Loading...
HomeMy WebLinkAboutSDP202100007 Plan - Revision 2021-11-19 (2)S\ TMP 61-120W N/F WILLIAM EDWARD & JOHN A F SULLIVAN, DB io95 PG 237 ACREAGE: 0.49 AC ZONING: HC TMP: o61oo-00-00-12000 OWNER: MARTHA JEFFERSON HOSPITAL c/o SENTARA HEALTHCARE ACREAGE: 4.369 AC ZONING: HC DB/PG: 4045/6o83 \920F \ / NOTE: EXISTING MECHANICAL >\ \ EQUIPMENT FOR THE BUILDING HVAC \ SHALL REMAIN. IF ANY REPLACEMENT EX. FIRE EQUIPMENT IS PROPOSED OR REQUIRED, HYDRANT TO THE NEW EQUIPMENT SHALL NOT BE REMAIN VISIBLE FROM THE EC STREETS. \ , TMP: 06100-00-oo-12oNo OWNER: MERCHANTS 7 T \\ m \\\0 r� 7J O v Z uo 013 EX. WATER METER FOR BUILDING TO REMAIN 5' UTILITY EASEMENT DB 636 PG 500 i8o'TO NEAREST INTERSECTION (SEMINOLE TRAIL / ROUTE 29) EX. ENTRANCE/ ti EGRESS THE ASSOCIATES LIMITED LIABILIT t SITE /)l CO. c/o MARVIN F POER COMPANY / ACREAGE: 0.41 /'® NO LEFT TURN ZONING: / MH / SIGN TO BE INSTALLED NEAR DB/PG: z 1/640 / / / _ _ENTRANCE - / EX. OVERHEAD POWER LINE TO REMAIN PROPOSEDCG/z \ " ' VDOT UTILITY & / \ \'q CENTURYLINK / PROPOSEDVDOT \ \•_ EASEMENT - - - -' / STD. CG 6 \ B"4E4T PG T39 DISPLAY \ \, TMP: o6100-00-oo-123Ho OWNER: CIP HOLDINGS II LLC CVS HEALTH #10746-oi ACREAGE:1.536oAC ZONING: HC DB/PG: 5107/433 IN 4� L O� 00 o PARKING SPACES 20I o / R �'� \ \ \ v PORTION OF a PORTION OF EXISTING CONCRETE TYP.) ( BENCHMARK / / ^ / \ l� EXISTING WALL ° RETAINING WALL AND N-3917614.40 / / = PROPOSED z' TO BE REMOVED SAFETY RAILING TO E-11490168.00 / / CURB CUT \ BE REMOVED, SEE SHEET 4 PROPOSED VDOT m (TYP,) NAEL-511.78 STD. CG-6 r / VEPCO 9L�F+ / ��ASEMENT DB L o.Z- 335 PG 458 ® /* ®' EX. SD EX. POWER POLETO REMAIN / 9, SIDEWALK _A RIO ROAD EMAIN PROPOSED2' VARIABLE WIDTH R/W eG _I. ,00� EX. SIDEWALK TO O CURB CUT '/, DB 4685 PC 642 BE EXPANDED TO (TYP.) RETAINING / 5' MIN. # WALL w/RAILING 15 R- \ \ 1 STORY - \ \ IT CONC. BUMPER \ \ FRAME &STUCCO ® BLOCKS 680 # PROPOSED SSMH (TYP.) / % \ # EX. SIDEWALK * CG I TRAFFIC SIGNAL MH / J� \\ DISPLAY T. REMAIN BOX DISPLAY 3 \ PARKING SPACES PARKING SPACES (TYP.) \ \�" PROPOSED 9' • , PROPOSED VDOT CONC. SIDEWALK �s 1) STD CG-6_ TRAFFIC SIGNAL i POLE MIT / \ � VESTI ULE / ti r f� PROPOSED CG-z TRAFFIC SIGNAL, RET. WALL & SIDEWALK Az EASEMENT \ y PROPOSED CG-z 2 DB 4685 PG 642 DUMPSTER REMOVED PROPOSED z' AND (2) ADDITIONAL\\ \ \ / 3' / CURB CUT EMPLOYEE/CUSTOMER \ \\ PROPOSED 6 __ / (TYP.) PARKING SPACES - ..GONG. SIDEWALK - / / TRAFFIC SIGNAL DL=6" / ADDED CUSTOMER rA- POLE \ PARKING SPACES�r/ (TYP.) \ \ 1)09 -7 - / DMH PROPOSED CONC. 24 21 © PROPOSED VDOT 3'R- �� 0) A' / DRAINAGE FLUME COIF V � C. EX. CONC. STD. CG iz v CURBING TO io`R �P� - j DITCH REMAIN EXIS i / / V a� NO SCALE CONC. BUMPER HANDI SIGN J �s S/W LN o�' f / / / � y'� `�� �� `O J,6" THICK CONCRETE DITCH WITH BLOCKS A6"x6" W2.1XW2.1 WELDED (TYP.) �508-' -/ / REINFORCEMENT MESH EXIS . / - m� �� Q,� �� AND A BROOM FINISH HANDIC SIGN / TRAFFIC SIGNAL TMP: o6100-00-oo-l2000 or BOX EX. HANDICAP OWNER: SOMMERHOFF, LLC PARKING SPACES 7 3'R / / TRAFFIC SIGNAL ACREAGE: 0.87 AC TO REMAIN PROPOSED / ZONING: HC CG-z I / \ SIDEWALK EASEMENT DB/PG: EX. SAN SWR TO W / DB 4685 PG 642 4755/209 PROPOSEDVDOT / \ REMAIN � _ _STD. CG U `` 506 ® / \. EX. STREET EX. ADA HANDICAP EX. ENTRANCE/ ° LIGHT TO \ RAMP TO REMAIN EGRESS TO THE \ u , REMAIN \ / BENCHMARK \ N-3917459.59 A \ 5� E-11490319.77 \ \ EX. SIDEWALK ELEV-506.44 of TO REMAIN NAIL 30' ACCESS EASEMENT DISPLAY DB 636 PG 500 ' PARKING SPACES L EX. DROP (TYP.) / INLET TO REMAIN / \ EX. STREET / EX. CONC. \ \ LIGHT TO CURBING TO REMAIN REMAIN \ \ EX. TREE TO \ REMAIN \ \ EXISTING 1 STORY 60ILD(NG TO REMAIN 20 GRAPHIC SCALE 10 20 40 ( IN FEET ) 1 inch = 20 ft. 80 NOTE: 1. CONTRACTOR SHALL VERIFY ALL ROAD CONNECTIONS, INCLUDING RECENTLY CONSTRUCTED AREAS, VERTICALLY AND HORIZONTALLY PRIOR TO CONSTRUCTION AND SHALL NOTIFY ENGINEER OF ANY DISCREPANCIES. z. CONTRACTOR SHALL CONFIRM ALL UTILITY, DRAINAGE, AND ROAD CONNECTIONS, AND SHALL NOTIFY ENGINEER OF ANY TIE-IN ISSUES OR DISCREPANCIES. 3. Oi REPRESENTS ONE PROPOSED PARKING SPACE. 4. OVERHEAD WIRING OR OTHER OBSTRUCTIONS SHALL BE HIGHER THAN 13'-6". 5. ALL PAVEMENT SHALL BE CAPABLE OF SUPPORTING FIRE APPARATUS WEIGHING 85,000 LBS. 6. CONTRACTOR SHALL ENSURE ALL ON -SITE UTILITIES, ABOVE AND BELOW GROUND, SERVICING ADJACENT PROPERTIES SHALL CONTINUE TO SERVICE THE ADJACENT PROPERTIES THROUGHOUT CONSTRUCTION AND UPON COMPLETION OF THE PROJECT TO THE FULLEST EXTENT POSSIBLE. 7. CURB RADII SHOWN, REPRESENTED WITH AN'R', DIMENSION THE FACE OF CURB. 8. ANY RETAINING WALLS GREATER THAN 3 FEET IN HEIGHT REQUIRE A SEPARATE BUILDING PERMIT. WALLS EXCEEDING 4 FEET IN HEIGHT REQUIRE A STAMPED ENGINEERED DESIGN FOR THE WALLS SYSTEM. 9. BUILDINGS OR STRUCTURES BUILT BEFORE JANUARY 1, 1985 MUST HAVE AN ASBESTOS SURVEY PERFORMED IN ORDER TO APPLY FOR A DEMOLITION PERMIT. ASBESTOS REMOVAL PERMITS ARE REQUIRED IF POSITIVE FOR SUCH. CONTACT VDOLI FOR ADDITIONAL REQUIREMENTS AND PERMITS FOR DEMOLITION PROJECTS. io. ALL PRIVATE TRAVELWAYS SHALL BE OWNED AND MAINTAINED BY THE OWNER. NO PUBLIC AGENCY, INCLUDING VDOT AND THE COUNTY OF ALBEMARLE WILL BE RESPONSIBLE FOR MAINTAINING THE TRAVELWAYS ON THE PROPERTY. ii. ALL PUBLIC WATER AND SANITARY SEWER FACILITIES SHALL BE DEDICATED TO PUBLIC USE AND THE EASEMENTS FOR THOSE FACILITIES, AS IDENTIFIED ON THIS PLAN, SHALL BE DEDICATED TO THE ALBEMARLE COUNTY SERVICE AUTHORITY. SITE PLAN NOTES: 1. SEE SHEET 2 FOR BOUNDARY DIMENSIONS, METES AND BOUNDS, AND SURVEY INFORMATION. 2. TRASH SHALL BE STORED & COLLECTED IN THE DUMPSTER CONTAINER, SHOWN ON THIS SHEET. 3. CONTRACTOR SHALL RELOCATE UNDERGROUND AND OVERHEAD UTILITIES AS NECESSARY. CONTRACTOR TO WORK WITH UTILITY COMPANY FOR THE DESIRED LOCATIONS. 4. INDIVIDUAL SIGNS WILL REQUIRE SIGN APPLICATIONS AND SIGN DESIGNS WILL BE REQUIRED TO MEET STANDARD SIGN GUIDELINES REGARDING SIZE, SCALE AND PROPORTION RELATIVE TO THE SIGN BAND AND THE OVERALL BUILDING. S. ANY CONCRETE SIDEWALK ALONG RIO ROAD OR ROUTE 29 (SEMINOLE TRAIL) SHALL BE REPLACED WITH THE CONSTRUCTION OF THE ONSITE IMPROVEMENTS. 6. THE SITE DEVELOPMENT AND USAGE OF THE PROPERTY FOR DISPLAY PARKING SHALL COMPLY WITH THE CONDITIONS OF THE APPROVED SPECIAL USE PERMIT. THE CONDITIONS ARE LISTED ON SHEET OF THIS SITE PLAN AMENDMENT. ENTRANCE CORRIDOR NOTES AND REQUIREMENTS: 1. VEHICLES SHALL NOT BE ELEVATED ANYWHERE ON SITE. 2. VEHICLES SHALL BE STORED AND DISPLAYED ONLY IN AREAS INDICATED FOR STORAGE OR DISPLAY SHOWN ON THIS APPLICATION PLAN. DISPLAY PARKING SHALL NOT BE LOCATED ON EXISTING GRASS OR LANDSCAPE AREAS. 3. SALES DISPLAY AND CUSTOMER PARKING SPACES AS SHOWN ON THE APPLICATION PLAN SHALL BE STRIPED/MARKED ON SITE. 4. THE PROPOSED LANDSCAPING AS SHOWN ON SHEET 5 IS PROPOSED TO COMPENSATE FOR THE NEGATIVE VISUAL IMPACT OF THE PROPOSED USE FROM THE ENTRANCE CORRIDOR. 5. ANY ACCESSORY STRUCTURES OR EQUIPMENT MUST BE SCREENED FROM VIEW FROM THE ENTRANCE CORRIDOR, AND ANY ACCESSORY STRUCTURE OR EQUIPMENT IS SUBJECT TO ARB REVIEW. 6. ANY ALTERATIONS TO THE EXISTING BUILDING THAT ARE VISIBLE FROM THE ENTRANCE CORRIDOR, INCLUDING THE ADDITION OF WALL -MOUNTED LIGHTING, ARE SUBJECT TO ARB REVIEW. 7. SEE SITE PLAN FOR DEMARCATION OF THE LOADING AND SERVICE AREAS, REFUSE AREAS, EXISTING AND PROPOSED MECHANICAL EQUIPMENT, AND OTHER SITE RELATED FEATURES. ALL TRASH RECEPTACLES SHALL BE STORED BEHIND THE BUILDING OR ON THE SOUTHWEST SIDE OF THE BUILDING. 8. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. 9. ANY MODIFICATION TO THE EXISTING SITE LIGHTING IS SUBJECT TO ARB REVIEW AND APPROVAL. MAXIMUM LIGHT LEVELS ON THE SITE SHALL NOT EXCEED 30 FOOT CANDLES. 10. ALL SIGNS FOR THE SITE SHALL BE REVIEWED AND APPROVED BY ARB UNDER A SEPARATE SIGN APPLICATION. 11. A KNOX BOX IS REQUIRED FOR THE BUILDING. THE LOCATION OF THE KNOX BOX SHALL BE COORDINATED WITH THE FIRE MARSHALL'S OFFICE. 12. THE ISO FIRE FLOW FOR THE EXISTING BUILDING IS 1000 GPM. NO SPRINKLER SYSTEM IS NECESSARY. 13. THE AVAILABLE FIRE FLOW FOR THE SITE IS 1860 GPM AT 65 PSI. / LEGEND EXISTING BUILDINGS PROPOSED DISPLAY PARKING EMPLOYEE/CUSTOMER PARKING TRAVELWAYS LANDSCAPING AREAS PROPOSED PARCEL BOUNDARY TMP: o61oo-00-00-123Ao OWNER: CHARLOTTESVILLE S&L ASSOC c/o SUNTRUST BANK CORP REAL ESTATE ACREAGE:1.igAC ZONING: PD-SC DB/PG: 514/374 SCOTT/R. Cb'LLINS'Z Lie. No. 035791 n 11/18/21�� k I co I I =) 7 I O F OC a Ll V) u U in z Lu i w � z I o z O O I H > z U)Lu 3 i in Lu J : III LL i I w D z z o U) o > z ' g o ) a � Lu w i k J J z i ai Lu rn v m QQ .+ CD r4 .+ 0 0 0 .� L ti M CA N co It O W C>7 N N W > Lu J U) Lu uO U W ' Lu ul U) Lu Lu z ® U) JLLJ ~ JQ O 0 W 0 Lu U 0 a za C ° o uj y Cn ° L N O° z o CAI a G 0 Q m r-I J s Lu U LL.LL w 1_4 o J a E Q Lu 0 ° 0 C ° Z Q � w w z J Q N I Z 0 U Lu ° J O a 0 z U X Lij (n L O Lu ° F- U F w E W U d E JOB NO. ° 0 202185 0 SCALE ° 1 "=20' C SHEET NO. a 3 L H 0 0 0 L