HomeMy WebLinkAboutSUB201800177 Correspondence 2019-11-25Patricia "Paty" Saternye From: Ernest Beasley<ebeasley@hydrogeoenvironmental.com> Sent: Monday, November 25, 2019 10:45 AM To: John Anderson Cc: Emily Cox; Christopher Perez; Patricia Saternye Subject: Re: SUB201900176 - Property of Bella Signature Homes LLC, Final Plat - GWA study [ Engineering review comments ] CAUTION: This message originated outside the County of Albemarle email system. DO NOT CLICK on links or open attachments unless you are sure the content is safe. Thanks - I will be in a meeting from 11:00 until about noon so please wait until early afternoon to call me. Thanks again, Bubba Beasley, CPG Geologist c: (404) 219-6676 www.HvdroGeoEnvironmental.com ❑" On Mon, Nov 25, 2019 at 10:41 AM John Anderson <]anderson2@albemarle.org> wrote: Ernest, Thanks for your call a few moments ago. I said I would call, and will, but want to reprint review item 5, and ask for well test regime (response) to address this item. I believe developer and Albemarle alike will benefit from actual on -site /site -specific groundwater (well test) data. Albemarle needs sense of assurance rip Or t0 final plat approval to shield county and future property owner needs. Item 5 5. Report assessment of well drilling and testing, spatial variability of well yields, the relative lack of yield data within 1,000' radius of the parcel, requires test well results: a. Engineering recommends HydroGeo Environmental coordinate with Applicant, select a test drill location coincident with the proposed well site location evaluated (for reasons HydroGeo should outline for Engineering) to have low if not lowest potential well yield, and provide well test results in accord with VDH well test protocol. Should this test well yield at least 3 gpm, Engineering will approve the Tier III Groundwater Assessment. The only VDH available data within 1,000 of the parcel to be subdivided yields 2eom, which is insufficient for VDH permitting purposes. Additional site -specific data is required to advance the final subdivision plat. b. Alternative to item 5.a.: If proposed location rated least likely to yield 3 gpm does not yield 3 gpm, Applicant should test a second of the five well sites for this 5-lot subdivision (ref. report /sketch — Attachment A), and may choose a proposed well site evaluated most favorable, perform well test, and average the two well test values. If this approach does not yield an average > 3 gpm, then Applicant may persuade Albemarle that each of the proposed subdivided lots has reasonable chance of encountering subsurface flow sufficient to support required 3 gpm, but this would seem doubtful. Water budget calculations have little to do with peril faced by property owners unable to establish a well supply that yields 3 gpm. Yields are influenced by chance, and additional site - specific information is required prior to Tier III GW Assessment Report approval. I will call in 20 -30 minutes, and appreciate your patience, and expertise. Thank you best, J. Anderson 434.296-5832 -x3069 From: John Anderson Sent: Monday, November 25, 2019 10:00 AM To: Ernest Beasley<ebeaslev@hvdrogeoenvironmental.com> Cc: Emily Cox <ecox2@albemarle.org>; Christopher Perez <cperez@albemarle.org>; Patricia Saternye <psaternye@ al bema rle.org> Subject: SUB201900176 - Property of Bella Signature Homes LLC, Final Plat - GWA study [ Engineering review comments I Ernest, Thanks for speaking with me, moments ago. I regret I did not ensure review comment reached you, sooner —it's my fault. Thanks for your patience. Please call if any questions. best, J. Anderson 434.296-5832 -x3069 John Anderson, PE, Civil Engineer II • (434) 296-5832 -X3o69 Community Development Dept. I Engineering Division County of Albemarle 1401 McIntire Road Charlottesville, Virginia 22902-4596 Patricia "Paty" Saternye From: John Anderson Sent: Monday, November 25, 2019 10:41 AM To: Ernest Beasley Cc: Emily Cox; Christopher Perez•, Patricia Saternye Subject: RE: SUB201900176 - Property of Bella Signature Homes LLC, Final Plat - GWA study [ Engineering review comments ] Ernest, Thanks for your call a few moments ago. I said I would call, and will, but want to reprint review item 5, and ask for well test regime (response) to address this item. I believe developer and Albemarle alike will benefit from actual on -site /site -specific groundwater (well test) data. Albemarle needs sense of assurance rip or to final plat approval to shield county and future property owner needs. Item 5 5. Report assessment of well drilling and testing, spatial variability of well yields, the relative lack of yield data within 1,000' radius of the parcel, requires test well results: a. Engineering recommends HydroGeo Environmental coordinate with Applicant, select a test drill location coincident with the proposed well site location evaluated (for reasons HydroGeo should outline for Engineering) to have low if not lowest potential well yield, and provide well test results in accord with VDH well test protocol. Should this test well yield at least 3 gpm, Engineering will approve the Tier III Groundwater Assessment. The only VDH available data within 1,000 of the parcel to be subdivided yields 2eom, which is insufficient for VDH permitting purposes. Additional site -specific data is required to advance the final subdivision plat. b. Alternative to item 5.a.: If proposed location rated least likely to yield 3 gpm does not yield 3 gpm, Applicant should test a second of the five well sites for this 5-lot subdivision (ref. report /sketch — Attachment A), and may choose a proposed well site evaluated most favorable, perform well test, and average the two well test values. If this approach does not yield an average > 3 gpm, then Applicant may persuade Albemarle that each of the proposed subdivided lots has reasonable chance of encountering subsurface flow sufficient to support required 3 gpm, but this would seem doubtful. Water budget calculations have little to do with peril faced by property owners unable to establish a well supply that yields 3 gpm. Yields are influenced by chance, and additional site - specific information is required prior to Tier III GW Assessment Report approval. I will call in 20 -30 minutes, and appreciate your patience, and expertise. Thank you best, J. Anderson 434.296-5832 -x3069 From: John Anderson Sent: Monday, November 25, 2019 10:00 AM To: Ernest Beasley <ebeasley@hydrogeoenvironmental.com> Cc: Emily Cox <ecox2@albemarle.org>; Christopher Perez <cperez@albemarle.org>; Patricia Saternye <psaternye@a I bemarle.org> Subject: SUB201900176 - Property of Bella Signature Homes LLC, Final Plat - GWA study [ Engineering review comments Emest, Thanks for speaking with me, moments ago. I regret I did not ensure review comment reached you, sooner —it's my fault. Thanks for your patience. Please call if any questions. best, J. Anderson 434.296-5832 -x3069 John Anderson, PE, Civil Engineer II • (434) 296-5832 -R3o69 Community Development Dept. I Engineering Division County of Albemarle 1401 McIntire Road Charlottesville, Virginia 22902-4596 Patricia "Paty" Saternye From: John Anderson Sent: Monday, November 25, 2019 10:00 AM To: Ernest Beasley Cc: Emily Cox; Christopher Perez; Patricia Saternye Subject: SUB201900176 - Property of Bella Signature Homes LLC, Final Plat - GWA study [ Engineering review comments ] Attachments: SUB201800177 Bella Signature GWA 030719.pdf Ernest, Thanks for speaking with me, moments ago. I regret I did not ensure review comment reached you, sooner —it's my fault. Thanks for your patience. Please call if any questions. best, J. Anderson 434.296-5832 -x3069 John Anderson, PE, Civil Engineer II • (434) 296-5832 -x3o69 Community Development Dept. I Engineering Division County of Albemarle 1401 McIntire Road Charlottesville, Virginia 22902-4596 Patricia "Paty" Saternye From: Patricia Saternye Sent: Monday, November 25, 2019 9:08 AM To: John Anderson Subject: FW: Tier 3 Groundwater Assessment for Bella Signature Homes (SUB2018-177 - Preliminary Plat) Attachments: SUB2018-177 Approval with Conditions 12-21-2018c.pdf John, I'm still digging, but it appears they provided you with a 2nd submission of the Tier 3 Groundwater Assessment after the comments for the Preliminary Site Plan. Please see the email below. That makes me think they got at least the 1'set of comments on the Groundwater Study. In looking at the string of emails below, it appears to me that after the 1' draft of the Groundwater Study was reviewed by you (and the preliminary plat was approved) they chose to resubmit the Groundwater Study a 2"d time even though they had not yet submitted a Final Plat. Could that be what is causing some of the confusion? Question: Could you clarify for me if you wanted me to check if I had sent them the comments on the V submission of the Groundwater Study (with the preliminary plat) or the 2nd submission of the Groundwater Study (between the preliminary plat approval and final plat submission)? That might help me know what time frame to look in. Thanks, Paty Saternye Senior Planner Community Development o , U� Albemarle County 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternye@albemarle.org www.albemarle.org From: Patricia Saternye <psaternye@albemarle.org> Sent: Thursday, January 31, 2019 12:58 PM To: John Anderson <janderson2@albemarle.org> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes (SUB2018-177 - Preliminary Plat) My comment #1 (attached) states that they were supposed to submit the draft study prior to the preliminary plat approval, that they did, and to see your comments the draft report that was submitted. So, if they did it correctly, what is attached should be the revised and final version of the study that is supposed to be submitted with the final plat. Thanks, Paty Saternye Senior Planner Community Development o , U� Albemarle County 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternve@albemarle.ore www.albemarle.ora From: John Anderson Sent: Thursday, January 31, 2019 12:53 PM To: Patricia Saternye <psaternve@albemarle.org> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes thanks From: Patricia Saternye Sent: Thursday, January 31, 2019 12:52 PM To: John Anderson <janderson2@albemarle.ore> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes John, I would have to look back at the comments, but if the preliminary is approved it might not be necessary to review the Tier III until the final plat is submitted. I'll try to look at that later today or tomorrow morning. Thanks, Paty Saternye Senior Planner Community Development Albemarle County 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternve@albemarle.ore www.albemarle.org From: John Anderson Sent: Thursday, January 31, 2019 12:44 PM To: Patricia Saternye <psaternve@albemarle.ore> Cc: Ernest Beasley<ebeaslev@hvdroaeoenvironmental.com> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes Paty, No, a single fee is sufficient. I will review the digital Tier III report as soon as possible, and have added a task under preliminary subdivision plat —thanks, Paty. Mr. Beasley, The report is logged /in my review queue. I will review as soon as possible and withdraw request for an application related to GW assessment —thanks for sending. -best, J. Anderson 434.296-5832 -x3069 From: Patricia Saternye Sent: Thursday, January 31, 2019 12:36 PM To: John Anderson <janderson2@albemarle.ore> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes John, It appears on County View that the Fee for the Tier III Groundwater Study, for the approved SUB2018-177 Properties of Bella Signature Homes PRELIMINARY Plat, has been previously paid. Unless there is a new/different fee at the Final Plat stage, on top of the one at the Preliminary, he may not owe it. I'm not sure if there is a second fee, but I don't think there is... maybe we should ask Matt. I have not received the final plat submission yet... Thanks, Paty Saternye Senior Planner Community Development Albemarle County 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternve@albemarle.ore www.albemarle.org From: John Anderson Sent: Thursday, January 31, 2019 12:29 PM To: Ernest Beasley <ebeaslev@hydrogeoenvironmental.com> Cc: Patricia Saternye <psaternye@albemarle.org> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes (Paty, please advise —thanks ) Thanks for your email, Mr. Beasley. Please submit a subdivision application (with fee) with print copy of Tier III report to get into review queues. Since this is a subdivision application, I rely on Paty for guidance. It appears a 548 fee is required with Application (image, below: pg. 3 /Application) Groundwater Review /•ices ❑ Tier 2 Ground"aier ReN iew = S355 (Required for all plats proposing lots less than 21 acre! J Tier 3 GroundN%alcr Re%icw = S548 (Required for all plats proposing lots where at least 3 1. acres or less) U Tier 4 Groundwater Review = S1,183 Link to Application: http://www.albemarle.or Lupload/itnagestfonns_center/departments/Community Development/forms/applications/Subdiv ision Plat & Cheeklist.odf I look forward to receiving a print copy of the Tier 3 report, once submitted with Application. Thanks again -best, J. Anderson 434.296-5832 -x3069 From: Ernest Beasley <ebeaslev@hydrogeoenvironmental.com> Sent: Thursday, January 31, 2019 12:08 PM To: John Anderson <ianderson2@albemarle.org> Cc: Luke Kitelinger <Kitelingerl@yahoo.com>; Bryan Chambers<chamberslandsurveying@yahoo.com>; Kathryn Bryant <Kathryn@hydrogeoenvironmental.com>;1P Ligush<ipligush@hydrogeoenvironmental.com> Subject: Tier 3 Groundwater Assessment for Bella Signature Homes Mr. Anderson, Please see the attached Tier 3 Groundwater Assessment HydroGeo has completed on behalf of Bella Signature Homes, LLC for Albemarle Parcel #45-59M. Don't hesitate to reach out to me with any questions or comments. Many thanks, Bubba Beasley, MS, CPG Geologist c: (404) 219-6676 www.HvdroGeoEnvironmental.com 10 Patricia "Paty" Saternye From: John Anderson Sent: Friday, November 22, 2019 3:36 PM To: Patricia Saternye Subject: FW: Planning Application Review for SUB201800177 PROPERTY OF BELLA SIGNATURE HOMES, LLC - PRELIMINARY. [ Tier III Groundwater Assessment -Engineering Review ] Attachments: SUB201800177 Bella Signature GWA 030719.pdf Hi, Paty, I received voicemail re. GWA, and wonder if Attached was shared with Applicant —this all goes back a ways. Please let me know —thanks, Paty! Enjoy the weekend. From: John Anderson Sent: Thursday, March 7, 2019 11:05 AM To: Patricia Saternye <psaternye@albemarle.org> Subject: Planning Application Review for SUB201800177 PROPERTY OF BELLA SIGNATURE HOMES, LLC - PRELIMINARY. [ Tier III Groundwater Assessment -Engineering Review ] The Review for the following application has been completed: Application Number = SUB201800177 Reviewer = John Anderson Review Status = Requested Changes Completed Date = 03/07/2019 This email was sent from County View Production. Paty, Attached Engineering review comments of the Tier III Groundwater Assessment report is for now located with preliminary plat (CV), but Engineering will upload to final plat (CV file #), once FPT received, and file # established for FPT. Please share with applicant at your convenience. Thanks best, JA x3069 Text of review comments: Engineering review of Tier III GW Assessment report is complete. SUB2018-00177 11 1. Tier III Groundwater Assessment: Albemarle County Parcel #45-59M for Bella Signature Homes, LLC, dated 1/29/19, is comprehensive, but is not approved. 2. Findings detail efforts to obtain well data from VDH, but VDH, as of report date, has been non -responsive to FOIA request for detailed well and septic records for parcels located up to 1000-feet beyond the property lines (ref. ACDSM, Sec. 2.D.l.a.l.d.). Table 1 (p. 5, report), Summary of Available Well Records, indicates the average yield of seventeen (17) well records for wells located within a 0.5 mile radius of the property is 12.9 gpm. Sec. 7,0, Conclusions (p. 6, report) states, "VDH regulations require a minimum yield of 3 gom for private residential water supply wells, while Sec. 6.0, Assessment of Well Drilling and Testing, states, "Based on this study, the Site lies in an area capable ofproducing groundwater yield sufficient to meet the demands of the proposed Site development; however, the actual yields of future onsite supply wells cannot be known until the wells are drilled and properly tested." [Emphasis added.] 3. The only well listed in Table 1 located within one thousand feet of the parcel yields 2 gum. The Tier III report states, "Standard practice for development of water supply wells involves drilling into water bearing zones in the fractured bedrock and sealing off the overburden with a solid well casing. Thus, the ultimate performance of individual water wells in the Blue Ridge Province typically depends on the borehole encountering sufficiently interconnected bedrock fractures. A dry hole results if a well is drilled into bedrock with insufficient fracturing. Fracture occurrence and density depend on a number of factors including specific location, rock type, and site -specific geologic conditions. Because groundwater occurs in discrete fractured zones, it is not unusual to find variability in yields for wells in close proximity to each other. Because the regolith provides groundwater storage, a thicker mantle of overburden usually suggests more favorable conditions for sustainable long-term groundwater withdrawals." (p. 3, emphasis added). 4. Attachment D Water Budget Calculations for Tier III GW Assessment (Albemarle Co. Parcel #45-59M), rounding difference: If use .0015 feet vs .00147 as average regional daily groundwater recharge value, this increases the post - development groundwater surplus report value by a negligible amount (=2%). Attachment D projects 13244 god sumlus (post -development). For comparison, a household of five is estimated to consume 500 gpd, and the proposed five additional households in the watershed are included (subtracted) when calculating the 13,244 gpd surplus (if use .00147, surplus value decreases slightly to=12,851 gpd). Attachment D calculations may assume 1,000' x 20' principal access /road, may apportion 9,068 ft2 new impervious area per lot. Even allowing 100' x 12' stone or paved driveway allows 7,868 ft2 of impervious roof, walk, etc., per lot, which is conservative. Attachment D appears reasonable and accurate, and is accepted. 5. Report assessment of well drilling and testing, spatial variability of well yields, the relative lack of yield data within 1,000' radius of the parcel, requires test well results: a. Engineering recommends HydroGeo Environmental coordinate with Applicant, select a test drill location coincident with the proposed well site location evaluated (for reasons HydroGeo should outline for Engineering) to have low if not lowest potential well yield, and provide well test results in accord with VDH well test protocol. Should this test well yield at least 3 gpm, Engineering will approve the Tier III Groundwater Assessment. The only VDH available data within 1,000 of the parcel to be subdivided yields 2gpm, which is insufficient for VDH permitting purposes. Additional site -specific data is required to advance the final subdivision plat. b. Alternative to item 5.a.: If proposed location rated least likely to yield 3 gpm does not yield 3 gpm, Applicant should test a second of the five well sites for this 5-lot subdivision (ref. report /sketch —Attachment A), and may choose a proposed well site evaluated most favorable, perform well test, and average the two well test values. If this approach does not yield an average >_ 3 gpm, then Applicant may persuade Albemarle that each of the proposed subdivided lots has reasonable chance of encountering subsurface flow sufficient to support required 3 gpm, but this would seem doubtful. Water budget calculations have little to do with peril faced by property owners unable to establish a well supply that yields 3 gpm. Yields are influenced by chance, and additional site -specific information is required prior to Tier III GW Assessment Report approval. 6. Minor: Reduced -size plat /sketch scales are inaccurate. Include note that defines accurate scale, or revise plat sketches included with report using hand -notation to indicate an accurate scale so that a reader may refer to scale, and acquire accurate length or distance information from plats included with the report. Please call Engineering at 434.296-5832 -0069 if any questions. Thank you 12 Patricia "Paty" Saternye From: Patricia Saternye Sent: Thursday, November 7, 2019 3:44 PM To: Christopher Perez Subject: SUB2018-177 word docs for prelim approval with conditions Attachments: CDP1_sub_PCS_Bella Homes - Prelim UPDATE 12-20-2018a.doc; CDP1_sub _PCS_Bella Homes - Prelim UPDATE 12-20-2018a.doc SUB2018-177 word docs for prelim approval with conditions Paty Saternye Senior Planner Community Development =4 V .a�/Rcl�*I. Albemarle County 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternve@albemarle.org www.albemarle.org 13 Patricia "Paty" Saternye From: Patricia Saternye Sent: Monday, July 15, 2019 2:58 PM To: Emily Cox Subject: RE: Planning Application Review for SUB201900031 EARLYSVILLE SUBDIVISION - ROAD PLANS. Attachments: CDP2_sub_PCS_Earlysvilie Road Subdiv Road Plan 7-15-2019b.pdf; CDP2 _sub_PCS_Earlysville Road Subdiv Road Plan 7-15-2019b.doc Emily, Attached please see the planning comments for SUB201900031 EARLYSVILLE SUBDIVISION - ROAD PLANS. Please let me know if you have any questions prior to sending them to the applicant. I have not yet uploaded them to County View. Thanks, Paty Saternye Senior Planner Community Development a , A Albemarle County 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternve@albemarle.ore www.albemarle.ora From: Patricia Saternye Sent: Tuesday, April 23, 2019 11:44 AM To: Emily Cox <ecox2@albemarle.org>; Clint Shifflett <Clint.Shifflett@timmons.com> Cc: kitelingerl@yahoo.com Subject: RE: Planning Application Review for SUB201900031 EARLYSVILLE SUBDIVISION - ROAD PLANS. Emily & Clint, Attached please find the planning comments for SUB201900031 EARLYSVILLE SUBDIVISION - ROAD PLANS. I apologize for these not being available when the other review comments went out late last week. Thanks, Paty Saternye Senior Planner Community Development =4 a °� " `��R41N��R Albemarle County 14 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternve@albemarle.ore www.albemarle.org From: Emily Cox Sent: Thursday, April 18, 2019 10:30 AM To: Clint Shifflett <Clint.Shifflett@timmons.com>; kitelingerl@vahoo.com Cc: Patricia Saternye <psaternve@albemarle.org> Subject: Planning Application Review for SUB201900031 EARLYSVILLE SUBDIVISION - ROAD PLANS. Clint — See attached. Please note that this is still under review by planning as noted in the comment letter. Let us know if you have any questions. Thanks! The Review for the following application has been completed: Application Number = SUB201900031 Reviewer= Emily Cox Review Status = Requested Changes Completed Date = 04/18/2019 This email was sent from County View Production. 15 Patricia "Paty" Saternye From: Patricia Saternye Sent: Thursday, May 9, 2019 2:26 PM To: Catherine Gayner Cc: Clint Shifflett Subject: RE: Earlysville Road Subdivision SBU2019-31 comments Catherine, Please clarify if your questions are forthe comments in the Road Plan (SUB2019-31) or the Preliminary Plat (SUB2018- 177). Because of the context of your question I am assuming you are referring to the Road Plan comment numbers. Please correct me if I'm wrong. The preliminary plat is not normally submitted more than once. If you were supposed to resubmit the preliminary plat you would have had to do so prior to its approval with conditions. The preliminary was submitted more than once in this case because of the missing road stormwater management. The first round of comments were on 11/13/18. The 2"' round of comments, which was also the "approval with conditions" letter was sent on 12/20/18. In that approval with conditions letter where were comments/conditions that must be addressed with the submission of the "final plat". On that final plat submission you must show the easements and you create them. If you choose, the storm (both road drainage & facilities) easement can be submitted separately. However, 1) the separate easement plat in that case must be approved before the final plat can be approved. 2) Most people include the easements in the final subdivision plat to save a step, and therefore a bit of time and money. In reference to the road plan showing the metes and bounds it is my understanding that is part of the required information. However, if you need me to ask others to confirm that please let me know. It is my understanding that road plans show everything that is required to create the road. Once that is approved by engineering, then the matching information also needs to be included in the final plat where the ROW will actually be created. Thanks, Paty Saternye Senior Planner Community Development V� ��Rbl Albemarle County 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternye@albemarle.ore www.albemarle.org From: Catherine Gayner <Catherine.Gayner@timmons.com> Sent: Thursday, May 09, 2019 1:47 PM 16 To: Patricia Saternye <psaternye@albemarle.org> Cc: Clint Shifflett <Clint.Shifflett@timmons.com> Subject: Earlysville Road Subdivision SBU2019-31 comments Hi Paty, I have a couple questions pertaining to your comments for the Earlysville Subdivision Road plan. Pertaining to comment #4, could you please confirm that these easements need to be recorded in a final subdivision/easement plat and that the approved preliminary plat does not need to be revised? Pertaining to comment #7, the boundary, ROW, and easement metes and bounds will be provided in the final plat to be recorded. Is it necessary for us to put these in the road plan? We have been referencing the approved Woodlawn Subdivision Road Plan (SUB201600066), which did not have boundary, ROW, and easement metes and bounds. Thank you, Catherine Gayner Project Engineer TIMMONS GROUP I www.timmons.com 608 Preston Avenue Suite 200 1 Charlottesville, VA 22903 Office: 434.295.5624 Mobile: 757.615.1408 catheri ne. a ayner(cDti mmo ns. com Your Vision Achieved Through Ours To send me files greater than 20MB click here. 17 Patricia "Paty" Saternye From: Catherine Gayner <Catherine.Gayner@timmons.com> Sent: Thursday, May 9, 2019 1:47 PM To: Patricia Saternye Cc: Clint Shifflett Subject: Earlysville Road Subdivision SBU2019-31 comments Hi Paty I have a couple questions pertaining to your comments for the Earlysville Subdivision Road plan. Pertaining to comment #4, could you please confirm that these easements need to be recorded in a final subdivision/easement plat and that the approved preliminary plat does not need to be revised? Pertaining to comment #7, the boundary, ROW, and easement metes and bounds will be provided in the final plat to be recorded. Is it necessary for us to put these in the road plan? We have been referencing the approved Woodlawn Subdivision Road Plan (SUB201600066), which did not have boundary, ROW, and easement metes and bounds. Thank you, Catherine Gayner Project Engineer TIMMONS GROUP I www.timmons.com 608 Preston Avenue I Suite 200 1 Charlottesville, VA 22903 Office: 434.295.5624 1 Mobile: 757.615.1408 catherine.oaynerna.timmons.com Your Vision Achieved Through Ours To send me files greater than 20MB click here. 18 Patricia "Paty" Saternye From: Cisco Unity Connection Messaging System <unityconnection@cobm- cucxnpub.albemarle.org> Sent: Wednesday, May 1, 2019 11:36 AM To: psaternye@cobm-cucxnpub.albemarle.org Subject: Message from VIRGINIA CALL (94349603085) Attachments: VoiceMessage.wav Categories: ViewMail 19 Patricia "Paty" Saternye From: Patricia Saternye Sent: Monday, April 29, 2019 9:41 AM To: Jeffrey Baker Subject: FW: Planning Application Review for SUB201900031 EARLYSVILLE SUBDIVISION - ROAD PLANS. Jeff, The subdivision plat that has already been reviewed for the property is SUB201800177 PROPERTY OF BELLA SIGNATURE HOMES, LLC— PRELIMINARY. That is only a "preliminary". The final plat has not been submitted or approved. The road plan reference it below. The key is that he does not have the subdivision approved yet. It is my understanding that he wants to build one by -right residence on the current lot as is. However, he want to ensure he does not do anything that will jeopardize his future (in process) subdivision of the other 4 lots. So he would have to come up with a residence location that can meeting both existing and future requirements. I have mentioned some possible red flags below to him. I cannot guarantee that we will successfully avoid causing future problems with the future division. Thanks, Paty Saternye Senior Planner Community Development Albemarle County 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternve@albemarle.ore www.albemarle.org From: Patricia Saternye Sent: Wednesday, April 24, 2019 2:56 PM To: kitelingerl@yahoo.com Cc: Jeffrey Baker <jbaker@albemarle.org> Subject: RE: Planning Application Review for SUB201900031 EARLYSVILLE SUBDIVISION - ROAD PLANS. Mr. Kitelinger, I've double checked and Jeff Baker (ibaker@albemarle.orx) is the correct person to help you with your current question of building one residence on your current parcel. So, I have copied him on this email. Any questions you have about getting a building permit and building one residence on the existing parcel please forward to him. 20 Four things I just wanted to broach in reference to our discussion a few minutes ago: 1. As we talked about, only the preliminary subdivision plat has been approved. What is currently under review is the Road Plan. The final subdivision plat has yet to have been submitted for the first review. So, please know that process is still in the future. 2. Since the final subdivision plat has not been submitted, reviewed and approved any building you do at this time - prior to the subdivision of the parcel into 5 lots, as you voiced concern about in our conversation, could possibly cause problems with the approval of the final subdivision plat. You could do your best to make sure that any house you build now would meet all of the requirements under the current single lot and meet all of the requirements of the future subdivision. However, until the final plat is actually approved I can not tell you that what you submitted in the preliminary plat will be the final configuration of the 5 lot subdivision, or that there may or may not be modifications to the proposed public road that could impact things. 3. With that being said, it is up to you whether to take that risk or not. I would say if the building is approved prior to the final plat being approved then the existing house location, driveway, or other improvements will need to be shown on the final plat so that we can ensure that all regulations are met. 4. One thing in reference to changes I already know will need to take place on the final subdivision plat, because of what was shown on the road plan, is that your proposed public street is now shown at being wider than was shown on the preliminary subdivision plat. Because of this there is some chance that once we get to the final subdivision plat the additional width of right of way could drop one or more lots down to below 2 acres minimum. If this happens the proposed lot lines may need to shift. Until that street right of way width is finalized and approved by all concerned, and the lot sized revised (if necessary) to ensure that the lots all meet the minimum lot standards, there is some chance it could impact where the residences will need to be located. Thanks, Paty Saternye Senior Planner Community Development 4A i ? pI •� Vr Albemarle County 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternye@albemarle.org www.albemarle.org From: Patricia Saternye Sent: Tuesday, April 23, 2019 11:44 AM To: Emily Cox <ecox2@albemarle.org>; Clint Shifflett <Clint.Shifflett@timmons.com> Cc: kitelingerl@yahoo.com Subject: RE: Planning Application Review for SUB201900031 EARLYSVILLE SUBDIVISION - ROAD PLANS. Emily & Clint, Attached please find the planning comments for SUB201900031 EARLYSVILLE SUBDIVISION - ROAD PLANS. I apologize for these not being available when the other review comments went out late last week. Thanks, Paty Saternye Senior Planner Community Development 21 Albemarle County 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternve@albemarle.ore www.albemarle.org From: Emily Cox Sent: Thursday, April 18, 2019 10:30 AM To: Clint Shifflett <Clint.Shifflett@timmons.com>; kitelingerl@vahoo.com Cc: Patricia Saternye <psaternve@albemarle.org> Subject: Planning Application Review for SUB201900031 EARLYSVILLE SUBDIVISION - ROAD PLANS. Clint — See attached. Please note that this is still under review by planning as noted in the comment letter. Let us know if you have any questions. Thanks! The Review for the following application has been completed: Application Number = SUB201900031 Reviewer= Emily Cox Review Status = Requested Changes Completed Date = 04/18/2019 This email was sent from County View Production. 22 Patricia "Paty" Saternye From: Jeffrey Baker Sent: Monday, April 29, 2019 9:32 AM To: Patricia Saternye Subject: FW: Earlysville Hey Paty, Is this the one you prepped me on? What's the application number for his subdivision? Jeff From: luke kitelinger <kiteIingerl@yahoo.com> Sent: Friday, April 26, 2019 8:07 PM To: Jeffrey Baker <jbaker@albemarle.org> Subject: Re: Earlysville Jeff Good Evening I planning on subdividing the property into 5 lots. With that doing said I would like to build on one of the lots. I have talked to Patty about this and she forward me to you. Should be a big deal check wanted to check. Thanks Luke On Thursday, April 25, 2019 1:10 PM, Jeffrey Baker <Ibakerna.albemarle.org> wrote: Luke, Perhaps I can take a shot at assisting you over the phone or by e-mail first? Can you provide me with an address or Parcel number and let me know what you plan on doing? Or is there an existing permit we have in our system? The reason I suggest this is that there may be questions I am unable to answer that I would forward to others. Thanks, Jeff P. Baker Building Permit Planner Albemarle County Department of Community Development 401 McIntire Road Charlottesville, VA 22902 434-296-5832 x 3024 0baker(a-)albemarle.org From: luke kitelinger <kitelinger1(a)_yahoo.com> Sent: Thursday, April 25, 2019 12:54 PM To: Jeffrey Baker <ibaker(Walbemarle.orp Subject: Earlysville 23 Jeff Good afternoon I have 18 acres on Earlysville rd and would like to talk to you about a building permit. Could you please let me know when would be a good time to come in and see you. Thanks Luke Kitelinger 24 Patricia "Paty" Saternye From: Cisco Unity Connection Messaging System <unityconnection@cobm- cucxnpub.albemarle.org> Sent: Wednesday, April 24, 2019 11:25 AM To: psaternye@cobm-cucxnpub.albemarle.org Subject: Message from VIRGINIA CALL (94349603085) Attachments: VoiceMessage.wav Categories: ViewMail 25 Patricia "Paty" Saternye From: John Anderson Sent: Thursday, March 7, 2019 11A2 AM To: Patricia Saternye Subject: RE: Planning Application Review for SUB201800177 PROPERTY OF BELLA SIGNATURE HOMES, LLC - PRELIMINARY. [ Tier III Groundwater Assessment -Engineering Review ] You're welcome, and yes, located there, as well From: Patricia Saternye Sent: Thursday, March 07, 2019 11:23 AM To: John Anderson <janderson2@albemarle.org> Subject: RE: Planning Application Review for SUB201800177 PROPERTY OF BELLA SIGNATURE HOMES, LLC - PRELIMINARY. [ Tier III Groundwater Assessment -Engineering Review ] John, Thanks �. And I think what we discussed is once we have the Final Plat project number that it will be located there as well, right? Thanks, Paty Saternye Senior Planner Community Development � of ;4 U ,`��R41M�*• Albemarle County 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternve@albemarle.ore www.albemarle.ora From: John Anderson Sent: Thursday, March 07, 2019 11:05 AM To: Patricia Saternye <psaternve@albemarle.ore> Subject: Planning Application Review for SUB201800177 PROPERTY OF BELLA SIGNATURE HOMES, LLC - PRELIMINARY. [ Tier III Groundwater Assessment -Engineering Review ] The Review for the following application has been completed: Application Number = SUB201800177 Reviewer = John Anderson Review Status = Requested Changes Completed Date = 03/07/2019 26 This email was sent from County View Production. Paty, Attached Engineering review comments of the Tier III Groundwater Assessment report is for now located with preliminary plat (CV), but Engineering will upload to final plat (CV file #), once FPT received, and file # established for FPT. Please share with applicant at your convenience. Thanks best, JA 0 1.5 Text of review comments: Engineering review of Tier III GW Assessment report is complete. SUB2018-00177 1. Tier III Groundwater Assessment: Albemarle County Parcel #45-59M for Bella Signature Homes. LLC. dated 1/29/19, is comprehensive, but is not approved. 2. Findings detail efforts to obtain well data from VDH, but VDH, as of report date, has been non -responsive to FOIA request for detailed well and septic records for parcels located up to 1000-feet beyond the property lines (ref. ACDSM, Sec. 2.D.l.a.l.d.). Table 1 (p. 5, report), Summary of Available Well Records, indicates the average yield of seventeen (17) well records for wells located within a 0.5 mile radius of the property is 12.9 gpm. See. 7.0, Conclusions (p. 6, report) states, "VDH regulations require a minimum yield of 3 gpm for private residential water supply wells, while Sec. 6.0, Assessment of Well Drilling and Testing, states, "Based on this study, the Site lies in an area capable ofproducing groundwater yield sufficient to meet the demands of the proposed Site development; however, the actual yields of future onsite supply wells cannot be known until the wells are drilled and properly tested" [Emphasis added.] 3. The only well listed in Table 1 located within one thousand feet of the parcel yields 2 91)m. The Tier III report states, "Standard practice for development of water supply wells involves drilling into water bearing zones in the fractured bedrock and sealing off the overburden with a solid well casing. Thus, the ultimate performance of individual water wells in the Blue Ridge Province typically depends on the borehole encountering sufficiently interconnected bedrock fractures. A dry hole results if a well is drilled into bedrock with insufficient fracturing. Fracture occurrence and density depend on a number of factors including specific location, rock type, and site -specific geologic conditions. Because groundwater occurs in discrete fractured zones, it is not unusual to find variability in yields for wells in close proximity to each other. Because the regolith provides groundwater storage, a thicker mantle of overburden usually suggests more favorable conditions for sustainable long-term groundwater withdrawals." (p. 3, emphasis added). 4. Attachment D Water Budget Calculations for Tier III GW Assessment (Albemarle Co. Parcel #45-59M), rounding difference: If use .0015 feet vs .00147 as average regional daily groundwater recharge value, this increases the post - development groundwater surplus report value by a negligible amount (=2%). Attachment D projects 13244 and sumlus (post -development). For comparison, a household of five is estimated to consume 500 gpd, and the proposed five additional households in the watershed are included (subtracted) when calculating the 13,244 gpd surplus (if use .00147, surplus value decreases slightly to=12,851 gpd). Attachment D calculations may assume 1,000' x 20' principal access /road, may apportion 9,068 ft2 new impervious area per lot. Even allowing 100' x 12' stone or paved driveway allows 7,868 ftZ of impervious roof, walk, etc., per lot, which is conservative. Attachment D appears reasonable and accurate, and is accepted. 5. Report assessment of well drilling and testing, spatial variability of well yields, the relative lack of yield data within 1,000' radius of the parcel, requires test well results: a. Engineering recommends HydroGeo Environmental coordinate with Applicant, select a test drill location coincident with the proposed well site location evaluated (for reasons HydroGeo should outline for Engineering) to have low if not lowest potential well yield, and provide well test results in accord with VDH well test protocol. Should this test well yield at least 3 gpm, Engineering will approve the Tier III Groundwater Assessment. The only VDH available 27 data within 1,000 of the parcel to be subdivided yields 2gpm, which is insufficient for VDH permitting purposes. Additional site -specific data is required to advance the final subdivision plat. b. Alternative to item 5.a.: If proposed location rated least likely to yield 3 gpm does not yield 3 gpm, Applicant should test a second of the five well sites for this 5-lot subdivision (ref. report /sketch —Attachment A), and may choose a proposed well site evaluated most favorable, perform well test, and average the two well test values. If this approach does not yield an average >_ 3 gpm, then Applicant may persuade Albemarle that each of the proposed subdivided lots has reasonable chance of encountering subsurface flow sufficient to support required 3 gpm, but this would seem doubtful. Water budget calculations have little to do with peril faced by property owners unable to establish a well supply that yields 3 gpm. Yields are influenced by chance, and additional site -specific information is required prior to Tier III GW Assessment Report approval. 6. Minor: Reduced -size plat /sketch scales are inaccurate. Include note that defines accurate scale, or revise plat sketches included with report using hand -notation to indicate an accurate scale so that a reader may refer to scale, and acquire accurate length or distance information from plats included with the report. Please call Engineering at 434.296-5832 -0069 if any questions. Thank you 28 Patricia "Paty" Saternye From: Patricia Saternye Sent: Thursday, March 7, 2019 11:23 AM To: John Anderson Subject: RE: Planning Application Review for SUB201800177 PROPERTY OF BELLA SIGNATURE HOMES, LLC - PRELIMINARY. [ Tier III Groundwater Assessment -Engineering Review ] John, Thanks Q. And I think what we discussed is once we have the Final Plat project number that it will be located there as well, right? Thanks, Paty Saternye Senior Planner Community Development a °� " =4 :a tn*I Albemarle County 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternve@albemarle.ore www.albemarle.org From: John Anderson Sent: Thursday, March 07, 2019 11:05 AM To: Patricia Saternye <psaternye@albemarle.org> Subject: Planning Application Review for SUB201800177 PROPERTY OF BELLA SIGNATURE HOMES, LLC - PRELIMINARY. [ Tier III Groundwater Assessment -Engineering Review ] The Review for the following application has been completed: Application Number = SUB201800177 Reviewer = John Anderson Review Status = Requested Changes Completed Date = 03/07/2019 This email was sent from County View Production. Paty, Attached Engineering review comments of the Tier III Groundwater Assessment report is for now located with preliminary plat (CV), but Engineering will upload to final plat (CV file #), once FPT received, and file # established for FPT. Please share with applicant at your convenience. Thanks 29 best, JA x3069 Text of review comments: Engineering review of Tier III GW Assessment report is complete. SUB2018-00177 1. Tier III Groundwater Assessment: Albemarle County Parcel #45-59M for Bella Signature Homes, LLC, dated 1/29/19, is comprehensive, but is not approved. 2. Findings detail efforts to obtain well data from VDH, but VDH, as of report date, has been non -responsive to FOIA request for detailed well and septic records for parcels located up to 1000-feet beyond the property lines (ref. ACDSM, Sec. 2.D.l.a.l.d.). Table 1 (p. 5, report), Summary of Available Well Records, indicates the average yield of seventeen (17) well records for wells located within a 0.5 mile radius of the property is 12.9 gpm. Sec. 7.0, Conclusions (p. 6, report) states, "VDH regulations require a minimum yield of 3 gum for private residential water supply wells, while Sec. 6.0, Assessment of Well Drilling and Testing, states, "Based on this study, the Site lies in an area capable ofproducing groundwater yield sufficient to meet the demands of the proposed Site development; however, the actual yields of future onsite supply wells cannot be known until the wells are drilled and properly tested." [Emphasis added.] 3. The only well listed in Table 1 located within one thousand feet of the parcel yields 2 gum. The Tier III report states, "Standard practice for development of water supply wells involves drilling into water bearing zones in the fractured bedrock and sealing off the overburden with a solid well casing. Thus, the ultimate performance of individual water wells in the Blue Ridge Province typically depends on the borehole encountering sufficiently interconnected bedrock fractures. A dry hole results if a well is drilled into bedrock with insufficient fracturing. Fracture occurrence and density depend on a number of factors including specific location, rock type, and site -specific geologic conditions. Because groundwater occurs in discrete fractured zones, it is not unusual to find variability in yields for wells in close proximity to each other. Because the regolith provides groundwater storage, a thicker mantle of overburden usually suggests more favorable conditions for sustainable long-term groundwater withdrawals." (p. 3, emphasis added). 4. Attachment D Water Budget Calculations for Tier III GW Assessment (Albemarle Co. Parcel #45-59M), rounding difference: If use .0015 feet vs .00147 as average regional daily groundwater recharge value, this increases the post - development groundwater surplus report value by a negligible amount (-2%). Attachment D projects 13244 god sumlus (post -development). For comparison, a household of five is estimated to consume 500 gpd, and the proposed five additional households in the watershed are included (subtracted) when calculating the 13,244 gpd surplus (if use .00147, surplus value decreases slightly to-12,851 gpd). Attachment D calculations may assume 1,000' x 20' principal access /road, may apportion 9,068 ft2 new impervious area per lot. Even allowing 100' x 12' stone or paved driveway allows 7,868 ft2 of impervious roof, walk, etc., per lot, which is conservative. Attachment D appears reasonable and accurate, and is accepted. 5. Report assessment of well drilling and testing, spatial variability of well yields, the relative lack of yield data within 1,000' radius of the parcel, requires test well results: a. Engineering recommends HydroGeo Environmental coordinate with Applicant, select a test drill location coincident with the proposed well site location evaluated (for reasons HydroGeo should outline for Engineering) to have low if not lowest potential well yield, and provide well test results in accord with VDH well test protocol. Should this test well yield at least 3 gpm, Engineering will approve the Tier III Groundwater Assessment. The only VDH available data within 1,000 of the parcel to be subdivided yields 2gpm, which is insufficient for VDH permitting purposes. Additional site -specific data is required to advance the final subdivision plat. b. Alternative to item 5.a.: If proposed location rated least likely to yield 3 gpm does not yield 3 gpm, Applicant should test a second of the five well sites for this 5-lot subdivision (ref. report /sketch —Attachment A), and may choose a proposed well site evaluated most favorable, perform well test, and average the two well test values. If this approach does not yield an average >_ 3 gpm, then Applicant may persuade Albemarle that each of the proposed subdivided lots has reasonable chance of encountering subsurface flow sufficient to support required 3 gpm, but this would seem doubtful. Water budget calculations have little to do with peril faced by property owners unable to establish a well supply that yields 3 gpm. Yields are influenced by chance, and additional site -specific information is required prior to Tier III GW Assessment Report approval. 30 6. Minor: Reduced -size plat /sketch scales are inaccurate. Include note that defines accurate scale, or revise plat sketches included with report using hand -notation to indicate an accurate scale so that a reader may refer to scale, and acquire accurate length or distance information from plats included with the report. Please call Engineering at 434.296-5832 -0069 if any questions. Thank you 31 Patricia "Paty" Saternye From: Patricia Saternye Sent: Thursday, March 7, 2019 11:23 AM To: John Anderson Subject: RE: Planning Application Review for SUB201800177 PROPERTY OF BELLA SIGNATURE HOMES, LLC - PRELIMINARY. [ Tier III Groundwater Assessment -Engineering Review ] John, Thanks Q. And I think what we discussed is once we have the Final Plat project number that it will be located there as well, right? Thanks, Paty Saternye Senior Planner Community Development a °� " =4 :a tn*I Albemarle County 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternve@albemarle.ore www.albemarle.org From: John Anderson Sent: Thursday, March 07, 2019 11:05 AM To: Patricia Saternye <psaternye@albemarle.org> Subject: Planning Application Review for SUB201800177 PROPERTY OF BELLA SIGNATURE HOMES, LLC - PRELIMINARY. [ Tier III Groundwater Assessment -Engineering Review ] The Review for the following application has been completed: Application Number = SUB201800177 Reviewer = John Anderson Review Status = Requested Changes Completed Date = 03/07/2019 This email was sent from County View Production. Paty, Attached Engineering review comments of the Tier III Groundwater Assessment report is for now located with preliminary plat (CV), but Engineering will upload to final plat (CV file #), once FPT received, and file # established for FPT. Please share with applicant at your convenience. Thanks 32 best, JA x3069 Text of review comments: Engineering review of Tier III GW Assessment report is complete. SUB2018-00177 1. Tier III Groundwater Assessment: Albemarle County Parcel #45-59M for Bella Signature Homes, LLC, dated 1/29/19, is comprehensive, but is not approved. 2. Findings detail efforts to obtain well data from VDH, but VDH, as of report date, has been non -responsive to FOIA request for detailed well and septic records for parcels located up to 1000-feet beyond the property lines (ref. ACDSM, Sec. 2.D.l.a.l.d.). Table 1 (p. 5, report), Summary of Available Well Records, indicates the average yield of seventeen (17) well records for wells located within a 0.5 mile radius of the property is 12.9 gpm. Sec. 7.0, Conclusions (p. 6, report) states, "VDH regulations require a minimum yield of 3 gum for private residential water supply wells, while Sec. 6.0, Assessment of Well Drilling and Testing, states, "Based on this study, the Site lies in an area capable ofproducing groundwater yield sufficient to meet the demands of the proposed Site development; however, the actual yields of future onsite supply wells cannot be known until the wells are drilled and properly tested." [Emphasis added.] 3. The only well listed in Table 1 located within one thousand feet of the parcel yields 2 gum. The Tier III report states, "Standard practice for development of water supply wells involves drilling into water bearing zones in the fractured bedrock and sealing off the overburden with a solid well casing. Thus, the ultimate performance of individual water wells in the Blue Ridge Province typically depends on the borehole encountering sufficiently interconnected bedrock fractures. A dry hole results if a well is drilled into bedrock with insufficient fracturing. Fracture occurrence and density depend on a number of factors including specific location, rock type, and site -specific geologic conditions. Because groundwater occurs in discrete fractured zones, it is not unusual to find variability in yields for wells in close proximity to each other. Because the regolith provides groundwater storage, a thicker mantle of overburden usually suggests more favorable conditions for sustainable long-term groundwater withdrawals." (p. 3, emphasis added). 4. Attachment D Water Budget Calculations for Tier III GW Assessment (Albemarle Co. Parcel #45-59M), rounding difference: If use .0015 feet vs .00147 as average regional daily groundwater recharge value, this increases the post - development groundwater surplus report value by a negligible amount (-2%). Attachment D projects 13244 god sumlus (post -development). For comparison, a household of five is estimated to consume 500 gpd, and the proposed five additional households in the watershed are included (subtracted) when calculating the 13,244 gpd surplus (if use .00147, surplus value decreases slightly to-12,851 gpd). Attachment D calculations may assume 1,000' x 20' principal access /road, may apportion 9,068 ft2 new impervious area per lot. Even allowing 100' x 12' stone or paved driveway allows 7,868 ft2 of impervious roof, walk, etc., per lot, which is conservative. Attachment D appears reasonable and accurate, and is accepted. 5. Report assessment of well drilling and testing, spatial variability of well yields, the relative lack of yield data within 1,000' radius of the parcel, requires test well results: a. Engineering recommends HydroGeo Environmental coordinate with Applicant, select a test drill location coincident with the proposed well site location evaluated (for reasons HydroGeo should outline for Engineering) to have low if not lowest potential well yield, and provide well test results in accord with VDH well test protocol. Should this test well yield at least 3 gpm, Engineering will approve the Tier III Groundwater Assessment. The only VDH available data within 1,000 of the parcel to be subdivided yields 2gpm, which is insufficient for VDH permitting purposes. Additional site -specific data is required to advance the final subdivision plat. b. Alternative to item 5.a.: If proposed location rated least likely to yield 3 gpm does not yield 3 gpm, Applicant should test a second of the five well sites for this 5-lot subdivision (ref. report /sketch —Attachment A), and may choose a proposed well site evaluated most favorable, perform well test, and average the two well test values. If this approach does not yield an average >_ 3 gpm, then Applicant may persuade Albemarle that each of the proposed subdivided lots has reasonable chance of encountering subsurface flow sufficient to support required 3 gpm, but this would seem doubtful. Water budget calculations have little to do with peril faced by property owners unable to establish a well supply that yields 3 gpm. Yields are influenced by chance, and additional site -specific information is required prior to Tier III GW Assessment Report approval. 33 6. Minor: Reduced -size plat /sketch scales are inaccurate. Include note that defines accurate scale, or revise plat sketches included with report using hand -notation to indicate an accurate scale so that a reader may refer to scale, and acquire accurate length or distance information from plats included with the report. Please call Engineering at 434.296-5832 -0069 if any questions. Thank you 34 Patricia "Paty" Saternye From: John Anderson Sent: Thursday, March 7, 2019 11:05 AM To: Patricia Saternye Subject: Planning Application Review for SUB201800177 PROPERTY OF BELLA SIGNATURE HOMES, LLC - PRELIMINARY. [ Tier III Groundwater Assessment -Engineering Review ] Attachments: SUB201800177 Bella Signature GWA 030719.pdf The Review for the following application has been completed: Application Number = SUB201800177 Reviewer = John Anderson Review Status = Requested Changes Completed Date = 03/07/2019 This email was sent from County View Production. Paty, Attached Engineering review comments of the Tier III Groundwater Assessment report is for now located with preliminary plat (CV), but Engineering will upload to final plat (CV file #), once FPT received, and file # established for FPT. Please share with applicant at your convenience. Thanks best, JA x3069 Text of review comments: Engineering review of Tier III GW Assessment report is complete. SUB2018-00177 1. Tier III Groundwater Assessment: Albemarle County Parcel #45-59M for Bella Signature Homes, LLC, dated 1/29/19, is comprehensive, but is not approved. 2. Findings detail efforts to obtain well data from VDH, but VDH, as of report date, has been non -responsive to FOIA request for detailed well and septic records for parcels located up to 1000-feet beyond the property lines (ref. ACDSM, Sec. 2.D.l.a.l.d.). Table 1 (p. 5, report), Summary of Available Well Records, indicates the average yield of seventeen (17) well records for wells located within a 0.5 mile radius of the property is 12.9 gpm. Sec. 7,0, Conclusions (p. 6, report) states, "VDH regulations require a minimum yield of 3 gpm for private residential water supply wells, while Sec. 6.0, Assessment of Well Drilling and Testing, states, "Based on this study, the Site lies in an area capable ofproducing groundwater yield sufficient to meet the demands of the proposed Site development, however, the actual yields of future onsite supply wells cannot be known until the wells are drilled and properly tested" [Emphasis added.] 3. The only well listed in Table 1 located within one thousand feet of the parcel yields 2 gom. The Tier III report states, "Standard practice for development of water supply wells involves drilling into water bearing zones in the fractured bedrock and sealing off the overburden with a solid well casing. Thus, the ultimate performance of individual water wells in the Blue Ridge Province typically depends on the borehole encountering sufficiently interconnected bedrock fractures. A dry hole results if a well is drilled into bedrock with insufficient fracturing. Fracture occurrence and density depend on a number of 35 factors including specific location, rock type, and site -specific geologic conditions. Because groundwater occurs in discrete fractured zones, it is not unusual to find variability in yields for wells in close proximity to each other. Because the regolith provides groundwater storage, a thicker mantle of overburden usually suggests more favorable conditions for sustainable long-term groundwater withdrawals." (p. 3, emphasis added). 4. Attachment D Water Budget Calculations for Tier III GW Assessment (Albemarle Co. Parcel #45-59M), rounding difference: If use .0015 feet vs .00147 as average regional daily groundwater recharge value, this increases the post - development groundwater surplus report value by a negligible amount (-2%). Attachment D projects 13244 gpd surplus (post -development). For comparison, a household of five is estimated to consume 500 gpd, and the proposed five additional households in the watershed are included (subtracted) when calculating the 13,244 gpd surplus (if use .00147, surplus value decreases slightly to-12,851 gpd). Attachment D calculations may assume 1,000' x 20' principal access /road, may apportion 9,068 ft2 new impervious area per lot. Even allowing 100' x 12' stone or paved driveway allows 7,868 ftZ of impervious roof, walk, etc., per lot, which is conservative. Attachment D appears reasonable and accurate, and is accepted. 5. Report assessment of well drilling and testing, spatial variability of well yields, the relative lack of yield data within 1,000' radius of the parcel, requires test well results: a. Engineering recommends HydroGeo Environmental coordinate with Applicant, select a test drill location coincident with the proposed well site location evaluated (for reasons HydroGeo should outline for Engineering) to have low if not lowest potential well yield, and provide well test results in accord with VDH well test protocol. Should this test well yield at least 3 gpm, Engineering will approve the Tier III Groundwater Assessment. The only VDH available data within 1,000 of the parcel to be subdivided yields 2apm, which is insufficient for VDH permitting purposes. Additional site -specific data is required to advance the final subdivision plat. b. Alternative to item 5.a.: If proposed location rated least likely to yield 3 gpm does not yield 3 gpm, Applicant should test a second of the five well sites for this 5-lot subdivision (ref. report /sketch —Attachment A), and may choose a proposed well site evaluated most favorable, perform well test, and average the two well test values. If this approach does not yield an average >_ 3 gpm, then Applicant may persuade Albemarle that each of the proposed subdivided lots has reasonable chance of encountering subsurface flow sufficient to support required 3 gpm, but this would seem doubtful. Water budget calculations have little to do with peril faced by property owners unable to establish a well supply that yields 3 gpm. Yields are influenced by chance, and additional site -specific information is required prior to Tier III GW Assessment Report approval. 6. Minor: Reduced -size plat /sketch scales are inaccurate. Include note that defines accurate scale, or revise plat sketches included with report using hand -notation to indicate an accurate scale so that a reader may refer to scale, and acquire accurate length or distance information from plats included with the report. Please call Engineering at 434.296-5832 -0069 if any questions. Thank you 36 Patricia "Paty" Saternye From: John Anderson Sent: Thursday, March 7, 2019 11:05 AM To: Patricia Saternye Subject: Planning Application Review for SUB201800177 PROPERTY OF BELLA SIGNATURE HOMES, LLC - PRELIMINARY. [ Tier III Groundwater Assessment -Engineering Review ] Attachments: SUB201800177 Bella Signature GWA 030719.pdf The Review for the following application has been completed: Application Number = SUB201800177 Reviewer = John Anderson Review Status = Requested Changes Completed Date = 03/07/2019 This email was sent from County View Production. Paty, Attached Engineering review comments of the Tier III Groundwater Assessment report is for now located with preliminary plat (CV), but Engineering will upload to final plat (CV file #), once FPT received, and file # established for FPT. Please share with applicant at your convenience. Thanks best, JA x3069 Text of review comments: Engineering review of Tier III GW Assessment report is complete. SUB2018-00177 1. Tier III Groundwater Assessment: Albemarle County Parcel #45-59M for Bella Signature Homes, LLC, dated 1/29/19, is comprehensive, but is not approved. 2. Findings detail efforts to obtain well data from VDH, but VDH, as of report date, has been non -responsive to FOIA request for detailed well and septic records for parcels located up to 1000-feet beyond the property lines (ref. ACDSM, Sec. 2.D.l.a.l.d.). Table 1 (p. 5, report), Summary of Available Well Records, indicates the average yield of seventeen (17) well records for wells located within a 0.5 mile radius of the property is 12.9 gpm. Sec. 7,0, Conclusions (p. 6, report) states, "VDH regulations require a minimum yield of 3 gpm for private residential water supply wells, while Sec. 6.0, Assessment of Well Drilling and Testing, states, "Based on this study, the Site lies in an area capable ofproducing groundwater yield sufficient to meet the demands of the proposed Site development, however, the actual yields of future onsite supply wells cannot be known until the wells are drilled and properly tested" [Emphasis added.] 3. The only well listed in Table 1 located within one thousand feet of the parcel yields 2 gom. The Tier III report states, "Standard practice for development of water supply wells involves drilling into water bearing zones in the fractured bedrock and sealing off the overburden with a solid well casing. Thus, the ultimate performance of individual water wells in the Blue Ridge Province typically depends on the borehole encountering sufficiently interconnected bedrock fractures. A dry hole results if a well is drilled into bedrock with insufficient fracturing. Fracture occurrence and density depend on a number of 37 factors including specific location, rock type, and site -specific geologic conditions. Because groundwater occurs in discrete fractured zones, it is not unusual to find variability in yields for wells in close proximity to each other. Because the regolith provides groundwater storage, a thicker mantle of overburden usually suggests more favorable conditions for sustainable long-term groundwater withdrawals." (p. 3, emphasis added). 4. Attachment D Water Budget Calculations for Tier III GW Assessment (Albemarle Co. Parcel #45-59M), rounding difference: If use .0015 feet vs .00147 as average regional daily groundwater recharge value, this increases the post - development groundwater surplus report value by a negligible amount (-2%). Attachment D projects 13244 gpd surplus (post -development). For comparison, a household of five is estimated to consume 500 gpd, and the proposed five additional households in the watershed are included (subtracted) when calculating the 13,244 gpd surplus (if use .00147, surplus value decreases slightly to-12,851 gpd). Attachment D calculations may assume 1,000' x 20' principal access /road, may apportion 9,068 ft2 new impervious area per lot. Even allowing 100' x 12' stone or paved driveway allows 7,868 ftZ of impervious roof, walk, etc., per lot, which is conservative. Attachment D appears reasonable and accurate, and is accepted. 5. Report assessment of well drilling and testing, spatial variability of well yields, the relative lack of yield data within 1,000' radius of the parcel, requires test well results: a. Engineering recommends HydroGeo Environmental coordinate with Applicant, select a test drill location coincident with the proposed well site location evaluated (for reasons HydroGeo should outline for Engineering) to have low if not lowest potential well yield, and provide well test results in accord with VDH well test protocol. Should this test well yield at least 3 gpm, Engineering will approve the Tier III Groundwater Assessment. The only VDH available data within 1,000 of the parcel to be subdivided yields 2apm, which is insufficient for VDH permitting purposes. Additional site -specific data is required to advance the final subdivision plat. b. Alternative to item 5.a.: If proposed location rated least likely to yield 3 gpm does not yield 3 gpm, Applicant should test a second of the five well sites for this 5-lot subdivision (ref. report /sketch —Attachment A), and may choose a proposed well site evaluated most favorable, perform well test, and average the two well test values. If this approach does not yield an average >_ 3 gpm, then Applicant may persuade Albemarle that each of the proposed subdivided lots has reasonable chance of encountering subsurface flow sufficient to support required 3 gpm, but this would seem doubtful. Water budget calculations have little to do with peril faced by property owners unable to establish a well supply that yields 3 gpm. Yields are influenced by chance, and additional site -specific information is required prior to Tier III GW Assessment Report approval. 6. Minor: Reduced -size plat /sketch scales are inaccurate. Include note that defines accurate scale, or revise plat sketches included with report using hand -notation to indicate an accurate scale so that a reader may refer to scale, and acquire accurate length or distance information from plats included with the report. Please call Engineering at 434.296-5832 -0069 if any questions. Thank you 38 Patricia "Paty" Saternye From: John Anderson Sent: Thursday, January 31, 2019 6:03 PM To: Patricia Saternye Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes (SUB2018-177 - Preliminary Plat) Right, no, they didn't ask that I prioritize review. I don't mind entering comments under both numbers, and will be sure to enter Engineering review of GW Tier III report with Final Plat, whenever submitted and SUB# assigned. Thanks —very thoughtful, Paty From: Patricia Saternye Sent: Thursday, January 31, 2019 2:37 PM To: John Anderson <janderson2@albemarle.org> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes (SUB2018-177 - Preliminary Plat) John, It is up to you. The only two things I would say is that: • There is no rush since it is supposed to be reviewed with the final plat. So unless you have availability I wouldn't prioritize it (They didn't ask for it to be reviewed ASAP did they? • Putting it in the Preliminary Plat folder could cause confusion later, unless you ultimately want to upload it under both numbers. Thanks, Paty Saternye Senior Planner Community Development Albemarle County 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternye@albemarle.ore www.albemarle.ora From: John Anderson Sent: Thursday, January 31, 2019 1:26 PM To: Patricia Saternye <psaternye@albemarle.ore> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes (SUB2018-177 - Preliminary Plat) Paty, thanks 39 I thought to review the Tier III report under preliminary plat since final plat not yet submitted, Tier III submitted, and to try to keep track... a CV location to list review, more than anything else. Later, I can include ref. to location of review of final Tier III report, under the final plat /SUB#. Does this make sense? Thoughts? From: Patricia Saternye Sent: Thursday, January 31, 2019 12:58 PM To: John Anderson <landerson2@albemarle.ora> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes (SUB2018-177 - Preliminary Plat) My comment #1 (attached) states that they were supposed to submit the draft study prior to the preliminary plat approval, that they did, and to see your comments the draft report that was submitted. So, if they did it correctly, what is attached should be the revised and final version of the study that is supposed to be submitted with the final plat. Thanks, Paty Saternye Senior Planner Community Development Albemarle County 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternve@albemarle.ore www.albemarle.org From: John Anderson Sent: Thursday, January 31, 2019 12:53 PM To: Patricia Saternye <psaternve@albemarle.ora> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes thanks From: Patricia Saternye Sent: Thursday, January 31, 2019 12:52 PM To: John Anderson <landerson2@albemarle.ora> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes John, I would have to look back at the comments, but if the preliminary is approved it might not be necessary to review the Tier III until the final plat is submitted. I'll try to look at that later today or tomorrow morning. Thanks, 0 Paty Saternye Senior Planner Community Development 4y OF _ r U f yl *I. M Albemarle County 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternye@albemarle.org www.albemarle.org From: John Anderson Sent: Thursday, January 31, 2019 12:44 PM To: Patricia Saternye <psaternve@albemarle.org> Cc: Ernest Beasley<ebeasley@hydrogeoenvironmental.com> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes Paty, No, a single fee is sufficient. I will review the digital Tier III report as soon as possible, and have added a task under preliminary subdivision plat —thanks, Paty. Mr. Beasley, The report is logged /in my review queue. I will review as soon as possible and withdraw request for an application related to GW assessment —thanks for sending. -best, J. Anderson 434.296-5832 -x3069 From: Patricia Saternye Sent: Thursday, January 31, 2019 12:36 PM To: John Anderson <janderson2@albemarle.org> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes John, It appears on County View that the Fee for the Tier III Groundwater Study, for the approved SUB2018-177 Properties of Bella Signature Homes PRELIMINARY Plat, has been previously paid. Unless there is a new/different fee at the Final Plat stage, on top of the one at the Preliminary, he may not owe it. I'm not sure if there is a second fee, but I don't think there is... maybe we should ask Matt. I have not received the final plat submission yet... Thanks, Paty Saternye Senior Planner Community Development 41 Albemarle County 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternve@albemarle.org www.albemarle.org From: John Anderson Sent: Thursday, January 31, 2019 12:29 PM To: Ernest Beasley <ebeaslev@hvdrogeoenvironmental.com> Cc: Patricia Saternye <psaternve@albemarle.org> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes (Paty, please advise —thanks ) Thanks for your email, Mr. Beasley. Please submit a subdivision application (with fee) with print copy of Tier III report to get into review queues. Since this is a subdivision application, I rely on Paty for guidance. It appears a 548 fee is required with Application (image, below: pg. 3 /Application) Groundwater Re►•ien, Fees J 'Pier 2 Groundwater Res•ic,#% = $355 (Required for all plats proposing lots less than 21 acre, J 'Pier 3 Groundwater Revietr = $948 (Required for all plats proposing lots where at least 3 1 acres or Icss) J 'I'ier 4 Groundwater Review = $1,183 Link to Application: http://www.albemarle.org/upload/itnagestforrns_center/departments/Commim4 Development/forms/applications/Subdiv ision Plat & Checklist.odf I look forward to receiving a print copy of the Tier 3 report, once submitted with Application. Thanks again -best, J. Anderson 434.296-5832 -x3069 From: Ernest Beasley <ebeaslev@hydrogeoenvironmental.com> Sent: Thursday, January 31, 2019 12:08 PM To: John Anderson <ianderson2@albemarle.org> Cc: Luke Kitelinger <Kitelingerl@vahoo.com>; Bryan Chambers<chamberslandsurveying@vahoo.com>; Kathryn Bryant <Kathryn@hydrogeoenvironmental.com>;1P Ligush<Ipligush@hydrogeoenvironmental.com> Subject: Tier 3 Groundwater Assessment for Bella Signature Homes 42 Mr. Anderson, Please see the attached Tier 3 Groundwater Assessment HydroGeo has completed on behalf of Bella Signature Homes, LLC for Albemarle Parcel #45-59M. Don't hesitate to reach out to me with any questions or comments. Many thanks, Bubba Beasley, MS, CPG Geologist c: (404) 219-6676 www.HvdroGeoEnvironmental.com 43 Patricia "Paty" Saternye From: Patricia Saternye Sent: Thursday, January 31, 2019 2:37 PM To: John Anderson Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes (SUB2018-177 - Preliminary Plat) John, It is up to you. The only two things I would say is that: • There is no rush since it is supposed to be reviewed with the final plat. So unless you have availability I wouldn't prioritize it (They didn't ask for it to be reviewed ASAP did they? • Putting it in the Preliminary Plat folder could cause confusion later, unless you ultimately want to upload it under both numbers. Thanks, Paty Saternye Senior Planner Community Development 4� v �`�/R41N��R� Albemarle County 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternye@albemarle.ore www.albemarle.or� From: John Anderson Sent: Thursday, January 31, 2019 1:26 PM To: Patricia Saternye <psaternye@albemarle.org> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes (SUB2018-177 - Preliminary Plat) Paty, thanks I thought to review the Tier III report under preliminary plat since final plat not yet submitted, Tier III submitted, and to try to keep track... a CV location to list review, more than anything else. Later, I can include ref. to location of review of final Tier III report, under the final plat /SUB#. Does this make sense? Thoughts? From: Patricia Saternye Sent: Thursday, January 31, 2019 12:58 PM To: John Anderson <janderson2@albemarle.ore> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes (SUB2018-177 - Preliminary Plat) M My comment #1(attached) states that they were supposed to submit the draft study prior to the preliminary plat approval, that they did, and to see your comments the draft report that was submitted. So, if they did it correctly, what is attached should be the revised and final version of the study that is supposed to be submitted with the final plat. Thanks, Paty Saternye Senior Planner Community Development ri Albemarle County 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternye@albemarle.org www.albemarle.ors From: John Anderson Sent: Thursday, January 31, 2019 12:53 PM To: Patricia Saternye <psaternve@albemarle.ore> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes thanks From: Patricia Saternye Sent: Thursday, January 31, 2019 12:52 PM To: John Anderson <janderson2@albemarle.ora> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes John, I would have to look back at the comments, but if the preliminary is approved it might not be necessary to review the Tier III until the final plat is submitted. I'll try to look at that later today or tomorrow morning. Thanks, Paty Saternye Senior Planner Community Development Albemarle County 401 McIntire Road Charlottesville, VA 22902 45 434-296-5832 ext.3250 psaternye@albemarle.org www.albemarle.org From: John Anderson Sent: Thursday, January 31, 2019 12:44 PM To: Patricia Saternye <psaternye@albemarle.org> Cc: Ernest Beasley<ebeasley@hydrogeoenvironmental.com> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes Paty, No, a single fee is sufficient. I will review the digital Tier III report as soon as possible, and have added a task under preliminary subdivision plat —thanks, Paty. Mr. Beasley, The report is logged /in my review queue. I will review as soon as possible and withdraw request for an application related to GW assessment —thanks for sending. -best, J. Anderson 434.296-5832 -x3069 From: Patricia Saternye Sent: Thursday, January 31, 2019 12:36 PM To: John Anderson <janderson2@albemarle.org> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes John, It appears on County View that the Fee for the Tier III Groundwater Study, for the approved SUB2018-177 Properties of Bella Signature Homes PRELIMINARY Plat, has been previously paid. Unless there is a new/different fee at the Final Plat stage, on top of the one at the Preliminary, he may not owe it. I'm not sure if there is a second fee, but I don't think there is... maybe we should ask Matt. I have not received the final plat submission yet... Thanks, Paty Saternye Senior Planner Community Development Albemarle County 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternye@albemarle.org www.albemarle.org M From: John Anderson Sent: Thursday, January 31, 2019 12:29 PM To: Ernest Beasley <ebeaslev@hydrogeoenvironmental.com> Cc: Patricia Saternye <psaternye@albemarle.org> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes (Paty, please advise —thanks ) Thanks for your email, Mr. Beasley. Please submit a subdivision application (with fee) with print copy of Tier III report to get into review queues. Since this is a subdivision application, I rely on Paty for guidance. It appears a 548 fee is required with Application (image, below: pg. 3 /Application) Grotrndiraler Review Fees J Tier 2 Groundwater Review = $355 (Required for all plats proposing lots less than 21 acre! J Tier 3 Groundwater Review = $548 (Required for all plats proposing lots where at least 31 acres or less) 0 Tier 4 Groundwater Review = $1,183 Link to Application: http://www.albemarle.or Lupload/itnagestfonns_center/departments/Community Development/forms/applications/Subdiv ision Plat & Cheeklist.odf I look forward to receiving a print copy of the Tier 3 report, once submitted with Application. Thanks again -best, J. Anderson 434.296-5832 -x3069 From: Ernest Beasley <ebeaslev@hydrogeoenvironmental.com> Sent: Thursday, January 31, 2019 12:08 PM To: John Anderson <ianderson2@albemarle.org> Cc: Luke Kitelinger <Kitelingerl@yahoo.com>; Bryan Chambers<chamberslandsurveying@yahoo.com>; Kathryn Bryant <Kathryn@hydrogeoenvironmental.com>;1P Ligush<ipligush@hvdrogeoenvironmental.com> Subject: Tier 3 Groundwater Assessment for Bella Signature Homes Mr. Anderson, Please see the attached Tier 3 Groundwater Assessment HydroGeo has completed on behalf of Bella Signature Homes, LLC for Albemarle Parcel #45-59M. Don't hesitate to reach out to me with any questions or comments. Many thanks, Bubba Beasley, MS, CPG Geologist c: (404) 219-6676 www.HvdroGeoEnvironmental.com 47 Patricia "Paty" Saternye From: John Anderson Sent: Thursday, January 31, 2019 1:26 PM To: Patricia Saternye Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes (SUB2018-177 - Preliminary Plat) Paty, thanks I thought to review the Tier III report under preliminary plat since final plat not yet submitted, Tier III submitted, and to try to keep track... a CV location to list review, more than anything else. Later, I can include ref. to location of review of final Tier III report, under the final plat /SUB#. Does this make sense? Thoughts? From: Patricia Saternye Sent: Thursday, January 31, 2019 12:58 PM To: John Anderson <janderson2@albemarle.org> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes (SUB2018-177 - Preliminary Plat) My comment #1 (attached) states that they were supposed to submit the draft study prior to the preliminary plat approval, that they did, and to see your comments the draft report that was submitted. So, if they did it correctly, what is attached should be the revised and final version of the study that is supposed to be submitted with the final plat. Thanks, Paty Saternye Senior Planner Community Development 4{ Ir A V Albemarle County 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternve@albemarle.ore www.albemarle.or� From: John Anderson Sent: Thursday, January 31, 2019 12:53 PM To: Patricia Saternye <psaternye@albemarle.org> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes thanks 49 From: Patricia Saternye Sent: Thursday, January 31, 2019 12:52 PM To: John Anderson <landerson2@albemarle.org> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes John, I would have to look back at the comments, but if the preliminary is approved it might not be necessary to review the Tier III until the final plat is submitted. I'll try to look at that later today or tomorrow morning. Thanks, Paty Saternye Senior Planner Community Development ail 11 b� A, U !� a��R4 A" Albemarle County 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternye@albemarle.org www.albemarle.org From: John Anderson Sent: Thursday, January 31, 2019 12:44 PM To: Patricia Saternye <psaternve@albemarle.org> Cc: Ernest Beasley<ebeasley@hydrogeoenvironmental.com> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes Paty, No, a single fee is sufficient. I will review the digital Tier III report as soon as possible, and have added a task under preliminary subdivision plat —thanks, Paty. Mr. Beasley, The report is logged /in my review queue. I will review as soon as possible and withdraw request for an application related to GW assessment —thanks for sending. -best, J. Anderson 434.296-5832 -x3069 From: Patricia Saternye Sent: Thursday, January 31, 2019 12:36 PM To: John Anderson <janderson2@albemarle.org> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes 50 John, It appears on County View that the Fee for the Tier III Groundwater Study, for the approved SUB2018-177 Properties of Bella Signature Homes PRELIMINARY Plat, has been previously paid. Unless there is a new/different fee at the Final Plat stage, on top of the one at the Preliminary, he may not owe it. I'm not sure if there is a second fee, but I don't think there is... maybe we should ask Matt. I have not received the final plat submission yet... Thanks, Paty Saternye Senior Planner Community Development 4�Or 2 u ,`��R41M�*• Albemarle County 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternve@albemarle.ore www.albemarle.org From: John Anderson Sent: Thursday, January 31, 2019 12:29 PM To: Ernest Beasley<ebeaslev@hvdroeeoenvironmental.com> Cc: Patricia Saternye <psaternve@albemarle.org> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes (Paty, please advise —thanks ) Thanks for your email, Mr. Beasley. Please submit a subdivision application (with fee) with print copy of Tier III report to get into review queues. Since this is a subdivision application, I rely on Paty for guidance. It appears a 548 fee is required with Application (image, below: pg. 3 /Application) Groundwater Review Fees J Tier 2 Groundwater Review = $355 (Required for all plats proposing lots less than 21 acre! J Tier 3 Groundwater Review = $548 (Required for all plats proposing lots whereat least 31 acres or less) J Tier 4 Groundwater Review = $1,183 Link to Application: http://www.albemarle.or Lupload/itnagestfonns_center/departments/Commim4 Development/forms/applications/Subdiv ision Plat & Checklist.odf 51 I look forward to receiving a print copy of the Tier 3 report, once submitted with Application. Thanks again -best, J. Anderson 434.296-5832 -0069 From: Ernest Beasley<ebeasley@hydrogeoenvironmentaLcom> Sent: Thursday, January 31, 2019 12:08 PM To: John Anderson <janderson2@albemarle.org> Cc: Luke Kitelinger <Kitelinger1@yahoo.com>; Bryan Chambers <chamberslandsurveving@vahoo.com>; Kathryn Bryant <Kathryn@hvdrogeoenvironmental.com>; JP Ligush<ipligush@hvdrogeoenvironmental.com> Subject: Tier 3 Groundwater Assessment for Bella Signature Homes Mr. Anderson, Please see the attached Tier 3 Groundwater Assessment HydroGeo has completed on behalf of Bella Signature Homes, LLC for Albemarle Parcel #45-59M. Don't hesitate to reach out to me with any questions or comments. Many thanks, Bubba Beasley, MS, CPG Geologist c: (404) 219-6676 www.HvdroGeoEnvironmental.com 52 Patricia "Paty" Saternye From: Patricia Saternye Sent: Thursday, January 31, 2019 12:58 PM To: John Anderson Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes (SUB2018-177 - Preliminary Plat) Attachments: SUB2018-177 Approval with Conditions 12-21-2018c.pdf My comment #1(attached) states that they were supposed to submit the draft study prior to the preliminary plat approval, that they did, and to see your comments the draft report that was submitted. So, if they did it correctly, what is attached should be the revised and final version of the study that is supposed to be submitted with the final plat. Thanks, Paty Saternye Senior Planner Community Development pF ;4 U '`��R41M�*I. Albemarle County 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternye@albemarle.org www.albemarle.org From: John Anderson Sent: Thursday, January 31, 2019 12:53 PM To: Patricia Saternye <psaternye@albemarle.org> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes thanks From: Patricia Saternye Sent: Thursday, January 31, 2019 12:52 PM To: John Anderson <janderson2@albemarle.org> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes John, I would have to look back at the comments, but if the preliminary is approved it might not be necessary to review the Tier III until the final plat is submitted. I'll try to look at that later today or tomorrow morning. 53 Thanks, Paty Saternye Senior Planner Community Development Ati �I Albemarle County 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternve@albemarle.ore www.albemarle.or� From: John Anderson Sent: Thursday, January 31, 2019 12:44 PM To: Patricia Saternye <psaternve@albemarle.ore> Cc: Ernest Beasley<ebeaslev@hvdroaeoenvironmental.com> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes Paty, No, a single fee is sufficient. I will review the digital Tier III report as soon as possible, and have added a task under preliminary subdivision plat —thanks, Paty. Mr. Beasley, The report is logged /in my review queue. I will review as soon as possible and withdraw request for an application related to GW assessment —thanks for sending. -best, J. Anderson 434.296-5832 -x3069 From: Patricia Saternye Sent: Thursday, January 31, 2019 12:36 PM To: John Anderson <landerson2@albemarle.ore> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes John, It appears on County View that the Fee for the Tier III Groundwater Study, for the approved SUB2018-177 Properties of Bella Signature Homes PRELIMINARY Plat, has been previously paid. Unless there is a new/different fee at the Final Plat stage, on top of the one at the Preliminary, he may not owe it. I'm not sure if there is a second fee, but I don't think there is... maybe we should ask Matt. I have not received the final plat submission yet... Thanks, Paty Saternye Senior Planner Community Development 54 Albemarle County 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternve@albemarle.org www.albemarle.org From: John Anderson Sent: Thursday, January 31, 2019 12:29 PM To: Ernest Beasley <ebeaslev@hvdrogeoenvironmental.com> Cc: Patricia Saternye <psaternve@albemarle.org> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes (Paty, please advise —thanks ) Thanks for your email, Mr. Beasley. Please submit a subdivision application (with fee) with print copy of Tier III report to get into review queues. Since this is a subdivision application, I rely on Paty for guidance. It appears a 548 fee is required with Application (image, below: pg. 3 /Application) Groundwater Review Fees J Tier 2 Groundwater Review = $355 (Required for all plats proposing lots less than 21 acre! J 'tier 3 Groundwater Review = $548 (Required for all plats proposing lots where at least 3 1 acres ur less) J 'I'icr 4 (:ruun(Iw ater Review = $1,183 Link to Application: http://www.albemarle.org/upload/itnagestforrns_center/departments/Commim4 Development/forms/applications/Subdiv ision Plat & Checklist.odf I look forward to receiving a print copy of the Tier 3 report, once submitted with Application. Thanks again -best, J. Anderson 434.296-5832 -x3069 From: Ernest Beasley <ebeaslev@hydrogeoenvironmental.com> Sent: Thursday, January 31, 2019 12:08 PM To: John Anderson <ianderson2@albemarle.org> Cc: Luke Kitelinger <Kitelingerl@yahoo.com>; Bryan Chambers<chamberslandsurveying@vahoo.com>; Kathryn Bryant <Kathryn@hydrogeoenvironmental.com>;1P Ligush<Ipligush@hydrogeoenvironmental.com> Subject: Tier 3 Groundwater Assessment for Bella Signature Homes 55 Mr. Anderson, Please see the attached Tier 3 Groundwater Assessment HydroGeo has completed on behalf of Bella Signature Homes, LLC for Albemarle Parcel #45-59M. Don't hesitate to reach out to me with any questions or comments. Many thanks, Bubba Beasley, MS, CPG Geologist c: (404) 219-6676 www.HvdroGeoEnvironmental.com 56 Patricia "Paty" Saternye From: John Anderson Sent: Thursday, January 31, 2019 12:53 PM To: Patricia Saternye Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes thanks From: Patricia Saternye Sent: Thursday, January 31, 2019 12:52 PM To: John Anderson <janderson2@albemarle.org> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes John, I would have to look back at the comments, but if the preliminary is approved it might not be necessary to review the Tier III until the final plat is submitted. I'll try to look at that later today or tomorrow morning. Thanks, Paty Saternye Senior Planner Community Development cP*I Albemarle County 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternye@albemarle.ore www.albemarle.ora From: John Anderson Sent: Thursday, January 31, 2019 12:44 PM To: Patricia Saternye <psaternye@albemarle.ore> Cc: Ernest Beasley<ebeaslev@hvdroaeoenvironmental.com> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes Paty, No, a single fee is sufficient. I will review the digital Tier III report as soon as possible, and have added a task under preliminary subdivision plat —thanks, Paty. Mr. Beasley, 57 The report is logged /in my review queue. I will review as soon as possible and withdraw request for an application related to GW assessment —thanks for sending. -best, J. Anderson 434.296-5832 -x3069 From: Patricia Saternye Sent: Thursday, January 31, 2019 12:36 PM To: John Anderson <janderson2@albemarle.ore> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes John, It appears on County View that the Fee for the Tier III Groundwater Study, for the approved SUB2018-177 Properties of Bella Signature Homes PRELIMINARY Plat, has been previously paid. Unless there is a new/different fee at the Final Plat stage, on top of the one at the Preliminary, he may not owe it. I'm not sure if there is a second fee, but I don't think there is... maybe we should ask Matt. I have not received the final plat submission yet... Thanks, Paty Saternye Senior Planner Community Development Albemarle County 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternve@albemarle.ore www.albemarle.or� From: John Anderson Sent: Thursday, January 31, 2019 12:29 PM To: Ernest Beasley<ebeasley@hydroeeoenvironmental.com> Cc: Patricia Saternye <psaternve@albemarle.org> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes (Paty, please advise —thanks ) Thanks for your email, Mr. Beasley. Please submit a subdivision application (with fee) with print copy of Tier III report to get into review queues. Since this is a subdivision application, I rely on Paty for guidance. It appears a 548 fee is required with Application (image, below: pg. 3 /Application) 58 Groundwater Review Fees J Tier 2 Groundwater Review = $355 (Required for all plats proposing lots less than 21 acre! J Tier 3 Groundwater Review = $548 (Required for all plats proposing; lots whereat least 3 1 acres or less) J Tier 4 Groundwater Review = $1,183 Link to Application: http://www.albemarle.or Lupload/itnaeestfonns_center/departments/Community Development/forms/applications/Subdiv ision Plat & Checklist.odf I look forward to receiving a print copy of the Tier 3 report, once submitted with Application. Thanks again -best, I Anderson 434.296-5832 -x3069 From: Ernest Beasley<ebeaslev@hvdroaeoenvironmental.com> Sent: Thursday, January 31, 2019 12:08 PM To: John Anderson <landerson2@albemarle.org> Cc: Luke Kitelinger <Kitelingerl@vahoo.com>; Bryan Chambers<chamberslandsurveying@yahoo.com>; Kathryn Bryant <Kathryn@hydroseoenvironmental.com>;1P Ligush<Iplieush@hvdroaeoenvironmental.com> Subject: Tier 3 Groundwater Assessment for Bella Signature Homes Mr. Anderson, Please see the attached Tier 3 Groundwater Assessment HydroGeo has completed on behalf of Bella Signature Homes, LLC for Albemarle Parcel #45-59M. Don't hesitate to reach out to me with any questions or comments. Many thanks, Bubba Beasley, MS, CPG Geologist c: (404) 219-6676 www.HvdroGeoEnvironmental.com 59 Patricia "Paty" Saternye From: Patricia Saternye Sent: Thursday, January 31, 2019 12:52 PM To: John Anderson Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes John, I would have to look back at the comments, but if the preliminary is approved it might not be necessary to review the Tier III until the final plat is submitted. I'll try to look at that later today or tomorrow morning. Thanks, Paty Saternye Senior Planner Community Development `��R41ir�4; u i R' Albemarle County 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternve@albemarle.ore www.albemarle.ors From: John Anderson Sent: Thursday, January 31, 2019 12:44 PM To: Patricia Saternye <psaternye@albemarle.org> Cc: Ernest Beasley <ebeasley@hydrogeoenvironmental.com> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes Paty, No, a single fee is sufficient. I will review the digital Tier III report as soon as possible, and have added a task under preliminary subdivision plat —thanks, Paty. Mr. Beasley, The report is logged /in my review queue. I will review as soon as possible and withdraw request for an application related to GW assessment —thanks for sending. -best, J. Anderson 434.296-5832 -x3069 From: Patricia Saternye Sent: Thursday, January 31, 2019 12:36 PM 60 To: John Anderson <landerson2@albemarle.ora> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes John, It appears on County View that the Fee for the Tier III Groundwater Study, for the approved SUB2018-177 Properties of Bella Signature Homes PRELIMINARY Plat, has been previously paid. Unless there is a new/different fee at the Final Plat stage, on top of the one at the Preliminary, he may not owe it. I'm not sure if there is a second fee, but I don't think there is... maybe we should ask Matt. I have not received the final plat submission yet... Thanks, Paty Saternye Senior Planner Community Development Albemarle County 401 McIntire Road Charlottesville, VA 22902 434-296-5832 ext.3250 psaternve@albemarle.ore www.albemarle.org From: John Anderson Sent: Thursday, January 31, 2019 12:29 PM To: Ernest Beasley<ebeaslev@hydroaeoenvironmental.com> Cc: Patricia Saternye <psaternve@albemarle.org> Subject: RE: Tier 3 Groundwater Assessment for Bella Signature Homes (Paty, please advise —thanks ) Thanks for your email, Mr. Beasley. Please submit a subdivision application (with fee) with print copy of Tier III report to get into review queues. Since this is a subdivision application, I rely on Paty for guidance. It appears a 548 fee is required with Application (image, below: pg. 3 /Application) Groundwater Review Fees ❑ Tier 2 Groundwater Review = $355 (Required for all plats proposing lots less than 21 acre! ❑ Tier 3 Groundwater Review = $548 (Required for all plats proposing lots whereat least 3 1 acres or less) ❑ Tier 4 Groundwater Review = $1,183 61