HomeMy WebLinkAboutSE202000027 Plan - Approved 2021-11-29DocuSign Envelope ID: E8E41141-C22B-42DF-A957-564715F8CC8F AT&T SITE NUMBER: AT&T SITE NAME: AT&T FA CODE: AT&T PACE NUMBER: CV385 TOMLIN 10068605 MRVWN003799 AT&T PROJECT: LTE 3C SITE INFORMATION CROWN CASTLE USA INC. SITE NAME: SITE ADDRESS: COUNTY: MAP/PARCEL #: AREA OF CONSTRUCTION: LATITUDE: LONGITUDE: LAT/LONG TYPE: GROUND ELEVATION: CURRENT ZONING: JURISDICTION: OCCUPANCY CLASSIFICATION: TYPE OF CONSTRUCTION: A.D.A. COMPLIANCE: PROPERTY OWNER: TOWER OWNER: CARRIER/APPLICANT: ELECTRIC PROVIDER: TELCO PROVIDER: TOMLIN 1052 GOODWIN FARM LANE CHARLOTTESVILLE, VA 22903 ALBEMARLE 07500-00-00-00900 EXISTING 380 00' 31.40" -780 34' 19.70" NAD83 674 FT. RURAL AREAS ALBEMARLE COUNTY U IIB FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION TOMLIN, CHARLOTTE D 1651 ARROWHEAD VALLEY RD CHARLOTTESVILLE, VA 22903 CCATT LLC 2000 CORPORATE DRIVE CANONSBURG, PA 15317 AT&T TOWER ASSET GROUP 575 MOROSGO DRIVE ATLANTA, GA 30324-3300 DOMINION POWER (866) 366-4357 CENTURY LINK (800) 244-1111 DRAWING INDEX SHEET # SHEET DESCRIPTION T-1 TITLE SHEET T-2 GENERAL NOTES C-1.1 SITE PLAN C-1.2 EXISTING & FINAL EQUIPMENT PLANS C-2 FINAL ELEVATION & ANTENNA PLANS C-3 FINAL EQUIPMENT SCHEDULE C-4 EQUIPMENT SPECS E-1 POWER ANALYSIS G-1 GROUNDING SCHEMATIC G-2 GROUNDING DETAILS ATTACHED PLUMBING DIAGRAM ATTACHED UP CONVERTER TAG SHEETS ATTACHED MOUNT SPECIFICATIONS ALL DRAWINGS CONTAINED HEREIN ARE FORMATTED FOR FULL SIZE. CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. ® CALL VIRGINIA ONE CALL (800) 552-7001 0 CALL 3 WORKING DAYS BEFORE YOU DIG! BUSINESS UNIT #: SITE ADDRESS: COUNTY: SITE TYPE: TOWER HEIGHT: LOCATION MAP 9 38.00872, -78.572136 NO SCALE O�orso 916 842588 1052 GOODWIN FARM LANE CHARLOTTESVILLE, VA 22903 ALBEMARLE MONOPOLE 1051-01, PROJECT DESCRIPTION APPLICABLE CODES/REFERENCE DOCUMENTS THE PURPOSE OF THIS PROJECT IS TO ENHANCE BROADBAND CONNECTIVITY AND CAPACITY TO ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE EXISTING ELIGIBLE WIRELESS FACILITY. THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES: TOWER SCOPE OF WORK: CODE TYPE CODE • REMOVE (3) CCI ANTENNAS - TPA-65R-LCUUUU-H6-K ANTENNAS BUILDING 2015 VA CONSTRUCTION CODE/2015 IBC W/ VA AMENDMENTS • REMOVE (3) PIPE MOUNTS MECHANICAL 2015 VA CONSTRUCTION CODE/2015 IMC W/ VA AMENDMENTS • RELOCATE (6) COMMSCOPE - E15Z01P39 TMAs ELECTRICAL 2015 VA CONSTRUCTION CODE/2014 NEC W/ VA AMENDMENTS • INSTALL (3) KENWOOD - Z2058KT8-9114-M CUSTOM T-ARM MOUNTS • INSTALL (6) COMMSCOPE - NNH4-65B-R6N17 ANTENNAS • INSTALL (3) ERICSSON - 4478 B14 RRUs REFERENCE DOCUMENTS: • INSTALL (1) RAYCAP - DC9-48-60-24-EC-EV SQUID STRUCTURAL ANALYSIS: CROWN CASTLE • INSTALL (1) #8AWG DC CABLE (3/4") DATED: JUNE 17, 2020 • INSTALL (1) 24 PAIR FIBER CABLE (3/8") MOUNT REPLACEMENT ANALYSIS: ENGINEERED TOWER SOLUTIONS, PLLC DATED: JUNE 11, 2020 GROUND SCOPE OF WORK: • POWER ANALYSIS FAILED AC ELECTRICAL POWER DESIGN: BY OTHERS • INSTALL (3) EMERSON -48V RECTIFIERS IN EXISTING 512 POWER PLANT DATED: • INSTALL (3) 40 AMP DC BREAKERS FOR PROPOSED 4449 RRU's RFDS REVISION: 0.1 • INSTALL (3) 30 AMP DC BREAKERS FOR PROPOSED 4426 RRU's DATED: 05/12/2020 • INSTALL (3) VERTIV UP CONVERTERS FOR PROPOSED 4478 RRU's ORDER ID: 517627 • INSTALL (4) 170 AMP BATTERIES IN EXISTING BATTERY CABINET REVISION: 1 • INSTALL (1) 6630 IN EXISTING FLEX 16 • REMOVE (3) RRUS11 B12 FROM OUTDOOR H FRAME • INSTALL (3) 4449 B5/B12 ON OUTDOOR H FRAME INSTALLER NOTE: • INSTALL (3) 4426 ON OUTDOOR H FRAME INSTALLER NOTE: NO PROPOSED LOADING TO BE ADDED NOTE: UNTIL MOUNT SWAP IS COMPLETE. THE POWER DESIGN FOR ANY AC ELECTRICAL POWER CHANGES IS TO BE PERFORMED BY OTHERS EQUIPMENT To BE PAINTED WITH RF CONTRACTOR TO INSTALL MOUNT PER AND IS SHOWN HERE FOR REFERENCE PURPOSES ONLY. AT&T IS SOLELY RESPONSIBLE FOR THE TRANSNEW Z RAFTED MATCH STEXIISTI OUTDOOR MANUFACTURER'S SPECIFICATIONS. ELECTRICAL POWER DESIGN. J iiz AT &T 575 MOROSGO DRIVE ATLANTA, GA 30324-3300 CCCROWN C.A:5`T L E 3530 TORINGDON WAY, SUITE 300 CHARLOTTE, NC 28277 AT&T SITE NUMBER: CV385 BU #: 842588 TOMLIN 1052 GOODWIN FARM LANE CHARLOTTESVILLE, VA 22903 EXISTING 105'-0" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q 0 07/01/20 NH CONSTRUCTION MAM 1 07/07/20 AK CONSTRUCTION MAM 2 09/08/20 AK CONSTRUCTION MAM 3 12/02/20 CV CONSTRUCTION MAM by: II� aAt-Au'ssiL ;ED ABDEL-MESSIH Lic. No. 49004 1 5:57: Crown Castle USA Inc. COA #407005050 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: T-1 3 DocuSign Envelope ID: E8E41141-C22B-42DF-A957-564715F8CC8F CROWN CASTLE USA INC. SITE ACTIVITY REQUIREMENTS: GENERAL NOTES: ELECTRICAL INSTALLATION NOTES: 1. NOTICE TO PROCEED- NO WORK SHALL COMMENCE PRIOR TO CROWN CASTLE USA INC. WRITTEN NOTICE TO PROCEED (NTP) AND THE ISSUANCE OF A PURCHASE ORDER. PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE CROWN CASTLE USA INC. NOC AT 800-788-7011 & THE CROWN CASTLE USA INC. CONSTRUCTION MANAGER. 2. "LOOK UP" - CROWN CASTLE USA INC. SAFETY CLIMB REQUIREMENT: THE INTEGRITY OF THE SAFETY CLIMB AND ALL COMPONENTS OF THE CLIMBING FACILITY SHALL BE CONSIDERED DURING ALL STAGES OF DESIGN, INSTALLATION, AND INSPECTION. TOWER MODIFICATION, MOUNT REINFORCEMENTS, AND/OR EQUIPMENT INSTALLATIONS SHALL NOT COMPROMISE THE INTEGRITY OR FUNCTIONAL USE OF THE SAFETY CLIMB OR ANY COMPONENTS OF THE CLIMBING FACILITY ON THE STRUCTURE. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO: PINCHING OF THE WIRE ROPE, BENDING OF THE WIRE ROPE FROM ITS SUPPORTS, DIRECT CONTACT OR CLOSE PROXIMITY TO THE WIRE ROPE WHICH MAY CAUSE FRICTIONAL WEAR, IMPACT TO THE ANCHORAGE POINTS IN ANY WAY, OR TO IMPEDE/BLOCK ITS INTENDED USE. ANY COMPROMISED SAFETY CLIMB, INCLUDING EXISTING CONDITIONS MUST BE TAGGED OUT AND REPORTED TO YOUR CROWN CASTLE USA INC. POC OR CALL THE NOC TO GENERATE A SAFETY CLIMB MAINTENANCE AND CONTRACTOR NOTICE TICKET. 3. PRIOR TO THE START OF CONSTRUCTION, ALL REQUIRED JURISDICTIONAL PERMITS SHALL BE OBTAINED. THIS INCLUDES, BUT IS NOT LIMITED TO, BUILDING, ELECTRICAL, MECHANICAL, FIRE, FLOOD ZONE, ENVIRONMENTAL, AND ZONING. AFTER ONSITE ACTIVITIES AND CONSTRUCTION ARE COMPLETED, ALL REQUIRED PERMITS SHALL BE SATISFIED AND CLOSED OUT ACCORDING TO LOCAL JURISDICTIONAL REQUIREMENTS. 4. ALL CONSTRUCTION MEANS AND METHODS; INCLUDING BUT NOT LIMITED TO, ERECTION PLANS, RIGGING PLANS, CLIMBING PLANS, AND RESCUE PLANS SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR RESPONSIBLE FOR THE EXECUTION OF THE WORK CONTAINED HEREIN, AND SHALL MEET ANSI/ASSE A10.48 (LATEST EDITION); FEDERAL, STATE, AND LOCAL REGULATIONS; AND ANY APPLICABLE INDUSTRY CONSENSUS STANDARDS RELATED TO THE CONSTRUCTION ACTIVITIES BEING PERFORMED. ALL RIGGING PLANS SHALL ADHERE TO ANSI/ASSE A10.48 (LATEST EDITION) AND CROWN CASTLE USA INC. STANDARD CED-STD-10253, INCLUDING THE REQUIRED INVOLVEMENT OF A QUALIFIED ENGINEER FOR CLASS IV CONSTRUCTION, TO CERTIFY THE SUPPORTING STRUCTURE(S) IN ACCORDANCE WITH ANSI/TIA-322 (LATEST EDITION). 5. ALL SITE WORK TO COMPLY WITH QAS-STD-10068 "INSTALLATION STANDARDS FOR CONSTRUCTION ACTIVITIES ON CROWN CASTLE USA INC. TOWER SITE" AND LATEST VERSION OF ANSI/TIA-1019-A-2012 "STANDARD FOR INSTALLATION, ALTERATION, AND MAINTENANCE OF ANTENNA SUPPORTING STRUCTURES AND ANTENNAS." 6. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY CROWN CASTLE USA INC. PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OF INSTALLATION. 7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 8. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 9. THE CONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION. 10. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT ALL TIMES AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY CONTRACTOR. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES. CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS WILL INCLUDE BUT NOT BE LIMITED TO A) FALL PROTECTION B) CONFINED SPACE C) ELECTRICAL SAFETY D) TRENCHING AND EXCAVATION E) CONSTRUCTION SAFETY PROCEDURES. 11. ALL SITE WORK SHALL BE AS INDICATED ON THE STAMPED CONSTRUCTION DRAWINGS AND PROJECT SPECIFICATIONS, LATEST APPROVED REVISION. 12. CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATING WASTE MATERIAL, DEBRIS, AND TRASH AT THE COMPLETION OF THE WORK. IF NECESSARY, RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. 13. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF CONTRACTOR, TOWER OWNER, CROWN CASTLE USA INC., AND/OR LOCAL UTILITIES. 14. THE CONTRACTOR SHALL PROVIDE SITE SIGNAGE IN ACCORDANCE WITH THE TECHNICAL SPECIFICATION FOR SITE SIGNAGE REQUIRED BY LOCAL JURISDICTION AND SIGNAGE REQUIRED ON INDIVIDUAL PIECES OF EQUIPMENT, ROOMS, AND SHELTERS. 15. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE CARRIER'S EQUIPMENT AND TOWER AREAS. 16. THE SUB GRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO FINISHED SURFACE APPLICATION. 17. THE AREAS OF THE OWNERS PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT OR DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND STABILIZED TO PREVENT EROSION AS SPECIFIED ON THE CONSTRUCTION DRAWINGS AND/OR PROJECT SPECIFICATIONS. 18. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMENT CONTROL. 19. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. 20. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 21. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY BASIS. 22. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS, SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. GREENFIELD GROUNDING NOTES: 1. FOR THE PURPOSE OF CONSTRUCTION DRAWING THE FOLLOWING DEFINITIONS SHALL APPLY: CONTRACTOR: GENERAL CONTRACTOR RESPONSIBLE FOR CONSTRUCTION CARRIER: AT&T TOWER OWNER: CROWN CASTLE USA INC. 2. THESE DRAWINGS HAVE BEEN PREPARED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE ENGINEERS IN THIS OR SIMILAR LOCALITIES. IT IS ASSUMED THAT THE WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKPEOPLE WHO HAVE A WORKING KNOWLEDGE OF THE APPLICABLE CODE STANDARDS AND REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITION OR ELEMENT IS (OR CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR MISCELLANEOUS WORK NOT EXPLICITLY SHOWN. 3. THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE MEANS OR METHODS OF CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY FOR PROTECTION OF LIFE AND PROPERTY DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, FORMWORK, SHORING, ETC. SITE VISITS BY THE ENGINEER OR HIS REPRESENTATIVE WILL NOT INCLUDE INSPECTION OF THESE ITEMS AND IS FOR STRUCTURAL OBSERVATION OF THE FINISHED STRUCTURE ONLY. 4. NOTES AND DETAILS IN THE CONSTRUCTION DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT, AND/OR AS PROVIDED FOR IN THE CONTRACT DOCUMENTS. WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL NOTES, AND SPECIFICATIONS, THE GREATER, MORE STRICT REQUIREMENTS, SHALL GOVERN. IF FURTHER CLARIFICATION IS REQUIRED CONTACT THE ENGINEER OF RECORD. 5. SUBSTANTIAL EFFORT HAS BEEN MADE TO PROVIDE ACCURATE DIMENSIONS AND MEASUREMENTS ON THE DRAWINGS TO ASSIST IN THE FABRICATION AND/OR PLACEMENT OF CONSTRUCTION ELEMENTS BUT IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY THE DIMENSIONS, MEASUREMENTS, AND/OR CLEARANCES SHOWN IN THE CONSTRUCTION DRAWINGS PRIOR TO FABRICATION OR CUTTING OF ANY NEW OR EXISTING CONSTRUCTION ELEMENTS. IF IT IS DETERMINED THAT THERE ARE DISCREPANCIES AND/OR CONFLICTS WITH THE CONSTRUCTION DRAWINGS THE ENGINEER OF RECORD IS TO BE NOTIFIED AS SOON AS POSSIBLE. 6. PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING CONTRACTOR SHALL VISIT THE CELL SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND SHALL BE BROUGHT TO THE ATTENTION OF CROWN CASTLE. 7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 8. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 9. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 10. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE CARRIER AND CROWN CASTLE PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OF INSTALLATION. 11. CONTRACTOR IS TO PERFORM A SITE INVESTIGATION AND IS TO DETERMINE THE BEST ROUTING OF ALL CONDUITS FOR POWER, AND TELCO AND FOR GROUNDING CABLES AS SHOWN IN THE POWER, TELCO, AND GROUNDING PLAN DRAWINGS. 12. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF CROWN CASTLE USA INC. 13. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 14. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY BASIS. CONCRETE, FOUNDATIONS, AND REINFORCING STEEL: 1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 301, ACI 318, ACI 336, ASTM A184, ASTM A185 AND THE DESIGN AND CONSTRUCTION SPECIFICATION FOR CAST -IN -PLACE CONCRETE. 2. UNLESS NOTED OTHERWISE, SOIL BEARING PRESSURE USED FOR DESIGN OF SLABS AND FOUNDATIONS IS ASSUMED TO BE 1000 psf. 3. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH (f'c) OF 3000 psi AT 28 DAYS, UNLESS NOTED OTHERWISE. NO MORE THAN 90 MINUTES SHALL ELAPSE FROM BATCH TIME TO TIME OF PLACEMENT UNLESS APPROVED BY THE ENGINEER OF RECORD. TEMPERATURE OF CONCRETE SHALL NOT EXCEED 90°f AT TIME OF PLACEMENT. 4. CONCRETE EXPOSED TO FREEZE -THAW CYCLES SHALL CONTAIN AIR ENTRAINING ADMIXTURES. AMOUNT OF AIR ENTRAINMENT TO BE BASED ON SIZE OF AGGREGATE AND F3 CLASS EXPOSURE (VERY SEVERE). CEMENT USED TO BE TYPE II PORTLAND CEMENT WITH A MAXIMUM WATER -TO -CEMENT RATIO (W/C) OF 0.45. 5. ALL STEEL REINFORCING SHALL CONFORM TO ASTM A615. ALL WELDED WIRE FABRIC (WWF) SHALL CONFORM TO ASTM A185. ALL SPLICES SHALL BE CLASS "B" TENSION SPLICES, UNLESS NOTED OTHERWISE. ALL HOOKS SHALL BE STANDARD 90 DEGREE HOOKS, UNLESS NOTED OTHERWISE. YIELD STRENGTH (Fy) OF STANDARD DEFORMED BARS ARE AS FOLLOWS: #4 BARS AND SMALLER 40 ksi #5 BARS AND LARGER 60 ksi 6. THE FOLLOWING MINIMUM CONCRETE COVER SHALL. BE. PROVIDED FOR. REINFORCING. STEEL UNLESS SHOWN OTHERWISE ON DRAWINGS: CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" CONCRETE EXPOSED TO EARTH OR WEATHER: #6 BARS AND LARGER 2" . . #5 BARS AND SMALLER 1-1/2" CONCRETE NOT EXPOSED TO. EARTH. OR WEATHER: . SLAB AND WALLS . . . . 3/4". BEAMS AND COLUMNS 1-1/2" 7. A TOOLED EDGE OR A 3/4" CHAMFER SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE, UNLESS NOTED OTHERWISE, IN ACCORDANCE. WITH ACI 301. SECTION .4.2..4.. . . . . . . . . . . . 1. ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION AND AC POWER GES'S) SHALL BE BONDED TOGETHER AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN ACCORDANCE WITH THE NEC. 2. THE CONTRACTOR SHALL PERFORM IEEE FALL-OF-POTENTAL RESISTANCE TO EARTH TESTING (PER IEEE 1100 AND 81) FOR GROUND ELECTRODE SYSTEMS, THE CONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS OR LESS. 3. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT AND PROVIDE TESTING RESULTS. 4. METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTINGS OR BY BONDING ACROSS THE DISCONTINUITY WITH #6 COPPER WIRE UL APPROVED GROUNDING TYPE CONDUIT CLAMPS. 5. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT. 6. EACH CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL EQUIPMENT GROUND WIRES, #6 STRANDED COPPER OR LARGER FOR INDOOR BTS; #2 BARE SOLID TINNED COPPER FOR OUTDOOR BTS. 7. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED BACK TO BACK CONNECTIONS ON OPPOSITE SIDE OF THE GROUND BUS ARE PERMITTED. 8. ALL EXTERIOR GROUND CONDUCTORS BETWEEN EQUIPMENT/GROUND BARS AND THE GROUND RING SHALL BE #2 SOLID TINNED COPPER UNLESS OTHERWISE INDICATED. 9. ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING CONNECTIONS. 10. USE OF 90' BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45° BENDS CAN BE ADEQUATELY SUPPORTED. fr 11. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. 12. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR AND EXTERIOR) SHALL BE FORMED USING HIGH PRESS CRIMPS. 13. COMPRESSION GROUND CONNECTIONS MAY BE REPLACED BY EXOTHERMIC WELD CONNECTIONS. 14. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED TO THE BRIDGE AND THE TOWER GROUND BAR. 15. APPROVED ANTIOXIDANT COATINGS (i.e. CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. 16. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. 17. MISCELLANEOUS ELECTRICAL AND NON -ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND RING, IN ACCORDANCE WITH THE NEC. 18. BOND ALL METALLIC OBJECTS WITHIN 6 ft OF MAIN GROUND RING WITH (1) #2 BARE SOLID TINNED COPPER GROUND CONDUCTOR. 19. GROUND CONDUCTORS USED FOR THE FACILITY GROUNDING AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE ROUTED THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS METALLIC CONDUITS, METAL SUPPORT CLIPS OR SLEEVES THROUGH WALLS OR FLOORS. WHEN IT IS REQUIRED TO BE HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL CONDITIONS, NON-METALLIC MATERIAL SUCH AS PVC CONDUIT SHALL BE USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (i.e., NONMETALLIC CONDUIT PROHIBITED BY LOCAL CODE) THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT. 20. ALL GROUNDS THAT TRANSITION FROM BELOW GRADE TO ABOVE GRADE MUST BE #2 BARE SOLID TINNED COPPER IN 3/4" NON-METALLIC, FLEXIBLE CONDUIT FROM 24" BELOW GRADE TO WITHIN 3" TO 6" OF CAD -WELD TERMINATION POINT. THE EXPOSED END OF THE CONDUIT MUST BE SEALED WITH SILICONE CAULK. (ADD TRANSITIONING GROUND STANDARD DETAIL AS WELL). 21. BUILDINGS WHERE THE MAIN GROUNDING CONDUCTORS ARE REQUIRED TO BE ROUTED TO GRADE, THE CONTRACTOR SHALL ROUTE TWO GROUNDING CONDUCTORS FROM THE ROOFTOP, TOWERS, AND WATER TOWERS GROUNDING RING, TO THE EXISTING GROUNDING SYSTEM, THE GROUNDING CONDUCTORS SHALL NOT BE SMALLER THAN 2/0 COPPER. ROOFTOP GROUNDING RING SHALL BE BONDED TO THE EXISTING GROUNDING SYSTEM, THE BUILDING STEEL COLUMNS, LIGHTNING PROTECTION SYSTEM, AND BUILDING MAIN WATER LINE (FERROUS OR NONFERROUS METAL PIPING ONLY). 1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, NEC AND ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES/ORDINANCES. 2. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT BLOCKED AND TRIP HAZARDS ARE ELIMINATED. 3. WIRING, RACEWAY AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEC. 4. ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY THE NEC. 4.1. ALL EQUIPMENT SHALL BEAR THE UNDERWRITERS LABORATORIES LABEL OF APPROVAL, AND SHALL CONFORM TO REQUIREMENT OF THE NATIONAL ELECTRICAL CODE. 4.2. ALL OVERCURRENT DEVICES SHALL HAVE AN INTERRUPTING CURRENT RATING THAT SHALL BE GREATER THAN THE SHORT CIRCUIT CURRENT TO WHICH THEY ARE SUBJECTED, 22,000 AIC MINIMUM. VERYIFY AVAILABLE SHORT CIRCUIT CURRENT DOES NOT EXCEED THE RATING OF ELECTRICAL EQUIPMENT IN ACCORDANCE WITH ARTICLE 110.24 NEC OR THE MOST CURRENT ADOPTED CODE PRE THE GOVERNING JURISDICTION. 5. EACH END OF EVERY POWER PHASE CONDUCTOR, GROUNDING CONDUCTOR, AND TELCO CONDUCTOR OR CABLE SHALL BE LABELED WITH COLOR -CODED INSULATION OR ELECTRICAL TAPE (3M BRAND, 1/2" PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR EQUAL). THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC AND OSHA. 6. ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH LAMICOID TAGS SHOWING THEIR RATED VOLTAGE, PHASE CONFIGURATION, WIRE CONFIGURATION, POWER OR AMPACITY RATING AND BRANCH CIRCUIT ID NUMBERS (i.e. PANEL BOARD AND CIRCUIT ID'S). 7. PANEL BOARDS (ID NUMBERS) SHALL BE CLEARLY LABELED WITH PLASTIC LABELS. 8. ALL TIE WRAPS SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE SHARP EDGES. 9. ALL POWER AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE COPPER CONDUCTOR (#14 OR LARGER) WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 10. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE COPPER CONDUCTOR (#6 OR LARGER) WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 11. POWER AND CONTROL WIRING IN FLEXIBLE CORD SHALL BE MULTI -CONDUCTOR, TYPE SOOW CORD (#14 OR LARGER) UNLESS OTHERWISE SPECIFIED. 12. POWER AND CONTROL WIRING FOR USE IN CABLE TRAY SHALL BE MULTI -CONDUCTOR, TYPE TC CABLE (#14 OR LARGER), WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 13. ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP -STYLE, COMPRESSION WIRE LUGS AND WIRE NUTS BY THOMAS AND BETTS (OR EQUAL). LUGS AND WIRE NUTS SHALL BE RATED FOR OPERATION NOT LESS THAN 75° C (90° C IF AVAILABLE). 14. RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, ILL, ANSI/IEEE AND NEC. 15. ELECTRICAL METALLIC TUBING (EMT), INTERMEDIATE METAL CONDUIT (IMC), OR RIGID METAL CONDUIT (RMC) SHALL BE USED FOR EXPOSED INDOOR LOCATIONS. 16. ELECTRICAL METALLIC TUBING (EMT) OR METAL -CLAD CABLE (MC) SHALL BE USED FOR CONCEALED INDOOR LOCATIONS. 17. SCHEDULE 40 PVC UNDERGROUND ON STRAIGHTS AND SCHEDULE 80 PVC FOR ALL ELBOWS/90s AND ALL APPROVED ABOVE GRADE PVC CONDUIT. 18. LIQUID -TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED INDOORS AND OUTDOORS, WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. 19. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION -TYPE AND APPROVED FOR THE LOCATION USED. SET SCREW FITTINGS ARE NOT ACCEPTABLE. 20. CABINETS, BOXES AND WIRE WAYS SHALL BE LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND THE NEC. 21. WIREWAYS SHALL BE METAL WITH AN ENAMEL FINISH AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN DOWNWARDS (WIREMOLD SPECMATE WIREWAY). 22. SLOTTED WIRING DUCT SHALL BE PVC AND INCLUDE COVER (PANDUIT TYPE E OR EQUAL). 23. CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON -PERFORATED STRAPS AND HANGERS. EXPLOSIVE DEVICES (i.e. POWDER -ACTUATED) FOR ATTACHING HANGERS TO STRUCTURE WILL NOT BE PERMITTED. CLOSELY FOLLOW THE LINES OF THE STRUCTURE, MAINTAIN CLOSE PROXIMITY TO THE STRUCTURE AND KEEP CONDUITS IN TIGHT ENVELOPES. CHANGES IN DIRECTION TO ROUTE AROUND OBSTACLES SHALL BE MADE WITH CONDUIT OUTLET BODIES. CONDUIT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. PARALLEL AND PERPENDICULAR TO STRUCTURE WALL AND CEILING LINES. ALL CONDUIT SHALL BE FISHED TO CLEAR OBSTRUCTIONS. ENDS OF CONDUITS SHALL BE TEMPORARILY CAPPED FLUSH TO FINISH GRADE TO PREVENT CONCRETE, PLASTER OR DIRT FROM ENTERING. CONDUITS SHALL BE RIGIDLY CLAMPED TO BOXES BY GALVANIZED MALLEABLE IRON BUSHING ON INSIDE AND GALVANIZED MALLEABLE IRON LOCKNUT ON OUTSIDE AND INSIDE. 24. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES AND PULL BOXES SHALL BE GALVANIZED OR EPDXY -COATED SHEET STEEL. SHALL MEET OR EXCEED UL 50 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND NEMA 3R (OR BETTER) FOR EXTERIOR LOCATIONS. 25. METAL RECEPTACLE, SWITCH AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY -COATED OR NON -CORRODING; SHALL MEET OR EXCEED UL 514A AND NEMA OS 1 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WP OR BETTER) FOR EXTERIOR LOCATIONS. 26. NONMETALLIC RECEPTACLE, SWITCH AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2 (NEWEST REVISION) AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WP OR BETTER) FOR EXTERIOR LOCATIONS. 27. THE CONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE CARRIER AND/OR CROWN CASTLE USA INC. BEFORE COMMENCING WORK ON THE AC POWER DISTRIBUTION PANELS. 28. THE CONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES AND DISTRIBUTION PANELS IN ACCORDANCE WITH THE APPLICABLE CODES AND STANDARDS TO SAFEGUARD LIFE AND PROPERTY. 29. INSTALL LAMICOID LABEL ON THE METER CENTER TO SHOW "AT&T". 30. ALL EMPTY/SPARE CONDUITS THAT ARE INSTALLED ARE TO HAVE A METERED MULE TAPE PULL CORD INSTALLED. CONDUCTOR COLOR CODE SYSTEM CONDUCTOR COLOR 120/24OV, 10 A PHASE BLACK B PHASE RED NEUTRAL WHITE GROUND GREEN 120/208V, 30 A PHASE BLACK B PHASE RED C PHASE BLUE NEUTRAL WHITE GROUND GREEN 277/48OV, 30 A PHASE BROWN B PHASE ORANGE OR PURPLE C PHASE YELLOW NEUTRAL GREY GROUND GREEN DC VOLTAGE POS (+) RED** NEG (-) BLACK** * SEE NEC 210.5(C)(1) AND (2) ** POLARITY MARKED AT TERMINATION ABBREVIATIONS: ANT ANTENNA (E) EXISTING FIF FACILITY INTERFACE FRAME GEN GENERATOR GPS GLOBAL POSITIONING SYSTEM GSM GLOBAL SYSTEM FOR MOBILE LTE LONG TERM EVOLUTION MGB MASTER GROUND BAR MW MICROWAVE (N) NEW NEC NATIONAL ELECTRIC CODE (P) PROPOSED PP POWER PLANT QTY QUANTITY RECT RECTIFIER RBS RADIO BASE STATION RET REMOTE ELECTRIC TILT RFDS RADIO FREQUENCY DATA SHEET RRH REMOTE RADIO HEAD RRU REMOTE RADIO UNIT SIAD SMART INTEGRATED DEVICE TMA TOWER MOUNTED AMPLIFIER TYP TYPICAL UMTS UNIVERSAL MOBILE TELECOMMUNICATIONS SYSTEM W.P. WORK POINT APWA UNIFORM COLOR CODE: WHITE PROPOSED EXCAVATION TEMPORARY SURVEY MARKINGS ELECTRIC POWER LINES, CABLES, CONDUIT, AND LIGHTING CABLES YELLOW GAS OIL, STEAM, PETROLEUM, OR GASEOUS MATERIALS ®COMMUNICATION, ALARM OR SIGNAL LINES, CABLES, OR CONDUIT AND TRAFFIC LOOPS POTABLE WATER RECLAIMED WATER, IRRIGATION, AND SLURRY LINES SEWERS AND DRAIN LINES AT&T 575 MOROSGO DRIVE ATLANTA, GA 30324-3300 C%fto CROWN C.A�T L E 3530 TORINGDON WAY, SUITE 300 CHARLOTTE, NC 28277 AT&T SITE NUMBER: CV385 BU #: 842588 TOMLIN 1052 GOODWIN FARM LANE CHARLOTTESVILLE, VA 22903 EXISTING 105'-0" MONOPOLE ISSUED FOR: REV 11 DATE DRWN DESCRIPTION DES./Q 0 07/01/20 NH CONSTRUCTION MAM 07/07/20 AK CONSTRUCTION MAM 2 09/08/20 AK CONSTRUCTION MAM 3 12/02/20 CV CONSTRUCTION MAM by: WAGED ABDEL-MESSIH Uc. No. 49004 Crown Castle USA Inc. COA #407005050 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: T-2 3 DocuSign Envelope ID: E8E41141-C22B-42DF-A957-564715F8CC8F DocuSign Envelope ID: E8E41141-C22B-42DF-A957-564715F8CC8F (E) 105'-0" MONOPOLE + (E) AT&T ICE BRIDGE + t6'-0" + + + + (E) AT&T ICE BRIDGE U t6'-0" \\ + (E) 105'-0" MONOPOLE r■ + + + (E) AT&T GPS ANTENNA (TYP) (E) FEEDLINES TREMAIN COAX \ + (1) COAX CABLE (3/8") (12) COAX CABLES (7/8") (E) AT&T TRIPLEXER + COMMSCOPE — CBC71921—DF-2X (6 TOTAL) + + + + + (E) AT&T RRH TO BE REMOVED + + ERICSSON — RRUS 11 (3 TOTAL) (E) AT&T 12'-0"x12'—O" + AREA (E) AT&T FLEX 16 + V CABINET + + / + (E) AT&T RRH + + ERICSSON — RRUS 32 B2 (3 TOTAL) (E) AT&T / EMERSON BATTERY /� (E) AT&T TELCO BER CABINET / / JUNCTION \FIBOX + 0 (EAT&T DC POWER JUNCTION BOX (E) AT&T / + EMERSON 512 / (E) AT&T PP / UTILITY FRAME (E) AT&T ICE BRIDGE / t9'-0" / (E) AT&T STACKED PURCELL CABINETS (E) AT&T 8'-6"x 10'-0" EQUIPMENT PAD (E) AT&T ICE BRIDGE + + ±6'-0" + + (N) AT&T FEEDLINE fi (1) 24 PAIR FIBER CABLE (3/8") + 0 (E) AT&T ICE BRIDGE + + t6'—O" + (N) AT&T EQUIPMENT: + (1) 6630 (N) AT&T EQUIPMENT: (4) 170AH BATTERIES (N) AT&T FEEDLINE (1) #8AWG DC CABLE (3/4") (N) AT&T EQUIPMENT: (4) —48VDC RECTIFIERS (3) 40A BREAKERS (3) 30A BREAKERS (3) VERTIV UP CONVERTERS EXISTING EQUIPMENT PLAN + + (E) AT&T GPS ANTENNA (TYP) (E) FEEDLINES + COAX \ + (1) COAX CABLE (3/8°) (12) COAX CABLES (7/8") T (E) AT&T TRIPLEXER + COMMSCOPE — CBC71921—DF-2X (6 TOTAL) + + + + \ (E) AT&T EMERSON BATTERY CABINET (E) AT&T + + + \ (E) AT&T FIBER \ SLACK BOX �(E) AT&T POWER SLACK BOX (E) AT&T DC12 ■r (E) AT&T ICE BRIDGE t 18'-0" v NA T T RRH ) & :RICSSON — RRUS 4426 B66 3 TOTAL) (E) AT&T 12'-0"x12'—O" AREA (N) AT&T RRH ERICSSON — RRUS 4449 B5/B12 (3 TOTAL) (E) AT&T FIBER + \ SLACK BOX + (E) AT&T POWER �CK BOX (E) AT&T DC12 QMILIMM (E) AT&T ICE BRIDGE t 18'-0" EMERSON 512 / (E) AT&T PP / UTILITY FRAME (E) AT&T ICE BRIDGE / ±9'-0" / (E) AT&T STACKED PURCELL CABINETS (E) AT&T 8'-6"x 10'-0" EQUIPMENT PAD FINAL EQUIPMENT PLAN v GROUND SCOPE OF WORK: *POWER ANALYSIS FAILED -INSTALL (3) EMERSON —48V RECTIFIERS IN EXISTING 512 POWER PLANT -INSTALL (3) 40 AMP DC BREAKERS FOR PROPOSED 4449 RRU's *INSTALL (3) 30 AMP DC BREAKERS FOR PROPOSED 4426 RRU's *INSTALL (3) VERTIV UP CONVERTERS FOR PROPOSED 4478 RRU's -INSTALL (4) 170 AMP BATTERIES IN EXISTING BATTERY CABINET -INSTALL (1) 6630 IN EXISTING FLEX 16 *REMOVE (3) RRUS11 B12 FROM OUTDOOR H FRAME *INSTALL (3) 4449 35/1312 ON OUTDOOR H FRAME *INSTALL (3) 4426 ON OUTDOOR H FRAME NOTE: THE POWER DESIGN FOR ANY AC ELECTRICAL POWER CHANGES IS TO BE PERFORMED BY OTHERS AND IS SHOWN HERE FOR REFERENCE PURPOSES ONLY. AT&T IS SOLELY RESPONSIBLE FOR THE ELECTRICAL POWER DESIGN. r AT&T 575 MOROSGO DRIVE ATLANTA, GA 30324-3300 - CROWN v C.AT L E 3530 TORINGDON WAY, SUITE 300 CHARLOTTE, NC 28277 AT&T SITE NUMBER: CV385 BU #: 842588 TOMLIN 1052 GOODWIN FARM LANE I CHARLOTTESVILLE, VA 22903 EXISTING 105'-0" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q 0 07/01/20 NH CONSTRUCTION MAM 1 07/07/20 AK CONSTRUCTION MAM 2 09/08/20 AK CONSTRUCTION MAM 3 12/02/20 CV CONSTRUCTION MAM p, L by: MAGED ABDEL—MESSIH Lic. No. 49004 5 : 5 7 Crown Castle USA Inc. COA #407005050 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: C-1 .2 3 DocuSign Envelope ID: E8E41141-C22B-42DF-A957-564715F8CC8F STRUCTURE W/ APPURTENANCE ELEV. = 107'-0" TIP OF ANTENNA ELEV. = 105'-0" HEIGHT OF STRUCTURE ELEV. = 105'-0" ACROSS FLATS (1 '— ELEV. = 101'-0" FINAL ELEVATION SCALE: NOT TO SCALE EXISTING AT&T ACL/MCL OL ELEV. = 101'-0" (N) AT&T EQUIPMENT (6) ANTENNAS (3) RRUs (1) SQUID (3) T—ARM MOUNTS (1) 2-1/2" SCH. 40 x 6'-0" LONG GALV. PIPE W/ CROSSOVER HARDWARE (E) 105'-0" MONOPOLE (E) AT&T FEEDLINES (1) COAX CABLE (3/8") (12) COAX CABLES (7/8") (ROUTED PER STRUCTURAL ANALYSIS) (N) AT&T FEEDLINES (1) #8AWG DC CABLES (3/4") (1) 24 PAIR FIBER CABLE (3/8") (ROUTED PER STRUCTURAL ANALYSIS) (GAMMA) 330` AZIMUTH (E) AT&T ANTENNA TO BE REMOVED CCI ANTENNAS — TPA-65R—LCUUUU—H6—K (3 TOTAL, 1 PER SECTOR) (E) AT&T TMA TO BE RELOCATED COMMSCOPE — E15Z01P39 (6 TOTAL, 2 PER SECTOR) 31 (BETA) 215' AZIMUTH f C1 EXISTING ANTENNA PLAN SCALE (N) AT&T 2-1/2" SCH. 40 x 6'-0" LONG GALV. PIPE W/ CROSSOVER HARDWARE (1 TOTAL) C1 (N) AT&T SQUID RAYCAP — DC9-48-60-24-8C—EV (1 TOTAL) (N) AT&T ANTENNA COMMSCOPE — NNH4-65B—R6N17 i (6 TOTAL, 2 PER SECTOR) (GAMMA) 330° AZIMUTH B3 \ �< 7(BETA) 215` AAZIMUTH f 31 FINAL ANTENNA PLAN 0 (E) PIPE MOUNT TO BE REMOVED (3 TOTAL) (E) 105'-0" MONOPOLE C3 f Al (ALPHA) 110° AZIMUTH i A3 (N) AT&T RRH ERICSSON — RRUS 4478 B14 (3 TOTAL, 1 PER SECTOR) (N) AT&T CUSTOM T—ARM MOUNT KENWOOD — Z2058KT8-9114—M (3 TOTAL, 1 PER SECTOR) (E) AT&T TMA RELOCATION COMMSCOPE — E15ZO1P39 (6 TOTAL, 2 PER SECTOR) Al (ALPHA) 110' AZIMUTH m "LOOK UP" — CROWN CASTLE USA INC. SAFETY CLIMB REQUIREMENT: THE INTEGRITY OF THE SAFETY CLIMB AND ALL COMPONENTS OF THE CLIMBING FACILITY SHALL BE CONSIDERED DURING ALL STAGES OF DESIGN, INSTALLATION, AND INSPECTION. TOWER MODIFICATION, MOUNT REINFORCEMENTS, AND/OR EQUIPMENT INSTALLATIONS SHALL NOT COMPROMISE THE INTEGRITY OR FUNCTIONAL USE OF THE SAFETY CLIMB OR ANY COMPONENTS OF THE CLIMBING FACILITY ON THE STRUCTURE. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO: PINCHING OF THE WIRE ROPE, BENDING OF THE WIRE ROPE FROM ITS SUPPORTS, DIRECT CONTACT OR CLOSE PROXIMITY TO THE WIRE ROPE WHICH MAY CAUSE FRICTIONAL WEAR, IMPACT TO THE ANCHORAGE POINTS IN ANY WAY, OR TO IMPEDE/BLOCK ITS INTENDED USE. ANY COMPROMISED SAFETY CLIMB, INCLUDING EXISTING CONDITIONS MUST BE TAGGED OUT AND REPORTED TO YOUR CROWN CASTLE USA INC. POC OR CALL THE NOC TO GENERATE A SAFETY CLIMB MAINTENANCE AND CONTRACTOR NOTICE TICKET. INSTALLER NOTES: 1. REFERENCE C-3 FOR FINAL EQUIPMENT SCHEDULE. 2. REFERENCE C-4 FOR NEW EQUIPMENT SPECIFICATIONS. 3. CONTRACTOR TO VERIFY ALL ANTENNA TIP HEIGHTS DO NOT EXCEED BEACON BASE HEIGHT. 4. 3'-0" MINIMUM DISTANCE REQUIRED BETWEEN LTE ANTENNAS ON SAME SECTOR. 5. 6'-0" MINIMUM DISTANCE REQUIRED BETWEEN 70OBC & 700DE ANTENNAS ON SAME SECTOR. 6. 4'-0" MINIMUM DISTANCE REQUIRED BETWEEN LTE 700 ANTENNAS ON OPPOSING SECTORS. 7. ALL ANTENNA MEASUREMENT DISTANCES MUST BE EDGE TO EDGE (RELOCATE ANTENNAS AS NEEDED). 8. 8" MINIMUM DISTANCE REQUIRED BETWEEN ANTENNA & RADIO. SEE GENERIC EXAMPLE DETAIL ON SHEET C-4. 9. NO PROPOSED LOADING TO BE ADDED UNTIL MOUNT SWAP IS COMPLETE. CONTRACTOR TO INSTALL MOUNT PER MANUFACTURER'S 10. NEW EQUIPMENT TO BE PAINTED WITH RF TRANSPARENT, UV RESISTANT, OUTDOOR RATED PAINT TO MATCH EXISTING. AT&T 575 MOROSGO DRIVE ATLANTA, GA 30324-3300 - CROWN v C.AT L E 3530 TORINGDON WAY, SUITE 300 CHARLOTTE, NC 28277 AT&T SITE NUMBER: CV385 BU #: 842588 TOMLIN 1052 GOODWIN FARM LANE CHARLOTTESVILLE, VA 22903 EXISTING 105'-0" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q 0 07/01/20 NH CONSTRUCTION MAM 1 07/07/20 AK CONSTRUCTION MAM 2 09/08/20 AK CONSTRUCTION MAM 3 12/02/20 CV CONSTRUCTION MAM y; T H OF`A..pp a Q(oau—I141,Ssi 43162EA13481 " MAGED ABDEL—MESSIH v Uc. No. 49004 12/2 �O�/VNA7L�ST Crown Castle USA Inc. COA #407005050 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: -2 3 DocuSign Envelope ID: E8E41141-C22B-42DF-A957-564715F8CC8F DocuSign Envelope ID: E8E41141-C22B-42DF-A957-564715F8CC8F urv., ., ",, I , . . ET INUFACTURER'S SPECIFICATIONS) JMPER CONNECTION (TYP) IN MIN BEND RADIUS PER 4CTURER'S SPECIFICATIONS NEW RRH TO BE INSTALLED BEHIND ANTENNA (TYP) REFER TO RF SHEET FOR QUANTITY & LOCATION NEW JUMPER FROM RAYCAP MAINTAIN MIN BEND RADIUS PER MANUFACTURER'S SPECIFICATIONS .,.,I.I I..,- , ,..,I.I I.I., I i0 ANTENNA GENERIC ANTENNA MOUNTING ELEVATION SCALE: NOT TO SCALE � re= ERICSSON — RRUS 4426 B66 WEIGHT: 60.0 LBS SIZE (HxWxD): 14.9x13.2x5.8 IN. ERICSSON - RRUS 4426 B66 SCALE: NOT TO SCALE COMMSCOPE — NNH4-65B—R6N17 WEIGHT (FULLY EQUIPPED): 82.0 LBS SIZE (HxWxD): 72.Ox19.6x7.8 IN. CONNECTOR TYPE: 4.3-10 FEMALE (12 TOTAL PORTS) COMMSCOPE - NNH4-65B-R6N17 SCALE: NOT TO SCALE ERICSSON — RRUS 4478 B14 WEIGHT: 60.0 LBS SIZE (HxWxD): 15.0x13.0x8.0 IN. ERICSSON - RRUS 4478 B14 SCALE: NOT TO SCALE O - o' ERICSSON — RRUS 4449 B5/1312 WEIGHT: 70.0 LBS SIZE (HxWxD): 18.0x13.2x9.4 IN. ERICSSON - RRUS 4449 35/B12 SCALE: NOT TO SCALE in )A" RAYCAP — DC9-48-60-24-8C—EV WEIGHT (WITHOUT MOUNTING HARDWARE): 16.0 LBS SIZE (HxWxD): 31.4x10.24x18.28 IN. RAYCAP - DC9-48-60-248C-EV SCALE: NOT TO SCALE iiz AT&T 575 MOROSGO DRIVE ATLANTA, GA 30324-3300 - CROWN v C.AT L E 3530 TORINGDON WAY, SUITE 300 CHARLOTTE, NC 28277 AT&T SITE NUMBER: CV385 BU #: 842588 TOMLIN 1052 GOODWIN FARM LANE CHARLOTTESVILLE, VA 22903 EXISTING 105'-0" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q 0 07/01/20 NH CONSTRUCTION MAM 1 07/07/20 AK CONSTRUCTION MAM 2 09/08/20 AK CONSTRUCTION MAM 3 12/02/20 CV CONSTRUCTION MAM ------------- MAGED ABDEL—MESSIH Uc. No. 49004 5 : 5 7 : Crown Castle USA Inc. COA #407005050 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: C-4 3 DocuSign Envelope ID: E8E41141-C22B-42DF-A957-564715F8CC8F STEP 2: ENTER DC PLANT TYPE FROM ORO P-DOWN MENU: ('GENERIC" +24V or -48VDC PLANT CAN BESELECTED FOR AN YMANUFACTURER'S DC PLANT) . ...... .. ��.� u .. n n o u u u u .. u n u u.� u u u u u u u n n u n u u u u u�• u u u u u u u u n u u u u u �. u n (DC PLANT CONFIGURATION CAN BE REVIEWED ON DC PLANT WORKSHEET) STE P 2A: THIS STEP ONLY SHOWN IF 'rGENERIC'DC PLANTPLANT TYPE HAS BEEN SELECTED: :iTEP 28: THIS STEP OHLY SHOWN IF TYCO GPS24240C PLANTPLANT TYPE HAS BEEN SELECTED: STEP 3: DO YOU WANT TO CONFIGURE A STANDARD STAND-ALONE OC CONVERTER SYSTEM? N NOTE: IF YOU SELECT "Y'ANYINTEGRATED DC PLANT CONVERTER OPTIONSV ILL BE BYPASSED MIA STEP4: ENTER INDOOR SIT EBUILDINGrSHELTERDATA: (Square footage used for interior AC lighting LOAD calculation) SELECT SITE BUILDING TYPE &SIZE STEP 5: ENTER SITE HVAC SYSTEMDATA: SPECIFY INDIVIDUAL HVAC UNIT SIZE (TONS SPECIFY QUANTITY DO ES SITE HAVE AD DITI ON AL H VAC (DI F FE RE N T S IZE) N ARE THERE SITE HVAC HEATING UNITS N TOTAL SPECIFIED SITE HVAC ESTIMATED HVAC REQUIREMENT TWO 3-TON UNITS SPECIF IE D HVAC 110 T SUFFICIENT THIS TOOL DOES NOT APPLY TO SITE S THAT ARE FOU IPPFD WITH FREE STA14DING D IRE CT AIR COOLING STEP 6: ENTER SITE STATIONARY GENERATOR DATA: _ DOES SITE HAVE A STATIONARY GE HE RATOR? 11 ESTIMATED CAPACITY REQUIRED 1 23 KW (NO SITE GENERATOR) STEP 7: SPECIFY TOTAL QUANTITY OF BATTERY STRING 5 TOTAL SITE BATTERY CAPACITY (AH) 850 NOTE: STANDARD BATTERY CAPACITY HAS BEEN SPECIFIED NOTE: 12 VOLT MONO BLOCK BATTERIES - 4 batteries per 48V String ESTIMATED BATTERY RESERVE TIMEJ 4.38 1HOURS1 QIOSITE GENSE7) SITES WITH STATIONARY GENSETS SHALL BE ENGINEERED YNTH AMAK OF 3 SHELVES of 180 AH BATT ERIES (3strings at-48Yor6strings at+24v)-ALL OTHER SITES AMINIMUM OF 4HOURS ANY QUESTIONS PLEASE CONTACT RICK BADGE PO (RB6620CATT.COK THIS POWER ESTIMATE WORKSHEET HAS BEEN PROVIDED BY OTHERS AND IS SHOWN HERE FOR REFERENCE PURPOSES ONLY. CROWN CASTLE USA INC. DOES NOT GUARANTEE THE ACCURACY OF THE INFORMATION FOUND IN THIS WORKSHEET. QTY I RADIOHEAID S-Outdoor VOLTAGE I VuATTS QTY Ericsson 0 0 R RUS 01 B2, B5 (8UJ10 48 1 0 0 Q IR RUS 01 012 (WIP0 48 0 0 R RUS 11 612 (2(300J) 48 0 0 R RUS 1102. B4, B5, Ell (2x4UVV) 48 0 0 R RUS 12 B2, B4, B5 (26MNO 48 0 3 R RUS 32 B2 (4x40M 48 2049 0 R RUS 32 B30 (4x25W) 48 0 0 IR RUS 32 B66A 48 0 0 R RUS A2 B2, B4, B12 48 0 0 R RUSE2 B29 48 0 3 R RUW B2 , BS 48 816 0 AIR 21 (60W) 48 0 3 P, RUS 4478 814 48 1560 0 14X4b tUbbA 48 0 0 FDDRRH2x40-07L(UHLA)B17 48 0 0 RRH2x40-07L-AT (UHLB)817 48 0 0 625 R RH4x30 (UHFA) E25 48 0 0 B25 R RH2x60 (UHFA) E25 48 0 0 2XISM-850 B5 48 0 0 2X6M-1900 B2 48 0 0 2X60W-1900A B2 48 0 0 N0 RRH2x40-07L-0DE (UHLC) B29 48 0 0 R RH 4T4R (FRBI) B14 48 0 RRH4X25 B30 48 0 QTY I KAUIO HLAUS -Indoor I VOLTAGE 1 VyATTS I 0 IK KUti U1 H2, BS (UNV) 48 0 0 RRUS 01 B12 (60M 48 0 0 R RUS 11 B12 (2(3MAD 48 0 0 R RUS 11 B2, B4, E15, 812 (2x40W) 48 0 0 R RUS 12132, 84. 85 (2x6D M 48 0 0 R RUS 32 82 (4x40M 48 0 o R PUS 32 B30 (4x25W) 48 0 0 R RUS 32 B66A 48 0 0 R RUS A2 B2, B4, Ell 48 0 0 RRUSE2B29 48 0 0 R RUIN 82, BS 48 0 0 AIR 21 (150M 48 0 0 R RUS 4478 El 1 48 0 0 14X45 t:JbbA 48 0 0 FDD RRH2x40-07L(UHLA) 817 48 0 0 RRH2x40-07L-AT (UHLB)B17 48 0 0 825 R RH4x30 (UHFA) B25 48 0 0 625 R RH2x60 (UHFA) B25 48 0 0 2X60VV-850 65 48 0 0 2X60W-1900 B2 48 0 0 2XISOW-1900A B2 48 0 0 RRH2x40-07L-0DE (UHLC) 829 48 0 0 R RH 4T4R (FRBI) B14 48 0 0 RRH4Y25 B30 48 0 110 ricssonLTE IRBS6601 BBU- 1 DUL 0 ricsson LTE RBS6601 BBU - 2 DUL 1 ricssonWJCDMARBS6601 -1 DUW 0 ricsson LTE RBS6601 BBU -1 DU S 0 ricsson LTE RBS6601 BB - 2DU S riemn )(MU 1 Fricss3on LTE RBS5216 VOLTAGE V-ATTS QTY 48 0 0 4a 0 ■ii� Ir' MI�+ Yip'' r f", W 0 Cisco WAR-2941 SIAD 0 0 Cisco SIAD ASR-901 232 0 Cisco 15310 EOS (SONET) N11_I:v: 0 0 Cisco 15454 MSP (MW Ring Con 0 40 0 Tru-PasitionLMU (E911) QTY UMTS 3G EQUIPMENT148 -OTT' 0 LU MACRO NodeB (3S1 C - 40M 0 0 LU MACRO NodeB (3S2C - AIGM 0 p LU MACRO NodeB (3S3C - 40UV) p 0 LU MACRO NodeB (3S4C - 40M 0 0 LU MACRO NodeB (3S5C - 40W - 2 CA 0 0 LU MICRO NodeB 0 0 LU 9396 d2U Distributed NodeB MU 0 0 LU 9396 d4U Distributed NodeB MU 0 0 rir:=rin RBS3206 NodeB 3S1C -1 CAB 1 24 0 0 ric:-:-=-1n RBE3206 NodeB 3S2C -1 CAB 1 24 0 NON-0BIF Ericsson 3rd, 4th& 5th Carrier 0 ricsson RBS3206 NodeB 3S3C - 2 CAB 24 0 0 ricmn RBS3206 NodeB 3S4C - 2 CAB 24 0 0 ricsson RBS3206 NodeB 3S5C - 3 CAB 24 0 0BIF Ericsson 3rd, 41h & 5th Carrier 0 ncsson RBS3206 NodeB 3S3C - 1 CAP ,,,,,,,,,,,,,,,,,,,,,,,, ,..... .,.. (Select RR US from left sedi on) 0 ricsson RBS3206 NodeB 3S4C - 1 CAB ,,,,,,,,,,,,,,,,,,,,,1..... .... ,,..,,..,...... , . .,, (Select RR US from left sedi on) Re ricsson RBS3206 NodeB 3S4C - 1 CAB (Select RRUS from left sedi on) 0 rics On RBS3206 NodeB 3S5C - 2 CAB (Select US RRfrom left secti on) 24 0 0 ricmn 3303 MICRO NodeB 24 0 0 ricsson RBS3418 Didrlbuted NodeB MU 48 0 QTY USER SPECIFIED AC EQUIPMENT VOLTAGE KVA 0 enBateryCharger 120 0 IQTY 0 en Heater 120 0 0 FCI 120 0 0 esa Cabinet 120 0 0 Cabinet 120 0 720 0 S3106 240 0 JReel 2106 240 0 -02 240 0 5 batter;,rnat:_ 120 0 TOTALUSER SPECIFIED OTAI 1?QVAC APr1PS: 0 0 KVA 0 -4BV PRIMARY VOLTAGE DC PLANT SPECIFIED +24VOCEQUIPMENT LOAD: 0 WATTS =I -48VDC E QUIPN E NT LOAD: 15156 WATTS = 0 AMPS at+2411 281 AMPS at -48V NOSE CONDARV 24VLOADS -DC CONVERTERSVSTEM NOT REQUIRED TOTAL PRIMARY 48V LOAD: 15156 WATTS = 1 281 AMPS at -48V DC PLANT: Emerson STD 48VDC Outdoor NetSure 512 System525A NEQ.15917 -48V RECTUIERS REQUIRED (W-114 48V RECTIFIER SLOTS: 10 16 CONV. TYPE: MA +24V CONVERTERS REQUIREDH12 +24V CON VE RTE R SLOTS(NODCCONVERTERSREQUIRED) (NODCCONVERTERSREQUIRED) ESTIMATED BATTERY RESERVE TIME 5170AH48VSTRINGS= 4.38 HOURS (4HOURMINIMUM BATTERY RESERVE) POWER ANALYSIS SCALE: NOT TO SCALE 0 JDC Free Air (per HVAC unit) 1 GENERIC Ethernet NID 0 GENERICHydrogenDetector 0 GENERIC RET Controller 0 GENERIC RMA1T 0 GENERIC Smoke Detector 0 GENERICTMASystem 0 GENERIC Tovter Lighting (DC D ING480 lUPMENT VOLTAGEROTS 48 tch - MSS 48 Unit - OD U 48 48 48 Z 48 48 48 48 24 24 48 48 48 40 0 0 0 0 0 60 0 0 0 0 0 0 0 err' TX RF AMP QACPA or SCPA) E QPT. VOLTAGE v1TTs 0 Andrew(12 module mcpa FRAME) 24 0 0 Andrew 135We1tModule 24 0 0 Po%Aerv�Qve 12 modul a mcpa FRAME) 24 0 D PovAerv�ve90Watt MOdule 24 0 0 Povuervkave 120 Waft Module 24 0 0 Povaer+nave 160 Watt Module 24 0 0 CC 125 Watt DA8 SCPA Module 24 0 0 CC 125 Watt DA.0 SCPA Module 24 0 QTY USE RSPECIFIEDDCEQUIPMENT VOLTAGE WATTS 0 RRU 4415B25 48 0 0 RRU 4415B30 48 0 3 RRU 4426B66 48 2427 3 RRU 4449B5)B12 48 4320 0 jR.RL1 8843B2666 48 0 0 RRU 22 UMTS 48 0 1 r-633 BBU 48 180 0 ,-'MM 20p B 48 0 0 AmpLink GMA 48 0 1 S9500 SIAD single PSU 48 330 0 SDARS Remote 48 0 0Flex MU W 3 OTRX 48 0 1 12 48 520 JION 2 Flex 16 48 2390 0 Flex 21 48 0 TOTAL USER SPECIFIED TOTAL -48V (54V) AMPS: WATTS n 180.3 ESTIMATED SITE MAX AC LOAD (AkWS):l 102.08 AMPS ESTIMATE 200A SERVICE SUFFICIENT SITE GENERATOR CAPACITY REQUIRED: 23 KW ON SITE G E HE RATO R CAPACITY10 KW (NO ONSRE GENERATOR) RECOMMENDED HVACSYSTE TWO 3-TON SPECIFIED SITE TOTAL HVAC CAPACITY I 0-TONS ESTIMATE EXISTING HVACNOT SUFFICIENT iiz AT&T 575 MOROSGO DRIVE ATLANTA, GA 30324-3300 - CROWN v C.AT L E 3530 TORINGDON WAY, SUITE 300 CHARLOTTE, NC 28277 AT&T SITE NUMBER: CV385 BU #: 842588 TOMLIN 1052 GOODWIN FARM LANE CHARLOTTESVILLE, VA 22903 EXISTING 105'-0" MONOPOLE ISSUED FOR: REV 11 DATE DRWN DESCRIPTION DES./Q 0 07/01/20 NH CONSTRUCTION MAM 07/07/20 AK CONSTRUCTION MAM 2 09/08/20 AK CONSTRUCTION MAM 3 12/02/20 CV CONSTRUCTION MAM by: MAGED ABDEL-MESSIH Lic. No. 49004 Crown Castle USA Inc. COA #407005050 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: E-1 3 DocuSign Envelope ID: E8E41141-C22B-42DF-A957-564715F8CC8F DocuSian Envelooe ID: E8E41141-C22B-42DF-A957-564715F8CC8F TO ANTENNA COAX TO ANTENNA COAX WIRE SIZE BURNDY LUG BOLT SIZE COPPER/GALVANIZED GROUND BAR COPPER/GALVANIZED GROUND BAR #6 GREEN INSULATED YA6C-2TC38 3/8"— 16 NC SS 2 BOLT #2 SOLID TINNED YA3C-2TC38 3/8"— 16 NC SS 2 BOLT 0 0 0 00000000000000 0 0 0000000000000 #2 STRANDED YA2C-2TC38 3/8" — 16 NC SS 2 BOLT 0 0 0 00000000000000 0 0 0000000000000 #2/0 STRANDED YA26-2TC38 3/8" — 16 NC SS 2 BOLT o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 #4/0 STRANDED YA28-2N 1/2" — 16 NC SS 2 BOLT #2 SOLID TINNED COPPER CONDUCTOR TO TOWER/SHELTER BURNDY GROUND LUG W/ LONG BARREL HEAT SHRINK TWO HOLE LONG BARREL COMPRESSION LUG GROUND RING (2 TYP. FOR (SEE CHART) (CLEAR) TWO HOLE LONG BARREL BOTTOM GROUND BAR ONLY) COMPRESSION LUG (TYP) (TYP) LOCK WASHER T(TYP) �� A NOTES: 1. DOUBLING UP "OR STACKING" OF CONNECTIONS IS NOT PERMITTED. 2. EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS. 3. GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO ANTENNA MOUNT STEEL. ANTENNA SECTOR GROUND BAR DETAIL SCALE: NOT TO SCALE #6 MIN. FROM ANTENNA CABLE GROUND KIT GROUND BAR ON SHELTER. ICE BRIDGE, OR ON ANTENNA TOWER OID TWO HOLE LUG, OR EXOTHERMIC WELD TO BE USED WITH #2 BARE CONDUCTOR WIRE TO BUILDING SERVICE GROUND OR GROUND RING GROUNDWIRE INSTALLATION SCALE: NOT TO SCALE ANTENNA CABLE #6 STRANDED COPPER GROUND WIRE (GROUND TO GROUND BAR) SEE NOTES 1 & 2 GROUNDING SHALL BE ELIMINATED WHEN GROUND BAR IS ELECTRICALLY BONDED TO METAL TOWER (TYPICALLY) 12" TO 24" 120" MAX. NOTES: 1. EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS. 2. GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO TOWER STEEL (TOWER ONLY). 3. GROUND BAR SHALL BE ISOLATED FROM BUILDING OR SHELTER. TOWER/SHELTER GROUND BAR DETAIL SCALE: NOT TO SCALE GROUND CONDUCTOR GROUND BAR BOLT (SEE CHART) BURNDY TWO HOLE LUG (TYP) W/ LONG BARREL (SEE CHART) BARE WIRE TO BE TREATED WITH NO—OX AT BOTH ENDS AT&T 575 MOROSGO DRIVE ATLANTA, GA 30324-3300 i - CROWN v C.AT L E 3530 TORINGDON WAY, SUITE 300 CHARLOTTE, NC 28277 NOTE: STRANDED ALL GROUNDING LUGS ARE TO BE ® (SEE CHART) INSTALLED PER MANUFACTURER'S AT&T SITE NUMBER: CV385 SPECIFICATIONS. ALL HARDWARE 3/8-11x1" TAMPER BOLTS, NUTS, LOCK WASHERS SHALL RESISTANT BOLT BE STAINLESS STEEL. ALL HARDWARE (TYP) ARE TO BE AS FOLLOWS: BOLT, FLAT BU #: 842588 WASHER, GROUND BAR, GROUND SEE NOT 2 LUG, FLAT WASHER AND NUT. T OMLIN � (TYP) WALL BRACKET ® ® MECHANICAL LUG CONNECTION 1052 GOODWIN FARM LANE (TYP) ® ® 3 SCALE: NOT TO SCALE CHARLOTTESVILLE, VA 22903 o ® ® o ® EXISTING 105'-0" MONOPOLE ® UNIVERSAL COPPER O 0 ® ® GROUND BAR (4"x20") STAINLESS STEEL BOLT LOCK WASHER (TYP)P/N M 10 (TYP) STAINLESS STEEL TWO —HOLE FLAT WASHER COMPRESSION LUG 2—HOLE CRIMP/ (TYP) COMPRESSION CONNECTOR , WEATHERPROOFING KIT (SEE NOTE 3) Z X JUMPER TO ANTENNA CABLE CONNECTOR WEATHERPROOFING KIT (SEE NOTE 3) CABLE GROUND KIT NOTES: 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. 2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER. 3. WEATHER PROOFING SHALL BE TWO—PART TAPE KIT, COLD SHRINK SHALL NOT BE USED. CABLE GROUND KIT CONNECTION SCALE: NOT TO SCALE NOTES 1. DOWN LEAD (HOME RUN) CONDUCTORS ARE NOT TO BE INSTALLED ON CROWN CASTLE USA INC. TOWER, PER THE GROUNDING DOWN CONDUCTOR POLICY QAS—STD-10091. NO MODIFICATION OR DRILLING TO TOWER STEEL IS ALLOWED IN ANY FORM OR FASHION, CAD —WELDING ON THE TOWER AND/OR IN THE AIR ARE NOT PERMITTED. 2. OMIT INSULATOR WHEN MOUNTING TO TOWER STEEL OR PLATFORM STEEL USE INSULATORS WHEN ATTACHING TO BUILDING OR SHELTERS. GROUND BAR DETAIL SCALE: NOT TO SCALE NOTE: MINIMUM OF S/S NUT 3 THREADS TO BE (TYP) VISIBLE (TYP) S/S SPLIT WASHER 2 HOLE LONG (TYP)SOLID BARREL TINNED COPPER LUG S/S FLAT (TYP) WASHER (TYP) TIN COATED SOLID COPPER BUS BAR S/S FLAT WASHER CHERRY INSULATOR (NP) INSTALLED IF REQUIRED S/S BOLT (TYP) LUG DETAIL SCALE: NOT TO SCALE GROUND BAR STAINLESS STEEL FLAT WASHER STAINLESS STEEL 7 (TYP)BELLVILLE WASHER STAINLESS STEEL NUT (TYP) (TYP) SINGLE CONNECTOR AT GROUND BARS STAINLESS STEEL BOLT STAINLESS STEEL FLAT WASHER DRAGON TOOTH WASHER (TYP) STEEL 2—HOLE CRIMP/ COMPRESSION STAINLESS STEEL CONNECTOR FLAT WASHER (TYP) STAINLESS STEEL STAINLESS STEEL NUT BELLVILLE WASHER (TYP) (TYP) SINGLE CONNECTOR AT STEEL OBJECTS STAINLESS STEEL SELF —DRILLING STAINLESS STEEL METAL SCREW FLAT WASHER (TYP) (TYP) 2—HOLE CRIMP/ COMPRESSION CONNECTOR DRAGON TOOTH METALLIC OBJECT WASHER (TYP) SINGLE CONNECTOR AT METALLIC/STEEL OBJECTS HARDWARE DETAIL FOR EXTERIOR CONNECTIONS SCALE: NOT TO SCALE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q 0 07/01/20 NH CONSTRUCTION MAM 1 07/07/20 AK CONSTRUCTION MAM 2 09/08/20 AK CONSTRUCTION MAM 3 12/02/20 CV CONSTRUCTION MAM p, L by MAGED ABDEL-MESSIH mz=xT1I1I1L! Crown Castle USA Inc. COA #407005050 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: G-2 3 DocuSign Envelope ID: E8E41141-C22B-42DF-A957-564715F8CC8F LTE-3C; Proposed- Alpha/Beta/Gamma Sectors 7001850 D C/Fi be r Demarcation Box x x x A A 6 1 O 1 i u r ' 0 r 0 i AWS/PCSNVCS DocuSign Envelope ID: E8E41141-C22B-42DF-A957-564715F8CC8F Power Plant Model Select D istri huti on type Net u re 51 - 582137000 O U ntac ed U tac ed Trunk Cable Lengthy - one-way (feet) 150 Trunk Cable Size (A - 41 61 9) 9 Jumper Cable Lengthy - one-way (feet) �� Jumper Cable Size (A - Sj 10, or 1) 8 Total Quantity of RRU Feeds 3 o T}/pe Ericsson RRU 447 B14 FRRU Feed Peak DC I nput Power (W) RRLJ Feed Busy Hour Input Power (W) E22. Minimum Source Voltage ( ) 4 Convert er Outp ut Voltage ( ) 58 Minimurn RRU Operating Voltage ( DC) 40 Peak Power Rating of Boost Converter (W) 10C)o Cell& that become highlighted in red indicate that the voltage at the RRU falls below the Minimum R R U operating Voltage. If a cell in a column is highlighted i n red, the RRU will not operate w ith t heat arrangement d ue to the RRU voltage fal ling bel ow its- 9 9 rnini morn operating voltage. A cel I that is re d and reads invali d in di cater that the loss in the cable would exceed the power rating of the RRU and the calculation cannot be performed. Power Extend Converter Layout V without Converter with Converter Total Cable Ioop lengthy (ft.) 330 Cable Resistance (Ohms) 0.2211 RR U Voltage ( DC) at Min Source Voltage and Peak Power 38.24 55.41 RR U Voltage ( DC) at Min Source Voltage and Busy H our 39.64 56.34 RRU Current (A) at Min Source Voltage and Busy Hour 10.66 7.50 Source Power (W) at Min Source Voltage and Busy Hour per RRU 7.6 434.9 Total Source Power (W) at fain Source Voltage and Busy Hour 1342.8 1304.8 Peak Power System Current (A) Required for RRUs 51.0 49.6 Qty of Bullet Converters R eq' d per R R U Feed N/A 1 Qty of Bullet Converters R eq' d per Site N/A 3 # of Total Bullet Positions Required N/A 3 RRU Current (A) at Min Source Voltage and Peak Power 17.00 11.73 Source Power (W) per RRU at Min Source Voltage and Peak RRIJ Power 713.9 680.E Total Source Power (W) at Min Source Voltage and Peak RRIJ Power 1 2141.6 2041.3 won DocuSign Envelope ID: E8E41141-C22B-42DF-A957-564715F8CC8F 0 C B W 8 7 0 7 N 5 3431 NoMs Pcin*E Acworth, Ga 30101 (770) 975-0500 Ofnoe (770) 974.6100 fax 4 ITEM NO 1 2 3 4 5 6 7 8 9 10 11 12 13 DIMENS10%ARE IN INGHES TOLE RA NCES: FRACTIONAL_ t 1/32 ANGULAR: t 2' ONE PLACE DECIMAL: t .66 TWO PLACE DECIMAL: &.03 THREE PLACE DECIMAL: t A10 IN TER PR ET G EOM ETRIC TOLERANCING PER: MATERA L FINISH DO NOTSCALE DRAW IhJ' 4 3 2 F':�.RT I1l_11`%J EER I DESK-F'IF'TI IN T1503KT48A I Universal ring mount 10"-48" K1 5111 KT16HD Extension arm for platform, 1 6" P1500KT6 4.50" OD Pipe, 72" Long T1709KT2SA Pipe mount crossover kit, 2-3/8"-3-1/2" (qty 2) P1200KT8 Pipe, 35' OD x 8' long HDG T1719KTA Pipe frame hardware kit for T-arm P1000KT9,5 1 2-3/8" OD Pipe, 114" Long K1000KT8-534 I Half Clamp, Medium 5-3/4" Center K2220KT8i I Threaded rod 5/811 x 8 HDG H1029KT2GA3 Bolt, 5/811x2" (A325) HH, HDG H3012KT58GSA3 Flat washer, 5/8 SAE (A325). HDC-) H3002KT58G Lock washer, 5/8 HDG H2O02KT58GA3 Nut, hex heavy 5/8" HDG A325 DRAWN CHECKED EN G APPR. MFG APPR. NAME DATE KAR 10/31/16 PROPRIETARYAND CONFIDENTIAL THE INFORMATION CO WA INED IN THE DRAWING ISTHE SOLE PROPERTY 0 F KEfWNOOD TELECOM. APN REPRODUCTION IN PARFORAS A WHOLE VVITHO Uf TH E WRITTEN PERM SSION O F KEMNOOD TELECOM 6 PRO H IBIYE D. 3 NNI K I� io is 04 izlI Ve 72 W KENWOOD TELECOM TITL ustom double t-arm frame, 16" standoff with (9) 114" mast pipe and 1 0"-48" collar SIZE DVVG, NO. HIE V B Z2058KT8-9114-M SCALE: 1: 161 FINISHED WEIGHT: 1698.08 -SHEET 1 CIF 1 2 1 c 101 Docu. .'[CURED Certificate Of Completion Envelope Id: E8E41141C22B42DFA957564715F8CC8F Status: Completed Subject: CV385_842588_TOMLIN_AT&T LTE 3C FCD_REV 3_12.02.2020 Source Envelope: Document Pages: 13 Signatures: 10 Envelope Originator: Certificate Pages: 3 Initials: 0 Jacob Karabasz AutoNav: Enabled 2000 Corporate Drive Envelopeld Stamping: Enabled Canonsburg, PA 15317 Time Zone: (UTC-05:00) Eastern Time (US & Canada) Jacob.Karabasz@crowncastle.com IP Address: 64.213.130.12 Record Tracking Status: Original Holder: Jacob Karabasz Location: DocuSign 12/2/2020 4:28:55 PM Jacob.Karabasz@crowncastle.com Signer Events Signature Timestamp Maged Abdel-Messih by: Sent: 12/2/2020 4:31:36 PM Matthew.Abdel-Messih@crowncastle.com CDocus'9nod 1.al-4 Q(ap d_Akt-SStL Viewed: 12/2/2020 5:57:03 PM Security Level: Email, Account Authentication EE43,dzEA,34b1 Signed: 12/2/2020 5:57:32 PM (None) Signature Adoption: Pre -selected Style Using IP Address: 64.213.130.12 Electronic Record and Signature Disclosure: Accepted: 12/2/2020 5:57:03 PM ID: b270d9dO-34dl-4eO2-bf54-6255704709ae In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 121212020 4:31:36 PM Certified Delivered Security Checked 12/2/2020 5:57:03 PM Signing Complete Security Checked 12/2/2020 5:57:32 PM Completed Security Checked 12/2/2020 5:57:32 PM Payment Events Status Timestamps Electronic Record and Signature Disclosure Electronic Record and Signature Disclosure created on: 9/19/2018 4:13:40 PM Parties agreed to: Maged Abdel-Messih ELECTRONIC RECORD AND SIGNATURE DISCLOSURE In order to provide more efficient and faster service, Crown Castle ("we", "us" or "company") is pleased to announce the use of DocuSign, Inc. ("DocuSign") electronic signing system. The terms for providing such documents for execution and various other documents and records to you electronically through DocuSign are set forth below. Please read the information below carefully and if you can satisfactorily access this information electronically and agree to these terms, please confirm your agreement by clicking the "I agree" button at the bottom of this document. Getting paper copies At any time, you may request from us a paper copy of any document for execution or other document or record provided or made available electronically to you by us. You will be able to download and print documents we send to you through the DocuSign system during and immediately after each signing session and, if you elect to create a DocuSign signer account, you may access them for a limited period of time thereafter. To request paper copies of documents previously provided by us to you electronically, send an e-mail to esignatureOCrownCastle.com, requesting the subject paper copies and stating your e-mail address, name, US Postal address and telephone number. Withdrawing your consent to receive and/or execute documents electronically If you elect to receive documents for execution and various other documents and records from us electronically, you may at any time change your mind and tell us that thereafter you want to receive such documents only in paper format. To withdraw your consent to electronic delivery and execution of documents, use the DocuSign Withdraw Consent' form on the signing page of a DocuSign envelope, instead of signing it. Thereafter, you will no longer be able to use the DocuSign system to electronically receive and execute documents or other records from us. You may also send an e-mail to esignatureACrownCastle.com stating that you are withdrawing your consent to electronic delivery and execution of documents through the DocuSign system and stating your e-mail address, name, US Postal Address, and telephone number. Consequences of withdrawing consent to receive and/or execute documents electronically If you elect to receive documents for execution and various other documents and other records only in paper format, it will slow the speed at which we can complete the subject transactions because of the increased delivery time. Documents for execution, and other documents and records may be sent to you electronically Unless you tell us otherwise in accordance with the procedures described herein, we may provide documents for execution, and other documents and records electronically to you through the DocuSign system during the course of our relationship with you. To reduce the chance of you inadvertently not receiving any document for execution or other document or record, we prefer to provide all documents for execution, and other documents and records by the same method and to the same address that you have given us. If you do not agree with this process, please let us know as described below. How to contact Crown Castle You may contact us to let us know of any changes related to contacting you electronically, to request paper copies of documents for execution and other documents and records from us, and to withdraw your prior consent to receive documents for execution and other documents and records electronically as follows: To contact us by phone call: 724-416-2000 To contact us by email, send messages to: esignatureCdlCrownCastle.com To contact us by paper mail, send correspondence to Crown Castle 2000 Corporate Drive Canonsburg, PA 15317 To advise Crown Castle and DocuSign of your new e-mail address To let us know of a change to the e-mail address where we should send documents for execution and other documents and records to you, you must send an email message to esianatureaCrownCastle.com and state your previous e-mail address and your new e-mail address. In addition, you must notify DocuSign, Inc. to arrange for your new email address to be reflected in your DocuSign account by following the process for changing e-mail in the DocuSign system. Required hardware and software Internet Explorer® 11 (Windows only); Windows Edge Current Version; Mozilla Firefox Current Browsers: Version; SafarlT (Mac OS only) 6.2 or above; Google Chrome Current Version; Note: Pre- release (e.g., beta) versions of operating systems and browsers are not supported. Mobile Signing: jApple iOS 7.0 or above; Android 4.0 or above PDF Reader: Acrobat® Reader or similar software may be required to view and print PDF files Screen Resolution: 1024 x 768 Enabled Security Allow, per session cookies Settings: These minimum reauirements are subiect to chanae. If these requirements chanae. you will be asked to re -accent the disclosure. Pre-release (e.g. beta) versions of operating systems and browsers are not supported. Acknowledging your access and consent to receive documents electronically Please confirm that you were able to access this disclosure electronically (which is similar to the manner in which we will deliver documents for execution and other documents and records) and that you were able to print this disclosure on paper or electronically save it for your future reference and access or that you were able to e-mail this disclosure to an address where you will be able to print it on paper or save it for your future reference and access. Further, if you consent to receiving documents for execution and other documents and records in electronic format on the terms described above, please let us know by clicking the "I agree" button below. By checking the'I agree' box, I confirm that: You can access and read this Electronic Record and Signature Disclosure; and As a recipient, you can read, electronically sign and act upon this message, and you agree not to forward it or any other DocuSign e-mail communications. In the event another party needs to be added to the DocuSign communication, you must make a request to the e-mail originator.