HomeMy WebLinkAboutSDP200800097 Legacy Document 2008-08-08of ,a� eF
� �RGiN�P
ALBEMARLE COUNTY PLANNING
STAFF REPORT SUMMARY
Project Name: SDP 08- 97:Couch Property
Staff: Gerald Gatobu Senior Planner
( Verizon) Tier II PWSF
Planning Commission Public Hearing:
Board of Supervisors Hearing:
August 12th, 2008
N/A
Owners: Couch, Robert W JR Or Mildred A
Applicant: Cellco Partnership D /B /A Verizon
Wireless
Acreage: 3.06 Acres
Rezone from: Not applicable
(Lease Area: 2,500 square feet)
Special Use Permit for: Not applicable
TMP: Tax Map 94, Parcel 34
By -right use: RA, Rural Area, and (EC)
Location: Black Cat Road [State Route 616]
Entrance Corridor
approximately 300 feet from the intersection
of Black Cat Road [State Route 616] and
Further Lane [Private].
Magisterial District: Scottsville
Proffers /Conditions: No
Requested # of Dwelling Units /Lots: N/A
DA - RA -X
Proposal: To install a Tier II personal
Comp. Plan Designation: Rural Area in
wireless service treetop facility; the
Rural Area 2
proposed facility consists of a 100 foot
tall monopole
Character of Property: Residential farmland
Use of Surrounding Properties: Single -
parcel with significant mature tree canopy.
family Residential
Factors Favorable:
Factors Unfavorable:
• Monopole will be (seven) 7' feet above
• The application plan proposes the
the reference tree which mitigates the
removal of 5 existing trees to allow
visual impacts of the tower.
for the monopole and equipment
shelter.
RECOMMENDATION: Staff recommends approval of this personal wireless service facility.
Based on findings presented in the staff report, staff recommends approval at 7 feet above
the reference tree.
STAFF CONTACT:
PLANNING COMMISSION:
AGENDA TITLE:
PROPERTY OWNER:
APPLICANT:
Gerald Gatobu
August 12, 2008
SDP 08 -0097: Couch Property ( Verizon) Tier II PWSF
Couch, Robert W JR or Mildred A
Cellco Partnership D /B /A Verizon Wireless
PROPOSAL:
This is a proposal to install a Tier II personal wireless service treetop facility (Attachment A).
The proposed facility consists of a 100 -foot tall steel monopole, painted with Sherwin Williams
Java Brown, which is a matte enamel color that has been previously approved as an appropriate
color for Tier II facilities at other sites in Albemarle County. The top elevation of the monopole
is 545 feet, measured above mean sea level (AMSL). The proposed monopole will be 7 feet
higher than the identified reference tree. The monopole will be equipped with three (3) flush -
mounted antennas, a two (2) foot long lightning rod, and coaxial cables that will be run within
the monopole's interior. Supporting ground equipment will be contained within a prefabricated
equipment shelter measuring 12'x 30'x 10.92 (W x L x H) at the base of the tower.
The lease area for the proposed facility is located on property described as Tax Map 94, Parcel
34, which is approximately 3.06 acres and is zoned RA, Rural Area (Attachment B). The site is
located on Black Cat Road [State Route 616] approximately 300 feet from the intersection of
Black Cat Road [State Route 616] and Further Lane [Private]. This application has been
submitted in accordance with Section 10.2.1(22) of the Zoning Ordinance, which allows for Tier
II wireless facilities by right in the Rural Areas.
COMPREHENSIVE PLAN:
The Comprehensive Plan designates this property as Rural Area in Rural Area 2.
CHARACTER OF THE AREA:
The proposed site is on a 3.06 acre lot with a single family dwelling located approximately 300
feet from the intersection of Black Cat Road [State Route 616] and Further Lane [Private]. The
lease area is wooded with access provided off an existing driveway that will be extended to the
east/rear of the property to the tower site. The property is surrounded by single - family residential
homes. Interstate 64 is to the north and State Route 250 to the south of the property.
PLANNING AND ZONING HISTORY:
CP 1976 -023: 06/14/76 Violation prior to Mr. Couch Owning the property. Abated
VIO 1976 -027: 08/04/1976 Violation abated by violation 2003 -007.
CP 1976 -034: 0728/76 Violation abated by violation 2003 -007.
VIO 2003 -007: Violation for a dumpsite abated October 22nd 2004. New owner, Mr. Couch,
bought the property and cleaned it up per contract agreement.
2
STAFF COMMENT:
Section 3.1 provides the following definitions that are relevant to this proposal:
Tier II personal wireless service facility: A personal wireless service facility that is a treetop
facility not located within an avoidance area.
Treetop facility: A personal wireless service facility consisting of a self - supporting monopole
having a single shaft of wood, metal or concrete no more than ten (10) feet taller than the crown
of the tallest tree within twenty -five (25) feet of the monopole, measured above sea level (ASL),
and includes associated antennas, mounting structures, an equipment cabinet and other essential
personal wireless service equipment.
Avoidance area: An area having significant resources where the siting of personal wireless
service facilities could result in adverse impacts as follows: (i) any ridge area where a personal
wireless service facility would be skylighted; (ii) a parcel within an agricultural and forestal
district; (iii) a parcel within a historic district; (iv) any location in which the proposed personal
wireless service facility and three (3) or more existing or approved personal wireless service
facilities would be within an area comprised of a circle centered anywhere on the ground having
a radius of two hundred (200) feet; or (v) any location within two hundred (200) feet of any state
scenic highway or by -way.
Section 5.1.40(d), "Tier II facilities" states:
"Each Tier II facility may be established upon commission approval of an application satisfying
the requirements of subsection 5.1.40(a) and demonstrating that the facility will be installed and
operated in compliance with all applicable provisions of this chapter, criteria (1) through (8)
below, and satisfying all conditions of the architectural review board. The commission shall act
on each application within the time periods established in section 32.4.2.6. The commission
shall approve each application, without conditions, once it determines that all of these
requirements have been satisfied. If the commission denies an application, it shall identify which
requirements were not satisfied and inform the applicant what needs to be done to satisfy each
requirement. "
The applicant has submitted an application that satisfies the requirements set forth in Section
5.1.40(a) and has performed a balloon test at the location of the proposed facility (Attachment
C)..
Section 5.1.40(b)(2): Exemption from regulations otherwise applicable: the agent may authorize
a facility to be located closer in distance than the height of the tower or other mounting structure
to any lot line if the applicant obtains an easement or other recordable document showing
agreement between the lot owners, acceptable to the county attorney addressing development on
the part of the abutting parcel sharing the common lot line that is within the facility's fall zone.
The applicant will have to obtain a fall zone easement (before a building permit can be issued) or
other recordable document showing agreement between the lot owners, acceptable to the county
attorney addressing development on the part of the abutting parcel sharing the common lot line
that is within the facility's fall zone
3
Section 5.1.40(d)(1): The facility shall comply with subsection 5.1.40(b) and subsection
5.1.40(c)(2) through (9).
Staff has determined that the proposed facility's location complies with all other exemptions of
Section 5.1.40(b) and the proposed equipment meets all relevant design, mounting and size
criteria that are set forth in Section 5.1.40(c)(2) and (3). The remainder of subsection (c)
provides requirements that are subject to enforcement if the facility is approved.
Section 5.1.40(d)(2): The site shall provide adequate opportunities for screening and the facility
shall be sited to minimize its visibility from adjacent parcels and streets, regardless of their
distance from the facility. If the facility would be visible from a state scenic river or a national
park or national forest, regardless of whether the site is adjacent thereto, the facility also shall
be sited to minimize its visibility from such river, park or forest. If the facility would be located
on lands subject to a conservation easement or an open space easement, the facility shall be
sited to so that it is not visible from any resources specifically identified for protection in the
deed of easement.
The proposed facility includes a monopole that would have a height of approximately 545 feet
above mean sea level (AMSL). The height of the reference tree is 535 feet above mean sea level
(AMSL) and its dripline is located within 10 feet of the proposed monopole. A balloon test was
conducted on June 26th, 2008. The balloon was visible from the neighbor's property across State
Route 616 at 10 feet above the top of the reference tree. As a comparison, the balloon was
lowered so that it was only 7' above the reference tree, 542 feet AMSL. The balloon was still
visible from the neighboring property and the trees did not provide a backdrop for the balloon, so
when it was visible, it was sky -lit. There was a material difference in the visibility of the balloon
when the height was reduced from 7' to 10' above the canopy of the reference tree. At 7'feet
above the reference tree, the sky -lit appearance of the pole was less pronounced. The ground
equipment is not expected to be visible due to the dense vegetation and existing single family
residence located between the state road and the facility.
Based on the information above, it is staff's opinion that the proposed facility will be minimally
visible from adjacent parcels and streets at seven feet (7) above the tallest tree.
Section 5.1.40(d)(3): The facility shall not adversely impact resources identified in the county's
open space plan.
Staff's analysis of this request addresses the concern for the possible loss of aesthetic or historic
resources. The proposed lease area is not delineated as a significant resource on the Open Space
Plan Map. However, the installation of this tower within the 2,500 square foot lease area will
require the removal of five trees. None of the trees to be removed significantly contribute to the
screening of the facility. An arborist report certifying that the proposed removal of 5 existing
trees, the proposed fill grades, and digging required to install the concrete piers and generator
pad will not be detrimental to the health of any trees designated to remain must be submitted
before the final site plan is approved. A tree conservation plan with measures proposed that
would limit impacts of this proposal on all existing trees designated to remain is also required. ,
FEW
The County's wireless service facilities policy encourages facilities with limited visibility,
facilities with adequate wooded backdrop, and facilities that do not adversely impact Avoidance
Areas (including Entrance Corridors and historic resources). The proposed pole is minimally
visible when traveling by car on State Route 616. The tower will be mostly visible to the
neighbor across the street, but at 7' (seven) feet above the reference tree, the sky -lit appearance
of the pole should be significantly mitigated. The monopole will not be visible from the State
Route 250 entrance corridor and Interstate 64 entrance corridor. Staff believes the visibility of
the monopole will not adversely impact open space plan resources and fully complies with the
county's wireless service facilities policy.
Section 5.1.40(d)(4): The facility shall not be located so that it and three (3) or more existing or
approved personal wireless service facilities would be within an area comprised of a circle
centered anywhere on the ground having a radius of two hundred (200) feet.
There is no other existing personal wireless service facility located within an area comprised of a
circle centered anywhere on the ground having a radius of two hundred (200) feet.
Section 5.1.40(d)(5): The maximum base diameter of the monopole shall be thirty (30) inches
and the maximum diameter at the top of the monopole shall be eighteen (18) inches.
Notes on the construction plans for this facility propose a monopole that will have a maximum
base dimension of 30 inches and a maximum dimension of 18 inches at the top. These
dimensions comply with the maximum width requirements for treetop monopoles serving Tier II
facilities.
Section 5.1.40(d)(6): The top of the monopole, measured in elevation above mean sea level,
shall not exceed the height approved by the commission. The approved height shall not be more
than seven (7) feet taller than the tallest tree within twenty-five (25) feet of the monopole, and
shall include any base, foundation or grading that raises the pole above the pre- existing natural
ground elevation; provided that the height approved by the commission may be up to ten (10)
feet taller than the tallest tree if the owner of the facility demonstrates to the satisfaction of the
commission that there is not a material difference in the visibility of the monopole at the
proposed height, rather than at a height seven (7) feet taller than the tallest tree; and there is not
a material difference in adverse impacts to resources identified in the county's open space plan
caused by the monopole at the proposed height, rather than at a height seven (7) feet taller than
the tallest tree. The applicant may appeal the commissioner's denial of a modification to the
board of supervisors as provided in subsection 5.1.40(d)(12).
As mentioned previously in this report, the applicant has proposed a 100 foot tall monopole, but
staff recommends the monopole be installed at a height of 97 feet (seven feet taller than the
tallest tree as opposed to 10'feet taller than the tallest tree) or 542 feet AMSL. The height of
the reference tree is 90 feet tall or 535 feet above mean sea level (AMSL). The monopole will be
(7) feet taller than the tallest tree within twenty -five (25) feet. The height approved by the
Planning Commission may be up to ten (10) feet taller than the tallest tree if the owner of the
facility demonstrates to the satisfaction of the commission that there is not a material difference
in the visibility of the monopole at the proposed 10 feet above the tallest tree. Based on the
balloon test mentioned above, staff determined that there would be a material difference in
the visibility of the monopole at a height of (10) feet, rather than at a height of 7 feet taller
than the tallest tree.
5
Section 5.1.40(d)(7): Each wood monopole shall be a dark brown natural wood color; each
metal or concrete monopole shall be painted a brown wood color to blend into the surrounding
trees. The antennas, supporting brackets, and all other equipment attached to the monopole
shall be a color that closely matches that of the monopole. The ground equipment, the ground
equipment cabinet, and the concrete pad shall also be a color that closely matches that of the
monopole, provided that the ground equipment and the concrete pad need not be of such a color
if they are enclosed within or behind an approved structure, fagade or fencing that: (i) is a color
that closely matches that of the monopole; (ii) is consistent with the character of the area; and
(iii) makes the ground equipment and concrete pad invisible at any time of year from any other
parcel or a public or private street.
The applicant is proposing the installation of a facility with a metal monopole. The proposed
color for the tower and screening fence is a brown paint that has been previously used and
approved in Albemarle County. A note on the construction plans identifies the proposed brown
color of the antennae and ground equipment for this facility as Sherwin Williams Matte "Java
Brown" #6090.
Section 5.1.40(d)(8): Each wood monopole shall be constructed so that all cables, wiring and
similar attachments that run vertically from the ground equipment to the antennas are placed on
the pole to face the interior of the property and away from public view, as determined by the
agent. Metal monopoles shall be constructed so that vertical cables, wiring and similar
attachments are contained within the monopole's structure.
Schematic drawings provided in the construction plan packet indicate that the vertical wires
extending from the ground equipment to the antennas shall be contained within the monopole
structure.
Section 704(a)(7)(b)(I)(II) of The Telecommunications Act of 1996:
This application is subject to the Telecommunications Act of 1996, which provides in part that
the regulation of the placement, construction, and modification of personal wireless service
facilities by any State or local government or instrumentality thereof (I) shall not unreasonably
discriminate among providers of functionally equivalent services; (II) shall not prohibit or have
the effect of prohibiting the provision of personal wireless services. 47 U.S. C.
The Telecommunications Act addresses concerns for environmental effects with the following
language, "No state or local government or instrumentality thereof may regulate the placement,
construction, and modification of personal wireless service facilities on the basis of the
environmental effects of radio frequency emissions to the extent that such facilities comply with
the Commissions' regulations concerning such emissions." In order to operate the proposed
facility, the applicant is required to meet the FCC guidelines for radio frequency emissions.
These requirements will adequately protect the public health and safety.
It is staff's opinion that the denial of this application would not have the effect of prohibiting the
provision of personal wireless communication services.
on
SUMMARY:
Staff has identified factors which are favorable and unfavorable to this proposal:
Factors favorable to this request include:
• Monopole will be (seven) 7' feet above the reference tree which mitigates the visual
impacts of the tower.
Factors unfavorable to this request include:
• The application plan proposes the removal of 5 existing trees: 5 nine inch (9 ") Ash trees
will be removed to allow for the monopole and equipment shelter.
RECOMMENDATION: Staff recommends approval of this personal wireless service facility.
Based on findings presented in the staff report, staff recommends approval at 7 feet above the
reference tree.
In order to comply with Section 5.1.40(d) of the Zoning Ordinance, the Planning Commission is
required to provide the applicant with a statement regarding the basis for denial and all items that
will have to be addressed to satisfy each requirement.
ATTACHMENTS:
A. Site Plan
B. Vicinity Map
C. Balloon photos at proposed location
D. ARB letter determining tower location is not in the entrance corridor
7
ZONING ADMINISTRATOR
PLANNING COMMISSION AGENT DATE ( \ ^• C Am
BOARD OF SUPERVISORS CHAIRMAN /�Pi /P■ 1 1
PATE
ve—�rlz.o.n � w•
DATE SITE NAME: BOYD TAVERN ( COUCH PROPERTY)
1641 BLACK CAT ROAD
KESWICK, VA 22947
INSTALLATION OF A 1 00' A.G.L. MONOPOLE, ANTENNAS AND ASSOCIATED EQUIPMENT
VICINITY MAP (N. T. S)
PROJECT DESCRIPTION:
CONSTRUCTION OF A PERSONAL COMMUNICATION SYSTEM (PCS)
CONSISTING OF A PROPOSED MONOPOLE, PROPOSED ANTENNAS
& APPURTENENCES, & PROPOSED EQUIPMENT SHELTER WITHIN A
PROPOSED UNMANNED GRAVELED COMPOUND WITH SECURITY
FENCING. NO WATER OR SEWER IS REQUIRED.
CODE COMPLIANCE:
ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN
ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING
CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES.
NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK
NOT CONFORMING TO THE LATEST EDITIONS OF THE FOLLOWING:
1. VA BUILDING CODE 5. ANSI /TIA /EIA -222 -F
2. UNIFORM BUILDING CODE 6. UNIFORM PLUMBING CODE
3. BUILDING OFFICIALS AND CODE 7. NATIONAL ELECTRIC CODE
ADMINISTRATORS (BOCA) 8. LOCAL BUILDING CODE
4. UNIFORM MECHANICAL CODE 9. CITY /COUNTY ORDINANCES
n f i n i
e n g i n e e r i n
2255 SEWELL MILL ROAD
SUITE 130
MARIETTA, GA 30062
OFFICE #: (678) 444 -4463
FAX #: (678) 444 -4472
JS4 \ BOYD TAVERN
4a
E eon .,SIP
o
e 7:.
LOCATION MAP (N. T. S.)
g�9
LATITUDE: 37' 59' 28.73" N
LONGITUDE: 78° 20' 14.14" W
ELEVATION: ±445.48' AMSL
KESWICK, VIRGINIA
ALBEMARLE COUNTY
PROJECT SUMMARY
LAND OWNER:
POWER COMPANY:
BOB & MILDRED COUCH
CONTACT PHONE #:
4886 RICHMOND ROAD
TELCO COMPANY:
KESWICK, VA 22947
CONTACT PHONE #:
CONTACT: BOB & MILDRED
COUCH
434 -984 -0820 (W) OR 434
-296 -3713 (H)
APPLICANT:
S1
VERIZON WIRELESS
-
1831 RADY COURT
S2
RICHMOND, VA 23222
-
CONTACT: STEPHEN WALLER
Z1
434 - 825 -0617
C 107/10/08
PROJECT DATA:
TAX MAP - PARCEL ID:
TMP 94 -34
ZONING CLASSIFICATION:
RA
ZONING JURISDICTION:
ALBEMARLE COUNTY
PARENT PARCEL:
3.060
AREA OF DISTURBANCE:
±7,400 SQ FT
% OF PARCEL DEVELOPED:
2%
LEASE AREA:
±.06 ACRES
EXISTING IMPERVIOUS AREA: 0 SQ FT
PROPOSED IMPERVIOUS AREA: ±5,200 SQ FT
POWER TELCO UTILITIES
POWER COMPANY:
CENTRAL VIRGINIA ELECTRICAL COOP
CONTACT PHONE #:
(800) 367 -2832
TELCO COMPANY:
EMBARQ
CONTACT PHONE #:
(866) 380 -9990
LTHOF
Y
`.ER J. WARREN
03 ?631
-,--DRAWING
INDEX
B
02/29/08
DRWG. #
TITLE
REV.#
DATE
T1
COVER SHEET
B
02/29/08
S1
SURVEY
-
11/06/07
S2
SURVEY
-
11/06/07
Z1
SITE PLAN
C 107/10/08
STREET. TURN RIGHT ONTO MECHANICSVILLE TURNPIKE /US -360 WEST. MERGE ONTO 1 -64
WEST TOWARD 1 -95. MERGE ONTO 1 -64 WEST VIA EXIT 79 TOWARD POWHITE
PARKWAY /CHARLOTTESVILLE. TAKE THE VA -616 EXIT (EXIT 129) TOWARD KESWICK /BOYD
i TAVERN ROAD. TURN LEFT ONTO BLACK CAT ROAD. 1541 WILL BE ON YOUR LEFT JUST
t -o$
srL%N,4Lti��t .X�`
�o-
Z1A
AREA MAP
B
02/29/08
Z2
LEASE AREA SITE
PLAN & LAYOUT
C
07/10/08
Z3
TOWER ELEVATION &
DETAILS
B
02/29/08
DIRECTIONS:
FROM RICHMOND OFFICE, TURN LEFT ONTO RADY STREET. TURN LEFT ONTO MAGNOLIA
Z4
GRADING, EROSION, &
SEDIMENT CONTROL PLAN
0
02/29/08
Z5
GRADING, EROSION, &
SEDIMENT CONTROL NOTES
0
02/29/08
STREET. TURN RIGHT ONTO MECHANICSVILLE TURNPIKE /US -360 WEST. MERGE ONTO 1 -64
WEST TOWARD 1 -95. MERGE ONTO 1 -64 WEST VIA EXIT 79 TOWARD POWHITE
PARKWAY /CHARLOTTESVILLE. TAKE THE VA -616 EXIT (EXIT 129) TOWARD KESWICK /BOYD
i TAVERN ROAD. TURN LEFT ONTO BLACK CAT ROAD. 1541 WILL BE ON YOUR LEFT JUST
Z6
WAVEGUIDE BRIDGE DETAILS
B
02/29/08
Z7
SHELTER ELEVATIONS
B
02/29/08
PAST FURTHER LANE.
Z8
FENCE DETAILS
B
02/29/08
EMERGENCY / FIRE
ALBERMARLE COUNTY
434 - 972 -4001
MISS UTILITY
OF VIRGINIA
CALL TOLL FREE
1- 800 - 552 -7001
THREE WORKING MIS BEFORE YOU DIG
Attachment A
ONE
0
J
�O
�QZ
20 "POPLAR
TOP ELEV. = 532'
O0.
28" OAK
TOP ELEV. = 535'
Q
OQ
CQ
V
INSET
\ SCALE 1" --50'
5ek
a
�o
6�
51L, P
S 81 °07'05 E
co L
V
N 88 °37'05" W -
TAX ID #94 -29A3
PROPERTY OF
BEASLEY
DEED BOOK 1271, PAGE 011
LINE
BEARING
DISTANCE
L1
N 88 °46'30" W
45.11'
L2
N 60 °03'47" W
121.01'
L3
N 88 °35'40" W
34.00'
L4
N 63 035'58" W
114.69'
QOa
LEGEND
—R— —R— Adjoiner
Creek
- - - - - -Edge of Road
-
x - x - x - x - Fence
- - - -
-Overhead Utility Line
a Utility Pole
Tree (12" or Larger)
20'Access Easement
INSET
TAX ID #94 -34C
PROPERTY OF
HUDSON
DEED BOOK 1899, PAGE 189
_Z___ 100'RADIUS
NOTES,•
1. THEBOUNDARYAS SHOWN ON THIS
MAP WAS PLOTTED FROM DEEDS
2. THIS MAP DOES NOT MEET VIRGINIA STATE
STANDARDS FOR A BOUNDARYPLA T.
3 THE SOLE PURPOSE OF THIS MAP IS TO
ESTABLISHA LEASEPARCEL FORA CELLULAR
TELEPHONE INSTAL LA TION.
3. SUBJEC TPROPERTYA S SHOWN IS
ALBEMARLE COUNTY TAX /D# 94 -34.
4. SUBJECT PROPERTYAS SHOWN DOES NOT FALL
W/ THIN THE L /M /TS OF H. U. D. DESIGNA TED FL OOD
HAZARD ZONE. THIS OPINION IS BASED UPON AN
INSPECTION OF THE FL OOD INSURANCE RA TE MAPS
(COMMUNITYPANEL #51003C 0475D, ZONEX)
AND HAS NOT BEEN FIELD VERIFIED.
5. ALL OWNER AND TAX /D /NFORMA TION SHOWN
WAS OBTAINED FROM THE AL BEAM RLE COUNTY
GIS WEBSITE THIS SURVEYOR TAKES NO
RESPONSIBILITY FOR THEA CCURA C Y OF THIS
INFORMA TION.
VICINITY MAP
-- Not to Scale --
Z-892-62- BO YD TA VERN
TAX ID #94 -34
ASEPARCEL PROPERTY OF
1 COUCH
DEED BOOK 2719, PAGE 665
% "7
c
Q TAX ID #94 -29A
PROPERTY OF
GRISS/NGER
DEED BOOK 397, PAGE 400
o
1 1/ 00 00
CURVE
DELTA ANGLE
RADIUS
ARC LENGTH
CHORD LENGTH
CHORD BEARING
TANGENT
C1
05 °56'54"
2037.63'
211.54'
211.45'
N 16 °52'55" E
105.87'
C2
28 °42'43"
115.00'
57.63'
57.03'
N 74 °25'09" W
29.43'
C3
28 °31'53"
50.00'
24.90'
24.64'
N 74° 19'43" W
1231'
C4
24 °59'42"
50.00'
21.81'
21.64'
N 76 °05'49" W
11.08'
0.00'(Total)
F
C, y)
0
TAX /D #94 -33
PROPERTY OF
LEWIS
DEED BOOK 3449, PAGE 644
1` J, LTH 0,,c '0 ��►
�Ar O BRIAN L. SUTPHIN U?Z
U
(LICENSE) No.
2679
.�
D -COUCH
MAP SHOWING
PROPOSED LEASE PARCEL
PROPERTY OF
COUCH
LOCATED ON
VIRGINIA SECONDARY ROUTE #616
"BLACK CAT ROAD"
ALBERMARLE COUNTY, VIRGINIA
SCALE: I"=100' DATE: 6 NOVEMBER 2007
BLUE RIDGE SURVEYING & MAPPING, INC.
864 WEST STUART DRIVE
HILLSVILLE, VIRGINIA 24343
PHONE/FAX 276.728.2022 - EMAIL: brsurvey @comcast.net
NATIONAL SURVEY SERVICES COORDINATION BY:
G E L INE Alachua, NW 104th Terrace, Suite A
JOB #1130 Alachua, FL 32615
T (�` (386) 418 -0500
PAGE 1 OF SURVEYING, 1 NC. (3WWW.GEOLINEINC.COM
LEGAL DESCRIPTIONS
LEASE PARCEL:
BEGINNING A TA 518" ROD SET, SAID POINT BEING N 87 °48'04" E
11 7.21 ' FROM A 518" ROD FOUND CORNER TO BEASLEY(DB 1271,
PAGE 011) AND GRISSINGER(DB 397, PAGE 400), THENCE
N 01 ° 13 30" E 50.00' TO A 518'ROD SET, THENCE S 88'4630" E 50.00'
TO A 518" ROD SET, THENCE S 01 -13'30- W 50.00' TO A 518" ROD
SET, THENCE N 8846'30" W 50.00' TO THE BEGINNING, AND
CONTAINING 2,500 SQUARE FEET.
20'A CCESS EA SEMENT.-
BEGINNING A TA POINT, SAID POINT BEING N 01 -13'30- E 30.22'
FROM THE POINT OF BEGINNING OF THE ABOVE DESCRIBED
PARCEL, THENCE WITH THE CENTERLINE OFA NEW 20'ACCESS
EASEMENT THE FOLLOWING SEVEN CALLS: N 88 °46'30" W45.11'
TO A POINT, THENCE WITH A CURVE TO THE RIGHT HAVING A
CHORD BEARING OF N 74'25'09- W, A CHORD DISTANCE OF
57.03, A RADIUS OF 115.00; AN ARC LENGTH OF 57.63, A
TANGENT OF 29.43, AND A DELTA ANGLE OF 28 °4243" TO A POINT,
THENCE N 60'03'4 7" W 121.01' TO A POINT, THENCE WITH A CURVE
TO THE LEFT HA VING A CHORD BEARING OF N 74'19'43" W, A
CHORD DISTANCE OF 24.64 , A RADIUS OF 50.00, AN ARC
LENGTH OF 24.90, A TANGENT OF 12.71, AND A DELTA ANGLE
OF 28 °31'53" TO A POINT, THENCE N 88 °3540" W 34.00' TO A POINT,
THENCE WITH A CURVE TO THE RIGHT HAVING A CHORD BEARING
OF N 76 °05'49" W, A CHORD DISTANCE OF 21.64, A RADIUS OF 50. 00,
AN ARC LENGTH OF 21.81, A TANGENT OF 11. 08', AND A DELTA
ANGLE OF 24'5942" TO A POINT, THENCE N 63-35'58- W 114.69' TO
THE RIGHT -OF -WA Y OF RTE# 616.
PROPOSED TOWER L OCA T /ON INFORMATION
HORIZONTAL POSITION (NAD83)
LATITUDE = 37 °59'28.73" N ±50'
LONGITUDE= 78 °20'14.14" W ±50'
VERTICAL POSITION (NAVD88)
GROUND ELEVATION AT BASE OF TOWER= 445.48' ±20'
PAGE 2OF2
Q /
,r
2
7o
'� /
r V ' �
o�
V y HUDSON, DOUGLAS D. & STERLING M. HUDSON
81'07'QJr-, E DEED BOOK 1899, PAGE 189
EXISTING UTILITY
o\I \ POLE (TYP.) G SED12' ESS
DRIVE
PROPOSED
O /�/ \ \ — EASEMENT 20
(Q \ ACCESS UTILITY; = " " - - - - -- -
cu 7 \
j EXISTINGI �� \ �\ �
HOUSE J ❑ \ \\ T BE REM
EXISTING EXISTING WOODEN
N DRIVE STORAGE SHELTER O_
V1
��^^ APPROXIMATE
tJ IN 88 °37'05" W -
411 co I I I TREE DRIPUNE
I I REFERENCE TREE
(28' OAK)
�I o ---- - - - - --
O
VQi TAX ID #94 -29A3
+ BEASLEY, CHARLES CUTLER AS GEORGIE E.
DEED BOOK 1271, PAGE 011
RESIDENTIAL
GRAPHIC SCALE
NOTES:
1. THIS SITE IS NOT LOCATED WITHIN OR ADJACENT TO A
COUNTY DESIGNATED CONSERVATION EASEMENT.
2. THIS SITE IS NOT LOCATED WITHIN ANY AREA
DESIGNATED AS AN AGRICULTURAL OR FORESTAL DISTRICT.
3. ALL UTILITY LINES TO BE RUN UNDERGROUND WITHIN
THE PROPOSED ACCESS /UTILITY EASEMENT SHOWN AND
LABELED ON PLAN. FINAL LOCATION OF UTILITIES WILL BE
DETERMINED BY THE COMPANIES PROVIDING ELECTRICAL
AND TELEPHONE SERVICES.
892.62'
PROPOSED
VERIZON 50'x50' �- -�-_
2255 SEWELL MILL ROAD
I-ESE AREA
SUITE 130
MARIETTA. GA 30062
TAX I D #94 -34
TEL., 678 444.4463
PROPERTY OF
-�
O I
COUCH, ROBERT W. JR. OR MILDRED A.
CD
ISTING TREELINE DEED BOOK 2719, PAGE 665
" 1
---------- - - - - --
O
T930.00'(Total)
_ c/) — — — — — —
100' RADIUS I
FALL ZONE
TAX ID #94 -33
LEWIS, ANNA F.
DEED BOOK 3449, PAGE 644
VACANT
TAX ID #94 -29A
GRISSINGER, GEORGE E.
DEED BOOK 397, PAGE 400
VACANT
N 1 SITE PLAN
APPROX. NORTH
v Lon wireless
1831 RADY COURT
RICHMOND, VA 23222
�infinigy�
e IT g i n e e F i n, CV(
2255 SEWELL MILL ROAD
��7
SUITE 130
MARIETTA. GA 30062
TEL., 678 444.4463
FAX: 678-44-4-4472
WWW.INFlNICY.COM
THESE DRAWINGS AND1 DR THE 1LCOYPANYING VEWICATION
AS INS"ENTS OF SEIMCE. ARE THE EXCEM PROMM
OF VEIRON WIRELESS AND THEM 115E AND PUBLICATION
SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH
DO ARE PREPARED. REUSE, REPRODUCTION OR PIBUCATO
8Y ANY YETIAD, IN WHOLE OR W PARE, 6 PAOHIBIIED
CEEWRITTEN VERZON W
TBETDTHESE `�FI S
REIM WITH VERRON WIRELESS W MIT PREAW AND
V6U4L CONGCT WRM TMFL SHALL CONSRRRE F'F1W FACE
ENOENCE OF ICIVAI OF TIESE RESTRR:II.TIS.
REVISION
HID. DESCRIPTION BY DATE
/ \ RAVED FOR REVEW DAD 11/09/07
AE-ISW FOR REVEW CJN 02 /M /O8
C RE- ISM FOR RD" GC` 07/10/08
DRAWN 13Y: / I DAD
CJW
DATE DRAWN: 1 11/09/07 1
INFINIGY 1 202 -025
JOB NO:
SHEET TM-L'
SITE PLAN
SITE NUMBER:
ALBERMARLE COUNTY
SITE NAME:
BOYD
TAVERN
COUCH
SITE ADDRESS:
1641 BLACK CAT RD.
WICK- VA 22947
'I�LTH OF
)PHER J. WARREN
No. 037631
kls-io lNAl-
-
NOTES:
1. CIRCLE REPRESENTS RADIUS DISTANCE OF
APPROXIMATELY 2200' FROM THE TOWER LOCATION
�Olm wireless
1831 RADY COURT
RICHMOND, VA 23222
infinigy
e n g i n e e r i n g
2253 SEWaL MILL ROAD („V
SLATE 130
IoVRI A. CA 30062
TEL: 678.444.4483
FAX: VS-444-4472
WWW.INF*NCY.COM
THESE DRAWINGS AID /DR 111E IC MANYING SPECIFICATION
AS INSWMENTS OF SERVICE, ARE THE EX WE PROPERT
OF VMZDN WIRELESS AND THEIR USE AND PUBLICATION
SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH
THEY ARE PROM. REUSE. REPRODUCIDN OR PURICATIO
RT ANY 11E140D, N WHOLE OR N PMT, 5 PROHIWED
EXCEPT RY WARTEN PERILSSIDN FROM VERIZON WIRELESS.
TITLE TO THESE PLANS AND/OR SPECIFICATIONS SMALL
IBM WITH VER®N W1AIlf.SS WITHOUT PREJUDICE AND
VISUAL CONTACT WITH THEY SHALL CONSTITUTE PRIM FACIE
EVIDENCE OF ACCEPTANCE OF THESE 1E.SIDCn015.
REVISION
DESCIRNFIM BY DATE
A
ISSUED FOR REVIEW DAD 11/09/07
RE- LSAIED FOR REMEW CJW 02/29/08
RE -ISSUED FOR REVIEW GCF 07/10/08
i DRAWN BY: DAD
CJW
DATE DRAWN: 11/09/07
INnNIGY 202 -025
JOB NO:
SHEET TITLE:
RADIUS MAP
SITE NUMBER:
ALBERMARLE COUNTY
SITE NAME:
BOYD
TAVERN
COUCH
SITE ADDRESS:
1641 BLACK CAT RD.
KESWICK, VA 22947
1�11..Ln OFG
�f
PHER J. WARRED
No. 037631
to-08;��
NAL
SHEET
L 1LIM" ��' I REV. i
A
SURVEY NOTES:
1. THE BOUNDARY AS SHOWN ON THIS
MAP WAS PLOTTED FROM DEEDS.
2. THIS MAP DOES NOT MEET VIRGINIA STATE
STANDARDS FOR A BOUNDARY PLAT
J. THE SOLE PURPOSE OF THIS MAP IS TO
ESTABLISH A LEASE PARCEL FOR A CELLULAR
TELEPHONE INSTALLATION.
3. SUBJECT PROPERTY AS SHOWN IS
ALBEMARLE COUNTY TAX ID# 94 -34.
4. SUBJECT PROPERTY AS SHOWN DOES NOT FALL
WITHIN THE LIMITS OF A H.U.D. DESIGNATED FLOOD
HAZARD ZONE. THIS OPINION IS BASED UPON AN
INSPECTION OF THE FLOOD INSURANCE RATE MAPS
(COMMUNITY PANEL #51003C 0475D, ZONE X)
AND HAS NOT BEEN FIELD VERIFIED.
5. ALL OWNER AND TAX ID INFORMATION SHOWN
WAS OBTAINED FROM THE ALBEMARLE COUNTY
CIS WEBSITE. THIS SURVEYOR TAKES NO
RESPONSIBILITY FOR THE ACCURACY OF THIS
INFORMATION.
GRAPHIC SCALE
10' 0 10' 20'
N
-H
EXISTING PROPERTY LINE
TREES TO BE REMOVED
NUMBER SPECIES CALIPER CANOPY HEIGHT AGL HEIGHT
5 ASH 9' 482' AMSL ±37'
EXISTING 20" POPLAR TREE (2)
PROPOSED 12'
GRAVEL
PROPOSED
WOODEN FENN
CE Z8
EXISTING 21" OAK TREE (4)
PROPOSED TELCO PANEL
EXISTING 22" OAK TREE (3) PROPOSED METER
EXISTING 9" ASH TREE (5) 1 PROPOSED r - - - -- - - -- - - - -- -
TO BE REMOVED VERIZON 1DO'
Z3 MONOPOLE i
�— PROPOSED
VERIZON 50'x50'
LEASE AREA
4 I I PROPOSED
. _.�
VERIZON 26'x5O'
COMPOUND AREA
EXISTING PROPERTY LINE (- - --T
1
II
I
I
I
REFERENCE TREE
(28' OAK) (1) —
----- - - - - --
PROPOSED IL
Z8 DOUBLE GATE-
N 1 SITE LAYOUT
APPROX. NORTH
±s'
TREE INVENTORY
—
NUMBER
SPECIES
CALIPER
CANOPY HEIGHT
AGL HEIGHT
1
OAK
28'
535' AMSL
*90'
2
POPLAR
20'
532' AMSL
±100'
3
OAK
22'
516' AMSL
±76'
4
OAK
21'
520' AMSL
±80'
5
ASH
9'
482' AMSL
±37'
TREES TO BE REMOVED
NUMBER SPECIES CALIPER CANOPY HEIGHT AGL HEIGHT
5 ASH 9' 482' AMSL ±37'
EXISTING 20" POPLAR TREE (2)
PROPOSED 12'
GRAVEL
PROPOSED
WOODEN FENN
CE Z8
EXISTING 21" OAK TREE (4)
PROPOSED TELCO PANEL
EXISTING 22" OAK TREE (3) PROPOSED METER
EXISTING 9" ASH TREE (5) 1 PROPOSED r - - - -- - - -- - - - -- -
TO BE REMOVED VERIZON 1DO'
Z3 MONOPOLE i
�— PROPOSED
VERIZON 50'x50'
LEASE AREA
4 I I PROPOSED
. _.�
VERIZON 26'x5O'
COMPOUND AREA
EXISTING PROPERTY LINE (- - --T
1
II
I
I
I
REFERENCE TREE
(28' OAK) (1) —
----- - - - - --
PROPOSED IL
Z8 DOUBLE GATE-
N 1 SITE LAYOUT
APPROX. NORTH
±s'
±10'
t
PROPOSED SHELTER �1
12'x30' SHELTER Z7
l4
'
NOTE: PROPOSED VERIZON EQUIPMENT
SHELTER TO HAVE A DARK BROWN
AGGREGATE FACADE
*
PROPOSED GRAVEL
COMPOUND
- - - - --
- --
- --
IEgVILY WO Di , AREA WITH NU E
�6" TO 18' AL OAK TREES. TREES
r HG�FII,.AR Af�E TO BE REMO D OR
ve i On wireless
1831 RADY COURT
RICHMOND, VA 23722
jinfinigy
engi nee r ing�/
2255 SEWELL MILL ROAD ,�V
sun 130
MARIETTA, GA 30062
TEL 678.4444463
FAX: 678.444.4472
WWW.lNnNIGY.COM
TNSE DRwhw AND /00. THE ACCOIWWMC SPECIFICATION
AS 96TRUMM OF SER'ACC ARE THE EXCLUSNE P0.0PERI1
OF VUUM WREIESS AND THER USE AND PUBLICATION
%Wj BE RES1WM TO THE ORIGW SITE FOR WHICH
THEY ARE PREA WED, If= ROWDUMON OR PUBUCATTO
B! AHY MEnM R WMOLE OR IN PART, 6 PROHBITED
DWq BY WRITTEN PFRMSSION FROM VERQON WREIESS.
ME M THEE PLANS AND /OR 9'11RIGATIONS 91UL
REINYI WTN VF%ZON MKL SS WITHOUT PRENIDICE AND
VISUAL CONTACT WBH THEL S, 1 COFSTTTIE PRIM FAX
eInFNCE OF ACCEprAKE OF IHM R0RICTONS.
REVISION
NO. DESCRIPTION BY DATE
A I9i11ED FOR AEMEW DAD 11/09/07
B RE- ISSUED FOR REVIEW CJW 02/29/09
C RE -691ED FOR KWN GCF 07/10/09
DRAWN BY: DAD
CJW
DATE DRAWN: �11/09/07 INFINIGY
JOB N0:
SHEET TTTLE
LEASE AREA SITE
PLAN & LAYOUT
SITE NUMBER:
ALBERMARLE COUNTY
SITE NAME:
BOYD
TAVERN
COUCH
SITE ADDRESS:
1641 BLACK CAT RD.
KE K, VA 22947
r7A_
DPHER J.
No. 037631
0 —1 O —v `
� s'SIONALE�O
SHEET NUMBER: I REV. t
Z2 A
J
N
Q
.n
n
N %
w
i
W i j ri
w � '
d
0
\ liJl
REFERENCE TREE
(28" OAK)
TO DRIPLINE
GROUND ELEVATION AT BASE OF
PROPOSED TOWER: ±445.48 AMSL
±30'
±5'
J
N U-)
a �
.n
^a w
* Lu
w
O Z
w U
LD
z
S
1� z
O O
a
o
J O
w
In
0
o D_
I O
O 0_
J
Q
0
I
LIGHTNING ROD
MAX. TOP POLE DIAMETER
±545' AMSL TO TOP OF
— PROPOSED PROPOSED MONOPOLE
VERIZON ANTENNAS
PROPOSED FLUSH
MOUNT BRACKETS
PROPOSED MONOPOLE
PROPOSED 100'
MONOPOLE
NOTE PROPOSED VERIZON EQUIPMENT
SHELTER TO HAVE A DARK BROWN
AGGREGATE FACADE
PROPOSED
VERIZON PROPOSED
SHELTER FENCE (TYP.)
30* MAX BOTTOM POLE DIAMETER
MONOPOLE ELEVATION
-- NOT TO SCALE
PROPOSED PANEL
ANTENNA (TYP.)
(3 ANTENNAS AND TMA'S)
2 TYPICAL FLUSH MOUNT ANTENNA INSTALLATION
NOT TO SCALE
NOTE
ALL INFORMATION ON THIS PAGE IS PROVIDED BY VERIZON
WIRELESS AND / OR OTHERS AND IS SHOWN FOR ILLUSTRATIVE
PURPOSES ONLY. ANTENNA SHOWN IS TYPICAL AND MAY BE
REVISED PRIOR TO CONSTRUCTION
�ven-Z70,nr wireless
1831 RADY COURT
RICHMOND, VA 23222
i n f i n i g
engi nee r ing�/
2255 SEWELL MILL ROAD
SUITE 130
MARIETTA. GA 30062
TEL: 678.444 4463
FAX: 678.444.4472
WWW.INRNIGY.COM
TIME DRAAM AND/OR THE ACCOIWAMfDG SF�IChI N
AS D61 MOM OF SBENG£ ARE THE D(CIM PROPW
OF VEMZON MESS AND TIM USE AND PURUCATDN
SHALL BE RESIRCIED TO THE OW604AL SRE FOR WWH
THEY ARE PREPARED. REUSE. REPRODUCI N DR PUBIICATIO
8Y ANY IEEIFDD, RI OW OR H PART, 5 PROHIBITED
EXCEM BY WROTEII PfAY6QON FROM VERQON WIRELESS.
ME TO THESE RANS AD /OR SPFLIFIGTpl6 9WL
ROM WITH VERIZON WWEIFSS WIMOUI PREJUDICE AND
V6UAL CONTACT WITH 1HE11 SWAt C0115IIRIIE PRWN FACIE
EVIDENCE OF ACCEPTANCE OF THESE RESIPoCIIONS
REVISION
NO. DESCRIPTION BY DATE
A ISM FOR REVIEW OAD 11/03/07
B RE- IS5)ED FOR REVIEW CA 02/29/08
AE- ISSUED FOR RD" GOF 07/10/08
DRAWN BY: DAD
CJW
CHECKED BY:
DATE DRAWN: il/D9/07
INRNIGY 202 -025
JOB NO:
SHEET TITLE:
TOWER ELEVATION
AND DETAILS
SITE NUMBER:
ALBERMARLE COUNTY
SITE NAME:
BOYD
TAVERN
COUCH
SITE ADDRESS:
1641 BLACK CAT RD.
KESWICK, VA 22947
r -ALT f[ OF
Cuz HER J. WARREN
No. 037631
��SSjONAL ti 0
SHEET , D � - ... -I REV. /
Z 3 A
\ \ I
\ i
1
\ \ \ \ \ I EXISTING UTILITY
\ \ t POLE (TYP.)
\ r
I \
PROPOSED SILT FENCE
ZS
a \
EXISTING \
HOUSE � \
\
\ \'\ EXISTING WOODEN
\ \ STORAGE SHELTER
EXISTING \ \
DRIVE \
\
GRAPHIC SCALE
20' 0 20' 40'
LESSEE CENTERUNE OF 2
20' WIDE ACCESS / UTILITY
EASEMENT AND PROPOSED Z4
12' WIDE GRAVEL DRIVE
EXISTING— —
PROPERTY LINE REFER
(28" i
N GRADING, EROSION &
/--, SEDIMENT CONTROL PLAN
CALLED NORTH
FILL SLOPE (TYP.)
EXISTING GRADE
6- THICK ASTM C -33
#57 STONE GRAVEL
-N;;,► PROPOSED LESSEE 50x50'
O LEASE AREA (2,506± SQFT)
12'
DRIVEWAY SHOWN ON PLANS
3 -59,' -� —
MARAFl
STABILJZATION FABRIC
PLACED ON COMPACTED
SUBGRADE
3
COMPACTED SELECT COMPACTED SUBGRADE,
FILL WHERE REQUIRED FREE FROM TOPSOIL
(95% PROCTOR) AND ORGANICS
DRIVEWAY
2 SECTION — CROSS SLOPED
-- NOT TO SCALE
�017wlreless
1831 RADY COURT
RICHMOND, VA 23722
�i n f i n i gyp
e n g I n e e r inyY,
2255 SEWELL kl R01D (0
SUFTE 130
MARIETTA, GA 30082
MT 678 444.4463
FAX: 878.444.4472
WWW.INFINW.COM
THESE DRAMAIGS MEQR THE ACCOMPWM SPEXICATON
AS INS"ENR OF SERVICE. ARE THE EXCLUSIVE PROPERII
OF VSVON WIRELESS AND THEIR USE YID RMCITON
SHALL BE RESTRICTED TO THE DIORAL SITE FOR WHICH
THEY ARE PREPARED. REOSE REPRODUCTON OR PIR D7O
Bf ANY METHOD. N WHOLE OR N PART, S PRWWED
E %CEP± BY WRITTEN PEPoSSION FROM VEAQDN WViELESS.
TITLE TO THESE PUNS AND /OR SPECIFICATIONS SINLL
REMAIN WITH YMON VAE7.ESS WTIHDIIT PREJUDICE AND
VMK CONTACT WITH THEY SHALL CONSUME MINA FACE
EVIDENCE OF ACCE ANA OF THESE RFSRRICII01S-
DESCIiIFn0N BY DAIS
A 651kD FOR REVIEW DAD 11/09/07
RE -MMED FOR REVIEW CJW 02/29/08
RE-ISM FOR REVIEW GCF 07/10/08
DRAWN BY: DAD
CJW
DATE DRAWN: 11/09/07
INFINIGY 202 -025
JOB NO:
SHEET TITLE
GRADING, EROSION
& SEDIMENT
CONTROL PLAN
SrI-E NUMBER:
ALBERMARLE COUNTY
SfTE NAME:
BOYD
TAVERN
COUCH
SITE ADDRESS:
1641 BLACK CAT RD.
KESWICK, VA 22947
H of
SPHER J. WARR
No. 037631
-jr �Kl��S—SION . Al,
SHUT u4 ...T, � IfE1/. A
GRADING & EXCAVATING NOTES:
1. ALL EXCAVATIONS ON WHICH CONCRETE IS TO BE PLACED SHALL BE SUBSTANTIALLY
HORIZONTAL ON UNDISTURBED AND UNFROZEN SOIL AND BE FREE FROM LOOSE
MATERIAL AND EXCESS GROUNDWATER. DEWATERING FOR EXCESS GROUNDWATER
SHALL BE PROVIDED IF REQUIRED.
2. CONCRETE FOUNDATIONS SHALL NOT BE PLACED ON ORGANIC MATERIAL. IF SOUND
SOIL IS NOT REACHED AT THE DESIGNATED EXCAVATION DEPTH, THE
UNSATISFACTORY SOIL SHALL BE EXCAVATED TO ITS FULL DEPTH AND EITHER BE
REPLACED WITH MECHANICALLY COMPACTED GRANULAR MATERIAL OR THE
EXCAVATION BE FILLED WITH CONCRETE OF THE SAME QUALITY SPECIFIED FOR THE
FOUNDATION.
3. ANY EXCAVATION OVER THE REQUIRED DEPTH SHALL BE FILLED WITH EITHER
MECHANICALLY COMPACTED GRANULAR MATERIAL OR CONCRETE OF THE SAME
QUALITY SPECIFIED FOR THE FOUNDATION. CRUSHED STONE MAY BE USED TO
STABILIZE THE BOTTOM OF THE EXCAVATION. STONE, IF USED, SHALL NOT BE USED
AS COMPIUNG CONCRETE THICKNESS.
4. AFTER COMPLETION OF THE FOUNDATION AND OTHER CONSTRUCTION BELOW
GRADE, AND BEFORE BACKFIWNG, ALL EXCAVATIONS SHALL BE CLEAN OF
UNSUITABLE MATERIAL SUCH AS VEGETATION, TRASH, DEBRIS, AND SO FORTH
FOR ANY FWNG OPERATION.
S. REMOVE ALL VEGETATION, TOPSOIL, DEBRIS, WET AND UNSATISFACTORY SOIL
MATERIALS, OBSTRUCTIONS, AND DELETERIOUS MATERIALS FROM GROUND SURFACE
PRIOR TO PLACING FILLS. PLOW, STRIP, OR BREAK UP SLOPED SURFACES STEEPER THAN
THAN 1 VERTICAL TO 4 HORIZONTAL SO FILL MATERIAL WILL BOND WITH EXISTING SURFACE.
WHEN SUBGRADE OR EXISTING GROUND SURFACE TO RECEIVE FILL HAS A DENSITY LESS
THAN THAT REQUIRED FOR FILL, BREAK UP GROUND SURFACE TO DEPTH REQUIRED,
PULVERIZE, MOISTURE — CONDITION OR AERATE SOIL AND RECOMPACT TO REQUIRED
DENSITY.
6. —USE APPROVED MATERIALS CONSISTING OF EARTH, LOAM, SANDY CLAY, SAND
—BE FREE FROM CLODS OR STONES OVER 2 -1/2" MAXIMUM DIMENSIONS
—BE PLACED IN 6" LAYERS AND COMPACTED TO 95% STANDARD PROCTOR
EXCEPT IN GRASSED /LANDSCAPED AREAS, WHERE 90% STANDARD PROCTOR
7. REPLACE EXISTING GRAVEL SURFACING ON AREAS FROM WHICH GRAVEL SURFACING IS
REMOVED DURING CONSTRUCTION OPERATIONS. GRAVEL SURFACING SHALL BE REPLACED
TO MATCH EXISTING ADJACENT GRAVEL SURFACING AND SHALL BE OF THE SAME
THICKNESS. SURFACES OF GRAVEL SURFACING SHALL BE FREE FROM CORRUGATIONS AND WAVES.
EXISTING GRAVEL SURFACING MAY BE EXCAVATED SEPARATELY AND REUSED IF INJURIOUS
AMOUNTS OF EARTH, ORGANIC MATTER, OR OTHER DELETERIOUS MATERIALS ARE REMOVED
PRIOR TO REUSE. FURNISH ALL ADDITIONAL GRAVEL RESURFACING MATERIAL AS REQUIRED.
BEFORE GRAVEL SURFACING IS REPLACED, SUBGRADE SHALL BE GRADED TO CONFORM TO
REQUIRED SUBGRADE ELEVATIONS, AND LOOSE OR DISTURBED MATERIALS SHALL BE THOROUGHLY
COMPACTED. DEPRESSIONS IN THE SUBGRADE SHALL BE FILLED AND COMPACTED WITH
APPROVED SELECTED MATERIAL. GRAVEL SURFACING MATERIAL MAY BE USED
FOR FILUNG DEPRESSIONS IN THE SUBGRADE, SUBJECT TO ENGINEER'S APPROVAL.
8. DAMAGE TO EXISTING STRUCTURES AND UTIUTIES RESULTING FROM CONTRACTOR'S NEGLIGENCE
SHALL BE REPAIRED /REPLACED TO OWNER'S SATISFACTION AT CONTRACTOR'S EXPENSE.
9. CONTRACTOR SHALL COORDINATE THE CONSTRUCTION SCHEDULE WITH PROPERTY OWNER SO AS
TO AVOID INTERRUPTIONS TO PROPERTY OWNER'S OPERATIONS.
10. ENSURE POSITIVE DRAINAGE DURING AND AFTER COMPLETION OF CONSTRUCTION.
11. ALL CUT AND FILL SLOPES SHALL BE MAXIMUM 3 HORIZONTAL TO 1 VERTICAL.
12. CONTRACTOR SHALL BE RESPONSIBLE FOR MONITORING SITE VEHICLE
TRAFFIC AS TO NOT ALLOW VEHICLES LEAVING THE SITE TO TRACK
MUD ONTO PUBLIC STREETS. THE CONTRACTOR IS RESPONSIBLE
FOR CLEANING PUBLIC STREETS DUE TO MUDDY VEHICLES LEAVING
THE SITE.
GENERAL EROSION & SEDIMENT CONTROL NOTES:
1. THE SOIL EROSION AND SEDIMENT CONTROL MEASURES AND DETAILS AS SHOWN
HERIN AND STIPULATED WITHN STATE STANDARDS
SHALL BE FOLLOWED AND INSTALLED IN A MANNER SO AS TO
MINIMIZE SEDIMENT LEAVING THE SITE.
2. PRIOR TO COMMENCING LAND DISTURBANCE ACTIVITY, THE
LIMITS OF LAND DISTURBANCE SHAH BE CLEARLY AND
ACCURATELY DEMARCATED WITH STAKES, RIBBONS, OR
OTHER APPROPRIATE MEANS.
3. EROSION CONTROL DEVICES SHALL BE INSTALLED BEFORE GROUND
DISTURBANCE OCCURS. THE LOCATION OF SOME OF THE EROSION
CONTROL DEVICES MAY HAVE TO BE ALTERED FROM THOSE SHOWN ON THE
APPROVED PLANS IF DRAINAGE PATTERNS DURING CONSTRUCTION ARE
DIFFERENT FROM THE FINAL PROPOSED DRAINAGE PATTERNS. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO ACCOMPUSH EROSION CONTROL FOR
ALL DRAINAGE PATTERNS CREATED AT VARIOUS STAGES DURING CONSTRUCTION.
ANY DIFFICULTY IN CONTROLLING EROSION DURING ANY PHASE OF
CONSTRUCTION SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY.
4. THE LOCATION OF SOME OF THE EROSION CONTROL DEVICES
MAY HAVE TO BE ALTERED FROM THAT SHOWN ON THE
PLANS IF DRAINAGE PATTERNS DURING CONSTRUCTION ARE
DIFFERENT FROM THE FINAL PROPOSED DRAINAGE PATTERNS.
ANY DIFFICULTY IN CONTROWNG EROSION DURING ANY PHASE
OF CONSTRUCTION SHALL BE REPORTED TO THE ENGINEER
IMMEDIATELY.
5. CONTRACTOR SHALL MAINTAIN ALL EROSION CONTROL MEASURES UNTIL
PERMANENT VEGETATION HAS BEEN ESTABUSHED. CONTRACTOR SHALL
CLEAN OUT ALL SEDIMENT PONDS WHEN REQUIRED BY THE ENGINEER OR
C
THE LOCAL JURISDICTION INSPECTOR. CONTRACTOR SHA LL INSPECT EROSION
CONTROL MEASURES AT THE END OF EACH WORKING DAY TO ENSURE
MEASURES ARE FUNCTIONING PROPERLY.
S. THE CONTRACTOR SHALL REMOVE ACCUMULATED SILT WHEN
THE SILT IS WITHIN 12" OF THE TOP OF THE SILT FENCE.
7. FAILURE TO INSTALL, OPERATE OR MAINTAIN ALL EROSION
CONTROL MEASURES WILL RESULT IN ALL CONSTRUCTION
BEING STOPPED ON THE JOB SITE UNTIL SUCH MEASURES ARE
CORRECTED.
B. SILT BARRIERS TO BE PLACED AT DOWNSTREAM TOE OF ALL
CUT AND FILL SLOPES.
9. ALL CUT AND FILL SLOPES MUST BE SURFACED ROUGHENED AND
VEGETATED WITHIN SEVEN (7) DAYS OF THEIR CONSTRUCTION.
10. CONTRACTOR SHALL REMOVE ALL EROSION & SEDIMENT CONTROL
MEASURES AFTER COMPLETION OF CONSTRUCTION AND
ESTABUSHMENT OF PERMANENT GROUND COVER.
11. THE ESCAPE OF SEDIMENT FROM THE SITE
SHALL BE PREVENTED BY THE INSTALLATION OF EROSION CONTROL
MEASURES AND PRACTICES PRIOR TO, OR CONCURRENT WITH,
LAND— DISTURBING ACTIVITIES.
FERTILIZER MIX
APPLICATION
N, # /ACRE
P2 Q., # /ACRE
K20, # /ACRE
N, TOP DRESSING
1st
60 — 90
120 — 180
120 — 180
50
2nd
60
120
120
—
NOTE:
— GRASS AND MULCH ALL DISTURBED AREAS
WHEN HYDRAUUC SEEDING AND FERTILIZING EQUIPMENT IS USED, NO GRADING AND SHAPING OR
SEEDBED PREPARATION WILL BE REQUIRED. THE FERTILIZER, SEED AND WOOD CELLULOSE FIBER
MULCH WILL BE MIXED WITH WATER AND APPUED IN A SLURRY. ALL SLURRY INGREDIENTS MUST
BE COMBINED TO FORM A HOMOGENEOUS MIXTURE, AND SPREAD UNIFORMLY OVER THE AREA
WITHIN ONE HOUR AFTER MIXTURE IS MADE. STRAW OR MAY MULCH AND ASPHALT EMULSION
WILL BE APPUED WITH BLOWER —TYPE MULCH SPREADING EQUIPMENT WITHIN 24 HOURS AFTER
SEEDING, THE MULCH WILL BE SPREAD UNIFORMLY OVER THE AREA, LEAVING ABOUT 25
PERCENT OF THE GROUND SURFACE EXPOSED.
GRADE, SHAPE AND SMOOTH WHERE NEEDED TO PROVIDE FOR SAFE EQUIPMENT OPERATION AT
SEEDING TIME AND FOR MAINTENANCE PURPOSES. THE UME AND FERTILIZER IN DRY FORM WILL
BE SPREAD UNIFORMLY OVER THE AREA IMMEDIATELY BEFORE SEEDBED PREPARATION. A
SEEDBED WILL BE PREPARED BY SCARIFYING TO A DEPTH OF 1 TO 4 INCHES AS DETERMINED
ON SITE. THE SEEDBED MUST BE WELL PULVERIZED, SMOOTHED AND FIRMED. SEEDING WILL
BE DONE WITH CULTIPACKER— SEEDER, DRILL, ROTARY SEEDER OR OTHER MECHANICAL OR HAND
SEEDER. SEED WILL BE DISTRIBUTED UNIFORMLY OVER A FRESHLY PREPARED SEEDBED AND
COVERED UGHTLY. WITHIN 24 HOURS AFTER SEEDING, STRAW OR HAY MULCH WILL BE SPREAD
UNIFORMLY OVER THE AREA, LEADING ABOUT 25 PERCENT OF THE GROUND SURFACE EXPOSED.
MULCH WILL BE SPREAD WITH BLOWER —TYPE MULCH EQUIPMENT OR BY HAND AND ANCHORED
IMMEDIATELY AFTER IT IS SPREAD. A DISK HARROW WITH THE DISK SET STRAIGHT OR A SPECIAL
PACKER DISK MAY BE USED TO PRESS THE MULCH INTO THE SOIL
WOVEN WIRE FENCE
(MIN. 14 1/2 GAUGE
W/ MAX. 6" MESH
SPACING)
10' MAX. C. TO C.
36" MIN. LENGTH FENCE
POSTS DRIVEN MIN. 16"
INTO GROUND.
:J�EIGHT OF FILTER
.✓ W W W —j'. `N..` 16" MIN.
y W W W W
PERSPECTIVE VIEW
8' MIN.
36" MIN. FENCE POST —�
WOVEN WIRE FENCE (MIN. 14 1/2
GAUGE MAX. 6" MESH \I�
SPACING ) WITH FILTER CLOTH FLOW z
CONSTRUCTION SPECIFICATIONS
1. WOVEN WIRE FENCE TO BE FASTENED SECURELY TO FENCE POSTS WITH WIRE TIES
OR STAPLES. POSTS SHALL BE STEEL EITHER "T" OR U" TYPE OR HARDWOOD.
2. FILTER CLOTH TO BE TO BE FASTENED SECURELY TO WOVEN WIRE
FENCE WITH TIES SPACED EVERY 24 AT TOP AND" MID SECTION.
FENCE SHALL BE WOVEN WIRE, 12 1 2 GAUGE, 6 MAXIMUM MESH OPENING.
3. LAPPED BYSSIX�INCHESFAND FOLDED H ADJOIN CLOTH FL SHALL BE EITHERLFILLTER OVER-
LAPPED 100X, STABIUNKA T140N, OR APPROVED EQUIVALENT.
4. PREFABRICATED UNITS SHALL BE GEOFAB, ENVIROFENCE, OR APPROVED EQUIVALENT.
5. MAINTENANCE SHALL BE PERFORMED AS NEEDED AND MATERIAL REMOVED WHEN
"BULGES" DEVELOP IN THE SILT FENCE.
COMPACTED
EMBED FILTER CLOTH
A MIN. OF 6" IN GR01
16" MIN.
SECTION VIEW
1 SILT FENCE DETAIL
-- NOT TO SCALE
UNDISTURBED GROUND
�verl_270nj wire%sS
1831 RADY COURT
RICHMOND, VA 23222
linfe rin
e
e n g in e e r i n g
2255 SEWELL WILL ROAD
SURE 130
MW&TM GA 30062
TEL- 670.444.4463
FAX: 678.444.4472
11IWWJNRmcf.CDM
THESE DRAWNCS AND /DR RE ACCOI MND SPECMATIDN
AS MMMENi5 OF SEIKE, ARE RE DICLUSNE PNPERf
OF VUMN WDELESS AID DO USE AND RarATION
MALL BE RESTRICTED TO THE OW AL SIZE FOR WF404
THEY ARE PREPARED. REUSE, REPRODUCTION OR PUMT10
Bf ANY METHOD, N WHOLE OR N PARE, 6 PRdRTED
EXCEPT Bf WRITTEN PUMMON FROM VMMN WNDi1S
TITLE TO THESE PLANS AND/OR SPEEYFIUATIOKS SHHL
RD" WHH MERIZDN WEEESE WITHOUT PREIIME AND
VSUAL CONTACT WRH THEN STALL CONSM ITE PRWW FACE
EVIDENCE OF ACCEPF M OF THESE RESTRICTIONS
REVISION
OESCRIPION BY DATE
A ISM FOR REVEW DAD 11/09/07
RE-ISM FOR REWEW tM 02 /29/06
GCF 07 I1 0
- 1591ED FOR AEVEW N6
DRAWN OY: / I DAD
cJW
DATE DRAWN: 1 11/09/07 1
MNIGY 1 202 -025 I
JOB NO:
—SHEET Trrm-
GRADING, EROSION
& SEDIMENT
CONTROL NOTES
SITE NUMBER:
ALBERMARLE COUNTY
SITE NAME:
BOYD
TAVERN
COUCH
SITE ADDRESS:
1641 BLACK CAT RD.
KESWICK, VA 22947
OPHER ). WARREN
No. 037631
S" z5f A I
MONOPOLE
2' -0" 1
HOLES
1 WAVEGUIDE BRIDGE DETAIL
NOT TO SCALE
43 ISOMETRIC WAVEGUIDE BRIDGE
NOT TO SCALE
VALMONT MICROFL
UNIVERSAL PIPE A
KIT PART NO. B1:
WAVEGUIDE
PIPE POST
PROPOSED 2 -POLE WAVEGUIDE
BRIDGE
3 1/2" O.D. x 15' -0" SUPPORT PIPE
(CUT AS NECESSARY) EMBEDDED IN
CONCRETE. INSTALLED PER MFG'S
INSTRUCTIONS.
- CONCRETE FOOTING (TYP)
2 SECTION VIEW
NOT TO SCALE
6" #1 OR #2 STONE OR EQUAL
TO EXISTING COMPOUND
CPS ANTENNA
1" 0 DIAMETER SCHEDULE 40 RIGID
GALVANIZED STEEL PIPE, 24" LONG
4 CPS ANTENNA MOUNT
NOT TO SCALE
ve rr Ola wireless
1831 RADY COURT
RICHMOND, VA 23222
infinigy
e n g i nee r ing�/
2255 SEWELL MILL ROAD (�V
SURE 130
WJBETTA GA 30082
TEL: 678.444.4463
FAX 678 444 4472
YAWW.N vwf.COY
THESE DAAWNOS AND/OR THE ACCOMPW" SPED19CATON
AS KSTRINEMS OF SERVICE ARE THE EXCLISNE PROPERr
OF VDL20N WWiRM AND THEIR USE AND R UGTDN
SINL BE RESTRICTED TO THE DRXANAL SUE FOR WHICH
THEY ARE PREPARED. REUSE. RFPRODUCDON OR PUBIJOITID
BY ANY WEM. N WHOFE DR N PART, 6 PROHBIlEO
EXCEPT BY WREN P09I014 FROM VERIZON WIRELESS.
TIRE TO THESE KAM AND /OR SPECMTM 9NL
ROM WITH VM N WfaM WOHOUT PREJUDICE AND
VBUAL CONTACT WDH TFE11 SFNLL CON5117M PMA FACE
EVIDENCE OF ACCEPTANCE OF THESE RESIPoCFIDNS.
REVISION
DESCRIPTION BY DATE
A ISSUED FOR REWW DAD 11/09/07
RE -MUED FOR REWW GM 02/29/08
RE -MUED FOR RENEW GCF 07/10/08
=BIY: DAD CJW
DATE DRAWN: 11/09/07
INFINIGY 202 -025
JOB NO:
SHEET TILE:
WAVEGUIDE
BRIDGE DETAILS
SITE NUMBER:
ALBERMARLE COUNTY
SITE NAME:
BOYD
TAVERN
COUCH
SITE ADDRESS:
1641 BLACK CAT RD.
KESWICK, V 22947
X015 �I.TH Op I�
V
O_` ry
U �
CH PHER J. NVARRa
No. 037631
10 -O la
1
�SSIONAI
SHEET NUMBER:
Z6 a
3' -5 %"
REAR WALL ELEVATION C
NOT TO SCALE
MOTION SENSITIVE
OUTDOOR LIGHT-
4'- 117%"
33' -2'
s' -539'
FOR CABLE
CONFIGURATION
(SEE DETAIL BELOW)
3' -9
30'
FRONT WALL ELEVATION A
NOT TO SCALE
PRE -FAB BUILDING WAS DESIGNED BY OTHERS AND DRAWINGS
WERE PROVIDED AS PART OF VERIZON WIRELESS STANDARD DETAILS.
REFER TO 11' -7" x 30'x 10' -7" CONCRETE SHELTER DRAWINGS
(MODEL #2685) BY VFP, INC. FOR SPECIFIC INFORMATION.
6
13' -3'
DARK BROWN AGGREGATE
FACADE
5' -10
-, TYPICAL SHELTER ELEVATIONS
\L___1 NOT TO SCALE
NOTE:
INFORMATION CONTAINED IN THESE DRAWINGS REFERRING TO THE PROPOSED
VERIZON EQUIPMENT SHELTER WERE OBTAINED FROM STANDARD EQUPIMENT
SHELTER DRAWINGS PROVIDED BY VERIZON. THE INFORMATION CONTAINED IN
THESE PLANS SHOULD BE CONSIDERED AS A GUIDE AND CONTRACTOR IS
SPECIFICALLY DIRECTED TO OBTAIN AND USE THE SHELTER DRAWINGS PROVIDED
BY VERIZON SPECIFIC TO THIS SITE.
TYPICAL WALL LAYOUT:
C
B D
A
�v�e_r&70,lrpwlreless
1831 RADY COURT
RICHMOND, VA 23222
infinigy
e n g i n e e r ing__/
2255 SEWELL MILL ROAD (gyp
SUITE 130
MARIE7A, GA 30062
TEL: 678.444 4463
FAX: 678.444-4472
WWW.INFINIGY.COM
THESE DRAWINGS AD/0R THE ACCOIWANYIIO SPEDIPIGINN
AS INSTRUMENTS OF SERVICE, ARE THE DXLLISME PROPEL"
OF VERQDII WIRELESS AND THEIR USE AND PUMICA IDN
ZU BE FZjW ED TO THE DMIAL SITE FOR WHICH
TIEY ARE PREPARED. REUSE. RTROOLICIDN OR PUB ,1CA TION
BY ANT' LE7HDD. W WHITE DR IT PART, IS PROHNIM
DWI Of WRIFIEN PONSSION FROM VFRQON WIRELESS,
TITLE TO THESE PLANS AND /OR SPEDFIGTIONS SHWE
REIM WITH VWDN WWDESS MITIOLIT PREI1DIi AND
VISUAL CONTACT WITH THEY SHALL CONSIfME PIMA FACE
EVIDENCE OF ACCEPTANCE OF IIESE RE4IRICTIDI6.
REVISION
N DESCRIPnON BY DATE
q ISSUED FOR REVIEW DAD 11/09/07
RE -ISM FOR REVIEW OFW 02/79/08
RE- ISSUED FOR REVIEW CCF 07/10/06
BY:
DAD
[DRAWN
CHECKED BY:
CJW
DATE DRAWN:
11/09/07
INFINIGY
202 -025
JOB NO:
SHEET TrrLE
SHELTER ELEVATIONS
SFFE NUMBER:
ALBERMARLE COUNTY
SITE NAME:
BOYD
TAVERN
COUCH
SITE ADDRESS:
1641 BLACK CAT RD.
KESWICK, VA 22947
EP+LTN OF
L
O
U
STOPHER J. WARRE
No. 037631
1-6�O
0
SSIONAL
SHEET NUMBER:
REV. I
Z7
I A
f
3" X 3/4" CEDAR PICKETS WITH
DOG EAR STYLE BOARD TREATMENT
r
L
i7
2" X 3" PRESSURE
TREATED RAILS
(3 PER SECTION) Zl— 4" X 4" X 8' PRESSURE
TREATED POSTS (TYP)
I
J
r J PROVIDE ALUMINUM
SCREW TYPE NAILS
1l (3 PER PICKET)
h
r I FINISHED GRADE
L
/I I
8' C —C MAX. SPACING I I 2' -6"
1 I
I I I
CONCRETE IL I I
FOOTING (TYP) _J L_J
�
�CEDAR STOCKADE FENCE DETAIL (DOG EAR— STYLE)
NOT TO SCALE
NOTE: PAINT OR STAIN ENTIRE FENCE, INSIDE & OUT.
SITE OWNER TO SELECT TYPE & COLOR
3" X 3/4" CEDAR OR PRESSURE
TREATED LUMBER. DOG EAR STYLE
BOARD END TREATMENT.
n
rq
INSTALL REVERSABLE HINGE LOCK
PLATE WITH PADLOCK
� cV
r
2" X 3" CEDAR BACKING RAIL OR
2" X 4" PRESSURE TREATED BACKERS.
BOX FRAME AND CROSS BRACE EACH GATE
SECTION. MITRE BRACE ENDS TO FIT SNUG.
L ' THREADED EYEBOLT. ATTACH 1/8" CABLE FROM
GATE TO POST. (TYP BOTH SIDES).
5" X 5" SQUARE
-- - PRESSURE TREATED POST
i
\ / PROVIDE ALUMINUM
\ \ / SCREW TYPE NAILS
\
i (3 PER EACH BRACE END)
/ / \ 4" X B" GALV. STEEL HINGE.
/ \ FASTEN WITH SEVEN
1 -7/8" SCREWS (TYP FOR
'ET111-H
EACH HINGE)
14" X 4" SQUARE
I IPRESSURE TREATED' I ("
FINISHED I
NTH 48"
SET IN LINE j
GRADE N
I I WITH GATE P, STS. I 1
I(BACK OF GA—,
L_J
12' GATE OPENING
\BOARD STYLE SWING GATE —DOG EAR STYLE (12' WIDE)
NOT TO SCALE
6" J57 STONE OR EQUIVALENT
ON STABILIZATION FABRIC
GRADE TO DRAIN AS
SHOWN ON PLAN---7
WOODEN FENCE
LIMITS OF CRUSHED
STONE SURFACE
�- 2" x 6" PRESSURE
TREATED WOOD CURB.
GRADE TO DRAIN
YARD FROM TOWER
2" x 4" x 1' -6" LONG
PRESERVATIVE PRESSURE
TREATED WOOD STAKE AT
MARAFl
STABILIZATION FABRIC 5' -0" O.C.
PLACED ON COMPACTED wl
SUBGRADE
3 SECTION THROUGH COMPOUND
NOT TO SCALE
�017
wireless
1831 RADY COURT
RICHMOND, VA 23222
i n f i n i a
e n g i n e e r i n g
2255 SEWELL MILL ROAD
SUITE 130
WPoETTi. GA 30002
TEL: 678.444.4453
FAX.- 678.444.4472
www.INFDwy.COM
THESE DRAWNGS AND /DR THE � SPEpnfATMN
AS *GTRVAM OF sEAVItE, ARE THE D CWSNE PROPEmY
OF VMDN WFaM AND TIfIR USE AND PUBLIGITION
ski BE RFSIR= TO TILE OWML WE FOR WHICH
THEY ARE PRUMM. RELSE, REPRODICipN OR RRXATIDN
BI ANY MUM, IN WHOLE OR IN PART, IS PROHIIM
EXCEPT af PE �
1H� %I ALL
m" WEER VEFNLOIE WNIE m WIRIDUT PfE,Rm AND
WISLIk CMACT WITH THEN MALI CONS MITE FRtW FACE
DIDDa OF ACCEPTANCE OF TM RESTRETIO LS
REVISION
DESCRIP110N RY DATE
q ISM FOR REVETI' DAD 11/09/07
RE- LSSUED FOR REwM CJW o2/29/OB
RE- 1S91ED FOR REVEW (CF' 07/10/08
DRAW>B
MD
CHECKED BY:
CJW
DATE DRAWN:
11/09/07
INFINIGY
202 -025
JOB NO:
SHEET TITLE:
FENCE DETAILS
SITE NUMBER:
ALBERMARLE COUNTY
SITE NAME:
BOYD
TAVERN
COUCH
SrrE ADDRESS:
1641 BLACK CAT RD.
KESWICK, VA 22947
I.TH OF
. 0
STOPHER J. WARREN
No. 037631
4'
w
O��SSZONAl-V-
SHM NUMBER;
REV, #
Z8
A
Map is for display purposes only • Aerial Imagery from Commonwealth of Virginia
Attachment B
._. j' yyaSS
11
AC
411
j
9
4. p,,j
r - .
vw l
wr -
a
Wf
Page I of 1
Gerald Gatobu
From: Margaret Maliszewski
Sent: Thursday, July 03, 2008 3:24 PM
To: 'Stephen Waller'
Cc: Gerald Gatobu
Subject: RE: SDP 08 -097 Couch Property / Verizon Wireless Tier II PWSF ( "Boyd Tavern ")
Stephen,
You are right. The property (94 -34) is not adjacent to the Entrance Corridor and only the southwest corner of the
parcel falls within 500' of the EC. Consequently, the proposal does not require ARB review. I'm sorry for the
confusion.
Margaret
From: Stephen Waller [mailto:stephen .wailer @wirelessresources.com]
Sent: Thursday, July 03, 2008 3:01 PM
To: Margaret Maliszewski
Cc: Gerald Gatobu; Sipe, Maynard L.
Subject: SDP 08 -097 Couch Property / Verizon Wireless Tier II PWSF ( "Boyd Tavern ")
Hello Margaret,
Per our conversations yesterday and last week while Gerald and I were performing the balloon test at this site last
week, I just wanted to confirm that ARB approval will not be required for this site. Your original site review
comments from June 16th state that the site is located within the Entrance Corridor Overlay District, because the
southwestern tip is right around the 500 -foot mark. However, upon a closer look we saw that the site is self is
nearly 900 feet away from Route 250 and the test balloon was not visible from Route 250 and therefore ARB
review will not be required.
If you agree with this assessment please respond with a brief affirmation at your earliest convenience.
Thanks,
Steve
Stephen Waller, AICP
Site Development Consultant
Wireless Resources
(434)825- 0617(C)
(757)282- 5811(F)
stephen .wailer @wirelessresources.com
NOTICE: This communication from Wireless Resources Inc., including attachments, if any, is intended as a
confidential and privileged communication. If received in error, you should not copy, save or reproduce in any
manner or form, but delete immediately and notify the sender.
Attachment D
8/5/2008