Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUB200800124 Application 2008-04-23
l r Count of Alb iarle Commune velopment Department,Zoning& arm • Y Current Development Division 401 McIntire Road Charlottesville,VA 22902-4596 Planning Application 1 Voice (434)296-5832 Fax.(434)972-4126 PARCEL I OWNER INFORMATION TMP 07700-00-00-008B0 Owner(s): AVON COURT HOLDINGS LLC s r Application# .SDP200800069-- 306 d.e_ j 2-V PROPERTY INFORMATION Legal Description ACREAGE Magisterial Dist. Scottsville Land Use Primary Residential --Single-family(incl. modular homes) Current AFD Not in A/F District Current Zoning Primary Light Industry APPLICATION INFORMATION House # Street Name Apt/Suite City State Zip Street Address 2085 AVON CT CHARLOTTESVILLE 22902- Entered By: Carla Hams on 04/24/2008 Application Type Site Development Plans Project' Avon Court Road Plans-Final 5,848.00 Received Date 04/23/2008 Received Date Final Total Fees $410.00 Submittal Date 04/28/2008 Submittal Date Final Total Paid $410.00 Closing File Date Revision Number Comments: Legal Ad SUB APPLICATION(s) Type Sub Application Date Comments. Final - Non-residential-Commission 04/24/2008 APPLICANT/ CONTACT INFORMATION Primary Contact Name Collins Engineering/Scott Collins,PE Phone # (434)987-1631 Street Address 800 E.Jefferson Street Fax # (434) 245-0300 City/State Charlottesville,Va Zip code 22902-0000 E-mail scott©collins-engineering.com Cellular# ( ) - Owner/Applicant Name AVON COURT HOLDINGS LLC Phone # ( ) - Street Address 321 EAST MAIN ST SUITE 200 Fax # ( ) - City/State CHARLOTTESVILLE VA Zip code 22902- E-mail Cellular# ( ) - Signature of Contractor or Authorized Agent Date \/'..,/ I T H D 1 AWN Per Zoning Ordinance U4, (,JD1 U� lication for -�PP It Site Development Plans and Site Plan Waiver '`` SITE DEVELOPMENT PLANS SITE PLAN WAIVER ❑ Preliminary Site Development Plan(Subject to Planning Commission Review) ❑ Site Plan Waiver (Ordinance Section Number) =$270 ❑ Residential=$1,190 plus$13/dwelling unit 8 folded copies of sketch plan are required ❑ Non-residential=$1,580 plus$13/1,000 sq.ft.of dev. 17folded copies of plan are required ® Final Site Development Plan(Administrative Review) ❑ Residential=$410 ® Non-residential=$410 8 folded copies of plan are required for first submission OR ❑ Final Site Development Plan(Subject to Planning Commission Review) ❑ Prior to preliminary approval=$1,130 17 folded copies of plan are required ❑ After preliminary approval=$790 8 folded copies of plan are required for first submission Two(2)mylars and two(2)paper copies of plan are required for signing offinal plan For all Preliminary Site Plans,Final Site Plans prior to preliminary approval,and Site Plan Waivers ❑ Tier 3 Groundwater Review=$400 plus$25 per dwelling unit (Required for all plans showing a use that uses less than 2,000 gallons of water per day average) ❑ Tier 4 Groundwater Review=$1,000 (Required for all plans showing a use that uses Treater than 2.000 gallons of water per day ayeraaet Project Name: AVON COURT ROAD PLANS Tax map and parcel: 77-8B Magisterial District: Scottsville Zoning: 1-1 Physical Street Address(if assigned): N/A Location of property(landmarks,intersections,or other): Avon St. Extended,just south of City of Charlottesville Contact Person(Who should wecal/write concerning this project?): COLLINS ENGINEERING - attn: Scott Collins, PE Address 800 E. Jefferson St. City Charlottesville State VA Zip 22902 Daytime Phone(434) 987-1631 Fax#(434) 245-0300 E-mail scoff@eollins-engineering.com owner of Record AVON COURT HOLDINGS, LLC Address 321 EAST MAIN STREET, SUITE 200 C;� Charlottesville state VA Zip 22902 Daytime Phone( ) Fax#( ) E-mail Applicant(Who is the Contact person representing?): AVON COURT HOLDINGS, LLC Address City State Zip Daytime Phone( ) Fax#( ) E-mail FOR OFFICE USE ONLY i SDP# Fee Amount S ID Date Paid y1G✓ p gDy who?Col I ln S G I t 6• Receipt#�v '0 Ck# 753 1 By- County �" of Albemarle Department of Community Development 401 McIntire Road Charlottesville,VA 22902 Voice: (434)296-5832 Fax: (434)972-4126 5/1/06 Page 1 of2 Type of Development ❑ Residential ■0 Non-residential Type of unit(s): ❑ Commercial ® Industrial #of building(s): El Quasi-Public Sq.ft.of building(s): Sq.ft.of building(s): N/A-ROAD PLANS ONLY Acreage of site: 7.1 AC #of units per building: Acreage in open space: n/a Total#of units: Resulting density: Acreage in roads: 0.65 AC.R/W Acreage of site: Average gallons of water used per day: Acreage in open space: n/a Acreage in roads: Average gallons of water used per day: Intended use or justification for request: extension of Avon Court Owner/Applicant Must Read and Sign This site plan as submitted contains all of the information required by Section 32.5(Preliminary Plan)or Section 32.6(Final Plan)of the Albemarle County Zoning Ordinance. I understand that plans which lack information required by said sections shall be deemed incomplete and shall be denied by the agent within ten(10)days of submittal as provided in Section 32.4.2.1 or Section 32.4.3.3 as the case may be. For Final Plans Only:To the best of my knowledge,I have complied with Section 32.4.3.1 and obtained tentative approvals for all applicable c;;itions from the appropriate agencies. \ 4/23/08 Signature of• • , ontract Purchaser,Agent Date SCOTT COLLINS,PE 434-987-1631 Print Name Daytime phone number of Signatory 5/1/06 Page 2 of 2 Final __e Development Plan r Checklist Project Name: AVON COURT ROAD PLANS Firm: COLLINS ENGINEERING This checklist must be completed,signed and submitted with the application. The information contained in this checklist reflects the contents of the Site Plan Ordinance as of May 1, 2006. The applicant is responsible for insuring that no revisions to the Ordinance have occurred since preparation of this document. PF'A al Site Development Plan shall contain the following: reliminary approval letter with appropriate number of copies of the plan ❑ Written request for any waivers(attach to application): Please List: Q Site Plan Ordinance Section 32.6- Contents of final site plan In addition to containing all of the information required by the Contents of Preliminary Site Plan (section 32.5) a final site plan shall contain the following: 1. A final site plan together with amendments thereto shall be prepared and sealed, signed and dated by an architect, professional engineer, land surveyor,or certified landscape architect, each of whom shall be licensed to practice in the Commonwealth of Virginia. [32.6.1] 2. A final site plan shall be prepared on mylar, sepia or other such transparency material which shall be termed as the master drawing. Two(2)clearly legible blue or black line copies of the master drawing shall be submitted to the department of planning and community development. (Added 5-I-87) In addition, if review is required by the commission, one(1)reduced copy no larger than eleven(11)inches by seventeen (17) inches in size shall be submitted. [32.6.2] 3. Two(2)copies of a landscape plan shall be submitted with the final site plan if not previously submitted. //// [32.6.31 ;;1' 4. When the site plan is ready for final approval,the full-sized revised master drawing and a transparency copy of the master drawing shall be submitted for the agent's signature. Once the agent has signed the master drawing, he shall return the master drawing to the developer and the developer shall submit four(4)print copies of the signed master drawing to the agent. [32.6.4] A5. Unless otherwise approved by the agent,the final site plan shall be prepared to the scale of one(I) inch equals twenty (20)feet or larger or to such a scale as may be approved by the agent in a particular case; no sheet shall exceed thirty-six(36)inches by forty-two(42)inches in size. The site plan may be prepared on one(1)or more sheets. If prepared on more than one(1)sheet, match lines shall clearly indicate where the sheets join. The top of the sheet shall be approximately either north or east. [32.6.5] 6. The final site plan shall reflect conditions of approval of the preliminary site plan. The final site plan shall contain the following information in addition to all the information required on the preliminary site plan:[32.6.6] 7. Specific written schedules or notes as necessary to demonstrate that the requirements of this chapter are being satisfied. In addition to preliminary site plan information, indicate if sale or rental units; number of bedrooms per unit,and number of units per building if multi-family; specifications for recreational facilities. [32.6.6a] County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Voice: (434) 296-5832 Fax: (434) 972-4126 5/1/06 Page I of 3 ❑ 8. Proposed grading(up to twenty [20] percent slope,maximum two [2] foot contours; over twenty [20] percent slope, maximum five [5]foot con :). [32.6.6b] r9. Detailed plans for proposed water and sanitary sewer facilities, including: all pipe sizes,types and grades; proposed connections to existing or proposed central systems; location and dimensions of proposed easements and whether the same are to be publicly or privately maintained;profiles and cross sections of all water and sewer lines including clearance where lines cross;all water main locations and sizes;valves and fire hydrant locations; all sanitary sewer appurtenances by type and number;the station on the plan to conform to the station shown on the profile and indicate the top and invert elevation of each structure.[32.6.6c] _0. Detailed construction drainage and grading plans: 1. Profiles of all ditches and channels whether proposed or existing, showing: existing and proposed grades, and invert of ditches, cross pipes or utilities;typical channel cross sections for new construction;and actual cross sections for existing channels intended to remain; 2. Profiles of all storm sewer systems showing existing and proposed grades; 3. Plan view of all drainage systems with all structures, pipes,and channels numbered or lettered on the plan and profile views. Show sufficient dimensions and bench marks to allow field stake out of all proposed work from the boundary lines; 4. A drainage summary table for culverts, storm sewer and channels as described in the following example: Structure Number Description Length Invert in Invert out Slope Remarks (1) 42" RCPCIass III 50' 424.50 424.00 100.00% Provide 2, EW (2) DI-3B L=8 426.00 432.00 - IS-1 Top (3) PG-2A 400' 420.00 400.00 5.00% D=12" (4) Grade Swale 200' 420.00 415.00 2.50% D=18" 5. A legend showing all symbols and abbreviations used on the plan; 6. General notes,typical sections,and details of all items not covered by Virginia Department of Transportation standard drawings; 7. Flood plain limits for the one hundred year storm for all watercourses with an upstream drainage area of fifty(50) acres or more provided that the county engineer may waive this requirement for drainage areas of less than one hundred(100)acres upon determination that such information is unnecessary for review of the proposed development. [32.6.6d] 11. Typical street sections together with specific street sections where street cut or fill is five(5)feet or greater; centerline curve data; radius of curb returns or edge of pavement; location,type and size of proposed ingress to and egress from the site; together with culvert size; symmetrical transition of pavement at intersection with existing street;the edge of street surface or face of curb for full length of proposed street;when proposed streets intersect with or adjoin existing streets or travel-ways,both edges of existing pavement or traveiway together with curb and gutter indicated for a minimum of one hundred(100)feet or the length of connection,whichever is the greater distance. [32.6.6e] . 12. Signature panel for Department of Community Development. [32.6.6f] .Jd 13. For all parking and loading areas, indicate: size;angle of stalls;width of aisles and specific number of spaces required and provided,and method of computation. Indicate type of surfacing for all paved or gravel areas. [32.6.6g] ,"14. The final site development plan shall be dimensioned to at least the following standards for accuracy: 1. Boundary, setback and zoning lines-nearest one-one hundredth(0.01)of a foot; 2. Existing contours-one-half('Y2)of the contour interval required in section 32.6.6.b above; 3. Proposed contours-within one(1)foot horizontally and vertically; 4. Spot elevations-within one-tenth(0.10)of a foot; 5. Existing structures,utilities and other topographic features-within two(2)feet. For critical structures, accuracy should be within one-tenth(0.10)of a foot; 6. Proposed structures, roads, parking lots, and other improvements-within one hundredth(0.01)of a foot. [32.6.6h] 15. Landscape plan in conformance with section 32.7.9.[32.6.6iJ 5/1/06 Page 2 of 3 (,?� 16. Outdoor lighting information including a photometric plan and location, description, and photograph or diagram of each type of outdoor luminaire, 6.6j/ In addition to the items required by the ordinance,Albemarle County Engineer,Groundwater Program Authority,the Virginia Department of Transportation,the Albemarle County Service Authority,and the Thomas Jefferson Health District require these items on plats and plans submitted for preliminary approval. Plats and plans will not be rejected if these items are not present,but they are required for approval. These items are provided in an effort to communicate all preliminary comments. .,Girl.Reference the benchmarks used for surveys. (Albemarle County Engineering Policy) (mil. Indicate the available sight distance for entrances and left turn lanes. (Albemarle County Engineering Policy) 73. Label the maximum height of all retaining walls. (Albemarle County Engineering Policy) ,Er 4. Provide copies of off-site easements,or letters of intent to grant them from off-site property owners. (Albemarle County Engineering Policy) A5. Show and label stream buffer limits. (WRPA Ordinance) sV 6. Indicate the deed book and page reference for all existing utility easements located on the property. (Albemarle County Service Authority) �7.Tier 3 -Draft or Final Groundwater Management Plan(17-403) 0 8.Tier 4—Aquifer testing work plan(17-403) Read and Sign In representing the above referenced firm submitting this plan for final approval, I hereby sate that, to the best of my knowl dge, the attached plan contains all information required by this checklist. 4/23/08 Signature of O er,Contract Purchaser,Agent Date SCOT!'COLLINS, PE 434-987-1631 Print Name Daytime phone number of Signatory 5/1/06 Page 3 of 3