HomeMy WebLinkAboutVA200400014 Review Comments 2004-08-18 VA 0 Lf' - A Ivy Page 1 of 1
Jan Sprinkle
From: Jay Schlothauer
Sent: Wednesday, August 18, 2004 11:34 AM
To: Jan Sprinkle
Subject: RE: code?
I will assume that this is a residential accessory structure If the shed is less than 3'from a property line, the shed
wall facing that property line is required to be constructed as a 1-hour firerated wall. Because of the small size of
the shed (<150 sq. ft.), a permit is not required for its construction. However, exception from the requirement for a
permit does not exempt the structure from the building code.
From: Jan Sprinkle
Sent: Wednesday, August 18, 2004 11:24 AM
To: Jay Schlothauer
Subject: code?
We have a situation where a storage shed was installed 3"from a property line. Does that matter to the building
code? Does the size make any difference? I think it's only 8x12.
8/18/2004