Loading...
HomeMy WebLinkAboutSDP200600093 Plan - Approved 2006-11-01TH r SCOTT R. COLLINS� No. 35791 MINOR SITE PLAN AMENDMENT GE'1V-EjT,4L NOTES'' 1. ALL MATERIALS AND CONSTRUCTION WITHIN THE PUBLIC RIGHT OF WAY SHALL BE IN ACCORDANCE WITH CURRENT VIRGINIA DEPARTMENT OF TRANSPORTATION'S SPECIFICATIONS AND STANDARDS 2. LAND USE PERMITS (CE-7P) MUST BE OBTAINED FROM THE VIRGINIA DEPARTMENT OF TRANSPORTATION PRIOR TO BEGINNING ANY CONSTRUCTION WITHIN THE EXISTING STATE MAINTAINED RIGHT OF WAY (INCLUDING ACCESS). J. VDOT IS TO RECEIVE WRITTEN NOTIFICATION 48 HOURS PRIOR TO COMMENCING WITH INITIAL CONSTRUCTION ACTI VI TIES. 4. PRIOR TO ANY CONSTRUCTION, THE CONTRACTOR SHALL CONSULT THE ENGINEER AND VERIFY THE APPROVAL OF THE PLANS BY ALL FEDERAL, STATE AND LOCAL AGENCIES. 5. PRELIMINARY DESIGN OF THE PAVEMENT STRUCTURE FOR ALL SUBDIVISION STREETS SHALL. BE IN ACCORDANCE WITH THE CURRENT EDI TION OF THE PA VEMENT DESIGN GUIDE FOR SUBDI VISION AND SECONDARY ROADS IN VIRGINIA. THE COMPLETED DESIGN WORKSHEET APPENDIX IV SHALL BE INCLUDED WITH THE INITIAL PLAN SUBMITTED FOR EACH PROPOSED PAVEMENT SECTION UTILIZING THE PREDICTED SOIL SUPPORT VALUE SHOWN IN APPENDIX I OF THE PAVEMENT DESIGN GUIDE. 6. THE CONTRACTOR SHALL VERIFY THE ELEVATIONS OF ALL POINTS OF CONNECTION OR PROPOSED WORK TO EXISTING CURBS, SANITARY LINES, WATERLINES, ETC. , PRIOR TO CONSTRUCTION. 7. UPON DISCOVERY OF SOILS THAT ARE UNSUITABLE FOR FOUNDATIONS, SUBGRADES, OR OTHER ROADWAY CONSTRUCTION PURPOSES, THE CONTRACTOR SHALL IMMEDIATELY CONTACT A GEOTECHNICAL ENGINEER AND VDOT. THESE AREAS SHALL BE EXCAVATED BELOW PLAN GRADE AS DIRECTED BY THE GEOTECHNICAL ENGINEER, BACKFILLED WITH SUITABLE MATERIAL AND COMPACTED IN ACCORDANCE WITH CURRENT VDOT SPECIFICATIONS. 8. ALL STORM SEWER DESIGN AND CONSTRUCTION TO BE IN ACCORDANCE WITH VDOT I AND I LD-94 (D) 121.13. 9. ALL STORM SEWER PIPE SHALL BE REINFORCED TONGUE AND GROVE CONCRETE PIPE IN ACCORDANCE WITH ASTM-C-76. PIPE WITHIN THE RIGHT OF WAY SHALL BE MINIMUM CLASS III OR GREATER IN ACCORDANCE WITH CURRENT VDOT STANDARDS AND SPECIFICATIONS 10. IF PRE -CAST UNITS ARE TO BE USED, VDOT SHALL BE NOTIFIED AND THE MANUFACTURER SHALL SUBMIT DRAWING DETAILS FOR REVIEW. CERTIFICATION AND VDOT STAMP WILL BE REQUIRED ON ALL UNITS 11. ALL CONCRETE SHALL BE A3-AE (AIR ENTRAINED 3, 000 PSI). 12. ALL ENTRANCES ARE TO BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH CURRENT VDOT STANDARDS RESIDENTIAL LOT ACCESS SHALL BE PROVIDED PER THE FOLLOWING CRITERIA: • ALL DRIVEWAY ENTRANCE CULVERTS ARE TO BE 15" DIAMETER x 20' LONG PIPE AND SHALL CONFORM TO PE-1 PRIVATE ENTRANCE STANDARDS UNLESS OTHERWISE DIRECTED BY THE RESIDENT ENGINEER. NO ENTRANCE CULVERTS ARE TO BE INSTALLED WITHIN FIVE (5) FEET OF PROPERTY CORNER. • VDOT STANDARD CG-9D ENTRANCES SHALL BE INSTALLED IN CURB AND GUTTER NEIGHBORHOODS THE SAW CUTTING REMOVAL OF THE STANDING CURB IS UNACCEPTABLE WHEN INSTALLING AN ENTRANCE ON EXISTING CURB AND GUTTER. CONTACT VDOT FOR INSPECTION 48 HOURS PRIOR TO ENTRANCE INSTALLATION. 13. THE DEVELOPER IS RESPONSIBLE FOR FURNISHING AND INSTALLING STOP SIGNS AT STREET INTERSECTIONS. 14. DESIGN CHANGES, SPECIFIED MATERIALS CHANGES AND/OR FIELD CHANGES FROM THE APPROVED PLANS NEED TO BE RESUBMITTED TO VDOT PRIOR TO PROCEEDING WITH THE WORK. A LETTER OF EXPLANATION SHALL ACCOMPANY THE REVISED PLANS AND/OR THE DRAINAGE CALCULATIONS, WHICH MUST BE SUBMITTED, TO VDOT FOR REVIEW AND APPROVAL BY THE RESIDENT ENGINEER. 15. CONTRACTOR SHALL VERIFY LOCATION AND ELEVATION OF ALL UNDERGROUND UTILITIES SHOWN ON PLANS IN AREAS OF CONSTRUCTION PRIOR TO STARTING WORK. CONTACT ENGINEER IMMEDIATELY IF LOCATION OR ELEVATION IS DIFFERENT FROM THAT SHOWN ON PLAN. IF THERE APPEARS TO BE A CONFLICT, AND/OR UPON DISCOVERY OF TINY UTILITY NOT SHOWN ON THIS PLAN, CALL A4155 U ;'LITY OF CENTRAL VIRGINIA AT 1-800-5.52-7001. THE DEVELOPER SHALL BI:', RESPONSIBLE FOR THE RELOCATION OF ANY UTILITY WITHIN EXISTING AND/OR PROPOSED RIGHT OF WAY REQUIRED BY THE DEVELOPMENT. 16. ALL STREETLIGHTS SHALL BE LOCATED A MINIMUM OF 9.5' FROM THE EDGE OF PAVEMENT ON CURB AND GUTTER STREETS AND/OR LOCATED A MINIMUM OF 5.5' BEHIND THE DITCH LINE ON OPEN DITCH STREETS. 17. CASING SLEEVES SHALL BE PLACED AT ALL ROAD CROSSINGS FOR GAS, POWER, TELEPHONE AND CABLE TV SERVICE TRUNK LINES. 18. THE INSTALLATION OF SEWER, WATER, AND GAS MAINS (INCLUDING SERVICE LATERALS AND SLEEVES) SHALL BE COMPLETED PRIOR TO THE PLACEMENT OF AGGREGATE BASE COURSE. 19. GENERALLY, PAVED ROADSIDE DITCHES ARE TO BE SPECIFIED WHEN VELOCITIES EXCEED CURRENT VDOT DESIGN CRITERIA OR WHEN DITCH SLOPES ARE LESS THAN 0.759 WHERE DITCH SLOPES EXCEED 5.07o, THE DEVELOPER MAY CHOOSE TO IMPLEMENT EROSION AND SEDIMENT CONTROL MEASURES IN AN ATTEMPT TO ACHIEVE CHANNEL STABILIZATION WHILE ACKNOWLEDGING THAT ADDITIONAL PAVED DITCH LININGS MA Y BE REQUIRED PRIOR TO ACCEPTANCE OF THE ROADS INTO THE SECONDARY SYSTEM OF STA TE HIGHWA Y5 PA VED ROADSIDE DITCHES SHALL CONFORM TO VDOT PG-2A STANDARDS AND SPECIFICATIONS 20. VDOT & ALBEMARLE COUNTY APPROVAL OF CONSTRUCTION PLANS DOES NOT PRECLUDE THE RIGHT TO REQUIRE ADDITIONAL FACILITIES AS DEEMED NECESSARY FOR ACCEPTANCE OF THE ROADS INTO THE VDOT SECONDARY ROAD SYSTEM. 21. VDOT APPROVAL OF THESE PLANS WILL EXPIRE THREE (3) YEARS FROM THE DATE OF APPROVAL. 22. VDOT SHALL HAVE PERFORMED THE REQUIRED FIELD INSPECTION (PROOF ROLL) PRIOR TO THE PLACEMENT OF AGGREGATE BASE COURSE(S). CONTACT VDOT FOR SUBGRADE INSPECTION 48 HOURS PRIOR TO SCHEDULING PLACEMENT OF AGGREGATE BASE COURSE(S). 23. A PRIME COAT SEAL BETWEEN THE AGGREGATE BASE AND BITUMINOUS CONCRETE WILL BE REQUIRED AT THE RATE OF 0.30 GALLONS PER SQUARE YARD (REC-250 PRIME COAT) PER VDOT STANDARDS AND SPECIFICATIONS 24. THE SCHEDULING OF AGGREGATE BASE INSTALLATION AND SUBSEQUENT PAVING ACTIVITIES SHALL ACCOMMODATE FORECAST WEATHER CONDITIONS PER SECTION 315 OF THE ROAD AND BRIDGE SPECIFICATIONS. 25. VDOT SHALL HAVE APPROVED THE AGGREGATE BASE COURSE(S) FOR DEPTH, TEMPLATE AND PERFORMED THE REQUIRED FIELD INSPECTION (PROOF ROLL) PRIOR TO PLACEMENT OF ANY SURFACE COURSE(S). CONTACT VDOT FOR INSPECTION FOR THE AGGREGATE BASE COURSE(S) 48 HOURS PRIOR TO APPLICATION OF THE SURFACE COURSE(S). 26. AN ACTUAL COPY OF THE COMPLETE CBR REPORT IS TO BE SUBMITTED TO VDOT IN CONJUNCTION WITH FINAL PAVEMENT DESIGNS ALL PAVEMENT DESIGN RECOMMENDATIONS SHALL BE PERFORMED IN ACCORDANCE WITH THE CURRENT EDITION OF THE PAVEMENT DESIGN GUIDE FOR SUBDIVISION AND .SECONDARY ROADS IN VIRGINIA. 2Z A GEOTECHNICAL ENGINEER IS TO ASCERTAIN CAUSE AND CERTIFY RECOMMENDED METHOD OF REPAIR FOR ALL PAVEMENT STRUCTURAL FAILURES PRIOR TO STATE ACCEPTANCE. 28. ALL VEGETA TION AND ORGANIC MATERIAL MA TERIAL IS TO BE REMOVED FROM THE RIGHT OF WA Y LIMITS PRIOR TO CONDITIONING OF THE SUBGRADE, 29. CERTIFICATION AND SOURCE OF MATERIALS ARE TO BE SUBMITTED TO VDOT FOR ALL MATERIALS AND BE IN ACCORDANCE WITH THE ROAD AND BRIDGE SPECIFICA TIONS, AND ROAD AND BRIDGE STANDARDS 30. THE DEVELOPER WILL BE RESPONSIBLE FOR THE DESIGN COSTS OF ANY TRAFFIC SIGNAL INSTALLATION AND/OR MODIFICATION UNDER AN ACCOUNT RECEIVABLE WITH VDOT. 31. THE NECESSITY AND LOCATIONS FOR ADDITIONAL VDOT STANDARD UNDERDRAINS TO BE DETERMINED AT THE TIME OF SUBGRADE INSPECTION. 32. APPROVAL OF A DETAILED CONSTRUCTION SEQUENCING/MAINTENANCE OF TRAFFIC NARRATIVE FOR THE WORK ZONE IS A PREREQUISITE FOR ISSUANCE OF A LAND USE PERMIT ALLOWING ACCESS TO AND CONSTRUCTION WITHIN VDOT MAINTAINED RIGHT OF WAY. 33. VDOT SHALL BE PROVIDED DOCUMENTATION THAT ALL IN PLACE PAVEMENTS MEET OR EXCEED THE APPROVED PAVEMENT DESIGN THICKNESS PRIOR TO STATE ACCEPTANCE. 34. GRADE LINES ON PROFILES DENOTE FINISHED GRADE OF CENTER LINE OF ROAD. 35. OWNER WILL FURNISH SURVEY CONTROL OFFSET HUBS FOR ALL ROADS AND EASEMENTS FOR ALIGNMENT AND GRADE. ROADS WILL BE STAKED ONLY ON ONE SIDE. THE CONTRACTOR SHALL INSPECT THE CONTROL STAKING AND VERIFY BEFORE CONSTRUCTION. ALL GRADE STAKES DESTROYED BY THE CONTRACTOR SHALL BE REPLACED AT HIS EXPENSE. 36. ALL APPROACH GUTTERS TO SAG INLETS SHALL MAINTAIN A MINIMUM SLOPE OF 0.004 ft./ft. 37. WHERE A TYPE "B" NOSE IS SPECIFIED ON AN INLET IN CONJUNCTION WITH ROLL FACE CURB AND GUTTER OR CG-7, THERE SHALL BE A 20' TRANSITION ON EACH SIDE OF THE INLET. REVISIONS DATE SHEET NUMBERS DATE SHEET NUMBERS 7/20/06 2 RIO DISTRICT ALBEMARLE COUNTY, VIRGINIA WHITEHALL DISTRICT �P0 G� VICINITY MAP NOT TO SCALE LAII�� iiii . 9 omwd, I i'l -6-0.4 blakol winflLiq us OWNER & DEVELOPER 8/10/06 THIS MINOR SITE PLAN AMENDMENT IS FOR: 1. REVISION TO LOCATION OF STORAGE CONTAINER ON PROPERTY SHFFT TNDFX- SHEET TITLE SHEET NO. COVERSHEET.................................................................... 1 LAYOUT PLAN 2 ............................................................................. . APPROVALS TIMMONS GROUP IS NOT RESPONSIBLE OR LIABLE FOR ANY CON ()'TRUC TION OR DAMAGES TO THIS PROJECT PRIOR TO ALL FINAL PLAN APPRO VA S. URRENT DEVELOPMENT: PLANNING AND ZONING I CURRE"IT DEVELOPMENT: ENGINEE 'ING (INCLUDES VDOT APPROVAL) ARB FIRE OFFICIAL ALBEM RLE COUNTY SERVICE AUTHORITY RGINIA DEPARTMENT OF HEALTH BUILDING OFFICIAL ZONED: Cl COMMERCIAL TAX MAP #Is: 061WO-01-OA-0020 o , ��SSIONAL Eli E H O z N Cif 0 N E > N 0 w W I- V Q LL U. 1 r wO�M W z pp Q a J fu Ln J � > U N �a V1 - d' L Q C7 11J i 't Z O X in Q V O H O Z � 0 ,4 L H V = un ~ L to w H Z w" o C7 ao o > w > m � C v O 0 r C o � w w CL Q 0 w o > U) a7 o F C C i ., DATE DRAWN BY K. KOSTELEC DESIGNED BY S. COLLINS CHECKED BY Ll S. COLLINS c SCALE c c NO SCALE r c 0 z W z �LLJ G z W Ljf E--�ct U7 0 z W J W uj i JOB NO. SHEET NO. 1 C W i W a C W E Oc a U V z C w LL I a C a a S a L C V c 0. L c z T a C .0 c fL C i c c v c a V a s 6 Q I co O 0 N D Q I J z 41 O J Q >, -1 co q) L L d- 0 -;t- .-A