HomeMy WebLinkAboutFDP202100003 Correspondence 2021-11-23 (2)Dustin Greene
From:
Frank Pohl <fpohl@albemarle.org>
Sent:
Wednesday, June 2, 2021 5:23 PM
To:
Dustin Greene
Cc:
Nystrom, Jonathan; cgathright@dgarchs.com
Subject:
RE: Planning Application Review for FDP202100003 NYSTROM DRIVEWAY CROSSING.
Dustin,
"agate, my mistake, this does not need SWM, but will need a VESCP plan. I've changed my comment to refer to a VESCP
only. 0.414 Lop t It sf A4%- 1 4 ere
Sorry for the confusion... `'f
Frank l�iS C. P gk L 0% ILr wti'
•
Frank V. Pohl, PE, CFM
County Engineer
Albemarle County
fpohl@albemarle.org
434-296-5832 x7914
401 McIntire Road, North Wing, Charlottesville, VA 22902
From: Dustin Greene <DGreene@roudabush.com>
Sent: Wednesday, June 2, 20214:21 PM
To: Frank Pohl <fpohl@albemarle.org>
Cc: Nystrom, Jonathan <JgNystrom@nycominc.com>; cgathright@dgarchs.com
Subject: RE: Planning Application Review for FDP202100003 NYSTROM DRIVEWAY CROSSING.
CAUTION: This message originated outside the County of Albemarle email system. DO NOT CLICK on links or open
attachments unless you are sure the content is safe.
Frank,
Thank you for your review. I know that everyone is incredibly busy right now. We had a back and forth with
you all last fall and I was under the impression that we could have an agreement in lieu of a plan for VSMP at
disturbance of less than an acre. Please see the attached email exchange from last year. Fell free to give me a call if you
think it is quicker than an email.
Best Regards,
Dustin Greene, PE
Roudabush, Gale & Associates, Inc
(o) 434-977-0205 ex - 724
(Direct)434-328-1069
(m)415-420-8238
dereeneC@roudabush.com
Physical Address:
999 Second Street SE
Suite 201
Charlottesville, VA 22902
rIx I MUNIM 11.
;/.N6 OLM9tA�Q
�NlFNCtAfMp
iANO RRI: e,..1'O
Mailing Address:
435 Merchant Square
Suite 300-159
Charlottesville, VA 22902
From: Frank Pohl <fpohl@albemarle.ore>
Sent: Tuesday, June 1, 2021 12:06 PM
To: Dustin Greene <DGreene@roudabush.com>
Subject: Planning Application Review for FDP202100003 NYSTROM DRIVEWAY CROSSING.
The Review for the following application has been completed:
Application Number = FDP202100003
Reviewer= Frank Pohl
Review Status = Requested Changes
Completed Date = 06/01/2021
This email was sent from County View Production.
Engineering Comments:
- Clearly show area of cut/fill on the plan/profile views with a hatch.
- Show stationing of driveway on plan views.
- Land disturbance does not qualify for an agreement in lieu of a plan. A VSMP application with mitigation for stream
buffer impacts is required.
- Confirm that plan view on Sheet 3 shows both abutments.
- Provide permitting approval letter from the ACOE prior to VSMP approval.
- Driveways cannot exceed 16% slope. Revise slope shown on Sheet 2 to be below 16%. Advise to adjust maximum slope
to 15%to allow for construction error.
Provide deck elevation on profiles on Sheets 2 and 3.
Confirm how proposed bridges will be anchored on bridge detail sheet. Provide a foundation design.
Show radii at entrance in accord with VDOT driveway entrance standards.
- Recommend confirming that VDOT will approve entrance location.
- Show parcel boundary on Sheet 4.
- Clearly identify proposed bridge locations on Sheet 4.
- Provide floodplain modeling data (inputs and outputs).
- Provide overall drainage area map.