 1"=50' VERT SCALE: 1"=5 JOB NO. 47652 SHEET NO. C7.0 690 690 ISTING GRADE PROPOSE GRADE i 685 685 WATEMAINROSSI G � 48" 680 680 3.5 / / 2.8' 9 F O 125 NAPE 675 2.4' 675 O 307 pE 132.16� 03 � 2.02 /O 301 143. 0' OF 670 670 24" HDPE � '50 ° 30 0.5 % 28.81' O 24" HDPE: 0.50° 8" SANITARY SEWER 665 CROSSINGS 665 PROPOSED GRADE 685 685 GRADE AIN ING 3� 3 5' 680 680 1' 675 311 675 1. 15" HDPE 6.50% 8" SANITARY SEWER CROSSING 670 670 EXISTING GRADE 685 685 PROPOSED GRADE 680 680 3.8' 675 675 1.5' 317 670 315 34.92' OF 670 15" HDPE 'HDPE � 0.50°k 0.50% 8" WATERM IN CROSSING 665 665 STORM PIPE TABLE PIPE # DIA FROM -TO UPSTREAM INVERT DOWNSTREAM INVERT SLOPE LENGTH DESCRIPTION 301 24" 302 - 300 671.77 671.37 0.50% 79.57 LF 24" HDPE 303 24" 304 - 302 672.69 671.97 0.50% 143.50 LF 24" HDPE 305 24" 306 - 304 673.03 672.89 0.50% 28.81 LF 24" HDPE 307 15" 308-306 675.90 673.23 2.02°k 132.16 LF 15" HDPE 309 15" 310-308 680.15 676.00 3.31 % 125.47 LF 15" HDPE 311 15" 312 - 308 678.00 676.00 6.50% 30.77 LF 15" HDPE 315 18" 316-306 673.36 673.23 0.50% 26.52 LF 18" HDPE 317 15" 318-316 673.73 673.56 0.50% 34.92 LF 15" HDPE EX. 8-310 15" EX. 8 - 310 680.57 680.25 0.61 % 52.25 LF 15" HDPE EX. 9-8 15" EX. 9 - EX. 8 681.45 680.82 0.74% 85.64 LF 15" HDPE EX. 19-8 15" EX. 19 - EX. 8 681.54 680.67 2.38% 36.57 LF 15" HDPE STORM STRUCTURE TABLE STRUCTURE # TOP STRUCTURE HEIGHT DESCRIPTION 300 674.62 ES-1 for 36 inch Pipe 302 681.16 9.39' DI-3A 304 679.70 7.01' DI-3C 8 ft Throat 306 679.47 6.44' MH-1 308 682.71 6.93' DI-3B 4 ft Throat 310 681.71 1.56' MH-1 312 682.85 4.85' DI-3B 4 ft Throat 316 679.68 6.32' DI-3C 8 ft Throat 318 679.67 5.94' DI-3C 8 ft Throat EX. 8 687.87 8.79' DI-2B 6 ft Throat EX. 9 688.90 9.45' DI-2B 4 ft Throat EX. 19 688.90 9.36' DI-2B 8 ft Throat L *,NLTH of CLINT W. S FFLET aZ �L Lit. N 54380 �4Air v S� 11/11/21ON At • M E 0 0 u N � N 0 > E STA 12+70.84 ' _ E STA 10+00.00 "Ex" STA 11+54.7g STA 12+70.84 ' TOP ,) � w m 3 TOP 683.23 f 4-' TOP 680.12 3 TO X INV IN 668.48 (2-1) ¢ . � 3 W INV OUT 669.93 (Ex4-3) INV IN 668.80 (Ex4-3) INV IN 668.48 (2-1) STA 10+00.28 2 /NV IN 66790 (3-1) w O `6 ^� z TOP 681.15 INV OUT 668.60 (3-1) INV IN 667.90 (3-1) INV OUT 671.64 (2-1) INV IN 668.48 (ex pipe) a � � o z w 685 INV IN 668.48 (ex pipe) 685 685 685 > o m atnry a O2 zF �x V �U a LL p j � i v ry z FUa'm ix ix 0 mLu .�. d d a� W � M 7 W J Lu Lu �� �� vi 0 m c� 0 W o0 w = a O� ti U o �� Z o� 0 (n DATE 0412612021 0 } DRAWN BY J. FOX • DESIGNED BY • J. FOX • CHECKED BY • C. SHIFFLETT SCALE • H: 1 " = 50' V:1"=5' 9+50 10+00 11+00 12+00 13+00 13+50 9+50 10+00 11+00 12+00 12+50 SANITARY STR EX4 - EX1 SANITARY STR 5-2 • HORIZ SCALE: 1 "=50' HORIZ SCALE: V=50' • VERT SCALE: 1"=5 VERT SCALE: 1"=5 690 690 U 685 685 j U _z 8" CLASS 52 DUCTILE O IRON WATERLINE M� W Q Z 1 (D LJ J > J_ W w L.L (3 � O Q Q m a J Q LL ~ }U} J Z LL J 00 > i--i U ��// U Ul L.L 00 Cj O 9+50 10+00 11+00 12+00 13+00 13+50 9+50 10+00 11+00 12+00 13+00 14+00 15+00 15+50 - ORION LANE WATERLINE FENNEL ROAD WATERLINE JOB NO. HORIZ SCALE: 1"=50' HORIZ SCALE: 1"=50' VERT SCALE: 1"=5 VERT SCALE: 1"=5 47652 SHEET NO. C7.1 Lu 680 II 680 EXISTING PROPOSED II 8"W TERLINE 675 GRADE GRADE CROSSING 675 5" STORM ROSSING670 670 Ex4-3 154.79' OF 3_1 EXISTING GRADE 680 680 PROPOSED GRADE 675 675 8" CLASS 52 DUCTILE e IR N WATERLINE 18" STORM CROSSING 670 670 8" SANITAR SEWER 665 CROSSING z 665 H z O w w w z� Z J W a sso w � W z = sso aa0 �w � % Z W J OZ W LLI J 00 J J a ww 655 � w w� � a u~i z 655 EXISTING GRADE i PROPOSED GRADE 680 680 8"WA ERLINE CROSSING 675 675 Vt�1 "STORM CIIOSSING 670 �- 670 1577g�OF �2po�6 u 665 665 660 660 655 655 PROPOSED 685 EXISTING GRADE / 685 GRADE 680 680 3 2.8' 1 675 1 675 BEND WATERLINE 15" STORM AS NEEDED O ACHIEVE CROSSI G 24" STORM CLEARANCE CROSSING 670 15" STORM 670 CROSSING z � w z O F 665 � z 665 8" ANITARY O > SEWER � w w � CROSSINGS Q zo � J J � 0 sso W� W Z � m w � sso � > � m N m m � � � � LL O � Q' � w a0 O O O FO o � cv Co � N � 655 � � � 8o N v a co H 655 L LOW POINT STA = 11+29.49 LOW POINT ELEV = 680.83 PVI STA = 11+70 PVI ELEV = 680.22 A.D. = 4.14% K = 38.66 160' VC o uI) orn 690 o ro HIGH PT STA = 14+05.63 HIGH POINT ELEV = 687.31 PVI STA= 13+65.63 PVI ELEV = 686.32 A.D. = -0.62% K = 129.12 80' VC OO (O G' 4u) uir +coo oa II � II u LU u ° � II II �w (a 0_ 685 685 312°b � 680 680 675 675 670 670 p� N� ^a N� No N°) No �03 N p� c\iN N r MO hLO N� r:r. CD 0 9+50 10+00 11+00 14+00 FENNEL ROAD (PRIVATE R/W) HORIZ SCALE: 1"=50' VERT SCALE: 1"=5 ORION LANE FINAL Number Length Radius Line/Chord Direction A Value C5 231.700 200.000 N210 36' 05.64"E L6 25.046 N540 47' 24.76"E L7 62.788 N 110 35' 13.47"W FENNEL ROAD FINAL Number Length Radius Line/Chord Direction A Value C1 42.871 35.000 S150 28' 56.67"W C2 200.573 5935.367 S21 ° 14' 25.89"E C3 10.868 990.000 S220 06' 28.52"E C4 38.158 510.000 S25° 00' 53.27"E L8 39.095 S270 09' 29.58"E L9 52.576 S220 52' 16.96"E L10 34.195 S190 36' 29.60"E 1-111 11.774 S500 34' 22.93"W -1 G �? y 4282 o p Am SQ. FT. N Z D O � t m _egg 00 Im z co \ A ( 3122 \ SQ. FT. 1� I ! M � I 3307 0 \ SO. FT. 1 � i 1 ! 1 5549 \ I SQ. FT. 1 I � 1 1 \ II i 682_ I 1 I \ \ \ 1 \ \ i 1N1 5333 \ \ o\ \ 6a1 \ SQ. FT. \ / 1 \ \ 1 I 3976 SQ. FT. 6835 SQ. FT. HIGH PT STA = 10+30.45 HIGH POINT ELEV = 682.95 PVI STA = 10+50 PVI ELEV = 682.78 A.D. _ -0.71% K = 54.68 39' VC 'tO) to It O N O N + (00 c° o + co II U II U U)m U)w 695 m w LOW POINT STA = 12+50.58 LOW POINT ELEV = 680.01 PVI STA = 12+50 PVI ELEV = 679.63 A.D. = 3.11% K = 31.24 — 97' VC A n Q) cn 00 a) X) 0) O a + m n C 11 jII U rn n �w w 695 O N o OCO c') 690 II 690 aw FJ Lll GOO+ Om (00 EL I>nw a II Ww J W 685 —> > 685 a -1.57% 680 1 /G % 680 675 675 670 670 MGo °'iN M� N� NO It NO NO 00 15+00 15+50 9+50 10+00 11+00 12+00 13+00 ORION LANE EXTENDED (PUBLIC R/W HORIZ SCALE: 1 "=50' VERT SCALE: 1 "=5 VAR/AB, EWIDTH /P TEI R/W w .. .. _..".. .. �D .5074, IPG. 234C =1- M SQ. _ SQ. SQ. SQ. T. 2145 6a 173 SQ_ 1732 � I i SQ. FT 1732 J SQ. F SQ. F 201 SQ. F . III I I 0 a 687 I P — _684 — -686 686 --' I — — — GREE 24 \ I 681 1 ° � ON, — W gggg— — — — — — 00 I Oam 684.3' tp P&a 4 PG- S � � ,y � 6� 14+00 14+50 CLINT W. '!i : S FFLET az • Lit. N 54380 4'o 11/11/21 • I•~'O 4,0* 6 06% M E 0 0 U N � N Q O > E w a E �y 2 H- U LL o 3 w 0 m �_j U00 Z W �U w —Li O > a f�/) rv� a U 2 ZF'x U �U -i a LL LU j U-) i v ry Z O 0 rn .U)w LU . d d M 7 o > j M 0 x U 0 0 x 0 N N w O O w = a O ti U co Z O 0 (I) DATE 0412612021 0 } DRAWN BY J. FOX • DESIGNED BY • J. FOX • CHECKED BY • C. SHIFFLE7T SCALE • H: 1 " = 50' V:1"=5' U 0 U O W Q z ' ^ v J W w > J_ P'1 Vw 0 J Q < J w a m ~� LL O Q O J z I� O LL M O JOB NO. 47652 SHEET NO. CV.O m 0 3 c a 9X o �Z .2O c mw a c m a- O O 3 U3 Z„ O � a F � o �3 n dm 2 Y � N X C do m h m C .12. O N O E C dM 06 a c �a 10 a 0 � O m a c m �o c � m nE L F E L *,NLTH Oi PROJECT OLD TRAIL BLOCK 7C DESIGNER: JLF DATE 11/3/2021CLINT W. CHECKED: C. Shifflett UNITS ENGLISH ? S FFLET i • •L � Lit. N 54380 ��4'� S� 11/11/21 11 'cis G �.ONA M E 0 O MU N N C > E w ai E >y 2 � U a) LL o 3 Lu w 0 m ¢_j UOM0 Z W OU rum-n O Z> .. M I� ( n LU a U 2 z0x U�U � � 6u- p jc. i u ry Z O 0 rn .�. d d a � W M LU 7 W J Lu Lu V] I- � vi O x (7 O x F 0 N N w O O w _ ~¢ o U �� Z o� O ul DATE 0412612021 O } DRAWN BY J. FOX • DESIGNED BY • J. FOX • CHECKED BY • C. SHIFFLETT SCALE N.A am U PROJECT: Old Trail Block 7C Designed by: J. Fox PROJECT: Old Trail Block 7C DESIGNED BY: J. Fox STORM SEWER DESIGN COMPUTATIONS LOCATION: Old Trail Village HYDRAULIC GRADE LINE ANALYSIS 0 COUNTY: Albemarle Checked by: C. Shifflett Checked: C. Shifflett z STORM FREQUENCY 10 INCIDENCE PROBABILITY 10 Year J 0 CO UNITS ENGLISH Q Q ce Z J W '. U LL J 0 (D c2 Q Q L U J m � J a W i--i o < a J �� U U Q 0 312 677.35 15 2.17 30.77 0.10% 0.03 9.86 0.38 0 0 0 0 0 0 0 0.38 0.49 TRUE 0.27 677.63 682.84 OK -5.21 EX 9 681.82 15 0.25 85.64 0.00% 0 2.43 0.02 0 0 0 0 0 0 0 0.02 0.03 FALSE 0.03 681.85 688.9 OK -7.05 J 0 JOB NO. 47652 SHEET NO. C9.1 DRAIN. RUNOFF CA TOTAL RAIN RUNOFF INVERT ELEVATIONS LENGTH U) > 311 312 308 0.290 0.840 0.244 0.244 0.000 0.000 8.901 2.168 678.000 676.000 30.772 0.065 15.000 Circular INLET d Q U d U U � w U � � aa� > r?aLU W vi CdJ� �, aU pU30 � `�� Oac4 `�� v �`F" F.Hw.. ri � o �w• v p�� O W �� F m rn wvi P.' a >?V a ` Sag Inlets Only � z m aw_ w� � d 302 DI-3A 2.000 0.080 0.90 0.072 Back/Lt. 0.000'RIGFLC 0.072 4 0.288 0 0.001 0.0208 4.362 2.000 0.45851 0.0833 4.00481 3.50 Back/Lt. 0 4 0 0 Ahead/Rt. 0.288 0.001 2 0.288 0.951 0.125 0.333 0.375375 2.951 3.811 Weir Flow 304 DI-3C 8.000 0.247 0.90 0.2223 Back/Lt. 0.000'RICdI 0.043 0.25 0.01075 Back/Lt. 0.233 4 0.932 0.252 0.001 0.0208 9.660 2.000 0.20704 0.0833 4.00481 3.50 Back/Lt. 0 4 0 0 Ahead/Rt. 1.184 0.001 8 1.184 1.503 0.125 0.333 0.375375 3.503 6.020 T > 6.0 ft 308 DI-3B 4.000 0.190 0.90 0.171 0.000'RI(i£i 0.010 0.25 0.0025 0.174 4 0.696 0 0.696 0.0200 0.0208 2.398 2.000 0.83403 0.0833 4.00481 0.999 3.50 0.1458 0.1665 6.327 4.000 0.632 0.835 0.581 0.115 2.099 312 DI-3B 4.000 0.222 0.90 0.1998 O'RI(�IT 0.068 0.25 0.017 0.217 4 0.868 0 O.S6S 0.0200 0.0208 3.091 2.000 0.64704 0.0833 4.00481 0.986 3.50 0.1458 0.1646 6.988 4.000 0.572 0.783 0.680 0.188 2.271 316 DI-3C 8.000 0.332 0.90 0.2988 Back/IA. 0.000'RI 0.228 0.25 0.057 Back/IA. 0.356 4 1.424 0 0.0100 0.0208 5.571 2.000 0.34066 0.0833 4.00481 3.50 Bacic/Lt. 0 4 0 0.115 Ahead/Rt. 1.539 0.0100 8 1.539 1.790 0.156 0.500 0.312 3.790 7.171 Weir Flow 318 DI-3C 8.000 0.440 0.90 0.396 Back/Lt. 0.000'RI 0.048 Q25 0.012 Back/Lt. 0.408 4 1.632 0 0.0100 0.0208 6.355 2.000 0.31471 0.0833 4.00481 3.50 Back/IA. 0 4 0 0 Ahead/Rt. 1.632 0.0100 8 1.632 1.861 0.156 0.500 0.31? 3.861 7.d�7 Weir Flow EX 8 DI-2B 6 0.090 0.90 0.081 O'RIGFIT' 0.081 4 0.324 0 0.324 0.0150 0.0208 l.(i64 2.000 1.20192 0.0833 4.00481 1.000 3.50 0.1458 0.1666 4207 6.000 1.426 1.000 0.324 0.000 L664 E}L 9 DI-2B 4 0.030 0.90 0.027 O'RIGFIT' 0.027 4 0.108 0 0.108 0.0150 0.0208 1.103 2.000 1.81324 0.0833 4.00481 1.000 3.50 0.1458 0.1666 2.652 4.000 1.508 1.000 0.108 0.000 1.103 EX.19 DI-2B 8 0.220 0.90 0.198 O'RIQI'T 0.198 4 0.792 0 0.792 0.0150 0.0208 3.257 2.000 0.61406 0.0833 4.00481 0.981 3.50 0.1458 0.1639 6.186 8.000 1.293 1.000 0.792 0.000 2.313 PIPE NO FROM POINT TO POINT AREA "A" Acre (3) COEFF. "C" (4) INLET TIME Minutes (7) FALL In/Hr (8) Q CFS (9) of Pipe Ft. (12) SLOPE Ft./Ft. (13) SIZE (Dia. Or Sp an/Rise) In. (14) SHAPE Capacity CFS (15) Friction Slope Ft./Ft. VEL Vn Ft/Sec (16) FLOW TIME Min. (17) REMARKS (18) INCRE-ACCUM MENT (5) ULATID (6) ADDTL CA UPPER END (10) LOWER END (11) REFERENCE (1) STA. REFERENCE (2) STA. EX.19-8 EX.19 EX.B 0.222 0.950 0.211 0.211 0.000 0.000 8.901 1.877 681.540 680.670 36.575 0.024 15.000 Circular ]0.790 0.001 6.612 0.092 EX. 9-8 EX.9 EX.B 0.030 0.950 0.029 0.029 0.000 0.000 8.901 0.264 681.450 680.820 85.639 0.007 15.000 Circular 6.001 0.000 2.429 0.588 EX. 8-310 EX.B 310 0.090 0.950 0.086 0.325 0.000 0.588 8.522 2.769 680.570 680.250 52.254 0.006 15.000 Circular 5.475 0.002 4.484 0.194 309 310 308 0.000 0.000 0.000 0.325 0.000 0.782 8.405 2.731 680.150 676.000 125.467 0.033 15.000 Circular 12.724 0.002 8.276 0.253 INLET OR JUNCTION INLET STATION OUTLET WATER SURFACE ELEV. DIA. PIPE Do (In) DESIGN DISCH. Cto (CFS) LENGTH PIPE Lo (Ft) FRICTION SLOPE', Sfo (FT/F� FRICTION LOSS Hf (Ft) JUNCTION LOSS FINAL H (Ft) Inlet Water Surface 9evation Rim Bev Comments Vo Ho (Ft) Qi Vi QYi Vi*2/2g Hi Angle FIO Fit 1.3 Ht 0.5 Ht 302 672.97 24 14.29 79.57 0.34% 0.27 6.18 0.15 14.08 6.16 86.72 0.59 0.21 20.19 0.15 0.5 0 TRUE 0.52 673.49 681.02 OK -7.52 304 673.57 24 14.08 143.5 0.33% 0.47 6.16 0.15 12.27 6 73.59 0.56 0.2 89.44 0.39 0.73 0 TRUE 0.84 674.41 679.7 OK -5.28 306 674.49 24 12.27 28.81 0.25% 0.07 6 0.14 6.13 8.54 52.39 1.13 0.4 88.71 0.79 1.33 0 TRUE 0.74 675.23 679.47 OK -4.25 308 675.23 15 6.13 132.16 0.77% 1.01 8.54 0.28 2.73 8.28 22.6 1.06 0.37 91.29 1.06 1.71 2.23 TRUE 2.13 677.35 682.71 OK -5.35 310 677.35 15 2.73 125.47 ° 0.15/0 0.19 8.28 0.27 2.77 4.48 12.42 0.31 0.11 0 0 0.38 0 TRUE 0.38 677.73 681.71 OK -3.98 EX 8 681.25 15 2.77 52.25 0.16% 0.08 4.48 0.08 1.88 6.61 12.41 0.68 0.24 57.1 0.38 0.7 0.9 TRUE 0.53 681.78 687.87 OK -6.09 EX 19 681.78 15 1.88 36.57 0.07% 0.03 6.61 0.17 0 0 0 0 0 0 0 0.17 0.22 TRUE 0.14 681.92 688.9 OK -6.98 316 675.23 18 6.79 26.52 0.36% 0.09 5.12 0.1 3.66 4.42 16.21 0.3 0.11 64.87 0.17 0.38 0.49 TRUE 0.34 675.57 679.68 OK -4.11 318 675.57 15 3.66 34.92 0.27% 0.1 4.42 0.08 0 0 0 0 0 0 0 0.08 0.1 TRUE 0.15 675.71 679.67 OK -3.96 L -\ --- OLD �- - - 72••`"� o 0 0 0 0 _682 - 7"RAQD -- ��—>z-W� �oNu�� th RIVE a�oc3 (VARIABLE WIDTH R/W� v W v N a O �12"W— U U \ OB. 4556, PG. 173 - ALBEhTTR EBfJAIFXGIS 6) p !z 4� Z eel\ co / \-----682 L see , \ I, I ` I ( I ( I I VDOT STD1 I - - CLASSII BROWNSTONE RIPRAPI WIDTH = 9'' WIDTH = 29' LENGT \ 20'\ DEPTH =v9" 428 1 \ VARIABLE WIDTH 1 SQ. SWM FACILITY EASEMENT i A \ iii 1 1 I \ I \ ( 1 \ I \ V. \ 1 \ \ I i \ 1 1 \ 1 I \ I I V I I V I I \ I I \I \ I \ \ 1 \ \ 1 rn� \ \ I \ 1 \ \ 1 I \� 1 \ 1 1 I 1 1 1 I I 1 I I 1 (\ I 1 ( I 1 I I 1 I ' 1 PLANT SCHEDULE TREES BOTANICAL NAME ACE OGL ACER RUBRUM 'OCTOBER GLORY' BET CIM BETULA NIGRA'CULLY IMPROVED' TM QUE PAL QUERCUS PALUSTRIS QUE PHE QUERCUS PHELLOS CLINT W. �: jw� ?S FFLET a� Lit. N s43ee tar. 04/ 26121 ��� OB. 4038, PG. 704 6g3, ' ' MANAGED STEEP SLOPES (TYP) ,V V v � � � � ��SS �G,•� +/ 68DB. 2886, PG. 934 _ - _ elf O �' N �� � EX - EX � � ---y_ oo +/-683.00' E r- 683.32' EX (2) QUE PAL 68a , Rl + - 683,13" w EX V } 68 \ +/- 683.39' /6 �6 6�� o 1_ - i ti 683.68'syQ EX \ ' (1) BET CIM r (4) ACE OGL i ��� 6�9 ^ c > E EX E EX 1 +/- 686.05' EX w� \ I Q LL T, 3 EX lu 2166 - 1 - >' SQ. FT. 1719 ' 6 +/- ss.26' EX 6 0 ° SQ. FT. 1726 - \+/-687.43' +/ s.o3' \ w SQ. FT. 1721 \ - > 86 ` a v o2 - - - - 83 - - - - - _ _ SQ. FT. 2084 - W F — P \ \ - - a F. 'SQ. FT. /< 162 1618 \\ 1 L 1 L' o Q o v o -682- , _SQ FT. - 2014 I / v z 1 - - - / - Q. FT. i x > n O \ 683_ SQ, FT.� 2135 2135 c ~ U) 1-640 + I', 1 \ - - SQ. FT. SQ. FT. 4 ° ry __'_- - i / / L \ \y� - _ _ -SQ. FT. SQ. T. - e9 a w 00 77 _ I o 680 i 679.6 - V 610 -----_ - I 1 I - I I 1 � SAN - --- _ SAN v ---- ` ' z i - i ESAN_- w w \ - 8 ENN L / SAN - I = a -7 BLEW/DTH _ I w Q O (f'R/VATEJ 8� - v - z 'LN I I �� seg \ DATE e I- ------- - - 680 - 9'1nr \ \ i i 0412612021 1 yam_.._..... - 68 1 - ------- I _ _ 2 _ _ _ �6 FENNEL ROAD O DRAWN BY 1J_- /" - - FT. _ - '(5) ACE OGL_ �� W/DTH — _- _ % _ i - - -I — — — r ^ M. RACHNER - T bo PRIV E)R/Wr \ II I I DB 5074,'PG 2341C / �� 1 _ _ _ - _ - • DESIGNED BY -r------- ,- ---- -- - 1, i - � I � M. R,QCHNER II '!1 i i I • CHECKED BY 3122 I • C. SHIFFLETT - I SQ. FT. 2445 ' I I • • SCALE • SQ. FT. 69, 1738 1735 1732 I I 1 " = 20' SQ. FT. -SQ. FT. SQ. FT. 2203 0 \ SQ. FT. 2145 " - \ ' I \ SQ. FT. 1732 �SQ. FT. 1732 1730 1 SQ. FT. SQ. FT. 2016 I I I I 1 ( SQ. FT. 3307 `0 I I - - 1- _686- SQ. FT. - r _ a - - 1 I I — i/_ 686 2 GREENWELL LANE (� �2 • sas SO 4FT \ bs p \ \ _• DB, 5024, PG. 429 v 0 r , X -(7) BET CIM I , N O a Z (D Z Lu > 0- v - JLLJ J LIJ 5333 tiV rI I z: Q SQ. FT. v — • i ---->� _j m �ti J Q U) (9) QUE PHE � � v � Z ' (7) QUE PAL ? J • // 3976 ` Y 663 L I� O SQ. FT. 61,/PUB Lq�� 6835 I"I'\ DB 4�04 PG 389 SQ. FT.0 i r I \ I I I 1 I Oly�am b r I r \ r I r \ I I JOB NO. 47652 SCALE V=20' SHEET NO. 0 20' 40' L 1.0 L PRUNE CODOMINATE LEADERS REMOVE BROKEN, BADLY DEFORMED, RUBBING, NARROW CROTCH ANGLES, WATER SPROUTS, OR CROSS -BRANCHES. REMOVE TAGS, LABELS, AND PLASTIC SLEEVING. DO NOT STAKE UNLESS SPECIFIED (SEE NOTE) DO NOT WRAP TRUNK PRUNE SUCKERS IF FIELD GROWN, CUT AWAY ALL BALLING ROPES. REMOVE BURLAP OR WIRE BASKET FROM TOP % OF BALL. IF CONTAINER GROWN, REMOVE CONTAINER AND CUT CIRCLING ROOTS 1:1 SLOPE OF SIDES OF PLANTING HOLE SCARIFY SIDES BEFORE PLANTING TAMP SOIL AROUND ROOTBALL BASE FIRMLY WITH FOOT PRESSURE SO THAT ROOTBALL DOES NOT SHIFT DECIDUOUS TREE - STAKING SPECIFIED NOT TO SCALE PLANT SCHEDULE TREES QTY BOTANICAL NAME COMMON NAME MIN. INSTALLED SIZE ROOT CANOPY ACE OGL 9 ACER RUBRUM 'OCTOBER GLORY' OCTOBER GLORY RED MAPLE 2.5" CAL. B&B 452SF BET CIM 8 BETULA NIGRA'CULLY IMPROVED' TM HERITAGE IMPROVED RIVER BIRCH 2.51, CAL. B&B 464SF QUE PAL 9 QUERCUS PALUSTRIS PIN OAK 2.5" CAL. B&B 419SF QUE PHE 9 QUERCUS PHELLOS WILLOW OAK 2.5" CAL. B&B 419SF STREET TREE REQUIREMENTS * per Sec. 32.7.9.5 of the Albemarle County Code STREET LENGTH REQUIREMENTS CALCULATIONS REQUIRED PROVIDED ORION LANE 279.7 LF 1 LG TREE PER 50 LF 280.0 / 50 = 5.6x2 = 11.2 12 LG TREES 12 LG TREES EXTENDED OLD TRAIL DRIVE 343.9 LF 1 LG TREE PER 50 LF 344.0 150 = 6.88 7 LG TREES 7 LG TREES TREE COVER CALCULATIONS * per Sec. 32.7.9.8 of the Albemarle County Code SITE AREA REQUIREMENT CALCULATION REQUIRED QUANTITY PROVIDED QUANTITY 2.73AC 2.73ACx.1 (GROSS SITE AREA) 10% COVER = 0.273 AC 11,892 SF 12,212 SF = 11,891.9 SF NOTE: -ALL SITE PLANTINGS OF TREES AND SHRUBS SHALL BE ALLOWED TO REACH, AND BE MAINTAINED AT, MATURE HEIGHT; THE TOPPING OF TREES IS PROHIBITED. SHRUBS AND TREES SHALL BE PRUNED MINIMALLY AND ONLY TO SUPPORT THE OVERALL HEALTH OF THE PLANT. =W ROOT BALL 12 GAUGE GALVANIZED WIRE 3-2"x2" HARDWOOD STAKES GALVANIZED WIRE GUY 12 GAUGE. ALLOW FOR A SLIGHT AMOUNT OF MOVEMENT 8' 2"x2" HARDWOOD STAKE, 2'-6" MIN BELOW SURFACE. STAKE SHALL BE DRIVEN A MIN 18" OUT FROM TRUNK AND OUTSIDE OF ROOTBALL 2-3" MULCH LAYER TO EDGE OF DRIPLINE. KEEP 4-6" AWAY FROM TRUNKFLARE SET ROOTBALL FLUSH TO GRADE OR 1-2" HIGHER IN SLOWLY DRAINING SOILS. DO NOT COVER THE TOP OF THE ROOTBALL WITH SOIL. ROOTFLARE SHALL BE VISIBLE ABOVE FINISHED GRADE 6"SAUCER BACKFILL PLANTING PIT WITH NATIVE SOIL. INCORPORATE SLOW -RELEASE GRANULAR FERTILIZER 1" COMPOST LAYER PLACE ROOTBALL ON UNEXCAVATED OR TAMPED SOIL NOTE: ONLY STAKE TREES WITH LARGE CROWNS, 2" CALIPER OR GREATER, IF LOCATED ON WINDY SITES, OR WHERE TAMPERING MAY OCCUR. GENERAL NOTES PRE -CONSTRUCTION • CONTRACTOR IS RESPONSIBLE FOR CONTACTING "MISS UTILITY" AT 1.800.552.7001 FOR LOCATION OF ALL UTILITY LINES.TREES SHALL BE LOCATED A MINIMUM OF 5 FEET FROM SEWERNVATER CONNECTIONS. NOTIFY LANDSCAPE ARCHITECT OF CONFLICTS. • VERIFY ALL PLANT MATERIAL QUANTITIES ON THE PLAN PRIOR TO BIDDING, PLANT LIST TOTALS ARE FOR CONVENIENCE ONLY AND SHALL BE VERIFIED PRIOR TO BIDDING. • PROVIDE PLANT MATERIALS OF QUANTITY, SIZE, GENUS, SPECIES, AND VARIETY INDICATED ON PLANS. ALL PLANT MATERIALS AND INSTALLATION SHALL COMPLY WITH RECOMMENDATIONS AND REQUIREMENTS OF ANSI Z60.1 "AMERICAN STANDARD FOR NURSERY STOCK". IF SPECIFIED PLANT MATERIAL IS NOT OBTAINABLE, SUBMIT PROOF OF NON AVAILABILITY TO THE LANDSCAPE ARCHITECT, TOGETHER WITH PROPOSAL FOR USE OF EQUIVALENT MATERIAL. • PROVIDE AND INSTALL ALL PLANTS AS IN ACCORDANCE WITH DETAILS AND CONTRACT SPECIFICATIONS. • SOIL TESTS SHALL BE PERFORMED TO DETERMINE SOIL CHARACTER AND QUALITY. NECESSARY SOIL AMENDMENTS SHALL BE PERFORMED PER TEST RESULTS TO ENSURE PLANT HEALTH. CONSTRUCTION/INSTALLATION • LANDSCAPE ARCHITECT RESERVES THE RIGHT TO REJECT ANY PLANTS AND MATERIALS THAT ARE IN AN UNHEALTHY OR UNSIGHTLY CONDITION, AS WELL AS PLANTS AND MATERIALS THAT DO NOT CONFORM TO ANSI Z60.1 "AMERICAN STANDARD FOR NURSERY STOCK" • LABEL AT LEAST ONE TREE AND ONE SHRUB OF EACH VARIETY AND CALIPER WITH A SECURELY ATTACHED, WATERPROOF TAG BEARING THE DESIGNATION OF BOTANICAL AND COMMON NAME. • INSTALL LANDSCAPE PLANTINGS AT ENTRANCES/EXITS AND PARKING AREAS ACCORDING TO PLANS SO THAT MATERIALS WILL NOT INTERFERE WITH SIGHT DISTANCES. • CONTRACTOR IS RESPONSIBLE FOR WATERING ALL PLANT MATERIAL DURING INSTALLATION AND UNTIL FINAL INSPECTION AND ACCEPTANCE BY OWNER. CONTRACTOR SHALL NOTIFY OWNER OF CONDITIONS WHICH AFFECTS THE GUARANTEE. INSPECTIONS/GUARANTEE • UPON COMPLETION OF LANDSCAPE INSTALLATION, THE LANDSCAPE CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR WHO WILL VERIFY COMPLETENESS, INCLUDING THE REPLACEMENT OF ALL DEAD PLANT MATERIAL. CONTRACTOR IS RESPONSIBLE FOR SCHEDULING A FINAL INSPECTION BY THE LANDSCAPE ARCHITECT. • ALL EXTERIOR PLANT MATERIALS SHALL BE GUARANTEED FOR ONE FULL YEAR AFTER DATE OF FINAL INSPECTION AGAINST DEFECTS INCLUDING DEATH AND UNSATISFACTORY GROWTH. DEFECTS RESULTING FROM NEGLECT BY THE OWNER, ABUSE OR DAMAGE BY OTHERS, OR UNUSUAL PHENOMENA OR INCIDENTS WHICH ARE BEYOND THE CONTRACTORS CONTROL ARE NOT THE RESPONSIBILITY OF THE CONTRACTOR. • PLANT MATERIAL QUANTITIES AND SIZES WILL BE INSPECTED FOR COMPLIANCE WITH APPROVED PLANS BY A SITE PLAN REVIEW AGENT OF THE PLANNING DEPARTMENT PRIOR TO THE RELEASE OF THE CERTIFICATE OF OCCUPANCY. • REMOVE ALL GUY WIRES AND STAKES 12 MONTHS AFTER INSTALLATION. CLINT W. !: S FFLET a� Lic. N s43ee ��4'. 04/26/21 • i 'h'a::: •�''';•• ^� E 0 0 u N � N 0 > E w v E H_ w w 3 ¢ a o 3 p W — w0 `mom d' W L M ¢<� Voo W J —N M co, � z W U1 MI. �0 )x � Q v = N N F ¢ . 0 Y � N W M a� 00 J O W E z O a_ U c.I In W 0 z O N w w Q DATE 0412612021 DRAWN BY M. RACHNER DESIGNED BY M. RACHNER CHECKED BY C. SHIFFLETT SCALE U U O co 1 (W V Q J J I\ —I r) J O N/A Q z (D w J Q w m J LL 0 z 0 U r) z Q W F— O z LU n a U U) 0 Q J L H JOB NO. 47652 SHEET NO. L2.0