HomeMy WebLinkAboutSDP202100084 Review Comments Final Site Plan and Comps. 2021-12-13AL (*�OV +' County of Albemarle COMMUNITY DEVELOPMENT DEPARTMENT $CI1QS Memorandum To: Ryan Yauger (rvaueer&bohlereng com) From: Kevin McCollum — Senior Planner I Division: Planning Services Date: December 13, 2021 Subject: Final Site Plan SDP202100084 Discount Tire 401 McIntire Road, North Wing Charlottesville, VA 22902-4579 Telephone:434-296-5832 W W W.ALBEMARLE.ORG The Planner for the Planning Services Division of the Albemarle County Department Community Development will recommend approval of the plan referred to above when the following items have been satisfactorily addressed. (The following comments are those that have been identified at this time. Additional comments or conditions may be added or eliminated based on further review.) [Each comment is preceded by the applicable reference to the Albemarle County Code.] Applicable Comments from Initial Site Plan Action Letter (July 28, 2021) If the comment has been addressed, it has been blurred out. Additional comments are added in bold font, like this. 1. [32.7.5.2(d)] Revise the plan to provide additional planting area along the Rt. 29 frontage to accommodate required frontage trees free of utilities and easements. Note that this will likely require the elimination of the 8-space parking row and possibly some of the adjacent travelway. 2. [32.5.2(a)] Please correct the Tax Map and Parcel Number on the cover sheet and any additional TMP reference number on the Plans to say Tax Map and Parcel number or simply TMP instead of "PIN." Revise the TMP reference in the Site Data table on Sheet C-101. 3. [32.5.2(a)(b)] Please include the following general information and information regarding the proposed use on the Cover Sheet. a. Zoning District — Highway Commercial b. Zoning Overlay Districts — Airport Impact Area and Entrance Corridor. Please add "Steep Slopes — Managed" to the Zoning Overlay Districts information in the Site Data table on Sheet C- 101. c. Please include a reference to the Initial Site Plan Number: SDP202100054 d. The proposed use and square footage of the building e. The schedule of parking and amount provided f. Maximum building height permitted and the proposed building height 4. [32.5.2(b), 4.12.61 The parking schedule on Sheet C-301 suggests that there are 15 employees and 6 service bays for a total minimum parking requirement of 27 spaces. Section 4.12.4 of the Zoning Ordinance states that the total nunber of parking spaces provided may not exceed the parking requirements by more than 20 percent. 33 parking spaces is ((33-27)/27 = 0.2222) 22.22 percent more than the parking requirements. Please remove one parking space or revise the Plans accordingly. 5. [32.5.2(i)] Please see VDOT comment #1 (attached). Provide pedestrian accommodations across the entrance. 6. [32.5.2 (k)(I), 32.6.2(g)] Any new easements required for water, sewer, drainage facilities, or any proposed utilities will need to be reviewed, approved, and recorded prior to final site plan approval. Please submit an easement plat application the County for review. The final site plan will need to be updated so that all easements are shown and labeled identifying easement type, whether it's public or private, a width dimension, and the recorded instrument with deed book and page number. Comments stands. 7. [32.7.8 and 4.17.41 Please use a light loss factor of 1.0 to determine footcandles on site. It is unclear what LLF factor was used on the Lighting Plan. 8. [32.7.8 and 4.17.41 Please add a note to which states "Each outdoor luminaire equipped with a lamp that emits 3,000 or more initial lumens shall be a full cutoff luminaire and shall be arranged or shielded to reflect light away from adjoining residential districts and adjacent roads. The spillover of lighting from luminaires onto public roads and property in residential or rural areas zoning districts shall not exceed one-half footcandle." 9. [32.6.2(h)] Please provide a signature panel for signature by each member of the site review committee. 10. [4.12.19(c)] On the final site plan, please provide a plan and profile view detail of the proposed dumpster enclosure. Identify the dimensions, materials, etc. Comment stands. 11. [4.12.19 (b)] Please show that concrete will be used as the surface material at the dumpster enclosure. The concrete pad must extend a minimum of 8' beyond the front of the dumpster. 12. [32.5.2 (q)] Please provide traffic generation figures. See VDOT comments for further information. 13. [32.7.2.1(b)] Please see VDOT comment #4. The proposed entrances to the site do not meet VDOT spacing requirements, and VDOT has stated that an Access Management Exception (AME) needs to be approved in order to allow the proposed entrance location. Please coordinate directly with VDOT to address the AME requirement. 14. [32.7.91 The Site Plan currently shows a 25' landscape buffer along the property frontage. Why is this being provided? Is this an existing easement that applies to the property? Final Site Plan Review Comments 1. [32.6.2] Please include the Final Site Plan Number on the Cover Sheet— SDP202100084. 2. [General Comment] Please add a date of revision to Sheet 2. Please contact Kevin McCollum at the Department of Community Development at kmccollum&albemarle.org or (434) 296-5832 ext. 3141 for further information. Additional Reviewer Comments Albemarle County Engineering Services — David James, diames2@albemarle.org — Requested changes. 1. [C-502] Show HGL in the storm profiles. 2. [C-502] Show VDOT designations, throat length for each DI, grate type for each grate inlet. 3. Easement plat will need to be recorded prior to FSP approval. 4. Provide safety railing for walls over 30" high. 5. Stormwater runoff from parking area is concentrated and must be piped or adequately channeled to STM B-10. 6. Provide half -clogged design for STM B-10 opening following VDOT Drainage Manual. 7. Show vehicle path turning radius by the largest expected vehicle (Auto -turn). Ensure no part of the vehicle crosses over curb or into parking zones. 8. Provide drainage area maps. 9. Provide VDOT MASH guardrail (GR-MGS 1) before wall drop-off (where height is afoot or 10. Note: Separate building permit will be needed for walls over 3-ft high. Albemarle County Building Inspections — Betty Slough, bslou hg &albemarle.org — Requested Changes. 1. Add the following note to the general notes page: Retaining walls greater than 3 feet in height require a separate building permit. Walls exceeding 4 feet in height require a stamped engineered design also. Walls require inspections as outlined in the USBC. 2. Add the following note to the general notes page: Accessible parking spaces, access isles, and accessible route shall be installed in accordance with ICC ANSI Al 17.1-09 and the 2015 Virginia Construction Code. 3. Add the following to the general notes page: All roof drains shall discharge in a manner not to cause a public nuisance and not over sidewalks. 4. Add the following note to the general notes page: Buildings or structures built before January 1, 1985 must have an asbestos survey performed in order to apply for a demolition permit. Asbestos removal permits are required if positive for such from Albemarle County and VDOLI. Contact VDOLI for their additional requirements and permits for demolition projects at 540-562-3580 x131. 5. Add the following note to the general notes page: All water, sewer and fire lines require NEW inspection and testing procedures. The ACSA performs any testing and inspections of the public sewer and water main(s).The Albemarle County Building Inspections Department(ACBID) does a visual inspection and witnesses the testing of the building drain, water service pipe and the sprinkler lead-in connection. The developer/contractor is responsible to retain a Special Inspector as outlined in the updated Albemarle County Policy for Site Utilities to perform the visual inspection and testing of all utilities not covered by the ACSA or ACBID. This includes building sewers, water and fire line branches between the main and the meter(s)/building(s).The Special Inspector's report must be submitted and approved by the Albemarle County Engineering Department prior to a Certificate of Occupancy being issued. Albemarle County Fire -Rescue — Howard Lagomarsino, hlaeomarsino@albemarle.org — Requested changes. 1. There is an FDC near the NW comer of the building suggesting presence of sprinkler system. A fire hydrant is required within 100 It of the FDC and arranged so that when in use with the FDC, the travel way is not obstructed 2. I see the types of fire lane signs and appreciate the notation, but do not see the locations they are installed at on the site plan, including sheet C303 3. Please clarify the locations of the hydrant mentioned as within 250 ft of building 4. Indicate with a note on the plan, the needed fire flow for the building in accordance with ISO Virginia Department of Transportation (VDOT) — Adam Moore, Adam.Moorekvdot.vir iginia.gov — Requested changes, see comments attached. Albemarle County Service Authority (ACSA) — Richard Nelson, melson&serviceauthority.org — Review pending. Any applicable comments will be forwarded to the Applicant upon receipt. Albemarle County E911—Elise Kiewra, ekiewra@albemarle.org—No Objection. Albemarle County Architectural Review Board — Khristopher Taggart, ktaeeart@albemarle.org — See comments from 12/6/2021 ARB meeting, attached. Virginia Department of Health — Alan Mazurowski, alan.mazurowski@vdh.virginia.gov — No objection. Rivanna Water and Sewer Authority — Victoria Fort, vfort&rivanna.org — Review pending. Any applicable comments will be forwarded to the Applicant upon receipt. COMMONWEALTH of VIRGINIA DEPARTMENT OF TRANSPORTATION Stephen C. Brich, P.E. 1401 East Broad Street (804) 7862701 Commissioner Richmond, Virginia 23219 Fax: (804) 7862940 November 15, 2021 County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Attn: Kevin McCollum Re: Discount Tire — Final Site Plan SDP-2021-00084 Review # 1 Dear Mr. McCollum: The Department of Transportation, Charlottesville Residency Transportation and Land Use Section, has reviewed the above referenced plan as prepared by Bohler Engineering, dated 29 October 2021, and offers the following comments: 1. Label the ADA pedestrian ramps across the vehicle entrance as CG-12 and show the detectable warning surface. 2. Plans appear to show brick -pattern for entire entrance into the road. Show the brick - pattern crosswalk with asphalt pavement going into the road, for one lane -width, for the length of 2' beyond either side of the entrance. 3. The sidewalk appears to narrow from the existing sidewalk to the minimum 5' width across the front of the subject -property. Keep the existing width of the sidewalk for its entire length. 4. Where does Structure B-10 discharge to? Please provide a digital copy in PDF format of the revised plan along with a comment response letter. If further information is desired, please contact Doug McAvoy Jr. at (540) 718-6113. A VDOT Land Use Permit will be required prior to any work within the right-of-way. The owner/developer must contact the Charlottesville Residency Transportation and Land Use Section at (434) 422-9399 for information pertaining to this process. Sincerely, Doug McAvoy Jr., P.E. Area Land Use Engineer Charlottesville Residency VirginiaDOT.org WE KEEP VIRGINIA MOVING County of Albemarle i Community Development Department - Planning December 7- 2021 Ryan Yauger, P.E. Bohler Engineering 9100 Arboretum Parkway, Suite 360 Richmond, VA 23236 RE: ARB2021-131: Discount Tire Final (TMP: 06100-00-00-120J0) Dear Mr. Yauger, Khris Taggart, Planner ktaggart@albemarle.org Telephone: (434) 296-5832 ext. 3278 The Albemarle County Architectural Review Board reviewed the above noted item at its meeting on Monday, December 6, 2021. The Board unanimously approved the request, pending staff administrative approval of the following conditions: 1. Provide a sample of the corrugated metal siding for review. 2. Revise the architectural drawing to indicate the proposed block size for the masonry. 3. Align the storefront heights on the EC elevation with those on the south side and add a canopy to the middle bay of the EC elevation. 4. Revise the plant trellises to extend down the elevation to the to match the form of the bay doors along the south elevation. Remove the trellis closest to the EC street. 5. Revise the architectural drawings to include the standard window glass note: Visible light transmittance (VLT) shall not drop below 40916. Visible light reflectance (VLR) shall not exceed 30%. 6. Consider revising the site plan to relocate the electrical switch cabinet to eliminate visibility from the EC. Alternatively add a wing wall and paint the cabinet to match the building. Add a note to the site plan to identify the cabinet. 7. Revise the elevation drawings to show the roof -mounted mechanical equipment to confirm that it will be screened from view of the EC. 8. Add the standard mechanical equipment note to the architectural drawing: "Visibility of all mechanical equipment from the Entrance Corridor shall be eliminated." 9. Revise the lighting plan to indicate the fixture color for the pole -mounted lighting. 10. Consider revising the plan to provide additional planting area along the Rt. 29 frontage to accommodate required frontage trees free of utilities. Note that this will likely require the elimination of some parking spaces in the 8- space parking row adjacent to the Rt. 29 frontage. Alternatively, locate larger trees further into the planting area towards the building and one in the parking area, eliminating one parking space. 11. Revise the site plan set to consistently show the existing water line as being removed. 12. Revise the deciduous landscaping along the northern perimeter of the site to evergreens. 13. Revise the site plan set to show the planting beds and plants proposed for the trellises. 14. Revise the plan to indicate the color of the retaining wall sample that has been submitted. 15. Please note separate sign applications are required for all proposed signs. The following comments provided with the initial review still apply: a. Revise the wall signs to use either face illumination or halo illumination. b. Revise the sign proposed on the south elevation so that it has a more coordinated appearance. This can be done by reducing the size of the sign and/or changing the layout to a single line of text. c. The background of any cabinet signs proposed will be required to have an opaque background if internally illuminated. d. Include the size of the existing freestanding sign on the sign drawings. If the sign is taller than 12' and larger than 32 square feet, the proposal must include a 25% reduction in height and area until the height reaches 12' and area reaches 32 sf. WWW.ALBEMARLLORG 401 McIntire Road, North Wing, I Charlottesville, VA 22902-4579 Please provide: 1. One full set of revised drawings addressing each of these conditions. Include updated ARB revision dates on each drawing. 2. A memo including detailed responses indicating how each condition has been satisfied. If changes other than those requested have been made, identify those changes in the memo also. Highlighting the changes in the drawing with "clouding" or by other means will facilitate review and approval. 3. The attached "Revised Application Submittal' form. This form must be returned with your revisions to ensure proper tracking and distribution. When staffs review of this information indicates that all conditions of approval have been met, a Certificate of Appropriateness may be issued. If you have any questions, please do not hesitate to contact me. Sincerely, Khris Taggart, Planner cc: Mimosa LLC Attn: Frank Brickhead c/o Duffy Brickhead P.O. Box 7652 Charlottesville, VA 22906 File WWW.ALBEMARLE.ORG 401 McIntire Road, North Wing, I Charlottesville, VA 22902-4579 COUNTY OF ALBEMARLE Department of Community Development REVISED APPLICATION SUBMITTAL This form must be returned with your revisions to ensure proper tracking and distribution. County staff has indicated below what they think will be required as a resubmission of revisions. If you need to submit additional information please explain on this form for the benefit of the intake staff. All plans must be collated and folded to fit into legal size files, in order to be accepted for submittal. TO: PROJECT NAME: DATE: Submittal Type Requiring Revisions I> indicates submittal Code County Project Number # Copies Erosion & Sediment Control Plan E&S Mitigation Plan MP Waiver Request WR Stormwater Management Plan SWMP Road Plan RP Private Road Request, with private/public comparison PRR Private Road Request — Development Area PRR-DA Preliminary Site Plan PSP Final Site Plan or amendment FSP Final Plat FP Preliminary Plat PP Easement Plat EP Boundary Adjustment Plat BAP Rezoning Plan REZ Special Use Permit Concept Plan SP-CP Reduced Concept Plan R-CP Proffers P Bond Estimate Request BER Draft Groundwater Management Plan D-GWMP Final Groundwater Management Plan F-GWMP Aquifer Testing Work Plan ATWP Groundwater Assessment Report GWAR Architectural Review Board ARB ARB-2021-131 1 Other: Please explain For staff use only) Submittal Code # Copies Distribute To: Submittal Code # Copies Distribute To: ARB 1 Khris Taggart WWW.ALBEMARLLORG 401 McIntire Road, North Wing, I Charlottesville, VA 22902-4579